HomeMy WebLinkAboutE0-1 Baron CAC LIGHTING FIXTURE SCHEDULE ELECTRICAL SPECIFICATIONS ELECTRICAL SHEET INDEX TYPE DESCRIPTION MANUFACTURER CATALOG NUMBER VOLT LAMP COLOR LUMENS LAMP TYPE DIM TYPE WATTS MOUNTING NOTES FE2 ELECTRICAL NOTES, LEGEND & INDEX PART 1 - GENERAL L1 2X4 ARCH TROFFER METALUX 24RLN-LD5-45-UNV-L835-CD1-U UNV 3500 4500 LED 0-10V 34 RECESSED A. THE CONTRACTOR SHALL SUPPLY AND INSTALL ALL NEW ELECTRICAL WORK INDICATED. LIGHTING PLAN CONSTRUCTION SHALL BE IN ACCORDANCE WITH DRAWINGS AND APPLICABLE SPECIFICATIONS. IF A PROBLEM IS ENCOUNTERED IN COMPLYING WITH THIS REQUIREMENT, CONTRACTOR SHALL NOTIFY POWER PLAN L1E 2X4 ARCH TROFFER W/EM METALUX 24RLN-LD5-45-UNV-EL7W-L835-CD1-U UNV 3500 4500 LED 0-10V 35 RECESSED THE ARCHITECT/ENGINEER AS SOON AS POSSIBLE AFTER DISCOVERY OF THE PROBLEM AND A R C H I T E C T S D E S I G N SHALL NOT PROCEED WITH THAT PORTION OF THE WORK UNTIL ARCHITECT/ENGINEER HAS DIRECTED ELECTRICAL RISER DIAGRAM COLLABORATIVE , LLC CORRECTIVE ACTION TO BE TAKEN. B. THE CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BID AND FAMILIARIZE HIMSELF WITH ALL ARCHITECTURE I URBAN DESIGN L2 2X4 FLAT PANEL METALUX 24FP4735C UNV 3500 4500 LED 0-10V 36 RECESSED CONDITIONS AFFECTING ELECTRICAL AND COMMUNICATIONS INSTALLATION AND MAKE PROVISIONS AS TO PLANNING I INTERIORS THE COST THEREOF. C. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC 10489 SOUTHWEST MEETINGST L2E 2X4 FLAT PANEL W/EM METALUX 24FP4735C-EL7W UNV 3500 4500 LED 0-10V 37 RECESSED CODE (AS ADOPTED BY THE AUTHORITY HAVING JURISDICTION) AND ALL CODES AND ORDINANCES OF THE TRADITION, ELECTRICAL LEGEND PORT ST 4987 AUTHORITY HAVING JURISDICTION. THE SPECIFICATION, CODES AND STANDARDS LISTED BELOW ARE TEL.(772)2J 28286 9009004 UTILIZED IN THIS PROJECT. L3 2X4 ARCH TROFFER (HARD CEILING) METALUX 24RLN-LD5-45-UNV-L835-CD1-U/ DF-24W UNV 3500 4500 LED 0-10V 34 RECESSED 1. NATIONAL ELECTRICAL CODE (NFPA-70) www. ADC-ARCHITECTS.NET 2. CODE FOR SAFETY TO LIFE (NFPA-101) TELEPHONE OUTLET WITH 3/4" CONDUIT STUBBED OUT FROM WALL 6" ABOVE CEILING. REGISTRATIONS HELD IN THE FOLLOWING STATES: 3. STANDARD FOR THE INSTALLATION, MAINTENANCE AND USE OF LOCAL PROTECTIVE SIGNALING MOUNT 18" A.F.F. TO CENTER LINE OF OUTLET UNLESS OTHERWISE NOTED. CALIFORNIA,COLORADO, FLORIDA GEORGIA, NORTH CAROLINA SYSTEMS NFPA-72 MISSISSIPPI,TEXAS L4 4" DOWNLIGHT(WALL WASH) HALO HC415DO10-HM412835-41RWW-W UNV 3500 1500 LED 0-10V 14 RECESSED 4. UNDERWRITERS' LABORATORIES (UL) DATA OUTLET WITH 3/4" CONDUIT STUBBED OUT FROM WALL 6" ABOVE CEILING. 5. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) V MOUNT 18" A.F.F. TO CENTER LINE OF OUTLET UNLESS OTHERWISE NOTED. ARCHITECTURE 6. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) URBAN DESIGN EX EDGE LIT ISOLITE UEL EM-G-1C2M MTEBR UNV N/A N/A LED NIA 1.5W UNIVERSAL 7. FEDERAL 8. INSULATED POWERATION CABLEFENGINEERS ASSOCIATION (IPCEA) � MOUNTEDE/DATA OUTLET ABOVE COUNTER,WSEE ARCHITECTURAL ODUIT TUBBED OUT DRAWNG FOR ROM SPECIFIC L 6" ABOVE REQUIREEMENTSILING. PLANNING INTERIORS 9. FLORIDA BUILDING CODE. FBC 2020 EDITION FIXTURE SCHEDULE NOTES THESE DRAWINGS ARE INSTRUMENTS OF SERVICE. 10. INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS (IEEE) TELEPHONE/DATA OUTLET WITH 3/4" CONDUIT STUBBED OUT FROM WALL 6" ABOVE CEILING. ARCHITECTS DESIGN COLLABORATIVE, LLC HEREBY 11. CITY OF PORT SAINT LUCIE BUILDING CODE. (AMENDMENTS TO FLORIDA BUILDING CODE FBC 2020) 0 MOUNT 18" A.F.F. TO CENTER LINE OF OUTLET UNLESS OTHERWISE NOTED. PPROPERTY RIGHTS°INMTHESE PLANS, SPECIFICATIONS, 12. ADDITIONALLY, DESIGNS, WORK PRACTICES AND CONDITIONS MUST CONFORM WITH THE DESIGNS AND IDEAS. THESE PLANS, SPECIFICATIONS, DESIGNS AND IDEAS ARE FOR QUESTIONS PERTAINING TO THIS FIXTURE SCHEDULE PLEASE CONTACT RYAN HUFF @LIGHTING DYNAMICS-772-285 7169 OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 (OSHA) NMTELEPHONE/DATA OUTLET WITH 3/4" CONDUIT RUN TO THE NEAREST STUD WALL AND NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN D. DO NOT SCALE THE ELECTRICAL DRAWINGS. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS STUBBED OUT FROM WALL 6" ABOVE CEILING. PROVIDE BRASS COVER PLATE AND APPROVAL OF ARCHITECT. FOR EXACT LOCATION OF ALL EQUIPMENT. CONFIRM WITH OWNER'S REPRESENTATIVE. CARPET FLANGE. H DRAW INGS ARE NOT TO BE SCALED (WRITTEN DIMEMENSIONS SHALL GOVERN). ANY DISCREPANCY BETWEEN THESE DRAWINGS AND SPECIFICATIONS AND E. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE BETWEEN THEM AND FIELD CONDITIONS SHALL BE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM TELEVISION RECESSED OUTLET. LEGRAND "TVl WMTVSSWCC2". RESOLVED IN WRITING THIRD THIS OFFICE (772) 286 MOUNT AT 18" A.F.F. TO CENTER LINE OF OUTLET UNLESS OTHERWISE NOTED. 9004. THESE PLANS ARE NOT TO BE SUBMITTED FOR AND PROVIDE ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. PERMIT UNLESS SIGNED & SEALED BY ARCHITECT. F. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FROM A 20 AMP SINGLE RECEPTACLE (NEMA 5-20R) MOUNTED AT 18" A.F.F. TO CENTER LINE OF PERIOD OF NOT LESS THAN ONE YEAR FROM DATE OF ACCEPTANCE. 'I' OUTLET UNLESS NOTED OTHERWISE. G. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED (m 20 AMP DUPLEX RECEPTACLE (NEMA 5-20R) MOUNTED AT 18" A.F.F. TO CENTER LINE OF THERE BY. TTTT OUTLET UNLESS NOTED OTHERWISE. H. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY AND 20 AMP QUADRUPLEX RECEPTACLE (NEMA 5-20R) MOUNTED AT 18" A.F.F. TO CENTER LINE PROPERTY DAMAGE FOR THE DURATION OF THE WORK. lf� OF OUTLET UNLESS NOTED OTHERWISE. