HomeMy WebLinkAboutP0-1 PLUMBING FIXTURE SCHEDULE PLUMBING NOTES PLUMBING SHEET INDEX
HANDICAP LAVATORY, AMERICAN STANDARD, LUCERNE WALL HUNG LAVATORY MODEL #0356.028. 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY FOR THE SHILL
EET# DESC;RIP110N
HLAV WHITE, WITH T&S BRASS FAUCET BS-2701-VF05. CONTRACTOR TO SUPPLY CONCEALED ARM SUPPOR INSTALLATION OF A COMPLETE SCOPE OF WORK. ALL WORKMANSHIP AND MATERIALS SHALL BE IN
SUPPORT CARRIER FOR MOUNTING OF LAV. WADE MODEL # 520-M36. SUPPLY PLUMBEREX MODEL STRICT ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION 2017 - PLUMBING,
#4333 INSULATION KIT. MUST MEET A.D.A. CODE. APPLICABLE LOCAL CODES, RULES, AND ORDINANCES. ( ) P0.1 PLUMBING NOTES, LEGENDS, AND DETAILS
HANDICAP WATER CLOSET, AMERICAN STANDARD #215AA.004 FLOOR MOUNTED, WHITE, CENTOCO SEAT 2. PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL P2.1 SANITARY PLAN
V,
ARCHITECTS D E S I G N
HWC #500CC, OPEN FRONT WITH COVER. EXISTING CONDITIONS. P3.1 DOMESTIC WATER PLAN COLLABORATIVE , L L c
A.D.A EL 1.28 ELONGATED 18" HIGH OR EQUAL.
ASSE 1070 COMPLIANT 3. ALL MATERIALS SHALL BE NEW AND OF GOOD QUALITY. ARCHITECTURE I URBAN DESIGN
THERMOSTATIC MIXING VALVE HUR URINAL AMERICAN STANDARD, ALLBROOK #6541.132. FLUSH VALVE, SLOAN ROYAL #186-1, WALL P5.1 PLUMBING ISOMETRICS
4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS PLANNING I INTERIORS
EQUAL TO LEONARD MODEL MOUNTED, WHITE URINAL. WALL CARRIER, WADE # 400AM11-M36. MUST MEET A.D.A. CODE. WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY-OPERATIONAL. ALL EXCAVATION 10489 SOUTHWEST MEETINGST
#170-LF-BRKT. SET @ 105'F. AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS TRADITION,
TEMPERED COLD HANDICPPED SHOWER, MIXING VALVE HOT AND COLD WATER, SHOWER MIXING VALVE SHALL BE A CONTRACT. Pei.jii2j 2se 9ooa987
IN-LINE FLOW CONTROL HSH SYMMONS ORIGIN MODEL #9603-PLR TEMPTROL PRESSURE BALANCED SHOWER
VALVE TO INCLUDE A 2.5 GPM FLOW RESTRICTOR AND INTEGRAL SERVICE STOPS. 5. REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR FOR PROTECTION PLUMBING LEGEND www• ADC-ARCHITECTS.NET
MOUNTING FLANGES (4) AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK.
REGISTRATIONS HELD IN THE FOLLOWING STATES:
FD FLOOR DRAIN, WADE MODEL 1103-TY-STD5. CALIFORNIA,COLORADO, FLORIDA
TANKLESS WATER HEATER HOT 3/8" COPPER TUBING # 6. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTS. GEORGIA, NORTH CAROLINA
SET LESS PLUMBING CONTRACTOR SHALL OBTAIN PERMIT AND APPROVED SUBMITTALS PRIOR TO BEGINNING MISSISSIPPI,TEXAS
WORK OR ORDERING EQUIPMENT. PLUMBING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS CO CLEAN OUT �� SANITARY SEWER PIPING
SINGLE STAINLESS STEEL SINK, 25 X 22 DAYTON MODEL #K-12522 WITH A ARCHITECTURE
JUNCTION SK T&S BRASS FAUCET MODEL #B-0199-01-N05 WITH A 5-11/16" SPREAD GOOSENECK OF HIS WORK BY REGULATORY AUTHORITIES.
