HomeMy WebLinkAboutSurveyZ
O
rn
119 w
VACANT
W
O
O
O
PROPOSED
SANITARY
��— O
aON f tLK
FLOOD ZONE AE
WATER MANAGEMENT TRACT 3
R=4 5: m ,
A=WV23" °
L=70.66'
11"'00'
PROPOSED
COVERED
LANAI,
118 11.00' '
V-
VACANT
PROPOSED
MODEL 4EBB/C
o
F.F.E.=18.63
i�
GARAGE F.F.E.=18.13
CO
EXISTING BUILDING
a
LO
PAD EL=18.70
4.
4.67'-
PROPOSED
4' CONC.
WALK
3S 21.33'
F!!= o
PROPOSED
CCNCRETE
DRIVEWAY
16.00'
011
FLOOD ZONE
RI
r 1 %yr v.j�
COVERED N
ENTRY r-
�4.67' N
14.00' 7.73'
PROPOSED
WATER
— SERVICE
-`may-� "`a. ----
'� I
I
is t o
VVI ! O
RVW
117
VACANT
' 'ss POTOMAC DRIVE ass PRIVAKROAD50.0R/W
— r=320.00 R=320.00' R=32
R
A=8'31'25" 0.00� —
'i p`67'3809 — A=37'3345"
BENCHMARK
% CpNCi�E>E 'WALK
PRbPOSED _ _ RIM EL,=16.53- — —
MIN.
LOT 118 AREA SUMMARY IN SQUARE FEET FRONT
SOD: 5127f SIDES.
DRIVEWAY/WALKWAY: 699f CNR S'
REAR_
ZING, _
LEGAL DESCRIPTION
Being all of Lot 118, according to the plat of CREEKSIDE PLAT NO. 4, as
recorded in Plat Book 85, Page 5, Public Records of St. Lucie County, Florida.
Containing 0.182 acres, more or less.
GRAPHIC SCALE
zo o ,o zo
REQ.
( IN FIZT
1 bwh - 20 !t
PROPERTY ADDRESS `j y ;) '':' :; PF:; il' . :S!
9512 POTOMAC DRIVE FORT PIERCE, FLORIDA 5 �w
GENERAL NOTES ! ' C.3 �:yl 'j'';✓ y�
1. The last date of field work was 06-14-19
2. Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of
the signing party or parties.
3. Reproductions of this map are not valid without the original signature and raised seal of a Florida Licensed Surveyor and Mapper.
4. Lands shown hereon were not abstracted by this office for rights —of —way, easements of record, ownership, abandonment's, deed
restrictions, or Murphy Act Deeds. This information should be obtained through appropriate title verification.
5. All above ground fixed improvements, if any, have been located and shown hereon.
6. Underground foundations and improvements were not located as part of this survey.
7. Flood Note: By graphic plotting only, this property is in Zone X and AE 16.9, according to the Flood Insurance Rate Map, Community
Panel No. 12111CO170 J, effective date February 16, -2012. The exact designation can only be determined by an elevation certificate. N
additional search of the public records has been preformed. There may be additional map Amendments affecting this property.
8. The Flood Zone lines shown hereon have been established by the Published FEMA Panel and the use of existing field elevation data.
9. The bearings shown hereon are based on Plat information and are referenced to the Easterly line of Lot 118 which bears South
07'25'01" West and all bearings are relative thereto.
,10. No easements are shown hereon other than those depicted -on the plat. No search of the public records has been performed to find
additional easements that may exist.
11. Elevations .shown hereon are based on the North American Vertical Datum (N.A.V.D.) 1988.
`12. The building setbacks shown hereon, although based on the best available information, are not certified to and must be verified prior
to design or construction.
,13. All improvements relating to this plat are either proposed or under construction.
LEGEND &_ ABBREVIATIONS
BB DENOTES BEARING BASE O.S.T. DENOTES OPEN SPACE TRACT
CBS DENOTES CONCRETE BLOCK STRUCTURE P.S.M. DENOTES PROFESSIONAL SURVEYOR & MAPPER
C DENOTES CHORD BEARING & DISTANCE P.L.S. DENOTES PROFESSIONAL LAND SURVEYOR
(i DENOTES CENTER LINE R DENOTES RADIUS
D.E. DENOTES DRAINAGE EASEMENT
F.F.E. DENOTES FINISH FLOOR ELEVATION R/W DENOTES RIGHT OF WAY
FND DENOTES FOUND U.E. DENOTES UTILITY EASEMENT
IR/C DENOTES IRON ROD AND CAP W.M.T. DENOTES WATER MANAGEMENT TRACT
L.B. DENOTES LICENSED BUSINESS DENOTES INCLUDED ANGLE
L DENOTES ARC LENGTH '�L DENOTES DRAINAGE FLOW
NN/DD DENOTES NAIL AND DISK �5 DENOTES PROPOSED ELEVATION
? / ij` .. 1-712—� >Y� DENOTES FIRE HYDRANT
T,HOMAS P. KIERNAN
Professional Surveyor & Mapper
Florida Certificate No. 6199
Boundary, Topographic &
Site Plan Survey -Lot 118
-For: D. R. HORTON
DATE
File:15-141.004.118
CULPEPPER &
2-30-2020
FB: N
FB: N/A
® TERPENING INC
SCALE 1 "=20'
2980 SOUTH 25th STREET • FORT PIERCE. FLORIDA 34981
DRAWN BY: RMR
PHONE 772-464-3537 • FAX 772-464-9497 • www.ct-eng.com
FIELD: PK
STATE OF FLORIDA BOARD OF PROFESSIONAL
ENGINEERS AUTHORIZATION NO.4286