Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GASPARILLA- MANUAL J(1)
L--r wrigni Projecty Summary Job: GARAGE LEFT Date: JUNE 24,2021 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: HUDSON 4 MODEL, SYNERGY BUILDERS 430 SE GASPARILLA AVENUE, PORT ST LUCIE, FL34983 Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18300 Btuh Structure 18001 Btuh Ducts 5677 Btuh Ducts 8137 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23978 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 24831 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4391 Btuh Ducts 2200 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 1833 183 Equipment latent load 6591 Btuh Volume (ft3) 17168 17168 Air changes/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 31422 Btuh Equiv.AVF (cfm) 109 57 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR40361-1 AHRI ref Coil TEM4AOC37S31++TDR AHRI ref 201763661 Efficiency 100 EFF Efficiency 12.2 EER, 14.5 SEER Heating input 10.0 kW Sensible cooling 24500 Btuh Heating output 34121 Btuh Latent cooling 10500 Btuh Temperature rise 27 °F Total cooling 35000 Btuh Actual air flow 1167 cfm Actual air flow 1167 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �•••,.)Oft—ord- wrigl 2021-Jun-24 14:21:32 Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 1 = ...ts\Wrightsoft HVAC\HUDSON 4-GASPARILLAAVE.rup Calc=MJ8 Front Door faces: NW IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: JUNE 24,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name Entire House M BATH 2 Exposed wall 166.9 ft 20.0 ft 3 Room height 9.4 ft 8.0 ft heat/cool 4 Room dimensions 6.0 x 14.0 ft 5 Room area 1833.0 ft2 84.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�j13A-4ocs 0.143 n 4.00 2.19 372 322 1290 705 48 48 192 105 2 glazing,clr low-e 0.550 n 15.40 13.49 41 0 628 550 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 9.95 9 0 76 90 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 572 542 2170 1186 0 0 0 0 11 2 glazing,clr low-e 0.300 a 8.40 29.48 30 0 252 885 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 160 125 499 273 0 0 0 0 I!-G� 2 glazing,clr low-e 0.300 s 8.40 9.95 15 30 126 149 0 0 0 0 D 11DO 0.390 s 10.92 10.34 20 20 223 211 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 392 362 1449 792 112 112 448 245 2 glazing,clr low-e 0.300 w 8.40 29.48 30 0 252 885 0 0 0 0 C 1613-30ad 0.032 0.90 1.60 1833 1833 1642 2933 84 84 75 134 F 22A-tph 1.358 38.02 0.00 1833 167 6347 0 84 20 760 0 6 c)AED excursion 0 -23 Envelope loss/gain 14954 8657 1476 461 12 a) Infiltration 3346 943 358 101 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 8400 300 Subtotal(lines 6 to 13) 18300 18001 1834 862 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18300 18001 1834 862 15 Duct loads 31% 45% 5677 8137 31% 45% 569 390 Total room load 23978 26138 2403 1252 Air required(cfm) 1167 1167 117 56 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Jun-2414:21:32 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 1 ...ts\Wrightsoft HVAC\HUDSON 4-GASPARILLAAVE.rup Calc=MJ8 Front Door faces: NW IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: JUNE 24,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name M WIC MASTER BEDROOM 2 Exposed wall 9.0 ft 29.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x 14.0 ft 15.0 x 14.0 ft 5 Room area 126.0 ft2 210.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�j13A-4ocs 0.143 n 4.00 2.19 72 72 288 158 120 111 444 243 2 glazing,clr low-e 0.550 n 15.40 13.49 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 9.95 0 0 0 0 9 0 76 90 13A-40 cs 0.143 e 4.00 2.19 0 0 0 0 112 97 388 212 11 2 glazing,clr low-e 0.300 a 8.40 29.48 0 0 0 0 15 0 126 442 LV�✓ 13A-40cs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 I!