HomeMy WebLinkAbout2012-0722 ProdRevAff&EvalReptsBuilding Permit # 2012-0722 Planning & Development Services Department Building & Regulations Division Product Review Affidavit Owners Name Mark Walpert Applicant: Mark Walpert Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass Type Method of Attachment Windows +47.1 -57.5 +80 -80 Comfort Line 2100 Awning 15974.2 R3 Impact Direct to frame per instr 15974.2 Mullions see attached window table for details Fixed Glass +43.8 -47.8 +80 -80 Comfort Line 2100 Picture 15973.3 R4 Impact Direct frame per instr 15973.3 Block Glass Skylights Sliding Glass Doors +43.4 -47.4 +50 -50 Comfort Line 5000 Futura 16112.1,.2 R2 Impact Direct to frame per instr 16112.1,.2 Swing Type Doors +45.4 -49.4 +50 -50 Jeld-Wen Smooth Pro 16674.1,2,3,4 R16 Impact Direct to frame per instr D015694,5,6,7.2 French Doors see attached door table for details Garage Doors +38.5 -42.2 +60 -60 Alpine Over. Redi-Storm 14017.1 R1 approved in permit 1506-0284 1/5/16 Hurricane Protection +40.0 -48.9 +54 -54 STO EIFS StoTherm CI 20110.1 R3 XPS adhered to sub, reinforced finish per S118G Roof Ventilation FLAT +19.1 -87.0 -502.5 Sika Corp Sikalastic RoofPro 17440.1 R4 C-4 polyurethane RoofPro TC System inst 14001.4 Roofing Material PITCH +19.1 -87.0 -127.5 GAF Everguard TPO 5293.1 R46 S-256,278,or307 adhered to deck board over 2" xps Revised 07/22/2014 I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: Mark Walpert Design Prof: see attached reports Cert. No. Mark Wa I pert Digitally signed by Mark Walpert Signature' Date: 2021.07.10 16:29:11-04'00' Date: 7/8/2 seal WINDOW TABLE Walpert Res. 5050 N A I A Hutchinson Is FL 06/09/21 KEY Loc'n - Direction CL 2100 Awning Frame w"x h" Rough Open " Hgt Flr" Pressure Req psi Area -sqft Press Rtg psi FL Ap G2 Hex -NW 31 1/4 x 39 1/2 31 3/4 x 40 44 +47.1 -51.1 8.82 +80 -80 15974.2 G3 CWStor-W 54 3/4 x 39 1/2 55 1/4 x 40 48 +46.1 -50.0 13.35 +80 -80 G6 Util-W 39 x 39 1/2 39 1/2 x 40 44 +47.1 -51.1 10.97 +80 -80 G7 GarE-S 27 1/8 x 39 1/2 27 5/8 x 40 62 +47.1 -51.1 7.67 +80 -80 G8 GarW-S 27 1/8 x 39 1/2 27 5/8 x 40 62 +47.1 -51.1 7.67 +80 -80 G11 Gar- N 27 1/8 x 39 1/2 27 5/8 x 40 61 +47.1 -51.1 7.67 +80 -80 G14 NStor -N 52 1/2 x 39 1/2 53 x 40 44 +47.1 -51.1 14.72 +80 -80 G17 NStor -E 59 1/2 x 39 1/2 60 x 40 44 +45.0 -49.0 16.67 +80 -80 G19 NStor -E 59 1/2 x 39 1/2 60 x 40 44 +45.0 -49.0 16.67 +80 -80 G23 SEStor -E 23 1/2 x 39 1/2 24 x 40 44 +42.1 -51.1 6.67 +80 -80 G25 Equip -S 59 1/2 x 31 1/2 60 x 32 52 +46.2 -50.2 13.33 +80 -80 G26 SEStor -S 59 1/2 x 31 1/2 60 x 32 52 +46.2 -50.2 13.33 +80 -80 G27 SEStor -S 51 1/2 x 31 1/2 52 x 32 52 +46.7 -50.7 11.55 +80 -80 F1 MBt-S 35 1/2 x 39 1/2 36 x 40 40 +47.1 -51.1 10 +80 -80 F2 MBt-N 35 1/2 x 39 1/2 36 x 40 40 +47.1 -51.1 10 +80 -80 F3 Stdy-W 55 1/2 x 39 1/2 56 x 40 40 +45.7 -49.7 15.56 +80 -80 F4 Lndg-W 55 1/2 x 39 1/2 56 x 40 40 +45.7 -49.7 15.56 +80 -80 F5 DR-W 55 1/2 x 39 1/2 56 x 40 40 +45.7 -49.7 15.56 +80 -80 F6 Bt2-S 31 1/2 x 39 1/2 32 x 40 40 +47.1 -51.1 8.89 +80 -80 F7 Br2-W 55 1/2 x 39 1/2 56 x 40 40 +45.7 -49.7 15.56 +80 -80 F15 K -E 59 1/2 x 39 1/2 60 x 40 44 +44.5 -48.5 16.67 +80 -80 F23 MBr-S 39 1/2 x 39 1/2 40 x 40 40 +47.1 -63.1 11.11 +80 -80 F24 MBr-S 55 1/2 x 39 1/2 56 x 40 40 +45.7 -49.7 15.56 +80 -80 LI L -W 59 1/2 x 39 1/2 60 x 40 40 +44.3 -57.5 16.67 +80 -80 L2 L -N 59 1/2 x 39 1/2 60 x 40 40 +45.0 -49.0 16.67 +80 -80 U-.27 (R-3.7), CR-57, SHGC-.18, LSG-2.11, Vis Light Trans-38%, Air Infiltration-0.007scfm/ft2@1.57psf KEY Loc'n - Direction CL 2100 Fixed Frame w"x h" Rough Open " Hgt FIr" Pressure Req psi Area -sqft Press Rtg psi FL Ap F17a W LR- E 71 1/2 x 71 1/2 72 x 72 120 +43.8 -47.8 36 +80 -80 15973.3 U-.25 (R-4.0), CR-58, SHGC-.18, LSG-2.11, Vis Light Trans-38%, Air Infiltration-0.005scfin/ft2@6.24psf White frames and accessories Impact requirement Large Missile level D for Zone 3 "Turtle Glass" required: Cardinal LoE3-340 laminated impact insulating Stainless steel hardware where available. DOOR TABLE Walpert Res. 5050 N Al Hutchinson Is FL 06/23/21 Comfort Line 5000 FG SGD, Impact KEY Dir Room Configurat ion Frame w x h" Opening w"x h" Hgt Flr" /Step" Area -sqft Pressure Req psf Press Rtg psf FL Appry F8-N Br2 2P2T OX 59 1/2 x 79 1/2 60 x 80 -1.5/4 32.85 +43.4 -47.4 +50-50 16112.1 F9-N Br3 2P2T OX 71 1/2 x 79 1/2 72 x 80 -1.5/4 39.47 +42.9 -46.9 +50-50 16112.1 F11-N FR 2P2T OX 71 1/2 x 79 1/2 72 x 80 -1.5/4 39.47 +42.9 -46.9 +50-50 16112.1 F12-E FR 3P2T OXO 110 x 95 1/2 110 1/2 x 96 -1.5/4 73.21 +41.4 -45.4 +50-50 16112.2 F14-SE K 2P2T OX 71 1/2 x 95 1/2 72 x 96 -1.5/4 47.42 +42.3-46.3 +50-50 16112.1 F16-NE LR 2P2T XO 71 1/2 x 95 1/2 72 x 96 -1.5/4 47.42 +42.3-46.3 +50-50 16112.1 F18-SE LR 2P2T OX 59 1/2 x 95 1/2 60 x 96 -1.5/4 39.46 +42.9 -46.9 +50-50 16112.1 F21-E MBr 2P2T OX 71 1/2 x 95 1/2 72 x 96 -1.5/4 47.42 +42.3-46.3 +50-50 16112.1 L3-E Loft 2P2T OX 71 1/2 x 95 1/2 72 x 96 -1.5/4 47.42 +42.3-46.3 +50-50 16112.1 U-30 (R-3.3), CR-58, SHGC-.18, LSG-2.11, Vis Light Trans-38%, Air Infiltration-0.126scfm/ft2@1.57psf Smooth -Pro FG with Co m osite Frame, LMI & SMI Im act KEY Configuration Frame Opening Hgt" Area P Req P Rtg FL Notes Loc'n w"x h" w"x h" Stp" -sgft psf psf Appry G4-W XX Inswing 74 x 74.5 x 0 50.33 +42.3 +50 16674.3 Water Infil NA Entry LH Active 97 15/16 98 3/8 -4 -46.3 -50 excl infil accept G10-N X Inswing 37 1/2 x 38 - x -1 25.5 +44.4 +50 16674.1 Water Infil NA Garage RH 97 15/16 98 3/8 -7 -48.4 -50 excI infil accept G13-W X Inswing 37 1/2 x 38 - x 0 25.5 +44.4 +50 16674.1 Water Infil NA N Entry LH 97 15/16 98 3/8 -3 -48.4 -50 excl infil accept G18-SE XX Inswing 74 x 74 1/2 x 0 42.11 +43.6 +50 16674.3 Water Infil NA N Store RH Active 81 15/16 82 3/8 -2 -47.6 -50 exc2; OH ratio>1 G21-E X Inswing 37 1/2 x 38 x 0 21.33 +44.9 +50 16674.1 Water Infil NA R Entry LH 81 15/16 82 3/8 -2 -48.9 -50 exc2; OH ratio>1 G24-E X Inswing 37 1/2 x 38 x 0 21.33 +44.9 +50 16674.1 Water Infil NA Equip RH 81 15/16 82 3/8 -2 -48.9 -50 exc2; OH ratio>1 F10-N X Outswing 37 1/2 x 38 x -1.5 21.13 +45.0 +50 16674.2 LowE3340 Bath3 RH 81 1/8 81 5/8 -4 -49.0 -50 Water Infil 9psf F17-E XX Outswing 74 x 74 1/2 x -1.5 49.91 +42.3 +50 16674.4 LowE3340 LR LH Active 97 1/8 97 5/8 -4 -46.3 -50 Water Infil 9psf F19-E X Outswing 37 1/2 x 38 x -1.5 21.13 +45.4 +50 16674.1 Water Infil 9psf E Bath LH 81 1/8 81 5/8 -4 -49.4 -50 M2-E X Inswing 37 1/2 x 38 x -1.5 21.13 +45.0 +50 16674.2 LowE3340 Mez Dk LH 81 1/8 81 5/8 -4 -49.0 -50 exc2; OH ratio>1 U-.29 (R-3.4), SHGC-.18, Vis Light Trans-38%, Air Infiltration-<0.3scfm/ft2 NFRC400 (overhang>height) Impact requirement Large Missile level D for Zone 3 "Turtle Glass" required: Cardinal LoV-340 laminated impact insulating R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 Product Category Sub Category Manufacturer Product Name Comfort Line Inc. 2100 Series Windows Awning 5500 Enterprise Blvd. Fiberglass Awning Window Toledo, OH 43612 'Impact' (419)729-8520 Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID # 1998) for Comfort Line Inc. based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-15974.2 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-15974.2 for size and design pressure limitations Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 02850544 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K. Wright TEL 02850545 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K. Wright TEL 02850546 ASTM E1886-05/E1996-06 Testing Evaluation Lab.,lnc. V.K. Wright 2. Miami Dade NOA Materials Testing 14-0916.11 SentryGlas Interlayer (Kuraray America, Inc.) 3. Drawing No. Prepared by No. FL-15974.2 RW Building Consultants, Inc. (CA #9813) 4. Calculations Prepared by Anchoring RW Building Consultants, Inc. (CA #9813) 5. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that Comfort Line Inc. is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. Sheet 1 of 1 Signed & Sealed by Lyndon F. Schmidt, P.E. Signed & Sealed by Lyndon F. Schmidt, P.E. ��F, SCHM�,` . ,.• •. • No 43409 • G STATE OF Q 4/: Lyndon F. Schmidt, P.E. L O R t FL PE No. 43409 i��Fss ••......••'�?�, 8/31/2017 .,et /O N, R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 Product Category Sub Category Manufacturer Product Name Comfort Line Inc. 2100 Series Windows Fixed 5500 Enterprise Blvd. Fiberglass Picture Window Toledo, OH 43612 "Impact' (419) 729-8520 Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID # 1998) for Comfort Line Inc. based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "Y and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-15973.3 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-15973.3 for size and design pressure limitations Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 02850547 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K. Wright TEL 02850548 AAMA/WDMA/101/I.S.2/A440-08 Testing Evaluation Lab.,lnc. V.K. Wright TEL 02850549 ASTM E1886-05JE1996-06 Testing Evaluation Lab.,lnc. V.K. Wright 2. Miami Dade NOA Materials Testing 14-0916.11 SentryGlas Interlayer (Kuraray America, Inc.) 3. Drawing No. Prepared by Signed & Sealed by No. FL-15973.3 RW Building Consultants, Inc. (CA#9813) r Lyndon F. Schmidt, P.E. 4. Calculations Prepared by un�,,a, e®� G, CDC-1 �,V";, 'J°e.� Signed & Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) \.�.•yiyj c �,�' Lyndon F. Schmidt, P.E. �.,e° 5. Quality AssurancenZr 4340 Certificate of Participation issued by National Accreditation andManagement Institute, certifying that Comfort Line Inc. is.manufacturing products within a quality assurance program that OF [f5a �"'--� complies with ISO/IEC 17020 and Guide 53. �. STATE °, Lyndon F. Schmidt, P.E. FL PE No. 43409 Sheet 1 of 1 8/31 /2017 R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 Product Category Sub Category Manufacturer Product Name Comfort Line Inc. Series Futura Exterior Sliding Exterior 5500 Enterprise Blvd. Fiberglass Sliding Glass Door Doors Door Assemblies Toledo, OH 43612 'Impact' (419) 729-8520 Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID # 1998) for Comfort Line Inc. based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone' (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.12.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-16112.1 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-16112.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. TEL 02850551 TEL 02850552 2. Miami Dade NOA 14-0916.11 3. Drawing No. No. FL-16112.1 4. Calculations Anchoring Test Standard AAMA/W D MA/101 /I. S.2/A440-08 ASTM E1886-05/E 1996-06 Materials Testing SentryGlas Interlayer (Kuraray America, Inc.) Prepared by RW Building Consultants, Inc. (CA #9813) Testing Laboratory Signed by Testing Evaluation Lab.,lnc. V.K. Wright Testing Evaluation Lab.,lnc. V.K. Wright Signed & Sealed by Lyndon F. Schmidt, P.E. Prepared by Signed & Sealed by RW Building Consultants, Inc. (CA#9813) ♦♦♦IIIllllt►tttt Lyndon F. Schmidt, P.E. 5. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that Comfort Line Inc. is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. ♦ I T . �, ; • �' �'• ,pi • No 43409 9 : STATE OF O �i F ' •..,;;... ' C?o�� Lyndon F. Schmidt, P.E. SoON Ae ;' FL PE o. 43409 Sheet 1 of 1 R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 Product Category Sub Category Manufacturer Product Name Comfort Line Inc. Series Futura Exterior Sliding Exterior 5500 Enterprise Blvd. Fiberglass Sliding Glass Door Doors Door Assemblies Toledo, OH 43612 'Impact' (419) 729-8520 Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID # 1998) for Comfort Line Inc. based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-16112.2 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-16112.2 for size and design pressure limitations. Supporting Documents: 1. Test Report No. TEL 02850551 TEL 02850552 2. Miami Dade NOA 14-0916.11 3. Drawing No. No. FL-16112.2 4. Calculations Anchoring Test Standard AAMA/W D MA/101 /I. S.2/A440-08 ASTM E1886-05/E 1996-06 Materials Testing SentryGlas Interlayer (Kuraray America, Inc.) Prepared by RW Building Consultants, Inc. (CA #9813) Testing Laboratory Signed by Testing Evaluation Lab.,lnc. V.K. Wright Testing Evaluation Lab.,lnc. V.K. Wright Signed & Sealed by Lyndon F. Schmidt, P.E. Prepared by Signed & Sealed by RW Building Consultants, Inc. (CA #9813) �t���e1$Ci�"A? Lyndon F. Schmidt, P.E. 5. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that Comfort Line Inc. is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. •,GENE'• No 43409 :• o STATE OFF '04"'ONA` �G,,e�� LyndonF0%FL PE No. 43409 8131 /2017 Sheet 1 of 1 BUILDING DROPS A Perfect Solution in Every Drop! �:.. Certificate of Authorization: 29578 Product Evaluation Report of JELD-WEN, inc. Design Pro / Smooth Pro / Studio Opaque (Impact) for Florida Product Approval Report No. 6264.2 398 E. Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buiIdingdrops.com Current Florida Building Code Method: 1— A (Certification Method) Category: Exterior Door Assemblies Sub — Category: Swinging Exterior Door Assemblies Product: Design Pro/ Smooth Pro/ Studio Material: Fiberglass Product Dimensions: T-0" W x 6'-8" H (Nominal) T-0" W x 8'-0" H (Nominal) Prepared for: JELD-WEN, inc 3737 Lakeport Blvd. Klamath Falls, OR. 97601 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date:09/13/2019 Contents: Evaluation Report Pages 1— 3 Digitally signed by Hermes F Norero Reason: I am approving this document Date: 2019.10.01 20:48:00-04'00' ```���ll{{ffllllff` O ,`� ••��. .... ICI L� E :�•N .7 7 OF Herl NoW6, 'P.E. Florida No. 73778 /r/)\\ BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Manufacturer: Product Category: Product Sub -Category: Compliance Method: Product Name: JELD-WEN, inc. Exterior Door Swinging Exterior Door Assemblies State Product Approval Method (1)(a) Design Pro / Smooth Pro / Studio Opaque (Impact). 3'-0" X 6'-8" (Nominal) 3'-0" X 8'-0" (Nominal) Date: 09/16/2019 Report No: 6264.2 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD-WEN, inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Hermes F Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions provided by manufacturer for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering for Wind Zone 3. An impact covering is required for Wind Zone 4. 4. Site conditions that deviate from the details of manufacturer require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions for size and design pressure limitations Hermes F Norero, P.E. Florida No.73778 Page 2 of 3 /r/)\\ BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Date: 09/16/2019 Report No: 6264.2 Certification Agency: The manufacturer has demonstrated compliance of door products in accordance with the current Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization #: CER1773) Performance Standards: The product described herein has been tested per: Referenced Data: • ASTM E283-04 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06 • AAMA 1304-02 • TAS 202-94 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization # TST1589) Report # Report Date: NCTL-210-3918-01 10/04/13 NCTL-210-3924-02 12/18/13 SJW2013-231 12/03/13 SJ W 2013-234 12/09/13 SJW2013-235 11/26/13 SJW2013-251 12/23/13 SJW2013-252 12/23/13 SJW2013-253 12/23/13 NCTL-210-3924-01 12/18/13 NCTL-210-3925-03 02/07/14 SJ W 2014-032 04/22/14 NCTL-210-3930-01 02/24/14 NCTL-210-3930-02 03/10/14 SJ W 2014-068 07/07/ 14 SJ W 2014-071 07/07/ 14 SJ W 2014-069 07/07/ 14 SJ W 2014-079 07/07/ 14 NCTL-310-19-038 07/07/14 2. Quality Assurance Entity National Accreditation & Management Institute (FBC Organization #QUA1789) Installation: Refer to Installation Instructions (D015694) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to drawing (13015694) for pressure information Hermes F Norero, P.E. Florida No.73778 Page 3 of 3 BUILDING DROPS A Perfect Solution in Every Drop! �:.. Certificate of Authorization: 29578 Product Evaluation Report of JELD-WEN, inc. Design Pro / Smooth Pro Glazed (Impact) for Florida Product Approval Report No. 6265.2 398 E. Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buiIdingdrops.com Current Florida Building Code Method: 1— A (Certification Method) Category: Exterior Door Assemblies Sub — Category: Swinging Exterior Door Assemblies Product: Design Pro/ Smooth Pro Material: Fiberglass Product Dimensions: T-0" W x 6'-8" H (Nominal) T-0" W x 8'-0" H (Nominal) Prepared for: JELD-WEN, inc 3737 Lakeport Blvd. Klamath Falls, OR. 97601 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date:09/13/2019 Contents: Evaluation Report Pages 1— 3 Digitally signed by Hermes F Norero Reason: I am approving this document Date: 2019.10.01 20:48:41-04'00' ```���ll{{ffllllff` O ,`� ••��. .... ICI L� E :�•N .7 7 OF Herl NoW6, 'P.E. Florida No. 73778 /r/)\\ BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Manufacturer: Product Category: Product Sub -Category: Compliance Method: Product Name: JELD-WEN, inc. Exterior Door Swinging Exterior Door Assemblies State Product Approval Method (1)(a) Design Pro / Smooth Pro Glazed (Impact). 3'-0" X 6'-8" (Nominal) 3'-0" X 8'-0" (Nominal) Date: 09/13/2019 Report No: 6265.2 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD-WEN, inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Hermes F Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions provided by manufacturer for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering for Wind Zone 3. An impact covering is required for Wind Zone 4. 4. Site conditions that deviate from the details of manufacturer require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions for size and design pressure limitations Certification Agency: The manufacturer has demonstrated compliance of door products in accordance with the current Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization #: CER1773) Hermes F Norero, P.E. Florida No.73778 Page 2 of 3 /r/)\\ BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Performance Standards: The product described herein has been tested per: Referenced Data: • ASTM E283-04 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06 • AAMA 1304-02 • TAS 202-94 Date: 09/13/2019 Report No: 6265.2 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization # TST1589) Report # Report Date: SJW2013-196 09/03/13 SJW2013-129 08/09/13 SJ W 2013-234 12/09/13 SJW2013-235 11/26/13 SJW2013-251 12/23/13 SJW2013-252 12/23/13 SJW2013-253 12/23/13 NCTL-210-3924-01 12/18/13 NCTL-210-3925-03 02/07/14 NCTL-210-3930-01 02/24/14 NCTL-210-3930-02 03/10/14 SJ W 2014-070 07/07/ 14 SJ W 2014-075 07/07/ 14 2. Product Testing performed by Quality Testing Inc. (FBC Organization # TST7638) Report # Report Date: SJ W 2010-003 01/ 11/ 10 3. Quality Assurance Entity National Accreditation & Management Institute (FBC Organization #QUA1789) Installation: Refer to Installation Instructions (D015695) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to drawing (13015695) for pressure information Hermes F Norero, P.E. Florida No.73778 Page 3 of 3 BUILDING DROPS A Perfect Solution in Every Drop! �:.. Certificate of Authorization: 29578 Product Evaluation Report of JELD-WEN, inc. Design Pro / Smooth Pro Opaque (Impact) for Florida Product Approval Report No. 6266.2 398 E. Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buiIdingdrops.com Current Florida Building Code Method: 1— A (Certification Method) Category: Exterior Door Assemblies Sub — Category: Swinging Exterior Door Assemblies Product: Design Pro/ Smooth Pro Material: Fiberglass Product Dimensions: 6'-0" W x 6'-8" H (Nominal) 6'-0" W x 8'-0" H (Nominal) Prepared for: JELD-WEN, inc 3737 Lakeport Blvd. Klamath Falls, OR. 97601 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date:09/13/2019 Contents: Evaluation Report Pages 1— 3 Digitally signed by Hermes F Norero Reason: I am approving this document Date: 2019.10.01 20:49:36-04'00' ```���ll{{ffllllff` O ,`� ••��. .... ICI L� E :�•N .7 7 OF Herl NoW6, 'P.E. Florida No. 73778 /r/)\\ BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Manufacturer: Product Category: Product Sub -Category: Compliance Method: Product Name: JELD-WEN, inc. Exterior Door Swinging Exterior Door Assemblies State Product Approval Method (1)(a) Design Pro / Smooth Pro Opaque (Impact). 6'-0" X 6'-8" (Nominal) 6'-0" X 8'-0" (Nominal) Date: 09/13/2019 Report No: 6266.2 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD-WEN, inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Hermes F Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions provided by manufacturer for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering for Wind Zone 3. An impact covering is required for Wind Zone 4. 4. Site conditions that deviate from the details of manufacturer require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions for size and design pressure limitations Certification Agency: The manufacturer has demonstrated compliance of door products in accordance with the current Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization #: CER1773) Hermes F Norero, P.E. Florida No.73778 Page 2 of 3 /r/)\\ BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Performance Standards: The product described herein has been tested per: Referenced Data: • ASTM E283-04 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06 • AAMA 1304-02 • TAS 202-94 Date: 09/13/2019 Report No: 6266.2 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization # TST1589) Report # Report Date: SJW2013-196 09/03/13 SJW2013-129 08/09/13 SJ W 2013-234 12/09/13 SJW2013-235 11/26/13 SJW2013-251 12/23/13 SJW2013-252 12/23/13 SJW2013-253 12/23/13 NCTL-210-3924-01 12/18/13 NCTL-210-3925-03 02/07/14 NCTL-210-3930-01 02/24/14 NCTL-210-3930-02 03/10/14 SJ W 2014-070 07/07/ 14 SJ W 2014-075 07/07/ 14 2. Quality Assurance Entity National Accreditation & Management Institute (FBC Organization #QUA1789) Installation: Refer to Installation Instructions (D015696) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to drawing (13015696) for pressure information Hermes F Norero, P.E. Florida No.73778 Page 3 of 3 BUILDING DROPS A Perfect Solution in Every Drop! �:.. Certificate of Authorization: 29578 Product Evaluation Report of JELD-WEN, inc. Design Pro / Smooth Pro Glazed (Impact) for Florida Product Approval Report No. 6267.2 398 E. Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buiIdingdrops.com Current Florida Building Code Method: 1— A (Certification Method) Category: Exterior Door Assemblies Sub — Category: Swinging Exterior Door Assemblies Product: Design Pro/ Smooth Pro Material: Fiberglass Product Dimensions: 6'-0" W x 6'-8" H (Nominal) 6'-0" W x 8'-0" H (Nominal) Prepared for: JELD-WEN, inc 3737 Lakeport Blvd. Klamath Falls, OR. 97601 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date:09/13/2019 Contents: Evaluation Report Pages 1— 3 Digitally signed by Hermes F Norero Reason: I am approving this document Date: 2019.10.01 20:50:16-04'00' ```���ll{{ffllllff` O ,`� ••��. .... ICI L� E :�•N .7 7 OF Herl NoW6, 'P.E. Florida No. 73778 /r/)\\ BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Manufacturer: Product Category: Product Sub -Category: Compliance Method: Product Name: JELD-WEN, inc. Exterior Door Swinging Exterior Door Assemblies State Product Approval Method (1)(a) Design Pro / Smooth Pro Glazed (Impact). 6'-0" X 6'-8" (Nominal) 6'-0" X 8'-0" (Nominal) Date: 09/13/2019 Report No: 6267.2 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD-WEN, inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Hermes F Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions provided by manufacturer for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering for Wind Zone 3. An impact covering is required for Wind Zone 4. 4. Site conditions that deviate from the details of manufacturer require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions for size and design pressure limitations Certification Agency: The manufacturer has demonstrated compliance of door products in accordance with the current Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization #: CER1773) Hermes F Norero, P.E. Florida No.73778 Page 2 of 3 /r/)\\ BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Performance Standards: The product described herein has been tested per: Referenced Data: • ASTM E283-04 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06 • AAMA 1304-02 • TAS 202-94 Date: 09/13/2019 Report No: 6267.2 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization # TST1589) Report # Report Date: NCTL-210-3918-01 10/04/13 NCTL-210-3924-02 12/18/13 SJ W 2013-234 12/09/13 SJW2013-235 11/26/13 SJW2013-251 12/23/13 SJW2013-252 12/23/13 SJW2013-253 12/23/13 NCTL-210-3924-01 12/18/13 NCTL-210-3925-03 02/07/14 SJ W 2014-032 04/22/14 NCTL-210-3930-01 02/24/14 NCTL-210-3930-02 03/10/14 SJ W 2014-069 07/07/ 14 SJ W 2014-079 07/07/ 14 NCTL-310-19-038 03/29/19 2. Quality Assurance Entity National Accreditation & Management Institute (FBC Organization #QUA1789) Installation: Refer to Installation Instructions (D015697) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to drawing (13015697) for pressure information Hermes F Norero, P.E. Florida No.73778 Page 3 of 3 ICC-ES Evaluation Report ESR-1748 Reissued October 2020 This report is subject to renewal October 2021. wwwAcc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council ° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 24 00—Exterior Insulation and Finish Systems Section: 07 24 19—Water-Drainage Exterior Insulation and Finish System REPORT HOLDER: STO CORP. ADDITIONAL LISTEE: KAPTURE PREFAB EVALUATION SUBJECT: STOTHERM° ci°, STOPANELTM CLASSIC ci°, STOPANELTM IMPACT ci°, STOPANELTM XPS AND STOPANELT" CLASSIC NEXT ci° 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2018, 2015 and 2012 International Building Code° (IBC) ■ 2018, 2015 and 2012 International Residential Code° (IRC) For evaluation for compliance with codes adopted by Los Angeles Department of Building and Safety (LADBS), see ESR-1748 LABC and LARC Supplement. Properties evaluated: PROPERTY IBC IRC Chapter Chapter Exterior insulation and finish 14 R7 systems (EIFS) Fire -resistance -rated construction 7 R3 Weather resistance 14 R7 Special inspections, Types I -IV 17 NA (noncombustible) construction Structural — transverse wind load 16 R6 resistance Types I -IV (noncombustible) 26 NA construction Surface burning characteristics 26 R3 Ignition resistance 26 NA 2.0 USES StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems are exterior insulation and finish systems (EIFS) complying with 2018 IBC Section 1407 and 2015 and 2012 IBC Section 1408 and IRC Section R703.9. The systems comply with the requirements of 2018 IBC Section 1407.4.1 and 2015 and 2012 IBC Section 1408.4.1 and IRC Section R703.9 as EIFS with drainage. StoTherm° ci° StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems may be installed in buildings of any construction type under the IBC (Types I through V) and dwellings under the IRC when installed in accordance with the applicable sections of Section 4.0. 3.0 DESCRIPTION 3.1 System Components: StoTherm° ci° StoPanelTM Classic ci° Classic, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelT"" Classic NEXT ci° systems consist of a water -resistive barrier, adhesively applied flat insulation board, reinforcing mesh, base coat, and finish coat. See Table 1 for system components. 3.2 Insulation Board: The insulation boards must be one of the following: a. Expanded polystyrene (EPS) complying with ASTM C578, Type I, and ASTM E2430, produced by a molder with a current ICC-ES evaluation report. b. EPS insulation board produced by a molder who participates in an approved third -party quality - assurance program. EPS must comply with ASTM C578, Type I, and ASTM E2430. c. Sto Insulation Board, EPS complying with ASTM C578, Type I, and ASTM E2430. d. Owens Corning Foamular° CI-C Extruded Polystyrene Type X (for use with the StoTherm° ci° XPS system as noted in Table 1). e. Dow Styrofoam Panel Core Type X recognized in ESR-2142 (for use with the StoTherm° ci° XPS system noted in Table 1). f. BASF Neopor° Rigid Foam Insulation Board (Grade F5300 Plus) (for use with StoTherm° ci° Classic, StoTherm° ci° Premier, StoTherm° ci° Essence, and StoTherm° ci° Lotusan systems as noted in Table 1). ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as i to any finding or other matter in this report, or as to any product covered by the report. mum Copyright© 2020 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 9 ESR-1748 I Most Widely Accepted and Trusted Page 2 of 9 EPS insulation boards must have a flame spread index of 25 or less and a smoke -developed index of 450 or less when tested in accordance with ASTM E84 or UL 723. 3.3 Substrates: Substrates must be one of the following: a. Gypsum sheathing board complying with ASTM C1396 or ASTM C1177. When used as part of a fire -resistance -rated assembly, the gypsum board must be Type X with a minimum thickness of 5/8 inch (15.9 mm). b. Concrete masonry complying with the code. c. Concrete complying with the code. d. Exterior plaster complying with the code. e. Exterior or Exposure 1 wood structural panels complying with DOC PS-1 or PS-2. 3.4 Sealants: Sealants must comply with ASTM C920, Type S or M, minimum Grade NS, minimum Class 25 and Use O. 4.0 DESIGN AND INSTALLATION 4.1 General: 4.1.1 StoTherm° ci°: StoTherm° ci° must be installed in accordance with the manufacturer's installation instructions, specifications and details, which are available at www.stocorp.com: • http://www.stocorp.com/continuous-insulation-systems/ • htti3://www.stocorp.com/sto systems/stothermci-xps- lotusan/ • htti3://www.stocorp.com/sto systems/stothermci-classic/ • htti3://www.stocorp.com/sto systems/stothermci-lotusan/ • htti3://www.stocorp.com/sto systems/stothermci-xps- essence/ • http://www.stocorp.com/sto systems/stothermci-xps classic/ • htti3://www.stocorp.com/sto systems/stothermci- essence/ 4.1.2 StoPanelTM Classic ci°: StoPanelTM Classic ci° system is a prefabricated application by Kapture Prefab of the StoTherm° ci° Classic system. Sto materials, as listed in Table 6, must be installed in accordance with the specifications and installation instructions in Section 4.1.1. StoPanelTM Classic ci° system must be fabricated in accordance with project specification and StoPanelTM fabricator shop drawings for each project. • StoPanelTM Classic ci° • Specification 4.1.3 StoPanelTM Impact ci°: StoPanelTM Impact ci° system is a prefabricated application by Kapture Prefab of the StoTherm° Impact ci° system. Sto materials, as listed in Table 6, must be installed in accordance with the specifications and installation instructions in Section 4.1.1. StoPanelTM Impact ci° system must be fabricated in accordance with project specification and StoPanelTM fabricator shop drawings for each project. • StoPanel Impact cie • Specification 4.1.4 StoPanelTM XPS: StoPanelTM XPS system is a prefabricated application by Kapture Prefab of the StoTherm° XPS system. Sto materials, as listed in Table 6, must be installed in accordance with the specifications and installation instructions in Section 4.1.1. StoPanelTM XPS system must be fabricated in accordance with project specification and StoPanelTM fabricator shop drawings for each project. • StoPanelTM XPS • Specification 4.1.5 StoPanelTM Classic NEXT ci°: StoPanelTM Classic NEXT ci° system is a prefabricated application by Kapture Prefab of the StoTherm° ci° system which also incorporates the Sto Wedge drainage detail. Sto materials, as listed in Table 6, must be installed in accordance with the specifications and installation instructions in Section 4.1.1. StoPanelTM Classic NEXT ci° system must be fabricated in accordance with project specification and StoPanelTM fabricator shop drawings for each project. • StoPanelTM Classic NEXT ci° • Specification 4.2 Drainage: StoTherm° ci° ,StoPanelTM ci° Classic, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° provides drainage through the application of vertical ribbons of adhesive over the water -resistive barrier coating system identified in Table 1. Additional installation and compliance information for the Sto Gold Coat water -resistive barrier system is provided in ESR-1233 and at www.stocorp.com. 4.3 Wind Design: Table 3 presents specific StoTherm° ci° assemblies for which test data has been submitted. Other StoTherm° ci° assemblies may be considered for approval by local officials, based on testing and/or calculations provided by a qualified design professional. 4.4 Weather Protection: StoTherm° ci° ,StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems comply with 2018 IBC Section 1402.2 and 2015 and 2012 IBC Section 1403.2 and IRC Section R703.1.1. 4.5 Use in Types I through IV (Noncombustible) Construction: Table 4 describes the assemblies qualified for use in Types I through IV construction (IBC). 4.6 Fire -resistance -rated Construction: Table 5 describes the assemblies qualified for use in nonload-bearing fire -resistance -rated construction. In addition, in Type V construction, any StoTherm° ci° system listed in this report may be attached to the surface of combustible exterior fire -resistance -rated assemblies described in IBC Table 721.1(2) without changing the assigned hourly rating of the assembly. The exterior wall must have a minimum 10-foot (3048 mm) separation distance from adjacent construction. 4.7 Special Inspection: For recognition under the IBC, special Inspections of the water -resistive barrier must be conducted in accordance with 2018 and 2015 IBC Section 1705.16 (2012 IBC Section ESR-1748 I Most Widely Accepted and Trusted Page 3 of 9 1705.15). Refer to STO Corp. third -party inspection guidelines for verifying field preparation of materials. 5.0 CONDITIONS OF USE The StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° EIFS systems described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with this report, the manufacturer's published installation instructions and the applicable code. In the event of a conflict between the manufacturer's instructions and this report, this report governs. 5.2 The insulation board must be separated from the building interior by a thermal barrier complying with the applicable code. 5.3 Installation must be by applicators listed by Sto Corp. StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS StoPanelTM Classic NEXT ci° must be fabricated by Kapture Prefab and installed in accordance with Sto instructions. 5.4 Termination of the systems must not be less than 6 inches (152 mm) above finished grade in accordance with 2018 and 2015 IBC Section 2603.8 (2012 IBC Section 2603.9) and IRC Section R318.4. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with ASTM E2568 and ASTM E2273. 6.2 Data in accordance with the ICC-ES Acceptance Criteria for EIFS Clad Drainage Wall Assemblies (AC235), dated January 2015 (editorially revised April 2018). 6.3 Data in accordance with the ICC-ES Acceptance Criteria for Foam Plastic Insulation (AC12), dated June 2015 (editorially revised October 2017). 6.4 NFPA 285 and NFPA 268 test data, including engineering analysis. 7.0 IDENTIFICATION 7.1 Each container or package of the coating or reinforcing mesh used as part of the StoTherm°EIFS ci° systems components must be labeled with the manufacturer's name (STO Corp.) and address; the product name; lot or batch number; quantity of material; storage instructions; pot life; expiration date; and the evaluation report number (ESR-1748). Sto insulation board must be labeled on the edge of each board with the STO Corp. name, the plant identification number, and the evaluation report number (ESR-1748). Sto Turbostick and Sto Turbostick Mini adhesive must be labeled with the Sto Corporation company name and product name designation. Other foam plastic insulation must be labeled in accordance with the current ICC-ES evaluation report in which it is recognized, or in accordance with IBC Section 2603.2 or IRC Section R316.2, as applicable. StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS StoPanelTM Classic NEXT ci° prefabricated panels are produced by Kapture Prefab and shipped with a certificate of compliance that contains the project identification the panels were produced for, dates of panel fabrication and a statement that all components of the panels complies with the applicable requirements of ESR-1748. 7.2 The report holder's contact information is the following: STO CORP. 3800 CAMP CREEK PARKWAY BUILDING 1400, SUITE 120 ATLANTA, GEORGIA 30331 (800) 221-2397 www.stocorp.com 7.3 The Additional Listee's contact information is the following: KAPTURE PREFAB 421 WEST ALAMEDA DRIVE TEMPE, ARIZONA 85282 ESR-1748 I Most Widely Accepted and Trusted Page 4 of 9 TABLE 1—STOTHERM® cio SYSTEM COMPONENTS1,2 WATER -RESISTIVE ASTM C578 SYSTEM BARRIER INSULATION BOARD ADHESIVES BASE COATS FINISH TYPE 80265-81636 Sto BTS Plus Sto BTS Plus Sto Gold Coat Sto BTS Silo Sto BTS Silo Stolit StoTherm® cio Classic 81210 Sto AirSeal Type I° Sto BTS Xtra Stolit Milano3 80263 Sto VaporSeal Sto TurboStick Sto BTS Xtra Stolit X3 (see E5R-1233) Sto TurboStick Mini Sto RFP 80265-81636 Sto BTS Plus Sto BTS Plus Sto Gold Coat Sto BTS Silo Sto BTS Silo StoTherm® cio Premier 81210 Sto AirSeal Type I° Sto BTS Xtra StoSilco Lit 80263 Sto VaporSeal Sto TurboStick Sto BTS Xtra (see E5R-1233) Sto TurboStick Mini Sto RFP 80265-81636 Sto Primer/Adhesive Sto DPR StoTherm® cie Essence Sto Gold Coat 81210 Sto AirSeal Type I° Sto Primer/Adhesive-B Sto Primer/Adhesive Finish 80263 Sto VaporSeal Sto TurboStick Sto Primer/Adhesive-B Stolit Milano (see E5R-1233) Sto TurboStick Mini Stolit X 80265-81636 Sto BTS Plus Sto BTS Plus Sto Gold Coat Sto BTS Silo Sto BTS Silo Stolit Lotusan StoTherm® cio Lotusan 81210 Sto AirSeal Type I° Sto BTS Xtra 80263 Sto VaporSeal Sto TurboStick Sto BTS Xtra (see E5R-1233) Sto TurboStick Mini Sto RFP 80265-81636 Sto BTS Plus Stolit Sto Gold Coat StoTherm® cio XPS 81210 Sto AirSeal Type X Sto TurboStick Sto BTS Xtra Stolit Lotusan 80263 Sto VaporSeal Sto TurboStick Mini Sto Primer/Adhesive Stolit Milano (see E5R-1233) Sto Primer/Adhesive-B Stolit X 'All base coats are reinforced with the appropriate Sto Mesh product listed in Table 2. 2Sto Primer is an optional component of the systems listed above. 3Sto BTS Silo basecoat is not recognized for use with Stolit Milano and Stolit X finish. 4Reference Section 3.2(f) for alternate insulation board. TABLE 2—REINFORCING MESH PRODUCTS PRODUCT NO. PRODUCT NAME' NOMINAL WEIGHT, ozlyd' (glm') 80920E Sto Mesh 4.5(153) 80919 Sto Detail Mesh 4.2(142) 80985 Sto 6-oz. (170 g) Mesh 6.0(170) 80918 Sto Intermediate Mesh 11.0 (373) 80921 Sto Armor Mat 15.0 (509) 80922 Sto Armor Mat XX 20.0 (678) 80921A Sto Cormer Mat 7.6(258) 'Other listed mesh products may be used for detail construction or to supplement impact resistance of the EIFS. ESR-1748 I Most Widely Accepted and Trusted Page 5 of 9 TABLE 3—WIND LOAD DESIGN' WIND LOAD FRAMING MEMBERS2 SHEATHING CAPACITY, psf (Pa) SYSTEM Wood, Metal Maximum Maximum Fastener min. size Spacing Type Thickness inch ( ) Spacing3, Neg. Pos. Min. Depth Min. (inches) (inches) Gage (inches) (inches) 2x4 16 Wood -based 3/8 8 20 36 Classic (nominal) Premier 31/2 18 16 Wood -based 3/8 8 38 60 Essence Classic 31/2 18 16 Gypsum 1/2 8 20 35 Premier Essence Lotusan StoPanelTM (See Table 6) 31/2 18 16 Gypsum 5/8 8 38 60 Essence StoPaneITM (See Table 6) Classic Premier Essence Lotusan (with Turbo Stick 6 18 16 Gypsum 5/8 6 40 50 Adhesive or Sto TurboStick Mini and Type I EPS) StoPanelTM (See Table 6) 6 18 16 Gypsum 5/8 6 63 58 StoTherm ci® XPS StoPaneITM (See Table 6) Classic Concrete or masonry substrates 54 54 Premier Lotusan For SI: 1 inch = 25.4 mm, 1 psf = 0.0479 kPa. 'Applicable to all StoTherm® materials listed in Tables 1 and 2. 2Deflection limitation 1/24o, designed in accordance with applicable code. 3Fasteners must be No. 6, flathead, corrosion -resistant screws [minimum 0.292-inch (7.4 mm) head diameter]. TABLE 4—ASSEMBLIES FOR USE IN TYPES I THROUGH IV CONSTRUCTION FRAMING MEMBERS" INTERIOR SHEATHING'' EXTERIOR SHEATHING MAX. (TYPE X GYPSUM) (TYPE X GYPSUM) INSULATION BOARD THICKNESS, (inches) SYSTEM' Metal Max. Spacing Min. Thickness Max. Fastener Spacing Min. Thickness Max. Fastener Spacing Min. Depth Min. (inches) Gage (inches) (inch) (inches) (inch) (inches) 31/2 18 16 1 /2 8 at perimeter 12 /2 6 at perimeter 12 Essence Lotusan 12 in field 8 in field3 StoPanelTM (See Table 6) Classic 31/2 18 166 1/2 64 5/8 6 at perimeter 12 Premier 8 in field3 Lotusan StoPanelTM See Table 6 StoTherm® ci Essence with Sto TurboStick, Sto TurboStick Mini, Sto 61/4 20 16 5/8 84 5/8 84 12 Prim er/Adh esive-B base coat and Stolit X finish StoPanelTA° See Table 6 8 at perimeter 8 at perimeter Classic with Turbo Stick adhesive and 1 3 /2 18 16 6 s /8 12 in field s /8 12 in field 9 Type I EPS StoPanelTM See Table 6 StoTherm® ci® XPS with Sto BTS Xtra 31/2 18 16 e s /8 8 at perimeter s /8 8 at perimeter 6 base coat and Stolit finish 12 in field 12 in field StoPanelTM See Table 6 For SI: 1 inch = 25.4 mm. 