� HOTWITH 4" WRIST BLADE FAUCET HANDLES. S.O.V. SHUT-OFF VALVE � - - - � VENT PIPING URBAN DESIGN
BOX 11/2" FULL OPEN SHUT OFF 7. CONTRACTOR SHALL SUBMIT TO ARCHITECT/ENGINEER, FOR REVIEW & APPROVAL, FIVE (5) SETS OF PLANNING INTERIORS
COLD VALVE FIAT MSB MODEL # 2424 MOLDED TERRAZZO BASIN WITH DRAIN BODY AND STRAINER. MANUFACTURER'S CUT SHEETS FOR EACH FIXTURE, PIPING/FITTING MATERIAL AND EQUIPMENT ITEM COTC CLEAN OUT TO GRADE - DOMESTIC COLD WATER PIPING
COLD MOP FIAT SERVICE SINK FAUCET MODEL #830-AA, WITH FIAT 832-AA HOSE AND HOSE BRACKET WITH ASSOCIATED CONTROLS, THAT ARE INCLUDED IN THE CONTRACT. THESE DRAWINGS ARE INSTRUMENTS OF SERVICE.
SK DISCHARGE; PAIL HOOK AND TOP BRACE; VACUUM BREAKER, FIAT #889-CC MOP HANGER AND FS FLOOR SINK -- HOT WATER PIPING (110') P RESERVES ITS ITDESIGN MCOLLABORATIVE,IGHT AND OTHER
:4)
A BP SPLASH CATCHER WALL GUARD. 8. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, PROPERTY RIGHTS IN THESE PLANS, SPECIFICATIONS.
LT COMPRESSION FITTINGS (2) EQUIPMENT, ETC. CW DOMESTIC COLD WATER --- HOT WATER PIPING (140') DESIGNS A"° IDEAS. T"ESE
PLANS, SPECIFICATIONS, DESIGNS AND IDEAS ARE
HANDICAP/DRINKING FOUNTAIN, ELKAY BI-LEVEL WALL MOUNTED NOT TO BE C°APPROVAL of ARCHITECT WITHOUT WRITTEN
HDF/DF BARRIER FREE MODEL # EZSTL8C.7.8 GPH, WADE 440-AM11-M36 9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE HW DOMESTIC HOT WATER --- HOT WATER RECIRCULATING PIPING THESE DRAWINGS ARE NOT TO BE SCALED (WRITTEN
CARRIER AS REQUIRED. 115V, 4.5 A, MUST MEET A.D.A. CODE. PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ARCHITECT/ENGINEER PRIOR TO DIMENSIONS SHALL GOVERN). ANY DISCREPANCY
BEGINNING CONSTRUCTION. HWR DOMESTIC HOT WATER RECIRCULATING CD� CONDENSATE PIPING BBE WEENY THEM AND RIELDA CONOPTIOINSG SHAALLLL BED
INSTANTANEOUS WATER HEATER IWH TANKLESS WATER HEATER SHALL BE CHRONOMITE MODEL # SR-20L 120V, 1 RESOLVED IN WRITING THIRD THIS OFFICE (772) 286
9004. THESE PLANS ARE NOT TO BE SUBMITTED FOR
PHASE, 1.8 KW. 10. VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERT ELEVATIONS OF ALL EXISTING UTILITIES HB HOSE BIBB CA COMPRESSED AIR PIPING PERMIT UNLESS SIGNED & SEALED BY ARCHITECT.
CONNECTIONS FOR PUBLIC LAVATORIES EWH WATER HEATER SHALL BE 30 GAL. ELECTRIC 208V, 1 PHASE, 4.5 KW. PRIOR TO BEGINNING OF CONSTRUCTION. ADVISE ARCHITECT/ENGINEER OF ANY DISCREPANCIES.
