HomeMy WebLinkAboutENERGY EFFICIENCY CODE Florida Building Code, Seventh Edition (2020) - Energy Conservation EnergyGauge Summit® Fla/Com-2020, Effective Date: Dec 31, 2020 C402.1.2: ASHRAE Prescriptive Compliance Option Check List Applications for compliance with the Florida Building Code, Energy Conservation shall include: [� This Checklist [� The full compliance report generated by the software that contains the project summary, compliance summary, certifications and detailed component compliance reports. The compliance report must include the full input report generated by the software as contigous part of the compliance report. [(� Boxes appropriately checked in the Mandatory Section of the complaince report. WARNING: INPUT REPORT NOT GENERATED. To include input report in final submission, go to the Project Form, Settings Tab and check the box - "Append Input Report to Compliance Output Report" Then rerun your calculation EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 1 of 19 PROJECT SUMMARY Short Desc: CHILD ADVOCACY Description: 2021-0212 Owner: - Addressl: 8565 COMMERCE CENTER DRIVE City: PORT ST.LUCIE Address2: - State: FLORIDA Zip: 34968 Type: Office Class: Renovation to existing buildi Jurisdiction: PORT ST LUCIE, ST LUCIE COUNTY,FL(661200) Conditioned Area: 8490 SF Conditioned&UnConditioned Area: 8490 SF No of Stories: 1 Area entered from Plans 0 SF Permit No: 0 Max Tonnage 4.8 If different,write in: EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 2 of 19 Compliance Summary Component Design Criteria Result ENVELOPE PRESCRIPTIVE PASSES LIGHTING POWER 3,988.0 6,876.9 PASSES LIGHTING CONTROLS PASSES EXTERNAL LIGHTING No Entry HVAC SYSTEM PASSES PLANT No Entry WATER HEATING SYSTEMS Not Checked PIPING SYSTEMS No Entry Met all required compliance from Check List? Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 3 of 19 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Bradly Prepared By: Brown Building Official: Date: Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (*)that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: BRAD BROWN Reg No: 58232 Lighting Designer: BRAD BROWN Reg No: 58232 Mechanical Designer: BRAD BROWN Reg No: 58232 Plumbing Designer: BRAD BROWN Reg No: 58232 (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. Project: CHILD ADVOCACY Title: 2021-0212 Type: Office (WEA File: FL_ST_LUCIE_CO_INTL.tm3) Prescriptive Envelope Compliance Item Zone Description Design Criteria Meet Req. ZONE 1 ZONE 1 Slab Floor F-Value Max allowed .600 0.730 Yes ZONE 2 ZONE 2 Slab Floor F-Value Max allowed .600 0.730 Yes ZONE 3 ZONE 3 Slab Floor F-Value Max allowed .600 0.730 Yes ZONE 4 ZONE 4 Slab Floor F-Value Max allowed .600 0.730 Yes ZONE 5 ZONE 5 Slab Floor F-Value Max allowed .600 0.730 Yes Meets Prescriptive Envelope Requirements -- PASSES EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/l/2021 Page 4 of 19 External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No.of Units (W) (W) (Sgft or ft) None Project: CHILD ADVOCACY Title: 2021-0212 Type: Office (WEA File: FL_ST_LUCIE_CO_INTL.tm3) Lighting Power Compliance Space Ashrae Description Area Height No.of Design Effective Allowance ID (sq.ft) (ft) Spaces (W) (W) (W) ZONE 1 16 Office-Open Plan 2,302 9.0 1 756 756 1,865 ZONE 2 16 Office-Open Plan 1,436 9.0 1 750 750 1,163 ZONE 3 16 Office-Open Plan 1,885 9.0 1 1122 1122 1,527 ZONE 4 16 Office-Open Plan 1,657 9.0 1 850 850 1,342 ZONE 5 16 Office-Open Plan 1,210 9.0 1 510 510 980 Design 3988 (W) PASSES Effective: 3988 (W) Allowance: 6876.9 (W) Passing requires Design to be at most 100% of Criteria Project: CHILD ADVOCACY Title: 2021-0212 Type: Office (WEA File: FL ST LUCIE CO INTL.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compliance ID (sq.ft) CP CP ZONE 1 16 Office-Open Plan 2,302 9 1 PASSES ZONE 2 16 Office-Open Plan 1,436 9 1 PASSES ZONE 3 16 Office-Open Plan 1,885 1 1 PASSES ZONE 4 16 Office-Open Plan 1,657 9 1 PASSES ZONE 5 16 Office-Open Plan 1,210 7 1 PASSES PASSES EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 5 of 19 Project: CHILD ADVOCACY Title: 2021-0212 Type: Office (WEA File: FL_ST_LUCIE_CO_INTL.tm3) System Report Compliance RTU 1 ZONE 1 Constant Volume Packaged No.of Units System--902 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air 57900 14.00 14.00 8.00 PASSES Cooled 0 to 65000 Btu/h Cooling Capacity Heating System Electric Furnace 25590 1.00 1.00 PASSES Air Handling Air Handler(Supply)- 2000 0.80 0.82 PASSES System-Supply Constant Volume RTU 2 ZONE 2 Constant Volume Air Cooled No.of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air 46000 14.00 13.00 8.00 PASSES Cooled Split System< 65000 Btu/h Cooling Capacity Heating System Electric Furnace 25590 1.00 1.00 PASSES Air Handling Air Handler(Supply)- 1600 0.80 0.82 PASSES System-Supply Constant Volume RTU 3 System 3 Constant Volume Air Cooled No. of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air 40000 14.00 13.00 8.00 PASSES Cooled Split System< 65000 Btu/h Cooling Capacity Heating System Electric Furnace 25590 1.00 1.00 PASSES Air Handling Air Handler(Supply)- 1400 0.80 0.82 PASSES System-Supply Constant Volume EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 6 of 19 RTU 4 ZONE 4 Constant Volume Air Cooled No. of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air 46000 14.00 13.00 8.00 PASSES Cooled Split System< 65000 Btu/h Cooling Capacity Heating System Electric Furnace 25590 1.00 1.00 PASSES Air Handling Air Handler(Supply)- 1600 0.80 0.82 PASSES System-Supply Constant Volume RTU 5 ZONE 5 Constant Volume Packaged No. of Units System--902 I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air 57900 14.00 14.00 8.00 PASSES Cooled 0 to 65000 Btu/h Cooling Capacity Heating System Electric Furnace 25590 1.00 1.00 PASSES Air Handling Air Handler(Supply)- 2000 0.80 0.82 PASSES System-Supply Constant Volume PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/l/2021 Page 7 of 19 Project: CHILD ADVOCACY Title: 2021-0212 Type: Office (WEA File: FL_ST_LUCIE_CO_INTL.tm3) Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance Water Heater 1 Electric Storage water Unknown 0.96 Not Checked heater Not Checked Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compl- [inches] Runout? Temp [Btu-in/hr Thick[in] Thick[in] iance [F] SF.F] None EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 8 of 19 Mandatory Requirements (as applicable) Requirements compiled by US Department of Energy and Pacific Northwest National Laboratory. Adopted for FBC with permission. Not all may be applicable Topic Section Component Description Yes N/A Exempt 1. To be checked by Designer or Engineer Insulation 5.8.1.2 Envelope Below-grade wall insulation installed per El manufacturer's instructions. Insulation 5.8.1.2 Envelope Slab edge insulation installed per manufacturer's [� instructions. Insulation 5.5.3.5 Envelope Slab edge insulation depth/length. DEX El Insulation 6.4.4.1.5 Envelope Bottom surface of floor structures incorporating radiant