'All board joints backed by framing. 2Fasteners are minimum No. 8, Type S, corrosion -resistant screws, with sufficient length to penetrate framing a minimum of % inch (9.5 mm). 3Fasteners are No. 6 drywall screws having sufficient length to penetrate framing a minimum of % inch (9.5 mm). 4Fasteners are No. 6 by 11/4-inch-long (31.7 mm), buglehead drywall screws. 5Stud cavities at floor levels are blocked with Owens Corning Thermafiber insulation , 4 Ib/ft3 (64 kg/m3) density, 4 inches (102 mm) thick and 2 feet (610 mm) wide. 6Stud cavities must be filled with R-11 fiberglass insulation. 7AII joints must be taped and treated with joint compound. Intermediate fastener heads are treated with joint compound in accordance with ASTM C840 or GA216. 80penings must be framed with minimum 0.0428-inch-thick steel framing. 9Applicable to StoTherm® ci® and StoPanelTM systems listed in Tables 1, 4 and 6, except for StoTherm® ci® and StoPanelTM systems using Stolit Milano and Stolit X finish, unless noted otherwise. ESR-1748 I Most Widely Accepted and Trusted Page 6 of 9 TABLE 5—FIRE-RESISTANCE-RATED ASSEMBLIES1,2 FRAMING MEMBERS INTERIOR SHEATHING EXTERIOR SHEATHING MAXIMUM FIRE- Min. Min. Max. Type Min. Max. Type Min. Max. EPS RESISTANCE Depth Gage Spacing Thickness Fastener Thickness Fastener INSULATION RATING (inches) (inches) (inch) Spacing (inch) Spacings BOARD (hrs) (inches) (inches) THICKNESS (inches) 8 o.c. on 6 at 1 31/2 18 16 Type XS 5/8 perimeter Type X 5/8 perimeter 4 gypsum 12 o.c. in gypsum 8 in field field' Two layers Base layer Two layers Base layer 2 31/2 18 16 of Type X 5/8 at 24 o.c. of Type X 5/8 at 24 o.c. 4 gypsum 5 Face layer gypsum Face layer at 8 o.c.1 at 8 o.c.' For SI: 1 inch = 25.4 mm. 'Applicable to all StoTherm® ci® and StoPanelTm materials listed in Table 1, except to StoTherm® ci® and StoPanelTM systems which use the Stolit Milano, Stolit X and Sto Turbo Stick or Sto TurboStick Mini adhesive. 2All board joints must be blocked 3Fasteners are minimum No. 6, 11/4-inch-long (32 mm), self -tapping, corrosion -resistant bugle head screws. 4Fasteners are No. 6 drywall screws having sufficient length to penetrate framing a minimum of % inch (9.5 mm). 51nterior wallboard joints must be covered with tape and joint compound. Interior fastener heads are covered with joint compound in accordance with ASTM C840 or GA 216. SFasteners for the base layer of gypsum board are No. 6, 11/4-inch-long, self -tapping, corrosion -resistant bugle -head screws. Fasteners for the face layer are 17/8- inch-long, self -tapping, corrosion -resistant bugle -head screws. TABLE 6—STOPANELT" COMPONENTSI,2 WATER -RESISTIVE ASTM C578 SYSTEM INSULATION ADHESIVES BASE COATS FINISH BARRIER BOARD TYPE 80265-81636 Sto BTS Plus Sto BTS Plus Stolit Sto Gold Coat Type I Sto BTS Silo Sto BTS Silo Stolit Milano3 StoPanelTM Classic ci° 81210 Sto AirSeal Sto BTS Xtra Sto BTS Xtra Stolit X3 80263 Sto VaporSeal Sto TurboStick (see E5R1233) Sto TurboStick Mini Sto RFP 80265-81636 Sto BTS Plus Sto BTS Plus Stolit StoPanelTM Classic Sto Gold Coat Type I Sto BTS Silo Sto BTS Silo Stolit Milano3 NEXT ci° 81210 Sto AirSeal Sto BTS Xtra Sto BTS Xtra Stolit X3 80263 Sto VaporSeal Sto TurboStick (see E5R1233) Sto TurboStick Mini Sto RFP 80265-81636 Sto BTS Plus Sto BTS Plus Sto Gold Coat Type I Sto BTS Silo Sto BTS Silo StoSilco Lit StoPanelTM Impact ci'� 81210 Sto AirSeal Sto BTS Xtra 80263 Sto VaporSeal Sto TurboStick Sto BTS Xtra (see ESR-1233) Sto TurboStick Mini Sto RFP 80265-81636 Sto BTS Plus Stolit Sto Gold Coat Type X Sto TurboStick Sto BTS Xtra Stolit Lotusan StoPanelTA° XPS 81210 Sto AirSeal Sto TurboStick Mini Sto Primer/Adhesive Stolit Milano 80263 Sto VaporSeal (see E5R1233) Sto Primer/Adhesive-B Stolit X 'All base coats are reinforced with the appropriate Sto Mesh product listed in Table 2. 2Sto Primer is an optional component of the systems listed above. 3Sto BTS Silo basecoat is not recognized for use with Stolit Milano and Stolit X finish. IMES Evaluation Report ESR-1748 LABC and LARC Supplement Reissued October 2020 This report is subject to renewal October 2021. wwwAcc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council ° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 24 00—Exterior Insulation and Finish Systems Section: 07 24 19—Water-Drainage Exterior Insulation and Finish System REPORT HOLDER: STO CORP. EVALUATION SUBJECT: STOTHERM° ci°, STOPANELTM CLASSIC ci°, STOPANELTM IMPACT cia, STOPANELTM XPS AND STOPANELTM CLASSIC NEXT ci® 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that StoTherm° ci°, StoPanelTM Classic ci®, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems, described in ICC-ES evaluation report ESR-1748, have also been evaluated for compliance with the codes noted below as adopted by Los Angeles Department of Building and Safety (LADBS). ■ 2020 City of Los Angeles Building Code (LABC) ■ 2020 City of Los Angeles Residential Code (LARC) 2.0 CONCLUSIONS The StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPaneIT"" Classic NEXT ci° systems, described in Sections 2.0 through 7.0 of the ICC-ES evaluation report ESR-1748, comply with LABC Chapters 7, 14 and 26, and LARC Sections R316 and R703, subject to the conditions of use described in this report. 3.0 CONDITIONS OF USE The StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems described in this evaluation report supplement must comply with all of the following conditions: • All applicable sections in the ICC-ES evaluation report ESR-1748. • The design, installation, conditions of use and labeling of the StoTherm° ci°, StoPanelTM Classic ci®, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelT"" Classic NEXT ci° systems are in accordance with the 2018 International Building Code° (2018 IBC) or 2018 International Residential Code° (2018 IRC) provisions, as applicable, noted in the ICC-ES evaluation report ESR-1748. • The design, installation and inspection are in accordance with additional requirements of LABC Chapters 16 and 17, as applicable. This supplement expires concurrently with the evaluation report, reissued October 2020. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as i to any finding or other matter in this report, or as to any product covered by the report. mum Copyright© 2020 ICC Evaluation Service, LLC. All rights reserved. Page 7 of 9 IMES Evaluation Report ESR-1748 CBC and CRC Supplement Reissued October 2020 This report is subject to renewal October 2021. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council ° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 24 00—Exterior Insulation and Finish Systems Section: 07 24 19—Water-Drainage Exterior Insulation and Finish System REPORT HOLDER: STO CORP. EVALUATION SUBJECT: STOTHERM° ci°, STOPANELTM CLASSIC ci°, STOPANELTM IMPACT ci°, STOPANELTM XPS AND STOPANELTM CLASSIC NEXT ci° 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems, described in ICC-ES evaluation report ESR-1748, have also been evaluated for compliance with the codes noted below. Applicable code edition(s): ■ 2019 California Building Code° (CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD) and Division of State Architect (DSA), see Sections 2.1.1 and 2.1.2 below. ■ 2019 California Residential Code° (CRC) 2.0 CONCLUSIONS 2.1 CBC: The StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems described in Sections 2.0 through 7.0 of the ICC-ES evaluation report ESR-1748, complies with 2019 CBC Chapter 14, provided the design and installation are in accordance with the 2018 International Building Code° (IBC) provisions respectively, noted in the main report and the additional requirements of CBC Chapters 14 and 17. 2.1.1 OSHPD: The applicable OSHPD Sections of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections of the CBC are beyond the scope of this supplement. 2.2 CRC: The StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems, described in Sections 2.0 through 7.0 of the ICC-ES evaluation report ESR-1748, complies with the 2019 CRC Chapter 7, provided the design and installation are in accordance with the 2018 International Residential Code° (IRC) provisions respectively, noted in the main report and the applicable provisions of the CRC. This supplement expires concurrently with the evaluation report, reissued October 2020. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. 7 a Copyright© 2020 ICC Evaluation Service, LLC. All rights reserved. Page 8 of 9 ICC-ES Evaluation Report ESR-1748 FBC Supplement Reissued October 2020 This report is subject to renewal October 2021. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council ° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 24 00—Exterior Insulation and Finish Systems Section: 07 24 19—Water-Drainage Exterior Insulation and Finish System REPORT HOLDER: STO CORP. EVALUATION SUBJECT: STOTHERM° ci°, STOPANELTM CLASSIC ci°, STOPANELT"^ IMPACT ci°, STOPANELTM XPS AND STOPANELTM CLASSIC NEXT ci® 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that StoTherm° c0% StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems, described in ICC-ES ICC-ES evaluation report ESR-1748, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2020 Florida Building Code —Building ■ 2020 Florida Building Code —Residential 2.0 CONCLUSIONS The StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems, described in Sections 2.0 through 7.0 of the ICC-ES evaluation report ESR-1748, comply with the Florida Building Code —Building and Florida Building Code —Residential, provided the design and installation are in accordance with the 2018 International Building Code° provisions noted in the ICC-ES report under the following condition: Installation must meet the requirements of Sections 1403.8 and 2603.8 of the Florida Building Code —Building and Sections R318.7 and R318.8 of the Florida Building Code —Residential, as applicable. Use of the StoTherm° ci°, StoPanelTM Classic ci°, StoPanelTM Impact ci°, StoPanelTM XPS and StoPanelTM Classic NEXT ci° systems for compliance with the High -Velocity Hurricane Zone provisions of the Florida Building Code —Building and the Florida Building Code —Residential has not been evaluated and is outside the scope of this evaluation report. For products falling under Florida Rule 9N-3, verification that the report holder's quality -assurance program is audited by a quality -assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the evaluation report, reissued October 2020. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as i to any finding or other matter in this report, or as to any product covered by the report. "W Copyright © 2020 ICC Evaluation Service, LLC. All rights reserved. Page 9 of 9 CREEK Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7T" EDITION (2020) Manufacturer: SIKA CORPORATION Issued August 9, 2020 201 Polito Avenue Lyndhurst, NJ 07071 (201) 568-9300 Quality Assurance: PRI Construction Materials, LLC (QUA9110) SCOPE Category: Roofing Subcategory: Waterproofing Code Edition: Florida Building Code, 7"' Edition (2020) including High -Velocity Hurricane Zones (HVHZ) Code Sections: 1504.3.1, 1507.15.2, 1515.1.1, 1515.1.4, 1519.16, 1523.1.1 Properties: Wind Resistance REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) LPI-045-02-01 ASTM D 7311/D 7311M 2010 PRI Construction Materials Technologies (TST5878) LPI-046-02-01 ASTM C 297 2010 PRI Construction Materials Technologies (TST5878) LPI-049-02-01 ANSI/FM 4474(B) 2011 TAS 114(D) 2011 PRI Construction Materials Technologies (TST5878) LPI-049-02-02 ANSI/FM 4474(B) 2011 TAS 114(D) 2011 PRI Construction Materials Technologies (TST5878) LPI-052-02-01 ASTM C 836 2015 PRI Construction Materials Technologies (TST5878) LPI-062-02-01 ANSI/FM 4474(B) 2011 TAS 114(D) 2011 PRI Construction Materials Technologies (TST5878) LPI-070-02-01.1 ASTM D 4541 2009e1 PRI Construction Materials Technologies (TST5878) LPI-072-02-01.1 ASTM D 4541 2009e1 PRI Construction Materials Technologies (TST5878) LPI-078-02-01.1 ASTM D 562 2010(2014) ASTM D 1475 2013 ASTM D 1644 2001(2017) ASTM E 96/E 96M 2015 PRI Construction Materials Technologies (TST5878) LPI-083-02-01 ASTM D 6083 2018 PRI Construction Materials Technologies (TST5878) LPI-083-02-01A ASTM D 4541 2009e1 SIKA14001.4 FL17440-R4 Page 1 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC PRODUCT DESCRIPTIONS & APPLICATION SIKA CORPORATION Sikalastic RoofPro Roofing and Waterproofing Systems Use Products Description Sika Bonding Primer Two -component, water -based, epoxy primer applied at a rate of 200-300 ftZ/gal depending on substrate profile and porosity Sikalastic DTE Primer Two -component, epoxy primer applied at a rate of 200 ftZ/gal Sikalastic EP Two -component, epoxy primer applied at a rate of 100-250 ftZ/gal depending on Primer Primer/Sealer substrate profile and porosity Sikalastic Concrete Single -component, low odor moisture -curing polyurethane resin applied at a rate Primer Lo-VOC of 225-375 ftZ/gal depending on substrate profile and porosity Sika Concrete Primer Two -component, solvent -based polyurethane primer applied at a rate of 225-375 ft /gal depending on substrate profile and porosity Cold applied, aliphatic, single component, moisture -triggered polyurethane resin Sikalastic 621 TC base and top coat applied with a 1/2-inch nap phenolic resin roller, spray, or squeegee applied Sikalastic 624 WP Cold applied, aliphatic, single component, alkali resistant moisture -triggered polyurethane base and top coat applied with a 1/2-inch nap phenolic resin roller, spray, or squeegee applied Liquid -Applied Waterproofing ASTM D 6083, Type I, cold applied, aliphatic, single component, moisture- Sikalastic 641 Lo-VOC triggered polyurethane base and top coat applied with a 1/2-inch nap phenolic resin roller, spray, or squeegee applied Sika Fleece 120 Non -woven, needle -punched polyester fleece reinforcement; Min. 3-inch side laps Sika Fleece 140 and min. 6-inch end laps; Embed into wet resin and apply wet roller to top to Reinforcement saturate Sika Fleece 170 Sika Reemat Premium Surface treated, randomly oriented glass fiber reinforcement; Min. 2-inch overlapping seams; Embed into wet resin and apply wet roller to top to saturate Laticrete 254 Platinum Thin -Set Mortar Overburden Attachment Applied with 1/4" x 3/8" x 1/4" notched trowel MAPEI Ceramic Tile Mortar Versabond Fortified Thin -Set Mortar WATERPROOFING SYSTEMS System Component Detail with Sika Reemat Reinforcement Detail with Sika Fleece Reinforcement Sikalastic 621 TC Base Coat: 2 applied at a rate of 35 ft /gal I Reinforcement: Sika Reemat Premium Roof Pro 20 I TC System Sikalastic 621 TC applied at a rate of 53 ft2/gal with silica Top Coat: sand broadcast at a rate of 2.75 Ibs/100 ftZ into wet top coat SIKA14001.4 FL17440-R4 Page 2 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK SIKCORPORATION Sikalastic RoofPro Roofing and Waterpp roofing Systems TECHNICAL SERVICES, LLC System Component Detail with Sika Reemat Reinforcement Detail with Sika Fleece Reinforcement Base Coat: Sikalastic 621 TC applied at a rate of 35 ft2/gal Reinforcement: Sika Reemat Premium Roof Pro 25 TC System Intermediate Coat: Sikalastic 621 TC applied at a rate of 53 ft2/gal Sikalastic 621 TC Top Coat: applied at a rate of 53 ft2/gal with silica sand broadcast at a rate of 2.75 Ibs/100 ft2 into wet top coat EL Base Coat: Sikalastic 624 WP 2 applied at a rate of 35 ft /gal Sikalastic 624 WP 2 applied at a rate of 32 ft2 /gal Reinforcement: Sika Reemat Premium Sika Fleece 140 Roof Pro 20 WP System Intermediate Coat: Sikalastic 624 WP applied at a rate of 40 ft2/gal Sikalastic 624 WP applied at a rate of 45 ft2/gal Top Coat: Sikalastic 624 WP applied at a rate of 107 ft2/gal with silica sand broadcast at a rate of 50 Ibs/100 ft2 into wet top coat Base Coat: Sikalastic 624 WP 2 applied at a rate of 35 ft /gal Sikalastic 624 WP 2 applied at a rate of 24 ft /gal Reinforcement: Sika Reemat Premium Sika Fleece 170 RoofPro 25 WP System Intermediate Coat: Two (2) coats of Sikalastic 624 WP applied at a rate of 53 ft2/gal. Allow 12 hours cure time between first and second coat. Sikalastic 624 WP applied at a rate of 40 ft2/gal 7TOPSikalastic Coat: 624 WP applied at a rate of 107 ft2/gal with silica sand broadcast at a rate of 50 Ibs/100 ft2 into wet top coat 641 Lo-VOC Base Coat: Sikalastic 641 Lo-VOC 2 applied at a rate of 32 ft /gal Sikalastic 641 Lo-VOC 2 applied at a rate of 35 ft /gal Reinforcement: Sika Reemat Premium Sika Fleece 120 Roof Pro 15 System Top Coat: Sikalastic 641 Lo-VOC applied at a rate of 80 ft2/gal Sikalastic 641 Lo-VOC applied at a rate of 64 ft2/gal 641 Lo-VOC Base Coat: Sikalastic 641 Lo-VOC 2 applied at a rate of 32 ft2/gal Sikalastic 641 Lo-VOC 2 applied at a rate of 32 ft /gal Reinforcement: Sika Reemat Premium Sika Fleece 140 Roof Pro 20 System Top Coat: Sikalastic 641 Lo-VOC applied at a rate of 53 ft2/gal Sikalastic 641 Lo-VOC applied at a rate of 53 ft2/gal Base Coat: Sikalastic 641 Lo-VOC 2 applied at a rate of 32 ft /gal Sikalastic 641 Lo-VOC 2 applied at a rate of 24 ft /gal 641 Lo-VOC Reinforcement: Sika Reemat Premium Sika Fleece 170 Roof Pro 25 Top Coat: Two (2) coats of Sikalastic 641 Lo-VOC applied at a rate of 69 ft2/gal. Allow 12 hours cure time between first and second Sikalastic 641 Lo-VOC applied at a rate of 47 ft2/gal System coat. SIKA14001.4 FL17440-R4 Page 3 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC APPROVED ASSEMBLIES SIKA CORPORATION Sikalastic RoofPro Roofing and Waterproofing Systems The following notes shall be observed when using the waterproofing systems from the tables below. 1. Maximum Design Pressures were calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS section of this evaluation when using the table(s) below. 3. Refer to PRODUCT DESCRIPTION & APPLICATION section of this report for installation detail when the information is not explicitly stated for the selected roof system. 4. The on -center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system. Assemblies with Adhered Membranes over Concrete Deck (New or Existing) Max. SyNttem Deck Detail Watero.proofing System Overburden DesiPressgn re (psf) Min 2500 psi concrete primed Minimum 2500 psi, C-1 with Sika Bonding Primer, Sikalastic DTE Primer, RoofPro 20 WP System 2-inch thick -367.5 Sikalastic EP Primer/Sealer, or or RoofPro 25 WP System structural concrete (Lim. 9) Sika Concrete Primer Lo-VOC poured in place Minimum 12" x 12" tiles complying with Min 2500 psi concrete primed ANSI A137.1 secured in with Sika Bonding Primer, 20 WP System Laticrete 254 Platinum 495 C-2 Sikalastic DTE Primer, r RofPro or RoofPro 25 WP System thin -set mortar, (Lim. 9) Sikalastic EP Primer/Sealer, or Versabond Fortified Sika Concrete Primer Lo-VOC Thin -Set Mortar, or MAPEI Ceramic Tile Mortar RoofPro 20 TC System, Min 2500 psi concrete primed RoofPro 25 TC System, with Sika Bonding Primer, RoofPro 20 WP System, Drainage medium C-3 Sikalastic DTE Primer, RoofPro 25 WP System followed by -502.5 Sikalastic EP Primer/Sealer, or (without top coat), min. 24-inch (Lim. 9) Sika Concrete Primer Lo-VOC 641 Lo-VOC RoofPro 15 System, deep soil medium 641 Lo-VOC RoofPro 20 System or 641 Lo-VOC RoofPro 25 System Min 2500 psi concrete primed RoofPro 20 TC System, with Sika Bonding Primer, Sikalastic DTE Primer, RoofPro 25 TC System, -502.5 C-4 Sikalastic EP Primer/Sealer, 641 Lo-VOC RoofPro 15 System, (Lim. 9) Sika Concrete Primer, or 641 Lo-VOC RoofPro 20 System or Sika Concrete Primer Lo-VOC 641 Lo-VOC RoofPro 25 System SIKA14001.4 FL17440-R4 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 G R E E SIKA CORPORATION Sikalastic RoofPro Roofing and Waterproofing Systems TECHNICAL SERVICES, LLC LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. The roof deck and the roof deck attachment information are provided based on testing. FBC requirements for the rational design of the roof deck, including the attachment, are not within the scope of this evaluation. 3. Foam plastic insulation shall be installed in accordance with the FBC Section 2603.4.1.5 and 2603.6. 4. In the HVHZ, fastener spacing for insulation attachment is determined using a Minimum Characteristic Force (F') of 275 Ibf as demonstrated via testing to TAS 105. If the field tested fastener value is below 275 Ibf, then insulation attachment shall not be acceptable. 5. In the HVHZ, fastener spacing for base sheets or membrane attachment shall meet the minimum fastener resistance value and the MDP for the specified roof system. It is permissible for a qualified professional to submit a revised fastener spacing utilizing the withdrawal resistance value obtained from TAS 105 testing and calculations performed in accordance with RAS 117 and/or RAS 137, when the fastener resistance is found less than required. 6. In the HVHZ, if mechanical attachment through the lightweight insulating concrete to the structural deck is proposed, a field fastener withdrawal test shall be conducted in compliance with TAS 105 to determine equivalent or increased attachment densities. Revised fastener densities shall be submitted utilizing the withdrawal resistance value obtained from TAS 105 testing and calculations performed in accordance with RAS 117 and/or RAS 137. 7. For assemblies containing mechanical attachment, the allowable uplift pressure for the selected roof system shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16. For perimeter and corner roof zones 2 and 3, the attachment density may be increased by a qualified design professional, as necessary, to meet the design pressure requirements in these areas. In the HVHZ, calculations shall be conducted in compliance with RAS 117 and/or RAS 137. Outside the HVHZ, commonly used standards include RAS 117, FM LPDS 1-29, or ANSI/SPRI WD-1. 8. Reroofing applications shall be examined in accordance with FBC Section 1511 outside of the HVHZ and FBC Section 1521 within the HVHZ. For mechanically fastened systems, a field withdrawal resistance test (TAS 105 in the HVHZ; ANSI/SPRI FX-1 or TAS 105 in the non-HVHZ) shall be conducted by a qualified professional to ensure the fastener meets the minimum design load requirements of the system. For adhered systems, a field uplift resistance test (TAS 124 in the HVHZ; ASTM E 907, FM LPDS 1-52, ANSI/SPRI IA-1, or TAS 124 in the non-HVHZ) shall be conducted to confirm conformance of the existing to the minimum design loads. 9. For assemblies containing fully adhered or ribbon adhered attachment, or where extrapolation of the roof system is not permitted, the MDP for the selected roof system shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16 without augmentation. 10. Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 11. The minimum roof slope shall be 1/4:12 for new construction. 12. The AHJ may require integrity flood testing (ASTM D 5957) or Electric Field Vector Mapping tests of all waterproofing systems prior to placement of the overburden material. Testing, if required, should be conducted by a qualified design professional. In the HVHZ, the waterproofing system shall be flood tested in accordance with Section 1519.16.6. 13. All products listed in this report shall be manufactured under a quality assurance programs in compliance with Rule 61G20-3. SIKA14001.4 FL17440-R4 Page 5 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 G R E E SIKA CORPORATION Sikalastic RoofPro Roofing and Waterproofing Systems TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 71" Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. P11Y1 iR „p,����i No 74021 O:. STATE OF :�4/ CERTIFICATION OF INDEPENDENCE 2020.08.09 16:38:26 -04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT SIKA14001.4 FL17440-R4 Page 6 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 04 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION GAF Evaluation Report 01506.09.05-1147 1 Campus Drive FL5293-R46 Parsippany, NJ 07054 Date of Issuance: 11/09/2005 (800) 766-3411 Revision 47: 06/07/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7t' Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: EverGuardO TPO Single -Ply Roof Membrane Systems for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEW ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 156-page Appendix. Prepared by: Robert J.M. Nieminen � P.E. °� ` ` �' r p The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983�"n � a ""'vC'Nieminen, P.E. on 06/07/2021. This does not serve as an t electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC ONEMOletc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Single Ply Roof Systems Compliance Statement: EverGuard® TPO Single -Ply Roof Membrane Systems, as produced by GAF, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.6 Physical properties ASTM G155 2013 1504.7 Impact resistance FM 4470 2016 1507.10.2 Material standard ASTM D2178 2015 1507.10.2 Material standard ASTM D4601 2012 1507.10.2 Material standard ASTM D4897 2009 1507.11.2 Material standard ASTM D6163 2015 1507.11.2 Material standard ASTM D6164 2011 1507.13.2 Material standard ASTM D6878 2013 Entity Exam Reference Date Entity Exam Reference Date ACRC (TST4671) TAS 114 06-035 10/18/2006 FM App (TST1867) FM 4474 3056207 02/09/2016 ACRC (TST4671) TAS 114 07-005 01/17/2007 FM App (TST1867) FM 4474 3055167 02/10/2016 ACRC (TST4671) TAS 114 07-024 03/01/2007 FM App (TST1867) FM 4474 RR204005 04/13/2016 ACRC (TST4671) TAS 114 07-016 04/19/2007 FM App (TST1867) FM 4474 RR205159 05/05/2016 ACRC (TST4671) TAS 114 07-017 04/19/2007 FM App (TST1867) FM 4474 RR205192 05/09/2016 ACRC (TST4671) TAS 114 07-025 05/02/2007 FM App (TST1867) FM 4474 RR205233 06/15/2016 ACRC (TST4671) TAS 114 07-026 05/03/2007 FM App (TST1867) FM 4474 RR205846 07/21/2016 ACRC (TST4671) TAS 114 07-027 05/04/2007 FM App (TST1867) FM 4474 RR20S474 08/31/2016 ACRC (TST4671) TAS 114 07-042 08/31/2007 FM App (TST1867) FM 4474 RR206198 09/01/2016 ACRC (TST4671) TAS 114 07-043 09/05/2007 FM App (TST1867) FM 4474 RR206353 09/07/2016 ACRC (TST4671) TAS 114 07-045 09/06/2007 FM App (TST1867) FM 4474 RR206620 09/12/2016 ACRC (TST4671) TAS 114 07-046 09/06/2007 FM App (TST1867) FM 4474 RR206351 10/21/2016 ACRC (TST4671) TAS 114 07-048 09/07/2007 FM App (TST1867) FM 4474 3055491 12/05/2016 ACRC (TST4671) TAS 114 07-049 09/10/2007 FM App (TST1867) FM 4474 3058483 12/09/2016 ACRC (TST4671) TAS 114 07-080 01/03/2008 FM App (TST1867) FM 4474 3056728LTR 12/23/2016 ACRC (TST4671) TAS 114 08-022 04/17/2008 FM App (TST1867) FM 4470 3056822 LTR 01/04/2017 ACRC (TST4671) TAS 114 08-030 04/05/2008 FM App (TST1867) FM 4474 RR208456 02/13/2017 ACRC (TST4671) TAS 114 08-023 04/17/2008 FM App (TST1867) FM 4474 3061218 05/10/2017 ACRC (TST4671) TAS 114 08-033 04/19/2008 FM App (TST1867) FM 4474 3061218LTR 05/16/2017 ACRC (TST4671) TAS 114 08-032 04/19/2008 FM App (TST1867) FM 4474 RR209927 06/23/2017 ACRC (TST4671) TAS 114 11-004 03/21/2011 FM App (TST1867) FM 4474 RR210305 07/13/2017 ACRC (TST4671) TAS 114 11-011 03/24/2011 FM App (TST1867) FM 4474 RR213506 03/28/2018 ACRC (TST4671) TAS 114 11-012 04/06/2011 FM App (TST1867) FM 4474 RR212730 04/05/2018 ACRC (TST4671) TAS 114 11-013 04/06/2011 FM App (TST1867) FM 4474 PR449797 04/24/2018 ACRC (TST4671) TAS 114 11-019 04/08/2011 FM App (TST1867) FM 4474 RR213333 04/25/2018 ACRC (TST4671) TAS 114 11-020 04/08/2011 FM App (TST1867) FM 4474 3056933 07/19/2018 ACRC (TST4671) TAS 114 11-021 04/11/2011 FM App (TST1867) FM 4474 3061784 07/25/2018 ACRC (TST4671) TAS 114 11-040 08/05/2011 FM App (TST1867) FM 4474 RR215107-267 09/27/2018 ACRC (TST4671) TAS 114 11-041 08/05/2011 FM App (TST1867) FM 4474 3055904 10/25/2018 ACRC (TST4671) TAS 114 11-056 09/30/2011 FM App (TST1867) FM 4474 RR215191-267 11/07/2018 ACRC (TST4671) TAS 114 12-008 04/10/2012 FM App (TST1867) FM 4474 RR215193-267 11/08/2018 ACRC (TST4671) TAS 114 12-012 04/23/2012 FM App (TST1867) FM 4474 RR217564-267 02/05/2019 ACRC (TST4671) TAS 114 12-013 04/23/2012 FM App (TST1867) FM 4474 PR453601-R1 11/15/2019 ACRC (TST4671) TAS 114 12-014 04/23/2012 FM App (TST1867) Criticality PR452423 02/06/2020 ACRC (TST4671) TAS 114 12-016 04/24/2012 FM App (TST1867) FM 4474 RR221253-267 02/07/2020 ACRC (TST4671) TAS 114 12-019 04/25/2012 FM App (TST1867) Criticality PR452971 02/19/2020 ACRC (TST4671) TAS 114 12-024 05/09/2012 FM App (TST1867) FM 4474 RR222755-267 03/10/2020 ACRC (TST4671) TAS 114 12-025 05/09/2012 FM App (TST1867) FM 4474 PR450754 04/03/2020 ACRC (TST4671) TAS 114 12-029 05/23/2012 FM App (TST1867) FM 4474 PR455417 09/30/2020 ACRC (TST4671) TAS 114 12-030 05/23/2012 FM App (TST1867) FM 4474 PR455417 R2 12/23/2020 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5293-R46 GAF EverGuard® TPO Single -Ply Roof Membrane Systems Revision 47: 06/07/2021 Page 2 of 6 *NEMO I etc. Entity Exam Reference Date Entity Exam Reference Date ACRC(TST4671) TAS 114 11-042-R1 01/27/2012 FM App (TST1867) FM 4474 RR227079 03/10/2021 ACRC(TST4671) TAS 114 12-033 08/10/2012 FM App (TST1867) Traceability PR459034 03/24/2021 ACRC(TST4671) TAS 114 12-036 08/13/2012 FM App (TST1867) FM 4474 PR458073 04/08/2021 ACRC(TST4671) TAS 114 12-018-R1 01/30/2013 Intertek(TST1558) TAS 114 G9819.01-109-44 08/15/2017 ACRC(TST4671) TAS 114 08-022-R1 01/15/2015 IRT(TST7408) TAS 114 02-008 01/18/2002 ACRC(TST4671) TAS 114 11-056-112 01/23/2015 IRT(TST7408) TAS 114 03-0728 02/17/2004 ACRC(TST4671) TAS 114 16-002 03/04/2016 IRT(TST7408) TAS 114 04-012 02/18/2004 ACRC(TST4671) TAS 114(D) 20-016 11/11/2020 IRT(TST7408) TAS 114 04-019 04/26/2004 ACRC(TST4671) TAS 114(D) 20-017 11/11/2020 NEMO (TST6049) FM 4474 SC16825.12.17-3A 01/01/2018 ACRC (TST4671) TAS 114(D) 20-019 11/13/2020 NEMO (TST6049) Physicals 4q-GAF-I9-SSMBB-03.A 05/13/2019 ACRC(TST4671) TAS 114(D) 20-021 11/13/2020 PRI (TST5878) ASTM C1289 GAF-373-02-01 10/15/2012 ACRC(TST4671) TAS 114(D) 20-022 11/16/2020 PRI (TST5878) FM 4474 GAF-043-02-03 09/16/2013 ACRC(TST4671) TAS 114(D) 20-023 11/16/2020 PRI (TST5878) FM 4474 GAF-043-02-04 09/16/2013 ACRC(TST4671) TAS 114(1) 21-006 03/16/2021 PRI (TST5878) ASTM D6878 GAF-423-02-01 10/21/2013 ATI(TST1558) TAS 114 H-3320.01-109-44 08/10/2017 PRI (TST5878) ASTM D6878 GAF-421-02-01 10/22/2013 ATI(TST1558) TAS 114 H-3314.01-109-44 08/14/2017 PRI(TST5878) ASTM D6878 GAF-422-02-01 10/22/2013 ATI(TST1558) TAS 114 H-3315.01-109-44 08/14/2017 PRI (TST5878) ASTM D6878 GAF-424-02-01 11/11/2013 ATI(TST1558) TAS 114 H-3317.01-309-44 08/14/2017 PRI (TST5878) ASTM D6878 GAF-425-02-01 11/11/2013 ATI (TST1558) TAS 114 H-3318.01-109-44 08/14/2017 PRI (TST5878) Criticality GAF-462-02-02 11/18/2013 ATI(TST1558) TAS 114 H-0730.01-109-44 08/16/2017 PRI (TST5878) FM 4474 GAF-457-02-02 01/20/2014 ERD(TST6049) TAS 114 SC8580.11.15-4 11/09/2015 PRI (TST5878) FM 4474 GAF-457-02-04 01/24/2014 ERD(TST6049) FM 4474 SC8580.11.15-2 11/18/2015 PRI (TST5878) FM 4474 GAF-457-02-06 01/24/2014 ERD(TST6049) Criticality SC16505.17 09/22/2017 PRI (TST5878) FM 4474 GAF-457-02-07 01/24/2014 ERD(TST6049) FM 4474 SC16825.12.17-1 12/31/2017 PRI (TST5878) FM 4474 GAF-457-02-08 01/24/2014 ERD (TST6049) FM 4474 SC16825.12.17-3B 12/31/2017 PRI(TST5878) Rupture GAF-435-02-01 01/29/2014 F-TEC(TST7393) TAS 114 08-050183 06/26/2008 PRI (TST5878) FM 4474 GAF-435-02-07 01/29/2014 F-TEC(TST7393) TAS 114 08-050184 06/26/2008 PRI (TST5878) FM 4474 GAF-435-02-08 01/29/2014 F-TEC(TST7393) TAS 114 08-070133 08/04/2008 PRI (TST5878) FM 4474 GAF-435-02-09 01/29/2014 F-TEC(TST7393) TAS 114 08-050185 10/14/2008 PRI (TST5878) FM 4474 GAF-435-02-10 01/29/2014 F-TEC(TST7393) TAS 114 08-072805 02/16/2009 PRI (TST5878) FM 4474 GAF-435-02-11 01/29/2014 FM App (TST1867) FM 4470 3003617 12/20/1999 PRI (TST5878) FM 4474 GAF-506-02-06 03/06/2014 FM App (TST1867) FM 4470 3009026 06/18/2002 PRI (TST5878) FM 4474 GAF-506-02-08 03/06/2014 FM App (TST1867) FM 4470 3013861 03/28/2003 PRI (TST5878) FM 4474 GAF-506-02-10 03/06/2014 FM App (TST1867) FM 4470 3014692 08/05/2003 PRI (TST5878) FM 4474 GAF-510-02-02 04/08/2014 FM App (TST1867) FM 4470 3014955 01/22/2004 PRI (TST5878) FM 4474 GAF-510-02-04 04/08/2014 FM App (TST1867) FM 4470 3012721 02/11/2004 PRI (TST5878) FM 4474 GAF-510-02-05 04/08/2014 FM App (TST1867) FM 4470 3015029 02/19/2004 PRI (TST5878) FM 4474 GAF-511-02-02 04/08/2014 FM App (TST1867) FM 4470 3015578 03/12/2004 PRI (TST5878) FM 4474 GAF-506-02-11 04/14/2014 FM App (TST1867) FM 4470 3020588 03/24/2004 PRI (TST5878) FM 4474 GAF-506-02-12 04/14/2014 FM App (TST1867) FM 4470 3019881 03/20/2004 PRI (TST5878) FM 4474 GAF-506-02-13 04/14/2014 FM App (TST1867) FM 4470 3016068 04/02/2004 PRI (TST5878) FM 4474 GAF-506-02-14 04/14/2014 FM App (TST1867) FM 4470 3013861 05/21/2004 PRI (TST5878) FM 4474 GAF-506-02-01 04/22/2014 FM App (TST1867) FM 4470 3105578 05/12/2004 PRI (TST5878) FM 4474 GAF-514-02-01 05/12/2014 FM App (TST1867) FM 4470 3014955 01/28/2005 PRI (TST5878) FM 4474 GAF-514-02-03 05/12/2014 FM App (TST1867) FM 4470 3022136 03/17/2005 PRI (TST5878) FM 4474 GAF-514-02-04 05/12/2014 FM App (TST1867) FM 4470 3020681 09/01/2005 PRI (TST5878) FM 4474 GAF-514-02-05 05/12/2014 FM App (TST1867) FM 4470 3024051 03/28/2006 PRI (TST5878) FM 4474 GAF-514-02-07 05/12/2014 FM App (TST1867) FM 4470 797-02093-267 04/26/2006 PRI (TST5878) FM 4474 GAF-514-02-08 05/12/2014 FM App (TST1867) FM 4470 3023458 07/18/2006 PRI (TST5878) FM 4474 GAF-516-02-01 05/13/2014 FM App (TST1867) FM 4470 3028039 09/11/2006 PRI (TST5878) FM 4474 GAF-516-02-03 05/13/2014 FM App (TST1867) FM 4470 3027159 10/03/2006 PRI (TST5878) FM 4474 GAF-516-02-02 06/06/2014 FM App (TST1867) FM 4470 3026149 02/05/2007 PRI (TST5878) FM 4474 GAF-525-02-02 06/23/2014 FM App (TST1867) FM 4470 3026964 07/25/2007 PRI (TST5878) FM 4474 GAF-525-02-03 06/23/2014 FM App (TST1867) FM 4470 3028857 11/02/2007 PRI (TST5878) FM 4474 GAF-462-02-09 07/01/2014 FM App (TST1867) FM 4470 3030199 11/05/2007 PRI (TST5878) FM 4474 GAF-462-02-10 07/01/2014 FM App (TST1867) FM 4470 3030813 11/05/2007 PRI (TST5878) FM 4474 GAF-462-02-11 07/01/2014 FM App (TST1867) FM 4470 3031262 11/30/2007 PRI (TST5878) FM 4474 GAF-524-02-02 07/01/2014 FM App (TST1867) FM 4470 3030292 02/25/2008 PRI (TST5878) FM 4474 GAF-524-02-03 07/01/2014 FM App (TST1867) FM 4470 797-03825-267 07/21/2008 PRI (TST5878) FM 4474 GAF-524-02-05 07/01/2014 FM App (TST1867) FM 4470 3033314 08/26/2008 PRI (TST5878) FM 4474 GAF-540-02-02 08/06/2014 FM App (TST1867) FM 4470 3034749 10/16/2008 PRI (TST5878) FM 4474 GAF-540-02-03 08/06/2014 FM App (TST1867) FM 4470 3032856 11/24/2008 PRI (TST5878) FM 4474 GAF-540-02-04 08/06/2014 FM App (TST1867) FM 4470 3033135 11/24/2008 PRI (TST5878) FM 4474 GAF-538-02-02 08/13/2014 FM App (TST1867) FM 4470 3033862 12/24/2008 PRI (TST5878) FM 4474 GAF-538-02-03 08/13/2014 FM App (TST1867) FM 4470 3034394 02/27/2009 PRI (TST5878) FM 4474 GAF-532-02-01 08/22/2014 FM App (TST1867) FM 4470 3033121 04/13/2009 PRI (TST5878) FM 4474 GAF-524-02-05 08/27/2014 FM App (TST1867) FM 4470 3035300 05/06/2009 PRI (TST5878) FM 4474 GAF-549-02-01 08/08/2014 FM App (TST1867) FM 4470 3036614 06/09/2009 PRI (TST5878) FM 4474 GAF-538-02-04 09/02/2014 FM App (TST1867) FM 4470 3034310 06/15/2009 PRI (TST5878) FM 4474 GAF-559-02-11 10/16/2014 FM App (TST1867) FM 4470 3036141 08/10/2009 PRI (TST5878) FM 4474 GAF-559-02-12 10/16/2014 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5293-11146 GAF EverGuard® TPO Single -Ply Roof Membrane Systems Revision 47: 06/07/2021 Page 3 of 6 *NEMO I etc. Entity Exam Reference Date Entity Exam Reference Date FM App (TST1867) FM 4470 3037820 04/30/2010 PRI (TST5878) FM 4474 GAF-559-02-13 10/16/2014 FM App (TST1867) FM 4470 797-059797-267 08/18/2010 PRI(TST5878) FM 4474 GAF-559-02-14 10/16/2014 FM App (TST1867) FM 4470 3038215 09/02/2010 PRI(TST5878) FM 4474 GAF-559-02-15 10/16/2014 FM App (TST1867) FM 4470 797-05901-267 10/01/2010 PRI(TST5878) FM 4474 GAF-559-02-16 10/16/2014 FM App (TST1867) FM 4470 797-06003-267 11/11/2010 PRI(TST5878) FM 4474 GAF-559-02-18 10/16/2014 FM App (TST1867) FM 4470 3038318 12/10/2010 PRI(TST5878) FM 4474 GAF-538-02-05 12/03/2014 FM App (TST1867) FM 4470 797-06178-267 02/07/2011 PRI(TST5878) ASTM D6878 GAF-584-02-01 11/20/2015 FM App (TST1867) FM 4470 3040234 02/23/2011 PRI(TST5878) ASTM D6878 GAF-585-02-01 11/20/2015 FM App (TST1867) FM 4470 3040377 03/08/2011 PRI(TST5878) ASTM D6878 GAF-586-02-01 11/20/2015 FM App (TST1867) FM 4470 3041685 03/24/2011 PRI (TST5878) FM 4474 GAF-453-02-05 05/06/2016 FM App (TST1867) FM 4470 797-06254-267 03/24/2011 PRI(TST5878) FM 4474 GAF-453-02-09 05/06/2016 FM App (TST1867) FM 4470 3041535 06/08/2011 PRI (TST5878) Criticality GAF-653-02-01 10/20/2016 FM App (TST1867) FM 4470 797-06537-267 06/13/2011 PRI(TST5878) FM 4474 GAF-653-02-04 10/20/2016 FM App (TST1867) FM 4470 797-06538-267 06/13/2011 PRI(TST5878) FM 4474 GAF-746-02-01 12/14/2016 FM App (TST1867) FM 4470 3041746 08/17/2011 PRI(TST5878) FM 4474 GAF-746-02-02 12/14/2016 FM App (TST1867) FM 4470 797-06894-267 11/02/2011 PRI(TST5878) FM 4474 GAF-746-02-05 12/14/2016 FM App (TST1867) FM 4470 3038278 11/18/2011 PRI(TST5878) FM 4474 GAF-746-02-06 12/14/2016 FM App (TST1867) FM 4470 3042905 01/10/2012 PRI (TST5878) FM 4470 GAF-755-02-01 02/02/2017 FM App (TST1867) FM 4470 797-07041-267 02/27/2012 PRI(TST5878) FM 4474 GAF-755-02-02 02/02/2017 FM App (TST1867) FM 4470 797-07183-267 03/01/2012 PRI(TST5878) FM 4474 GAF-755-02-03 02/02/2017 FM App (TST1867) FM 4470 3044506 03/28/2012 PRI(TST5878) FM 4474 GAF-755-02-04 02/02/2017 FM App (TST1867) FM 4470 797-07331-267 04/13/2012 PRI(TST5878) ASTM D6878 GAF-700-02-01 03/10/2017 FM App (TST1867) FM 4470 3044862 05/11/2012 PRI(TST5878) ASTM D2178 MSA-039-02-01 09/27/2017 FM App (TST1867) FM 4470 797-07455-267 05/31/2012 PRI(TST5878) ASTM D2178 MSA-039-02-02 09/27/2017 FM App (TST1867) FM 4470 797-07474-267 06/11/2012 PRI(TST5878) FM 4474 GAF-782-02-01 08/24/2017 FM App (TST1867) FM 4470 797-07476-267 06/21/2012 PRI(TST5878) FM 4474 GAF-782-02-02 08/30/2017 FM App (TST1867) FM 4470 3045789 07/12/2012 PRI(TST5878) FM 4474 GAF-776-02-02 10/04/2017 FM App (TST1867) FM 4470 3045166 07/24/2012 PRI (TST5878) Criticality GAF-793-02-01 12/08/2017 FM App (TST1867) FM 4470 3045863 08/16/2012 PRI(TST5878) FM 4474 GAF-793-02-02 12/08/2017 FM App (TST1867) FM 4470 3041749 08/23/2012 PRI(TST5878) FM 4474 GAF-793-02-04 12/08/2017 FM App (TST1867) FM 4470 3046328 09/13/2012 PRI (TST5878) FM 4474 GAF-835-02-02 02/19/2018 FM App (TST1867) FM 4470 3041769 09/27/2012 PRI(TST5878) FM 4474 GAF-834-02-01 02/28/2018 FM App (TST1867) FM 4470 797-07744-267 10/17/2012 PRI(TST5878) FM 4474 GAF-835-02-03 02/28/2018 FM App (TST1867) FM 4470 797-07885-267 11/21/2012 PRI(TST5878) FM 4474 GAF-835-02-04 02/28/2018 FM App (TST1867) FM 4470 3046054 12/21/2012 PRI(TST5878) FM 4474 GAF-833-02-01 03/02/2018 FM App (TST1867) FM 4470 797-08216-267 04/11/2013 PRI(TST5878) FM 4474 GAF-833-02-02 03/02/2018 FM App (TST1867) FM 4470 3048122 04/29/2013 PRI(TST5878) FM 4474 GAF-836-02-01 03/02/2018 FM App (TST1867) FM 4470 797-08217-267 05/01/2013 PRI(TST5878) FM 4474 GAF-836-02-02 03/02/2018 FM App (TST1867) FM 4470 797-08264-267 05/23/2013 PRI(TST5878) FM 4474 GAF-836-02-03 03/02/2018 FM App (TST1867) FM 4470 3047237 07/15/2013 PRI(TST5878) FM 4474 GAF-836-02-04 03/02/2018 FM App (TST1867) FM 4470 3047636 08/08/2013 PRI(TST5878) FM 4474 GAF-858-02-05 04/27/2018 FM App (TST1867) FM 4474 797-08873-267 11/26/2013 PRI(TST5878) FM 4474 GAF-858-02-01 05/01/2018 FM App (TST1867) FM 4474 3048066 12/13/2013 PRI(TST5878) FM 4474 GAF-858-02-02 05/01/2018 FM App (TST1867) FM 4474 3041749 12/30/2013 PRI(TST5878) FM 4474 GAF-858-02-03 05/01/2018 FM App (TST1867) FM 4474 797-09116-267 01/24/2014 PRI(TST5878) FM 4474 GAF-858-02-04 05/01/2018 FM App (TST1867) FM 4474 797-09234-267 03/11/2014 PRI(TST5878) FM 4474 GAF-858-02-06 05/01/2018 FM App (TST1867) FM 4474 797-09317-267 04/18/2014 PRI(TST5878) FM 4474 GAF-834-02-03 05/11/2018 FM App (TST1867) FM 4474 797-09493-267 05/27/2014 PRI(TST5878) ASTM D6878 GAF-870-02-01 02/15/2019 FM App (TST1867) FM 4474 797-09495-267 05/27/2014 PRI(TST5878) FM 4474 GAF-902-02-02 02/27/2019 FM App (TST1867) FM 4474 797-09573-267 06/13/2014 PRI(TST5878) FM 4474 GAF-926-02-02 07/17/2019 FM App (TST1867) FM 4474 797-09497-267 06/23/2014 PRI(TST5878) FM 4474 376T0014 08/09/2019 FM App (TST1867) FM 4474 797-09594-267 06/24/2014 PRI(TST5878) FM 4474 376T0016 08/09/2019 FM App (TST1867) FM 4474 797-09635-267 07/16/2014 PRI(TST5878) FM 4474 376T0017 08/09/2019 FM App (TST1867) FM 4474 797-09892-267 10/30/2014 PRI(TST5878) FM 4474 376T0025 09/06/2019 FM App (TST1867) FM 4474 797-10123-283 12/17/2014 PRI(TST5878) FM 4474 376T0026 09/06/2019 FM App (TST1867) FM 4474 797-10153-267 12/19/2014 PRI(TST5878) Criticality 376T0006-1 01/18/2021 FM App (TST1867) FM 4474 797-10210-267 02/05/2015 PRI(TST5878) Criticality 376T0006-3 09/06/2019 FM App (TST1867) FM 4474 797-10211-267 02/05/2015 PRI(TST5878) FM 4474 376T0027 09/19/2019 FM App (TST1867) FM 4474 797-10212-267 02/05/2015 PRI(TST5878) ASTM D6878 GAF-904-02-01 10/09/2019 FM App (TST1867) FM 4474 797-RR20018 02/23/2015 PRI(TST5878) ASTM D6878 GAF-889-02-01 11/01/2019 FM App (TST1867) FM 4474 RR200320 04/07/2015 PRI(TST5878) FM 4474 376T0097 10/26/2020 FM App (TST1867) FM 4474 RR200321 04/07/2015 PRI(TST5878) FM 4474 376T0093 01/26/2021 FM App (TST1867) FM 4474 3055411 04/15/2015 PRI(TST5878) FM 4474 376T0098 01/26/2021 FM App (TST1867) FM 4474 3047636-LTR 06/24/2015 PRI(TST5878) FM 4474 376T0099 01/26/2021 FM App (TST1867) FM 4474 RR202913 11/19/2015 UL,LLC(QUA9625) QA Service confirmation 09/29/2020 FM App (TST1867) FM 4474 3053501 01/14/2016 UL,LLC(QUA9625) QA Florida BCIS Current NEMO ETC, LLC Evaluation Report 01506.09.05-R47 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5293-R46 GAF EverGuard® TPO Single -Ply Roof Membrane Systems Revision 47: 06/07/2021 Page 4 of 6 ONEMOletc. This Evaluation Report covers EverGuard' TPO Single -Ply Roof Membrane Systems installed in accordance with GAF published installation instructions and the Limitations / Conditions of Use herein. TABLE 1: EVALUATED MEMBRANES Type Product Material Standard Plant(s) Reference Type Grade EverGuard® TPO 45, 60, 80-mil ASTM D6878 N/A N/A IN, PA, TX, UT EverGuard Extreme' TPO 50, 60, 70, 80-mil ASTM D6878 N/A N/A IN, TX, UT Roof Cover or Cap Ply EverGuard° TPO Fleece -Back Membrane (formerly EverGuard° TPO FB Ultra) 45, 60, 80-mil ASTM D6878 N/A N/A IN, PA, UT EverGuard Extreme® TPO Fleece - Back Membrane (formerly EverGuard Extreme TPO FB Ultra) 50, 60, 70, 80-mil ASTM D6878 N/A N/A IN EverGuard® Freedom'" TPO HW 45, 60-mil ASTM D6878 N/A N/A IN GAFGLAS® #75 Base Sheet ASTM D4601 II N/A CA-F, GA Tri-Ply® #75 Base Sheet ASTM D4601 II N/A CA-F, GA Base Sheets GAFGLAS® #80 Ultima'"^ Base Sheet ASTM D4601 II N/A GA GAFGLAS® Stratavent® Nailable Venting Base Sheet ASTM D4897 II N/A CA-F, GA GAFGLAS® Ply 4 ASTM D2178 IV N/A CA-F, GA GAFGLAS® Ply 4 M ASTM D2178 IV N/A AL Ply Sheet GAFGLAS® FlexPly— 6 ASTM D2178 VI N/A CA-F, GA GAFGLAS® FlexPly— 6 M ASTM D2178 VI N/A AL Ruberoid° 20 Smooth ASTM D6163 I S AR, CA-S, GA Ruberoid° HW 25 Smooth ASTM D6163 I S GA Ruberoid° 30 Granule ASTM D6163 I G GA Base Ply or Ruberoid° HW Smooth ASTM D6164 I S GA Vapor Barrier Ruberoid® Mop Smooth ASTM D6164 I S CA-S, GA Membranes Ruberoid® Mop Smooth 1.5 ASTM D6164 I S CA-S, GA Ruberoid° Mop Plus Smooth ASTM D6164 II S CA-S Liberty'"" SBS Self -Adhering Cap Sheet ASTM D6164 I G AR, GA, IN Ruberoid° Torch Granule ASTM D6222 I G GA, IN 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements and limitations regarding edge securement for low -slope roofs. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5293-R46 GAF EverGuard® TPO Single -Ply Roof Membrane Systems Revision 47: 06/07/2021 Page 5 of 6 ONEMOletc. 5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations. 5.6.1 For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.6.2 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.6.3 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance. 5.7.1 "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 5.7.2 For mechanically attached components or partially -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 5.7.3 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. EverGuard° TPO Single -Ply Roof Membrane Systems shall be installed in accordance with GAF published installation instructions, subject to the Limitations / Conditions of Use noted herein. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL, LLC—QUA9625: (414) 248-6409, karen.buchmann@ul.com - THE 156-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 01506.09.05-R47 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5293-R46 GAF EverGuard® TPO Single -Ply Roof Membrane Systems Revision 47: 06/07/2021 Page 6 of 6 NNEMO I etc. TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 6 1B Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 7-11 1c Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 12-14 1D Wood New, Reroof (Tear -Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 14 1E Wood New, Reroof (Tear -Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 15-16 1F Wood New, Reroof (Tear -Off) or Recover C-2 Plate -Bonded Roof Cover 17-18 1G Wood New, Reroof (Tear -Off) or Recover D-1 Insulated, Mechanically Attached Roof Cover 18-19 1H Wood New, Reroof (Tear -Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 19 11 Wood New, Reroof (Tear -Off) or Recover E-1 Non -Insulated, Mechanically Attached Roof Cover 19-20 L Wood New, Reroof (Tear -Off) or Recover E-2 Non -Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 20-23 2A Steel New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 24 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 24-38 2c Steel or Structural concrete New, Reroof (Tear -Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Base and Cap Ply 38-40 2D Steel New or Reroof (Tear -Off) B-2 Mech. Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover 41-46 2E Steel or Structural concrete New, Reroof (Tear -Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 47-65 2F Steel or Structural concrete New, Reroof (Tear -Off) or Recover C-1 Mechanically Attached Insulation, Bonded Base and Cap Ply 65-67 2c Steel or Structural concrete New, Reroof (Tear -Off) or Recover C-1A Thermal Barrier with Vapor Barrier, Mechanically Attached Insulation, Bonded Roof Cover 67-72 2H Steel or Structural concrete New, Reroof (Tear -Off) or Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 73-75 21 Steel or Structural concrete New, Reroof (Tear -Off) or Recover D-1 Insulated, Mechanically Attached Roof Cover 75-81 2t Steel or Structural concrete New, Reroof (Tear -Off) or Recover D-2 Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 81 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 82-99 3B Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Base and Cap Ply 100-101 3c Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 101 4A Lightweight concrete / concrete New or Reroof (Tear -Off) A-1 LWC to Deck, Bonded Insulation, Bonded Roof Cover 102-106 4D Lightweight concrete / steel or concrete New or Reroof (Tear Off) E-2 LWC to Deck, Mechanically Attached Base Sheet, Bonded Roof Cover 109-110 4E Lightweight concrete / steel New or Reroof (Tear Off) F LWC to Deck, Bonded Roof Cover 111-112 4F Lightweight concrete / concrete New or Reroof (Tear Off) F LWC to Deck, Bonded Roof Cover 112-13 4c Lightweight concrete / concrete New or Reroof (Tear Off) F Temp Roof / Vapor Barrier to Deck, LWC to Temp Roof / Vapor Barrier, Bonded Roof Cover 114 5A Cementious wood fiber New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 115-116 5B Cementious wood fiber New, Reroof (Tear -Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 116 5c Cementious wood fiber New, Reroof (Tear -Off) or Recover E-2 Non -Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 116 5D Cementious wood fiber New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 116 6A Existing gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 117-118 6B Existing gypsum Reroof (Tear -Off) A-2 Mechanically Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 119 6c Existing gypsum Reroof (Tear -Off) B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 119-122 6D Existing gypsum Reroof (Tear -Off) C-1 Mechanically Attached Insulation, Bonded Roof Cover 122-123 6E Existing gypsum Reroof (Tear -Off) E-2 Non -Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 123 6F Existing gypsum Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 123 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 124-152 7B Wood or Steel Recover C-2 Plate -Bonded Roof Cover 153-154 7c Steel Recover D-1 Insulated, Mechanically Attached Roof Cover 154-155 7D Various Recover F Non -Insulated, Bonded Roof Cover 156 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7" Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 1 of 156 *NEMO I etc. The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec ASAP 3S, Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3" Metal Plate, Drill-Tec #12 DP Fastener or Drill-Tec#14 HD Fastener with Drill-Tec 3" Flat Steel Plate, Drill-Tec #12 DPH Fastener with Drill-Tec 3" Recessed Steel Plate, Drill-Tec 3" ASAP Flat or Drill-Tec 3" ASAP Recessed. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. ➢ Steel Deck: Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only); Drill-Tec ASAP 3S; Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3" Metal Plate; Drill-Tec Extra Heavy Duty ASAP Roofing Fastener - Insulation, Drill-Tec #12 DP Fastener, Drill-Tec #14 HD Fastener or Drill-Tec #15 EHD Fastener with Drill-Tec 3" Flat Steel Plate, Drill-Tec #12 DPH Fastener with Drill-Tec 3" Recessed Steel Plate, Drill-Tec 3" ASAP Flat or Drill-Tec 3" ASAP Recessed. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ➢ Structural Concrete: Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3" Metal Plate, Drill-Tec #14 HD Fastener with Drill-Tec 3" Flat Steel Plate or Drill-Tec 3" ASAP Flat (#14 only). Minimum 1- inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for, or installed below, rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non -wind -uplift -related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). 6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt: Full Coverage at 25-30lbs/square. If applying to concrete deck; deck shall be primed with ASTM D41 primer. ➢ GAF 2-Part Roofing Adhesive (GAF 2-Part): Continuous 2.5 to 3.5-inch ribbons, 12-inch o.c. ➢ GAF LRF Adhesive M (LRF-M): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ GAF LRF Adhesive XF (LRF-XF): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. using OMG PaceCart, SpotShot or Canister delivery methods. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7 Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to'increase'the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table. ➢ Hot asphalt: MDP = -240.0 psf (Min. 0.5-inch thick) ➢ GAF 2-Part: MDP = -117.5 psf (Min. 1.0-inch thick) ➢ LRF-M: MDP = -232.5 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation) ➢ LRF-XF or OB500: MDP = -292.5 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation) ➢ OB500: MDP = -315.0 psf (Min. 0.5-inch thick EnergyGuard RH or RN) ➢ LRF-XF or OB500: MDP = -487.5 psf (Min. 0.5-inch thick EnergyGuard RA) 8 For adhered roof insulation and board -size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 71^ Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 2 of 156 ONEMOJetc. 9 For mechanically attached components or partially -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard maybe used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent" LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Use of these listings in new construction or re -roof (tear -off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15 For bonded membrane applications, unless otherwise noted, refer to the following. MEMBRANE / ADHESIVE COMBINATIONS MEMBRANE ADHESIVE REFERENCE APPLICATION RATE EverGuard TPO EverGuard TPO #1121 Bonding #1121 Contact (both sides) 0.8 to 1.0 gal/square/surface. For use over SECUROCK Gypsum -Fiber Roof Board, the Adhesive application rate changes to 1.2 to 1.67 gal/sq/surface To polyisocya nu rate or Structodek High Density Fiberboard Roof Insulation, Fiber Base HDl or EverGuard TPO EverGuard WB181 Bonding WB181 Contact (both sides) Fiber Base HD6 at 0.63 gal/square and roof cover underside at 0.21 gal/square. To DensDeck Adhesive Prime or SECUROCK Gypsum -Fiber Roof Board at 0.63 to 0.75 gal/square and roof cover underside at 0.21 to 0.25 gal/square EverGuard TPO 6 Square Low VOC EverGuard TPO Bonding Adhesive (formerly EverGuard TPO 6-Square Contact (both sides) 0.46 gal/square/surface Low VOC TPO Bonding Adhesive) EverGuard TPO EverGuard TPO 3 Square Low VOC TPO 3-Square Contact (both sides) 0.84 gal/square/surface Bonding Adhesive EverGuard TPO EverGuard TPO Quick Spray TPO QSA Contact (both sides) Total application rate: -0.71 Ibs/sq (dry rate). Adhesive EverGuard TPO EverGuard TPO Quick Spray TPO QSA LV50 Contact (both sides) Total application rate: —0.84 lbs/sq (dry -rate). Adhesive LV 50 EverGuard TPO FastLayn TPO Adhesive FastLayn Wet lay (substrate) 0.4 gal/square EverGuard TPO Fleece- Hot asphalt Hot asphalt Wet lay (substrate) 25 Ibs/square Back Membrane NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 71h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 3 of 156 ONEMO I etc. MEMBRANE / ADHESIVE COMBINATIONS MEMBRANE ADHESIVE REFERENCE APPLICATION RATE EverGuard TPO Fleece- EverGuard WB181 Bonding Wg181 Wet lay (substrate) 0.83 to 1.0 gal/square Back Membrane Adhesive EverGuard TPO Fleece- 1-inch wide ribbons spaced as noted in tables herein. Note: The adhesive ribbons are located Back Membrane GAF LRF Adhesive M LRF-M Wet lay (substrate) directly over the adhesive ribbons used to secure the insulation when the cover is bonded to insulation less than 1.5-inch thick. EverGuard TPO Fleece- 1-inch wide ribbons spaced as noted in tables herein. Note: The adhesive ribbons are located Back Membrane GAF LRF Adhesive O LRF-O Wet lay (substrate) directly over the adhesive ribbons used to secure the insulation when the cover is bonded to insulation less than 1.5-inch thick. EverGuard TPO Fleece- GAF 2-Part Roofing Adhesive GAF 2-Part (spatter) Wet lay (substrate) "Spatter pattern" at 3.75 lbs/sq. Back Membrane EverGuard TPO Fleece - GAF LRF Adhesive XF LRF-XF (spatter) Wet lay (substrate) "Spatter pattern" at 3.0Ibs/sq. Back Membrane EverGuard TPO Fleece- "Spatter pattern" at 0.32 gal/square (to insulation or coverboard) Back Membrane OlyBond 500 Canister OB500 (spatter) Wet lay (substrate) "Spatter pattern" at 0.83 gal/square (to asphaltic base ply membrane). 15A For single -ply membranes in System Type D-1 steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes. 15B For System Type C-2 (induction weld), care shall be taken to ensure that the plates do not line-up with membrane seams. This condition may preclude proper induction welding of the membrane to the plates. 15C The'Triposite Roofing System" noted herein consists of loose -laid GAFGLAS Stratavent Perforated Venting Base Sheet, followed by asphalt -applied one (1) or two (2) plies of Ruberoid 20 Smooth or three (3) plies of GAFGLAS FlexPly 6 or GAFGLAS FlexPly 6 M, followed by asphalt -applied EverGuard TPO Fleece -Back Membrane with 1-5/8" heat welded side laps. 15D Unless otherwise noted, the "Hybrid Roofing System" noted herein consists of asphalt -applied Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet or GAFGLAS #80 Ultima Base Sheet followed by asphalt -applied EverGuard TPO Fleece -Back Membrane. 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs. those in Table 3A or 36 applies. VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE-APPUED INSULATION PER TABLE 3A OR 36 OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF) TYPE APPLICATION C-VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6 or GAFGLAS FlexPly 6 M Hot asphalt applied Hot asphalt -360.0 C-VB-2. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch -applied GAF 2-Part, 12-inch o.c. -169.0 C-VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch -applied GAF 2-Part, 12-inch o.c. -180.0 C-VB-4. GAF SA Primer GAF SA Vapor Retarder Self -adhering GAF 2-Part, 12-inch o.c. -202.5 C-VB-5. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self -Adhering Cap Sheet Self -adhering GAF 2-Part, 12-inch o.c. -250.0 C-VB-6. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6 or GAFGLAS FlexPly 6 M Hot asphalt applied GAF 2-Part, 12-inch o.c. -262.5 C-VB-7. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied GAF 2-Part, 12-inch o.c. -270.0 C-VB-8. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch -applied LRF-M, 12-inch o.c. -180.0 C-VB-9. GAF SA Primer GAF SA Vapor Retarder Self -adhering LRF-M, 12-inch o.c. -202.5 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 71h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 4 of 156 *NEMO I etc. VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE -APPLIED INSULATION PER TABLE 3A OR 3B OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF) TYPE APPLICATION C-VB-10. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6 or GAFGLAS FlexPly 6 M Hot asphalt applied LRF-M, 12-inch o.c. -495.0 C-VB-11. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch -applied LRF-XF, 12-inch o.c. -169.0 C-VB-12. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch -applied LRF-XF, 12-inch o.c. -180.0 C-VB-13. GAF SA Primer GAF SA Vapor Retarder Self -adhering LRF-XF, 12-inch o.c. -202.5 C-VB-14. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self -Adhering Cap Sheet Self -adhering LRF-XF, 12-inch o.c. -250.0 C-VB-15. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6 or GAFGLAS FlexPly 6 M Hot asphalt applied LRF-XF, 12-inch o.c. -262.5 C-VB-16. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied LRF-XF, 12-inch o.c. -270.0 C-VB-17. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Smooth Torch -applied OB500, 12-inch o.c. -165.0 C-VB-18. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth Torch -applied OB500, 12-inch o.c. -180.0 C-VB-19. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self -Adhering Cap Sheet Self -adhering OB500, 12-inch o.c. -187.5 C-VB-20. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 20 Smooth Matrix 102 SBS Membrane Adhesive at 1.5 gal/square OB500, 12-inch o.c. -202.5 C-VB-21. GAF SA Primer GAF SA Vapor Retarder Self -adhering OB500, 12-inch o.c. -202.5 C-VB-22. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch -applied OB500, 12-inch o.c. -225.0 C-VB-23. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW Smooth Torch -applied OB500, 12-inch o.c. -232.5 C-VB-24. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6 or GAFGLAS FlexPly 6 M Hot asphalt applied OB500, 12-inch o.c. -352.5 17 Fire barriers of FireOut'" Fire Barrier Coating, VersaShield Solo'" Fire -Resistant Slip Sheet are optional in all assemblies when overlying components are mechanically fastened. 18 The following products are interchangeable within the scope of this Evaluation Report: ACCEPTABLE ALTERNATES Listed Product Alternate EverGuard TPO EverGuard Extreme TPO EverGuard TPO Fleece -Back Membrane EverGuard Extreme TPO Fleece -Back Membrane EnergyGuard Polyiso Insulation EnergyGuard NH Polyiso Insulation EnergyGuard Ultra Polyiso Insulation EnergyGuard NH Ultra Polyiso Insulation EnergyGuard HD Polyiso Insulation EnergyGuard NH HD Polyiso Insulation EnergyGuard HD Plus Polyiso Insulation EnergyGuard NH HD Plus Polyiso Insulation 19 For System Types B-1, B-2, C-1, C-2, D-1 or Type D-2, GAF SA Vapor Retarder may be installed atop the roof deck prior to installation of the insulation and roof cover. Refer to FM Loss Prevention Data Sheet 1-29 (February 2020) for design and installation limitations. 20 "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'^ Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 5 of 156 NNEMO I etc. TABLE IA: ....REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer MDP System Deck No. (Note 1) Type Attach Type Attach Roof Cover (Note 15) IPA (Notes 6,7,8) (Notes 6,7,8) EverGuard Freedom TPO: W 1 Min. 19/32-inch plywood or Min. 1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional) Additional layers base GAF 2-Part EverGuard Freedom TPO / self adhered -52.5 OSB; 2 ft span EnergyGuard Ultra insulation, flat or tapered W 2 Min. 19/32-inch plywood or Min. 1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional) Additional layers base LRF-XF EverGuard Freedom TPO / self adhered -52.5 OSB; 2 ft span EnergyGuard Ultra insulation, flat or tapered EverGuard TPO: Min. 19/32-inch plywood or Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers base EverGuard TPO / #1121, TPO 6-Square, TPO W 3 OSB; 2ftspan EnergyGuard Ultra GAF 2-Part insulation, flat or tapered GAF 2-Part 3-Square, WB181 -52.5 W 4. Min. 19/32-inch plywood or Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional) Additional layers base GAF 2-Part EverGuard TPO / TPO QSA orTPO QSA LV50 -52.5 OSB; 2 ft span insulation, flat or tapered Min. 19/32-inch plywood or Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers base EverGuard TPO / #1121, TPO 6-Square, TPO W 5' OSB; 2 ft span EnergyGuard Ultra LRF-XF insulation, flat or tapered LRF-XF 3-Square, WB181 -52.5 W 6 Min. 19/32-inch plywood or Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional) Additional layers base LRF-XF EverGuard TPO / TPO QSA or TPO QSA LV50 -52.5 OSB; 2 ft span insulation, flat or tapered Min. 15/32-inch plywood; 2 Min. 1-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers base EverGuard TPO / #1121, TPO 6-Square, TPO W-7 ft EnergyGuard Ultra OB500 insulation, flatortapered OB500 3-Square, WB181 -67.5 W 8. Min. 15/32-inch plywood; 2 Min. 1-inch EnergyGuard Polyiso Insulation OB500 (Optional) Additional layers base OB500 EverGuard TPO / TPO QSA or TPO QSA LV50 -67.5 ft span insulation, flat or tapered Min. 15/32-inch plywood; 2 Min. 1-inch EnergyGuard Polyiso Insulation, OB500, 6- (Optional) Additional layers base OB500, 6- EverGuard TPO / #1121, TPO 6-Square, TPO W 9' ft span EnergyGuard Ultra inch o.c. insulation, flat or tapered inch o.c. 3-Square, WB181 75.0 W-10. Min. 15/32-inch plywood; 2 Min. 1-inch EnergyGuard Polyiso Insulation OB500, 6- (Optional) Additional layers base OB500, 6- EverGuard TPO / TPO QSA or TPO QSA LV50 -75.0 ft span inch o.c. insulation, flat or tapered inch o.c. EverGuard TPO Fleece -Back Membrane: Min. 19/32-inch plywood or Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers base EverGuard TPO Fleece -Back Membrane / W-11. OSB; 2 ft span EnergyGuard Ultra GAF 2-Part insulation, flat or tapered GAF 2-Part WB181, GAF 2-Part (spatter), LRF-XF -52.5 (spatter) or OB500 (spatter) Min. 19/32-inch plywood or Min. 1.S-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers base EverGuard TPO Fleece -Back Membrane / W 12. OSB; 2 ft span EnergyGuard Ultra LRF-XF insulation, flat or tapered LRF-XF WB181GAF Part (spatter), LRF-XF -52.5 ) or OBB500 (spatter) (spatter) Min. 15/32-inch plywood; 2 Min. 1-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers base EverGuard TPO Fleece -Back Membrane / W-13. ft span EnergyGuard Ultra OB500 insulation, flat or tapered OB500 WB1tter81, GAF -67.5 BPart(spatter),LRF-XF (spatter) or OB500 (spatter) Min. 15/32-inch plywood; 2 Min. 1-inch EnergyGuard Polyiso Insulation, OB500, 6- (Optional) Additional layers base OB500, 6- EverGuard TPO Fleece -Back Membrane / W-14. ft span EnergyGuard Ultra in o.c. insulation, flatortapered in o.c. WB181, GAF 2-Part (spatter), LRF-XF -75.0 (spatter) or OB500 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMo ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 6 of 156 NNEMO I etc. TABLE 113: .... .. . . SYSTEMTYPEA-2: MECHANICALLY Anchor Sheet ATTACHED ANCHOR SHEET, BONDED Base Insulation INSULATION, BONDED ROOF COVER Top Insulation Roof Cover (Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type YP (Notes Base Cap sf (p ) (Note 11) 6,7,8) 6,7,8) Min. GAFGLAS #75 Base Min. 1-inch Min. 0.5-inch EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base 32 ga., 1- 8-inch o.c. at EnergyGuard Polyiso Structodek High One or two plies Fleece -Back inch Sheet, GAFGLAS #80 5/8-inch dia. min. 4-inch laps Insulation, Density Fiberboard Ruberoid 20 Smooth, Membrane in hot plywood Ultima Base Sheet, tin caps with and 8-inch o.c. in EnergyGuard Ultra hot Roof Insulation or hot Ruberoid Mop asphalt or GAF 2- W-15. or 1-inch GAFGLAS Stratavent 12 ga. two, equally Polyiso Insulation or asphalt EnergyGuard Perlite asphalt Smooth, Ruberoid Part (spatter), -45.0 wood Nailable Venting Base annular ring spaced, EnergyGuard RH Recover Board or Min. Mop Smooth 1.5 or (spatter) plank; 2 ft Sheet, Ruberoid 20 shank nails staggered center Polyiso or min. 1.5- 0.75-inch EnergyGuard Ruberoid Mop Plus or OB5 or OB500 span Smooth rows inch EnergyGuard RA Perlite Roof Insulation Smooth in hot asphalt (spatter) or EnergyGuard RN (homogeneous) One or two plies Min. GAFGLAS #75 Base Min. 1-inch Ruberoid 20 Smooth, EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base 32 ga., 1- 8-inch o.c. at EnergyGuard Polyiso Ruberoid Mop Fleece -Back inch Sheet, GAFGLAS #80 5/8-inch dia. min. 4-inch laps Insulation Min. 0.25-inch Smooth Ruberoid, , Membrane in hot plywood Ultima Base Sheet, tin caps with and 8-inch o.c. in EnergyGuard Ultra hot DensDeck Prime or hot Mop Smooth 1.5 or asphalt or GAF 2- W-16. or 1-inch GAFGLAS Stratavent 12 ga. two, equally Polyiso Insulation or asphalt SECUROCK Gypsum- asphalt Ruberoid Mop Plus Part (spatter), -45.0 wood Nailable Venting Base annular ring spaced, EnergyGuard RH Fiber Roof Board Smooth in hot asphalt (spatter) plank; 2 ft Sheet, Ruberoid 20 shank nails staggered center Polyiso or min. 1.5- or Ruberoid HW 25 orOBSF-XFOO span Smooth rows inch EnergyGuard RA Smooth or Ruberoid (spatter) or EnergyGuard RN HW Smooth, torch- applied Min. Min. 1-inch Min. 0.5-inch EverGuard TPO 19/32- 32 ga., 1- 9-inch o.c. at EnergyGuard Polyiso Structodek High One or two plies Fleece -Back inch GAFGLAS #80 Ultima 5/8-inch dia. min. 4-inch laps Insulation, Density Fiberboard Ruberoid 20 Smooth, Membrane in hot plywood Base Sheet, GAFGLAS tin caps with and 9-inch o.c. in EnergyGuard Ultra hot Roof Insulation or hot Ruberoid Mop asphalt or GAF 2- W-17. or 1-inch Stratavent Nailable 12 ga. two, equally Polyiso Insulation or asphalt EnergyGuard Perlite asphalt Smooth, Ruberoid Part (spatter), -45.0 wood Venting Base Sheet, annular ring spaced, EnergyGuard RH Recover Board or Min. Mop Smooth 1.5 or LRF-XF (spatter) plank; 2 ft Ruberoid 20 Smooth shank nails staggered center Polyiso or min. 1.5- 0.75-inch EnergyGuard Ruberoid Mop Plus 500 OBpatteerr)) span rows inch EnergyGuard RA Perlite Roof Insulation Smooth in hot asphalt (spatter) (s or EnergyGuard RN (homogeneous) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 7 of 156 NNEMO I etc. TABLE 113: .... .. . . SYSTEMTYPEA-2: MECHANICALLY Anchor Sheet ATTACHED ANCHOR SHEET, BONDED Base Insulation INSULATION, BONDED ROOF COVER Top Insulation Roof Cover (Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes YP Type (Notes Base Cap sf (p ) (Note 11) 6,7,8) 6,7,8) One or two plies Min. Min. 1-inch Ruberoid 20 Smooth, EverGuard TPO 19/32- 32 ga., 1- 9-inch o.c. at EnergyGuard Polyiso Ruberoid Mop Fleece -Back inch GAFGLAS #80 Ultima 5/8-inch dia. min. 4-inch laps Insulation, Min. 0.25-inch Smooth, Ruberoid Membrane in hot plywood Base Sheet, GAFGLAS tin caps with and 9-inch o.c. in EnergyGuard Ultra hot DensDeck Prime or hot Mop Smooth 1.5 or asphalt or GAF 2- W-18. or 1-inch Stratavent Nailable 12 ga. two, equally Polyiso Insulation or asphalt SECUROCK Gypsum- asphalt Ruberoid Mop Plus Part (spatter), -45.0 wood Venting Base Sheet, annular ring spaced, EnergyGuard RH Fiber Roof Board Smooth in hot asphalt (spatter) plank; 2 ft Ruberoid 20 Smooth shank nails staggered center Polyiso or min. 1.5- or Ruberoid HW 25 or B5 or OBS00 span rows inch EnergyGuard RA Smooth or Ruberoid (spatter) or EnergyGuard RN HW Smooth, torch- applied Min. GAFGLAS#75 Base Min. 1-inch Min. 0.5-inch EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base 32 ga., 1- EnergyGuard Polyiso Structodek High One or two plies Fleece -Back 5/8-inch 6-inch o.c. at the Insulation, Density Fiberboard Ruberoid 20 Smooth, inch Sheet, GAFGLAS #80 diameter tin 4-inch lap and 6- EnergyGuard Ultra Roof Insulation or Ruberoid Mop Membrane in hot W-19. plywood Ultima Base Sheet, caps with 12 inch o.c. in two Polyiso Insulation or hot EnergyGuard Perlite hot Smooth, Ruberoid asphalt or GAF 2- -52.5 or 1-inch GAFGLAS Stratavent ga. annular staggered center EnergyGuard RH asphalt Recover Board or Min. asphalt Mop Smooth 1.5 or Part (spatter), wood Nailable Venting Base ring shank rows Polyiso or min. 1.5- 0.75-inch EnergyGuard Ruberoid Mop Plus LRF-XF (spatter) plank; 2 ft Sheet, Ruberoid 20 nails inch EnergyGuard RA Perlite Roof Insulation Smooth in hot asphalt or OB500 span Smooth or EnergyGuard RN (homogeneous) (spatter) One or two plies Min. GAFGLAS #75 Base Min. 1-inch Ruberoid 20 Smooth, EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base 32 ga., 1- EnergyGuard Polyiso Ruberoid Mop Fleece -Back inch Sheet, GAFGLAS #80 5/8-inch 6-inch o.c. at the Insulation, Min. 0.25-inch Smooth, Ruberoid Membrane in hot plywood Ultima Base Sheet, diameter tin 4-inch lap and 6- EnergyGuard Ultra hot DensDeck Prime or hot Mop Smooth 1.5 or asphalt or GAF 2- W-20. or 1-inch GAFGLAS Stratavent caps with 12 inch o.c. in two Polyiso Insulation or asphalt SECUROCK Gypsum- asphalt Ruberoid Mop Plus Part (spatter), -52.5 wood Nailable Venting Base ga. annular staggered center EnergyGuard RH Fiber Roof Board Smooth in hot asphalt (spatter) plank; 2 ft Sheet, Ruberoid 20 ring shank rows Polyiso or min. 1.5- or Ruberoid HW 25 orOBSF-XFOO span Smooth nails inch EnergyGuard RA Smooth or Ruberoid (spatter) or EnergyGuard RN HW Smooth, torch- applied NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 8 of 156 NNEMO I etc. TABLE 113: .... .. . . SYSTEMTYPEA-2: MECHANICALLY Anchor Sheet ATTACHED ANCHOR SHEET, BONDED Base Insulation INSULATION, BONDED ROOF COVER Top Insulation Roof Cover (Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type YP (Notes Base Cap sf (p ) (Note 11) 6,7,8) 6,7,8) Min. GAFGLAS #75 Base Min. 1-inch Min. 0.5-inch EverGuard TPO 19/32- Sheet, Tri-Ply #75 Base 32 ga., 1- EnergyGuard Polyiso Structodek High One or two plies Fleece -Back inch Sheet, GAFGLAS #80 5/8-inch 8-inch o.c. at the Insulation, Density Fiberboard Ruberoid 20 Smooth, Membrane in hot plywood Ultima Base Sheet, diameter tin 4-inch lap and 8- EnergyGuard Ultra hot Roof Insulation or hot Ruberoid Mop asphalt or GAF 2- W-21. inch GAFGLAS Stratavent caps with 12 inch o.c. in two Polyiso Insulation or asphalt EnergyGuard Perlite asphalt Smooth, Ruberoid Part (spatter), -52.5 w wood Nailable Venting Base ga. annular staggered center EnergyGuard RH Recover Board or Min. Mop Smooth 1.5 or LRF-XF (spatter) plank; 2 ft Sheet, Ruberoid 20 ring shank rows Polyiso or min. 1.5- 0.75-inch EnergyGuard Ruberoid Mop Plus 500 OBpatteerr)) span Smooth nails inch EnergyGuard RA Perlite Roof Insulation Smooth in hot asphalt (s (spatter)or EnergyGuard RN (homogeneous) One or two plies Min. GAFGLAS #75 Base Min. 1-inch Ruberoid 20 Smooth, EverGuard TPO 19/32- Sheet, Tri-Ply #75 Base 32 ga., 1- EnergyGuard Polyiso Ruberoid Mop Fleece -Back inch Sheet, GAFGLAS #80 5/8-inch 8-inch o.c. at the Insulation, Min. 0.25-inch Smooth, Ruberoid Membrane in hot plywood Ultima Base Sheet, diameter tin 4-inch lap and 8- EnergyGuard Ultra hot DensDeck Prime or hot Mop Smooth 1.5 or asphalt or GAF 2- W-22. or 1-inch GAFGLAS Stratavent caps with 12 inch o.c. in two Polyiso Insulation or asphalt SECUROCK Gypsum- asphalt Ruberoid Mop Plus Part (spatter), -52.5 wood Nailable Venting Base ga. annular staggered center EnergyGuard RH Fiber Roof Board Smooth in hot asphalt LRF-XF (spatter) plank; 2 ft Sheet, Ruberoid 20 ring shank rows Polyiso or min. 1.5- or Ruberoid HW 25 or OB500 span Smooth nails inch EnergyGuard RA Smooth or Ruberoid (spatter) or EnergyGuard RN HW Smooth, torch- applied Min. Min. 1-inch Min. 0.5-inch EverGuard TPO 19/32- 32 ga., 1- EnergyGuard Polyiso Structodek High One or two plies Fleece -Back inch GAFGLAS #80 Ultima 5/8-inch dia. 8-inch o.c. at the Insulation, Density Fiberboard Ruberoid 20 Smooth, Membrane in hot plywood Base Sheet, GAFGLAS tin caps with 4-inch lap and 8- EnergyGuard Ultra hot Roof Insulation or hot Ruberoid Mop asp2- W-23. orGAF or 1-inch Stratavent Nailable 12 ga. inch o.c. in three Polyiso Insulation or asphalt EnergyGuard Perlite asphalt Smooth, Ruberoid Part (spatter), -75.0* wood Venting Base Sheet, annular ring staggered center EnergyGuard RH Recover Board or Min. Mop Smooth 1.5 or (spatter) plank; 2 ft Ruberoid 20 Smooth shank nails rows Polyiso or min. 1.5- 0.75-inch EnergyGuard Ruberoid Mop Plus orOB5F-XF00 span inch EnergyGuard RA Perlite Roof Insulation Smooth in hot asphalt (spatter) or EnergyGuard RN (homogeneous) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 9 of 156 NNEMO I etc. TABLE 113: .... .. . . SYSTEMTYPEA-2: MECHANICALLY Anchor Sheet ATTACHED ANCHOR SHEET, BONDED Base Insulation INSULATION, BONDED ROOF COVER Top Insulation Roof Cover (Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type YP (Notes Base Cap sf (p ) (Note 11) 6,7,8) 6,7,8) One or two plies Min. Min. 1-inch Ruberoid 20 Smooth, EverGuard TPO 19/32- 32 ga., 1- EnergyGuard Polyiso Ruberoid Mop Fleece -Back inch GAFGLAS #80 Ultima 5/8-inch dia. 8-inch o.c. at the Insulation, Min. inch SmoothRuberoid , Membrane hot plywood Base Sheet, GAFGLAS tin caps with 4-inch lap and 8- EnergyGuard Ultra hot DensPrime or Deck hot Mop Smooth 1.5 or asphalt or GAF 2- W-24. or 1-inch Stratavent Nailable 12 ga. inch o.c. in three Polyiso Insulation or asphalt SECUROCK Gypsum- asphalt Ruberoid Mop Plus Part (spatter), -75.0 wood Venting Base Sheet, annular ring staggered center EnergyGuard RH Fiber Roof Board Smooth o hot asphalt (spatter) plank; 2 ft Ruberoid 20 Smooth shank nails rows Polyiso or min. 1.5- or Ruberoid HW 25 or OBSURF-XF OO OBer) span inch EnergyGuard RA Smooth or Ruberoid (spatter) (s or EnergyGuard RN HW Smooth, torch- applied GAFGLAS Stratavent Min. GAFGLAS #75 Base Perforated Venting EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base 32 ga., 1- 8-inch o.c. at Min. 1-inch Base, loose laid, Fleece -Back inch Sheet, GAFGLAS #80 5/8-inch dia. min. 4-inch laps EnergyGuard Polyiso followed by one or Membrane in hot plywood Ultima Base Sheet, tin caps with and 8-inch o.c. in Insulation, hot (Optional) Additional hot two plies Ruberoid 20 asphalt or GAF 2- W-25. or 1-inch GAFGLAS Stratavent 12 ga. two, equally EnergyGuard Ultra asphalt layer(s) base asphalt Smooth, Ruberoid Part (spatter), -45.0 wood Nailable Venting Base annular ring spaced, Polyiso Insulation or insulation Mop Smooth, LRF-XF (spatter) plank; 2 ft Sheet, Ruberoid 20 shank nails staggered center EnergyGuard RH Ruberoid Mop Smooth OB SOO span Smooth rows Polyiso 1.5 or Ruberoid Mop (s (spatter) Plus Smooth in hot asphalt GAFGLAS Stratavent Min. GAFGLAS #80 Ultima Perforated Venting EverGuard TPO 19/32- Base Sheet, GAFGLAS 32 ga., 1- 9-inch o.c. at the Min. 1-inch Base, loose laid, Fleece -Back inch Stratavent Eliminator 5/8-inch dia. min. 4-inch lap EnergyGuard Polyiso followed by one or Membrane in hot plywood Nailable Venting Base tin caps with and 9-inch o.c. in Insulation, hot (Optional) Additional hot two plies Ruberoid 20 asphalt or GAF 2- W-26. or 1-inch Sheet, Ruberoid 20 12 ga. two, equally EnergyGuard Ultra asphalt layer(s) base asphalt SmoothRuberoid , Part (spatter), -45.0 wood Smooth, Ruberoid Mop annular ring spaced, Polyiso Insulation or insulation Mop Smooth, LRF-XF (spatter) plank; 2 ft Smooth, Ruberoid Mop shank nails staggered center EnergyGuard RH Ruberoid Mop Smooth SOO OBpatteerr)) span Smooth 1.5 rows Polyiso 1.5 or Ruberoid Mop (s (spatter) Plus Smooth in hot asphalt NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 10 of 156 NNEMO I etc. TABLE 113: .... .. . . SYSTEIVITYPEA-2: MECHANICALLY Anchor Sheet ATTACHED ANCHOR SHEET, BONDED Base Insulation INSULATION, BONDED ROOF COVER Top Insulation Roof Cover (Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type YP (Notes Base Cap sf (p ) (Note 11) 6,7,8) 6,7,8) GAFGLAS Stratavent Min. GAFGLAS #75 Base Perforated Venting EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base 32 ga., 1- 6-inch o.c. at Min. 1-inch Base, loose laid, Fleece -Back inch Sheet, GAFGLAS #80 5/8-inch dia. min. 4-inch laps EnergyGuard Polyiso followed by one or Membrane in hot plywood Ultima Base Sheet, tin caps with and 6-inch o.c. in Insulation, hot (Optional) Additional hot two plies Ruberoid 20 asphalt or GAF 2- W-27. or 1-inch GAFGLAS Stratavent 11 ga. two, equally EnergyGuard Ultra asphalt layer(s) base asphalt SmoothRuberoid , Part (spatter), -52.5 wood Nailable Venting Base annular ring spaced, Polyiso Insulation or insulation Mop Smooth, LRF-XF (spatter) plank; 2 ft Sheet, Ruberoid 20 shank nails staggered center EnergyGuard RH Ruberoid Mop Smooth OB SOO span Smooth rows Polyiso 1.5 or Ruberoid Mop (s (spatter) Plus Smooth in hot asphalt GAFGLAS Stratavent Min. GAFGLAS #75 Base Perforated Venting EverGuard TPO 19/32- Sheet, Tri-Ply #75 Base 32 ga., 1- Min. 1-inch Base, loose laid, Fleece -Back inch Sheet, GAFGLAS #80 5/8-inch 8-inch o.c. at the EnergyGuard Polyiso followed by one or Membrane in hot plywood Ultima Base Sheet, diameter tin 4-inch lap and 8- Insulation, hot (Optional) Additional hot two plies Ruberoid 20 asphalt or GAF 2- W-28. or 1-inch GAFGLAS Stratavent caps with 12 inch o.c. in two EnergyGuard Ultra asphalt layer(s) base asphalt Smooth, Ruberoid Part (spatter), -52.5 wood Nailable Venting Base ga. annular staggered center Polyiso Insulation or insulation Mop Smooth, LRF-XF (spatter) plank; 2 ft Sheet, Ruberoid 20 ring shank rows EnergyGuard RH Ruberoid Mop Smooth or OBS00 span Smooth nails Polyiso 1.5 or Ruberoid Mop (spatter) Plus Smooth in hot asphalt GAFGLAS Stratavent Min. Perforated Venting EverGuard TPO 19/32- 32 ga., 1- Min. 1-inch Base, loose laid, Fleece -Back inch GAFGLAS #80 Ultima 5/8-inch dia. 8-inch o.c. at the EnergyGuard Polyiso followed by one or Membrane in hot plywood Base Sheet, GAFGLAS tin caps with 4-inch lap and 8- Insulation, hot (Optional) Additional hot two plies Ruberoid 20 asphalt or GAF 2- W-29. or 1-inch Stratavent Nailable 12 ga. inch o.c. in three EnergyGuard Ultra asphalt layer(s) base asphalt Smooth, Ruberoid Part (spatter), -75.0* wood Venting Base Sheet, annular ring staggered center Polyiso Insulation or insulation Mop Smooth, LRF-XF (spatter) plank; 2 ft Ruberoid 20 Smooth shank nails rows EnergyGuard RH Ruberoid Mop Smooth or OBS00 span Polyiso 1.5 or Ruberoid Mop (spatter) Plus Smooth in hot asphalt NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 11 of 156 NNEMO I etc. TABLE 1c: ..REROOF (TEAR -OFF) OR RECOVER SYSTEIVITYPEA-2: MECHANICALLY Anchor Sheet ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF Base Insulation Top Insulation COVER Roof Cover (Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type YP (Notes Base Cap sf (p ) (Note 11) 6,7,8) 6,7,8) Min. GAFGLAS #75 Base Min. 1-inch Min. 0.5-inch EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base 16-inch o.c. at the EnergyGuard Polyiso Structodek High Density One or two plies Fleece -Back inch Sheet, GAFGLAS #80 min. 4-inch lap Insulation, Fiberboard Roof Ruberoid 20 Smooth, Membrane in plywood Ultima Base Sheet, Note 2 (#14 and 16-inch o.c. in EnergyGuard Ultra hot Insulation or hot Ruberoid Mop Smooth, hot asphalt or W-30. or 1-inch GAFGLAS Stratavent ONLY) two, equally Polyiso Insulation or asphalt EnergyGuard Perlite asphalt Ruberoid Mop Smooth GAF 2-Part -52.5 wood Nailable Venting Base spaced, staggered EnergyGuard RH Recover Board or Min. 1.5 or Ruberoid Mop Plus (spatter), LRF- plank; 2 ft Sheet, Ruberoid 20 center rows Polyiso or min. 1.5- 0.75-inch EnergyGuard Smooth in hot asphalt XF (spatter) or span Smooth inch EnergyGuard RA Perlite Roof Insulation OB500 (spatter) or EnergyGuard RN I (homogeneous) Min. GAFGLAS #75 Base Min. 1-inch One or two plies EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base 16-inch o.c. at the EnergyGuard Polyiso Ruberoid 20 Smooth, Fleece -Back inch Sheet, GAFGLAS #80 min. 4-inch lap Insulation, Min. 0.25-inch Ruberoid Mop Smooth, Membrane in plywood Ultima Base Sheet, Note 2 (#14 and 16-inch o.c. in EnergyGuard Ultra hot DensDeck Prime or hot Ruberoid Mop Smooth hot asphalt or W-31. or 1-inch GAFGLAS Stratavent ONLY) two, equally Polyiso Insulation or asphalt SECUROCK Gypsum- asphalt 1.5 or Ruberoid Mop Plus GAF 2-Part -52.5 wood Nailable Venting Base spaced, staggered EnergyGuard RH Fiber Roof Board Smooth in hot asphalt or (spatter), LRF- plank; 2 ft Sheet, Ruberoid 20 center rows Polyiso or min. 1.5- Ruberoid HW 25 Smooth XF (spatter) or span Smooth inch EnergyGuard RA or Ruberoid HW Smooth, OB500 (spatter) or EnergyGuard RN torch -applied Min. GAFGLAS #75 Base Min. 1-inch Min. 0.5-inch EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base 12-inch o.c. at the EnergyGuard Polyiso Structodek High Density One or two plies Fleece -Back inch Sheet, GAFGLAS #80 min. 4-inch lap Insulation, Fiberboard Roof Ruberoid 20 Smooth, Membrane in plywood Ultima Base Sheet, Note 2 (#14 and 12-inch o.c. in EnergyGuard Ultra hot Insulation or hot Ruberoid Mop Smooth, hot asphalt or W-32. or 1-inch GAFGLAS Stratavent ONLY) two, equally Polyiso Insulation or asphalt EnergyGuard Perlite asphalt Ruberoid Mop Smooth GAF 2-Part -60.0 wood Nailable Venting Base