E5-1
SCHEDULE OF BRANCH CIRCUIT PANEL "B" MAIN: 200 AMP / 3 POLE MLO VOLTAGE: 208/120V, 30, 4 WIRE SPEC: SQUARE D OR APPROVED EQUIVALENT MOUNTING: FLUSH AIC SYMM: 22,000 MDP_ DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE KVA KVA KVA CKT. TRIP COND. GND. WIRE DESCRIPTION LIGHTING 12 12 1 2 20 1 0.8 0.8 2 20 172 12 12 LIGHTING MDP-2 A R C H I T E C T S D E S I G N LIGHTING #12 #12 1 2" 20 3 0.8 0.8 4 20 1 2" 12 12 LIGHTING MDP_ COLLABORATIVE , LLC RECEPTACLES 12 12 1/2" 20 5 0.8 0.8 6 20 1 2 12 12 RECEPTACLES RECEPTACLES #12 #12 1/2" 20 7 0.8 0.8 8 20 1/2" #12 #12 RECEPTACLES ARCHITECTURE URBAN DESIGN RECEPTACLES #12 #12 1/2 20 9 0.8 0.8 10 20 1 2 #12 #12 RECEPTACLES PLANNING I INTERIORS RECEPTACLES #12 #12 1 2 20 11 0.81 0.8 12 20 1/2- 12 #12 RECEPTACLES M D P RECEPTACLES #12 #12 1 2 20 13 0.81 0.8 14 20 1 2 12 12 RECEPTACLES 10489 SOUTHWEST MEETINGST RECEPTACLES 12 12 1 2 20 15 0.8 0.8 16 20 1 2 12 12 RECEPTACLES 600A PANEL PANEL PANEL TRADITION, ILL �� �� �� �� "Coo PORT ST.LUCIE,FL 34987 RECEPTACLES 12 12 1 2 20 17 0.8 0.8 18 20 1 2 12 12 RECEPTACLES A B C TEL.(772)286 9004 RECEPTACLES 12 12 1/2" 20 19 0.8 0.8 20 20 1 2 12 12 RECEPTACLES EXSITING 120/208V 30 e RECEPTACLES #12 #12 1/2" 20 21 0.8 0.8 22 20 1/2" #12 #12 RECEPTACLES FPL TRANSFORMER www. ADC-ARCHITECTS.NET RECEPTACLES 12 12 1 2 20 23 0.8 0.8 24 20 1 2 12 12 RECEPTACLES '`r -- RECEPTACLES 12 12 1 2 20 25 0.8 1.0 26 20 1 2 12 12 DRINKING FOUNTAIN 1` REGISTRATIONS HELD IN THE FOLLOWING STATES: RECEPTACLES 12 12 1 2 20 27 0.8 0.8 28 20 1 2 12 12 EXTERIOR SERVICE RECEPTACLES I / I CALIFORNIA,CORTH CA , FLORIDA GEORGIA, NORTH CAROLINA RTU-2 3#8 1#10 1 40 29 4.3 2.3 30 4 3 4 1#10 2#8 WATER HEATER I / I MISSISSIPPI,TEXAS 31 4.3 2.3 32 2 3 33 4.3 4.3 34 40 1 1#10 3#8 RTU-3 I / I ARCHITECTURE SPARE - - - 20 35 - 4.3 36 URBAN DESIGN SPARE - - - 20 37 - 4.3 38 3 SPARE - - - 20 39 - - 40 20 - - - SPARE PLANNING INTERIORS SPARE - - - 20 41 - 1 42 20 - - - SPARE THESE DRAWINGS ARE INSTRUMENTS OF SERVICE. ARCHITECTS DESIGN COLLABORATIVE, LLC HEREBY 159.2 1 13K-3-1 144.2 AMPS PER PHASE PRESERVES ITS COMMON LAW COPYRIGHT AND OTHER 53.0 TOTAL KVA NEW PROPERTY RIGHTS IN THESE PLANS, SPECIFICATIONS, DESIGNS AND IDEAS. THESE 2 SETS - 4-350MCM - 3" EXISTING ------ PLANS, sCOPPSATIONs, DESIGNS AND IDEAS ARE NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN 1#1 G APPROVAL OF ARCHITECT. THESE DRAWINGS ARE NOT TO BE SCALED (WRITTEN DIMENSIONS SHALL GOVERN). ANY DISCREPANCY BETWEEN THESE