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTING. CONTRACTOR GFI 20 AMP DUPLEX RECEPTACLE NEMA 5-20R WITH GROUND FAULT CIRCUIT INTERRUPTER, TO OBTAIN PERMIT AND APPROVED SUBMITTALS PRIOR TO BEGINNING WORK OR ORDERING EQUIPMENT. ( ) THE TERM PROVIDE USED IN THE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS SHALL MEAN THAT MOUNT AT 18" A.F.F. TO CENTER LINE OF OUTLET. UNLESS NOTED OTHERWISE. THE CONTRACTOR IS TO FURNISH, INSTALL AND CONNECT COMPLETE. Ja} 20 AMP DUPLEX RECEPTACLE (NEMA 5-20R) MOUNTED ABOVE COUNTER REVISIONS: PART 2 - PRODUCTS T SEE ARCHITECTURAL DRAWINGS FOR SPECIFIC REQUIREMENTS. A. MINIMUM WIRE SIZE SHALL BE #12 A.W.G. (EXCEPT AS NOTED OTHERWISE FOR CONTROL WIRING). ALL 20 AMP DUPLEX RECEPTACLE (NEMA 5-20R) WITH ISOLATED GROUND, MOUNT AT 18" A.F.F. No. Description Date CONDUCTORS SHALL BE 98% CONDUCTIVITY, COPPER WITH "THHN-THWN" INSULATION UNLESS OTHERWISE TO CENTERLINE OF OUTLET UNLESS OTHERWISE NOTED. NOTED. Z61 20 AMP QUADRUPLEX RECEPTACLE (NEMA 5-20R) WITH ISOLATED GROUND, MOUNT AT 18" B. ELECTRICAL METALLIC TUBING (EMT) SHALL BE OF BEST QUALITY STEEL, SMOOTH INSIDE AND OUT T A.F.F. TO CENTERLINE OF OUTLET UNLESS OTHERWISE NOTED. AND SHALL BE HOT-DIPPED GALVANIZED. 20 AMP DUPLEX RECEPTACLE (NEMA 5-20R), RECESS FLOOR MOUNTED. PROVIDE BRASS C. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS COVER PLATE AND CARPET FLANGE. I. IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. D. RIGID NONMETALIC CONDUIT SHALL BE SCHEDULE 40 PVC. 20 20 AMP DUPLEX RECEPTACLE (NEMA 5-20R), CEILING MOUNTED. L: ALL MATERIALS SHALL BE NEW AND BEAR UNDERWRITERS' LABELS WHERE APPLICABLE. F. PANELBOARDS: SPECIAL-PURPOSE RECEPTACLE 1. CURRENT CARRYING BUSES SHALL BE COPPER. GROUND BUS BARS SHALL BE COPPER. 2. ALL CIRCUIT BREAKERS SHALL BE BOLT ON. PLUG-IN BREAKERS ARE NOT ACCEPTABLE. Q JUNCTION BOX 3. CIRCUIT BREAKERS USED AS SWITCHES IN FLUORESCENT OR HID LIGHTING CIRCUITS SHALL BE LISTED AND MARKED "SWD" OP SINGLE GANG JUNCTION BOX FOR POWER CONNECTION TO MODULAR FURNITURE SYSTEM 4. ALL CIRCUIT BREAKERS FEEDING MECHANICAL EQUIPMENT SHALL BE HACR TYPE. INSTALL IN EXACT MANNER AS DIRECTED BY FURNITURE SUPPLIER. 5. A.I.C. RATINGS SHALL BE AS INDICATED ON PANELBOARD SCHEDULES. DOUBLE GANG JUNCTION BOX FOR TELEPHONE/DATA CONNECTION TO MODULAR FURNITURE 6. ALL PANELBOARDS SHALL BE FURNISHED WITH PLASTIC LAMINATE NAMEPLATES WITH 1/4 OT/D SYSTEM. INSTALL IN EXACT MANNER AND LOCATION AS DIRECTED BY FURNITURE ENGRAVED LETTERING FOR PANEL IDENTIFICATION. SUPPLIER. EXTEND (2) 3/4" EMPTY CONDUITS FROM JUNCTION BOX TO ABOVE 7. ALL PANELBOARDS SHALL BE PROVIDED WITH TYPE-WRITTEN DIRECTORY OF BRANCH CIRCUIT CEILING AND TERMINATE WITH INSULATING BUSHING 6" FROM WALL. DESIGNATIONS. G. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK-MAKE, QUICK-BREAK. ENCLOSURES Q TELE/POWER POLE FOR TELEPHONE/DATA/POWER CONNECTION TO MODULAR FURNITURE SHALL BE NEMA-1 FOR INDOOR LOCATIONS, NEMA 3R FOR OUTDOOR LOCATIONSOR AS OTHERWISE NOTED. 