spaced, staggered EnergyGuard RH Recover Board or Min. 1.5 or Ruberoid Mop Plus (spatter), LRF- plank; 2 ft Sheet, Ruberoid 20 center rows Polyiso or min. 1.5- 0.75-inch EnergyGuard Smooth in hot asphalt XF (spatter) or span Smooth inch EnergyGuard RA Perlite Roof Insulation OB500 (spatter) or EnergyGuard RN (homogeneous) Min. GAFGLAS #75 Base Min. 1-inch One or two plies EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base 12-inch o.c. at the EnergyGuard Polyiso Ruberoid 20 Smooth, Fleece -Back inch Sheet, GAFGLAS #80 min. 4-inch lap Insulation, Min. 0.25-inch Ruberoid Mop Smooth, Membrane in plywood Ultima Base Sheet, Note 2 (#14 and 12-inch o.c. in EnergyGuard Ultra hot DensDeck Prime or hot Ruberoid Mop Smooth hot asphalt or W-33. or 1-inch GAFGLAS Stratavent ONLY) two, equally Polyiso Insulation or asphalt SECUROCK Gypsum- asphalt 1.5 or Ruberoid Mop Plus GAF 2-Part -60.0 wood Nailable Venting Base spaced, staggered EnergyGuard RH Fiber Roof Board Smooth in hot asphalt or (spatter), LRF- plank; 2 ft Sheet, Ruberoid 20 center rows Polyiso min. 1.5- Ruberoid 25 Smooth XF (spatter) or span Smooth r inch EnergyGuard RA Ruberoid d HW Smooth, OB500 (spatter) or EnergyGuard RN torch -applied to NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 12 of 156 NNEMO I etc. TABLE 1c: ..REROOF (TEAR -OFF) OR RECOVER SYSTEIVITYPEA-2: MECHANICALLY Anchor Sheet ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF Base Insulation Top Insulation COVER Roof Cover (Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type YP (Notes Base Cap sf (p ) (Note 11) 6,7,8) 6,7,8) Min. GAFGLAS #75 Base Min. 1-inch Min. 0.5-inch EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base EnergyGuard Polyiso Structodek High Density One or two plies Fleece -Back inch Sheet, GAFGLAS #80 8-inch o.c. at the Insulation, Fiberboard Roof Ruberoid 20 Smooth, Membrane in plywood Ultima Base Sheet, Note 2 (#14 4-inch lap and 8- EnergyGuard Ultra hot Insulation or hot Ruberoid Mop Smooth, hot asphalt or W-34. or 1-inch GAFGLAS Stratavent ONLY) inch o.c. in three Polyiso Insulation or asphalt EnergyGuard Perlite asphalt Ruberoid Mop Smooth GAF 2-Part -75.0* wood Nailable Venting Base staggered center EnergyGuard RH Recover Board or Min. 1.5 or Ruberoid Mop Plus (spatter), plank; 2 ft Sheet, Ruberoid 20 rows Polyiso or min. 1.5- 0.75-inch EnergyGuard Smooth in hot asphalt XF (spatterr)) o span Smooth inch EnergyGuard RA Perlite Roof Insulation OB500 (spatter) or EnergyGuard RN I (homogeneous) Min. GAFGLAS #75 Base Min. 1-inch One or two plies EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base EnergyGuard Polyiso Ruberoid 20 Smooth, Fleece -Back inch Sheet, GAFGLAS #80 8-inch o.c. at the Insulation, Min. 0.25-inch Ruberoid Mop Smooth, Membrane in plywood Ultima Base Sheet, Note 2 (#14 4-inch lap and 8- EnergyGuard Ultra hot DensDeck Prime or hot Ruberoid Mop Smooth hot asphalt or W-35. or 1-inch GAFGLAS Stratavent ONLY) inch o.c. in three Polyiso Insulation or asphalt SECUROCK Gypsum- asphalt 1.5 or Ruberoid Mop Plus GAF 2-Part 82.5 wood Nailable Venting Base staggered center EnergyGuard RH Fiber Roof Board Smooth in hot asphalt or (spatter), LRF- plank; 2 ft Sheet, Ruberoid 20 rows Polyiso or min. 1.5- Ruberoid HW 25 Smooth XF (spatter) or span Smooth inch EnergyGuard RA or Ruberoid HW Smooth, OB500 (spatter) or EnergyGuard RN torch -applied Min. GAFGLAS #75 Base GAFGLAS Stratavent EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base 16-inch o.c. at the Min. 1-inch Perforated Venting Base, Fleece -Back inch Sheet, GAFGLAS #80 min. 4-inch lap EnergyGuard Polyiso loose laid, followed by Membrane in plywood Ultima Base Sheet, Note 2 (#14 and 16-inch o.c. in Insulation, hot (Optional) Additional hot one or two plies hot asphalt or W-36. or 1-inch GAFGLAS Stratavent ONLY) two, equally EnergyGuard Ultra asphalt layer(s) base insulation asphalt d h, Ruberoi20 Smoot GAF 2-Part -52.5 wood Nailable Venting Base spaced, staggered Polyiso Insulation or Ruberoid Mop Smooth, (spatter), LRF- plank; 2 ft Sheet, Ruberoid 20 center rows EnergyGuard RH Ruberoid Mop Smooth XF (spatter) or span Smooth Polyiso 1.5 or Ruberoid Mop Plus OB500 (spatter) Smooth in hot asphalt Min. GAFGLAS #75 Base GAFGLAS Stratavent EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base 12-inch o.c. at the Min. 1-inch Perforated Venting Base, Fleece -Back inch Sheet, GAFGLAS #80 min. 4-inch lap EnergyGuard Polyiso loose laid, followed by Membrane in plywood Ultima Base Sheet, Note 2 (#14 and 12-inch o.c. in Insulation, hot (Optional) Additional hot one or two plies hot asphalt or W-37. or 1-inch GAFGLAS Stratavent ONLY) two, equally EnergyGuard Ultra asphalt layer(s) base insulation asphalt Ruberoid 20 Smooth, GAF Part -60.0 wood Nailable Venting Base spaced, staggered Polyiso Insulation or Ruberoid Mop Smooth, (spatter), LRF- plank; 2 ft Sheet, Ruberoid 20 center rows EnergyGuard RH Ruberoid Mop Smooth XF (spatter) or span Smooth Polyiso 1.5 or Ruberoid Mop Plus OB500 (spatter) Smooth in hot asphalt NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 13 of 156 NNEMO I etc. TABLE 1c: ..REROOF SYSTEIVITYPEA-2: MECHANICALLY Anchor Sheet (TEAR -OFF) OR RECOVER ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF Base Insulation Top Insulation COVER Roof Cover (Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type (Notes Type YP (Notes Base Cap sf (p ) (Note 11) 6,7,8) 6,7,8) Min. GAFGLAS #75 Base GAFGLAS Stratavent EverGuard TPO 15/32- Sheet, Tri-Ply #75 Base Min. 1-inch Perforated Venting Base, Fleece -Back inch Sheet, GAFGLAS #80 8-inch o.c. at the EnergyGuard Polyiso loose laid, followed by Membrane in plywood Ultima Base Sheet, Note 2 (#14 4-inch lap and 8- Insulation, hot (Optional) Additional hot one or two plies hot asphalt or W-38. inch GAFGLAS ONLY) inch o.c. in three EnergyGuard Ultra asphalt layer(s) base insulation asphalt Ruberoid 20 Smooth, GAF -82.5* wood w o emit gas Venting Base staggered center Polyiso Insulation or Ruberoid Mop Smooth, tePart (spatter), LRF- plank; 2 ft Sheet, Sheet, Ruberoid 20 rows EnergyGuard RH Ruberoid Mop Smooth XF (spatter) span Smooth Polyiso 1.5 or Ruberoid Mop Plus OB500 (spatttor eo r) Smooth in hot asphalt ID: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER ATTACHEDTABLE SYSTEIVITYPEB-1: MECHANICALLY BASE INSULATION,BONDED TOP INSULATION,BONDED ROO System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) Type Fasten (Note 11) Attach Type Attach Roof Cover (Note 15) (Psf) (Notes 6,7,8) EverGuard FreedomTPO Applications: W-39. Min. 15/32-inch plywood or Min 2-inch EnergyGuard Polyiso Note 2 (#14 1 per Min. 0.25-inch SECUROCK GAF 2-Part, LRF-M, EverGuard Freedom TPO/ self adhered -52.5 1-inch wood plank; 2 ft span Insulation, EnergyGuard RH Fastener only) 2.0 ft' Gypsum -Fiber Roof Board LRF-XF or OB500 EverGuard TPO Applications: Min. 15/32-inch plywood or Min 2-inch EnergyGuard Polyiso Note 2 (#14 1 per Min. 0.25-inch SECUROCK GAF 2-Part, LRF-M, EverGuard TPO / #1121, TPO 6-Square, TPO W-40. 1-inch wood plank; 2 ft span Insulation, EnergyGuard RH Fastener only) 2.0 ft' Gypsum -Fiber Roof Board LRF-XF or OB500 3-Square, TPO QSA or TPO QSA LV50 -52.5 W 41 Min. 19/32-inch plywood or Min. 3-inch EnergyGuard Ultra Note 2 1 per Min. 0.25-inch SECUROCK LRF-XF4-inch o.c. , EverGuard TPO / TPO QSA or TPO QSA 82 5 1-inch wood plank; 2 ft span 1.0 ft Gypsum -Fiber Roof Board LV50 W 42 Min. 19/32-inch plywood or Min. 3-inch EnergyGuard Polyiso Note 2 1 per Min. 0.25-inch SECUROCK OB500, 4-inch o.c. EverGuard TPO / TPO QSA or TPO QSA 82 5 1-inch wood plank; 2 ft span Insulation or EnergyGuard Ultra 1.0 ft2 Gypsum -Fiber Roof Board LV50 W 43 Min. 19/32-inch plywood or Min. 3-inch EnergyGuard Ultra Note 2 1 per Min. 0.25-inch SECUROCK LRF-XF, 4-inch o.c. EverGuard TPO / #1121 -120.0 1-inch wood plank; 2 ft span 1.0 ft2 Gypsum -Fiber Roof Board W 44 Min. 19/32-inch plywood or Min. 3-inch EnergyGuard Polyiso Note 2 1 per Min. 0.25-inch SECUROCK OB500, 4-inch o.c. EverGuard TPO / #1121 -120.0 1-inch wood plank; 2 ft span Insulation or EnergyGuard Ultra 1.0 ft' 1 Gypsum -Fiber Roof Board EverGuard TPO Fleece -Back Membrane Applications: Min. 15/32-inch plywood or Min 2-inch EnergyGuard Polyiso Note 2 (#14 1 per Min. 0.25-inch SECUROCK GAF 2-Part, LRF-M, EverGuard TPO Fleece -Back Membrane / W 45. 1-inch wood plank; 2 ft span Insulation, EnergyGuard RH Fastener only) 2.0 ft2 Gypsum -Fiber Roof Board LRF-XF or OB500 GAF 2-Part (spatter), LRF-XF (spatter) or -52.5 OB500 (spatter) W 46 Min. 19/32-inch plywood or Min. 3-inch EnergyGuard Ultra Note 2 1 per Min. 0.25-inch SECUROCK LRF-XF, 4-inch o.c. EverGuard TPO Fleece -Back Membrane / -120.0 1-inch wood plank; 2 ft span 1.0 ft Gypsum-Fiber Roof Board OB500 (spatter) W 47 Min. 19/32-inch plywood or Min. 3-inch EnergyGuard Polyiso Note 2 1 per Min. 0.25-inch SECUROCK OB500, 4-inch o.c. EverGuard TPO Fleece -Back Membrane / -120.0 1-inch wood plank; 2 ft span Insulation or EnergyGuard Ultra 1.0 ft' Gypsum -Fiber Roof Board OB500 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 14 of 156 NNEMOjetc. TABLE IE: ....REROOF (TEAR -OFF) OR RECOVER BONDEDSYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, ROOF System Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP Deck (Note 1) No. Layer (Note 13) Type Fasteners (Note 11) Attach Base Cap (psf) EverGuard TPO: Min. 15/32-inch plywood (Optional) One Min. 1.5-inch 1 per EverGuard TPO / #1121, TPO 3- W-48. or 1-inch wood plank; 2 or more layers, EnergyGuard Polyiso Note 2 (#14 Fastener only) 2.7 ft2 None Square, TPO QSA or TPO QSA LV50 -37.5* ft span any combination Insulation Min. 15/32-inch plywood (Optional) One Min. 2-inch 1 per erft' TPO 3 , 121- EverGuard TPO / #1 1 21 W-49. or 1-inch wood plank; 2 or more layers, EnergyGuard Polyiso Note 2 (#14 Fastener only) 2 7 None Square, TPO QSA QSA LV50 -45.0* ft span any combination Insulation Min. 15/32-inch plywood (Optional) One Min. 0.25-inch W-50. or 1-inch wood plank; 2 or more layers, DensDeck Prime or Note 2 (#14 Fastener only) 1 per None EverGuard TPO / #1121, TPO 3- -45.0* ft span any combination SECUROCK Gypsum- 2.7 ft2 Square, TPO QSA or TPO QSA LV50 Fiber Roof Board Min. 15/32-inch plywood (Optional) One Min. 1.5-inch 1 per EverGuard TPO / #1121, TPO 3- W-51. or 1-inch wood plank; 2 or more layers, EnergyGuard Polyiso Note 2 (#14 Fastener only) 2.0 ft2 None Square, TPO QSA or TPO QSA LV50 -45.0* ft span any combination Insulation APA rated, 19/32 CAT, (Optional) One Min. 1-inch EverGuard TPO / #1121, WB181, W-52. 0.578 in., Exposure 1 or more layers, EnergyGuard Polyiso Note 2 (#14 Fastener only) 2 per None TPO 3-Square, TPO QSA or TPO -45.0* OSB; 2 ft span any combination Insulation QSA LV50 Min. 15/32-inch plywood (Optional) One Min. 1.5-inch 1 per EverGuard TPO / #1121, TPO 3- W-53. or 1-inch wood plank; 2 or more layers, EnergyGuard Polyiso Note 2 1 8 ft' None Square, TPO QSA or TPO QSA LV50 -52.5 ft span any combination Insulation Min. 15/32-inch plywood (Optional) One Min. 0.25-inch 1 per EverGuard TPO / #1121, TPO 3- W-54. or 1-inch wood plank; 2 or more layers, DensDeck Prime Note 2 1.8 ft' None Square, TPO QSA or TPO QSA LV50 -52.5 ft span any combination Min. 15/32-inch plywood (Optional) One Min. 0.25-inch 1 per EverGuard TPO / #1121, TPO 3- W-55. or 1-inch wood plank; 2 or more layers, SECUROCK Gypsum- Note 2 1.8 ft2 None Square, TPO QSA or TPO QSA LV50 -60.0 ft span any combination Fiber Roof Board Min. 15/32-inch plywood (Optional) One Min. 1.5-inch 1 per EverGuard TPO / #1121, TPO 3- W-56. or 1-inch wood plank; 2 or more layers, EnergyGuard Polyiso Note 2 1.6 ft2 None Square, TPO QSA or TPO QSA LV50 -60.0 ft span any combination Insulation Min. 15/32-inch plywood (Optional) One Min. 1.5-inch 1 per 1 21 TPO 3 , 121- EverGuard TPO / #1 W-57. or 1-inch wood plank; 2 or more layers, EnergyGuard Polyiso Note 2 (#14 Fastener only) 1.3 ft2 None Square, TPO QSA QSA LV50 -60.0 ft span any combination Insulation EverGuard TPO Fleece -Back Membrane: Min. 15/32-inch plywood (Optional) One Min. 1.5-inch EverGuard TPO Fleece -Back W-58. or 1-inch wood plank; 2 or more layers, EnergyGuard Polyiso Note 2 (#14 Fastener only) 1 per 2.7 ft2 None Membrane / GAF 2-Part (spatter), -37.5* ft span any combination Insulation LRF-XF (spatter) or OB500 (spatter) Min. 15/32-inch plywood (Optional) One Min. 2-inch EverGuard TPO Fleece -Back W-59. or 1-inch wood plank; 2 or more layers, EnergyGuard Polyiso Note 2 (#14 Fastener only) 2 ft' None Membrane / GAF 2-Part (spatter), -45.0* ft span any combination Insulation .per7 LRF-XF (spatter) or OB500 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 71^ Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 15 of 156 NNEMO I etc. TABLE IE: ....REROOF (TEAR -OFF) OR RECOVER System Base Insulation BONDEDSYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, Top Insulation Layer ROOF Roof Cover (Note 15) MOP No. Deck (Note 1) Layer (Note 13) (psf) Type Fasteners (Note 11) Attach Base Cap Min. 15/32-inch plywood (Optional) One Min. 0.25-inch EverGuard TPO Fleece -Back W-60. or 1-inch wood plank; 2 or more layers, DensDeck Prime or Note 2 (#14 Fastener only) 1 per None Membrane / GAF 2-Part (spatter), -45.0* ft span any combination SECUROCK Gypsum- 2.7 ft2 LRF-XF (spatter) or OB500 (spatter) Fiber Roof Board Min. 15/32-inch plywood (Optional) One Min. 1.5-inch EverGuard TPO Fleece -Back W-61. or 1-inch wood plank; 2 or more layers, EnergyGuard Polyiso Note 2 (#14 Fastener only) 1 per None Membrane / GAF 2-Part (Spatter), -45.0* ft span any combination Insulation 2.0 ft2 LRF-XF (spatter) or OB500 (spatter) APA rated, 19/32 CAT, (Optional) One Min. 1-inch EverGuard TPO Fleece -Back W-62. 0.578 in., Exposure 1 or more layers, EnergyGuard Polyiso Note 2 (#14 Fastener only) 1 per None Membrane /GAF 2-Part (spatter), -45.0* OSB; 2 ft span any combination Insulation 2.0 ft2 LRF-XF (spatter) or OB500 (spatter) Min. 15/32-inch plywood (Optional) One Min. 1.5-inch EverGuard TPO Fleece -Back W-63. or 1-inch wood plank; 2 or more layers, EnergyGuard Polyiso Note 2 1 er None Membrane / GAF 2-Part (spatter), -52.5 ft span any combination Insulation 1 8 ft, LRF-XF (spatter) or OB500 (spatter) Min. 15/32-inch plywood (Optional) One EverGuard TPO Fleece -Back W-64. or 1-inch wood plank; 2 or more layers, Min. 0.25-inch Note 2 1 per None Membrane / GAF 2-Part (spatter), -52.5 ft span any combination DensDeck Prime 1.8 ft' LRF-XF (spatter) or OB500 (spatter) Min. 15/32-inch plywood (Optional) One Min. 0.25-inch EverGuard TPO Fleece -Back W-65. or 1-inch wood plank; 2 or more layers, SECUROCK Gypsum- Note 2 1 per 1.8 ft' None Membrane / GAF 2-Part (spatter), -60.0 ft span any combination Fiber Roof Board LRF-XF (spatter) or OB500 (spatter) Min. 15/32-inch plywood (Optional) One Min. 1.5-inch EverGuard TPO Fleece -Back W-66. or 1-inch wood plank; 2 or more layers, EnergyGuard Polyiso Note 2 1 per 1.6 ft2 None Membrane / GAF 2-Part (spatter), -60.0 ft span any combination Insulation LRF-XF (spatter) or OB500 (spatter) Drill-Tec #14 with Drill-Tec 3 in. One or two plies Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop EverGuard TPO Fleece -Back Min. 19 32-inch wood / plywood (Optional) One Min. 0.25-inch Ribbed Galvalume Plate (Flat) or 1 per Smooth 1.5 or Ruberoid Mop Plus Membrane in hot asphalt or GAF 2- W-67. or 1-inch wood plank; 2 or more layers, SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plate or Drill- 1 8 ft� Smooth in hot asphalt or One or two Part (spatter), LRF-XF (spatter) or -60.0 ft span any combination Fiber Roof Board Tec #14 HD Fastener with Drill-Tec plies Ruberoid HW 25 Smooth or OB500 (spatter) 3" Flat Steel Plate Ruberoid HW Smooth, torch -applied Min. 15/32-inch plywood (Optional) One Min. 1.5-inch EverGuard TPO Fleece -Back W-68. or 1-inch wood plank; 2 or more layers, EnergyGuard Polyiso Note 2 (#14 Fastener only) 1 per None Membrane / GAF 2-Part (spatter), -60.0 ft span any combination Insulation 1.3 ft2 LRF-XF (spatter) or OB500 (spatter) Min. 19/32-inch plywood (Optional) One Min. 0.25-inch W-69. or 1-inch wood plank; 2 or more layers, SECUROCK Gypsum- ec #12 with Drill-Tec rAccuTrac 1 per None EverGuard TPO Fleece -Back 82.5 ft span any combination Fiber Roof Board Flat Plate 1.3 ft' Membrane in hot asphalt NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'^ Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 16 of 156 NNEMO I etc. TABLE 1F: ....REROOF (TEAR -OFF) OR RECOVER System Deck Insulation PLATE-BONDEDSYSTEM TYPE C-2: ROOF Attachment Roof Cover (Note 156) MDP Fasteners (Note 11) Spacing No. (Note 1) (Note 13) (Psf) One or more layers, any Drill-Tec XHD Fastener and Drill-Tec 1 per 2.7 ftz (12 parts per 4 x 8 ft board) EverGuard TPO bonded to Drill-Tec RhinoBond Min. 19/32-inch OSB; 2 ft combination, RhinoBond TPO XHD Plates or Drill- Fasteners are 8-, 24- and 40-inches from TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W-70. span preliminarily attached Tec RhinoBond TPO XHD Tread Safe the board's long edge and 12-, 36-, 60- and Tread Safe Plates with RhinoBond Portable -30.0 (Tread Safe =min. 2-inch Plates 84-inches from the board's short edge. Bonding Tool, per manufacturer's published thick insulation) instructions. Min. 15/32-inch plywood, min. 19/32-inch One or more layers, any Drill-Tec #14 (min. 1-inch EverGuard TPO bonded to Drill-Tec RhinoBond OSB or 1-inch wood combination, embedment into joist) and Drill-Tec 12-inch o.c. along wood supports, 96-inch TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W 71. plank atoopp nominal 2 x 8 Preliminarily attached RhinoBond TPO XHD Plates or Drill- O.C. Tread Safe Plates with RhinoBond Portable -30.0 inch lumber supports (Tread Safe = min. 2-inch Tec RhinoBond TPO XHD Tread SafeBonding Tool, per manufacturer's published spaced max. 96-inco.c. thick insulation) Plates through to wood supports instructions. Min. 15inch plywoodd,, min. 19/32-inch One or more layers, any Drill-Tec #14 (min. 1-inch EverGuard TPO bonded to Drill-Tec RhinoBond Oor 1-inch wood combination (Tread Safe embedment into joist) and Drill-Tec . along wood supports, 48-inch 24-inch o.c. TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W-72. k atop nominal 2 x 8 plank =min. 2-inch thick RhinoBond TPO XHD Plates or Drill- O.C. Tread Safe Plates with RhinoBond Portable -37.5 inch lumber supports insulation) Tec RhinoBond TPO XHD Tread SafeBonding Tool, per manufacturer's published spaced max. 48-inch o.c. Plates through to wood supports instructions. One or more layers, any 1 per 2.0 ftz 116 parts per 4 x 8 ft board) EverGuard TPO bonded to Drill-Tec RhinoBond combination, Drill-Tec XHD Fastener and Drill-Tec Fasteners are 12- and 36-inches from the TPO XHD Plates or Drill-Tec RhinoBond TPO XHD Min. 19/32-inch OSB; 2 ft RhinoBond TPO XHD Plates or Drill- W-73. span preliminarily attached Tec RhinoBond TPO XHD Tread Safe board's long edge and 6-, 18-, 30-, 42-, 54-, Tread Safe Plates with RhinoBond Portable -45.0 (Tread Safe = min. 2-inch Plates 66-, 78- and 90-inches from the board's Bonding Tool, per manufacturer's published thick insulation) shortedge. instructions. Drill-Tec #14 Fastener and Drill-Tec 1 per 2.7 ftz (12 parts per 4 x 8 ft board) EverGuard TPO bonded to Drill-Tec RhinoBond Min. 15/32-inch plywood One or more layers, any RhinoBond TPO XHD Plates or Drill- Fasteners are 6-, 24- and 42-inches from TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W-74. or 1-inch wood plank; 2 ft combination (Tread Safe Tec RhinoBond TPO XHD Tread Safe the board's long edge and 12-, 36-, 60-and Tread Safe Plates with RhinoBond Portable -52.5 span =min. 2-inch) Plates 84-inches from the board's short edge. Bonding Tool, per manufacturer's published instructions. Min. 15/32-inch plywood, min. 19/32-inch (Optional) One or more Drill-Tec #14 (min. 1-inch EverGuard TPO bonded to Drill-Tec RhinoBond OSB or 1-inch wood layers, any combination embedment into joist) and Drill-Tec 36-inch o.c. along wood supports, 24-inch TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W 75 plank over nominal No. 2 (Tread Safe = min. 2-inch RhinoBond TPO XHD Plates or Drill- O.C. Tread Safe Plates with RhinoBond Portable -52.5 wood trusses spaced thick insulation) Tec RhinoBond TPO XHD Tread Safe Bonding Tool, per manufacturer's published max. 24-inch o.c. Plates through to wood supports instructions. Min. 15/32-inch plywood, min. 19/32-inch (Optional) One or more Drill-Tec #14 (min. 1-inch EverGuard TPO bonded to Drill-Tec RhinoBond OSB or 1-inch wood layers, any combination embedment into joist) and Drill-Tec 24-inch o.c. along wood supports, 24-inch TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W-76. plank over nominal No. 2 (Tread Safe = min. 2-inch RhinoBond TPO XHD Plates or Drill- O.C. Tread Safe Plates with RhinoBond Portable -75.0 wood trusses spaced thick insulation) Tec RhinoBond TPO XHD Tread Safe Bonding Tool, per manufacturer's published max. 24-inch o.c. Plates through to wood supports instructions. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NE VIO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 17 of 156 NNEMO I etc. TABLE 1F: ....REROOF (TEAR -OFF) OR RECOVER System Deck Insulation SYSTEM TYPE C-2: PLATE -BONDED ROOF Attachment Roof Cover (Note 156) MDP Fasteners (Note 11) Spacing No. (Note 1) (Note 13) (Psf) Min. 15/32-inch Drill-Tec #14 (min. 1-inch EverGuard TPO bonded to Drill-Tec RhinoBond plywood, min. 19/32-inch (Optional) One or more embedment into joist) and Drill-Tec TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W 77 OSB or 1-inch wood layers, any combination RhinoBond TPO XHD Plates or Drill- 18-inch o.c. along wood supports, 24-inch Tread Safe Plates with RhinoBond Portable -82.5 plank over nominal No. 2 (Tread Safe =min. 2-inch Tec RhinoBond TPO XHD Tread Safe O.C. Bonding Tool, per manufacturer's published wood trusses spaced thick insulation) Plates through to wood supports instructions. max. 24-inch o.c. Min. 19/32-inch Drill-Tec #14 (min. 1-inch EverGuard TPO bonded to Drill-Tec RhinoBond plywood, min. 19/32-inch (Optional) One or more embedment into joist) and Drill-Tec TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W 78 OSB or 1-inch wood layers, any combination RhinoBond TPO XHD Plates or Drill- 9-inch o.c. along wood supports, 24-inch Tread Safe Plates with RhinoBond Portable -90.0 plank over nominal No. 2 (Tread Safe = min. 2-inch Tec RhinoBond TPO XHD Tread Safe O.C. Bonding Tool, per manufacturer's published wood trusses spaced thick insulation) Plates through to wood supports instructions. max. 24-inch o.c. Min. 19/32-inch plywood, min. 19/32-inch One or more layers, any Drill-Tec #14 (min. 1-inch EverGuard TPO bonded to Drill-Tec RhinoBond OSB or 1-inch wood combination, min. 1-inch embedment into joist) and Drill-Tec 9-inch o.c. along wood supports, 24-inch TPO XHD Plates or Drill-Tec RhinoBond TPO XHD W 79. plank over nominal No. 2 (Tread Safe =min. 2-inch RhinoBond TPO XHD Plates or Drill- O.C. Tread Safe Plates with RhinoBond Portable -105.0 wood trusses spaced thick insulation) Tec RhinoBond TPO XHD Tread Safe Bonding Tool, per manufacturers published max. 24-inch o.c. Plates through to wood supports instructions. ABLE IG: ••• rCONSTRUCTION,••• TYPE rINSULATED, MECHANICALLY •RECOVER SYSTEM System Deck Insulation (Note 13) ATTACHED ROOF COVER Roof Cover MDP No. (Note 1) Type Attach Separator Sheet (Optional) (psf) Membrane Fasteners (Note 11) Attachment One or more EverGuard Polymat Separation 6-inch o.c. within 5.5-inch wide laps Min. 19/32-inch plywood or Prelim. Layer (3 oz/yd) or EverGuard EverGuard Drill-Tec #14 Fastener with Drill-Tec 2 in. W-80. 1-inch wood plank; 2 ft span layers, any attached Polymat Cushioning Layer (6 TPO Double Barbed XHD Plates spaced 114.5-inch o.c. and sealed -45.0 combination oz/ydz) with a 1.75-inch heat weld. One or more EverGuard Polymat Separation 6-inch o.c. within 6-inch wide laps W 81. APA rated, 19/32 CAT, 0.578 layers, any Prelim. Layer (3 oz/ydz) or EverGuard EverGuard Drill-Tec XHD with Drill-Tec 2-3/8 in. spaced 54-inch o.c. and sealed with -45.0 in., Exposure 1 OSB combination attached Polymat Cushioning Layer (6 TPO Barbed XHD Plates a 1.5-inch heat weld. oz/yd') One or more EverGuard Polymat Separation 6-inch o.c. within 5-inch wide laps Min. 19/32-inch plywood or Prelim. Layer (3 oz/yd) or EverGuard EverGuard Drill-Tec #14 Fastener with Drill-Tec 2 in. W 82. 1-inch wood plank; 2 ft span layers, any attached Polymat Cushioning Layer (6 TPO Double Barbed XHD Plates spaced 55-inch o.c. and sealed with -52.5 combination oz/ydz) a 1.75-inch heat weld. Min. 15/32-inch plywood, EverGuard Polymat Separation Drill-Tec #14 Fastener with Drill-Tec 2 in. 12-inch o.c. within 6-inch wide laps min. 19/32-inch OSB or 1- One more Prelim. Layer (3 oz/ydz) or EverGuard EverGuard Double Barbed XHD Plates fastened spaced 48-inch o.c. (over wood W-83. inch wood lank over No. 2 P layers, any s, attached Polymat CushioningLayer 6 y ( TPO throughand deck to engage e g g wood joists, joists) sealed with a 1.5-inch -52.5 wood trusses; 2 ft span combination oz/ydz) minimum 1-inch embedment into joist heat weld. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 18 of 156 NNEMO I etc. TABLE 1H: WOOD rREROOF (TEAR -OFF) OR RECOVER System �STEM TYPE Deck Insulation Layer(s) (Note 13) D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Base or Anchor Sheet MDP No. (Note 1) Type Attach Base Fasteners (Note 11) Attach Roof Cover (psf) Min. 15/32-inch One or more GAF StormSafe Anchor Drill-Tec #14 Fastener with Drill-Tec 3" Steel 18-inch o.c. at min. 4-inch lap and EverGuard W-86. plywood or 1-inch layers, any Loose- Sheet (Max. 48-inch Plate or Drill-Tec 3 in. Ribbed Galvalume Plate 18-inch o.c. at two, equally Freedom TPO / -45.0* wood plank; 2 ft combination laid wide) (Flat) or Drill-Tec #14 HD Fastener with Drill-Tec spaced, staggered center rows self adhered span 3" Flat Steel Plate Min. 19/32-inch plywood or inch One or more Loose- GAF StormSafe Anchor Drill-Tec #14 Fastener with Drill-Tec 3 in. 8-inch o.c. at min. 4-inch lap and EverGuard W 87 layers, any Sheet (Max. 48-inch Ribbed Galvalume Plate (Flat) or Drill-Tec #14 8-inch o.c. at two, equally spaced, Freedom TPO / -60.0* , wood plank; 2 ft combination laid wide) HD Fastener with Drill-Tec 3" Flat Steel Plate staggered center rows self adhered span TABLE 1i: ••• rCONSTRUCTION,••• •RECOVER System Deck (Note 1) SYSTEM TYPE E-1: • Separator Sheet • MECHANICALLY ATTACHED ROOF COVER Roof Cover MDP Membrane Fasteners (Note 11) Attachment No. (Optional) (psf) Min. 19/32-inch plywood or 1- EverGuard Polymat Separation Layer (3 Eve EverGuard Drill-Tec #14 Fastener with Drill-Tec 2 in. Double 6-inch o.c. within 5.5-inch wide laps W 88. inch wood plank; 2 ft span oz/yd) or EverGuard Polymat Cushioning TPOwith Barbed XHD Plates spaced 114.5-inch o.c. and sealed -45.0 Layer (6 oz/yd) a 1.75-inch heat weld. APA rated, 19/32 CAT, 0.578 in., EverGuard Polymat Separation Layer (3 EverGuard Drill-Tec XHD with Drill-Tec 2-3/8 in. Barbed XHD 6-inch o.c. within 6-inch wide laps W 89' Exposure 1 OSB oz/yd') or EverGuard Polymat Cushioning TPO Plates spaced 54-inch o.c. and sealed with a -45.0 Layer (6 oz/yd') 1.5-inch heat weld. Min. 19 32-inch I / plywood or 1- EverGuard Polymat Separation Layer (3 EverGuard #14 Fastener with Drill-Tec 2 in. Double 6-inch o.c. within 5-inch wide laps W 90 inch wood plank; 2 ft span oz/yd2) or EverGuard Polymat Cushioning TPO Barbed XHD Plates Barbed spaced 55-inch o.c. and sealed with a -52.5 Layer (6 oz/yd') 1.75-inch heat weld. Min. 15/32-inch plywood, min. 19/32-inch OSB or 1-inch wood EverGuard Polymat Separation Layer (3 EverGuard Drill-Tec #14 Fastener with Drill-Tec 2 in. Double 12-inch o.c. within 6-inch wide laps W 91' plank over No. 2 wood trusses; a oz/yd�) or EverGuard Polymat Cushioning TPO Barbed XHD Plates fastened through deck to engage spaced 48-inch o.c. (over wood joists) -60.0 2 span Layer (6 oz/yd) wood joists, minimum 1-inch embedment into joist and sealed with a 1.5-inch heat weld. 11 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 19 of 156 NNEMO I etc. TABLE 1j: ....REROOF(TEAR-OFF) OR RECOVER EL SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVEI�� System Deck Base Sheet Roof Cover (Note 15) MDP No. j (Note 1) Base Fasteners (Note 11) F Attach Base Cap (Psf) EverGuard Freedom TPO: Min. 19/32-inch GAF StormSafe Anchor Sheet 32 ga., 1-5/8-inch diameter tin 9-inch o.c. at min. 4-inch plywood or 1-inch (Max. 40-inch wide or lapped to caps with 11 ga. annular ring lap and 9-inch o.c. at two, EverGuard Freedom W-94' wood lank; 2 ft P produce max. 36-inch wide la P P- shank nails new or reroof only; ( Y equally spaced, staggered q Y P gg None TPO -45.0 span to -lap spacing) no recover) center rows Min. 15/32-inch 32 ga., 1-5/8-inch diameter tin 6-inch o.c. at min. 4-inch w 95 plywood or 1-inch GAF StormSafe Anchor Sheet caps with 12 ga. x 1.25-inch lap and 6-inch o.c. at two, None EverGuard Freedom -45.0* wood plank; 2 ft (Max. 48-inch wide) annular ring shank nails (new or equally spaced, staggered TPO span reroof only; no recover) center rows Min. 15/32-inch Drill-Tec #14 Fastener with Drill- 18-inch o.c. at min. 4-inch plywood or 1-inch GAF StormSafe Anchor Sheet Tec 3 in. Ribbed Galvalume lap and 18-inch o.c. at two, EverGuard Freedom W 96' wood plank; 2 ft (Max. 48-inch wide) Plate (Flat) or Drill-Tec #14 HD equally spaced, staggered None TPO -45.0* span Fastener with Drill-Tec 3" Flat Steel Plate center rows Min. 19/32-inch Drill-Tec #14 Fastener with Drill- 8-inch o.c. at min. 4-inch plywood or 1-inch GAF StormSafe Anchor Sheet Tec 3 in. Ribbed Galvalume lap and 8-inch o.c. at two, EverGuard Freedom w 97' wood plank; 2 ft (Max. 48-inch wide) Plate (Flat) or Drill-Tec #14 HD equally spaced, staggered None TPO -67.5* span Fastener with Drill-Tec 3" Flat Steel Plate center rows Drill-Tec #12 or #14 Fastener Min. 19/32-inch GAF StormSafe Anchor Sheet with Drill-Tec 3" Steel Plates or 8-inch o.c. at min. 4-inch plywood or 1-inch (Max. 40-inch wide or lapped to Drill-Tec 3 in. Ribbed Galvalume lap and 8-inch o.c. at EverGuard Freedom W-98' wood plank; 2 ft produce max. 36-inch wide lap- Plate (Flat) or Drill-Tec #14 HD three, equally spaced, None TPO 10�5.0 span to -lap spacing) Fastener with Drill-Tec 3" Flat staggered center rows Steel Plate Hybrid System: NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMo ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 20 of 156 NNEMO I etc. TABLE 1j: ....REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY ATTACHED BASE Base Sheet BONDED ROOF Roof Cover (Note 15) MDP No. (Note 1) Base Fasteners (Note 11) Attach Base Cap (psf) GAFGLAS #75 Base Sheet, Tri-Ply (Optional) One or two plies Ruberoid 20 Min. 15/32-inch #75 Base Sheet, GAFGLAS #80 32 ga., 1-5/8-inch dia. tin caps 8-inch o.c. at min. 4-inch Smooth, Ruberoid Mop Smooth, Ruberoid EverGuard TPO W-99' plywood or 1-inch Ultima Base Sheet, GAFGLAS with 12 ga. annular ring shank laps and 8-inch o.c. in two, Mop Smooth 1.5 or Ruberoid Mop Plus Fleece -Back -45.0 wood plank; 2 ft Stratavent Nailable Venting Base nails (new or reroof only; no equally spaced, staggered Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot span Sheet, Ruberoid 20 Smooth recover) center rows Smooth or Ruberoid HW Smooth, torch- apshalt applied (Optional) One or two plies Ruberoid 20 Min. 19/32-inch GAFGLAS #80 Ultima Base Sheet, 32 ga., 1-5/8-inch dia. tin caps 9-inch o.c. at min. 4-inch Smooth, Ruberoid Mop Smooth, Ruberoid EverGuard TPO W-100. plywood or 1-inch GAFGLAS Stratavent Nailable with 12 ga. annular ring shank laps and 9-inch o.c. in two, Mop Smooth 1.5 or Ruberoid Mop Plus Fleece -Back -45.0 wood plank; 2 ft Venting Base Sheet, Ruberoid 20 nails (new or reroof only; no equally spaced, staggered Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot span Smooth recover) center rows Smooth or Ruberoid HW Smooth, torch- apshalt applied GAFGLAS #75 Base Sheet, Tri-Ply (Optional) One or two plies Ruberoid 20 2 Min. 15/32-inch #75 Base Sheet, GAFGLAS #80 32 ga., 1-5/8-inch dia. tin caps 6-inch o.c. at min. 4-inch Smooth, Ruberoid Mop Smooth, Ruberoid EverGuard TPO W-101. plywood 1-inch Ultima Base Sheet, GAFGLAS with 12 ga. annular ring shank laps and 6-inch o.c. in two, Mop Smooth 1.5 or Ruberoid Mop Plus Fleece -Back -52.5 wood plank; 2 ft Stratavent Nailable Venting Base nails (new or reroof only; no equally spaced, staggered Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot span Sheet, Ruberoid 20 Smooth recover) center rows Smooth or Ruberoid HW Smooth, torch- apshalt applied GAFGLAS #75 Base Sheet, Tri-Ply (Optional) One or two plies Ruberoid 20 Min. 15/32-inch #75 Base SheetGAFGLAS #80 16-inch o.c. at 4-inch laps Smooth, Ruberoid Mop Smooth, Ruberoid EverGuard TPO W-102. plywood or 1-inch , Ultima Base Sheet, GAFGLAS Note 2 (#14 ONLY) and 16-inch o.c. in two, Mop Smooth 1.5 or Ruberoid Mop Plus Fleece -Back -52.5 wood plank; 2 ft Stratavent Nailable Venting Base equally spaced, staggered Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot span Sheet, Ruberoid 20 Smooth center rows Smooth or Ruberoid HW Smooth, torch- apshalt applied GAFGLAS #75 Base Sheet, Tri-Ply (Optional) One or two plies Ruberoid 20 Min. 15/32-inch #75 Base Sheet, GAFGLAS #80 12-inch o.c. at 4-inch laps Smooth, Ruberoid Mop Smooth, Ruberoid EverGuard TPO W-103. plywood or 1-inch Ultima Base Sheet, GAFGLAS Note 2 (#14 ONLY) and 12-inch o.c. in two, Mop Smooth 1.5 or Ruberoid Mop Plus Fleece -Back -60.0 wood plank; 2 ft Stratavent Nailable Venting Base equally spaced, staggered Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot span Sheet, Ruberoid 20 Smooth center rows Smooth or Ruberoid HW Smooth, torch- apshalt applied (Optional) One or two plies Ruberoid 20 Min. 19/32-inch GAFGLAS #80 Ultima Base Sheet, 32 ga., 1-5/8-inch dia. tin caps 8-inch the 4-inch lap Smooth, Ruberoid Mop Smooth, Ruberoid EverGuard TPO W-104. plywood or 1-inch GAFGLAS Stratavent Nailable with 12 ga. annular ring shank and 8-inch o. o.c. in three Mop Smooth 1.5 or Ruberoid Mop Plus Fleece -Back -75.0 wood plank; 2 ft Venting Base Sheet, Ruberoid 20 nails (new or reroof only; no staggered center rows Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot span Smooth recover) Smooth or Ruberoid HW Smooth, torch- apshalt applied NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 21 of 156 NNEMO I etc. TABLE 1j: ....REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY ATTACHED BASE Base Sheet BONDED ROOF Roof Cover (Note 15) MDP No. (Note 1) Base Fasteners (Note 11) Attach Base Cap (psf) Min. 19/32-inch GAFGLAS #75 Base Sheet, Tri-Ply 32 ga., 1-5/8-inch dia. tin caps 4-inch o.c. at min. 2-inch Ruberoid 20 Smooth, Ruberoid Mop Smooth EverGuard TPO plywood or 1-inch #75 Base Sheet, GAFGLAS #80 with 11 ga. annular ring shank laps and 4-inch o.c. at four 1.5, Ruberoid Mop Smooth, Ruberoid Mop Fleece -Back W-105. wood plank; 2 ft Ultima Base Sheet, GAFGLAS nails (new or reroof only; no (4), equally spaced, Plus Smooth /hot asphalt or Ruberoid HW Membrane in hot -97.5 span Stratavent Nailable Venting Base recover) staggered center rows Smooth, Ruberoid HW 25 Smooth / torch- apshalt Sheet, Ruberoid 20 Smooth applied GAFGLAS #75 Base Sheet, Tri-Ply (Optional) One or two plies Ruberoid 20 Min. 15/32-inch #75 Base Sheet, GAFGLAS #80 8-inch o.c. at 4-inch laps Smooth, Ruberoid Mop Smooth, Ruberoid EverGuard TPO W-106. plywood or 1-inch Ultima Base Sheet , GAFGLAS Note 2 (#14 ONLY) and 8-inch o.c. in three, Mop Smooth 1.5 or Ruberoid Mop Plus Fleece -Back 97.5 wood plank; 2 ft Stratavent Nailable Venting Base equally spaced, staggered Smooth in hot asphalt or Ruberoid HW 25 Membrane in hot span Sheet, Ruberoid 20 Smooth center rows Smooth or Ruberoid HW Smooth, torch- apshalt applied Min. 15/32-inch GAFGLAS #75 Base Sheet, Tri-Ply 32 ga., 1-5/8-inch dia. tin caps 8-inch o.c. at min. 4-inch One or two plies Ruberoid 20 Smooth, EverGuard TPO Fleece -Back plywood or 1-inch #75 Base Sheet, GAFGLAS #80 with 12 ga. annular ring shank laps and 8-inch o.c. in two, Ruberoid Mop Smooth, Ruberoid Mop Membrane in GAF 2- W-107. wood plank; 2 ft Ultima Base Sheet, GAFGLAS nails (new or reroof only; no equally spaced, staggered Smooth 1.or Ruberoid Mop Plus Smooth in part (spatter), LRF-XF -45.0 span Stratavent Nailable Venting Base recover) center rows hot asphaltt or Ruberoid HW 25 Smooth or (spatter) or OB500 Sheet, Ruberoid 20 Smooth Ruberoid HW Smooth, torch -applied (spatter) One or two plies Ruberoid 20 Smooth, EverGuard TPO Min. 19/32-inch GAFGLAS #80 Ultima Base Sheet, 32 ga., 1-5/8-inch dia. tin caps 9-inch o.c. at min. 4-inch Ruberoid Mop Smooth, Ruberoid Mop Fleece -Back W-108. plywood or 1-inch GAFGLAS Stratavent Nailable with 12 ga. annular ring shank laps and 9-inch o.c. in two, Smooth 1.5 or Ruberoid Mop Plus Smooth in Membrane in GAF 2- -45.0 wood plank; 2 ft Venting Base Sheet, Ruberoid 20 nails (new or reroof only; no equally spaced, staggered hot asphalt or Ruberoid HW 25 Smooth or part (spatter), LRF-XF span Smooth recover) center rows Ruberoid HW Smooth, torch -applied (spatter) or OB500 (spatter) Min. 15/32-inch Tri-Ply GAFGLAS #75 Base Sheet,#80 32 ga., 1-5/8-inch dia. tin caps 6-inch o.c. at min. 4-inch One or two plies Ruberoid 20 Smooth, EverGuard TPO Fleece -Back plywood or 1-inch #75 Base Sheet, GAFGLAS with 12 ga. annular ring shank laps and 6-inch o.c. in two, Ruberoid Mop Smooth, Ruberoid Mop Membrane in GAF 2- W-109. wood plank; 2 ft Ultima Base Sheet, GAFGLAS nails (new or reroof only; no equally spaced, staggered Smooth 1.t or Ruberoid Mop Plus Smooth in part (spatter), LRF-XF -52.5 span Stratavent Nailable Venting Base recover) center rows hot asphalt or Ruberoid HW 25 Smooth or (spatter) or OB500 Sheet, Ruberoid 20 Smooth Ruberoid HW Smooth, torch -applied (spatter) Min. 15/32-inch GAFGLAS #75 Base Sheet, Tri-Ply 16-inch o.c. at 4-inch laps One or two plies Ruberoid 20 Smooth, EverGuard TPO Fleece -Back plywood or 1-inch #75 Base Sheet, GAFGLAS #80 and 16-inch o.c. in two, Ruberoid Mop Smooth, Ruberoid Mop Membrane in GAF 2- W-110. wood plank; 2 ft Ultima Base Sheet, GAFGLAS Note 2 (#14 ONLY) equally spaced, staggered Smooth 1.5 or Ruberoid Mop Plus Smooth in part (spatter), LRF-XF -52.5 span Stratavent Nailable Venting Base center rows hot asphalt or Ruberoid HW 25 Smooth or (spatter) or OB500 Sheet, Ruberoid 20 Smooth Ruberoid HW Smooth, torch -applied (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMo ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 22 of 156 NNEMO I etc. TABLE 1j: ....REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY ATTACHED BASE Base Sheet BONDED ROOF Roof Cover (Note 15) MDP No. (Note 1) Base Fasteners (Note 11) Attach Base Cap (psf) Min. 15/32-inch GAFGLAS #75 Base Sheet, Tri-Ply 12-inch o.c. at 4-inch laps One or two plies Ruberoid 20 Smooth, EverGuard TPO Fleece -Back plywood or 1-inch #75 Base Sheet, GAFGLAS #80 and 12-inch o.c. in two, Ruberoid Mop Smooth, Ruberoid Mop Membrane in GAF 2- W-111. wood plank; 2 ft Ultima Base Sheet, GAFGLAS Note 2 (#14 ONLY) equally spaced, staggered Smooth 1.5 or Ruberoid Mop Plus Smooth in Part (spatter), LRF-XF -60.0 span Stratavent Nailable Venting Base center rows hot asphalt or Ruberoid HW 25 Smooth or (spatter) or OB500 Sheet, Ruberoid 20 Smooth Ruberoid HW Smooth, torch -applied (spatter) One or two plies Ruberoid 20 Smooth, EverGuard TPO Min. 19/32-inch GAFGLAS #80 Ultima Base Sheet, 32 ga., 1-5/8-inch dia. tin caps 8-inch o.c. at the 4-inch lap Ruberoid Mop Smooth, Ruberoid Mop Fleece -Back W-112. plywood or 1-inch GAFGLAS Stratavent Nailable with 12 ga. annular ring shank and 8-inch o.c. in three Smooth 1.5 or Ruberoid Mop Plus Smooth in Membrane in GAF 2- -75.0 wood plank; 2 ft Venting Base Sheet, Ruberoid 20 nails (new or reroof only; no staggered center rows hot asphalt or Ruberoid HW 25 Smooth or Part (spatter), LRF-XF span Smooth recover) Ruberoid HW Smooth, torch -applied (spatter) or OB500 (spatter) Min. 19/32-inch GAFGLAS #75 Base Sheet, Tri-Ply 32 ga., 1-5/8-inch dia. tin caps 4-inch o.c. at min. 2-inch Ruberoid 20 Smooth, Ruberoid Mop Smooth EverGuard TPO plywood or 1-inch #75 Base Sheet, GAFGLAS #80 with 11 ga. annular ring shank laps and 4-inch o.c. at four 1.5, Ruberoid Mop Smooth, Ruberoid Mop Fleece -Back W-113. wood plank; 2 ft Ultima Base Sheet, GAFGLAS nails (new or reroof only; no (4), equally spaced, Plus Smooth / hot asphalt or Ruberoid HW Membrane in GAF 2- -97.5 span Stratavent Nailable Venting Base recover) staggered center rows Smooth, Ruberoid HW 25 Smooth /torch- Part (spatter) or LRF- Sheet, Ruberoid 20 Smooth applied XF (spatter) Min. 15/32-inch GAFGLAS #75 Base Sheet, Tri-Ply 8-inch o.c. at 4-inch laps One or two plies Ruberoid 20 Smooth, EverGuard TPO plywood or 1-inch #75 Base Sheet, GAFGLAS #80 and inch in three, Ruberoid Mop Smooth, Ruberoid Mop Fleece -Back W-114. wood plank; 2 ft Ultima Base Sheet, GAFGLAS Note 2 (#14 ONLY) , staggered equally spaced, Smooth 1.5 or Ruberoid Mop Plus Smooth in Membrane in GAF 2- -97.5 Stratavent Nailable Venting Base hot asphalt or Ruberoid HW 25 Smooth or Part (spatter) or LRF- span Sheet, Ruberoid 20 Smooth center rows Ruberoid HW Smooth, torch -applied XF (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 23 of 156 NNEMO I etc. TABLE 2A: STEEL •REROOF (TEAR -OFF) System Deck SYSTEM TYPE A-1: BONDED INSULATION, Insulation BONDED ROOF Roof Cover (Note 15) MDP No. (Note 1) Type Attach (Notes 6,7,9) (Psf) EverGuard TPO: S-1. Min. 22 ga., type B, Grade 40 steel Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M or OB500, 6" o.c. EverGuard TPO / TPO QSA or TPO QSA LV50 -82.5 S-2. Min. 22 ga., type B, Grade 40 steel Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M or OB500, 6" o.c. EverGuard TPO / #1121, TPO 6-Square, TPO 3-Square, WB181 -120.0 EverGuard TPO Fleece -Back Membrane in Spatter Applications: S-3. Min. 22 ga., type B, Grade 40 steel Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M or OB500, 6" o.c. EverGuard TPO Fleece -Back Membrane / GAF 2-Part (spatter), LRF- _120.0 XF (spatter) or OB500 (spatter) TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEIVITYPEB-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,a) EverGuard Freedom TPO: Min. 22 ga., Type B, Grade 1 per Min. 0.5-inch EnergyGuard RH HD Polyiso LRF-M or EverGuard Freedom TPO / self S-4. 