heating insulated to> R-3.5. SYSTEM—SPECIFIC 6.5.1,6.5.1.1, Mechanical Air economizers provided where required(and not El EX 6.5.1.3,6.5.1.4 exempted),meet the requirements for design capacity,control signal,ventilation controls, high-limit shut-off,integrated economizer control, and provide a means to relieve excess outside air during operation. SYSTEM—SPECIFIC 6.5.1,6.5.1.2, Mechanical Water economizers provided where required, El 6.5.1.2.1,6.5.1.3 meet the requirements for design capacity, maximum pressure drop and integrated economizer control.Capable if providing 100%of the expected system cooling load when outdoor air—50F. SYSTEM—SPECIFIC 6.5.1.5 Mechanical Economizer operation will not increase heating El energy use during normal operation. SYSTEM—SPECIFIC 6.5.2.2.1 Mechanical Three-pipe hydronic systems using a common El El return for hot and chilled water are not used. SYSTEM—SPECIFIC 6.5.2.2.3 Mechanical Hydronic heat pump systems connected to a El EX common water loop meet heat rejection and heat addition requirements. SYSTEM—SPECIFIC 6.5.1.6 Mechanical Water economizer specified on hydronic cooling ❑ EX ❑ and humidification systems designed to maintain inside humidity at>35 OF dewpoint if an economizer is required. SYSTEM—SPECIFIC 6.5.3.1.1 Mechanical HVAC fan systems at design conditions do not D El exceed allowable fan system motor nameplate hp or fan system bhp. SYSTEM—SPECIFIC 6.5.3.1.2 Mechanical HVAC fan motors not larger than the first available D El motor size greater than the bhp. HVAC 6.5.6.1 Mechanical Exhaust air energy recovery on systems meeting El EX Tables 6.5.6.1-1,and 6.5.6.1-2. SYSTEM—SPECIFIC 7.4.2 Mechanical Service water heating equipment meets efficiency ❑ L� El requirements. gyp' SYSTEM—SPECIFIC 7.5.2 Mechanical Service water heating equipment used for space El El heating complies with the service water heating equipment requirements. Insulation 5.8.1.2 Envelope Above-grade wall insulation installed per manufacturer's instructions. Insulation 5.8.1.2 Envelope Floor insulation installed per manufacturer's instructions. Controls 10.4.3 Mechanical Elevators are designed with the proper lighting, 11V El ventilation power,and standby mode. SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7a Mechanical Heat Rejection Equipment:Minimum Efficiency Requirement> 40.2 gpm/hp. SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7b Mechanical Heat Rejection Equipment:Minimum Efficiency El Requirement> 20.0 gpm/hp. SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7c Mechanical Heat Rejection Equipment: Minimum Efficiency Requirement> 16.1 gpm/hp. EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 9 of 19 SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7d Mechanical Heat Rejection Equipment:Minimum Efficiency ❑ ❑ Requirement—7.0 gpm/hp SYSTEM—SPECIFIC 6.5.5.3 Mechanical Centrifugal fan open-circuit cooling towers having ❑ [x Elcombined rated capacity>= 1100 gpm meets minimum efficiency requirement:>=38.2 gpm/hp. SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7e Mechanical Heat Rejection Equipment:Minimum Efficiency Requirement>=176 kBtu/h-hp SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7f Mechanical Heat Rejection Equipment:Minimum Efficiency El E2' El Requirement> 157 kBtu/h-hp w/R-507A test fluid. SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7g Mechanical Heat Rejection Equipment:Minimum Efficiency ❑ P, ❑ Requirement> 134 kBtu/h-hp w/Ammonia test fluid.. SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7h Mechanical Heat Rejection Equipment: Minimum Efficiency ❑ V ❑ Requirement> 135 kBtu/h-hp w/R-507A test fluid. SYSTEM—SPECIFIC 6.4.1.1,6.8.1-7i Mechanical Heat Rejection Equipment: Minimum Efficiency El U' El Requirement>=110 kBtu/h-hp w/Ammonia test fluid. El R( El 7.5.3 Mechanical Gas-fired water-heating equipment installed in new buildings:where a singular piece of water-heating equipment =1,000 kBtu/h serves the entire building,thermal efficiency must be>_ 90 Et. Where multiple pieces of water-heating equipment serve the building with combined rating is>_ 1,000 kBtu/h,the combined input-capacity-weighted-average thermal efficiency,thermal efficiency must be>=90 Et. Exclude input rating of equipment in individual dwelling units and equipment—100 kBtu/h. SYSTEM—SPECIFIC 6.5.3.2.4 Mechanical Return and relief fans used to meet Section El 9' El 6.5.1.1.5 have relief air rate controlled to maintain building pressure through differential supply-return airflow tracking.Systems with supply fans allowed to control the relief system based on oudoor air damper position. Fans have variable speed control or other devices for managing total return/relief fan system demand per section threshold. El El 6.5.2.E Mechanical Units that provide ventilation air to multiple zones and operate in conjunction with zone heating and cooling systems are prevented from using heating or heat recovery to warm supply air above 60°F when representative building loads or outdoor air temperature indicate that most zones demand cooling. ❑ ❑ HVAC 6.5.4.7 Mechanical Chilled-water cooling coils provide a 15°F or higher temperature difference between leaving and entering water temperatures and a minimum of 57°F leaving water temperature at design conditions SYSTEM—SPECIFIC 6.5.3.4 Mechanical Parallel-flow fan-powered VAV air terminals have El ❑ automatic controls to a)turn off the terminal fan except when space heating is required or if required for ventilation;b)turn on the terminal fan as the first stage of heating before the heating coil is activated;and c)during heating for warmup or setback temperature control,either operate the terminal fan and heating coil without primary air or reverse the terminal damper logic and provide heating from the central air handler through primary air. EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 10 of 19 SYSTEM—SPECIFIC 6.5.3.7 Mechanical Required minimum outdoor air rate is the larger of ❑ 19 ❑ minimum outdoor air rate or minimum exhaust air rate required by Standard 62.1,Standard 170,or applicable codes or accreditation standards. Outdoor air ventilation systems shall comply with one of the following:a)design minimum system outdoor air provided<135%of the required minimum outdoor air rate,b)dampers,ductwork, and controls allow the system to supply—the required minimum outdoor air rate with a single set-point adjustment.,or c)system includes exhaust air energy recovery complying with Section 6.5.6.1. HVAC 6.8.1-15,6.8.1-16 Mechanical Electrically operated DX-DOAS units meet requirements per Tables 6.8.1-15 or 6.8.1-16. . To be checked by Plan Reviewe Plan Review 4.2.2,5.4.3.1.1,5.7 Envelope Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Plan Review 4.2.2,6.4.4.2.1, Mechanical Plans,specifications,and/or calculations provide 6.7.2 all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Plan Review 4.2.2,7.7.1, 10.4.2 Mechanical Plans,specifications,and/or calculations provide ❑ ❑ all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. Plan Review 4.2.2,8.4.1.1, Project Plans,specifications,and/or calculations provide ❑ ❑ 8.4.1.2,8.7 all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Plan Review 4.2.2,9.4.3,9.7 Interior Lighting Plans,specifications,and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. Plan Review 9.7 Exterior Lighting Plans,specifications,and/or calculations provide ❑ ❑ all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. Insulation 5.8.1.7.3 Envelope Insulation in contact with the ground has—0.3% water absorption rate per ASTM C272. Air Leakage 5.4.3.4 Envelope Vestibules are installed where building entrances separate conditioned space from the exterior,and meet exterior envelope requirements. Doors have self-closing devices,and are> 7 ft apart(> 16 ft apart for adjoinging floor area—40000 sq.ft.). Vestibule floor area< 7 50 sq.ft.or 2 percent of the adjoining conditioned floor area. EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 11 of 19 Plan Review 5.5.4.2.3 Envelope In buildings>2,500 ft2,any enclosed spaces El El directly under a roof with ceiling heights>15 ft. and used as an office,lobby,atrium,concourse, corridor,storage(including nonrefrigerated warehouse),gymnasium,fitness/exercise area, playing area,gymnasium seating area,convention exhibit/event space,courtroom,automotive service,fire station engine room,manufacturing corridor/transition and bay areas,retail,library reading and stack areas,distribution/sorting area, transportation baggage and seating areas,or workshop,the following requirements apply:The daylight zone under skylights is—half the floor area and(a)the skylight area to daylight zone is —3 percent with a skylight VT—0.40 or(b)the minimum skylight effective aperture—1 percent. The skylights have a measured haze value>90 percent. Plan Review 5.5.4.2.3 Envelope In buildings>2,500 ft2,any enclosed spaces directly under a roof with ceiling heights>15 ft. and used as an office,lobby,atrium,concourse, corridor,storage(including nonrefrigerated warehouse),gymnasium,fitness/exercise area, playing area,gymnasium seating area,convention exhibit/event space,courtroom,automotive service,fire station engine room,manufacturing corridor/transition and bay areas,retail,library reading and stack areas,distribution/sorting area, transportation baggage and seating areas,or workshop,the following requirements apply:The daylight zone under skylights is—half the floor area and(a)the skylight area to daylight zone is —3 percent with a skylight VT—0.40 or(b)the minimum skylight effective aperture—1 percent. The skylights have a measured haze value>90 percent. Plan Review 5.5.4.2.3 Envelope In buildings>2,500 ft2,any enclosed spaces directly under a roof with ceiling heights>15 ft. and used as an office,lobby,atrium,concourse, corridor,storage(including nonrefrigerated warehouse),gymnasium,fitness/exercise area, playing area,gymnasium seating area,convention exhibit/event space,courtroom,automotive service,fire station engine room,manufacturing corridor/transition and bay areas,retail,library reading and stack areas,distribution/sorting area, transportation baggage and seating areas,or workshop,the following requirements apply:The daylight zone under skylights is—half the floor area and(a)the skylight area to daylight zone is —3 percent with a skylight VT—0.40 or(b)the minimum skylight effective aperture—1 percent. The skylights have a measured haze value>90 percent. Plan Review 5.5.4.2.3 Envelope In buildings>2,500 ft2,any enclosed spaces directly under a roof with ceiling heights>15 ft. and used as an office,lobby,atrium,concourse, corridor,storage(including nonrefrigerated warehouse),gymnasium,fitness/exercise area, playing area,gymnasium seating area,convention exhibit/event space,courtroom,automotive service,fire station engine room,manufacturing corridor/transition and bay areas,retail,library reading and stack areas,distribution/sorting area, transportation baggage and seating areas,or workshop,the following requirements apply:The daylight zone under skylights is—half the floor area and(a)the skylight area to daylight zone is —3 percent with a skylight VT—0.40 or(b)the minimum skylight effective aperture—1 percent. The skylights have a measured haze value>90 percent. EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 12 of 19 Plan Review 5.5.4.2.3 Envelope In buildings>2,500 ft2,any enclosed spaces El El directly under a roof with ceiling heights>15 ft. and used as an office,lobby,atrium,concourse, corridor,storage(including nonrefrigerated warehouse),gymnasium,fitness/exercise area, playing area,gymnasium seating area,convention exhibit/event space,courtroom,automotive service,fire station engine room,manufacturing corridor/transition and bay areas,retail,library reading and stack areas,distribution/sorting area, transportation baggage and seating areas,or workshop,the following requirements apply:The daylight zone under skylights is—half the floor area and(a)the skylight area to daylight zone is —3 percent with a skylight VT—0.40 or(b)the minimum skylight effective aperture—1 percent. The skylights have a measured haze value>90 percent. Plan Review 5.5.4.2.3 Envelope In buildings>2,500 ft2,any enclosed spaces directly under a roof with ceiling heights>15 ft. and used as an office,lobby,atrium,concourse, corridor,storage(including nonrefrigerated warehouse),gymnasium,fitness/exercise area, playing area,gymnasium seating area,convention exhibit/event space,courtroom,automotive service,fire station engine room,manufacturing corridor/transition and bay areas,retail,library reading and stack areas,distribution/sorting area, transportation baggage and seating areas,or workshop,the following requirements apply:The daylight zone under skylights is—half the floor area and(a)the skylight area to daylight zone is —3 percent with a skylight VT—0.40 or(b)the minimum skylight effective aperture—1 percent. The skylights have a measured haze value>90 percent. HVAC 6.4.3.4.4 Mechanical Ventilation fans>0.75 hp have automatic controls ❑ ❑ to shut off fan when not required. HVAC 6.4.3.8 Mechanical Demand control ventilation provided for spaces >500 ft2 and>25 people/1000 ft2 occupant density and served by systems with air side economizer,auto modulating outside air damper control,or design airflow>3,000 cfm. HVAC 6.4.4.1.4 Mechanical Thermally ineffective panel surfaces of sensible heating panels have insulation—R-3.5. HVAC 6.5.2.3 Mechanical Dehumidification controls provided to prevent reheating,recooling,mixing of hot and cold airstreams or concurrent heating and cooling of the same airstream. SYSTEM—SPECIFIC 6.5.3.1.3 Mechanical Fans have efficiency grade(FEG)—67.The total efficiency of the fan at the design point of operation—15%of maximum total efficiency of the fan. SYSTEM—SPECIFIC 6.5.3.6 Mechanical Motors for fans—1/12 hp and< 1 hp are electronically-commutated motors or have a minimum motor efficiency of 70%.These motors are also