DRAWINGS AND SPECIFICATIONS AND SCHEDULE OF BRANCH CIRCUIT PANEL "C" ELECTRICAL RISER NOTES BETWEEN THEM AND FIELD CONDITIONS SHALL BE RE SOLVED IN WRITING THIRD THIS OFFICE (772) 286 9004. THESE PLANS ARE NOT TO BE SUBMITTED FOR PERMIT UNLESS SIGNED & SEALED BY ARCHITECT. MAIN: 200 AMP / 3 POLE MLO VOLTAGE: 208/120V, 30, 4 WIRE SPEC: SQUARE D OR APPROVED EQUIVALENT G O1 1# 1 GROUNDING ELECTRODE CONDUCTOR MOUNTING: FLUSH AIC SYMM: 22,000 6 IN 1" SCHEDULE 40 PVC CONDUIT. DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE CKT.1 TRIP COND. GND. WIRE DESCRIPTION KVA KVA KVA G G O EXOTHERMIC CONNECTION. ELECTRICALLY CONT- LIGHTING #12 #12 1 2 20 1 0.8 0.8 2 20 1 2 12 12 LIGHTING 2 1 INUOUS STEEL REINFORCING BAR IN BOTTOM OF LIGHTING 12 12 1 2 20 3 0.8 0.8 4 20 1 2 12 12 RECEPTACLES 1 5 C/W BUILDING FOUNDATION IN DIRECT CONTACT WITH RECEPTACLES #12 #12 1 2 20 5 0.8 0.8 6 20 1 2 #12 #12 RECEPTACLES 0 RECEPTACLES #12 #12 1 2 20 7 0.81 0.8 8 20 1 2 12 12 RECEPTACLES EARTH. RECEPTACLES 12 12 1 2 20 9 0.8 0.8 10 20 1 2 12 12 RECEPTACLES G - G 10 FT. LONG x 3 4 DIAMETER COPPER DRIVEN RECEPTACLES 12 12 1/2" 20 11 0.8 0.8 12 20 1 2 12 12 RECEPTACLES  / RECEPTACLES 12 12 1/2" 20 13 0.8 0.8 14 20 1 2" 12 12 RECEPTACLES = GROUND ELECTRODE. REVISIONS: RECEPTACLES 12 12 1/2" 20 15 0.8 0.8 16 20 1 2 12 #12 RECEPTACLES 4 No. Description Date RECEPTACLES #12 #12 1/2" 20 17 0.8 0.8 18 20 1/2" #12 #12 RECEPTACLES O EXOTHERMIC CONNECTION. (TYPICAL) P RECEPTACLES 12 12 1/2 20 19 0.8 4.3 20 40 1 1#10 3#8 RTU-5 G RTU-4 3#8 1#10 1 35 21 3.7 4.3 22 3 O MAKE CONNECTION TO METALLIC COLD WATER 23 3.7 4.3 24 3 ENTRANCE PIPE BEFORE FIRST VALVE WITH 3 25 3.7 0.8 26 20 1/2" 12 12 EXTERIOR SERVICE RECEPTACLES HEAVY DUTY BRONZE GROUND CLAMP. SPARE - - - 20 27 - - 28 20 - - - SPARE _ SPARE - - - 20 - - 30 20 - - - SPARE 31 O PROVIDE 1# 3/0 BONDING JUMPER AROUND SPARE - - - 20 31 - - 32 20 - - - SPARE 1 O 7_O n SPARE - - - 20 33 - - 34 20 - - - SPARE L L FIRST VALVE. SPARE - - - 20 35 - - 36 20 - - - SPARE SPARE - - - 20 r39 - - 38 20 - - - SPARE SPARE - - - 20 - - 40 20 - - - SPARE SPARE - - - 20 - - 42 20 - - - SPARE EXISTING ELECTRICAL RISER DIAGRAM 14.4 12.8 12.8 1 KVA PER PHASE 120.0 106.7 106.7 1 AMPS PER PHASE 40.0 1 TOTAL KVA SCHEDULE OF BRANCH CIRCUIT PANEL "A". SCHEDULE OF DISTRIBUTION PANEL "MDP" MAIN: 100 AMP / 3 POLE MLO VOLTAGE: 208/120V, 30, 4 WIRE SPEC: SQUARE D OR APPROVED EQUIVALENT MAIN: 600 AMP / 3 POLE, MAIN CIRCUIT BREAKER VOLTAGE: 208/12OV, 30, 4 WIRE