33 steel or min. 2,500 psi Min. 1.5-inch EnergyGuard RH Note 2 2.0 W Insulation, EnergyGuard HD Polyiso Insulation, OB500 adhered -37.5* structural concrete EnergyGuard HD Plus Polyiso Insulation Min. 22 ga., Type B, Grade 1 per Min. 0.5-inch EnergyGuard RH HD Polyiso LRF-M LRF-M or EverGuard Freedom TPO self S-5. 33 steel or min. 2,500 psi Min. 2-inch EnergyGuard RH Note 2 2 9 ft2 Insulation, EnergyGuard HD Polyiso Insulation, adhered -37.5* structural concrete EnergyGuard HD Plus Polyiso Insulation Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard RA, 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part EverGuard Freedom TPO/ self S-6. 33 steel or min. 2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 2.0 ft2 Board or OB500 adhered -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard RA, 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part EverGuard Freedom TPO/ self S-7. 33 steel min. 2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 4.0 ft2 Board or OB500 adhered -45.0* l structural concrete Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-Part, EverGuard Freedom TPO/ self S-8. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 insulation followed by Min. 0.25-inch LRF-M or adhered -45.0* structural concrete SECUROCK Gypsum -Fiber Roof Board OB500 Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-Part, EverGuard Freedom TPO/ self S-9. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4 .0 ft� insulation followed by Min. 0.25-inch LRF-M or adhered -45.0* structural concrete SECUROCK Gypsum -Fiber Roof Board OB500 Min. 22 ga., Type B, Grade Min EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-Part, EverGuard Freedom TPO/ self 5-10. 33 steel or min. 2,500 psi Insulation, E Insulation, EnergyGuard Ultra Note 2 2.0 ft2 insulation LRF-M or adhered -45.0* structural concrete OB500 Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 1 per Additional optional layers, min. 0.5-inch base GAF 2-Part, EverGuard Freedom TPO/ self 5-11. 33 steel or min. 2,500 psi InsulationEnergyGuard Ultra , Note 2 ft2 insulation LRF-M or adhered -45.0* structural concrete OB500 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMD ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 24 of 156 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer MDP Type Fasten Attach Type Attach No. (Note 1) Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,8) Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part, EverGuard Freedom TPO/ self 5-12. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH Note 2 2.0 ft2 Board LRF-M or adhered -52.5 structural concrete OB500 Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard RA 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part EverGuard Freedom TPO/ self 5-13. 33 steel or min. 2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 1.6 ft2 Board or OB500 adhered -60.0 structural concrete Min. 22 ga., Type B, Grade Min ch EnergyGuard RA or 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard Freedom TPO/ self 5-14. 33 steel or min. 2,500 psi EnergyGuard RH Note 2 2.0 ft2Board LRF-XF adhered _45.0* structural concrete Min. 22 ga., Type B, Grade Min EnergyGuard RA or 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard Freedom TPO/ self 5-15. 33 steel or min. 2,500 psi G EnergyGuard RH Note 2 4.0 ft2Board LRF-XF adhered -45.0* structural concrete Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 pe Additional optional layers, min. 0.5-inch base EverGuard Freedom TPO/ self 5-16. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2SECUROCK insulation followed by Min. 0.25-inch LRF-XF adhered -45.0* structural concrete Gypsum -Fiber Roof Board Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard Freedom TPO/ self 5-17. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4 .0 ft� insulation followed by Min. 0.25-inch LRF-XF adhered -45.0* structural concrete SECUROCK Gypsum -Fiber Roof Board Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard Freedom TPO/ self 5-18. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 insulation LRF-XF adhered -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard Freedom TPO/ self 5-19. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4.0 ft2 insulation LRF-XF adhered -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard Freedom TPO/ self 5-20. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH Note 2 2.0 ft2 Board LRF-XF adhered -52.5 structural concrete Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard RA or 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard Freedom TPO/ self 5-21. 33 steel or min. 2,500 psi EnergyGuard RH Note 2 1.6 ft2Board LRF-XF adhered -60.0 structural concrete EverGuard TPO: Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard RA or 1 per EverGuard TPO / #1121, TPO 3- 5-22. 33 steel or min. 2,500 psi EnergyGuard RN Note 2 2.0 ft� Additional layers of base insulation Hot asphalt Square, WB181 -45.0* structural concrete Min. 22ga., Type B, Grade Min. 2-inch EnergyGuard RA or 1 per EverGuard TPO / #1121, TPO 3- 5-23. el 33 steel min. 2,500 psi EnergyGuard RN Note 2 4 0 ft2 Additional layers of base insulation Hot asphalt Square, WB181 -45.0* structural concrete NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 25 of 156 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer MDP Type Fasten Attach Type Attach No. (Note 1) Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,8) Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard RA, 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / #1121, TPO 6- 5-24. 33 steel or min. 2,500 psi EnergyGuard RN, EnergyGuard RH Note 2 3.2 ft2 Gypsum -Fiber Roof Board OB500 Square, TPO 3-Square, WB181 -37.5* structural concrete Min. 22 ga., Type B, Grade 1 per Min. 0.5-inch EnergyGuard RH HD Polyiso LRF-M or EverGuard TPO / #1121, TPO 6- 5-25. 33 steel or min. 2,500 psi Min. 1.5-inch EnergyGuard RH Note 2 2.0 ft2 Insulation, EnergyGuard HD Polyiso Insulation, OB500 Square, TPO 3-Square, WB181 -37.5* structural concrete EnergyGuard HD Plus Polyiso Insulation Min. 22 ga., Type B, Grade 1 per per Min. 0.5-inch EnergyGuard RH HD Polyiso F-M LRF-M or EverGuard EverGuard TPO / #1121, TPO 6- , TPO TTPO 5-26. 33 steel or min. 2,500 psi Min. 2-inch EnergyGuard RH Note 2 2 9 Insulation, EnergyGuard HD Polyiso Insulation, OB500 Square, 3-Square, -37.5* structural concrete EnergyGuard HD Plus Polyiso Insulation Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso 1 per One or more layers of Base Insulation or min. GAF 2-Part EverGuard TPO / #1121, TPO 3- 5-27. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 0.5-inch thick DensDeck or OB500 Square -45.0* structural concrete Min. 22 ga., Type B, Grade 1 per One or more layers, min. 1.5-inch EnergyGuard GAF 2-Part EverGuard TPO / #1121, TPO 3- 5-28. 33 steel or min. 2,500 psi Min. 0.5-inch DensDeck Note 2 2.0 ft2 Polyiso Insulation, EnergyGuard Ultra or OBS00 Square, WB181 _45.0* structural concrete Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso 5-29. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra, Note 2 1 per Min. 0.5-inch Fiber Base HD1, Fiber Base HD6 OB500 EverGuard TPO / WB181 -45.0* structural concrete EnergyGuard RA, EnergyGuard RN, 2 0 ft� EnergyGuard RH Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard RA, 1 per Min. 0.5-inch Structodek High Density EverGuard TPO / #1121, TPO 6- 5-30. 33 steel or min. 2,500 psi EnergyGuard RN, EnergyGuard RH Note 2 2.0 ft2 Fiberboard Roof Insulation OB500 Square, TPO 3-Square -45.0* structural concrete Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base LRF-M or EverGuard TPO / #1121, TPO 6- 5-31. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2ft� insulation followed by Min. 0.5-inch Structodek OB500 Square, TPO 3-Square -45.0* structural concrete High Density Fiberboard Roof Insulation Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base or EverGuard / TPO 6- 5-32. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4.0 ftz insulation followed by Min. 0.5-inch Structodek OB500 OB500 3- 3-Sq#112uare Square, TPO 3-Square _45.0* structural concrete High Density Fiberboard Roof Insulation Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard RA, 1 per Min. 0.25-inch DensDeck Prime or SECUROCK GAF 2-Part EverGuard TPO / #1121, TPO 6- 5-33. 33 steel or min. 2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 2.0 ft2 Gypsum -Fiber Roof Board or OB500 Square, TPO 3-Square, WB181 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard RA, 1 per Min. 0.25-inch DensDeck Prime or SECUROCK GAF 2-Part EverGuard TPO / #1121, TPO 6- 5-34. 33 steel or min. 2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 4.0 ft2 Gypsum -Fiber Roof Board or OB500 Square, TPO 3-Square, WB181 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-Part, EverGuard TPO / #1121, TPO 6- 5-35. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 insulation followed by Min. 0.25-inch DensDeck LRF-M or Square, TPO 3-Square, WB181 -45.0* structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board OB500 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 26 of 156 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer MDP Type Fasten Attach Type Attach No. (Note 1) Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,8) Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-Part, EverGuard TPO / #1121, TPO 6- 5-36. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4 structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board OB500 Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-Part, EverGuard TPO / #1121, TPO 6- 5-37. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 insulation LRF-M or Square, TPO 3-Square, WB181 -45.0* structural concrete OB500 Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-PaPa EverGuard TPO / #1121, TPO 6- 5-38. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4.0 ft2 insulation or LRF-M or Square, TPO 3-Square, WB181 -45.0* structural concrete OB500 Min. 22 ga., Type B, Grade Min EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part, EverGuard TPO 6- / #1123-Square 5-39. 33 steel or min. 2,500 psi Insulation, Insulation, EnergyGuard RH Note 2 2.0 ft2 Board LRF-M or 3- Square, TPO 3-Square -52.5 structural concrete OB500 Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard RA, 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part EverGuard TPO / #1121, TPO 6- 5-40. 33 steel or min. 2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 1.6 ft2 Board or OB500 Square, TPO 3-Square, WB181 -60.0 structural concrete Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part EverGuard TPO / #1121, TPO 6- 5-41. steelorl min. 2,500 psi Insulation, EnergyGuard RA, Note 2 1.3 ft2 Board or OB500 Square, TPO 3-Square, WB181 -60.0 structural t concrete EnergyGuard RH or EnergyGuard RN Min. 22 ga., Type B, Grade Min. 3-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof OB500, 4- 5-42. 80 steel or min. 2,500 psi Insulation or EnergyGuard Ultra Note 2 1.0 ft2 Board inch o.c. EverGuard TPO / #1121 -120.0 structural concrete Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / #1121, TPO 6- 5-43. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA or Note 2 1.3 ft2 Board LRF-M Square, TPO 3-Square, WB181 -60.0 structural concrete EnergyGuard RN Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard RA or 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / #1121, TPO 6- 5-44. 33 steel or min. 2,500 psi EnergyGuard RH Note 2 2.0 ft2 Gypsum -Fiber Roof Board LRF-XF Square, TPO 3-Square, WB181 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard RA or 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / #1121, TPO 6- 5-45. 33 steel or min. 2,500 psi EnergyGuard RH Note 2 4.0 ft2 Gypsum -Fiber Roof Board LRF-XF Square, TPO 3-Square, WB181 _45.0 structural concrete* Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO / #1121, TPO 6- 5-46. 33 steel or min. 2,500 psi InsulationEnergyGuard Ultra , Note 2 2 0 ft� insulation followed by Min. 0.25-inch DensDeck LRF-XF Square, TPO 3-Square, W6181 -45.0* structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per per Additional optional layers, min. 0.5-inch base EverGuard EverGuard TPO / #1121, TPO 6- , TPO TTPO 5-47. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4 0 ft2 insulation followed by Min. 0.25-inch DensDeck LRF-XF Square, 3-Square, -45.0* structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 27 of 156 NNEMO I etc. TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer MOP Type Fasten Attach Type Attach No. (Note 1) Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,8) Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO / #1121, TPO 6- 5-48. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 insulation LRF-XF Square, TPO 3-Square, WB181 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO / #1121, TPO 6- 5-49. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4.0 ft2 insulation LRF-XF Square, TPO 3-Square, WB181 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / #1121, TPO 6- 5-50. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH Note 2 2.0 ft2 Board LRF-XF Square, TPO 3-Square -52.5 structural concrete Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard RA or 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / #1121, TPO 6- 5-51. 33 steel or min. 2,500 psi EnergyGuard RH Note 2 1.6 ft2 Board LRF-XF Square, TPO 3-Square, W6181 _60.0 structural concrete Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / #1121, TPO 6- 5-52. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA or Note 2 1.3 ft2 Board LRF-XF Square, TPO 3-Square, WB181 -60.0 structural concrete I EnergyGuard RH EverGuard TPO / EverGuard TPO Quick Spray or EverGuard TPO Quick Spray LV SO: Min. 22 ga., Type B, Grade 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / TPO QSA or 5-53. 33 steel or min. 2,500 psi Min. 1.5-inch EnergyGuard RA Note 2 3.2 ft2 Gypsum -Fiber Roof Board OB500 TPO QSA LV50 -37.5* structural concrete Min. 22 ga., Type B, Grade 1 per One or more layers, min. 1.5-inch EnergyGuard GAF 2-Part EverGuard TPO / TPO QSA or 5-54. 33 steel or min. 2,500 psi Min. 0.5-inch DensDeck Note 2 2.0 ft2 Polyiso Insulation or OB500 TPO QSA LV50 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard RA, 1 per Min. 0.25-inch DensDeck Prime or SECUROCK GAF 2-Part EverGuard TPO / TPO QSA or 5-55. 33 steel or min. 2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 2.0 ft2 Gypsum -Fiber Roof Board or OB500 TPO QSA LV50 _q5.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard RA, 1 per Min. 0.25-inch DensDeck Prime or SECUROCK GAF 2-Part EverGuard TPO / TPO QSA or 5-56. 33 steel or min. 2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 4.0 ft2 Gypsum -Fiber Roof Board or OB500 TPO QSA LV50 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-Part, EverGuard TPO / TPO QSA or 5-57. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft' insulation followed by Min. 0.25-inch DensDeck LRF-M or TPO QSA LV50 -45.0* structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board OB500 Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-Part, Eve EverGuard TPO / TPO QSA or 5-58. 33 steel or min. 2,500 psi InsulationEnergyGuard Ultra , Note 2 4 0 fti insulation followed by Min. 0.25-inch DensDeck LRF-M or TPOQSA LV50 -45.0* structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board OB500 Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-Part, EverGuard TPO / TPO QSA or 5-59. 33 steel or min. 2,500 psi Insulation Note 2 2.0 ft2 insulation LRF-M or TPO QSA LV50 -45.0* structural concrete OB500 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 28 of 156 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer MDP Type Fasten Attach Type Attach No. (Note 1) Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,8) Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-Part, EverGuard TPO / TPO QSA or 5-60. 33 steel or min. 2,500 psi Insulation Note 2 q.0 ft2 insulation LRF-M or TPO QSA LV50 -45.0* structural concrete OB500 Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part , EverGuard TPO / TPO QSA or 5-61. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH Note 2 2.0 ft2 Board LRF-M or TPO QSA LV50 -52.5 structural concrete OB500 Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard RA, 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part EverGuard TPO / TPO QSA or 5-62. 33 steel or min. 2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 1.6 ft2 Board or OB500 TPO QSA LV50 -60.0 structural concrete Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part EverGuard TPO / TPO QSA or 5-63. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA, Note 2 1.3 ft2 Board or OBS00 TPO QSA LV50 -60.0 structural concrete EnergyGuard RH or EnergyGuard RN Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / TPO QSA or 5-64. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA or Note 2 1.3 ft2 Board LRF-M TPO QSA LV50 -60.0 structural concrete EnergyGuard RN Min. 22 ga., Type B, Grade Min. 3-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof OB500, 4- EverGuard TPO / TPO QSA or 5-65. 80 steel or min. 2,500 psi Insulation or EnergyGuard Ultra Note 2 1.0 ft2 Board inch o.c. TPO QSA LV50 82.5 structural concrete Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard RA or 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / TPO QSA or 5-66. 33 steel or min. 2,500 psi EnergyGuard RH Note 2 2.0 ft2 Gypsum -Fiber Roof Board LRF-XF TPO QSA LV50 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard RA or 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / TPO QSA or 5-67. 33 steel or min. 2,500 psi EnergyGuard RH Note 2 4.0 ft2 Gypsum -Fiber Roof Board LRF-XF TPO QSA LV50 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO / TPO QSA or 5-68. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 insulation followed by Min. 0.25-inch DensDeck LRF-XF TPO QSA LV50 -45.0* structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO / TPO QSA or 5-69. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4.0 ft z insulation followed by Min. 0.25-inch DensDeck LRF-XF TPO QSA LV50 _45.0* structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO / TPO QSA or 5-70. 33 steel or min. 2,500 psi Insulation Note 2 2.0 ftz insulation LRF-XF TPO QSA LV50 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO / TPO QSA or 5-71. steel min. 2,500 psi Insulation Note 2 4.0 ft2 insulation LRF-XF TPO QSA LV50 -45.0* structural l structural concrete NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 29 of 156 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer MDP Type Fasten Attach Type Attach No. (Note 1) Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,8) Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / TPO QSA or 5-72. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH Note 2 2.0 ft2 Board LRF-XF TPO QSA LV50 -52.5 structural concrete Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard RA or 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / TPO QSA or 5-73. 33 steel or min. 2,500 psi EnergyGuard RH Note 2 1.6 ft2 Board LRF-XF TPO QSA LV50 -60.0 structural concrete Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 perMin. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / TPO QSA or 5-74. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA or Note 2 1.3 Board LRF-XF TPO QSA LV50 -60.0 structural concrete EnergyGuard RH EverGuard TPO / FastLayn TPO Adhesive: Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Min. 0.5-inch EnergyGuard HD Polyiso GAF 2-Part, hot asphalt, EverGuard TPO / FastLayn TPO 5-75. steelorl min. 2,500 psi Insulation, EnergyGuard Ultra Polyiso Note 2 1.8 ft2 Insulation LRF-M or Adhesive -30.0 t concrete structural Insulation OB500 Min. 22 ga., Type B, Grade 1 per EverGuard TPO / FastLayn TPO 5-76. 33 steel or min. 2,500 psi Min. 1.5-inch EnergyGuard RA Note 2 2 0 ft2 Additional layers of base insulation hot asphalt Adhesive -45.0* structural concrete Min. 22 ga., Type B, Grade 1 1 per EverGuard TPO / FastLayn TPO 5-77. 33 steel or min. 2,500 psi Min. 2-inch EnergyGuard RA Note 2 4.ft2 Additional layers of base insulation hot asphalt Adhesive -45.0* structural concrete Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard RA, 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / FastLayn TPO 5-78. 33 steel or min. 2,500 psi EnergyGuard RN, EnergyGuard RH Note 2 3.2 ftz Gypsum -Fiber Roof Board OB500 Adhesive -37.5* structural concrete Min. 22 ga., Type B, Grade 1 per Min. 0.5-inch EnergyGuard HD Polyiso LRF-M or EverGuard TPO / FastLayn TPO 5-79. 33 steel or min. 2,500 psi Min. 1.5-inch EnergyGuard RH Note 2 2.0 ft' Insulation OB500 Adhesive -37.5* structural concrete Min. 22ga., Type B, Grade 1 per Min. 0.5-inch EnergyGuard HD Polyiso LRF-M or EverGuard TPO / FastLayn TPO 5-80. steelel min. 2,500 psi Min. 2-inch EnergyGuard RH Note 2 2.9 ft2 Insulation OB500 Adhesive -37.5* t st structural l concrete s Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso 1 per GAF 2-Part EverGuard TPO /FastLayn TPO 5-81. 33 steel or min. 2,500 psi Insulation Note 2 a 2.0 ft2 Additional layers of base insulation or OB500 Adhesive -45.0* structural concrete Min. 22 ga., Type B, Grade 1 per One or more layers, min. 1.5-inch EnergyGuard GAF 2-Part EverGuard TPO / FastLayn TPO 5-82. 33 steel or min. 2,500 psi Min. 0.5-inch DensDeck Note 2 2.0 ft2 Polyiso Insulation or OB500 Adhesive -45.0* structural concrete Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard RA, 1 per Min. 0.25-inch DensDeck Prime or SECUROCK GAF 2-Part EverGuard TPO / FastLayn TPO 5-83. 33 steel or min. 2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 2.0 ft2Gypsum-Fiber Roof Board or OB500 Adhesive -45.0* structural concrete NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 30 of 156 NNEMO I etc. TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer MDP Type Fasten Attach Type Attach No. (Note 1) Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7 Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard RA, 1 per Min. 0.25-inch DensDeck Prime or SECUROCK GAF 2-PaEverGuard TPO / FastLayn TPO 5-84. 33 steel or min. 2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 4.0 ft2 Gypsum -Fiber Roof Board or OB500Adhesive -45.0* structural concrete Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-PaEverGuard TPO /FastLayn TPO 5-85. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 insulation followed by Min. 0.25-inch DensDeck LRF-M or] Adhesive -45.0* structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board OB500 Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-Part, EverGuard TPO /FastLayn TPO 5-86. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4.0 ft2 insulation followed by Min. 0.25-inch DensDeck LRF-M or Adhesive -45.0* structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board OB500 Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base GAF 2-Part, EverGuard TPO / FastLayn TPO 5-87. 33 steel or min. 2,500 psi Insulation Note 2 2.0 ft i insulation LRF-M or Adhesive -45.0* structural concrete OB500 Min. 22 ga., Type B, Grade Min inch EnergyGuard Polyiso per Additional optional layers, min. 0.5-inch base GAF 2-Part, EverGuard TPO /FastLayn TPO 5-88. 33 steel or min. 2,500 psi Insulation Note 2 4.0 ft2 insulation LRF-M or Adhesive -45.0* structural concrete OB500 Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part, EverGuard TPO / FastLayn TPO 5-89. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH Note 2 2.0 ft2 Board LRF-M or Adhesive -52.5 structural concrete OB500 Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard RA, 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part EverGuard TPO / FastLayn TPO 5-90. steel min. 2,500 psi EnergyGuard RN or EnergyGuard RH Note 2 1.6 ft2 Board or OB500 Adhesive -60.0 structural concrete Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part EverGuard TPO / FastLayn TPO 5-91. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA, Note 2 1.3 ft2 Board or OB500 Adhesive -60.0 structural concrete EnergyGuard RH or EnergyGuard RN Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / FastLayn TPO 5-92. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA or Note 2 1.3 ft2 Board LRF-M Adhesive -60.0 structural concrete EnergyGuard RN Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Min. inch EnergyGuard HD Polyiso EverGuard TPO /FastLayn TPO 5-93. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Polyiso Note 2 1.8 ft2 Insulation LRF-XF Adhesive -30.0 structural concrete Insulation Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso 1 per EverGuard TPO / FastLayn TPO 5-94. 33 steel or min. 2,500 psi Insulation Note 2 2.0 ft' Additional layers of base insulation LRF-XF Adhesive -45.0* structural concrete Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard RA or 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / FastLayn TPO 5-95. 33 steel or min. 2,500 psi EnergyGuard RH Note 2 2.0 ft2 Gypsum -Fiber Roof Board LRF-XF Adhesive -45.0* structural concrete NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 31 of 156 NNEMO I etc. TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer MDP Type Fasten Attach Type Attach No. (Note 1) Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,8) Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard RA or 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / FastLayn TPO 5-96. 33 steel or min. 2,500 psi EnergyGuard RH Note 2 4.0 ft2 Gypsum -Fiber Roof Board LRF-XF Adhesive -45.0* structural concrete Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO / FastLayn TPO 5-97. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 insulation followed by Min. 0.25-inch DensDeck LRF-XF Adhesive -45.0* structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO / FastLayn TPO 5-98. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4.0 ft2 insulation followed by Min. 0.25-inch DensDeck LRF-XF Adhesive -45.0* structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board Min. 22 ga., Type B, Grade Min inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO /FastLayn TPO 5-99. 33 steel or min. 2,500 psi Insulation Note 2 2.0 ft i insulation LRF-XF Adhesive -45.0* structural concrete Min. 22 ga., Type B, Grade Min inch EnergyGuard Polyiso per Additional optional layers, min. 0.5-inch base EverGuard TPO /FastLayn TPO 5-100. 33 steel or min. 2,500 psi Insulation Note 2 4..0 ft2 insulation LRF-XF Adhesive -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / FastLayn TPO 5-101. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH Note 2 2.0 ft2 Board LRF-XF Adhesive -52.5 structural concrete Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard RA or 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / FastLayn TPO 5-102. 33 steel or min. 2,500 psi EnergyGuard RH Note 2 1.6 ft2 Board LRF-XF Adhesive -60.0 structural concrete Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / FastLayn TPO 5-103. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA or Note 2 1.3 ft2 Board LRF-XF Adhesive -60.0 structural concrete EnergyGuard RH EverGuard TPO Fleece -Back Membrane in EverGuard WB 181 Bonding Adhesive: Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO Fleece -Back 5-104. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 insulation 0B500 Membrane / W6181 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO Fleece -Back 5-105. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4.0 ft� insulation 0B500 Membrane / W6181 -45.0* structural concrete Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard RA, 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back 5-106. 33 steel or min. 2,500 psi EnergyGuard RN, EnergyGuard RH Note 2 3.2 ft2 Gypsum -Fiber Roof Board OB500 Membrane / WB181 -37.5* structural concrete Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso 5-107. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra, Note 2 1 per Min. 0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO Fleece -Back -45.0* EnergyGuard RA, EnergyGuard RN, 2.0 ftz Gypsum -Fiber Roof Board Membrane / WB181 structural concrete EnergyGuard RH NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 32 of 156 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer MDP Type Fasten Attach Type Attach No. (Note 1) Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,8) Min. 22ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back 5-108. steelel min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4.0 ft2 Gypsum -Fiber Roof Board OB500 Membrane / WB181 -45.0* t stconcrete structural Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO Fleece -Back 5-109. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA, Note 2 1.3 ft2 Board OB500 Membrane/WB181 -60.0 structural concrete EnergyGuard RH or EnergyGuard RN Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO Fleece -Back 5-110. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 insulation LRF-M Membrane / WB181 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO Fleece -Back 5-111. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4.0 ft2 insulation LRF-M Membrane / W6181 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO Fleece -Back 5-112. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 insulation followed by Min. 0.25-inch DensDeck LRF-M Membrane / WB181 -45.0* structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO Fleece -Back 5-113. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4 .0 ft� insulation followed by Min. 0.25-inch DensDeck LRF-M Membrane/WB181 -45.0* structural concrete Prime or SECUROCK Gypsum -Fiber Roof Board Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO Fleece -Back 5-114. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA or Note 2 1.3 ft2 Board LRF-M Membrane / WB181 -60.0 structural concrete EnergyGuard RN Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO Fleece -Back 5-115. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 insulation LRFAF Membrane / WB181 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO Fleece -Back 5-116. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4.0 ft2 insulation LRFAF Membrane / WB181 -45.0* structural concrete Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO Fleece -Back 5-117. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA or Note 2 1.3 ft2 Board LRFAF Membrane / WB181 -60.0 structural concrete EnergyGuard RH Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO Fleece -Back 5-118. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft� insulation GAF 2-Part Membrane/WB181 -45.0* structural concrete Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Additional optional layers, min. 0.5-inch base EverGuard TPO Fleece -Back 5-119. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4.0 ft2 insulation GAF 2-Part Membrane/WB181 -45.0* structural concrete NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 33 of 156 NNEMO I etc. TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,8) Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO Fleece -Back S-120. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA, Note 2 1.3 ft2 Board GAF 2-Part Membrane / WB181 -60.0 structural concrete EnergyGuard RH or EnergyGuard RN EverGuard TPO Fleece -Back Membrane in LRF Adhesive M or LRF Adhesive O: Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per pft2er Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back S-121. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 Gypsum-Fiber Roof Board OB500 Membrane/ LRF-M or LRF-0, -45.0* structural concrete 12-inch o.c. Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back S-122. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 4.0 ft2 Gypsum -Fiber Roof Board OB500 Membrane / LRF-M or LRF-0, -45.0* structural concrete 12-inch o.c. Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back S-123. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 1 per 2 er followed by Min. 0.25-inch DensDeck Prime or OB500 Membrane / LRF-M or LRF-0, 4- -30.0* structural concrete EnergyGuard RN 3 SECUROCK Gypsum -Fiber Roof Board inch o.c. Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back S-124. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 1 per followed by Min. 0.25-inch DensDeck Prime or OB500 Membrane / LRF-M or LRF-0, 4- -45.0* structural concrete EnergyGuard RN 2 0 fti SECUROCK Gypsum -Fiber Roof Board inch o.c. Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back S-125. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 Z 9 erft2 followed by Min. 0.25-inch DensDeck Prime or OB500 Membrane / LRF-M or LRF-O, 4- -45.0* structural concrete EnergyGuard RN SECUROCK Gypsum -Fiber Roof Board inch o.c. Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 pe Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO Fleece -Back S-126. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA, Note 2 1 i .3 ft2 Board OB500 Membrane / LRF-M or LRF-O, 4- -60.0 structural concrete EnergyGuard RH or EnergyGuard RN inch o.c. Min. 22 ga., Type B, Grade Min 1.5-inch EnergyGuard Polyiso 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back S-127. 33 steel or min. 2,500 psi Insulation, EnergyGuard Ultra Note 2 2.0 ft2 Gypsum -Fiber Roof Board LRF-M Membrane / LRF-M or LRF-O, -45.0* structural concrete 12-inch o.c. Min. 22 ga., Type B, Grade Min 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back S-128. 33 steel or min. 2,500 psi Note 2 LRF-M Membrane / LRF-M or LRF-0, -45.0* structural concrete Insulation, EnergyGuard Ultra 4.0 ft2 Gypsum -Fiber Roof Board 12-inch o.c. Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back 5-129. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 1 per followed by Min. 0.25-inch DensDeck Prime or LRF-M Membrane / LRF-M or LRF-0, 4- -30.0* structural concrete EnergyGuard RN 3.2 ft' SECUROCK Gypsum -Fiber Roof Board inch o.c. Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back S-130. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 1 per O er followed by Min. 0.25-inch DensDeck Prime or LRF-M Membrane / LRF-M or LRF-0, 4- -45.0* structural concrete EnergyGuard RN 2 SECUROCK Gypsum -Fiber Roof Board inch o.c. Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back S-131. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 1 per 2.9 ft2SECUROCK followed by Min. 0.25-inch DensDeck Prime or LRF-M Membrane / LRF-M or LRF-O, 4- -45.0* structural concrete EnergyGuard RN Gypsum -Fiber Roof Board inch o.c. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 34 of 156 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer MDP Type Fasten Attach Type Attach No. (Note 1) Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,8) Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO Fleece -Back 5-132. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA or Note 2 LRF-M Membrane / LRF-M or LRF-0, 4- -60.0 structural concrete EnergyGuard RN 1.3 ft� Board inch o.c. Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso per Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back 5-133. 33 steel or min. 2,500 psi Insulation or EnergyGuard RH Note Note 2 3.2 ft i followed by Min. 0.25-inch DensDeck Prime or LRF-XF Membrane / LRF-M or LRF-O, 4- -30.0* structural concrete SECUROCK Gypsum -Fiber Roof Board inch o.c. Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso 1 per erft2 Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back 5-134. 33 steel or min. 2,500 psi Insulation EnergyGuard RH Note 2 2 0 followed by Min. 0.25-inch DensDeck Prime or LRF-XF Membrane / LRF-M or LRF-O, 4- -45.0* structural concrete SECUROCK Gypsum -Fiber Roof Board inch o.c. Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back 5-135. 33 steel or min. 2,500 psi Insulation or EnergyGuard RH Note 2 2ft� followed by Min. 0.25-inch DensDeck Prime or _RF-XF Membrane / LRF-M or LRF-O, 4- -45.0* structural concrete SECUROCK Gypsum -Fiber Roof Board inch o.c. Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO Fleece -Back 5-136. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA or Note 2 1 ft� Board LRF-XF Membrane / LRF-M or LRF-0, 4- -60.0 structural concrete EnergyGuard RH .3 inch o.c. Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back 5-137. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 1 per followed by Min. 0.25-inch DensDeck Prime or GAF 2-Part Membrane / LRF-M or LRF-0, 4- -30.0* structural concrete EnergyGuard RN 3.2 ft� SECUROCK Gypsum -Fiber Roof Board inch o.c. Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back 5-138. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 1 per perft2 followed by Min. 0.25-inch DensDeck Prime or GAF 2-Part Membrane / LRF-M or LRF-O, 4- -45.0* structural concrete EnergyGuard RN 2 SECUROCK Gypsum -Fiber Roof Board inch o.c. Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back 5-139. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 1 er 2 9 fti followed by Min. 0.25-inch DensDeck Prime or GAF 2-Part Membrane / LRF-M or LRF-O, 4- -45.0* structural concrete EnergyGuard RN SECUROCK Gypsum -Fiber Roof Board inch o.c. Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO Fleece -Back 5-140. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA, Note 2 1.3 ft: Board GAF 2-Part Membrane / LRF-M or LRF-O, 4- -60.0 structural concrete EnergyGuard RH or EnergyGuard RN inch o.c. EverGuard TPO Fleece -Back Membrane in Spatter Applications: Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back Membrane / GAF 2-Part 5-141. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 3.2 ft i followed by Min. 0.25-inch DensDeck Prime or OB500 (spatter), LRF-XF (spatter) or -30.0* structural concrete EnergyGuard RN SECUROCK Gypsum -Fiber Roof Board OB500 (spatter) Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back 1 per Membrane / GAF 2-Part 5-142. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 2.0 ft2 followed by Min. 0.25-inch DensDeck Prime or OB500 (spatter), LRF-XF (spatter) or -45.0* structural concrete EnergyGuard RN SECUROCK Gypsum -Fiber Roof Board OB500 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 35 of 156 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, Base Insulation Layer BONDED TOP INSULATION, BONDED ROOF COVER Top Insulation Layer MDP Type Fasten Attach Type Attach No. (Note 1) Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,8) Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back Membrane / GAF 2-Part 5-143. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 2.9 ft2 followed by Min. 0.25-inch DensDeck Prime or OB500 (spatter), LRF-XF (spatter) or -45.0* structural concrete EnergyGuard RN SECUROCK Gypsum -Fiber Roof Board OB500 (spatter) Min. 22 ga., Type B, Grade EverGuard TPO Fleece -Back Min 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Membrane / GAF 2-Part 5-144. steelorl min. 2,500 psi Insulation, EnergyGuard RH Note 2 2.0 ft2 Board OB500 (spatter), LRF-XF (spatter) or -52.5 t concrete structural OB500 (spatter) Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per EverGuard TPO Fleece -Back 5-145. 33 steel or min. 2,500 psi Insulation Note 2 1 8 ft2 Min. 1.5-inch x max. 4x4 ft base insulation OB500 Membrane / OB500 (spatter) -60.0 structural concrete Optional layers of min. 1.5-inch x max. 44 ft Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per base insulation followed by min. 0.25-inch x EverGuard TPO Fleece -Back 5-146. 