speed adjustable for either balancing or remote control. SYSTEM—SPECIFIC 6.4.3.10 Mechanical DDC system installed and capable of and configured to provide control logic including monitoring zone and system demand for fan pressure,pump pressure,heating,and cooling; transferring zone and system demand information from zones to air distribution system controllers and from air distribution systems to heating and cooling plant controllers;automatically detecting and alerting system operator when zones and systems excessively drive the reset logic;allow operator removal of zone(s)from the reset algorithm;AND capable of trending and graphically displaying input and output points. EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 13 of 19 SYSTEM-SPECIFIC 6.5.3.2.3 Mechanical Reset static pressure setpoint for DDC controlled El El VAV boxes reporting to central controller based on the zones requiring the most pressure.Controls provide:zone damper monitoring or indicator of static pressure need;autodetection,alarm,and operator override of zones excessively triggering reset logic. SYSTEM-SPECIFIC 6.5.3.3 Mechanical Multiple zone VAV systems with DDC of individual ❑ zone boxes have static pressure setpoint reset controls. SYSTEM-SPECIFIC 6.5.3.5 Mechanical Multiple zone HVAC systems have supply air temperature reset controls. SYSTEM-SPECIFIC 6.5.4.1 Mechanical System turndown requirement met through multiple single-input boilers,one or more modulating boilers,or a combination of single-input and modulating boilers. Boiler input between 1.0 MBtu/h and 5 MBtu/h has 3:1 turndown ratio, boiler input between 5.0 MBtu/h and 10 MBtu/h has 4:1 turndown ratio, boiler input>10.0 MBtu/h has 5:1 turndown ratio. HVAC 6.5.4.2 Mechanical HVAC pumping systems with—3 control values designed for variable fluid flow(see section details). SYSTEM-SPECIFIC 6.5.4.3,6.5.4.3.1, Mechanical Fluid flow shutdown in pumping systems to 6.5.4.3.2 multiple chillers or boilers when systems are shut down. SYSTEM-SPECIFIC 6.5.4.4 Mechanical Temperature reset by representative building loads in pumping systems>10 hp for chiller and boiler systems>300,000 Btu/h. SYSTEM-SPECIFIC 6.5.4.5.1 Mechanical Two-position automatic valve interlocked to shut off water flow when hydronic heat pump with pumping system>10 hp is off. SYSTEM-SPECIFIC 6.5.4.5.2 Mechanical Hydronic heat pumps and water-cooled unitary air conditioners with pump systems>5 hp have controls or devices to reduce pump motor demand. SYSTEM-SPECIFIC 6.5.5.2.1 Mechanical Fan systems with motors or array of motors El El (inlcuding the motor service factor)with connected power totaling> 5 hp associated with heat rejection equipment to have controls and/or devises that result in fanmotor demand of—30% of design wattage at 50%of design airflow and automatically modulates fan speed to control the leaving fluid temperature or condensing temp/pressure of heat rejection device. SYSTEM-SPECIFIC 6.5.5.2.2 Mechanical Multicell heat rejection equipment with ❑ El variable-speed fan drives installed that operate the maximum number of fans allowed that comply with manufacturers specs and control all fans to the same fan speed required for the instantaneous cooling duty. SYSTEM-SPECIFIC 6.5.7.1 Mechanical Conditioned supply air to space with mechanical El El exhaust<-the greater of criteria of supply flow, required ventilation rate,exhaust flow minu the available transffer air(see section details). HVAC 6.5.7.2.1 Mechanical Kitchen hoods>5,000 cfm have make up air El El El > 50%of exhaust air volume. SYSTEM-SPECIFIC 6.5.7.2.2 Mechanical Kitchen hoods with a total exhaust airflow rate El El >5000 cfm meet replacement air,ventilation system,or energy recovery requirements shown in Table 6.5.7.1.3. SYSTEM-SPECIFIC 6.5.7.2.3 Mechanical Kitchen hoods with a total exhaust airflow rate El El El >5000 cfm meet replacement air,ventilation system,or energy recovery requirements. HVAC 6.5.7.2 Mechanical Fume hoods exhaust systems—5,000 cfm have El El El VAV hood exhaust and supply systems,direct make-up air or heat recovery. HVAC 6.5.8.1 Mechanical Unenclosed spaces that are heated use only 1:1 El El radiant heat. EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 14 of 19 SYSTEM—SPECIFIC 7.5.1 Mechanical Combined space and water heating system not El El allowed unless standby loss less than calculated maximum.AHJ has approved or combined connected load<150 kBtu/h. Other Equipment 10.4.1 Mechanical Electric motors meet requirements where El El El applicable. HVAC 6.4.3.3.2 Mechanical Setback controls allow automatic restart and El El temporary operation as required for maintenance. SYSTEM—SPECIFIC 6.4.3.3.3 Mechanical Systems with setback controls and DDC include optimum start controls.Optimum start algorithm considers mass radiant slab floor temperature. SYSTEM—SPECIFIC 6.4.3.3.4 Mechanical Zone isolation devices and controls. Wattage 9.4.2 Exterior Lighting Exterior lighting power is consistent with what is El El El shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Controls 9.4.1.4d Exterior Lighting Outdoor parking area luminaires—78W and<_ 24 ft height controlled to reduce wattage by 50% when area unoccupied over 15 minutes. Controlled power limited to— 1500W. Controls 9.4.1.2a Interior Lighting Parking garage lighting is equipped with automatic El El shutoff controls per Section 9.4.1.1(i). Controls 9.4.1.2b Interior Lighting Parking garage luminarie power is automatically reduced by—30%when zone<3600 ft2 has no occupancy after 20 minutes. Controls 9.4.1.2c Interior Lighting Parking garage luminaries in or around covered entrances/exits between building and garage automatically reduced by>=50%from sunset to sunrise. Controls 9.4.1.2d Interior Lighting Parking garage: Power to luminaires—20 ft of any perimeter wall that has a net opening-to-wall ratio> 40%and no exterior obstructions within 20 ft, is automatically reduced in response to daylight>=50%. Other Equipment 6.8.1-14 Mechanical Vapor compression based indoor pool dehumidifiers(single package(indoor air/water cooled or w/out air-cooled condenser)or split system indoor air-cooled)have a minimum 3.5 MIRE efficiency rating. Controls 6.4.3.3.5 Mechanical Hotels/motel w/>50 guest rooms have automatic controls for the HVAC equipment serving each room configured per Section 6.4.3.3.5 subsections 1-3. 