LOCHINVAR SHORT MODEL LSA-030-KD. VTR VENT THRU ROOF T&P TEMPERATURE AND PRESSURE RELIEF
NOT TO SCALE RECIRC TACO RECIRC. PUMP. MODEL 111 BRONZE CASTING , 115V, 1/8 HP, 2.0 AMP WITH 11. WATER DISTRIBUTION PIPING ABOVE AND BELOW GROUND SHALL BE TYPE "L" COPPER. ALTERNATE
PUMP 00 TIMER AQUSTAT. PIPING & FITTING MATERIALS MAY BE USED IN ACCORDANCE WITH FLORIDA BUILDING CODE 6TH GATE VALVE SD STORM DRAIN PIPING
EDITION (2017) - PLUMBING, TABLES 605.3, 605.4 & 605.5, WHEN APPROVED BY ENGINEER OF
RECORD AND LOCAL AUTHORITY HAVING JURISDICTION. PROVIDE ALTERNATE FOR CPVC PIPING & Do4 GLOBE VALVE G GAS PIPING
GENERAL NOTES: FITTINGS EQUAL TO LUBRIZOL CORZAN OR FLOW-GUARD GOLD. PROVIDE ALTERNATE FOR PEX TYPE
(1) - FIXTURES SHALL BE AS SHOWN OR EQUAL. 'A' PIPING & FITTINGS EQUAL TO UPONOR. ALTERNATES ARE PERTINENT FOR WATER SERVICES N CHECK VALVE S--o-S PIPE RISE UP
(2) - ALL FIXTURES SHALL COMPLY WITH TABLE 604.4 OF FBC 2017 KNOWN OR DETERMINED TO HAVE ACIDIC CHARACTERISTICS OR OTHER PARTICULAR CIRCUMSTANCES
(3) - ALL FIXTURE TRIM PACKAGES INCLUDING BUT NOT LIMITED TO TRAP, ANGLE STOP, FLUSH VALVE, AS DEEMED APPROPRIATE BY DIRECTIVE FROM THE OWNER. CONTRACTOR SHALL PERFORM A WATER Dd GAS SOLENOID VALVE �_D-S PIPE DOWN OR DROP
SUPPLY TUBES, AND CLEANOUT COVER PLATES SHALL BE OF THE SAME FINISH AS THE ABOVE TEST TO DETERMINE WATER CHEMISTRY PRIOR TO ANY WORK OR PIPING INSTALLATION AND SHALL
SPECIFIED FAUCET AND PER ARCHITECTURAL FINISH SCHEDULE. SUBMIT TEST RESULTS TO THE ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL. DISINFECTION OF GAS COCK E CAPPED END OF PIPE REVISIONS:
(4) - ALL FIXTURES SHALL BE ROUGHED IN PER MANUFACTURER CUT SHEET TO MAINTAIN UNIFORMITY. POTABLE WATER SYSTEM SHALL COMPLY WITH FLORIDA BUILDING CODE 6TH EDITION (2017) - n# No. Description Date
PLUMBING, SECTION 610. ALL WATER PIPING & FITTINGS SHALL BE OF DOMESTIC MANUFACTURE; ITI WATER HAMMER ARRESTER (PDI No.) POINT OF CONNECTION
SPECIFICALLY IN THE UNITED STATES OF AMERICA.
® FD FLOOR DRAIN � P-TRAP
12. SOIL, WASTE, VENT, AND RAINWATER (DWV) PIPING & FITTINGS SHALL BE CAST IRON OR PVC, WHERE
HEAT TRAP EXPANSION VALVE COLD WATER SUPPLY CODE ALLOWS. PVC MAY NOT BE USED THRU RATED ASSEMBLIES OR IN PLENUMS. PVC PIPING
(OMIT IF HEAT TRAP IS AN TO WATER HEATER. SHALL BE SOLID-CORE ONLY; FOAM-CORE PIPING SHALL NOT BE ACCEPTED. CAST IRON PIPING &
INTEGRAL PART OF HEATER) PROVIDE A 210'F TEMPERATURE AND FITTINGS SHALL BEAR THE CISPI-301 MARK. ALL DWV PIPING & FITTINGS SHALL BE OF DOMESTIC
HOT WATER TO FIXTURES 150 PSI PRESSURE RELIEF VALVE MANUFACTURE; SPECIFICALLY IN THE UNITED STATES OF AMERICA.
AS SHOWN ON PLANS FWITH TEST LEVER SIZED WITH AGA/CGA
TEMPERATURE STEAM RATING 10% OVER 13. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE ANGLE STOPS AND APPROPRIATELY
HEATER INPUT MARKED ACCESS PANELS (WHERE REQUIRED). COORDINATE LOCATIONS WITH GENERAL CONTRACTORFTF
OVIDE TEST TEEP
PROVIDE A HARD PRIOR TO INSTALLATION. TH SCREWED COUNTER- I I
COLUMN OR PARTITION
PROVIDE FULL PORT BALL NK ABS PLASTIC PLUG: I AS SHOWN ON FLOOR PLAN
COPPER RELIEF 14. PROVIDE APPROVED WATER HAMMER ARRESTORS FOR ALL GROUP PLUMBING FIXTURES, SIZED & PERED-THREAD WITH I CLEANOUT FACE SHALL
SHUTOFF VALVES VALVE DISCHARGE ( ) E JOINT COMPOUND. "LINE FULL SIZE OF LOCATED PER MANUFACTURERS INSTALLATION INSTRUCTIONS & PDI-WH2O1. -j BE WITHIN 4 OF WALL
PROVIDE PIPE UNIONS, SURFACE. PROVIDE
DIELECTRIC IF REQUIRED FOR VALVE OUTLET RUN 15. PROVIDE DIELECTRIC COUPLINGS OR FLANGES BETWEEN ALL DISSIMILAR METALS IN PIPING AND ERE CLEANOUT TEE _ PIPE EXTENSION IF REQUIRED.
DISSIMILAR METALS. it TO INDIRECT WASTE EQUIPMENT CONNECTIONS. IS CONCEALED IN A
IN SAME ROOM OR CHASE OR PARTITION, -
TO OUTSIDE BUILDING 16. ISOLATE COPPER PIPING FROM METALLIC HANGERS OR SUPPORTS WITH ISOLATOR PADS OR PROVIDE A ROUND 18 I I
ATTACH STRAP W/ 6" ABOVE GRADE WITH NON-CONDUCTIVE MATERIAL. GAUGE STAINLESS STEEL
3/8" LAG SCREWS 1/3H A VISIBLE AIR GAP IN COVER WITH BEVELED i I
SAME ROOM PER FLORIDA 17. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, EDGES AND FLATHEAD
INTO BLOCKING OR BUILDING CODE 2014 SEC. SMOKE AND WATER PENETRATION BY FILLING ANNULAR SPACE BETWEEN PIPING AND SLEEVES WITH MACHINE SCREW.
STUDS 506.7.1 INTUMESCENT CAULK, TO ACHIEVE THE SAME RATING AS WALLS OR FLOORS, AS PART OF THE
I I
2" 16 GAGE STRAP PLUMBING CONTRACTOR'S WORK. I I
AROUND HEATER DRAIN VALVE BY
2/3H HEATER MANUFACT. 18. PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS a
THERMOSTAT AND PRESSURE 1/2" PLYWOOD PLATFORM FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE BY OWNER. CONCRETE
REGULATOR FURNISHED 0 ABOVE MOP SINK ® 8'-0"AFF CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL FLOOR
WITH WATER HEATER. - -- V.I.F. MOUNTING HEIGHT W/LOCAL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE SLAB
Z. BLDG. OFFICIAL & ARCHITECT. BEEN DAMAGED.
DRAIN PAN WITH
MINIMUM 2" HIGH SIDES B-LINE FIG. B3066 19. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES. ACCESS PANELS IN RATED WALLS SHALL
STUD WALL ANGLE BRACKET (TYP.2) MAINTAIN THE SAME RATING AND SHALL MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED.
PROVIDE A DRAIN PAN, RUN OVERFLOW 20. PROVIDE COMBINATION CLEANOUT PLUG AND COVER PLATE OR ACCESS PANEL FOR ALL WALL
2x BLOCKING BETWEEN 2'-0" LINE TO EXTERIOR OF BUILDING AT 6 CLEANOUTS. FINISH TO MATCH NEARBY FIXTURE TRIM. NOTE:
STUDS (TYP) ABOVE GRADE OR NEAREST APPROVED
INDIRECT WASTE. PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES
21. NO COMBUSTIBLE MATERIAL SHALL BE INSTALLED IN MECHANICAL ROOMS NOR IN CEILING SPACES NOT SERVED WITH A FLOOR CLEANOUT: LOCATE ABOVE FIXTURE FLOOD RIM
WHERE USED AS RETURN AIR PLENUMS.3/8" LAG SCREW (4 MIN.) WITHIN 4' OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. w
INTO BLOCKING OR STUDS 22. NO WATER, SANITARY OR DRAINAGE PIPING SHALL BE INSTALLED IN ELECTRICAL OR ELEVATOR
EQUIPMENT ROOMS. I-I--i
PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT 23. ALL CONTROL VALVES SHALL BE TAGGED AND MARKED. A REPRODUCIBLE DIAGRAM LOCATING ALL w H
FIELD CONDITIONS. REFER TO ISOMETRIC RISER FOR PIPE SIZES. VALVES SHALL BE FURNISHED FOR OWNER/OPERATOR. Imo, Q0
SET HEATER THERMOSTAT AT 120' F. PROVIDE MIXING VALVES r
AS REQUIRED AT LAVATORIES TO COMPLY WITH FBC ENERGY 504.3. 24. CONDENSATE DRAIN PIPING SHALL BE TYPE "L" COPPER WITH ARMAFLEX INSULATION AND A WALL CLEANOUT DETAIL M
J
VAPOR BARRIER JACKET PER FLORIDA BUILDING CODE 6TH EDITION (2017) - ENERGY NOT TO SCALE p.., m
PLATFORM MOUNTED WATER HEATER DETAIL
CONSERVATION, TABLE C403.2.8. PVC WITHOUT INSULATION IS ACCEPTABLE FOR RISERS AND BELOW w
NOT TO SCALE GRADE PIPING. WHEN USED IN A RETURN AIR PLENUM, PVC PIPING WITH INSULATION IS ACCEPTABLE L)
IN LOCATIONS WHERE ALLOWED BY LOCAL CODES. CONDENSATE PIPING SHALL NOT DRAIN ONTO THE J
ROOFING SYSTEM NOR ANY OF ITS COMPONENTS. CONDENSATE PIPING ARRANGEMENT IS EXEMPT SHOCK ARRESTOR SCHEDULE w �/ Cn
FROM MINIMUM EQUIPMENT CLEARANCE REQUIREMENTS PER FLORIDA BUILDING CODE 6TH EDITION
(2017), SECTION 1522.3.5. ALL HORIZONTAL RAINWATER PIPING RUN ABOVE FINISHED FLOOR THAT of
RECEIVES CONDENSATE DISCHARGE SHALL BE INSULATED WITH ARMAFLEX AND A VAPOR-BARRIER P.D.I. DESIGNATION MANUF. & MODEL FIXTURE UNITS CONNECTION w
JACKET. / 0 ^ �
A SIOUX CHIEF 652-A 1-11 1 2" {-I w
25. HOT WATER PIPING INSULATION SHALL BE PROVIDED IN ACCORDANCE WITH FLORIDA BUILDING CODE U) 0
6TH EDITION (2017) - PLUMBING, TABLE 607.5 & FLORIDA BUILDING CODE 6TH EDITION (2017) - B SIOUX CHIEF 653-B 12-32 3/4" Z 0
ENERGY CONSERVATION, TABLE C403.2.8. CONTRACTOR SHALL USE ARMAFLEX OR EQUAL WHERE
Lu
APPLICABLE. WHERE DOMESTIC WATER TEMPERATURES CAN CAUSE SWEATING, ALL COLD WATER C SIOUX CHIEF 654-C 33-60 1" z
PIPING SHALL BE INSULATED WITH ARMAFLEX INSULATION AND A VAPOR-BARRIER JACKET, PER
FLORIDA BUILDING CODE 6TH EDITION (2017) - ENERGY CONSERVATION, TABLE C403.2.8. SIOUX CHIEF SHOCK ARRESTORS APPROVED FOR INSTALLATION WITH NO UO H w ACCESS DOOR REQUIRED. CONFORMS TO ANSI/ASSE 1010 STANDARDS.
26. AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO VENT PIPING THRU ROOF WHERE
ACCEPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION. INSTALLATION METHODS SHALL BE IN SLOPE OF HORIZ. DRAINAGE PIPE LU
LU
ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS. Q U) �
27.PROVIDE ANGLE STOPS ON ALL WATER SERVICE LINES TO FIXTURES FOR INDIVIDUAL Q� LU 0
SHUT-OFF. SIZE (inches) MINIMUM SLOPE (inch per foot) Z � CU
0 DO
28•STUDOR MINI/MAXI AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO 2-1/2 or less 1/4 OU < 00
VENT PIPING THRU ROOF WHERE ACCEPTABLE BY THE PLUMBING OFFICIAL AND LOCAL Q
CODES. INSTALLATION SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS. 3 to 6 1/8
29.ALL HORIZONTAL RAINWATER PIPING THE RECEIVES CONDENSATE DISCHARGE FROM AIR DWG IDENTIFICATION
CONDITIONING EQUIPMENT SHALL BE INSULATED WITH 1" THK. ARMAFLEX. 8 or larger 1/16
30.PLUMBING PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ IN CONJUNCTION
WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, FIRE SPRINKLER, STRUCTURAL AND CIVIL PLANS AND TABLE 704.1 OF THE FLORIDA PLUMBING CODE 2017
SHALL BE CONSIDERED AS ONE SET OF DOCUMENTS. PIPING MODIFICATIONS SUCH AS OFFSETS, BENDS,
TRANSITIONS, AND SIZES SHALL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL PLUMBING NOTES
SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
CHANGES IN PIPE SIZES AND ROUTING SHALL BE REQUIRED BY THE CONTRACTOR TO AVOID CONFLICTS
AND TO ADAPT TO EXISTING FIELD CONDITIONS PROVIDED THAT INSTALLATION MEETS ALL
APPLICABLE CODES. DRAWN TR/ST DATE: CHECKED
BY: BY:
31. SUPPLY TRAP PRIMER FOR ALL FLOOR DRAINS, FLOOR SINKS, HUB DRAINS, ETC. SHOWN ON PLANS. THIS DESIGN 06/25/2021
DRAWING
32.CONTRACTOR TO FIELD VERIFY ALL SUPPLY PRESSURE REQUIREMENTS AND LIMITATIONS. PROVIDE HAS BEEN
ISSUED ON CD
PRESSURE REDUCING VALVE IF REQUIRED. ISSUED FOR PERMIT ONLY 06-29-21 THE
NOT FOR PRICING OR CONSTRUCITON FOR THE
PURPosE BID - =Pp")"'
NOTED
Digitally signed by Bradly KAMM CONSULTING PROJECT#: 2021-0212
Brown PROJECT MANAGER: JOHN MAYR JOB IRLIE MM(vVu BIE Ro
Brad DN: e=US, st=Florida, I=Fort M M 1408 Orange Avenue
Fort ,Florida
Pierce, o=Kamm Consulting, Ph ne1erce 954 448 0 92 4950
jmayr@kammconsulting.com
OU=Princi al Exec.Vice OnsU n9
Certification of Authorization#8189
President, cn=Bradly Brown, PRINCIPAL 08-09-21
email=bbrown@kammeonsulti BradlyLBrown Florida License#58232 date Pool
ng.eom signed
BrownDate: 2021.08.09 12:59:45
-04'00'