33 steel or min. 2,500 psi Insulation Note 2 1 .8 ft� max. 4x4 ft DensDeck Prime or SECUROCK OB500 Membrane / OB500 (spatter) -60.0 structural concrete Gypsum -Fiber Roof Board or min. 0.5-inch x max. 44 ft EnergyGuard HD Polyiso Insulation Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso EverGuard TPO Fleece -Back 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Membrane / GAF Part 5-147. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA, Note 2 13 ft2 . Board OB500 spatter) or (spatter), LRF-XF (spatter) -60.0 structural concrete EnergyGuard RH or EnergyGuard RN OB500 (spatter) Min. 22 ga., Type B, Grade Min. EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard Fleece -Back 5-148. 33 steel or min. 2,500 psi tinch Insulation on Note 2 1 .8 ft2 Board or or min. 0.5-inch x max. 4x4 ft OB500 Membrane / / O OB500 (spatter) -67.5 structural concrete EnergyGuard HD Polyiso Insulation Min. 22 ga., Type B, Grade Min. 3-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof 013500, 4- EverGuard TPO Fleece -Back 5-149. 80 steel or min. 2,500 psi Insulation or EnergyGuard Ultra Note 2 1.0 ft2 Board inch o.c. Membrane / OB500 (spatter) -120.0 structural concrete Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back 1 per Membrane / GAF 2-Part 5-150. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 3.2 ft2 followed by Min. 0.25-inch DensDeck Prime or LRF-M (spatter), LRF(spatter) or -30.0* structural concrete EnergyGuard RN SECUROCK Gypsum -Fiber Roof Board OB500 (spatter) Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back 1 per Membrane / GAF 2-Part 5-151. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 2.0 ft2 followed by Min. 0.25-inch DensDeck Prime or LRF-M (spatter), LRF-XF (spatter) or -45.0* structural concrete EnergyGuard RN SECUROCK Gypsum -Fiber Roof Board OB500 (spatter) Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard G Fleece -Back Membrane / / GAF 5-152. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 .per 29 ft2 followed by Min. 0.25-inch DensDeck Prime or LRF-M spPart (spatter), LRF(spatter) or -45.0* structural concrete EnergyGuard RN SECUROCK Gypsum -Fiber Roof Board OB500 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMo ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 36 of 156 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, Base Insulation Layer BONDED TOP INSULATION, BONDED ROOF COVER Top Insulation Layer MDP Type Fasten Attach Type Attach No. (Note 1) Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,8) Min. 22 ga., Type B, Grade EverGuard TPO Fleece -Back Min 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Membrane / GAF 2-Part 5-153. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH Note 2 2.0 ft2 Board LRF-M (spatter), LRF-XF (spatter) or -52.5 structural concrete OB500 (spatter) Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso EverGuard TPO Fleece -Back 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Membrane / GAF 2-Part 5-154. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA or Note 2 1.3 ft2 Board LRF-M (spatter), LRF-XF (spatter) or -60.0 structural concrete EnergyGuard RN OB500 (spatter) Min. 22 ga., Type B, Grade Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back Min. 2-inch EnergyGuard Polyiso 1 per Membrane / GAF 2-Part 5-155. 33 steel or min. 2,500 psi Insulation or EnergyGuard RH Note 2 3.2 ft� followed by Min. 0.25-inch DensDeck Prime or LRF-XF (spatter), LRF-XF (spatter) or -30.0* structural concrete SECUROCK Gypsum -Fiber Roof Board OBS00 (spatter) Min. 22 ga., Type B, Grade Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back Min. 1.5-inch EnergyGuard Polyiso 1 per Membrane / GAF 2-Part 5-156. 33 steel or min. 2,500 psi Insulation or EnergyGuard RH Note 2 2.0 ft2 followed by Min. 0.25-inch DensDeck Prime or LRF-XF (spatter), LRF-XF (spatter) or -45.0* structural concrete SECUROCK Gypsum -Fiber Roof Board OB500 (spatter) Min. 22 ga., Type B, Grade Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back Min. 2-inch EnergyGuard Polyiso 1 per Membrane / GAF 2-Part 5-157. 33 steel or min. 2,500 psi Insulation or EnergyGuard RH Note 2 2.9 ft� followed by Min. 0.25-inch DensDeck Prime or LRF-XF (spatter), LRF-XF (spatter) or -45.0* structural concrete SECUROCK Gypsum -Fiber Roof Board OB500 (spatter) Min. 22 ga., Type B, Grade EverGuard TPO Fleece -Back 5-158. 33 steel or min. 2,500 psi Min 2-inch EnergyGuard Polyiso Note 2 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof LRF-XF Membrane / GAF 2-Part -52.5 Insulation or EnergyGuard RH 2.0 ft2 Board (spatter), LRF-XF (spatter) or structural concrete 0B500 (spatter) Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso EverGuard TPO Fleece -Back 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Membrane / GAF 2-Part 5-159. steel min. 2,500 psi Insulation, EnergyGuard RA or Note 2 1.3 ft2 Board LRF-XF (spatter), LRF-XF (spatter) or -60.0 structural stconcrete EnergyGuard RH OB500 (spatter) Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard Fleece -Back Fleece-Back / G Membrane / G 5-160. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH Note 2 .per 3, 2 ft� followed by Min. 0.25-inch DensDeck Prime or GAF 2-Part (spatter), LRF (spatter) or (sp -30.0* structural concrete EnergyGuard RN SECUROCK Gypsum -Fiber Roof Board OBS00 (spatter) Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back 1 per Membrane / GAF 2-Part 5-161. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 2.0 ft' followed by Min. 0.25-inch DensDeck Prime or GAF 2-Part (spatter), LRF-XF (spatter) or -45.0* structural concrete EnergyGuard RN SECUROCK Gypsum -Fiber Roof Board OB500 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 37 of 156 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, Base Insulation Layer BONDED TOP INSULATION, BONDED ROOF COVER Top Insulation Layer MDP Type Fasten Attach Type Attach No. (Note 1) Roof Cover (Note 15) (Psf) (Note 11) (Notes 6,7,8) Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso 1 per Optional layers of min. 0.5-inch base insulation EverGuard TPO Fleece -Back Membrane / GAF 2-Part 5-162. 33 steel or min. 2,500 psi Insulation, EnergyGuard RH, Note 2 2.9 ft2 followed by Min. 0.25-inch DensDeck Prime or GAF 2-Part (spatter), LRF-XF (spatter) or -45.0* structural concrete EnergyGuard RN SECUROCK Gypsum -Fiber Roof Board OB500 (spatter) Min. 22 ga., Type B, Grade EverGuard TPO Fleece -Back Min 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Membrane / GAF 2-Part 5-163. steelorl min. 2,500 psi Insulation, EnergyGuard RH Note 2 2.0 ft2 Board GAF 2-Part (spatter), LRF-XF (spatter) or -52.5 t concrete structural OB500 (spatter) Min. 22 ga., Type B, Grade Min. 2-inch EnergyGuard Polyiso EverGuard TP0 Fleece -Back 1 per Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Membrane /GAF 2-Part 5-164. 33 steel or min. 2,500 psi Insulation, EnergyGuard RA, Note 2 1.3 ft� Board GAF 2-Part (spatter), LRF-XF (spatter) or -60.0 structural concrete EnergyGuard RH or EnergyGuard RN OB500 (spatter) TABLE 2c: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED BASE AND CAP PLY Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) Deck System No. (Note 1) Type Fasten Attach Type Attach Base Ply Cap Ply F�7 (Note 11) (Notes 6,7,8) Asphalt -Applied Base Ply: Optional layers of base GAFGLAS #75 Base Sheet, Tri- Min. 22 ga., Type Min 1.5-inch EnergyGuard insulation followed by Ply #75 Base Sheet, GAFGLAS 5-165. B, Grade 33 steel Polyiso Insulation, EnergyGuard Note 2 1 per Min. 0.25-inch DensDeck, Hot asphalt #80 Ultima Base Sheet, EverGuard TPO Fleece -Back -45.0* or min. 2,500 psi Ultra 2.0 ft2 DensDeck Prime or Ruberoid 20 Smooth, Ruberoid Membrane / hot asphalt structural concrete SECUROCK Gypsum -Fiber Mop Smooth or Ruberoid Mop Roof Board Smooth 1.5 / hot asphalt Optional layers of base GAFGLAS #75 Base Sheet, Tri- Min. 22 ga., Type insulation followed by Ply #75 Base Sheet, GAFGLAS 5-166. B, Grade 33 steel Min 1.5-inch EnergyGuard RA, Note 2 1 per Min. 0.25-inch DensDeck, Hot asphalt #80 Ultima Base Sheet, EverGuard TPO Fleece -Back -45.0* or min. 2,500 psi EnergyGuard RN 4.0 ft2DensDeck Prime or Ruberoid 20 Smooth, Ruberoid Membrane / hot asphalt structural concrete SECUROCK Gypsum -Fiber Mop Smooth or Ruberoid Mop Roof Board Smooth 1.5 / hot asphalt Optional layers of min. GAFGLAS #75 Base Sheet, Tri- Min. 22 ga., Type 0.5-inch base insulation Ply #75 Base Sheet, GAFGLAS 5-167. B, Grade 33 steel Min 2-inch EnergyGuard Polyiso Note 2 1 per followed by Min. 0.25-inch Hot asphalt #80 Ultima Base Sheet, EverGuard TPO Fleece -Back -45.0* or min. 2,500 psi Insulation, EnergyGuard Ultra 4.0 ft2 DensDeck, DensDeck Ruberoid 20 Smooth, Ruberoid Membrane / hot asphalt structural concrete Prime or SECUROCK Mop Smooth or Ruberoid Mop Gypsum -Fiber Roof Board Smooth 1.5 / hot asphalt NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 38 of 156 NNEMO I etc. TABLE 2c: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED Base Insulation Layer BASE BONDED TOP INSULATION, BONDED B Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Type Fasten Attach Type Attach Base Ply Cap Ply MDP (psf) (Note 11) (Notes 6,7,8) Optional layers of min. GAFGLAS #75 Base Sheet, Tri- Min. 22 ga., Type 1.5-inch base insulation Ply #75 Base Sheet, GAFGLAS 5-168. B, Grade 33 steel Min 2-inch EnergyGuard RA Note 2 1 per followed by Min. 0.25-inch Hot asphalt #80 Ultima Base Sheet, EverGuard TPO Fleece -Back -45.0* or min. 2,500 psi 5.3 ft2 DensDeck, DensDeck Ruberoid 20 Smooth, Ruberoid Membrane / hot asphalt structural concrete Prime or SECUROCK Mop Smooth or Ruberoid Mop Gypsum -Fiber Roof Board Smooth 1.5 / hot asphalt Optional layers of base GAFGLAS #75 Base Sheet, Tri- Min. 22 ga., Type insulation followed by Ply #75 Base Sheet, GAFGLAS B, Grade 33 steel Min 1.5-inch EnergyGuard RA or 1 per Min. 0.25-inch DensDeck, GAF 2-Part #80 Ultima Base Sheet, EverGuard TPO Fleece -Back 5-169. or min. 2,500 psi EnergyGuard RN Note 2 2.0 W DensDeck Prime or or OB500 Ruberoid 20 Smooth, Ruberoid Membrane / hot asphalt -45.0* structural concrete SECUROCK Gypsum -Fiber Mop Smooth or Ruberoid Mop Roof Board Smooth 1.5 / hot asphalt Optional layers of min. GAFGLAS #75 Base Sheet, Tri- Min. 22 ga., Type 1.5-inch base insulation Ply #75 Base Sheet, GAFGLAS 5-170. B, Grade 33 steel Min 2-inch EnergyGuard RA or Note 2 1 per followed by Min. 0.25-inch GAF 2-Part #80 Ultima Base Sheet, EverGuard TPO Fleece -Back -45.0* or min. 2,500 psi EnergyGuard RN 4.0 ft2 DensDeck, DensDeck or OB500 Ruberoid 20 Smooth, Ruberoid Membrane / hot asphalt structural concrete Prime or SECUROCK Mop Smooth or Ruberoid Mop Gypsum -Fiber Roof Board Smooth 1.5 / hot asphalt Min. 1.5-inch EnergyGuard EverGuard TPO Fleece -Back Min. 22 ga., Type Polyiso Insulation, EnergyGuard Membrane / hot asphalt, GAF 2- 5-171. B, Grade 33 steel, RA, EnergyGuard RH, Note 2 1 per Min. 0.25-inch SECUROCK GAF 2-Part Ruberoid 20 Smooth /hot Part (spatter), LRF-XF (spatter) -60.0 or min. 2,500 psi EnergyGuard RM or 1.3 ft2 Gypsum -Fiber Roof Board or OB500 asphalt or OB500 (spatter) or LRF-O, 12- structural concrete EnergyGuard RN inch o.c. Optional layers of base GAFGLAS #75 Base Sheet, Tri- Min. 22 ga., Type insulation followed by Ply #75 Base Sheet, GAFGLAS 5-172. B, Grade 33 steel Min 1.5-inch EnergyGuard RA Note 2 1 per Min. 0.25-inch DensDeck LRF-XF #80 Ultima Base Sheet, EverGuard TPO Fleece -Back -45.0* or min. 2,500 psi 2.0 ft2Prime Ruberoid 20 Smooth, Ruberoid Membrane / hot asphalt structural concrete or SECUROCK Mop Smooth or Ruberoid Mop Gypsum -Fiber Roof Board Smooth 1.5 /hot asphalt Optional layers of min. GAFGLAS #75 Base Sheet, Tri- Min. 22 ga., Type 1.5-inch base insulation Ply #75 Base Sheet, GAFGLAS 5-173. B, Grade 33 steel Min 2-inch EnergyGuard RA Note 2 1 per followed by Min. 0.25-inch LRF-XF #80 Ultima Base Sheet, EverGuard TPO Fleece -Back -45.0* or min. 2,500 psi 4.0 ft2 DensDeck Prime or Ruberoid 20 Smooth, Ruberoid Membrane / hot asphalt structural concrete SECUROCK Gypsum -Fiber Mop Smooth or Ruberoid Mop Roof Board Smooth 1.5 / hot asphalt NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 39 of 156 NNEMO I etc. TABLE 2c: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER Deck SYSTEM TYPE B-1: MECHANICALLY ATTACHED Base Insulation Layer BASE BONDED TOP INSULATION, BONDED B Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Type Fasten Attach Type Attach Base Ply Cap Ply MDP (psf) (Note 11) (Notes 6,7,8) EverGuard TPO Fleece -Back Min. 22 ga., Type Min. 1.5-inch EnergyGuard Membrane / hot asphalt, GAF 2- 5-174. B, Grade 33 steel, Polyiso Insulation, EnergyGuard Note 2 1 per Min. 0.25-inch SECUROCK LRF-XF Ruberoid 20 Smooth / hot Part (spatter), LRF-XF (spatter) -60.0 or min. 2,500 psi RA or EnergyGuard RH 1.3 ft2 Gypsum -Fiber Roof Board asphalt or OB500 (spatter) or LRF-O, 12- structural concrete inch o.c. Torch -Applied Base Ply: Min. 1.5-inch EnergyGuard EverGuard TPO Fleece -Back Min. 22 ga., Type B, Polyiso Insulation, EnergyGuard Membrane/hot asphalt, GAF 2- 5-175. Grade 33 steel, or RA, EnergyGuard RH, Note 2 1 per Min. 0.25-inch SECUROCK GAF 2-Part Ruberoid HW 25 Smooth / Part (spatter), LRF-XF (spatter) -60.0 min. 2,500 psi EnergyGuard RM or 1.3 ft2 Gypsum -Fiber Roof Board or OB500 torch -applied or OB500 (spatter) or LRF-O, 12- structural concrete EnergyGuard RN inch o.c. Min. 22 ga., Type B, EverGuard TPO Fleece -Back Grade 33 steel, or Min. 1.5-inch EnergyGuard 1 per Min. 0.25-inch SECUROCK Ruberoid HW 25 Smooth / Membrane / hot asphalt, GAF 2- 5-176. min. 2,500 psi Polyiso Insulation, EnergyGuard Note 2 1.3 ft2 Gypsum -Fiber Roof Board LRF-XF torch -applied Part (spatter), LRF-XF (spatter) -60.0 RA or EnergyGuard RH or OB500 (spatter) or LRF-O, 12- structuralconcrete inch o.c. Self -Adhering Base Ply: Min. 1.5-inch EnergyGuard EverGuard TPO Fleece -Back Min. 22 ga., Type B, Polyiso Insulation, EnergyGuard Membrane / hot asphalt, GAF 2- 5-177. a 33 Grade 33 steel, or RA, EnergyGuard RH, Note 2 1 per Min. 0.25-inch SECUROCK GAF 2-Part Liberty SBS Self -Adhering Cap Part (spatter), LRF-XF (spatter) -60.0 min. psi EnergyGuard RM or 1.3 ft2 Gypsum -Fiber Roof Board or OB500 Sheet / self -adhered or OB500 (spatter) or LRF-0, 12- structural concrete EnergyGuard RN inch o.c. EverGuard TPO Fleece -Back Min. 22 ga., Type B, Min. 1.5-inch EnergyGuard Membrane / hot asphalt, GAF 2- 5-178. Grade 33 steel, or Polyiso Insulation, EnergyGuard Note 2 1 per Min. 0.25-inch SECUROCK LRF-XF Liberty SBS Self -Adhering Cap Part (spatter), LRF-XF (spatter) -60.0 min. psi RA or EnergyGuard RH 1.3 ft2 Gypsum -Fiber Roof Board Sheet / self -adhered or OBS00 (spatter) or LRF-0, 12- structural uralconcrete inch o.c. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 40 of 156 *NEMO I etc. TABLE 2D: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) BONDEDSYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, TEMP ROOF,BONDED TOP INSULATION, BONDED ROOF COVER Thermal Barrier Insulation Layer(s) System Deck MDP Temp Roof Attach Roof Cover (Note 15) No. (Note 1) Type Fasten (Note 11) Attach Type (Psf) (Notes 6,7,8) EverGuard Freedom TPO: Min. 22 ga., Note 2 (Drill-Tec 3 in. Grade 33 Min. 0.5-inch Ribbed Galvalume Min. 1.5-inch EnergyGuard RH followed by Min. 5-179. steel or min. SECUROCK Plate (Flat) may be 1 per Liberty SBS Self -Adhering 0.5-inch EnergyGuard RH HD Polyiso Insulation, OB500 EverGuard Freedom TPO / -45.0* 2,500 psi Gypsum -Fiber used) (no recessed 2.7 ft' Cap Sheet, self -adhering EnergyGuard HD Polyiso Insulation, EnergyGuard self adhered structural Roof Board plate) HD Plus Polyiso Insulation concrete 0.5-inch Primer: GAF SA Primer or One or more layers, base layer min. 1-inch thick, Min. 22 ga., DensDeck Note 2 (Drill-Tec 3 in. Matrix 307 Premium optional subsequent layer(s) min. 1.5-inch thick Type B, Prime or Ribbed Galvalume 1 per Asphalt Primer EnergyGuard RN LRF-M or EverGuard Freedom TPO / 5-180. Grade 33 SECUROCK Plate (Flat) may be 4.0 ft2 Vapor Retarder: GAF SA (Optional) Min. 0.25-inch DensDeck Prime or OB500 self adhered -45.0* steel Gypsum Fiber used) (no recessed Vapor Retarder, self- SECUROCK Gypsum -Fiber Roof Board or min. 0.5- Roof Board plate) adhering inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation One or more layers, base layer min. 1-inch thick, 0.5-inch Primer: GAF SA Primer or optional subsequent layer(s) min. 1.5-inch thick Min. 22 ga., DensDeck Note 2 (Drill-Tec 3 in. Matrix 307 Premium EnergyGuard Polyiso Insulation, EnergyGuard GAF 2-Part, Type B, Prime or Ribbed Galvalume 1 per Asphalt Primer Ultra Polyiso Insulation LRF-M, LRF- EverGuard Freedom TPO / 5-181. Grade 33 SECUROCK Plate (Flat) may be 4.0 ft2 Vapor Retarder: GAF SA (Optional) Min. 0.25-inch DensDeck Prime or XF or self adhered -45.0* steel Gypsum Fiber used) (no recessed Vapor Retarder, self- SECUROCK Gypsum -Fiber Roof Board or min. 0.5- OB500 Roof Board plate) adhering inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation Min. 22 ga., 0.5-inch DensDeck Note 2 (Drill-Tec 3 in. Primer: GAF SA Primer One or more layers, base layer min. 1-inch thick, GAF 2-Part, Type B, Prime or Ribbed Galvalume 1 per Vapor Retarder: GAF SA optional subsequent layer(s) min. 1.5-inch thick LRF-M, LRF- EverGuard Freedom TPO / 5-182. Grade 33 SECUROCK Plate (Flat) may be 2.0 ft� Vapor Retarder, self- EnergyGuard Polyiso Insulation, EnergyGuard XF or self adhered -60.0 steel Gypsum Fiber used) (no recessed adhering Ultra Polyiso Insulation followed by Min. 0.25- OB500 Roof Board plate) inch SECUROCK Gypsum -Fiber Roof Board EverGuard TPO: Min. 22 ga., Note 2 (Drill-Tec 3 in. Grade 33 Min. 0.5-inch Ribbed Galvalume Min. 1.5-inch EnergyGuard RH followed by Min. EverGuard / 5-183. steel or min. SECUROCK Plate (Flat) may be 1 per Liberty SBS Self -Adhering 0.5-inch EnergyGuard RH HD Polyiso Insulation, OB500 re, O 3- TPO 6-Square, TPO 3- -45.0* 2,500 psi Gypsum -Fiber used) (no recessed 2 7 ft� Cap Sheet, self -adhering EnergyGuard HD Polyiso Insulation, EnergyGuard Square, W6181 structural Roof Board plate) HD Plus Polyiso Insulation concrete NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 41 of 156 *NEMO I etc. TABLE 21): STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) TYPE B-2: MECHANICALLY ATTACHED BONDEDSYSTEM THERMAL BARRIER, TEMP ROOF,BONDED TOP INSULATION, BONDED ROOF COVER System Deck Thermal Barrier Insulation Layer(s) MDP Type Fasten (Note 11) Attach Type Attach No. (Note 1) Temp Roof Roof Cover (Note 15) (Psf) (Notes 6,7,8) Min. 22 ga., Note 2 (Drill-Tec 3 in. Grade Ribbed Ribbed Galvalume Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO/#1121, 5-184. or steel or min. SECUROCK SECURn. OCK Plate (Flat) may be 1 per Liberty SBS Self -Adhering EnergyGuard Ultra, EnergyGuard RA, OB500 TPO 6-Square, TPO 3- -45.0* 2,500 psi Gypsum -Fiber used) (no recessed 2.7 ft2 Cap Sheet, self -adhering EnergyGuard RN Square, WB181 structural Roof Board plate) concrete Min. 22 ga., Note 2 (Drill-Tec 3 in. Min. 1.5-inch EnergyGuard Polyiso Insulation, Grade 33 Min. 0.5-inch Ribbed Galvalume EnergyGuard Ultra, EnergyGuard RA, EverGuard TPO / #1121, 5-185. steel or min. SECUROCK Plate (Flat) may be 1 per Liberty SBS Self -Adhering EnergyGuard RN followed by Min. 0.25-inch OB500 TPO 6-Square, TPO 3- -45.0* 2,500 psi Gypsum -Fiber used) (no recessed 2.7 ft i Cap Sheet, self -adhering DensDeck Prime or SECUROCK Gypsum -Fiber Square, WB181 structural Roof Board plate) Roof Board concrete Min. 22 ga., Note 2 (Drill-Tec 3 in. 3 Grade 33 Ribbed Galvalume Two plies GAFGLAS Ply 4, EverGuard TPO / #1121, 5-186. steel or min. Min. 0.625-inch Plate (Flat) may be 1 per GAFGLAS Ply 4 M, Min. 1.5-inch EnergyGuard RA hot asphalt TPO 6-Square, TPO 3- -45.0* 2,500 psi DensDeck used) (no recessed 4.0 ft i applied in hot asphalt or OB500 Square structural plate) concrete Min. 22 ga., Note 2 (Drill-Tec 3 in. Grade 33 Min. 0.5-inch Ribbed Galvalume Min.1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / #1121, 5-187. steel or min. SECUROCK Plate (Flat) may be 1 per Liberty SBS Self -Adhering EnergyGuard Ultra, EnergyGuard RA, OB500 TPO 6-Square, TPO 3- -45.0* 2,500 psi Gypsum -Fiber used) (no recessed 2.7 ft2 Cap Sheet, self -adhering EnergyGuard RN, EnergyGuard RH Square, WB181 structural Roof Board plate) concrete Min. 22 ga., Note 2 (Drill-Tec3 in. Min. 1.5-inch EnergyGuard Polyiso Insulation, Grade 33 3 Min. inch Ribbed Galvalume EnergyGuard Ultra, EnergyGuard RA, EverGuard TPO / #1121, 5-188. steel or min. SECUROCK Plate (Flat) may be 1 per Liberty SBS Self -Adhering EnergyGuard RN, EnergyGuard RH followed by OB500 TPO 6-Square, TPO 3- -45.0* 2,500 psi used) (no recessed 2.7 ft2 Cap Sheet, self -adhering min. 0.25-inch DensDeck Prime or SECUROCK Square, WB181 structural Roof BoarGypsum-Fd Roof Board plate) Gypsum -Fiber Roof Board concrete One or more layers, base layer min. 1-inch thick, 0.5-inch Note 2 (Drill-Tec 3 in. Primer: GAF SA Primer or optional subsequent layer(s) min. 1.5-inch thick Min. 22 ga., DensDeck Ribbed Galvalume Matrix 307 Premium EnergyGuard RN EverGuard TPO / #1121, 5-189. Type B, Prime or Plate (Flat) may be 1 per Asphalt Primer (Optional) Min. 0.25-inch DensDeck Prime or LRF-M or TPO 6-Square, TPO 3- -45.0* Grade 33 SECUROCK used) (no recessed 4.0ft2 Vapor Retarder: GAF SA ROCK Gypsum-FiberRoof Board or min. 0.5- OB500 Square, W6181 steel Gypsum Fiber plate) Vapor Retarder, self- nchSEC i nch EnergyGuard HD Polyiso Insulation or Roof Board adhering EnergyGuard HD Plus Polyiso Insulation NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 42 of 156 *NEMO I etc. TABLE 21): STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF,BONDED TOP INSULATION, BONDED ROOF System Deck Thermal Barrier Insulation Layer(s) MDP Type Fasten (Note 11) Attach Type Attach No. (Note 1) Temp Roof Roof Cover (Note 15) (Psf) (Notes 6,7,8) One or more layers, base layer min. 1-inch thick, 0.5-inch Note 2 (Drill-Tec 3 in. Primer: GAF SA Primer or optional subsequent layer(s) min. 1.5-inch thick Min. 22 ga., DensDeck Ribbed Galvalume Matrix 307 Premium EnergyGuard Polyiso Insulation, EnergyGuard GAF 2-Part, EverGuard TPO / #1121, 5-190. Type B, Prime or Plate (Flat) may 1 per Asphalt Primer Ultra Polyiso Insulation LRF-M, LRF- TPO 6-Square, TPO 3- -45.0* Grade 33 SECUROCK 4.0 ft2 Vapor Retarder: GAF SA (Optional) Min. 0.25-inch DensDeck Prime or XF or steel Gypsum Fiber used) (no recessed Vapor Retarder, self- SECUROCK Gypsum -Fiber Roof Board or min. 0.5- OB500 Square, W6181 Roof Board plate) adhering inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation 0.5-inch Note 2 (Drill-Tec 3 in. One or more layers, base layer min. 1-inch thick, Min. 22 ga., DensDeck Ribbed Galvalume Primer: GAF SA Primer optional subsequent layer(s) min. 1.5-inch thick GAF 2-Part, 5-191. Type B, Prime or Plate (Flat) maybe 1 per Vapor Retarder: GAF SA EnergyGuard Polyiso Insulation, EnergyGuard LRF-M, LRF- EverGuard TPO / TPO 6- -52.5 Grade 33 SECUROCK used) (no recessed 2.0 ft' Vapor Retarder, self- Ultra Polyiso Insulation followed by Min. 0.25- XF or Square steel Gypsum Fiber plate) adhering inch DensDeck Prime OB500 Roof Board Min. 2ga., DensDeck 0ensDh Note 2 (Drill-Tec 3 in. Primer: GAF SA Primer One or more layers, base layer min. 1-inch thick, GAF 2-Part, Type B, Prime or Ribbed Galvalume 1 per Vapor Retarder: GAF SA optional subsequent layer(s) min. 1.5-inch thick LRF-M, LRF- EverGuard TPO / #1121, 5-192. Grade 33 SECUROCK Plate (Flat) may be 2.0 ft2 Vapor Retarder, self- EnergyGuard Polyiso Insulation, EnergyGuard XF or TPO 3-Square, WB181 -67.5 steel Gypsum Fiber used) (no recessed adhering Ultra Polyiso Insulation followed by Min. 0.25- OB500 Roof Board plate) inch DensDeck Prime 0.5-inch Note 2 (Drill-Tec 3 in. One or more layers, base layer min. 1-inch thick, Min. 22 ga., DensDeck Ribbed Galvalume Primer: GAF SA Primer optional subsequent layer(s) min. 1.5-inch thick GAF 2-Part, EverGuard, / 121, 5-193. Type B, Prime or Plate (Flat) may be 1 per Vapor Retarder: GAF SA EnergyGuard Polyiso Insulation, EnergyGuard LRF-M, LRF- TPO 6-Square, TPOO 3- 3- -67.5 Grade 33 SECUROCK used) (no recessed 2.0 ft2 Vapor Retarder, self- Ultra Polyiso Insulation followed by Min. 0.25- XF or Square, W6181 steel Gypsum Fiber plate) adhering inch DensDeck Prime or SECUROCK Gypsum- OB500 Roof Board Fiber Roof Board EverGuard TPO / EverGuard TPO Quick Spray Adhesive or EverGuard TPO Quick Spray LV 50: Min. 22 ga., Note 2 (Drill-Tec 3 in. Grade 33 Min. 0.5-inch Ribbed Galvalume Insulation: Min. 1.5-inch EnergyGuard Polyiso 5-194. steel or min. SECUROCK Plate (Flat) maybe 1 per Liberty SBS Self -Adhering Insulation or EnergyGuard RA OB500 EverGuard TPO / TPO QSA -45.0* 2,500 psi Gypsum -Fiber used) (no recessed 2.7 ft' Cap Sheet, self -adhering Coverboard: (Optional) Min. 0.25-inch DensDeck or TPO QSA LVSO structural Roof Board plate) Prime or SECUROCK Gypsum -Fiber Roof Board concrete 0.5-inch Note 2 (Drill-Tec 3 in. Primer: GAF SA Primer or Min. 22 ga., DensDeck Matrix 307 Premium Insulation: Min. 1.5-inch EnergyGuard Polyiso GAF 2-Part, Type B, Prime or Ribbed Galvalume 1 per Asphalt Primer Insulation or EnergyGuard RA LRF-M, LRF- EverGuard TPO / TPO QSA 5-195. Grade 33 SECUROCK Plate (Flat) may be 4.0 ft' Vapor Retarder: GAF SA Coverboard: (Optional) Min. 0.25-inch DensDeck XF or or TPO QSA LVSO -45.0* used) (no recessed steel Gypsum Fiber plate) Vapor Retarder, self- Prime or SECUROCK Gypsum -Fiber Roof Board OB500 Roof Board adhering NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #31455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMD ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 43 of 156 *NEMO I etc. TABLE 2D: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF,BONDED TOP INSULATION, BONDED ROOF System Deck Thermal Barrier Insulation Layer(s) MDP Type Fasten (Note 11) Attach Type Attach No. (Note 1) Temp Roof Roof Cover (Note 15) (Psf) (Notes 6,7,8) 0.5-inch Note 2 (Drill-Tec 3 in. Min. 22 ga., DensDeck Primer: GAF SA Primer Insulation: Min. 1.5-inch EnergyGuard Polyiso GAF 2-Part, Type B, Prime or Ribbed Galvalume 1 per Vapor Retarder: GAF SA Insulation or EnergyGuard RA LRF-M, LRF- EverGuard TPO / TPO QSA 5-196. Grade 33 SECUROCK Plate (Flat) may be 2.0 ft2 Vapor Retarder, self- Coverboard: Min. 0.25-inch DensDeck Prime or XF or or TPO QSA LV50 -67.5 steel Gypsum Fiber used) (no recessed adhering SECUROCK Gypsum -Fiber Roof Board OB500 Roof Board plate) EverGuard TPO / FastLayn TPO Adhesive: Min. 22 ga., Min. 0.5-inch Note 2 One or more layers, any combination, min. 1.5- Type B, SECUROCK (Drill-Tec3 in. Ribbed 1 per Liberty SBS Self -Adhering inch EnergyGuard Polyiso Insulation, EverGuard TPO / FastLayn 5-197. Grade 33 Gypsum -Fiber Galvalume Plate 2.7 ft2 Cap Sheet, self -adhering EnergyGuard RA, min. 0 DensDeck Prime OB500 TPO Adhesive -45.0* or SECUROCK Gypsum-FiberRoof Board and steel Roof Board (Flat) may be used) min. 0.5-inch EnergyGuard HD Polyiso Insulation Min. 22 ga., Note 2 Two plies GAFGLAS Ply 4, 5-198. Type B, Min. 0.625-inch (Drill-Tec3 in. Ribbed 1 per GAFGLAS Ply 4 M applied Min. 1.5-inch EnergyGuard RA hot asphalt EverGuard TPO /FastLayn -45.0* Grade 33 steel DensDeck Galvalume Plate (Flat) may be used) 4.0 ft2 in hot asphalt or OB500 TPO Adhesive 0.5-inch Primer: GAF SA Primer or One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5-inch thick Min. 22 ga., DensDeck Note 2 Matrix 307 Premium EnergyGuard Polyiso Insulation GAF 2-Part, Type B, Prime or (Drill-Tec3 in. Ribbed 1 per Asphalt Primer LRF-M, LRF- EverGuard TPO /FastLayn 5-199. Grade 33 SECUROCK Galvalume Plate 4.0 ft2 Vapor Retarder: GAF SA (Optional) Min. 0.25-inch DensDeck Prime or or TPO Adhesive -45.0* steel Gypsum Fiber (Flat) may be used) Vapor Retarder, self- SECXF Gypsum -Fiber Roof Board or min. 0.5- OBS00 Roof Board adhering inch En inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation One or more layers, base layer min. 1-inch thick, 0.5-inch optional subsequent layer(s) min. 1.5-inch thick Min. 22 ga., DensDeck Note 2 Primer: GAF SA Primer EnergyGuard Polyiso Insulation GAF 2-Part, Type B, yp Prime or (Drill-Tec3 in. Ribbed 1 per Vapor Retarder: GAF SA LRF- EverGuard /FastLayn 5-200. Grade 33 SECUROCK Galvalume Plate 2.0 ft2 Vapor Retarder, self- Min. 0.25-inch DensDeck Prime or SECUROCK XF or XF or TPO Adhesive Adhesive -60.0 steel Gypsum Fiber (Flat) may be used) adhering Gypsum -Fiber Roof Board or min. inch OB500 Roof Board or EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation 0.5-inch Min. 22 ga., DensDeck Note 2 Primer: GAF SA Primer One or more layers, base layer min. 1-inch thick, GAF 2-Part, 5-201. Type B, yp Prime or (Drill-Tec3 in. Ribbed 1 per Vapor Retarder: GAF SA optional subsequent layer(s) min. 1.5-inch thick LRF-M, LRF- EverGuard TPO /FastLayn _67.5 Grade 33 SECUROCK Galvalume Plate 2.0 ft2 Vapor Retarder, self- EnergyGuard Polyiso Insulation XF or TPO Adhesive steel Gypsum Fiber (Flat) may be used) adhering OB500 Roof Board EverGuard TPO Fleece -Back Membrane: NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 44 of 156 *NEMO I etc. TABLE 21): STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) TYPE B-2: MECHANICALLY ATTACHED BONDEDSYSTEM THERMAL BARRIER, TEMP ROOF,BONDED TOP INSULATION, BONDED ROOF COVER System Deck Thermal Barrier Insulation Layer(s) MDP Type Fasten (Note 11) Attach Type Attach No. (Note 1) Temp Roof Roof Cover (Note 15) (psf) (Notes 6,7,8) Min. 22 ga., Note 2 (Drill-Tec 3 in. Grade 33 Min. inch Ribbed Galvalume Min. 1.5-inch EnergyGuard Polyiso Insulation, 5-202. steel or min. SECUROCK Plate (Flat) may be 1 per Liberty SBS Self -Adhering EnergyGuard Ultra, EnergyGuard RA, OB500 EverGuard TPO Fleece- -45.0* 2,500 psi Gypsum -Fiber used) (no recessed 2.7 ft2 Cap Sheet, self -adhering EnergyGuard RN, EnergyGuard RH Back Membrane / WB181 structural Roof Board plate) concrete Min. 22 ga., Note 2 (Drill-Tec 3 in. Min. 1.5-inch EnergyGuard Polyiso Insulation, Grade 33 Min. 0.5-inch Ribbed Galvalume EnergyGuard Ultra, EnergyGuard RA, 5-203. steel or min. SECUROCK Plate (Flat) may be 1 per Liberty SBS Self -Adhering EnergyGuard RN, EnergyGuard RH followed by OB500 EverGuard TPO Fleece- -45.0* 2,500 psi Gypsum -Fiber used) (no recessed 2.7 ft i Cap Sheet, self -adhering min. 0.25-inch DensDeck Prime or SECUROCK Back Membrane / WB181 structural Roof Board plate) Gypsum -Fiber Roof Board concrete Min. 2ga., Note 2 (Drill-Tec 3 in. 3 Grade 33 Min. 0.5-inch Ribbed Galvalume Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece- 5-204. steel or min. SECUROCK Plate (Flat) may be 1 per Liberty SBS Self -Adhering EnergyGuard Ultra, EnergyGuard RA, OB500 Back Membrane / LRF-M -45.0* 2,500 psi Gypsum -Fiber used) (no recessed 2.7 ft Cap Sheet, self -adhering EnergyGuard RN, EnergyGuard RH or LRF-0, 12-inch o.c. structural Roof Board plate) concrete Min. 22 ga., Note 2 (Drill-Tec 3 in. Min. 1.5-inch EnergyGuard Polyiso Insulation, Grade 33 Min. 0.5-inch Ribbed Galvalume EnergyGuard Ultra, EnergyGuard RA, EverGuard TPO Fleece - 5-205. steel or min. SECUROCK Plate (Flat) may be 1 per Liberty SBS Self -Adhering EnergyGuard RN, EnergyGuard RH followed by OB500 Back Membrane /LRF-M -45.0* 2,500 psi Gypsum -Fiber used) (no recessed 2.7 ft2 Cap Sheet, self -adhering min. 0.25-inch SECUROCK Gypsum -Fiber Roof or LRF-O, 12-inch o.c. structural Roof Board plate) Board concrete Min. 22 ga., Note 2 (Drill-Tec 3 in. Grade 33 Min. 0.5-inch Ribbed Galvalume Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece- 5-206. min. SECUROCK Plate (Flat) may be 1 per Liberty SBS Self -Adhering EnergyGuard Ultra, EnergyGuard RA, OB500 Back Membrane /LRF-O, -45.0* 2,500 psi 2,500 p Gypsum Gypsum -Fiber used) (no recessed 2.7 ft2 Cap Sheet, self -adhering EnergyGuard RN, EnergyGuard RH followed by 12-inch o.c. structural Roof Board plate) min. 0.25-inch DensDeck Prime concrete 0.5-inch Note 2 (Drill-Tec 3 in. Primer: GAF SA Primer or One or more layers, base layer min. , 1-inch thick EverGuard TPO Fleece - Min. 22 ga., DensDeck Ribbed Galvalume Matrix 307 Premium optional subsequent layer(s) min. 1.5-inch thick Back Membrane / WB181, 5-207. Type B, Prime or Plate (Flat) may be 1 per Asphalt Primer EnergyGuard RN LRF-M or LRF-M (12-inch o.c.), LRF-O -45.0* Grade 33 SECUROCK used no recessed ) ( 4.0 ft2 Vapor Retarder: GAF SA (Optional) Min. inch DensDeck Prime or OB500 GAF (spatter steel Gypsum Fiber Vapor Retarder, self- , LRF paPart (spatter), LRF-XF (spatter) Roof Board plate) adhering um- SECUROCK Gypsum -Fiber Roof Board or OB500 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 45 of 156 *NEMO I etc. TABLE 21): STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF,BONDED TOP INSULATION, BONDED ROOF System Deck Thermal Barrier Insulation Layer(s) MDP Type Fasten (Note 11) Attach Type Attach No. (Note 1) Temp Roof Roof Cover (Note 15) (Psf) (Notes 6,7,8) 0.5-inch Note 2 (Drill-Tec 3 in. Primer: GAF SA Primer or One or more layers, base layer min. 1-inch thick, EverGuard TPO Fleece - Min. 22 ga., DensDeck Matrix 307 Premium optional subsequent layer(s) min. 1.5-inch thick GAF 2-Part, Back Membrane / WB181, Type B, Prime or Ribbed Galvalume 1 per Asphalt Primer EnergyGuard Polyiso Insulation, EnergyGuard LRF-M, LRF- LRF-M (12-inch o.c.), LRF-O 5-208. Grade 33 SECUROCK Plate (Flat) may be 4.0 ft2 Vapor Retarder: GAF SA Ultra Polyiso Insulation XF or (12-inch o.c.), GAF 2-Part -45.0* steel Gypsum Fiber used) (no recessed Vapor Retarder, self- (Optional) Min. 0.25-inch DensDeck Prime or OB500 (spatter), LRF-XF (spatter) Roof Board plate) adhering SECUROCK Gypsum -Fiber Roof Board or OB500 (spatter) 0.5-inch Note 2 (Drill-Tec 3 in. One or more layers, base layer min. 1-inch thick, Min. 22 ga., DensDeck Ribbed Galvalume Primer: GAF SA Primer optional subsequent layer(s) min. 1.5-inch thick GAF 2-Part, 5-209. Type B, Prime or Plate (Flat) may be 1 per Vapor Retarder: GAF SA EnergyGuard Polyiso Insulation, EnergyGuard LRF-M, LRF- EverGuard TPO Fleece- -52.5 Grade 33 SECUROCK used) (no recessed 2.0 ft2 Vapor Retarder, self- Ultra Polyiso Insulation followed by Min. 0.25- XF or Back Membrane / WB181 steel Gypsum Fiber plate) adhering inch DensDeck Prime OB500 Roof Board 0.5-inch Note 2 (Drill-Tec 3 in. EverGuard TPO Fleece - Min. 22 ga., DensDeck Ribbed Galvalume Primer: GAF SA Primer One or more layers, base layer min. 1-inch thick, GAF 2-Part, Back Membrane / LRF-M 5-210. Type B, Prime or Plate (Flat) may be 1 per Vapor Retarder: GAF SA optional subsequent layer(s) min. 1.5-inch thick LRF-M, LRF- (12-inch o.c.), LRF-O (12- -60.0 Grade 33 SECUROCK used) (no recessed 2.0 ft2 Vapor Retarder, self- EnergyGuard Polyiso Insulation, EnergyGuard XF or inch o.c.), GAF 2-Part steel Gypsum Fiber VP plate) adheringUltra Polyiso Insulation y OB500(spatter), LRF-XF s (spatter) ) Roof Board orr) or OB500 (spatter) 0.5-inch Note 2 (Drill-Tec 3 in. One or more layers, base layer min. 1-inch thick, Min. 22 ga., DensDeck Ribbed Galvalume Primer: GAF SA Primer optional subsequent layer(s) min. 1.5-inch thick GAF 2-Part, EverGuard TPO Fleece - 5-211. Type B, Prime or Plate (Flat) may be 1 per Vapor Retarder: GAF SA EnergyGuard Polyiso Insulation, EnergyGuard LRF-M, LRF- Back Membrane / LRF-M -60.0 Grade 33 SECUROCK used) (no recessed 2.0 ft2 Vapor Retarder, self- Ultra Polyiso Insulation followed by Min. 0.25- XF or (12-inch o.c.) or LRF-0 (12- steel Gypsum Fiber plate) adhering inch DensDeck Prime OB500 inch o.c.) Roof Board 0.5-inch Note 2 (Drill-Tec 3 in. One or more layers, base layer min. 1-inch thick, EverGuard TPO Fleece - Min. 22 ga., DensDeck Ribbed Galvalume Primer: GAF SA Primer optional subsequent layer(s) min. 1.5-inch thick GAF 2-Part, Back Membrane / WB181, 5-212. Type B, Prime or Plate (Flat) may be 1 per Vapor Retarder: GAF SA EnergyGuard Polyiso Insulation, EnergyGuard LRF-M, LRF- LRF-M (4-inch o.c.), LRF-0 -67.5 Grade 33 SECUROCK used) (no recessed 2.0 ft2 Vapor Retarder, self- Ultra Polyiso Insulation followed by Min. 0.25- XF or (4-inch o.c.), GAF 2-Part steel Gypsum Fiber adhering OB500 (spatter), LRF-XF (spatter) Roof Board plate) inch SECUROCK Gypsum -Fiber Roof Board or OB500 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 46 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER ATTACHEDSYSTEM TYPE C-1: MECHANICALLY INSULATION, BONDED ROOF System Base Insulation Layer Top Insulation Layer Roof Cover MDP No. Deck (Note 1) (Note 13) Type Fasten (Note 11) Attach (Note 15) (psf) EverGuard Freedom TPO: Min. 22 ga., Type B, Grade Note 2 5-213. 33 steel or min. 2,500 psi (Optional) One or more Min. 2-inch EnergyGuard Polyiso 6 parts per min. 4 x 8 ft board with parts installed 36-inch o.c. 1 per EverGuard Freedom -30.0* layers, any combination Insulation, EnergyGuard Ultra in two parallel rows, 12 inches from the 8 ft edges of the 5.3 ft2 TPO / self adhered structural concrete board Drill-Tec #12 (steel only) or #14 with Drill-Tec 3" Standard Min. 22 ga., Type B, Grade Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or 5-214. 33 steel or min. 2,500 psi One or more layers, any Min. 0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard Freedom -30.0* combination, min. 1-inch SECUROCK Gypsum -Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fastener or 4.0 ft2 TPO /self adhered structural concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate Min. 22ga., Type B, Grade ( Optional) One or more Min. 1.5-inch EnergyGuard Polyiso 1 per EverGuard Freedom 5-215. el min. 2,500 psi 33 steel layers, any combination Insulation, EnergyGuard Ultra Note 2 2.7 ft2 TPO /self adhered -37.5* structurall concrete Min. 22 ga., Type B, Grade (Optional) One or more Min. 2-inch EnergyGuard RA, 1 per EverGuard Freedom 5-216. 33 steel or min. 2,500 psi layers, any combination EnergyGuard RN, or EnergyGuard Ultra Note 2 3.2 ft' TPO / self adhered -45.0* structural concrete Min. 0.5-inch EnergyGuard RH HD Min. 22 ga., Type B, Grade (Optional) One or more Polyiso Insulation, EnergyGuard HD 1 per EverGuard Freedom 5-217. 33 steel or min. 2,500 psi layers, any combination Polyiso Insulation, EnergyGuard HD Note 2 2.0 ft2 TPO / self adhered _45.0* structural concrete Plus Polyiso Insulation Min. 22 ga., Type B, Grade (Optional) One or more Min. 1.5-inch EnergyGuard Polyiso 1 per EverGuard Freedom 5-218. 33 steel or min. 2,500 psi layers, any combination Insulation, EnergyGuard Ultra Note 2 2.0 ft TPO / self adhered _45.0* structural concrete Min. 22 ga., Type B, Grade Note 2 5-219. 33 steel or min. 2,500 psi (Optional) One or more Min. 2-inch EnergyGuard Polyiso 8 parts per min. 4 x 8 ft board with parts installed 24-inch o.c. 1 per EverGuard Freedom -45.0* layers, any combination Insulation, EnergyGuard Ultra in two parallel rows, 12 inches from the 8 ft edges of the 4.0 ft TPO / self adhered structural concrete board Drill-Tec #12 (steel only) or #14 with Drill-Tec 3" Standard Min. 22 ga., Type B, Grade Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or 5-220. 33 steel or min. 2,500 psi One or more layers, any Min. 0.25-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard Freedom -45.0* combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fasteneror 3.2 ft TPO / self adhered structural concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate Drill-Tec #12 (steel only) or #14 with Drill-Tec 3" Standard Min. 22 ga., Type B, Grade Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or 5-221. 33 steel or min. 2,500 psi One or more layers, any Min. 0.375-inch SECUROCK Gypsum- Drill-Tec AccuTmc Flat Plates or with Drill-Tec ASAP 35 or Drill- 1 per EverGuard Freedom _45.0* combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fasteneror 4.0 ft TPO / self adhered structural concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate Min. 22 ga., Type B, Grade 5-222. 33 steel or min. 2,500 psi (Optional) One or more Min. 2-inch EnergyGuard RA, Note 2 1 per EverGuard Freedom -52.5 layers, any combination EnergyGuard RN, or EnergyGuard Ultra 1.3 ft2 TPO / self adhered structural concrete NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 47 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP No. Deck (Note 1) (Note 13) (Note 15) (psf) Type Fasten (Note 11) Attach Min. 22 ga., Type B, Grade (Optional) One or more Min. 2-inch EnergyGuard RA, 1 per EverGuard Freedom 5-223. 33 steel or min. 2,500 psi layers, any combination EnergyGuard RN, or EnergyGuard Ultra Note 2 (#14 only) 2.0 ft2 TPO /self adhered -52.5 structural concrete Min. 22 ga., Type B, Grade Drill-Tec #12 (steel only) or Drill-Tec #14 Fastener with Drill- 5-224. 33 steel or min. 2,500 psi One or more layers, any Min. 0.25-inch DensDeck Prime Tec 3 in Ribbed Galvalume Plate (Flat) or Drill-Tec #12 DP 1 per EverGuard Freedom -60.0 combination, min. 1-inch Fastener (steel only), Drill-Tec #14 HD Fasteneror Drill-Tec 1.45 ft' TPO / self adhered structural concrete #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate Min. 20 ga., Type B, Grade Drill-Tec #12 (steel only) or Drill-Tec #14 Fastener with Drill- 5-225. 33 steel min. 2,500 psi One or more layers, any Min. 0.25-inch SECUROCK Gypsum- Tec 3 in Ribbed Galvalume Plate (Flat), Drill-Tec #12 DP 1 per EverGuard Freedom -60.0 combination, min. 1-inch Fiber Roof Board Fastener (steel only), Drill-Tec #ia HD Fasteneror Drill-Tec 1.3 ft2 TPO /self adhered structurall concrete #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate Min. 20 ga., Type B, Grade Drill-Tec #12 (steel only) or Drill-Tec #14 Fastener with Drill- 5-226. 33 steel or min. 2,500 psi One or more layers, any Min. 0.375-inch SECUROCK Gypsum- Tec 3 in Ribbed Galvalume Plate (Flat), Drill-Tec #12 DP 1 per EverGuard Freedom -75.0 combination, min. 1-inch Fiber Roof Board Fastener (steel only), Drill-Tec #14 HD Fasteneror Drill-Tec 1.45 ft' TPO / self adhered structural concrete #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate EverGuard TPO / EverGuard TPO #1121 Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Min. 22 ga., Type B, Grade (Optional) One or more Min. 1.5-inch EnergyGuard RA, 1 per EverGuard TPO / 5-227. 33 steel or min. 2,500 psi layers, any combination EnergyGuard RN, EnergyGuard PH Note 2 3.2 ft2 #1121, TPO 3-Square -30.0* structural concrete 5-228. Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi (Optional) One or more Min. 2-inch EnergyGuard Polyiso Note 2 6 parts per min. 4 x 8 ft board with parts installed 36-inch c.c. 1 per EverGuard TPO / -30.0* structural concrete layers, any combination Insulation, EnergyGuard Ultra in two parallel rows, 12 inches from the 8 ft edges of the 5.3 ft2 #1121, TPO 3-Square board Drill-Tec #12 (steel only) or#14with Drill-Tec 3" Standard Min. 22 ga., Type B, Grade Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or 5-229. 33 steel or min. 2,500 psi One or more layers, any Min. 0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard TPO / -30.0* structural concrete combination, min. 1-inch SECUROCK Gypsum -Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fastener or 4.0 ft2 #1121, TPO 3-Square Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso (Optional) One or more Insulation, EnergyGuard Ultra, 1 per EverGuard TPO / 5-230. 33 steel or min. 2,500 psi layers, any combination EnergyGuard RA, EnergyGuard RN, Note 2 2.7 ft' #1121, TPO 3-Square -37.5* structural concrete EnergyGuard RH Min. 22 ga., Type B, Grade (Optional) One or more Min. 0.25-inch SECUROCK Gypsum- 1 per EverGuard TPO / 5-231. 33 steel or min. 2,500 psi layers, any combination Fiber Roof Board Note 2 2.7 ft' #1121, TPO 3-Square -37.5* structural concrete Min. 22 ga., Type B, Grade (Optional) One more 1 per EverGuard / 5-232. 33 steel or min. 2,500 psi layers, any combination Min. 0.25-inch DensDeck Prime Note 2 (Drill-Tec 3"Standard Steel Plate only) 2.7 ft' #1121, TPO 3-Square -45.0* structural concrete Min. 22 ga., Type B, Grade (Optional) One or more Note 2 (Drill-Tec3"Steel Plate or Drill-Tec 3" Flat Steel 1 per EverGuard TPO / 5-233. 33 steel or min. 2,500 psi layers, any combination Min. 0.25-inch DensDeck Prime Plate only) 2.13 ft2 #1121, TPO 3-Square -45.0* structural concrete NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 7'^ Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 48 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP No. Deck (Note 1) (Note 13) (Note 15) (psf) Type Fasten (Note 11) Attach Min. 22 ga., Type B, Grade (Optional) One or more 1 per EverGuard TPO / 5-234. 33 steel or min. 2,500 psi layers, any combination Min. 0.25-inch DensDeck Prime Note 2 2.0 ft2 #1121, TPO 3-Square -45.O* structural concrete Min. 22 ga., Type B, Grade (Optional) One or more Min. 0.5-inch DensDeck or DensDeck 1 per EverGuard TPO / 5-235. 33 steel or min. 2,500 psi layers, any combination Prime Note 2 3.2 ft2 #1121, TPO 3-Square -45.0* structural concrete Min. 22 ga., Type B, Grade (Optional) One more Min. DensDeck or EverGuard IPO / 5-236. 33 steel or min. 2,500 psi bi layers, any combination Deck Pinch DensDeck Prime Note 2 .per 4.0 ft2 #1121, TPO 3-Square 3-S -45.0* structural concrete Min. 22 ga., Type B, Grade (Optional) One more Min. SECUROCK Gypsum- 1 per EverGuard PO / 5-237. 33 steel or min. 2,500 psi bi layers, any combination Fiber Roof Board Roof Note 2 2.0 ft2#1121, TPO 3-Square 3-S -45.0* structural concrete Min. 22 ga., Type B, Grade (Optional) One or more Min. 0.625-inch SECUROCK Gypsum- 1 pe EverGuard TPO / 5-238. 33 steel or min. 2,500 psi layers, any combination Fiber Roof Board Note 2 4.0 ft z #1121, TPO 3-Square -45.0* structural concrete Drill-Tec #12 (steel only) or #14 with Drill-Tec 3" Standard Min. 22 ga., Type B, Grade Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or 5-239. 33 steel or min. 2,500 psi One or more layers, any Min. 0.25-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard TPO / -45.0* combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fastener or 3.2 ft2 #1121, TPO 3-Square structural concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate Drill-Tec #12 (steel only) or#14with Drill-Tec 3" Standard Min. 22 ga., Type B, Grade Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or 5-240. 33 steel or min. 2,500 psi One or more layers, any Min. 0.375-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard TPO / -45.0* combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fastener or 4.0 ft2 #1121, TPO 3-Square structural concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate Min. 22 ga., Type B, Grade (Optional) One or more 1 per EverGuard TPO / 5-241. 33 steel or min. 2,500 psi layers, any combination Min. 7/16-inch OSB Note 2 4.0 ft2 #1121, TPO 3-Square -45.0* structural concrete Min. 22 ga., Type B, Grade (Optional) One or more 1 per EverGuard TPO / 5-242. 33 steel or min. 2,500 psi layers, any combination Min. 7/16-inch OSB Note 2 2.0 ft2 #1121, TPO 3-Square -45.0* structural concrete Min. 22 ga., Type B, Grade One or more layers, any Min. 0.5-inch EnergyGuard RH HD 5-243. 33 steel or min. 2,500 psi combination, min. 1.5- Polyiso Insulation, EnergyGuard HD Note 2 1 per EverGuard TPO / -45.0* structural concrete inch Polyiso Insulation, EnergyGuard HD 2.0 ft2 #1121, TPO 3-Square Plus Polyiso Insulation Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso (Optional) One or more Insulation, EnergyGuard Ultra, 1 per EverGuard TPO / 5-244. 33 steel or min. 2,500 psi layers, any combination EnergyGuard RA, EnergyGuard RN, Note 2 2.0 ft2 #1121, TPO 3-Square -45.0* structural concrete EnergyGuard RH or EnergyGuard Ultra NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 49 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP No. Deck (Note 1) (Note 13) (Note 15) (psf) Type Fasten (Note 11) Attach Note 2 a 1 per Min. 22 ga., Type B, Grade (Optional) One or more Min. 2.5-inch EnergyGuard Polyiso o 0 0 0 0 - 2.3 ft2 (14 EverGuard TPO / S-245. 33 steel or min. 2,500 psi structural concrete layers, any combination Insulation, EnergyGuard Ultra 0 0 0 o parts #1121, TPO 3-Square -45.0 per 4x8 0 0 0 0 o x F ft board) Min. 22 ga., Type B, Grade (Optional) One or more Min. 2-inch EnergyGuard Polyiso Note 2 8 parts per min. 4 x 8 ft board with parts installed 24-inch o.c. 1 per EverGuard TPO / 5-246. steel min. 2,500 psi layers, any combination Insulation, EnergyGuard Ultra in two parallel rows, 12 inches from the 8 ft edges of the 4.0 ft2 #1121, TPO 3-Square -45.0* l structural concrete t board Min. 22 ga., Type B, Grade (Optional) One or more Min. 2-inch EnergyGuard RA, 1 1 per EverGuard and TPIP O / S-247. 33 steel or min. 2,500 psi layers, any combination EnergyGuard RN, EnergyGuard RH or Note 2 ft2 #1121, Square -45.0* structural concrete EnergyGuard Ultra Min. 22ga., Type B, Grade One or more layers, any Min. 0.25-inch DensDeck Prime or 1 per EverGuard TPO / 5-248. 33 steelel min. 2,500 psi combination, min. 1-inch SECUROCK Gypsum -Fiber Roof Board Note 2 1.8 ft2 #1121, TPO 3-Square -52.5 structural concrete Min. 22 ga., Type B, Grade (Optional) One more Min. EnergyGuard Polyiso 1 per EverGuard / S-249. 33 steel or min. 2,500 psi layers, any combination bi tiinch Insulation Note 2 1.8 ft2 #1121, TPO 3-Square 3-S -60.0 structural concrete Note 2 Min. 22 ga., Type B, Grade o 5-250. 33 steel or min. 2,500 psi (Optional) One or more Min. 2.5-inch EnergyGuard Polyiso 1 per EverGuard TPO / -60.0 structural concrete layers, any combination Insulation ® ® ®1 2.0 ft2 #1121, TPO 3-Square ) Min. 22 ga., Type B, Grade (Optional) One more 1 perEverGuard / S-251. 33 steel or min. 2,500 psi layers, any combination Min. 2-inch EnergyGuard RH Note 2 1.8 ft2 #1121, TPO 3-Square 3-S -67.5 structural concrete Min. 20 ga., Type B, Grade (Optional) One or more Min. 2-inch EnergyGuard Polyiso Drill-Tec #12 (steel only) or Drill-Tec #14 Fastener with 1 per EverGuard TPO / 5-252. 33 steel or min. 2,500 psi layers, any combination Insulation or EnergyGuard RH Drill-Tec 3 in Ribbed Galvalume Plate 1.6 ft2 #1121, TPO 3-Square -67.5 structural concrete Min. 22 ga., Type B, Grade One or more layers, any Min. 0.375-inch SECUROCK Gypsum- 1 per EverGuard TPO / 5-253. 33 steel min. 2,500 psi combination, min. 1-inch Fiber Roof Board Note 2 1.3 ft2 #1121, TPO 3-Square -67.5 structurall concrete NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 50 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP No. Deck (Note 1) (Note 13) (Note 15) (psf) Type Fasten (Note 11) Attach Min. 22 ga., Type B, Grade One or more layers, any Min. 0.5-inch Structodek High Density 1 per EverGuard TPO / 5-254. 33 steel or min. 2,500 psi combination, min. 1.5- Roof Fiberboard Note 2 1.0 ft2 #1121, TPO 3-Square -67.5 structural concrete inch Min. 22 ga., Type B, Grade One or more layers, any Min. 0.5-inch SECUROCK Gypsum -Fiber 1 per EverGuard TPO / 5-255. 33 steel or min. 2,500 psi combination, min. 1.5- Roof Board Note 2 1.0 W #1121, TPO 3-Square 97.5 structural concrete inch Min. 22 ga., Type B, Grade One or more layers, any Drill-Tec #12 (steel only), #14 or XHD with Drill-Tec 3 in. 5-256. 80 steel min. psi combination, min. 1.5- Min. 0.5-inch DensDeck Prime Ribbed Galvalume Plates (Flat) or Drill-Tec #12 DP Fastener 1 per EverGuard TPO / -127.5 structurall concreteto inch (steel only), Drill-Tec #14 HD Fastener or Drill-Tec #15 FHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate 1.0 ft2 #1121 EverGuard TPO / EverGuard WB181 Bonding Adhesive: Min. 22 ga., Type B, Grade (Optional) One more Min. 1.5-inch EnergyGuard per EverGuard TPO / 5-257. 33 steel or min. 2,500 psi layers, any combination EnergyGuard RN, EnergyGuardand RH Note 2 3.2 ft2 WB181 -30.0* structural concrete Min. 22 ga., Type B, Grade (Optional) One or more Min. 2-inch EnergyGuard Polyiso Note 2 6 parts per min. 4 x 8 ft board with parts installed 36-inch o.c. 1 per EverGuard TPO / 5-258. 33 steel or min. 2,500 psi layers, any combination Insulation, EnergyGuard Ultra in two parallel rows, 12 inches from the 8 ft edges of the 5.3 ft2 WB181 -30.0* structural concrete board Drill-Tec #12 (steel only) or #14 with Drill-Tec 3" Standard Min. 22 ga., Type B, Grade Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or 5-259. 33 steel or min. 2,500 psi One or more layers, any Min. 0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard TPO / -30.0* combination, min. 1-inch SECUROCK Gypsum -Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fasteneror 4.0 ft2 WB181 structural concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso 5-260. 33 steel or min. 2,500 psi (Optional) One or more Insulation, EnergyGuard Ultra, Note 2 1 per EverGuard TPO / -37.5* structural concrete layers, any combination EnergyGuard RA, EnergyGuard RN, 2.7 ft2 WB181 EnergyGuard RH Min. 22 ga., Type B, Grade (Optional) One o. more 1 per EverGuard TPO / 5-261. 33 steel or min. 2,500 psi layers, any combination Min. 0.25-inch DensDeck Prime Note 2 2.0ft i WB181 -45.0* structural concrete Min. 22 ga., Type B, Grade (Optional) One or more 1 per EverGuard TPO / 5-262. 33 steel or min. 2,500 psi layers, any combination Min. 0.5-inch DensDeck Prime Note 2 3.2 ft2 WB181 -45.0* structural concrete Min. 22 ga., Type B, Grade Drill-Tec #12 (steel only) or #14 with Drill-Tec 3 in. Ribbed 5-263. 33 steel or min. 2,500 psi (Optional) One or more Min. 0.5-inch DensDeck Prime Galvalume Plates (Flat) or Drill-Tec #12 DP Fastener (steel 1 per EverGuard TPO / -45.0* layers, any combination only), Drill-Tec #14 HD Fasteneror Drill-Tec #15 EHD Fastener 4.0 ft2 WB181 structural concrete (steel only) with Drill-Tec 3" Flat Steel Plate Min. 22 ga., Type B, Grade (Optional) One or more 1 per EverGuard TPO / 5-264. 33 steel or min. 2,500 psi layers, any combination Min. 0.625-inch DensDeck Prime Note 2 4.0 ft2 WB181 -45.0* structural concrete NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 51 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Base Insulation Layer ATTACHEDSYSTEM TYPE C-1: MECHANICALLY INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP No. Deck (Note 1) (Note 13) (Note 15) (psf) Type Fasten (Note 11) Attach Min. 22 ga., Type B, Grade (Optional) One or more Min. 0.25-inch SECUROCK Gypsum- 1 per EverGuard TPO / 5-265. 33 steel or min. 2,500 psi layers, any combination Fiber Roof Board Note 2 2.0 ft2 WB181 -45.0* structural concrete Drill-Tec #12 (steel only) or #14 with Drill-Tec 3" Standard Min. 22 ga., Type B, Grade Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or 5-266. 33 steel or min. 2,500 psi One or more layers, any Min. 0.25-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard TPO / _45.0* combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fasteneror 3.2 ft WB181 structural concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate Drill-Tec #12 (steel only) or#14with Drill-Tec 3" Standard Min. 22 ga., Type B, Grade Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or 5-267. 33 steel or min. 2,500 psi One or more layers, any Min. 0.375-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per EverGuard TPO / _45.0* combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fasteneror 4.0 ft WB181 structural concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate Min. 22 ga., Type B, Grade ga an One or more layers, any Min. 0.5-inch EnergyGuard RH HD 5-268. 33 steel min. 2,500 psi combination, min. Polyiso Insulation, EnergyGuard HD Note 2 1 per EverGuard TPO / _45.0* Polyiso Insulation, EnergyGuard HD 2.0ft i WB181 structural concrete inch Plus Polyiso Insulation Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso (Optional) One or more Insulation, EnergyGuard Ultra, 1 pe EverGuard TPO / 5-269. 33 steel or min. 2,500 psi layers, any combination EnergyGuard RA, EnergyGuard RN or Note 2 2.0 ft i WB181 -45.0* structural concrete EnergyGuard RH Min. 22 ga., Type B, Grade Note 2 5-270. 33 steel or min. 2,500 psi (Optional) One or more Min. 2-inch EnergyGuard Polyiso 8 parts per min. 4 x 8 ft board with parts installed 24-inch o.c. 1 per EverGuard TPO / _45.0* structural concrete layers, any combination Insulation, EnergyGuard Ultra in two parallel rows, 12 inches from the 8 ft edges ofthe 4.0 ft2 WB181 board Min. 22 ga., Type B, Grade (Optional) One more Min. 2-inch EnergyGuard RA, per EverGuard TPO / 5-271. 33 steel or min. 2,500 psi layers, any combination EnergyGuard RN or EnergyGuard RH Note 2 2 4.. 0 ft WB181 _45.0* structural concrete Min. 22 ga., Type B, Grade One or more layers, any 1 per EverGuard TPO / 5-272. 33 steel or min. 2,500 psi combination, min. 1.5- Min. 0.25-inch DensDeck Prime Note 2 1.45 ft2 WB181 -52.5 structural concrete inch Min. 22 ga., Type B, Grade One or more layers, any Min. 0.25-inch SECUROCK Gypsum- 1 per EverGuard TPO / 5-273. 33 steel min. psi combination, min. 1-inch Fiber Roof Board Note 2 1.8 ft2 WB181 -52.5 structurall concretteo Min. 22 ga., Type B, Grade One or more layers, any Min. 0.375-inch SECUROCK Gypsum- 1 per EverGuard TPO / 5-274. steel or min. psi combination, min. 1-inch Fiber Roof Board Note 2 1.3 ft2 WB181 -67.5 t ructura stl e concrete s t Min. 22 ga., Type B, Grade One or more layers, any in. 0.5-inch Structodek High Density 1 per EverGuard TPO / 5-275. 33 steel or min. 2,500 psi combination, min. 1.5- Fiberboard Roof Insulation, Fiber Base Note 2 1.0 ft 2 WB181 -67.5 structural concrete inch HDl or Fiber Base HD6 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 52 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP No. Deck (Note 1) (Note 13) (Note 15) (psf) Type Fasten (Note 11) Attach Min. 22 ga., Type B, Grade One or more layers, any Drill-Tec #12 (steel only), #14 or XHD with Drill-Tec 3 in. 5-276. 33 steel or min. 2,500 psi combination, min. 1.5- Min. 0.5-inch DensDeck Prime Ribbed Galvalume Plates (Flat) or Drill-Tec #12 DP Fastener 1 per EverGuard TPO / -75.0 Structural concrete Inch (steel only), Drill-Tec #14 HD Fasteneror Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate 1.6 ft2 WB181 Min. 22 ga., Type B, Grade One or more layers, any Drill-Tec #12 (steel only), #14 or XHD with Drill-Tec 3 in. 5-277. 33 steel or min. 2,500 psi combination, min. 1.5- Min. 0.5-inch DensDeck Prime Ribbed Galvalume Plates (Flat) or Drill-Tec #12 DP Fastener 1 per EverGuard TPO / 82.5 structural concrete inch (steel only), Drill-Tec #14 HD Fasteneror Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate 1.0 ft2 WB181 Min. 22 ga., Type B, Grade One or more layers, any Drill-Tec #12 (steel only), #14 or XHD with Drill-Tec 3 in. 5-278. 80 steel or min. 2,500 psi combination, min. 1.5- Min. 0.5-inch DensDeck Prime Ribbed Galvalume Plates (Flat) or Drill-Tec #12 DP Fastener 1 per EverGuard TPO / -127.5 structural concrete Inch (steel only), Drill-Tec #14 HD Fasteneror Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate 1.0 ft' WB181 EverGuard TPO / EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Min. 22 ga., Type B, Grade (Optional) One or more Min. 1.5-inch EnergyGuard RA, 1 per EverGuard TPO / TPO 5-279. 33 steel or min. 2,500 psi layers, any combination EnergyGuard RN, EnergyGuard RH Note 2 3.2 ft2 6-Square, TPO 3- -30.0* structural concrete Square Min. 22 ga., Type B, Grade Note 2 EverGuard TPO / TPO 5-280. 33 steel or min. 2,500 psi (Optional) One or more Min. 2-inch EnergyGuard Polyiso 6 parts per min. 4 x 8 ft board with parts installed 36-inch o.c. 1 per 6-Square, TPO 3- -30.0* structural concrete layers, any combination Insulation, EnergyGuard Ultra in two parallel rows, 12 inches from the 8 ft edges of the 5.3 ft Square board Drill-Tec #12 (steel only) or #14 with Drill-Tec 3" Standard Min. 22 ga., Type B, Grade Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or EverGuard TPO / TPO 5-281. 33 steel or min. 2,500 psi One or more layers, any Min. 0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per 6-Square, TPO 3- -30.0* combination, min. 1-inch SECUROCK Gypsum -Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fastener or 4.0 ft2 structural concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Square Steel Plate Min. 22 ga., Type B, Grade Min. 1.5-inch EnergyGuard Polyiso EverGuard TPO / TPO 5-282. 33 steel or min. 2,500 psi (Optional) One more Insulation, EnergyGuard Ultra, Note 2 1 per 6-Square, TPO 3- -37.5* layers, any combination b EnergyGuard RA, EnergyGuard RN, 2.7 ft2 structural concrete EnergyGuard RH Square Min. 22 ga., Type B, Grade (Optional) One or more Min. 0.25-inch SECUROCK Gypsum- 1 per EverGuard TPO / TPO 5-283. 33 steel or min. 2,500 psi layers, any combination Fiber Roof Board Note 2 2 7 ft2 6-Square, TPO 3- -37.5* structural concrete Square Min. 22 ga., Type B, Grade (Optional) One or more 1 per per EverGuard TPO / TPO 5-284. 33 steel or min. 2,500 psi layersany combination , Min. 0.25-inch DensDeck Prime Note 2 (Drill-Tec 3" Standard Steel Plate only) 2 7 6-Square, TPO 3- -45.0* structural concrete Square Min. 22 ga., Type B, Grade (Optional) One or more Note 2 (Drill-Tec 3" Steel Plate or Drill-Tec 3" Flat Steel 1 per EverGuard TPO / TPO 5-285. 33 steel or min. 2,500 psi layers, any combination Min. 0.25-inch DensDeck Prime Plate only) 2.13 ft2 6-Square, TPO 3- -45.0* structural concrete Square Min. 22 ga., Type B, Grade (Optional) One or more 1 per EverGuard TPO / TPO 5-286. 33 steel or min. 2,500 psi layers, any combination Min. 0.25-inch DensDeck Prime Note 2 2.0 ft' 6-Square, TPO 3- -45.0* structural concrete Square NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMo ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 53 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP No. Deck (Note 1) (Note 13) (Note 15) (psf) Type Fasten (Note 11) Attach Min. 22 ga., Type B, Grade (Optional) One or more 1 per EverGuard TPO / TPO 5-287. 33 steel or min. 2,500 psi layers, any combination Min. 0.5-inch DensDeck Prime Note 2 3 2 ft2 6-Square, TPO 3- -45.0* structural concrete Square Min. 22 ga., Type B, Grade EverGuard TPO / TPO 5-288. 33 steel or min. 2,500 psi (Optional) One or more Min. 0.625-inch DensDeck Prime Note 2 1 per 6-Square, TPO 3- -45.0* layers, any combination 4.0 ft2 structural concrete Square Min. 22 ga., Type B, Grade (Optional) One or more Min. 0.25-inch SECUROCK Gypsum- 1 per EverGuard TPO / TPO 5-289. 33 steel or min. 2,500 psi layers, any combination Fiber Roof Board Note 2 2.0 ft2 6-Square, TPO 3- -45.0* structural concrete Square Min. 22 ga., Type B, Grade (Optional) One or more Min. 0.625-inch SECUROCK Gypsum- 1 per EverGuard TPO / TPO 5-290. 33 steel min. 2,500 psi layers, any combination Fiber Roof Board Note 2 4.0 ft2 6-Square, TPO 3- -45.0* structurall concrete Square Min. 22 ga., Type B, Grade (ayers, Optional) One or more 1 per EverGuard TPO / TPO 5-291. 33 steel or min. 2,500 psi lany combination Min. 0.25-inch DensDeck Prime Note 2.45 1 ft2 6-Square, TPO 3- -45.0 structural concrete Square Drill-Tec #12 (steel only) or#14 with Drill-Tec 3" Standard Min. ga., Type B, Grade Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or EverGuard TPO TPO 5-292. 33 steeell or min. 2,500 psi One or more layers, any Min. 0.25-inch SECUROCK Gypsum- Drill-Tec Accu7rac Flat Plates or with Drill-Tec ASAP 35 or Drill- 1 per 6-Square, TPO 3-- -45.0* combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fastener or 3.2 ft2 Structural concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Square Steel Plate Drill-Tec #12 (steel only) or#14with Drill-Tec 3" Standard Min. ga., Type B, Grade Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or EverGuard TPO TPO 5-293. 33 steeell or min. 2,500 psi One or more layers, any Min. 0.375-inch SECUROCK Gypsum- Drill-Tec Accu7rac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per 6-Square, TPO 3-- -45.0* combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fastener or 4.0 ft2 Structural concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Square Steel Plate Min. 22 ga., Type B, Grade One or more layers, any Min. 0.5-inch EnergyGuard RH HD EverGuard TPO / TPO 5-294. 33 steel or min. 2,500 psi combination, min. 1.5- Polyiso Insulation, EnergyGuard HD Note 2 1 per 6-Square, TPO 3- -45.0* structural concrete inch Polyiso Insulation, EnergyGuard HD 2.0 ft i Square Plus Polyiso Insulation Min. 22 ., Type B, Grade ga Min. 1.5-inch EnergyGuard Polyiso EverGuard T PO/TPO 5-295. 33 steel or min. 2,500 psi (Optional) One more Insulation, EnergyGuard Ultra, Note 2 6-Square, TPO 3- -45.0* structural concrete layers, any combination EnergyGuard RA, EnergyGuard .per 20 ft2 Square EnergyGuard RH or EnergyGuardd U Ultra NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 54 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP No. Deck (Note 1) (Note 13) (Note 15) (psf) Type Fasten (Note 11) Attach Note 2 a 1 per Min. 22 ga., Type B, Grade o 0 0 0 0 2.3 ft' EverGuard TPO / TPO S-296. 33 steel or min. 2,500 psi (Optional) One or more Min. 2.5-inch EnergyGuard Polyiso - (14 6-Square, TPO 3- -45.0 structural concrete layers, any combination Insulation, EnergyGuard Ultra _ 0 0 0 o parts Square per 4x8 0 0 0 0 o x F ft board) Min. 22 ga., Type B, Grade Note 2 EverGuard TPO / TPO S-297. 33 steel or min. 2,500 psi (Optional) One or more Min. 2-inch EnergyGuard Polyiso 8 parts per min. 4 x 8 ft board with parts installed 24-inch o.c. 1 per 6-Square, TPO 3- -45.0* structural concrete layers, any combination Insulation, EnergyGuard Ultra in two parallel rows, 12 inches from the 8 ft edges ofthe 4.0ft i Square board Min. 22 ga., Type B, Grade (Optional) One or more Min. 2-inch EnergyGuard RA, 1 p per erft2 EverGuard TPO / TPO S-298. 33 steel or min. 2,500 psi layersany combination , EnergyGuard RN, EnergyGuard RH or Note 2 4 0 6-Square, TPO 3- -45.0* structural concrete EnergyGuard Ultra Square Min. 22 ga., Type B, Grade EverGuard TPO / TPO S-299. 33 steel or min. 2,500 psi One or more layers, any Min. 0.25-inch SECUROCK Gypsum- Note 2 1 per 6-Square, TPO 3- -52.5 combination, min. 1-inch Fiber Roof Board 1.8 ft i structural concrete Square Min. 22 ga., Type B, Grade (Optional) One more Min inch EnergyGuard Polyiso 1 per EverGuard TPO / TPO S-300. 33 steel or min. 2,500 psi layers, any combination Insulation atition Note 2 1.8ft2 6-Square, TPO 3- -60.0 structural concrete Square Note 2 Min. 22 ga., Type B, Grade c EverGuard TPO / TPO S-301. 33 steel or min. 2,500 psi (Optional) One or more Min. 2.5-inch EnergyGuard Polyiso 1 per 6-Square, TPO 3- -60.0 layers, any combination Insulation ® ® ®1 2.0ft2 structural concrete Square ) Min. 22 ga., Type B, Grade (Optional) One or more 1 per EverGuard TPO / TPO S-302. 33 steel or min. 2,500 psi layers, any combination Min. 2-inch EnergyGuard RH Note 2 1.8 ft' 6-Square, TPO 3- -67.5 structural concrete Square Min. 20 ga., Type B, Grade (Optional) One or more Min. 2-inch EnergyGuard Polyiso Drill-Tec #12 (steel only) or Drill-Tec #14 Fastener with 1 per EverGuard TPO / TPO 5-303. 33 steel or min. 2,500 psi layers, any combination Insulation, EnergyGuard Ultra Drill-Tec 3 in Ribbed Galvalume Plate 1.6 ft2 6-Square, TPO 3- -67.5 structural concrete Square Min. 22 ga., Type B, Grade EverGuard TPO / TPO S-304. 33 steel or min. 2,500 psi One or more layers, any Min. inch SECUROCK Gypsum- Note 2 1 per 6-Square, TPO 3- -67.5 structural concrete combination, min. 1-inch Roof Fiber Roof Board 1.3 ft2 Square NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 55 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP Deck (Note 1) Type Fasten (Note 11) Attach No. (Note 13) (Note 15) (psf) Min. 22 ga., Type B, Grade One or more layers, any EverGuard TPO / TPO 5-305. 33 steel or min. 2,500 psi combination, min. 1.5- Min. inch Structodek High Density Note 2 1 per 6-Square, TPO 3- -67.5 structural concrete inch Roof Fib Fiberboard Fib 1.0 ft2 Square Min. 22 ga., Type B, Grade One or more layers, any Drill-Tec #12 (steel only), #14 or XHD with Drill-Tec 3 in. 5-306. 33 steel or min. 2,500 psi combination, min. 1.5- Min. 0.5-inch DensDeck Prime Ribbed Galvalume Plates (Flat) or Drill-Tec #12 DP Fastener 1 per EverGuard TPO / TPO -75.0 (steel only), Drill-Tec #14 HD Fastener or Drill-Tec #15 EHD 1.6 ft2 3-Square structural concrete inch Fastener (steel only) with Drill-Tec 3" Flat Steel Plate Min. 22 ga., Type B, Grade One or more layers, any Drill-Tec #12 (steel only), #14 or XHD with Drill-Tec 3 in. 5-307. 80 steel or min. 2,500 psi combination, min. 1.5- Min. 0.5-inch DensDeck Prime Ribbed Galvalume Plates (Flat) or Drill-Tec #12 DP Fastener 1 per EverGuard TPO / TPO -127.5 (steel only), Drill-Tec #14 HD Fasteneror Drill-Tec #15 EHD 1.0 ft2 3-Square structural concrete inch Fastener (steel only) with Drill-Tec 3" Flat Steel Plate EverGuard TPO / EverGuard TPO Quick Spray Adhesive or EverGuard TPO Quick Spray Adhesive LV 50: Min. 22 ga., Type B, Grade One or more layers, any Min. 0.25-inch DensDeck Prime or 1 per EverGuard TPO / TPO 5-308. 33 steel or min. 2,500 psi combination, min. 1-inch SECUROCK Gypsum-Fibrer Roof Board Note 2 1.8 ft2 QSA or TPO QSA LV50 -52.5 structural concrete Min. 22 ga., Type B, Grade Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastener or 5-309. 33 steel or min. 2,500 psi (Optional) One or more Min. 2-inch EnergyGuard RA Drill-Tec XHD Fastener (steel only) with Drill-Tec 3" Standard 1 per EverGuard TPO / TPO -60.0 layers, any combination Steel Plate, Drill-Tec 3" Steel Plate or Drill-Tec AccuTrac Flat 1.45 ft2 QSA LV50 structural concrete Plate Min. 22 ga., Type B, Grade Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastener or 5-310. 33 steel or min. 2,500 psi (Optional) One or more Min. 2-inch EnergyGuard RA Drill-Tec XHD Fastener (steel only) with Drill-Tec 3" Standard 1 per EverGuard TPO / TPO -75.0 layers, any combination Steel Plate, Drill-Tec 3" Steel Plate or Drill-Tec AccuTrac Flat 1.45 ft2 QSA structural concrete Plate Min. 22 ga., Type B, Grade Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastener or 5-311. 33 steel or min. 2,500 psi (Optional) One or more Min. 2-inch EnergyGuard Polyiso Drill-Tec XHD Fastener (steel only) with Drill-Tec 3" Standard 1 per EverGuard TPO / TPO 82 5 layers, any combination Insulation Steel Plate, Drill-Tec 3" Steel Plate or Drill-Tec AccuTrac Flat 1.45 ft2 QSA or TPO QSA LV50 structural Concrete Plate Min. 22 ga., Type B, Grade (Optional) One or more Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastener or 1 per EverGuard TPO / TPO 5-312. 33 steel or min. 2,500 psi layers, any combination, Min. 0.25-inch DensDeck Prime Drill-Tec XHD Fastener (steel only) with Drill-Tec 3" Standard 82.5 structural concrete min. 2-inch Steel Plate or Drill-Tec AccuTrac Flat Plate 1.45 ft2 QSA or TPO QSA LV50 Min. 22 ga., Type B, Grade (Optional) One or more Min. 0.25-inch SECUROCK Gypsum- Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastener or 1 per EverGuard TPO / TPO 5-313. 33 steel or min. 2,500 psi layers, any combination, Fiber Roof Board Drill-Tec XHD Fastener (steel only) with Drill-Tec AccuTrac Flat 1.45 ft2 QSA or TPO QSA LV50 -82.5 structural concrete min. 2-inch Plate EverGuard TPO / FastLayn TPO Adhesive: Min. 22 ga., Type B, Grade Note 2 5-314. 33 steel or min. 2,500 psi (Optional) One or more Min. 2-inch EnergyGuard Polyiso 6 parts per min. 4 x 8 ft board with parts installed 36-inch o.c. 1 per EverGuard TPO / 30.0* layers, any combination Insulation in two parallel rows, 12 inches from the 8 ft edges of the 5.3 ft2 FastLayn TPO Adhesive structural concrete board Min. 22 ga., Type B, Grade One or more layers, any Min. 0.25-inch DensDeck Prime or 1 per EverGuard TPO / 5-315. 33 steel or min. 2,500 psi Note 2 structural concrete combination, min. 1-inch SECUROCK Gypsum -Fiber Roof Board 4.0 ft2 FastLayn TPO Adhesive�i�] NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 56 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP No. Deck (Note 1) (Note 13) (Note 15) (psf) Type Fasten (Note 11) Attach Min. 22 ga., Type B, Grade (Optional) One or more 1 per EverGuard TPO / 5-316. 33 steel or min. 2,500 psi layers, any combination Min. 1.5-inch EnergyGuard RA Note 2 3.2 ft2 FastLayn TPO Adhesive -30.0* structural concrete Min. 22 ga., Type B, Grade One or more layers, any Min. 0.5-inch EnergyGuard HD Polyiso 1 per EverGuard TPO / 5-317. 33 steel or min. 2,500 psi combination Insulation Note 2 3.2 ft2 FastLayn TPO Adhesive -30.0* structural concrete Min. 22 ga., Type B, Grade (Optional) One or more Min. 1.5-inch EnergyGuard Polyiso 1 per EverGuard TPO / 5-318. 33 steel or min. 2,500 psi layers, any combination Insulation, EnergyGuard RA Note 2 ft 2.7 ' FastLayn TPO Adhesive -37.5* structural concrete Min. 22 ga., Type B, Grade One or more layers, any Min inch EnergyGuard HD Polyiso 1 per EverGuard / 5-319. 33 steel or min. 2,500 psi combination Insulation atiodo n Note 2 2.7 ft2 FastLayn TPOO AAdhesive -37.5* structural concrete Min. 22 ga., Type B, Grade (Optional) One or more Min. 0.25-inch SECUROCK Gypsum- 1 pe EverGuard TPO / 5-320. 33 steel or min. 2,500 psi layers, any combination Fiber Roof Board Note 2 2.7 ft2 FastLayn TPO Adhesive -37.5* structural concrete Min. 22 ga., Type B, Grade (Optional) One or more Min. 2-inch EnergyGuard RA or Min. 1 per EverGuard TPO / 5-321. 33 steel or min. 2,500 psi layers, any combination 0.625-inch DensDeck Prime or Note 2 4.0 ft2 FastLayn TPO Adhesive -45.0* structural concrete SECUROCK Gypsum -Fiber Roof Board Min. 22 ga., Type B, Grade (Optional) One or more 1 per EverGuard TPO / 5-322. 33 steel or min. 2,500 psi layers, any combination Min. 0.5-inch DensDeck Prime Note 2 3.2 ft2 FastLayn TPO Adhesive -45.0* structural concrete 1 per 2.3 ft' Min. 22 ga., Type B, Grade(14 (Optional) One more Min. inch EnergyGuard Polyiso EverGuard PO 5-323. 33 steel or min. 2,500 psi Note 2 parts -45.0 structural concrete layers, any combination bi Insulation do per 4x8 O A/ FastLayn TPO Adhesive ft board) Min. 22 ga., Type B, Grade (Optional) One or more Min. 2-inch EnergyGuard Polyiso Note 2 8 parts per min. 4 x 8 ft board with parts installed 24-inch o.c. 1 per EverGuard TPO / 5-324. 33 steel or min. 2,500 psi layers, any combination Insulation in two parallel rows, 12 inches from the 8 ft edges of the 4.0 ft' FastLayn TPO Adhesive -45.0* structural concrete board Min. 22 ga., Type B, Grade (Optional) One or more 1 per EverGuard TPO / 5-325. 33 steel or min. 2,500 psi layers, any combination Min. 0.25-inch DensDeck Prime Note 2 (Drill-Tec 3"Standard Steel Plate only) 2 7 ft' FastLayn TPO Adhesive -45.0* structural concrete Min. 22 ga., Type B, Grade (Optional) One or more Note 2 (Drill-Tec3"Steel Plate, Drill-Tec3" Flat Steel 1 per EverGuard TPO / 5-326. 33 steel min. 2,500 psi layers, any combination Min. 0.25-inch DensDeck Prime plate or Drill-Tec 3"Recessed Steel Plate only) 2.13 ft2 FastLayn TPO Adhesive -45.0* l structural concrete NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 7'^ Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMD ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 57 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MOP No. Deck (Note 1) (Note 13) (Note 15) (psf) Type Fasten (Note 11) Attach Min. 1.5-inch EnergyGuard Polyiso Min. 22 ga., Type B, Grade ga Insulation, EnergyGuard RA, Min. 0.25- ( Optional) One or more inch DensDeck Prime or SECUROCK 1 per EverGuard TPO / 5-327. 33 steel min. 2,500 psi layers, any combination Gypsum -Fiber Roof Board or Min. 0.5- Note 2 2.0 ft2FastLayn TPO Adhesive _q5.0* structural concrete inch EnergyGuard HD Polyiso Insulation Min. 22ga., Type B, Grade One or more layers, any Min. 0.25-inch DensDeck Prime or 1 per EverGuard TPO / 5-328. 33 steelel min. 2,500 psi combination, min. 1-inch SECUROCK Gypsum -Fiber Roof Board Note 2 1.8 ft2 FastLayn TPO Adhesive -52.5 structural concrete Min. 22 ga., Type B, Grade Min. 0.25-inch DensDeck Prime or One or more layers, any SECUROCK Gypsum -Fiber Roof Board 1 per EverGuard TPO / 5-329. 33 steel min. 2,500 psi combination or min. 0.5-inch EnergyGuard HD Note 2 1.45 ft2 FastLayn TPO Adhesive -60.0 structurall concrete Polyiso Insulation Min. 22 ga., Type B, Grade (Optional) One or more Min. 2-inch EnergyGuard Polyiso 1 pe EverGuard TPO / 5-330. 33 steel or min. 2,500 psi layers, any combination Insulation Note 2 1.8 ft2FastLayn TPO Adhesive -67.5 structural concrete Min. 22 ga., Type B, Grade (Optional) One or more Min. 2-inch EnergyGuard Polyiso 1 per EverGuard TPO / 5-331. 33 steel or min. 2,500 psi layers, any combination Insulation Note 2 1.45 ft2 FastLayn TPO Adhesive 82.5 structural concrete Min. 22 ga., Type B, Grade (Optional) One or more Min. 2-inch EnergyGuard Polyiso 1 per EverGuard TPO / 5-332. 40 steel or min. 2,500 psi layers, any combination Insulation Note 2 1.45 ft2 FastLayn TPO Adhesive -90.0 structural concrete Triposite Roofing System: Min. 22 ga., Type B, Grade (Optional) One or more Min. 1.5-inch EnergyGuard Polyiso 1 per Triposite System / 5-333. 33 steel or min. 2,500 psi layers, any combination Insulation, EnergyGuard Ultra, Note 2 2.0 ft2 Note 15C -45.0* structural concrete EnergyGuard RA or EnergyGuard RN Min. 22 ga., Type B, Grade (Optional) One more Min. 2-inch EnergyGuard Polyiso pe Triposite System / 5-334. 33 steel or min. 2,500 psi layers, any combbination Insulation, EnergyGuard Ultra, Note 2 3. 2 ft z Note 15C _45.0* structural concrete EnergyGuard RA or EnergyGuard RN Min. 22 ga., Type B, Grade (Optional) One more Min. 2-inch EnergyGuard Polyiso per Triposite System / 5-335. 33 steel or min. 2,500 psi layers, any combbination Insulation, EnergyGuard Ultra or Note 2 2. .0 ft Note 15C -60.0 structural concrete EnergyGuard RA Min. 22 ga., Type B, Min. 2-inch EnergyGuard Polyiso Grade 33 steel or min. (Optional) One or more 1 per Triposite System / 5-336. 2,500 psi structural layers, any combination Insulation, EnergyGuard Ultra or Note 2 1.45 ft2 Note 15C -75.0 EnergyGuard RA concrete HYBRID ROOFING SYSTEM: NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 58 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM System Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP Deck (Note 1) No. (Note 13) Type Fasten (Note 11) Attach (Note 15) (psf) Min. 22 ga., Type B, Min. 0.25-inch DensDeck, DensDeck Grade 33 steel or min. (Optional) One or more 1 per Hybrid System / Note 5-337. 2,500 psi structural layers, any combination prime or SECUROCK Gypsum -Fiber Note 2 i _qS.O* 4.0 ft 15D concrete Roof Board EverGuard TPO Fleece -Back Membrane in Hot Asphalt: Min. 22 ga., Type B, EverGuard TPO Fleece- 5-338. Grade 33 steel or min. (Optional) One or more Min. 0.25-inch DensDeck Prime Note 2 1 per Back Membrane / Hot -45.0* 2,500 psi structural layers, any combination 1.8 ft' concrete asphalt EverGuard TPO Fleece -Back Membrane in EverGuard WB181 Bonding Adhesive: Min. 22 ga., Type B, EverGuard TPO Fleece- 5-339. Grade 33 steel or min. (Optional) One or more Min. 1.5-inch EnergyGuard RA, Note 2 1 per Back Membrane / -30.0* 2,500 psi structural layers, any combination EnergyGuard RN, EnergyGuard RH 3.2 ft' concrete WB181 Min. 22 ga., Type B, Note 2 EverGuard TPO Fleece - 5-340. Grade 33 steel or min. (Optional) One or more Min. 2-inch EnergyGuard Polyiso 6 parts per min. 4 x 8 ft board with parts installed 36-inch o.c. 1 per Back Membrane / -30.0* 2,500 psi structural layers, any combination Insulation, EnergyGuard Ultra in two parallel rows, 12 inches from the 8 ft edges of the 5.3 ft2 concrete board WB181 Drill-Tec #12 (steel only) or #14 with Drill-Tec 3" Standard Min. 22 ga., Type B, Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or EverGuard TPO Fleece- 5-341. Grade 33 steel or min. One or more layers, any Min. 0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates orwith Drill-Tec ASAP 3S or Drill- 1 per Back Membrane / -30.0* 2,500 psi structural combination, min. 1-inch SECUROCK Gypsum -Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fasteneror 4.0 ft' concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat WB181 Steel Plate Min. 22 ga., Type B, Min. 1.5-inch EnergyGuard Polyiso Grade 33 steel or min. (Optional) One or more Insulation, EnergyGuard Ultra, 1 per EverGuard TPO Fleece - 5-342. 2,500 psi structural layers, any combination EnergyGuard RA, EnergyGuard RN, Note 2 2.7 ft2 Back Membrane / -37.5* concrete EnergyGuard RH WB181 Min. 22 ga., Type B, Min. 1.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- 5-343. Grade 33 steel or min. (Optional) One or more Insulation, EnergyGuard Ultra, Note 2 1 per Back Membrane / -45.0* 2,500 psi structural layers, any combination EnergyGuard RA, EnergyGuard RN, 2.0 ft' concrete EnergyGuard RH WB181 Min. 22 ga., Type B, Note 2 EverGuard TPO Fleece- 5-344. Grade 33 steel or min. (Optional) One or more Min. 2-inch EnergyGuard Polyiso 8 parts per min. 4 x 8 ft board with parts installed 24-inch o.c. 1 per Back Membrane / -45.0* 2,500 psi structural layers, any combination Insulation, EnergyGuard Ultra in two parallel rows, 12 inches from the 8 ft edges ofthe 4.0ft2 concrete board WB181 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 59 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP Deck (Note 1) Type Fasten (Note 11) Attach No. (Note 13) (Note 15) (psf) Drill-Tec #12 (steel only) or #14 with Drill-Tec 3" Standard Min. 22 ga., Type B, Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or EverGuard TPO Fleece- 5-345. Grade 33 steel or min. One or more layers, any Min. 0.25-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per Back Membrane / -45.0* 2,500 psi structural combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fasteneror 3.2 ft2 concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat WB181 Steel Plate Drill-Tec #12 (steel only) or #14 with Drill-Tec 3" Standard Min. 22 ga., Type B, Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or EverGuard TPO Fleece - 5-346. Grade 33 steel or min. One or more layers, any Min. 0.375-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per Back Membrane / -45.0* 2,500 psi structural combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fasteneror 4.0 ft2 concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat W 6181 Steel Plate Min. 22 ga., Type B, EverGuard TPO Fleece- 5-347. Grade 33 steel or min. One or more layers, any Min. 0.25-inch SECUROCK Gypsum- Note 2 1 per Back Membrane / -52.5 2,500 psi structural combination, min. 1-inch Fiber Roof Board 1.8 ft2 concrete WB181 Min. 22 ga., Type B, EverGuard TPO Fleece - 5-348. Grade 33 steel or min. One or more layers, any Min. 0.375-inch SECUROCK Gypsum- Note 2 1 per Back Membrane / -67.5 2,500 psi structural combination, min. 1-inch Fiber Roof Board 1.3 ft2 concrete WB181 EverGuard TPO Fleece -Back Membrane in LRF Adhesive M or LRF Adhesive O: Min. 22 ga., Type B, EverGuard TPO Fleece- Grade 33 steel or min. (Optional) One or more Min. 2-inch EnergyGuard Polyiso 1 per Back Membrane / LRF- 5-349. 