-G� 2 glazing,clr low-e 0.300 s 8.40 9.95 0 0 0 0 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 w 8.40 29.48 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 0.90 1.60 126 126 113 202 210 210 188 336 F 22A-tph 1.358 38.02 0.00 126 9 342 0 210 29 1103 0 6 c)AED excursion -11 -44 Envelope loss/gain 743 349 2325 1279 12 a) Infiltration 161 45 519 146 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 900 Subtotal(lines 6 to 13) 904 394 2844 2325 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 1 2 0 0 14 Subtotal 906 396 2844 2325 15 Duct loads 31% 45% 281 179 31% 45% 882 1051 Total room load 1187 576 3727 3376 Air required(cfm) 581261181 151 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Jun-2414:21:32 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 2 ...ts\Wrightsoft HVAC\HUDSON 4-GASPARILLAAVE.rup Calc=MJ8 Front Door faces: NW IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: JUNE 24,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 3 CLST 3 2 Exposed wall 11.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 149.0 ft 2.0 x 8.0 ft 5 Room area 149.0 ft2 16.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 I;�C 2 glazing,clr low-e 0.550 n 15.40 13.49 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 9.95 0 0 0 0 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.300 a 8.40 29.48 0 0 0 0 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 I!-G� 2 glazing,clr low-e 0.300 s 8.40 9.95 0 0 0 0 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 88 73 292 160 0 0 0 0 2 glazing,clr low-e 0.300 w 8.40 29.48 15 0 126 442 0 0 0 0 C 16B-30ad 0.032 0.90 1.60 149 149 134 238 16 16 14 26 F 22A-tph 1.358 38.02 0.00 149 11 418 0 16 0 0 0 6 c)AED excursion 183 -1 Envelope loss/gain 970 1023 14 25 12 a) Infiltration 197 55 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 0 Subtotal(lines 6 to 13) 1167 1578 14 25 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 12 20 -14 -25 14 Subtotal 1178 1599 0 0 15 Duct loads 31% 45% 366 723 31% 45% 0 0 Total room load 1544 2321 0 0 Air required(cfm) 751 10410 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Jun-2414:21:32 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 3 ...ts\Wrightsoft HVAC\HUDSON 4-GASPARILLAAVE.rup Calc=MJ8 Front Door faces: NW IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: JUNE 24,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name KITCHEN/DINING BATH 2 2 Exposed wall 26.0 ft 6.0 ft 3 Room height 12.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 376.0 ft 12.0 x 6.0 ft 5 Room area 376.0 ft2 72.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�j13A-4ocs 0.143 n 4.00 2.19 132 91 365 200 0 0 0 0 2 glazing,clr low-e 0.550 n 15.40 13.49 41 0 628 550 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 9.95 0 0 0 0 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 180 165 661 361 0 0 0 0 11 2 glazing,clr low-e 0.300 a 8.40 29.48 15 0 126 442 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 I!-G� 2 glazing,clr low-e 0.300 s 8.40 9.95 0 0 0 0 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 48 48 192 105 2 glazing,clr low-e 0.300 w 8.40 29.48 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 0.90 1.60 376 376 337 602 72 72 65 115 F 22A-tph 1.358 38.02 0.00 376 26 989 0 72 6 228 0 6 c)AED excursion -151 -20 Envelope loss/gain 3106 2004 485 201 12 a) Infiltration 698 197 107 30 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 3400 500 Subtotal(lines 6 to 13) 3803 5601 592 731 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 16 27 9 15 14 Subtotal 3819 5628 601 746 15 Duct loads 31% 45% 1185 2544 31% 45% 186 337 Total room load 5004 8172 787 1083 Air required(cfm) 2441 3651 38 48 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Jun-2414:21:32 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 4 ...ts\Wrightsoft HVAC\HUDSON 4-GASPARILLAAVE.rup Calc=MJ8 Front Door faces: NW IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: JUNE 24,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 HALL 2 Exposed wall 12.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 12.0 x 12.0 ft 1.0 x 39.0 ft 5 Room area 144.0 ft2 39.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 I;�C 2 glazing,clr low-e 0.550 n 15.40 13.49 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 9.95 0 0 0 0 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.300 a 8.40 29.48 0 0 0 0 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 I!