Loading...
HomeMy WebLinkAbout217540-1d Compaction signedHeadquarters 1W C IL � ENGINEERING Mailing 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958 1 %% AND TESTING Sebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.# 5693 Sanford, FL. 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net DATE TESTED: September 20, 2021 KSM JOB #: 217540-1d/MR/jam NUC # 276 PERMIT #: 2108-0274 Nuc Model: MC -DR Nuc Serial #: MD40107276 CONTRACTOR: VB Custom Homes JOB LOCATION: 159 Ocean Estate Drive Fort Pierce, Florida ITEM TESTED: Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1 N.E. 0" - 12" 55+ 111.8 113.2 98.8% 2 N.W. 1 112.5 " 99.4% 3 Center 1 112.0 " 98.9% 4 S.E. 1 110.6 " 97.7% 5 S.W. 1 111.3 " 98.3% Soil Description: Light Brown Sand with Silt and Shell Fragments In Place Moisture: 10.8 % Proctor Optimum Moisture: 12.0 % Proctor Max. Dry Density: P.C.F. 113.2 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Staked Foundation Respectfully Submitted: Digitally signed by thisitemha=b— electronicallysigned Julie Keller sealetl by Julle Keller, F.E. FL L1c. 68366 an the date stated direttly to the right using a fhlz dlgltalslgnuDate: n[ed pies, copiof document are no[ nsid and the a nd sealed the =,gnaturemurtheyeri,iedo a yelectro is 2021.09.21 [°pies. 12::53:17 Julie E. Keller, P.E.QPreesiident PE# 68366 9/21/2021 Email to: pattycollinsvb@gmail.com 115.0 W E114.0 J—..�.._.._..—.._,._..�..�.._.._.._ I I I I I I I I I I I I I I � G I 113.0 H I I I I I T 112.0 t—•.J.._.I_..J— _I._..L..J.. I_.._ P I I I I I 111.0 �..�.._.I_ .+.._I._..�..�.._.I_.._ C I I I I I I F 110.0 y.. �_..t.._I._..1--..-1.._.I_.._ 109.0 i..1.._.i_..T.._I._..�..�.._.i_.._ I I I I I I D R 108.0..�.._.i_..t.._i._..�..�.._.i_..� I I I I I I I Y 7 8 9 10 11 12 13 14 15 Moisture - % of Dry Weight Disclaimer: Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE