HomeMy WebLinkAboutCOMPACTION211;a / �� ,Soil Density
r
- _ °.��, Associates, Inc Nuclear Gauge
Permit # 2103.0474
Port Lucie Branch
Report Date: 09/20/2021
FloridaRegistration No. 5950
460 NW Concourse Place, unit 1
Test Method: ASTM D6938
Port St. Lucie, FL 34986
Phone:772.878-0072
Client: Project:
Renar Development Corp. 113-15-66-5434B
3725 S. East Ocean Boulevard, Suite 101 Momingside Residential Lots
Stuart, FL 34996 Fort Pierce
Fort Pierce, FL
Test Results
Maximum
In Place
In Place
Optimum
Dry
In Place
Dry
Wet
Probe
Test #
Retest
Of
Test Date
Proctor lD
Method
Soil
Classification
Moisture
%)
Density (pcf)
Moisture
%
Density
Density
(pcf)
Depth
Percent
Min Comp.
505
09/13/21
21-181
B
—
11.5
112.0
12.0
p
109.2
122.3
(in)
12
Compaction
98
(%)
95
Remark
Pass
Modified
506
09/13/21
21-181
B
—
11.5
112.0
10.6
111.1
122.9
12
99
95
Pass
(Modified)
507
09/13/21
21-181
B
—
11.5
112.0
8.9
110.5
120.3
12
99
95
Pass
(Modified
508
09/13/21
21-181
B
—
11.5
112.0
10.2
109.8
121.0
12
98
95
Pass
Modified
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model I SN / Calibrated
Field Technician
505
Building Pad: Lot 87, 9767 Palm Breezes Drive. North Side of House Pad, Center
-1.0
Top of Pad
Troxler/ T-3430 / 21330 /
Tech, Port St. Lucie
506
Building Pad: Lot 87,9767 Palm Breezes Drive. South Side of House Pad, Center
-1.0
Top of Pad
Troxler/ T-3430 / 21330 /
Tech, Port St. Lucie
507
Building Pad: Lot 87, 9767 Palm Breezes Drive. East Side Footing Pad, Center
-1.0
Top of Pad
Troxler/ T-3430 / 21330 /
Tech, Port St. Lucie
508
Building Pad: Lot 87, 9767 Palm Breezes Drive. West Side Footing Pad, Center
-1.0
Top of Pad
Troxler/ T-3430 / 21330 /
Tech, Port St. Lucie
Remarks
Comments
Pass: Density Pass
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
Digitally signed
Dan J byDan J
Zrallack:
Z ra I I a c k: Date: 2021.09.20
®®eA�1I I I Wffl:®-04'00'
J. zr� ®��B 9
fro.63911
°\ STATE OF
0.
° �Qa
/21
�I°�1�®®v�
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.
Page 1 of 1