-G� 2 glazing,clr low-e 0.300 s 8.40 9.95 0 0 0 0 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 96 81 324 177 0 0 0 0 2 glazing,clr low-e 0.300 w 8.40 29.48 15 0 126 442 0 0 0 0 C 16B-30ad 0.032 0.90 1.60 144 144 129 230 39 39 35 62 F 22A-tph 1.358 38.02 0.00 144 12 456 0 39 0 0 0 6 c)AED excursion 182 -2 Envelope loss/gain 1036 1032 35 61 12 a) Infiltration 215 61 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 0 Subtotal(lines 6 to 13) 1250 1593 35 61 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 13 23 -35 -61 14 Subtotal 1263 1615 0 0 15 Duct loads 31% 45% 392 730 31% 45% 0 0 Total room load 1655 2345 0 0 Air required(cfm) 81 105 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Jun-2414:21:32 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 5 ...ts\Wrightsoft HVAC\HUDSON 4-GASPARILLAAVE.rup Calc=MJ8 Front Door faces: NW IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: JUNE 24,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name CLST 2 LAUNDRY 2 Exposed wall 0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 2.0 x 8.0 ft 7.0 x 8.0 ft 5 Room area 16.0 ft2 56.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 I;�C 2 glazing,clr low-e 0.550 n 15.40 13.49 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 9.95 0 0 0 0 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 11 2 glazing,clr low-e 0.300 a 8.40 29.48 0 0 0 0 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 I!-G� 2 glazing,clr low-e 0.300 s 8.40 9.95 0 0 0 0 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 w 8.40 29.48 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 0.90 1.60 16 16 14 26 56 56 50 90 F 22A-tph 1.358 38.02 0.00 16 0 0 0 56 0 0 0 6 c)AED excursion -1 -18 Envelope loss/gain 14 25 50 72 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 600 Subtotal(lines 6 to 13) 14 25 50 672 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -14 -25 200 130 14 Subtotal 0 0 250 801 15 Duct loads 31% 45% 0 0 31% 45% 78 362 Total room load 0 0 328 1163 Air required(cfm) 01 01 16 52 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Jun-2414:21:32 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 6 ...ts\Wrightsoft HVAC\HUDSON 4-GASPARILLAAVE.rup Calc=MJ8 Front Door faces: NW IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: JUNE 24,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name AHU CLST GREAT ROOM 2 Exposed wall 0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 12.0 ft heat/cool 4 Room dimensions 3.0 x 3.0 ft 1.0 x 250.0 ft 5 Room area 9.0 ft2 250.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 I;�C 2 glazing,clr low-e 0.550 n 15.40 13.49 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 9.95 0 0 0 0 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 0 0 0 0 168 168 673 368 11 2 glazing,clr low-e 0.300 a 8.40 29.48 0 0 0 0 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 I!-G� 2 glazing,clr low-e 0.300 s 8.40 9.95 0 0 0 0 0 0 0 0 D 11DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 w 8.40 29.48 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 0.90 1.60 9 9 8 14 250 250 224 400 F 22A-tph 1.358 38.02 0.00 9 0 0 0 250 14 532 0 6 c)AED excursion 0 -54 Envelope loss/gain 8 14 1429 713 12 a) Infiltration 0 0 376 106 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1200 Subtotal(lines 6 to 13) 8 14 1805 2019 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -8 -14 544 302 14 Subtotal 0 0 2348 2321 15 Duct loads 31% 45% 0 0 31% 45% 729 1049 Total room load T0 0 3077 3370 Air required(cfm) 0 0 150 150 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Jun-2414:21:32 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 7 ...ts\Wrightsoft HVAC\HUDSON 4-GASPARILLAAVE.rup Calc=MJ8 Front Door faces: NW IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: JUNE 24,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name FOYER CLST 4 2 Exposed wall 7.0 ft 2.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 112.0 ft 1.0 x 16.0 ft 5 Room area 112.0 ft2 16.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�/ 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 I;�C 2 glazing,clr low-e 0.550 n 15.40 13.49 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 9.95 0 0 0 0 0 0 0 0 13A-40 cs 0.143 e 4.00 2.19 0 0 0 0 16 16 64 35 11 2 glazing,clr low-e 0.300 a 8.40 29.48 0 0 0 0 0 0 0 0 LV�✓ 13A-40cs 0.143 s 4.00 2.19 56 36 143 78 0 0 0 0 I!