3. To be checked by Inspector Insulation 5.8.1.7 Envelope Exterior insulation protected against damage, El El sunlight, moisture,wind,landscaping and equipment maintenance activities. HVAC 6.4.3.7 Mechanical Freeze protection and snow/ice melting system El El sensors for future connection to controls. Air Leakage 5.4.3.1 Envelope Continuous air barrier is wrapped,sealed, caulked,gasketed,and/or taped in an approved manner,except in semiheated spaces in climate zones1-6. Air Leakage 5.4.3.2 Envelope Factory-built and site-assembled fenestration and El El doors are labeled or certified as meeting air leakage requirements. Fenestration 5.8.2.1,5.8.2.3, Envelope Fenestration products rated(U-factor,SHGC,and El El 5.8.2.4,5.8.2.5 VT)in accordance with NFRC or energy code defaults are used. Fenestration 5.8.2.2 Envelope Fenestration and door products are labeled,or a El El signed and dated certificate listing the U-factor, SHGC,VT,and air leakage rate has been provided by the manufacturer. SYSTEM—SPECIFIC 7.4.4.1 Mechanical Temperature controls installed on service water El El El heating systems(<=120°F to maximum temperature for intended use). EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 15 of 19 SYSTEM—SPECIFIC 7.4.4.2 Mechanical Automatic time switches installed to automatically El El D switch off the recirculating hot-water system or heat trace. SYSTEM—SPECIFIC 7.4.6 Mechanical Heat traps installed on non-circulating storage El El D water tanks. HVAC 6.4.1.4,6.4.1.5 Mechanical HVAC equipment efficiency verified. Non-NAECA HVAC equipment labeled as meeting 90.1. SYSTEM—SPECIFIC 6.4.1.5.2 Mechanical PTAC and PTHP with sleeves 16 in. by 42 in. El El El labeled for replacement only. HVAC 6.4.3.4.1 Mechanical Stair and elevator shaft vents have motorized El El dampers that automatically close. HVAC 6.4.3.4.2,6.4.3.4.3 Mechanical Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates.Check gravity dampers where allowed. HVAC 6.4.3.4.5 Mechanical Enclosed parking garage ventilation has automatic El El contaminant detection and capacity to stage or modulate fans to 50%or less of design capacity. HVAC 6.5.3.2.1 Mechanical DX cooling systems—75 kBtu/h(> 65 kBtu/h El El effective 1/2016)and chilled-water and evaporative cooling fan motor hp—%designed to vary supply fan airflow as a function of load and comply with operational requirements. HVAC 6.4.4.1.1 Mechanical Insulation exposed to weather protected from damage. Insulation outside of the conditioned space and associated with cooling systems is vapor retardant. HVAC 6.4.4.1.2 Mechanical HVAC ducts and plenums insulated per Table El El 6.8.2. Where ducts or plenums are installed in or under a slab,verification may need to occur during Foundation Inspection. HVAC 6.4.4.1.3 Mechanical HVAC piping insulation thickness. Where piping is El El El installed in or under a slab,verification may need to occur during Foundation Inspection. HVAC 6.4.4.2.1 Mechanical Ducts and plenums having pressure class ratings ❑ ❑ ❑ are Seal Class A construction. SYSTEM—SPECIFIC 6.4.4.2.2 Mechanical Ductwork operating>3 in.water column requires air leakage testing. SYSTEM—SPECIFIC 6.5.2.1 Mechanical Zone controls can limit reheating,recooling, simultaneous heating and cooling and sequence heating and cooling to each zone. SYSTEM—SPECIFIC 6.4.3.11.1 Mechanical Electric motor driven chilled-water plants have El measurement devices installed and measure the electricity use and efficiency SYSTEM—SPECIFIC 6.4.3.11.2 Mechanical Electricity use and efficiency are trended every 15 minutes and graphically displayed,including hourly,daily, monthly,and annual data.Data are preserved for 36 months or more. SYSTEM—SPECIFIC 6.5.2.2.2 Mechanical Two-pipe hydronic systems using a common ❑ El distribution system have controls to allow a deadband> 15 OF,allow operation in one mode for at least 4 hrs before changeover,and have rest controls to limit heating and cooling supply temperature to< 30 OF. HVAC 6.5.2.4.1 Mechanical Humidifiers with airstream mounted preheating El El jackets have preheat auto-shutoff value set to activate when humidification is not required. HVAC 6.5.2.4.2 Mechanical Humidification system dispersion tube hot El El surfaces in the airstreams of ducts or air-handling units insulated—R-0.5. HVAC 6.5.2.5 Mechanical Preheat coils controlled to stop heat output El El whenever mechanical cooling, including economizer operation,is active. SYSTEM—SPECIFIC 6.5.3.2.2 Mechanical VAV fans have static pressure sensors positioned El El so setpoint—1.2 in.w.c. design pressure. SYSTEM—SPECIFIC 6.5.4.6 Mechanical Chilled-water and condenser water piping sized according to design flow rate and total annual hours of operation(Table 6.5.4.6). EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 16 of 19 SYSTEM—SPECIFIC 6.5.6.2 Mechanical Condenser heat recovery system that can heat El El water to 85 OF or provide 60%of peak heat rejection is installed for preheating of service hot water. HVAC 6.5.7.2.4 Mechanical Approved field test used to evaluate design air 1:1 El El flow rates and demonstrate proper capture and containment of kitchen exhaust systems. SYSTEM—SPECIFIC 6.5.9 Mechanical Hot gas bypass limited to: < 240 kBtu/h—15% >240 kBtu/h—10% HVAC 6.4.3.9 Mechanical Heating for vestibules and air curtains with integral ❑ heating include automatic controls that shut off the heating system when outdoor air temperatures> 45F.Vestibule heating and cooling systems controlled by a thermostat in the vestibule with heating setpoint—60F and cooling setpoint>_ 80 F. Controls 6.5.10 Mechanical Doors separating conditioned space from the outdoors have controls that disable/reset heating and cooling system when open. Controls 9.4.1.1 except(g) Interior Lighting Automatic control requirements prescribed in Table 9.6.1,for the appropriate space type,are installed.Mandatory lighting controls(labeled as 'REQ')and optional choice controls(labeled as 'ADD1'and'ADD2')are implemented. Controls 9.4.1.1 except(g) Interior Lighting Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Controls 9.4.1.1f Interior Lighting Daylight areas under skylights and roof monitors that have more than 150 W combined input power for general lighting are controlled by photocontrols. Controls 9.4.1.4 Exterior Lighting Automatic lighting controls for exterior lighting installed. Controls 9.4.1.3 Interior Lighting Separate lighting control devices for specific uses installed per approved lighting plans. Wattage 9.6.2 Interior Lighting Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Wattage 9.6.4 Interior Lighting Where space LPD requirements are adjusted based on room cavity ratios,dimensions are consistent with approved plans. Insulation 4.2.4 Envelope Installed roof insulation type and R-value ❑ ❑ ❑ consistent with insulation specifications reported in plans and COMcheck reports. For some ceiling systems,verification may need to occur during Framing Inspection. Insulation 5.8.1.2,5.8.1.3 Envelope Roof insulation installed per manufacturer's ❑ ❑ ❑ instructions. Blown or poured loose-fill insulation is installed only where the ceiling slope is—3:12. Insulation 5.8.1.1 Envelope Building envelope insulation is labeled with El 11 R-value or insulation certificate has been provided listing R-value and other relevant data. Insulation 5.8.1.9 Envelope Building envelope insulation extends over the full area of the component at the proposed rated R or U value. Insulation 5.8.1.4 Envelope Eaves are baffled to deflect air to above the insulation. Insulation 5.8.1.5 Envelope Insulation is installed in substantial contact with the inside surface separating