MOUNTING: FLUSH AIC SYMM: 22,000 SPEC: SQUARE D OR APPROVED EQUIVALENT AIC SYMM: 65,000 DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE CKT. TRIP COND. GND. I WIRE DESCRIPTION CIRCUIT BREAKER A PHASE B PHASE C PHASE KVA KVA KVA DESIGNATION DESCRIPTION FEEDER NOTES LIGHTING #12 #12 1 2 20 1 0.8 0.8 2 20 1 2 12 12 LIGHTING FRAME TRIP POLES KVA KVA KVA RECEPTACLES 12 12 1 2 20 3 0.8 0.8 4 20 1 2 12 12 RECEPTACLES MDP-1 PANEL A - 100 3 - - 9.8 8.3 8.2 RECEPTACLES 12 12 1 2 20 5 0.8 0.8 6 20 1 2 12 12 RECEPTACLES MDP-2 PANEL B - 200 3 4 3 0 & 1 2G - 2-1 2 19.1 1 . 1 .3 RECEPTACLES 12 12 1 2 20 7 0.8 0.8 8 20 1 2 12 12 RECEPTACLES MDP-3 PANEL C - 200 3 4 3 0 & 1 2G - 2-1 2 14.4 122.88 122.8 RECEPTACLES 12 12 1 2" 20 9 0.8 0.8 10 20 1/2" 12 12 RECEPTACLES MDP-4 SPARE - - 3 - - - RTU-1 3#8 1#10 1 40 11 4.3 2.3 12 4 3 4 1#10 2#8 INSTAHOT _ 13 4.3 2.3 14 2 _ 3 15 4.3 0.8 16 20 1/2" 12 12 EXTERIOR SERVICE RECEPTACLE _ SPARE - - - 20 17 - - 18 20 - - - SPARE _ SPARE - - - 20 19 - - 20 20 - - - SPARE _ SPARE - - - 20 21 - - 22 20 - - - SPARE 43.3 37.7 38.3 KVA PER PHASE SPARE - - - 20 23 - - 24 20 - - - SPARE 360.8 314.2 319.2 AMPS PER PHASE SPARE - - - 20 25 - - 26 20 - - - SPARE 119.3 TOTAL KVA SPARE - - - 20 27 - - 28 20 - - - SPARE rTl SPARE - - - 20 29 - - 30 20 - - - SPARE �J•� SPARE - - - 20 31 - - 32 20 - - - SPARE SPARE - - - 20 33 - - 34 20 - - - SPARE �j l SPARE - - - 20 35 - - 36 20 - - - SPARE SPARE - - - 20 37 - - 38 20 - - - SPARE _ w SPARE - - - 20 39 - - 40 20 - - - SPARE w SPARE - - - 1 20 41 - - 421 20 - - - SPARE w 9.8 8.3 8.2 KVA PER PHASE W 81.7 1 69.2 68.3 AMPS PER PHASE 00 26.3 ITOTAL KVA m OM ^^ ILL J w O a O E U) O Z � w w z 0 LU U U OIt--I v o of LU p H � U Z p CO O p L0 U Q 00 DWG IDENTIFICATION RISER DIAGRAM DRAWN TR/ST DATE: CHECKED BY: BY: THIS DESIGN 06/25/2021 DRAWING HAS BEEN ISSUED ON CD Digitally signed by Bradly ISSUED FOR PERMIT ONLY 06-29-21 THE DATE SHOWN & NOT FOR PRICING OR CONSTRUCITON FOR THE Brown NOTEDPURPOSE BID Approver NOTED Bradl DN: c=US, st=Florida, I=Fort KAMMCONSULTING PROJECT#: 2021-0212 Pierce, o=Kamm Consulting, PROJECT MANAGER: JOHNMAYR �1JOBF�LENU�1C ERA 1408 Orange Avenue Ou=Principal, Exec. Vice M M Fort Pierce,Florida 34950 Phone 954.448.0792 President, cn=Bradly Brown, jmayr@kammconsulting.com email=bbrown@kammconsult °"s° "9 certification of Authorization#8189 PRINCIPAL 08-09-21 E591 i ng.co m Bradly L Brown Florida License#58232 date Brown Date: 2021 .08.09 13:00:43 signed -04'00'