-G� 2 glazing,clr low-e 0.300 s 8.40 9.95 0 0 0 0 0 0 0 0 D 11DO 0.390 s 10.92 10.34 20 20 223 211 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 w 8.40 29.48 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 0.90 1.60 112 112 100 179 16 16 14 26 F 22A-tph 1.358 38.02 0.00 112 7 266 0 16 2 76 0 6 c)AED excursion -13 -2 Envelope loss/gain 732 455 154 59 12 a) Infiltration 125 35 36 10 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 857 490 190 69 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -857 -490 -190 -69 14 Subtotal 0 0 0 0 15 Duct loads 31% 45% 0 0 31% 45% 0 0 Total room load 0 0 0 0 Air required(cfm) 01 01 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Jun-2414:21:32 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 8 ...ts\Wrightsoft HVAC\HUDSON 4-GASPARILLAAVE.rup Calc=MJ8 Front Door faces: NW IL w„y" Right-J®Worksheet Job: GARAGE LEFT Entire House Date: JUNE 24,2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 4/DEN 2 Exposed wall 30.9 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 1.0 x 158.0 ft 5 Room area 158.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6V�j13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 2 glazing,clr low-e 0.550 n 15.40 13.49 0 0 0 0 2 glazing,clr low-e 0.300 n 8.40 9.95 0 0 0 0 V�✓ 13A-4ocs 0.143 e 4.00 2.19 96 96 384 210 11 l C 2 glazing,clr low-e 0.300 e 8.40 29.48 0 0 0 0 13A-4ocs 0.143 s 4.00 2.19 104 89 356 195 2 glazing,clr low-e 0.300 s 8.40 9.95 15 15 126 149 D 11DO 0.390 s 10.92 10.34 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 48 48 192 105 2 glazing,clr low-e 0.300 w 8.40 29.48 0 0 0 0 C 1613-30ad 0.032 0.90 1.60 158 158 142 253 F 221%-tph 1.358 38.02 0.00 158 31 1176 0 6 c)AED excursion -25 Envelope loss/gain 2376 886 12 a) Infiltration 555 156 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 500 Subtotal(lines 6 to 13) 2931 1543 Less external load 0 0 Less transfer 0 0 Redistribution 325 165 14 Subtotal 3256 1708 15 Duct loads 31% 45% 1010 772 Total room load 4266 2480 Air required(cfm) 208 111 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - 34k -r"- wrigl 2021-Jun-2414:21:32 Right-Suite®Universal 2021 21.0.02 RSU08101 Page 9 ...ts\Wrightsoft HVAC\HUDSON 4-GASPARILLAAVE.rup Calc=MJ8 Front Door faces: NW L-7 wrignI Duct System Summary Job: GARAGE LEFT Date: JUNE 24,2021 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: HUDSON 4 MODEL, SYNERGY BUILDERS 430 SE GASPARILLA AVENUE, PORT ST LUCIE, FL34983 Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply/ return available pressure 0.500/ 0.500 in H2O 0.500/0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 1167 cfm 1167 cfm Total effective length (TEL) 142 ft Supply Branch DetailTable Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH 2 c 1083 38 48 1.000 6.0 Ox 0 VIFx 5.0 95.0 BEDROOM 2 c 2345 81 105 1.000 7.0 Ox0 VIFx 10.0 95.0 BEDROOM 3 c 2321 75 104 1.000 7.0 Ox0 VIFx 22.0 115.0 st1 BEDROOM 4/DEN h 4266 208 111 1.000 7.0 Ox0 VIFx 23.4 95.0 GREAT ROOM c 3370 150 150 1.000 8.0 Ox 0 VIFx 25.5 115.0 st2 KITCHEN/DINING c 2724 81 122 1.000 7.0 Ox0 VIFx 25.5 115.0 st2 KITCHEN/DINING-A c 2724 81 122 1.000 7.0 Ox0 VIFx 20.1 115.0 st2 KITCHEN/DINING-B c 2724 81 122 1.000 7.0 Ox0 VIFx 20.4 115.0 st1 LAUNDRY c 1163 16 52 1.000 6.0 Ox0 VIFx 4.5 95.0 M BATH h 2403 117 56 1.000 6.0 Ox 0 VIFx 26.8 115.0 st 1 M WIC h 1187 58 26 1.000 5.0 Ox 0 VIFx 23.3 115.0 st 1 MASTER BEDROOM h 3727 181 151 1.000 8.0 Ox0 VIFx 23.0 115.0 st1 • • Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 312 394 1.000 722 10.0 0 x 0 VinlFlx st1 Peak AVF 512 458 1.000 652 12.0 0 x 0 VinlFlx - --eft- 1•F wrigl 2021-Jun-24 14:21:37 Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 1 �L u ...ts\Wrightsoft HVAC\HUDSON 4-GASPARILLAAVE.rup Calc=MJ8 Front Door faces: NW TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox0 1167 1167 0 0 0 0 Ox 0 VIFx — --311ft°S-'1•F wrigl 2021-Jun-24 14:21:37 Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 2 �L u ...ts\Wrightsoft HVAC\HUDSON 4-GASPARILLAAVE.rup Calc=MJ8 Front Door faces: NW