HomeMy WebLinkAboutRevised Energy Calcs(1)FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: HUDSON 4 MODEL
Builder Name: SYNERGY BUILDERS
Street: 430 SE GASPARILLA AVENUE
Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE , FL, 34983
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, MELBOURNE_REGIONAL_AP
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Types(1728.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1496.00 ft2
b. Frame - Wood, Adjacent
R=13.0 232.00 ft
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
11. Ceiling Types (1833.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1833.00 ft2
6. Conditioned floor area above grade (ft2) 1833
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows (124.0 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: AHU CLST
R
6 140
a. U-Factor: Sgl, U=0.30 124.00 ft2
SHGC: SHGC=0.26
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
35.0 SEER:14.50
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 4.105 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.260
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1833.0 sqft.) Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation R=0.0 1833.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
None
Glass/Floor Area: 0.068 Total Proposed Modified Loads: 50.29
PASS
Total Baseline Loads: 55.01
I hereby certify that the plans and specifications covered by
Review of the plans and�HE7.g7.
0, _ fi
this calculation are in compliance with the Florida Energy
specifications covered by this
`,•'',�`
Code.
PREPAREQBiY�
calculation indicates compliance
with the Florida Energy Code.''
Before construction is completed
�,J'°° �'
DATE:
this building will be inspected for
`�
compliance with Section 553.908
*
I herebycertify that this building, as designed, is in compliance
Y 9 9 p
Florida Statutes.
with the Florida Energy Code.
WE
OWNER/AGENT: Y--L
BUILDING OFFICIAL:
DATE: -f U -Z-t
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
9/10/2021 10:01 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPURT
PROJECT
Title:
HUDSON 4 MODEL
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1833
Lot #
Owner Name:
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
SYNERGY BUILDERS
Rotate Angle:
0
Street:
430 SE GASPARILLA A
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
PORT ST LUCIE,
Family Type:
Detached
FL, 34983
New/Existing:
New (From Plans)
Comment:
GARAGE LEFT
CLIMATE
Design Temp
Int Design Temp
Heating
Design
Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, MELBOURNE_REGIO FL_MELBOURNE_REGIO
45
90
70
75
369
69
Medium
BLOCKS
Number
Name
Area
Volume
1
Entire House
1833
17168
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
M BATH
84
672
No
0
1
Yes
Yes
Yes
2
M WIC
126
1008
No
0
1
Yes
Yes
Yes
3
MASTER BEDROO
210
1680
No
0
1
1
Yes
Yes
Yes
4
BEDROOM 3
149
1192
No
0
1
1
Yes
Yes
Yes
5
CLST 3
16
128
No
0
1
No
Yes
Yes
6
KITCHEN/DINING
376
4512
Yes
0
1
Yes
Yes
Yes
7
BATH 2
72
576
No
0
1
Yes
Yes
Yes
8
BEDROOM 2
144
1152
No
0
1
1
Yes
Yes
Yes
9
HALL
39
312
No
0
1
No
Yes
Yes
10
CLST 2
16
128
No
0
1
No
Yes
Yes
11
LAUNDRY
56
448
No
0
1
No
Yes
Yes
12
AHU CLST
9
72
No
0
1
No
Yes
Yes
13
GREAT ROOM
250
3000
No
0
1
Yes
Yes
Yes
14
FOYER
112
896
No
0
1
Yes
Yes
Yes
15
CLST 4
16
128
No
0
1
Yes
Yes
Yes
16
BEDROOM 4/DEN
158
1264
No
0
1
1
Yes
Yes
Yes
FLOORS
#
Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation M BATH 20 ft
0
84 ft2
----
1 0
0
2 Slab -On -Grade Edge Insulation M W IC 9 ft
0
126 ft2
----
1 0
0
9/10/2021 10:01 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
3 Slab -On -Grade Edge Insulation
MASTER BEDRO
29 ft
0
210 ft2
----
1
0
0
4 Slab -On -Grade Edge Insulation
BEDROOM 3
11 ft
0
149 ft2
----
1
0
0
5 Slab -On -Grade Edge Insulation
CLST 3
1 ft
0
16 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulation
KITCHEN/DININ
26 ft
0
376 ft2
----
1
0
0
7 Slab -On -Grade Edge Insulation
BATH 2
6 ft
0
72 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulation
BEDROOM 2
12 ft
0
144 ft2
----
1
0
0
9 Slab -On -Grade Edge Insulation
HALL
1 ft
0
39 ft2
----
1
0
0
10SIab-On-Grade Edge Insulation
CLST 2
1 ft
0
16 ft2
----
1
0
0
11SIab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
56 ft2
----
1
0
0
12SIab-On-Grade Edge Insulation
AHU CLST
1 ft
0
9 ft2
----
1
0
0
13SIab-On-Grade Edge Insulation
GREAT ROOM
14 ft
0
250 ft2
----
1
0
0
14SIab-On-Grade Edge Insulation
FOYER
7 ft
0
112 ft2
----
1
0
0
15SIab-On-Grade Edge Insulation
CLST 4
2 ft
0
16 ft2
----
1
0
0
16SIab-On-Grade Edge Insulation
BEDROOM 4/DE 30.9 ft
0
158 ft2
----
1
0
0
ROOF
Roof
Gable
Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Composition shingles 2049 ft2
0 ft2
Medium
N
0.2 No 0.9
No
0
26.57
ATTIC
V # Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Vented
150
1833 ft2
N N
9/10/2021 10:01 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented)
M BATH
30
Blown
84 ft2
0.1
Wood
2
Under Attic (Vented)
M W IC
30
Blown
126 ft2
0.1
Wood
3
Under Attic (Vented)
MASTER BEDRO
30
Blown
210 ft2
0.1
Wood
4
Under Attic (Vented)
BEDROOM 3
30
Blown
149 ft2
0.1
Wood
5
Under Attic (Vented)
CLST 3
30
Blown
16 ft2
0.1
Wood
6
Under Attic (Vented)
KITCHEN/DININ
30
Blown
376 ft2
0.1
Wood
7
Under Attic (Vented)
BATH 2
30
Blown
72 ft2
0.1
Wood
8
Under Attic (Vented)
BEDROOM 2
30
Blown
144 ft2
0.1
Wood
9
Under Attic (Vented)
HALL
30
Blown
39 ft2
0.1
Wood
10
Under Attic (Vented)
CLST 2
30
Blown
16 ft2
0.1
Wood
11
Under Attic (Vented)
LAUNDRY
30
Blown
56 ft2
0.1
Wood
12
Under Attic (Vented)
AHU CLST
30
Blown
9 ft2
0.1
Wood
13
Under Attic (Vented)
GREAT ROOM
30
Blown
250 ft2
0.1
Wood
14
Under Attic (Vented)
FOYER
30
Blown
112 ft2
0.1
Wood
15
Under Attic (Vented)
CLST 4
30
Blown
16 ft2
0.1
Wood
16
Under Attic (Vented)
BEDROOM 4/DE
30
Blown
158 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Belowo
Space
1
SE
Exterior Concrete Block
- Int Insul M BATH
4.1
6
0 8
0
48.0 ft2
0
0
0.2
0
2
NE
Exterior Concrete Block
- Int Insul M BATH
4.1
14
0 8
0
112.0 ft2
0
0
0.2
0
3
SE
Exterior Concrete Block
- Int Insul M W IC
4.1
9
0 8
0
72.0 ft2
0
0
0.2
0
4
SE
Exterior Concrete Block
- Int InsuMASTER BE
4.1
15
0 8
0
120.0 ft2
0
0
0.2
0
5
SW
Exterior Concrete Block
- Int InsuMASTER BE
4.1
14
0 8
0
112.0 ft2
0
0
0.2
0
6
NE
Exterior Concrete Block
- Int InsuBEDROOM 3
4.1
11
0 8
0
88.0 ft2
0
0
0.2
0
7
SE
Exterior Concrete Block
- Int InsuKITCHEN/DI
4.1
11
0 12
0
132.0 ft2
0
0
0.2
0
8
SW
Exterior Concrete Block
- Int InsuKITCHEN/DI
4.1
15
0 12
0
180.0 ft2
0
0
0.2
0
9
NE
Exterior Concrete Block
- Int Insul BATH 2
4.1
6
0 8
0
48.0 ft2
0
0
0.2
0
10
NE
Exterior Concrete Block
- Int InsuBEDROOM 2
4.1
12
0 8
0
96.0 ft2
0
0
0.2
0
11
NW
Garage Frame - Wood
BEDROOM 2
13
12
0 8
0
96.0 ft2
0
0.1
0.2
0
12
NW
Garage Frame - Wood
CLST 2
13
2
0 8
0
16.0 ft2
0
0.1
0.2
0
13
NW
Garage Frame - Wood
LAUNDRY
13
7
0 8
0
56.0 ft2
0
0.1
0.2
0
14
SW
Exterior Concrete Block
- Int InsuGREAT ROO
4.1
14
0 12
0
168.0 ft2
0
0
0.2
0
15
NW
Exterior Concrete Block
- Int Insul FOYER
4.1
7
0 8
0
56.0 ft2
0
0
0.2
0
16
NE
Garage Frame - Wood
FOYER
13
8
0 8
0
64.0 ft2
0
0.1
0.2
0
17
SW
Exterior Concrete Block
- Int Insul CLST 4
4.1
2
0 8
0
16.0 ft2
0
0
0.2
0
18
NE
Exterior Concrete Block
- Int InsLiBEDROOM 4/
4.1
6
0 8
0
48.0 ft2
0
0
0.2
0
19
NW
Exterior Concrete Block
- Int InsLiBEDROOM 4/
4.1
13
0 8
0
104.0 ft2
0
0
0.2
0
20
SW
Exterior Concrete Block
- Int InsLIBEDROOM 4/
4.1
12
0 8
0
96.0 ft2
0
0
0.2
0
9/10/2021 10:01 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1
2
3
4
5
6
7
SE 4 Metal Low-E Single
SW 5 Metal Low-E Single
NE 6 Metal Low-E Single
SE 7 Metal Low-E Single
SW 8 Metal Low-E Single
NE 10 Metal Low-E Single
NW 19 Metal Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.3 0.26 N 9.0 ftz 1 ft 0 in 1 ft 4 in
0.3 0.26 N 15.0 ftz 8 ft 0 in 1 ft 4 in
0.3 0.26 N 15.0 ftz 1 ft 0 in 1 ft 4 in
0.3 0.26 N 40.0 ftz 8 ft 0 in 1 ft 4 in
0.3 0.26 N 15.0 ftz 1 ft 0 in 1 ft 4 in
0.3 0.26 N 15.0 ftz 1 ft 0 in 1 ft 4 in