conditioned space from unconditional space. Insulation 5.8.1.6 Envelope Recessed equipment installed in building envelope assemblies does not compress the adjacent insulation. Insulation 5.8.1.7.1 Envelope Attics and mechanical rooms have insulation protected where adjacent to attic or equipment access. Insulation 5.8.1.7.2 Envelope Foundation vents do not interfere with insulation. EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 17 of 19 Insulation 5.8.1.8 Envelope Insulation intended to meet the roof insulation El El F1 requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. SYSTEM—SPECIFIC 6.4.3.1.1 Mechanical Heating and cooling to each zone is controlled by El El El a thermostat control. HVAC 6.4.3.1.2 Mechanical Thermostatic controls have a 5°F deadband. El El HVAC 6.4.3.2 Mechanical Temperature controls have setpoint overlap restrictions. HVAC 6.4.3.3.1 Mechanical HVAC systems equipped with at least one El El El automatic shutdown control. SYSTEM—SPECIFIC 6.4.3.5 Mechanical Heat pump controls prevent supplemental electric resistance heat from coming on when not needed. SYSTEM—SPECIFIC 6.4.3.12 Mechanical Air economizer has a fault detection and diagnostics(FDD)system(see details for configuration and operational requirements). HVAC 6.4.3.6 Mechanical When humidification and dehumidification are provided to a zone,simultaneous operation is prohibited. Humidity control prohibits the use of fossil fuel or electricity to produce RH>30%in the warmest zone humidified and RH<60%in the coldest zone dehumidified. SYSTEM—SPECIFIC 7.4.4.3 Mechanical Public lavatory faucet water temperature< 110°F. SYSTEM—SPECIFIC 7.4.4.4 Mechanical Controls are installed that limit the operation of a ❑ ❑ recirculation pump installed to maintain temperature of a storage tank. SYSTEM—SPECIFIC 7.4.5.1 Mechanical Pool heaters are equipped with on/off switch and ❑ ❑ no continuously burning pilot light. SYSTEM—SPECIFIC 7.4.5.2 Mechanical Pool covers are provided for heated pools and El El pools heated to>90oF have a cover> R-12. SYSTEM—SPECIFIC 7.4.5.3 Mechanical Time switches are installed on all pool heaters and pumps. Wattage 9.2.2.3 Interior Lighting Interior installed lamp and fixture lighting power is El El El consistent with what is shown on the approved lighting plans,demonstrating proposed watts are less than or equal to allowed watts. SYSTEM—SPECIFIC 7.4.3 Mechanical All piping in recirculating system insulated SYSTEM—SPECIFIC 7.4.3 Mechanical First 8 ft of outlet piping in nonrecirculating El El El storage system,or branch piping connected to recirculated, heat traced,or impredance heated piping is insulated. SYSTEM—SPECIFIC 7.4.3 Mechanical All heat traced or externally heated piping insulated Wattage 9.4.4 Interior Lighting At least 75%of all permanently installed lighting El El El fixtures in dwelling units have—55 Im/W efficacy or a—45 Im/W total luminaire efficacy. 4. To be checked by Inspector at Project Completion and Prior to Issuance of Certificate of Occupancy Plan Review 6.7.2.4 Mechanical Detailed instructions for HVAC systems commissioning included on the plans or specifications for projects> 50,000 ft2. Plan Review 6.7.2.4 Mechanical Detailed instructions for HVAC systems commissioning included on the plans or specifications for projects> 50,000 ft2. Post Construction 6.7.2.1 Mechanical Furnished HVAC as-built drawings submitted within 90 days of system acceptance. Post Construction 6.7.2.2 Mechanical Furnished O&M manuals for HVAC systems within El El El 90 days of system acceptance. Post Construction 6.7.2.3 Mechanical An air and/or hydronic system balancing report is El El provided for HVAC systems serving zones>5,000 ft2 of conditioned area. EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 18 of 19 HVAC 6.7.2.4 Mechanical HVAC control systems have been tested to ensure proper operation,calibration and adjustment of controls. Post Construction 8.7.1 Interior Lighting Furnished as-built drawings for electric power El El D systems within 30 days of system acceptance. Post Construction 8.7.2 Interior Lighting Furnished O&M instructions for systems and equipment to the building owner or designated representative. EnergyGauge Summit®Fla/Com-2020. Effective Date: Dec 31,2020 Florida Building Code,Seventh Edition(2020)-Energy Conservation C402.1.2:ASHRAE Prescriptive Compliance Option 7/1/2021 Page 19 of 19 EnergyGauge Summit® v7.00 INPUT DATA REPORT Project Information Project Name: CHILD ADVOCACY Orientation: 0 Deg Clockwise. Walls & Windows ill be rotated accordingly Project Title: 2021-0212 Building Type: Office Address: 8565 COMMERCE CENTER DRIVE Building Classification: Renovation to existing buildiniz State: FLORIDA No.of Stories: 1 Zip: 34968 GrossArea: 8490 SF Owner: - Zones No Acronym Description Type Area Multiplier Total Area lsfl lsfl 1 ZONE 1 Zone 1 CONDITIONED 2302.0 1 2302.0 ❑ 2 ZONE 2 Zone 2 CONDITIONED 1436.0 1 1436.0 ❑ 3 ZONE 3 Zone 3 CONDITIONED 1885.0 1 1885.0 ❑ 4 ZONE 4 Zone 4 CONDITIONED 1657.0 1 1657.0 ❑ 5 ZONE 5 Zone 5 CONDITIONED 1210.0 1 1210.0 ❑ 7/1/2021 EnergyGauge Summit9 v7.00 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] [ft] IN plier [sf] 1cf1 In Zone: ZONE 1 1 ZONE 1 Zo0Sp1 Office-Open Plan 10.00 230.20 9.00 1 2302.0 20718.0 El In Zone: ZONE 2 1 ZONE 2 ZONE 2 Office-Open Plan 10.00 143.60 9.00 1 1436.0 12924.0 El In Zone: ZONE 3 1 ZONE 3 ZONE 3 Office-Open Plan 10.00 188.50 9.00 1 1885.0 16965.0 El In Zone: ZONE 4 1 ZONE 4 ZONE 4 Office-Open Plan 10.00 165.70 9.00 1 1657.0 14913.0 El In Zone: ZONE 5 1 ZONE 5 ZONE 5 Office-Open Plan 10.00 121.00 9.00 1 1210.0 10890.0 ❑ Lighting No Type Category No.of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: ZONE 1 In Space: ZONE 1 1 LED General Lighting 21 34 714 Occupancy sensor without 8 ❑ Daylighting 2 LED General Lighting 3 14 42 Occupancy sensor without 1 El Daylighting In Zone: ZONE 2 In Space: ZONE 2 1 LED General Lighting 20 34 680 Occupancy sensor without 8 ❑ Daylighting 2 LED General Lighting 5 14 70 Occupancy sensor without 1 Daylighting In Zone: ZONE 3 In Space: ZONE 3 7/1/2021 EnergyGauge Summit9 v7.00 2 I LED General Lighting 33 34 1122 Occupancy sensor without 1 ❑ Daylighting In Zone: ZONE 4 In Space: ZONE 4 1 LED General Lighting 25 34 850 Occupancy sensor without 9 ❑ Daylighting In Zone: ZONE 5 In Space: ZONE 5 1 LED General Lighting 15 34 510 Occupancy sensor without 7 ❑ Daylighting Walls (Walls will be rotated clockwise by building rotation value) No Description Type Width H(Effec) Multi Area Orientation Conductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr.sf.F] Capacity [lb/cf] [h.sf.F/Btu] [Btu/sLF] In Zone: Windows (Windows will be rotated clockwise by building rotation value) No Description Orientation Shaded U SHGC Vis.Tra W H(Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sq In Zone: In Wall: Doors No Description Type Shaded? Width H(Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN IN plier [sf] [Btu/hr.sL F] [lb/cf] [Btu/sL F] [h.sLF/Btu] In Zone: In Wall: 7/1/2021 EnergyGauge Summit©v7.00 3 Roofs No Description Type Width H(Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value N N plier [s11 [deg] [Btu/hr.St F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] In Zone: EJ Skylights No Description Type U SHGC Vis.Trans W H(Effec) Multiplier Area Total Area [Btu/hr sf F] [ft] [ft] [Sf] [Sf] In Zone: In Roof: Floors No Description Type Width H(Effec) Multi Area Cond. Heat Cap. Dens. R-Value N [ft] plier [sf] [Btu/hr.