8 WIRE SYSTEM (SEE DETAIL THIS SHEET). INSTALL IN EXACT MANNER AND LOCATION H. MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC AS INDICATED ON THE ELECTRICAL DRAWINGS, WITH AS DIRECTED BY FURNITURE SUPPLIER, WIREMOLD CATALOG # 25DTP-4D W/IVORY FINISH. OVERLOAD RELAYS IN EACH PHASE. WIRING DEVICES (GENERAL PURPOSE RECEPTACLES AND WALL SWITCHES) COLOR SHALL BE COORDINATED SPECIAL PURPOSE RECEPTACLE MOUNTED BELOW RAISE FLOOR. WITH CLIENT. PART 3 - EXECUTION EF EXHAUST FAN. SEE MECHANICAL DRAWINGS FOR SPECIFICATIONS. A. COLOR CODING OF CONDUCTORS SHALL BE AS FOLLOWS: 1. 208/120 VOLTS, 3 PHASE, 4-WIRE SYSTEM: UNGROUNDED CONDUCTORS: 1 BLACK, 1 RED AND 1 $ SINGLE POLE, 20 AMP, SWITCH. MOUNT 46" A.F.F. TO CENTERLINE OF SWITCH UNLESS BLUE. GROUNDED (NEUTRAL) CONDUCTOR; WHITE. GROUNDING CONDUCTORS SHALL BE GREEN. OTHERWISE NOTED. 2. 480/277 VOLT, 3-PHASE, 4-WIRE SYSTEM: UNGROUNDED CONDUCTORS: 1 BROWN, 1 YELLOW, AND 1 PURPLE. GROUNDED (NEUTRAL) CONDUCTORS; GREY. GROUNDING CONDUCTORS SHALL BE GREEN. $3 3-WAY, 20 AMP, SWITCH. MOUNT 46" A.F.F. TO CENTERLINE OF SWITCH UNLESS OTHERWISE NOTED. 3. BRANCH CIRCUIT WIRING (#6 AND SMALLER) SHALL BE COLOR CODED BY CONTINUOUS INSULATION COLOR AND FEEDERS AND SERVICES (#4 AND LARGER) SHALL BE CODED AT ALL JUNCTION OR $D SINGLE POLE, 20 AMP, SWITCH WITH DIMMER. MOUNT 46" A.F.F. TO CENTERLINE OF SWITCH PULL POINTS (EXCEPT LB'S OR LBD'S) USING COLOR MARKERS OR PLASTIC TAPE MANUFACTURED UNLESS OTHERWISE NOTED. FOR THE PURPOSE. B. WIRING METHODS $M MOTOR RATED SWITCH [� 1. ALL CONDUCTORS SHALL BE INSTALLED IN ELECTRICAL METALLIC TUBING (EMT) UNLESS OTHERWISE NOTED, SPECIFIED OR AS SPECIFICALLY PROHIBITED BY THE AUTHORITY HAVING VACANCY SENSOR SWITCH, WATTSTOPPER, MOUNT 46" A.F.F. TO CENTERLINE OF SWITCH JURISDICTION. ALL FITTINGS AND COUPLINGS FOR EMT CONDUIT SHALL BE ALL STEEL UNLESS OTHERWISE NOTED. RAIN TIGHT COMPRESSION TYPE OR ALL STEEL CONCRETE TIGHT SET SCREW TYPE. w 2. SCHEDULE 40 PVC CONDUIT, WITH FITTINGS AND COUPLINGS APPROPRIATE FOR THE USE, SHALL $ TWO POLE, 30 AMP SWITCH. MOUNT ADJACENT EQUIPMENT TO BE CONTROLLED. T 1 w w BE INSTALLED UNDERGROUND OR BELOW SLABS ON GRADE. 3. TYPE MC CABLE WITH ALUMINUM ARMOR AND INTERNAL GROUND IS ACCEPTABLE FOR ® FACTORY MOUNTED DISCONNECT/STARTER (SEE MECHANICAL SCHEDULE) USE AS GENERAL BRANCH CIRCUIT WIRING FOR CIRCUITS 20 AMPERES OR LESS AND CONCEALED IN WALLS OR ABOVE SUSPENDED CEILING AND AS APPROVED BY THE AUTHORITY HAVING M JURISDICTION. � A� FUSIBLE DISCONNECT SWITCH A = POLES, B= FRAME SIZE, C= FUSE RATING ILI C. ELECTRICAL SYSTEM SHALL BE COMPLETE AND EFFECTIVELY GROUNDED AS REQUIRED BY THE LATEST a ui EDITION OF THE N.E.C. AND LOCAL CODES. ItED AB FUSIBLE MOTOR STARTER DISCONNECT SWITCH A = POLES, B= NEMA SIZE, C= FUSE RATING �% D. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTED BY ~ [� I- ENGINEER/ARCHITECT. - GROUNDING ELECTRODE & CONDUCTOR SYSTEM O w ,�/ cn E. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS I-� ~ OF CONSTRUCTION. 