0.3 0.26 N 15.0 ftz 1 ft 0 in 1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
441 ft2 441 ftz
21 ft 8 ft
13
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000297
1430.7 78.49 147.36 .1044
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1 27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 14.5 35 kBtu/hr 1050 cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric None
Garage
0.92 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ftz
DUCTS
V #
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
ON RLF
HVAC #
Heat Cool
1
Attic 6 140 ftz
Attic
14 ftz Default Leakage AHU CLST (Default) c(Default) c
1 1
9/10/2021 10:01 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan
HeatinJan
Feb
�Xj Feb
]Mar
Mar
Apr
f Apr
f
May
May
Jun
Jun
rl
Jul
Jul
�xl
X Aug
f Aug
Se
4 Sep
Oct
Oct
Nov
Nov
Dec
X Dec
Venting Jan
[[ ]] Feb
lX]
[X] Mar
[X] Apr
[
May
Jun
Jul
[ Aug
[ Sep
[ Oct [X
Nov
[ Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (W D)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (W EH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (W D)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (W EH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ftz
0 ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ftz
ft
0.3
FOYER/LIVING
Default(8 Ibs/sq.ft.
ftz
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ftz
ft
0.3
M CLST 1
Default(8 Ibs/sq.ft.
ftz
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ftz
ft
0.3
M CLST 2
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ftz
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ftz
ft
0.3
HALL
Default(8lbs/s .ft.
ftz
ft
0.3
LAUNDRY
9/10/2021 10:01 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: HUDSON 4 MODEL Builder Name: SYNERGY BUILDERS
Street: 430 SE GASPARILLA AVENUE Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE , FL, 34983 Permit Number:
Y
U
Owner: Jurisdiction: ST LUCIE COUNTY
=
Design Location: FL, MELBOURNE_REGIONAL_AP
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub -floor, wall covering or ceiling
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilincis.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
9/10/2021 10:02 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 91
The lower the EnergyPerformance Index, the more efficient the home.
430 SE GASPARILLA AVENUE, PORT ST LUCIE, FL, 34983
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1496.00 ft2
b. Frame - Wood, Adjacent
R=13.0 232.00 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
4
d. N/A
R= ft2
11. Ceiling Type and insulation level
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 1833.00 ft2
6. Conditioned floor area (ft2)
1833
b. N/A
R= ft2
7. Windows" Description
Area
c. N/A
R= ft2
a. U-Factor: Sgl, U=0.30
124.00 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Attic, AH: AHU CLST
6 140
SHGC: SHGC=0.26
b. U-Factor: N/A
ft2
SHGC:
13. Cooling systems
kBtu/hr Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
35.0 SEER:14.50
SHGC:
d. U-Factor: N/A
ft2
14. Heating systems
kBtu/hr Efficiency
SHGC:
a. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average Overhang Depth:
4.105 ft.
Area Weighted Average SHGC:
0.260
8. Skylights Description
Area
15. Hot water systems
Cap: 40 gallons
a. U-Factor(AVG): N/A
ft2
a. Electric
EF: 0.92
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation Area
None
a. Slab -On -Grade Edge Insulation
R=0.0 1833.00 ft2
Credits (Performance method)
None
b. N/A
R= ft2
c. N/A
R= ft2
I certify that this home has complied
with the Florida Energy
Efficiency Code for Building
Construction through the above energy saving features which
will be installed (or exceeded)
l�
in this home before final inspection.
Otherwise, a new EPL Display Card will be completed
C DD T
based on installed Code compliant features.
Builder Signature:
Date:
SHE S7q
Address of New Home:
City/FL Zip:ti'
04
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/10/2021 10:02 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1