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] In Zone: ZONE 1 1 ZONE 1 1 ft. soil,concrete 230.20 10.00 1 2302.0 0.2681 34.00 113.33 3.73 ❑ floor,carpet and rubber pad In Zone: ZONE 2 1 ZONE 2 1 ft. soil,concrete 143.60 10.00 1 1436.0 0.2681 34.00 113.33 3.73 ❑ floor,carpet and rubber pad In Zone: ZONE 3 1 ZONE 3 1 ft. soil,concrete 188.50 10.00 1 1885.0 0.2681 34.00 113.33 3.73 ❑ floor,carpet and rubber pad In Zone: ZONE 4 7/1/2021 EnergyGauge Summit9 v7.00 4 I ZONE 4 1 ft. soil,concrete 165.70 10.00 1 1657.0 0.2681 34.00 113.33 3.73 ❑ floor,carpet and rubber pad In Zone: ZONE 5 1 ZONE 5 1 ft. soil,concrete 121.00 10.00 1 1210.0 0.2681 34.00 113.33 3.73 ❑ floor,carpet and rubber pad Systems RTU 1 ZONE 1 Constant Volume Packaged No. Of Units 1 System--902 Component Category Capacity Efficiency IPLV 1 Cooling System 57900.00 14.00 8.00 ❑ 2 Heating System 25590.00 1.00 ❑ 3 Air Handling System-Supply 2000.00 0.80 ❑ RTU 2 ZONE 2 Constant Volume Air Cooled Split No. Of Units 1 System<65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 46000.00 14.00 8.00 ❑ 2 Heating System 25590.00 1.00 ❑ 3 Air Handling System-Supply 1600.00 0.80 ❑ RTU 3 System 3 Constant Volume Air Cooled Split No. Of Units 1 System<65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 40000.00 14.00 8.00 ❑ 2 Heating System 25590.00 1.00 ❑ 3 Air Handling System-Supply 1400.00 0.80 ❑ 7/1/2021 EnergyGauge SummiM v7.00 5 RTU 4 ZONE 4 Constant Volume Air Cooled Split No. Of Units 1 System<65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 46000.00 14.00 8.00 ❑ 2 Heating System 25590.00 1.00 ❑ 3 Air Handling System-Supply 1600.00 0.80 ❑ RTU 5 ZONE 5 Constant Volume Packaged No. Of Units l System--902 Component Category Capacity Efficiency IPLV 1 Cooling System 57900.00 14.00 8.00 ❑ 2 Heating System 25590.00 1.00 ❑ 3 Air Handling System-Supply 2000.00 0.80 ❑ Plant Equipment Category Size Inst.No Eff. IPLV LI Water Heaters W-Heater Description CapacitiCap.Unit I/P Rt. Efficiency Loss 1 Electric Storage water heater 30 [Gal] 5 [M] 0.9600 [Ef] [Btu/h] ❑ Ext-Lighting Description Category No.of Watts per Area/Len/No.of units Control Type Wattage Luminaires Luminaire [sf/ft/No] [W] 7/1/2021 EnergyGauge Summit©v7.00 6 Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F] [Btu-in/h.sf.F] [in] [in] Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] El Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.F/Btu] [ft] [Btu/h.ft.F] [lb/cf] [Btu/1b.F] 178 at es 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in.Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1057 1 ft. soil,concrete floor,carpet and rubber No No 0.27 34.00 113.33 3.7 ❑ pad Layer Material Material Thickness Framing No. [ft] Factor 7/1/2021 EnergyGauge SummitR v7.00 7 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1057 1 ft. soil,concrete floor,carpet and rubber No No 0.27 34.00 113.33 3.7 ❑ pad Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in.Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ 7/1/2021 EnergyGauge Summit9 v7.00 8 Air System Sizing Summary for RTU 1 Project Name:CHILDREN'S ADVOCACY 2021-0212 06/23/2021 Prepared by: Kamm Consulting 10:31AM Air System Information Air System Name-- RTU 1 Number of zones ---- -------1 Equipment Class PKG ROOF Floor Area 2302.0 ft2 Air System Type............................................................SZCAV Location------------------------------------------ PORT ST.LUCIE,Florida Sizing Calculation Information Calculation Months_______________________Jan to Dec Zone CFM Sizing_____ Sum of space airflow rates Sizing Data___________________________User-Modified Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 5.0 Tons Load occurs at Sep 1400 Total coil load------ ------------59.7 MBH OADB/WB-- 88.6/76.9 OF Sensible coil load 46.0 MBH Entering DB/WB 76.3/64.2 OF Coil CFM at Sep 1400......................................................2000 CFM Leaving DB/WB.........................................................55.0/53.9 OF Max block CFM 2000 CFM Coil ADP 52.6 OF Sum of peak zone CFM----------- --------2000 CFM Bypass Factor 0.100 Sensible heat ratio 0.770 Resulting RH 51 % ft2/Ton.................................................................. 463.0 Design supply temp.------------------------------------ 55.0 OF BTU/(hr-ft2) 25.9 Zone T-stat Check 0 of 1 OK Water flow @ 10.0 OF rise___________________ N/A Max zone temperature deviation___________ 3.7 OF Central Heating Coil Sizing Data Max coil load--------------------------------------------------------------------11.7 MBH Load occurs at_______________________________.. Des Htg Coil CFM at Des Htg 2000 CFM BTU/(hr-ft2) 5.1 Max coil CFM --- -----------2000 CFM Ent.DB/Lvg DB -------------------- 65.8/71.2 OF Water flow @ 20.0 OF drop N/A Supply Fan Sizing Data Actual max CFM 2000 CFM Fan motor BHP 0.00 BHP Standard CFM ----- -----------1999 CFM Fan motor kW ----0.00 kW Actual max CFM/ft2 0.87 CFM/ft2 Fan static 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 158 CFM CFM/person 39.53 CFM/person CFM/ft2 0.07 CFM/ft2 Hourly Analysis Program v5.01 Page 1 of 5 Air System Sizing Summary for RTU 2 Project Name:CHILDREN'S ADVOCACY 2021-0212 06/23/2021 Prepared by: Kamm Consulting 10:31AM Air System Information Air System Name-- RTU2 Number of zones --------- --------1 Equipment Class PKG ROOF Floor Area 1436.0 ft2 Air System Type............................................................SZCAV Location------------------------------------------ PORT ST.LUCIE,Florida Sizing Calculation Information Calculation Months_______________________Jan to Dec Zone CFM Sizing_____ Sum of space airflow rates Sizing Data_______________________________Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 4.0 Tons Load occurs at Jun 1400 Total coil load------ ------------47.9 MBH OADB/WB-- 89.6/77.9 OF Sensible coil load 38.5 MBH Entering DB/WB 72.0/61.7 OF Coil CFM at Jun 1400------------------------------------------------------1991 CFM Leaving DB/WB.........................................................54.1 /53.2 OF Max block CFM 1991 CFM Coil ADP 52.1 OF Sum of peak zone CFM----------- 1991 CFM Bypass Factor 0.100 Sensible heat ratio 0.804 Resulting RH 55 % ft2/Ton.................................................................. 360.1 Design supply temp.