2 TRANSFORMER I"I O 0 F. THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF POWER AND TELEPHONE ^ a COMPANIES, AND SHALL BE FULLY COORDINATED WITH THEM PRIOR TO COMMENCEMENT OF WORK. O0 {-� E 0 ELECTRICAL PANELBOARD G. PROVIDE AND INSTALL CONDUIT, CONDUCTORS, PULL WIRES, BOXES, COVER PLATES, AND WIRING 0 0r DEVICES, FOR ALL OUTLETS AS INDICATED. H. MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW TELEPHONE WOOD BACKBOARD Z LU AND SUCH AS APPEAR ON THE UL LIST OF APPROVED ITEMS AND SHALL MEET OR EXCEED THE z REQUIREMENTS OF NEC, NEMA, AND IECE. WP WEATHERPROOF ll CONTRACTOR SHALL SUBMIT AT LEAST FIVE (5) SETS OF SHOP DRAWINGS OR CUT SHEETS OF LIGHTING U I� U FIXTURES, SWITCHES, AND OTHER ELECTRICAL ITEMS FOR APPROVAL BY ENGINEER/ARCHITECT. T/C TIME CLOCK O CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED OF HIS WORK. K. ALL LAY-IN LIGHTING FIXTURES SHALL BE SECURED TO THE SUSPENDED CEILING GRID AT EACH CORNER. RE RELOCATED U L. CONTRACTOR SHALL COORDINATE WITH MECHANICAL DRAWINGS AND PROVIDE ALL NECESSARY CONTROL Q U) g WIRING. E EXISTING TO REMAIN LU p M. ALL ELECTRICAL POWER WIRING FOR THE HVAC SYSTEM INCLUDING WIRING THRU LINE VOLTAGE CONTROL DEVICES SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. A.F.F. ABOVE FINISH FLOOR b CO U Q 00 N. THE CONTRACTOR SHALL CONFIRM WITH THE ELECTRICAL UTILITY COMPANY ANY AND ALL REQUIREMENTS O CEILING MOUNTED DUAL TECHNOLOGY MOTION SENSOR BY WATTSTOPPER. SUCH AS: METERING EQUIPMENT REQUIREMENTS AND METERING EQUIPMENT LOCATION, TRANSFORMER SIZE AND LOCATION OR SERVICE POINT, CONDUIT ENTRY AND LUG SIZE RESTRICTIONS. THE CONTRACTOR DWG IDENTIFICATION SHALL SCHEDULE ALL REQUIRED DOWN TIME FOR THE OWNERS CONFIRMATION. O CEILING MOUNTED LOW VOLTAGE DUAL TECHNOLOGY MOTION SENSOR BY WATTSTOPPER. ANY CONFLICTS AND DESCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE LV 0. PROCEEDING WITH ANY WORK. Oi CEILING MOUNTED DAY LIGHTING SENSOR. SENSOR TO CONTROL THE DIMMING OF ALL FIXTURES PER NEC 210.8(B)(2) ALL 15- AND 20-AMPERE, 125-VOLT RECEPTACLES IN NON DWELLING-TYPE KITCHENS DS WITHIN 15' OF THE WINDOWS WITH IN ROOM. ELECTRICAL NOTES TO BE GFCI PROTECTED. P•BRANCH CIRCUIT CONDUCTORS SHALL BE SIZED FOR A MAXIMUM VOLTAGE DROP OF 3% DESIGN LOAD. FBC 2020 FBC ENERGY CONSERVATION SECTION 405.7.3. DRAWN TR/ST DATE: CHECKED Q. FEEDER CONDUCTORS SHALL BE SIZED FOR A MAXIMUM OF 2% VOLTAGE DROP PER 405.7.3. BY: BY: THIS DESIGN 06/25/2021 DRAWING HAS BEEN ISSUED ON CD - ISSUED FOR PERMIT ONLY 06-29-21 THE DATE SHOWN & NOT FOR PRICING OR CONSTRUCITON FOR THE Digitally signed by Bradly Brown NOTED BID Approver DN: c=US, st=Florida, I=Fort KAMM CONSULTING PROJECT#: 2021-0212 Bradl Pierce, o=Kamm Consulting, PROJECT MANAGER: JOHN MAYR JOB MLIE NU�'iIlBIERo M M 1408 Orange Avenue Ou=P rl n cl pa 1, Exec. Vice Fort Pierce,Florida 34950 1 ffkAPhone 954.448.0792 President cn=Bradt Brown jmayr@kammconsulting.com y onsu ng Certification of Authorization#8189 mail=bbrown@kammconsultin PRINCIPAL 08-09-21g. E0*1 Brown Co m Bradly L Brown Florida License#58232 date Date: 2021.08.09 13:01 :40 -04'00' signed