------------------------------------ 55.0 OF BTU/(hr-ft2) 33.3 Zone T-stat Check 1 of 1 OK Water flow @ 10.0 OF rise___________________ N/A Max zone temperature deviation___________ 0.0 OF Central Heating Coil Sizing Data Max coil load--------------------------------------------------------------------15.0 MBH Load occurs at_______________________________..Apr 0500 Coil CFM at Apr 0500 1991 CFM BTU/(hr-ft2) 10.4 Max coil CFM --- -----------1991 CFM Ent.DB/Lvg DB -----------------------------54.2/61.1 OF Water flow @ 20.0 OF drop N/A Supply Fan Sizing Data Actual max CFM 1991 CFM Fan motor BHP 0.00 BHP Standard CFM ----- -----------1989 CFM Fan motor kW ----0.00 kW Actual max CFM/ft2 1.39 CFM/ft2 Fan static 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 106 CFM CFM/person 26.54 CFM/person CFM/ft2 0.07 CFM/ft2 Hourly Analysis Program v5.01 Page 2 of 5 Air System Sizing Summary for RTU 3 Project Name:CHILDREN'S ADVOCACY 2021-0212 06/23/2021 Prepared by: Kamm Consulting 10:31AM Air System Information Air System Name-- RTU 3 Number of zones --------- --------1 Equipment Class PKG ROOF Floor Area 1885.0 ft2 Air System Type............................................................SZCAV Location------------------------------------------ PORT ST.LUCIE,Florida Sizing Calculation Information Calculation Months_______________________Jan to Dec Zone CFM Sizing_____ Sum of space airflow rates Sizing Data_______________________________Calculated Space CFM Sizing________Individual peak space loads Central Cooling Coil Sizing Data Total coil load 5.0 Tons Load occurs at Jun 1500 Total coil load------ ------------59.4 MBH OADB/WB-- 90.0/78.0 OF Sensible coil load 47.4 MBH Entering DB/WB 72.4/62.0 OF Coil CFM at Jun 1500------------------------------------------------------2432 CFM Leaving DB/WB.........................................................54.4/53.4 OF Max block CFM 2432 CFM Coil ADP 52.4 OF Sum of peak zone CFM----------- --------2432 CFM Bypass Factor 0.100 Sensible heat ratio 0.797 Resulting RH 55 % ft2/Ton.................................................................. 380.5 Design supply temp.------------------------------------ 55.0 OF BTU/(hr-ft2) 31.5 Zone T-stat Check 1 of 1 OK Water flow @ 10.0 OF rise___________________ N/A Max zone temperature deviation___________ 0.0 OF Central Heating Coil Sizing Data Max coil load--------------------------------------------------------------------19.2 MBH Load occurs at_______________________________..Jan 0800 Coil CFM at Jan 0800 2432 CFM BTU/(hr-ft2) 10.2 Max coil CFM --- -----------2432 CFM Ent.DB/Lvg DB -----------------------------54.2/61.5 OF Water flow @ 20.0 OF drop N/A Supply Fan Sizing Data Actual max CFM 2432 CFM Fan motor BHP 0.00 BHP Standard CFM ----- -----------2430 CFM Fan motor kW ----0.00 kW Actual max CFM/ft2 1.29 CFM/ft2 Fan static 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 143 CFM CFM/person 23.85 CFM/person CFM/ft2 0.08 CFM/ft2 Hourly Analysis Program v5.01 Page 3 of 5 Air System Sizing Summary for RTU 4 Project Name:CHILDREN'S ADVOCACY 2021-0212 06/23/2021 Prepared by: Kamm Consulting 10:31AM Air System Information Air System Name-- RTU4 Number of zones --------- --------1 Equipment Class PKG ROOF Floor Area 1657.0 ft2 Air System Type............................................................SZCAV Location------------------------------------------ PORT ST.LUCIE,Florida Sizing Calculation Information Calculation Months_______________________Jan to Dec Zone CFM Sizing_____ Sum of space airflow rates Sizing Data_______________________________Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 3.5 Tons Load occurs at Jun 1500 Total coil load------ ------------42.3 MBH OADB/WB-- 90.0/78.0 OF Sensible coil load 36.7 MBH Entering DB/WB 72.2/61.8 OF Coil CFM at Jun 1500------------------------------------------------------2056 CFM Leaving DB/WB.........................................................55.6/54.7 OF Max block CFM 2056 CFM Coil ADP 53.8 OF Sum of peak zone CFM----------- 2056 CFM Bypass Factor 0.100 Sensible heat ratio 0.870 Resulting RH 55 % ft2/Ton.................................................................. 470.5 Design supply temp.------------------------------------ 55.0 OF BTU/(hr-ft2) 25.5 Zone T-stat Check 1 of 1 OK Water flow @ 10.0 OF rise___________________ N/A Max zone temperature deviation___________ 0.0 OF Central Heating Coil Sizing Data Max coil load--------------------------------------------------------------------16.2 MBH Load occurs at_______________________________..Jan 0400 Coil CFM at Jan 0400 2056 CFM BTU/(hr-ft2) 9.8 Max coil CFM --- -----------2056 CFM Ent.DB/Lvg DB -------------------- 55.4/62.7 OF Water flow @ 20.0 OF drop N/A Supply Fan Sizing Data Actual max CFM 2056 CFM Fan motor BHP 0.00 BHP Standard CFM ----- -----------2054 CFM Fan motor kW ----0.00 kW Actual max CFM/ft2 1.24 CFM/ft2 Fan static 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 114 CFM CFM/person 38.14 CFM/person CFM/ft2 0.07 CFM/ft2 Hourly Analysis Program v5.01 Page 4 of 5 Air System Sizing Summary for RTU 5 Project Name:CHILDREN'S ADVOCACY 2021-0212 06/23/2021 Prepared by: Kamm Consulting 10:31AM Air System Information Air System Name-- RTU 5 Number of zones --------- --------1 Equipment Class PKG ROOF Floor Area 1210.0 ft2 Air System Type............................................................SZCAV Location------------------------------------------ PORT ST.LUCIE,Florida Sizing Calculation Information Calculation Months_______________________Jan to Dec Zone CFM Sizing_____ Sum of space airflow rates Sizing Data_______________________________Calculated Space CFM Sizing________Individual peak space loads Central Cooling Coil Sizing Data Total coil load 4.1 Tons Load occurs at Jun 1400 Total coil load------ ------------48.8 MBH OADB/WB-- ------ 89.6/77.9 OF Sensible coil load 39.7 MBH Entering DB/WB 71.8/61.5 OF Coil CFM at Jun 1400------------------------------------------------------2071 CFM Leaving DB/WB.........................................................54.1 /53.2 OF Max block CFM 2071 CFM Coil ADP 52.1 OF Sum of peak zone CFM----------- 2071 CFM Bypass Factor 0.100 Sensible heat ratio 0.812 Resulting RH 55 % ft2/Ton.................................................................. 297.4 Design supply temp.------------------------------------ 55.0 OF BTU/(hr-ft2) 40.3 Zone T-stat Check 1 of 1 OK Water flow @ 10.0 OF rise___________________ N/A Max zone temperature deviation___________ 0.0 OF Central Heating Coil Sizing Data Max coil load--------------------------------------------------------------------16.8 MBH Load occurs at...............................................................May 0400 Coil CFM at May 0400 2071 CFM BTU/(hr-ft2) 13.9 Max coil CFM --- 2071 CFM Ent.DB/Lvg DB -----------------------------54.2/61.7 OF Water flow @ 20.0 OF drop N/A Supply Fan Sizing Data Actual max CFM 2071 CFM Fan motor BHP 0.00 BHP Standard CFM ----- -----------2069 CFM Fan motor kW ----0.00 kW Actual max CFM/ft2 1.71 CFM/ft2 Fan static 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 103 CFM CFM/person 17.10 CFM/person CFM/ft2 0.08 CFM/ft2 Hourly Analysis Program v5.01 Page 5 of 5