2,500 psi structural layers, any combination Insulation, EnergyGuard Ultra Note 2 4.0 W M or LRF-O, 12-inch _30.0* concrete O.C. Min. 22 ga., Type B, Min. 1.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- Grade 33 steel or min. (Optional) One or more Insulation, EnergyGuard Ultra, 1 per Back Membrane / LRF- 5-350. 2,500 psi structural layers, any combination EnergyGuard RA, EnergyGuard RN, Note 2 2.7 ft2 M or LRF-O, 12-inch _37.5* concrete EnergyGuard RH O.C. Min. 22 ga., Type B, EverGuard TPO Fleece- Grade 33 steel or min. (Optional) One or more Min. 2-inch EnergyGuard RA, 1 per Back Membrane / LRF- 5-351. 2,500 psi structural layers, any combination EnergyGuard RN, EnergyGuard RH Note 2 4.0 ft2 M or LRF-O, 12-inch _37.5* concrete O.C. Min. 22 ga., Type B, EverGuard TPO Fleece - 5-352. Grade 33 steel or min. (Optional) One or more Min. 1.75-inch ACFoam Composite/GB Note 2 1 per Back Membrane / LRF- -37.5* 2,500 psi structural layers, any combination 5.3 ft2 concrete M, 12-inch o.c. Min. 22 ga., Type B, EverGuard TPO Fleece- Grade 33 steel or min. One or more layers, any Min. 0.25-inch Temple Green Glass Note 2 (Drill-Tec 3" Standard Steel Plate or AccuTrac 1 per Back Membrane / LRF- 5-353. 2,500 psi structural combination Primed Roof Board Flat Plate only) 2.0 ft2 M or LRF-O, 12-inch _37.5* concrete O.C. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 60 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP No. Deck (Note 1) (Note 13) (Note 15) (psf) Type Fasten (Note 11) Attach Min. 22 ga., Type B, EverGuard TPO Fleece- 5-354. Grade 33 steel or min. One or more layers, any Min. 0.25-inch DensDeck Prime Note 2 (Drill-Tec3"Standard Steel Plate, AccuTrac Flat 1 per Back Membrane / LRF- -37.5* 2,500 psi structural combination Plate or Drill-Tec3" Flat Steel Plate only) 2.0 ft2 concrete M,12-inch o.c. Min. 22 ga., Type B, Min. 1.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- Grade 33 steel or min. (Optional) One or more Insulation, EnergyGuard Ultra, 1 per Back Membrane / LRF- S-355. 2,500 psi structural layers, any combination EnergyGuard RA, EnergyGuard RN, Note 2 2.0 ft2 M or LRF-O, 12-inch _45.0* concrete EnergyGuard RH O.C. Note 2 w �o I per Min. 22 ga., Type B, 0 0 0 0 2.3 ft2 EverGuard TPO Fleece - Grade 33 steel or min. (Optional) One or more Min. 2.5-inch EnergyGuard Polyiso - (14 Back Membrane / LRF- 5-356. 2,500 psi structural layers, any combination Insulation, EnergyGuard Ultra 0 0 0 o parts M or LRF-0, 12-inch -45.0 concrete per4x8 O.L. 0 0 0 0 0 x F ftboard) Min. 22 ga., Type B, Min. 2-inch EnergyGuard Polyiso EverGuard TPO Fleece - 5-357. Grade 33 steel or min. (Optional) One or more Insulation, EnergyGuard Ultra, Note 2 1 per Back Membrane / LRF- -45.0* 2,500 psi structural layers, any combination EnergyGuard RA, EnergyGuard RN, 2.9 ft2 M or LRF-0, 12-inch concrete EnergyGuard RH O.C. Min. 22 ga., Type B, EverGuard TPO Fleece - 5-358. Grade 33 steel or min. (Optional) One or more Min. 1.75-inch ACFoam Composite/GB Note 2 1 per Back Membrane / LRF- -45.0* 2,500 psi structural layers, any combination 5.3 ft2 concrete 0, 12-inch o.c. Min. 22 ga., Type B, EverGuard TPO Fleece - S-359. Grade 33 steel or min. One or more layers, any Min. 0.25-inch DensDeck Prime Note 2 (Drill-Tec 3" Standard Steel Plate, AccuTrac Flat 1 per Back Membrane/LRF- -45.0* 2,500 psi structural combination Plate or Drill-Tec3" Flat Steel Plate only) 2.0 ft2 0, 12-inch o.c. concrete Min. 22 ga., Type B, EverGuard TPO Fleece- Grade 33 steel or min. One or more layers, any Min. 0.25-inch SECUROCK Gypsum- Note 2 (Drill-Tec 3" Standard Steel Plate, AccuTrac Flat 1 per Back Membrane / LRF- S-360. 2,500 psi structural combination Fiber Roof Board Plate or Drill-Tec 3" Flat Steel Plate only) 2.0 ft2 M or LRF-0, 12-inch _45.0* concrete O.C. Min. 22 ga., Type B, EverGuard TPO Fleece- Grade 33 steel or min. (Optional) One or more 1 per Back Membrane / LRF- S-361. 2,500 psi structural layers, any combination Min. 2-inch EnergyGuard RH Note 2 (Drill-Tec 3" Steel Plate only) 1.8 ft2 M or LRF-0, 12-inch -52.5 concrete o.c. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 61 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP Deck (Note 1) Type Fasten (Note 11) Attach No. (Note 13) (Note 15) (psf) Min. 22 ga., Type B, EverGuard TPO Fleece- Grade 33 steel or min. One or more layers, any Min. 0.25-inch SECUROCK Gypsum- 1 per Back Membrane / LRF- S-362. 2,500 psi structural combination, min. 1-inch Fiber Roof Board Note 2 1.8 ft2 M or LRF-O, 12-inch -52.5 concrete O.C. Min. 22 ga., Type B, EverGuard TPO Fleece - Grade 33 steel or min. (Optional) One or more Min. 1.5-inch EnergyGuard Polyiso 1 per Back Membrane / LRF- 5-363. 2,500 psi structural layers, any combination Insulation, EnergyGuard Ultra Note 2 1.3 ft2 M or LRF-O, 12-inch -60.0 concrete O.C. Min. 22 ga., Type B, EverGuard TPO Fleece - 5-364. Grade 33 steel or min. (Optional) One or more Min. 1.5-inch EnergyGuard Polyiso Note 2 1 per Back Membrane /LRF- -67.5 2,500 psi structural layers, any combination Insulation 1.3 ft2 concrete M, 12-inch o.c. Drill-Tec #12 (steel only) or#14 with Drill-Tec 3" Standard Min. 22 ga., Type B, Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or EverGuard TPO Fleece - 5-365. Grade 33 steel or min. One or more layers, any Min. 0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per Back Membrane /LRF. -30.0* 2,500 psi structural combination, min. 1-inch SECUROCK Gypsum -Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fasteneror 4.0 ft2 concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat M or LRF-O, 4-inch o.c. Steel Plate Min. 22 ga., Type B, EverGuard TPO Fleece- S-366. Grade 33 steel or min. (Optional) One or more Min. 1.5-inch EnergyGuard RH, Note 2 1 per Membrane/ Back Membrane / LRF- / LRF- -45.0* 2,500 psi structural layers, any combination EnergyGuard RN 2.0 ft2 M or LRF-O, Min. 22 ga., Type B, EverGuard TPO Fleece - 5-367. Grade 33 steel or min. (Optional) One or more Min. 2-inch EnergyGuard RH, Note 2 1 per Back Membrane /LRF -45.0* 2,500 psi structural layers, any combination EnergyGuard RN 2.9 ft2 concrete M or LRF-O, 4-inch o.c.. Min. 22 ga., Type B, Min. 1.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- 5-368. Grade 33 steel or min. (Optional) One or more Insulation, EnergyGuard RH, Note 2 I 1 pe 2 Back Membrane / LRF- -60.0 2,500 psi structural layers, any combination ft concrete EnergyGuard RN, EnergyGuard RN M or LRF-0, 4-inch o.c. Min. 22 ga., Type B, EverGuard TPO Fleece- S-369. Grade 33 steel or min. (Optional) One or more Min. 0.25-inch DensDeck Prime Note 2 1 per Back Membrane / LRF- -45.0* 2,500 psi structural layers, any combination 2.0 ft2 concrete M or LRF-O, 4-inch o.c. Drill-Tec #12 (steel only) or#14 with Drill-Tec 3" Standard Min. 22 ga., Type B, Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or EverGuard TPO Fleece- S-370. Grade 33 steel or min. One or more layers, any Min. 0.25-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 35 or Drill- 1 per Back Membrane / LRF- -45.0* 2,500 psi structural combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fasteneror 3.2 ft2 concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat M or LRF-O, 4-inch o.c. Steel Plate NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 62 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP Deck (Note 1) Type Fasten (Note 11) Attach No. (Note 13) (Note 15) (psf) Drill-Tec #12 (steel only) or #14 with Drill-Tec 3" Standard Min. 22 ga., Type B, Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or EverGuard TPO Fleece- S-371. Grade 33 steel or min. One or more layers, any Min. 0.375-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates orwith Drill-Tec ASAP 3S or Drill- 1 per Back Membrane / LRF- -45.0* 2,500 psi structural combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fastener or 4.0 ft2 concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat M or LRF-0, 4-inch o.c. Steel Plate Min. 22 ga., Type B, EverGuard TPO Fleece- S-372. Grade 33 steel or min. One or more layers, any Min. 0.375-inch SECUROCK Gypsum- Note 2 1 per Membrane/RF- Back Membrane /LRF- -67.5 2,500 psi structural combination Fiber Roof Board 1.3 ft2 concrete M or LRF-0, EverGuard TPO Fleece -Back Membrane in Spatter Applications: EverGuard TPO Fleece - Min. 22 ga., Type B, Note 2 Back MembraneL GAF 5-373. Grade 33 steel or min. (Optional) One or more ( P ) Min. 2-inch EnergyGuard Polyiso Sy y 6 parts per min. 4 x 8 ft board with parts installed 36-inch o.c. 1 per p 2-Part (spatter), LRF-XF -30.0* 2,500 psi structural layers, any combination Insulation, EnergyGuard Ultra in two parallel rows, 12 inches from the 8 ft edges of the 5.3 ft2 board (spatter) or OB500 concrete (spatter) Drill-Tec #12 (steel only) or#14 with Drill-Tec 3" Standard EverGuard TPO Fleece - Min. 22 ga., Type B, Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or Back MembraneGAF 5-374. Grade 33 steel or min. One or more layers, any Min. 0.25-inch DensDeck Prime or Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per a(spatter), LRF-XF -30.0* 2,500 psi structural combination, min. 1-inch SECUROCK Gypsum -Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fasteneror 4.0 ft2 concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat (sp (spatter) or 06500 Steel Plate (spatter) EverGuard TPO Fleece - Min. 22 ga., Type B, Back MembraneGAF 5-375. Grade 33 steel or min. (Optional) One or more Min. 1.5-inch EnergyGuard Polyiso Note 2 1 per L Part (spatter), RF-XF -37.5* 2,500 psi structural layers, any combination Insulation, EnergyGuard Ultra 2.7 ft2 concrete (spatter) or OB500 (s (spatter) EverGuard TPO Fleece - Min. 22 ga., Type B, Min. 1.5-inch EnergyGuard Polyiso Back Membrane / GAF S-376. Grad Grade 33 steel or min. (Optional) One or more Insulation, EnergyGuard Ultra, Note 2 1 per 2-Part (spatter), LRF-XF -45.0* 2,500 psi structural layers, any combination 2 0 ft2 concrete EnergyGuard RH, EnergyGuard RN (spatter) or OB500 (spatter) Note 2 1 per EverGuard TPO Fleece - Min. 22 ga., Type B, 0 0 0 0 0 2.3 ft2 Back Membrane/ GAF 5-377. Grade 33 steel or min. (Optional) One or more Min. 2.5-inch EnergyGuard Polyiso - 14 pa(spatterLRF-XF -45.0 2,500 psi structural layers, any combination Insulation, EnergyGuard Ultra o 0 0 o parts (spatter) or OB500 (s concrete 0 0 0 0 o per4x8 (spatter) a F ftboard) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 63 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP No. Deck (Note 1) (Note 13) (Note 15) (psf) Type Fasten (Note 11) Attach EverGuard TPO Fleece - Min. 22 ga., Type B, Note 2 Back MembraneGAF 5-378. Grade 33 steel or min. (Optional) One or more Min. 2-inch EnergyGuard Polyiso 8 parts per min. 4 x 8 ft board with parts installed 24-inch o.c. 1 per (spatter), LRF-XF -45.0* 2,500 psi structural layers, any combination Insulation, EnergyGuard Ultra in two parallel rows, 12 inches from the 8 ft edges of the 4.0 ft' (spatter) (spaattter) or OB500 concrete board (spatter) EverGuard TPO Fleece - Min. 22 ga., Type B, Back MembraneGAF 5-379. Grade 33 steel or min. (Optional) One or more Min. 2-inch EnergyGuard Ultra, Note 2 1 per Part (spatter), RF-XF L -45.0* 2,500 psi structural layers, any combination EnergyGuard RH, EnergyGuard RN 2.9 ft' (spatter) or OB500 (s concrete (spatter) Min. 22 ga., Type B, Min. 1.5-inch EnergyGuard Polyiso EverGuard TPO Fleece - Back Membrane / GAF 5-380. Grade 33 steel or min. (Optional) One or more Insulation, EnergyGuard Ultra, Note 2 1 per 2-Part (spatter), LRF-XF -60.0 2,500 psi structural layers, any combination EnergyGuard RH, EnergyGuard RN, 1.3 ft2 (spatter) or OB500 concrete EnergyGuard RN (spatter) EverGuard TPO Fleece - Min. 22 ga., Type B, Back Membrane / GAF 5-381. Grade 33 steel or min. (Optional) One or more Min. 0.25-inch DensDeck Prime Note 2 1 per 2-Part (spatter), LRF-XF -45.0* 2,500 psi structural layers, any combination 2.0 ft' (spatter) or OB500 concrete (spatter) Drill-Tec #12 (steel only) or#14 with Drill-Tec 3" Standard EverGuard TPO Fleece - Min. 22 ga., Type B, Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or Back Membrane / GAF 5-382. Grade 33 steel or min. One or more layers, any Min. 0.25-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per 2-Part (spatter), LRF-XF -45.0* 2,500 psi structural combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fasteneror 3.2 ft' (spatter) or OB500 concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate (spatter) Drill-Tec #12 (steel only) or#14 with Drill-Tec 3" Standard EverGuard TPO Fleece - Min. 22 ga., Type B, Steel Plates, Drill-Tec 3 in. Ribbed Galvalume Plates (Flat) or Back Membrane / GAF 5-383. Grade 33 steel or min. One or more layers, any Min. 0.375-inch SECUROCK Gypsum- Drill-Tec AccuTrac Flat Plates or with Drill-Tec ASAP 3S or Drill- 1 per 2-Part (spatter), LRF-XF -45.0* 2,500 psi structural combination, min. 1-inch Fiber Roof Board Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fasteneror 4.0 ft' (spatter) or OB500 concrete Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate (spatter) EverGuard TPO Fleece - Min. 22 ga., Type B, Back Membrane / GAF 5-384. Grade 33 steel or min. One or more layers, any Min. 0.25-inch DensDeck Prime or Note 2 1 per 2-Part (spatter), LRF-XF -52.5 2,500 psi structural combination, min. 1-inch SECUROCK Gypsum -Fiber Roof Board 18 ft' (spatter) or OB500 concrete (spatter) EverGuard TPO Fleece - Min. 22 ga., Type B, Back Membrane / GAF 5-385. Grade 33 steel or min. One or more layers, any Min. 0.375-inch SECUROCK Gypsum- Note 2 1 per 2-Part (spatter), LRF-XF -67.5 2,500 psi structural combination Fiber Roof Board 1.3 ft' (spatter) or OB500 concrete (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMD ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 64 of 156 NNEMO I etc. TABLE 2E: STEEL OR STRUCTURAL CONCRETE •REROOF (TEAR -OFF) OR RECOVER System SYSTEM Base Insulation Layer TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF Top Insulation Layer Roof Cover MDP No. Deck (Note 1) (Note 13) Type Fasten (Note 11) Attach (Note 15) (psf) Min. 22 ga., Type B, One or more layers, min. EverGuard TPO Fleece- 5-386. Grade 33 steel or min. 1.5-inch EnergyGuard Min. 0.375-inch SECUROCK Gypsum- Note 2 1 pert Back Membrane / -82.5 psi structural Fiber Roof Board 1.45 ft concrete concrete Polyiso Insulation OB500 (spatter) TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED B System Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP Deck (Note 1) No. Layer (Note 13) Type Fasten (Note 11) Attach Base Ply Cap Ply (psf) Asphalt -Applied Base Ply: Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastenerwith Drill- EverGuard TPO Fleece -Back Min. 22 ga., Type B, (Optional) One or Min. 0.25-inch Tec 3 in. Ribbed Galvalume Plate (Flat) or Drill-Tec AccuTrac Flat Ruberoid 20 Membrane/ hot asphalt, GAF 5-387. Grade 33 steel or more layers, any SECUROCK Gypsum- Plate, Drill-Tec #12 DP Fastener (steel only), Drill-Tec #14 HD 1 per Smooth /hot 2-Part (spatter), LRF-XF -30.0* min. 2,500 psi Fastener or Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" 4.0 fti structural concrete combination Fiber Roof Board Flat Steel Plate or Drill-Tec #12 DPH Fastener (steel only) with Drill- asphalt (spatter) or OB500 (spatter) Tec 3" Recessed Steel Plate or LRF-O, 12-inch o.c. Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastenerwith Drill- EverGuard TPO Fleece -Back Min. 22 ga., Type B, (Optional) One or Min. 0.375-inch Tec 3" Standard Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate Ruberoid 20 Membrane/ hot asphalt, GAF 5-388. Grade 33 steel or more layers, any SECUROCK Gypsum- (Flat) or Drill-Tec AccuTrac Flat Plate, Drill-Tec #12 DP Fastener 1 per Smooth /hot 2-Part (spatter), LRF-XF -45.0* min. 2,500 psi (steel only), Drill-Tec#14 HD Fastener or Drill-Tec #15 EHD 4.0 ft' structural concrete combination Fiber Roof Board Fastener (steel only) with Drill-Tec 3" Flat Steel Plate or Drill-Tec asphalt (spatter) or OB500 (spatter) #12 DPH Fastener (steel only) with Drill-Tec 3" Recessed Steel Plate or LRF-O, 12-inch o.c. Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastenerwith Drill- EverGuard TPO Fleece -Back Min. 22 ga., Type B, (Optional) One or Min. 0.25-inch Tec 3" Standard Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate Ruberoid 20 Membrane/ hot asphalt, GAF 5-389. Grade 33 steel or more layers, any SECUROCK Gypsum- (Flat) or Drill-Tec AccuTrac Flat Plate, Drill-Tec #12 DP Fastener 1 per Smooth /hot 2-Part (spatter), LRF-XF -45.0* min. 2,500 psi (steel only), Drill-Tec#14 HD Fastener or Drill-Tec #15 EHD 3.2 ft' structural concrete combination Fiber Roof Board Fastener (steel only) with Drill-Tec 3" Flat Steel Plate or Drill-Tec asphalt (spatter) or OB500 (spatter) #12 DPH Fastener (steel only) with Drill-Tec 3" Recessed Steel Plate or LRF-O, 12-inch o.c. Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastenerwith Drill- EverGuard TPO Fleece -Back Min. 22 ga., Type B, (Optional)One or Min. 0.25-inch Tec 3" Standard Steel Plate or Drill-Tec AccuTrac Flat Plate, Drill- Ruberoid 20 Membrane/ hot asphalt, GAF 5-390. Grade 33 steel or more layers, any SECUROCK Gypsum- Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fastener or Drill- 1 per Smooth /hot 2-Part (spatter), LRF-XF -52.5 min. 2,500 psi Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Fla[ Steel Plate 1.6 ft2 structural concrete combination Fiber Roof Board or Drill-Tec #12 DPH Fastener (steel only) with Drill-Tec 3" asphalt (spatter) or OB500 (spatter) Recessed Steel Plate or LRF-0, 12-inch o.c. Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastenerwith Drill- EverGuard TPO Fleece -Back Min. 22 ga., Type B, (Optional) One or Min. 0.375-inch Tec 3" Standard Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate Ruberoid 20 Membrane/ hot asphalt, GAF 5-391. Grade 33 steel or more layers, any SECUROCK Gypsum- (Flat) or Drill-Tec AccuTrac Flat Plate, Drill-Tec #12 DP Fastener 1 per Smooth /hot 2-Part (spatter), LRF-XF -60.0 min. 2,500 psi (steel only), Drill-Tec #14 HD Fastener or Drill-Tec #15 EHD 1.3 fti structural concrete combination Fiber Roof Board Fastener (steel only) with Drill-Tec 3" Flat Steel Plate or Drill-Tec asphalt (spatter) or OB500 (spatter) #12 DPH Fastener (steel only) with Drill-Tec 3" Recessed Steel Plate or LRF-O, 12-inch o.c. Torch -Applied Base Ply: NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 7'^ Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 65 of 156 NNEMO I etc. OF: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System ATTACHEDSYSTEM TYPE C-1: MECHANICALLY INSULATION, BONDED BASE Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP Deck (Note 1) Layer (Note 13) Type Fasten (Note 11) Attach Base Ply Cap Ply No. (psf) Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastenerwith Drill- EverGuard TPO Fleece -Back Min. 22 ga., Type B, (Optional) One or Min. 0.25-inch Tec 3 in. Ribbed Galvalume Plate (Flat) or Drill-Tec AccuTrac Flat Ruberoid HW Membrane /hot asphalt, GAF 5-392. Grade 33 steel or more layers, any SECUROCK Gypsum- Plate, Drill-Tec #12 DP Fastener (steel only), Drill-Tec #14 HD 1 per 25 Smooth / 2-Part (spatter), LRF-XF -30.0* min. 2,500 psi Fastener or Drill-Tec #15 EHD Fastener (steel only) with Drill-Tec 3" 4.0 fti structural concrete combination Fiber Roof Board Flat Steel Plate or Drill-Tec #12 DPH Fastener (steel only) with Drill- torch -applied (spatter) or OB500 (spatter) Tec 3" Recessed Steel Plate Or LRF-0, 12-inch O.C. Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastenerwith Drill- EverGuard TPO Fleece -Back Min. 22 ga., Type B, (Optional) One or Min. 0.375-inch Tec 3" Standard Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate Ruberoid HW Membrane /hot asphalt, GAF 5-393. Grade 33 steel or more layers, any SECUROCK Gypsum- (Flat) or Drill-Tec AccuTrac Flat Plate, Drill-Tec #12 DP Fastener 1 per 25 Smooth / 2-Part (spatter), LRF-XF -45.0* min. 2,500 psi (steel only), Drill-Tec#14 HD Fastener or Drill-Tec #15 EHD 4.0 fti structural concrete combination Fiber Roof Board Fastener (steel only) with Drill-Tec 3" Flat Steel Plate or Drill-Tec torch -applied (spatter) or OB500 (spatter) #12 DPH Fastener (steel only) with Drill-Tec 3" Recessed Steel Plate Or LRF-O, 12-inch o.c. Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastener with Drill- EverGuard TPO Fleece -Back Min. 22 ga., Type B, (Optional) One or Min. 0.25-inch Tec 3" Standard Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate Ruberoid HW Membrane/ hot asphalt, GAF 5-394. Grade 33 Steel or more layers, any SECUROCK Gypsum- (Flat) or Drill-Tec AccuTrac Flat Plate, Drill-Tec #12 DP Fastener 1 per 25 Smooth / 2-Part (spatter), LRF-XF -45.0* min. 2,500 psi (steel only), Drill-Tec#14 HD Fastener or Drill-Tec #IS EHD 3.2 fti structural concrete combination Fiber Roof Board Fastener (steel only) with Drill-Tec 3" Flat Steel Plate or Drill-Tec torch_ applied (spatter) Or OBS00 (spatter) #12 DPH Fastener (steel only) with Drill-Tec 3" Recessed Steel Plate or LRF-O, 12-inch o.c. Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastenerwith Drill- EverGuard TPO Fleece -Back Min. 22 ga., Type B, (Optional)One or Min. 015-inch Tec 3" Standard Steel Plate or Drill-Tec AccuTrac Flat Plate, Dr- ill Ruberoid HW Membrane/ hot asphalt, GAF 5-395. Grade 33 steel or more layers, any SECUROCK Gypsum- Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fastener or Drill- 1 per 25 Smooth / 2-Part (spatter), LRF-XF -52.5 min. 2,500 psi Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Fla[ Steel Plate 1.6 fti structural concrete combination Fiber Roof Board or Drill-Tec #12 DPH Fastener (steel only) with Drill-Tec 3" torch -applied (spatter) Or OB500 (spatter) Recessed Steel Plate or LRF-O, 12-inch o.c. One or more Min. 0.25-inch Ruberoid HW EverGuard TPO Fleece -Back Min. 22 ga., type B, 25 Smooth, Membrane / hot asphalt, GAF S-396. Grade 40 steel or layers, any DensDeck Prime or Note 2 1 per Ruberoid HW 2-Part (spatter), LRF-XF -60.0 structural concrete combination, SECUROCK Gypsum- 1.45 ft2 Smooth / torch- (spatter) or OB500 (spatter) loose laid Fiber Roof Board applied or LRF-O, 12-inch o.c. Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastenerwith Drill- EverGuard TPO Fleece -Back Min. 22 ga., Type B, (Optional) One or Min. 0.375-inch Tec 3" Standard Steel Plate, Drill-Tec 3 in. Ribbed Galvalumeate Plate Ruberoid HW Membrane/ hot asphalt, GAF 5-397. Grade 33 Steel or more layers, any SECUROCK Gypsum- (Flat) or Drill-Tec AccuTrac Flat Plate, Drill-Tec #12 DP Fastener 1 per 25 Smooth / 2-Part (spatter), LRF-XF -60.0 min. 2,500 psi (steel only), Drill-Tec#14 HD Fastener or Drill-Tec #IS EHD 1.3 fti structural concrete combination Fiber Roof Board Fastener (steel only) with Drill-Tec 3" Flat Steel Plate or Drill-Tec torch -applied (spatter) or OB500 (spatter) #12 DPH Fastener (steel only) with Drill-Tec 3" Recessed Steel Plate or LRF-O, 12-inch o.c. Self -Adhering Base Ply: Min. 22 ga., Type B, Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastenerwith Drill- Liberty Self - EverGuard TPO Fleece -Back Grade 33 steel or (Optional) One or Min. 0.25-inch Tec 3 in. Ribbed Galvalume Plate (Flat) or Drill-Tec AccuTrac Flat 1 per Adhering Cap g C Membrane/ hot asphalt, GAF S-398. min. psi more layers, an Y Y SECUROCK Gypsum- Yp Plate or Drill-Tec #12 DP Fastener steel only), Drill-Tec #14 HD ( v), 4.0 ft� Sheet / self - 2-Part(spatter), LRF-XF -30.0* combination Fiber Roof Board Fastener or Drill-Tec#15 EHD Fastener (steel only) with Drill-Tec 3" (spatter) or OB500 (spatter) structural concrete structural Flat Steel Plate adhered or LRF-0, 12-inch o.c. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'^ Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 66 of 156 NNEMO I etc. OF: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System ATTACHEDSYSTEM TYPE C-1: MECHANICALLY INSULATION,BONDED BASE Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP Deck (Note 1) Layer (Note 13) Type Fasten (Note 11) Attach Base Ply Cap Ply No. (psf) Min. 22 ga., Type B, Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastener with Drill- Liberty SBS Self- EverGuard TPO Fleece -Back Grade 33 steel or (Optional) One or Min. 0.375-inch Tec 3" Standard Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate 1 per A dhering Cap Membrane / hot asphalt, GAF 5-399. more layers, any SECUROCK Gypsum- (Flat) or Drill-Tec AccuTrac Flat Plate or Drill-Tec #12 DP Fastener 2-Part (spatter), LRF-XF -45.0* min. 2,500 psi combination Fiber Roof Board (steel only), Drill-Tec#14 HD Fastener or Drill-Tec #IS EHD . 40 ft2 Sheet / self - (spatter) or OB500 (spatter) structural concrete Fastener (steel only) with Drill-Tec 3" Flat Steel Plate adhered or LRF-0, 12-inch o.c. Min. 22 ga., Type B, Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastener with Drill- Liberty SBS Self- EverGuard TPO Fleece -Back Grade 33 steel or (Optional) One or Min. 0.25-inch Tec 3" Standard Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate Adhering Cap Membrane / hot asphalt, GAF 5-400. more layers, any SECUROCK Gypsum- (Flat) or Drill-TecAccuTrac Flat Plate or Drill-Tec #12 DP Fastener 2-Part (spatter), LRF-XF -45.0* min. 2,500 psi combination Fiber Roof Board Drill-Tec H Fastener or Drill-Tec EHD ( steel only), D .per 3.2 ft� Sheet / self - (spatter) (spatter) structural concrete r to Fastener (steel only) with Drill-Tec 3" Flat Steel Plate (steel l with adhered 1 -inch or LRF-0, 12-inch o.c. EverGuard TPO Fleece -Back Min. 22 a., Type B, g YP (Optional) One or Min. 0.25-inch Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastener with Drill- Liberty SBS Self- Y Membrane / hot asphalt, GAF 5-401. Grade 33 Steel or more layers, any SECUROCK Gypsum- Tec 3" Standard Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill- 1 per Adhering Cap 2-Part (spatter), LRF-XF -52.5 min. 2,500 psi Tec #12 DP Fastener (steel only), Drill-Tec #14 HD Fastener or Drill- 1.6 ft z Sheet / self - structural concrete combination Fiber Roof Board Tec #15 EHD Fastener (steel only) with Drill-Tec 3" Flat Steel Plate adhered (spatter) or OB500 (spatter) or LRF-0, 12-inch o.c. Min. 22 ga., Type B, Drill-Tec #12 Fastener (steel only), Drill-Tec #14 Fastener with Drill- Liberty SBS Self- EverGuard TPO Fleece -Back Grade 33 steel or (Optional) One or Min. 0.375-inch Tec 3" Standard Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate 1 per Adhering Cap Membrane / hot asphalt, GAF 5-402. min. 2,500 psi more layers, any SECUROCK Gypsum- (Flat) or Drill-TecAccuTrac Flat Plate or Drill-Tec #12 DP Fastener 1.3 ft� Sheet / self- 2-Part (spatter), LRF-XF -60.0 Combination Fiber Roof Board (steel only), Drill-Tec #14 HD Fastener or Drill-Tec #15 EHD (spatter) or OB500 (spatter) structural concrete Fastener (steel only) with Drill-Tec 3" Flat Steel Plate adhered or LRF-0, 12-inch o.c. CONCRETETABLE 2G: STEEL OR STRUCTURAL .ECKS - NEW CONSTRUCTION, REROO•RECOVER VAPORSYSTEM TYPE C-1A: THERMAL BARRIER WITH • INSULATION,BONDED ROOCOVER System Top Insulation Layer Roof Cover MDP Deck (Note 1) Thermal Barrier/ Vapor Barrier No. Type Fasten (Note 11) Attach (Note 15) (psf) EverGuard Freedom TPO: Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch EverGuard 5-403. Grade 33 steel or SoGypsum-Fiber Roof Board, loose -laid, Min. 1.5-inch EnergyGuard Polyiso Insulation, Note 2 (no 1 per Freedom TPO / -45.0* min. 2,500 psi covered th GAF SA Vapor Retarder, self -adhered covered with EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN recessed plate) 2.0 ft2 self adhered structural concrete Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch EverGuard 5-404. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, Min. 2-inch EnergyGuard RA, EnergyGuard RN Note 2 (no 1 per Freedom TPO / -45.0* min. 2,500 psi covered with GAF SA Vapor Retarder, self -adhered recessed plate) 4.0 ft� self adhered l structuraconcrete Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard 5-405. Grade 33 steel or S Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 (no 1 per Freedom TPO / -45.0* min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.25-inch recessed plate) 2.0 ft� structural concrete cooveredvered with GAF SA Vapor Retarder, self -adhered SECUROCK Gypsum -Fiber Roof Board self adhered NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 67 of 156 NNEMOjetc. TABLE 2G: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM TYPE C-IA: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Top Insulation Layer Roof Cover MDP No Deck (Note 1) Thermal Barrier / Vapor Barrier (Note 15) (psf) Type Fasten (Note 11) Attach Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard RH, loose laid, followed by EverGuard 5-406. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, Note 2 (no 1 per Freedom TPO / -45.0* min. 2,500 psi EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus recessed plate) 2.0 ft a structural concrete covered with GAF SA Vapor Retarder, self -adhered Polyiso Insulation self adhered Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch EverGuard 5-407. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, Min. 2-inch EnergyGuard RA, EnergyGuard RN Note 2 (#14) (no 1 per Freedom TPO / -52.5 min. 2,500 psi recessed plate) 2.0 ft2 structural concrete covered with GAF SA Vapor Retarder, self -adhered self adhered EverGuard TPO / EverGuard TPO #1122. Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / 5-408. Grade steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 #1121, TPO 3- -45.0* min. 5 psi .per 2.0 ft2 structturalural concrete covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RH Square Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch EverGuard TPO / 5-409. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, Min. 2-inch EnergyGuard RA, EnergyGuard RN, Note 2 1 per #1121, TPO 3- -45.0* min. 2,500 psi covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RH 4.0 ft' Square structural concrete Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch , Min. 1.5-inch EnergyGuard Polyiso Insulation EverGuard TPO / 5-410. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per #1121, TPO 3- -45.0* min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.25-inch 2.0 ft2Square structural concrete covered with GAF SA Vapor Retarder, self -adhered DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch . Min1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / 5-411. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per #1121, TPO 3- -45.0* min. 2,500 psi covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RH, loose laid, followed by min. 0.5-inch 3.2 ft2 Square structural concrete DensDeck Prime Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch . Min1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / 5-412. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per #1121, TPO 3- -45.0* min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.625-inch 4.0 ft a structural concrete covered with GAF SA Vapor Retarder, self -adhered DensDeck Prime Square Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard RH, loose laid, followed by EverGuard TPO / 5-413. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, Note 2 1 per #1121, TPO 3- -45.0* min. psi EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus 2.0 ft2 structural structural concrete covered with GAF SA Vapor Retarder, self -adhered Polyiso Insulation Square Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / F Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per #1121, TPO 3- -52.5 min. 2,500 psi covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RH, loose laid, followed by min. 0.25-inch 1.45 ft2 Square structural concrete DensDeck Prime NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 68 of 156 NNEMOjetc. TABLE 2G: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE C-IA: THERMAL BARRIER WITH VAPOR System BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Top Insulation Layer Roof Cover MDP No Deck (Note 1) Thermal Barrier / Vapor Barrier Type Fasten (Note 11) Attach (Note 15) (psf) Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch . Min. 15-inch EnergyGuard Polyiso Insulation, EverGuard TPO / Grade 33 steel or 5-415. SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per #1121, TPO 3- -52.5 min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.25-inch 1.6 ft a covered with GAF SA Vapor Retarder, self -adhered structural concrete SECUROCK Gypsum -Fiber Roof Board Square EverGuard TPO / EverGuard WB381 Bonding Adhesive: Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, 5-416. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per EverGuard TPO / -45.0* min. 2,500 psi covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RH 2.0 ft2 WB181 structural concrete Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch 5-417. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, Min. 2-inch EnergyGuard RA, EnergyGuard RN, Note 2 1 per EverGuard TPO / -45.0* min. 2,500 psi EnergyGuard RH 4.0 ft2 WB181 structural concrete covered with GAF SA Vapor Retarder, self -adhered Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, 5-418. Grade 33 steel or Gypsum -Fiber Roof Board, loose -laid, covered EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per EverGuard TPO / -45.0* min. 2,500 psi i Covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RH, loose laid, followed by min. 0.25-inch 2.0 ft' WB181 structural concrete DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board Min. 22 ga., Type B, Min. inch DensDeck Prime or min. Min. 1.5-inch EnergyGuard Polyiso Insulation, Grade 33 steel or EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, 1 per EverGuard TPO / 5-419. min. psi ROCK se -finch SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard RH, loose laid, followed by min. 0.5-inch Note 2 : 3.2 ft2 W8181 -45.0* structural concrete structural covered with GAF SA Vapor Retarder, self -adhered DensDeck Prime Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, 5-420. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per EverGuard TPO / -45.0* min. 2,500 psi covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RH, loose laid, followed by min. 0.625-inch 4.0 ft2 WB181 structural concrete DensDeck Prime Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard RH, loose laid, followed by 5-421. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, Note 2 1 per EverGuard TPO / -45.0* min. 2,500 psi EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus 2.0 ft a WB181 structural concrete covered with GAF SA Vapor Retarder, self -adhered Polyiso Insulation Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, Grade 33 steel or EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, 1 per EverGuard TPO / 5-422. min. psi SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard RH, loose laid, followed by min. 0.25-inch Note 2 1.45 ft2 WB181 -52.5 structturalural concrete covered with GAF SA Vapor Retarder, self -adhered DensDeck Prime Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, 5-423. Grade 33 steel or Gypsum -Fiber Roof Board, loose -laid, covered EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per EverGuard TPO / -52.5 min. 2,500 psi covered with GAF SA Vapor Retarder, self -adhered i EnergyGuard RH, loose laid, followed by min. 0.25-inch 1.6 ft2 WB181 structural concrete SECUROCK Gypsum -Fiber Roof Board EverGuard TPO / EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMo ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 69 of 156 NNEMOjetc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM TYPE C-IA: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Top Insulation Layer Roof Cover MDP No Deck (Note 1) Thermal Barrier / Vapor Barrier (Note 15) (psf) Type Fasten (Note 11) Attach Min. 22 ga., Type B, Grade 33 steel or Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, 1 per EverGuard TPO / S 424 min. 2,500 psi SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 2.0 ft' TPO 6-Square, -45.0* structural concrete covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RH TPO 3-Square Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch EverGuard TPO / 5-425. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, Min. 2-inch EnergyGuard RA, EnergyGuard RN, Note 2 1 per TPO 6-Square, -45.0* min. 2,500 psi EnergyGuard RH 4.0 ft i structural concrete covered with GAF SA Vapor Retarder, self -adhered TPO 3-Square Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch . Min1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / 5-426. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per TPO 6-Square, -45.0* min. psi covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RH, loose laid, followed inch 2.0 ft� TPO 3-Square structural structural concrete -min. Roof DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch , Min. 1.5-inch EnergyGuard Polyiso Insulation EverGuard TPO / 5-427. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 pe TPO 6-Square, -45.0* min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.5-inch 3.2 ft2 structural concrete covered with GAF SA Vapor Retarder, self -adhered DensDeck Prime TPO 3-Square Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch . Min1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / 5-428. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per TPO 6-Square, -45.0* min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.625-inch 4.0 ft2 structural concrete covered with GAF SA Vapor Retarder, self -adhered DensDeck Prime TPO 3-Square Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard RH, loose laid, followed by EverGuard TPO / S 429. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, Note 2 1 per TPO 6-Square, -45.0* min. 2,500 psi EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus 2 0 ft2 structural concrete covered with GAF SA Vapor Retarder, self -adhered Polyiso Insulation TPO 3-Square Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch , Min. 1.5-inch EnergyGuard Polyiso Insulation EverGuard TPO / 5-430. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per TPO 6-Square, -52.5 min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.25-inch 1.45 ft2 structural concrete covered with GAF SA Vapor Retarder, self -adhered DensDeck Prime TPO 3-Square Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch . Min1.5-inch EnergyGuard Polyiso Insulation, EverGuard / 5-431. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per re, TPO 6-Square, -52.5 min. psi covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RH, loose laid, followed by min. 0.25-inch 1.6 ft2 TPO 3-Square structturalural concrete SECUROCK Gypsum -Fiber Roof Board EverGuard TPO / FASTLAYN TPO ADHESIVE: Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch EverGuard TPO / 5-432. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, Min. 1.5-inch EnergyGuard Polyiso Insulation, Note 2 1 per FastLayn TPO -45.0* min. psi covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RA 2.0 ft' Adhesive structuraltural concrete NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMo ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 70 of 156 NNEMOjetc. TABLE 2G: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System SYSTEM TYPE C-IA: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Top Insulation Layer Roof Cover MDP No Deck (Note 1) Thermal Barrier / Vapor Barrier (Note 15) (psf) Type Fasten (Note 11) Attach Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch EverGuard TPO / 5-433. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, Min. 2-inch EnergyGuard RA Note 2 1 pea FastLayn TPO -45.0* min. 2,500 psi covered with GAF SA Vapor Retarder, self -adhered 4.0 ft Adhesive structural concrete Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch , Min. 1.5-inch EnergyGuard Polyiso Insulation EverGuard TPO / 5-434. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per FastLayn TPO -45.0* min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.25-inch 2.0 ft2 structural concrete covered with GAF SA Vapor Retarder, self -adhered DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board Adhesive Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch . Min1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / 5-435. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per FastLayn TPO -45.0* min. 2,500 psi covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RH, loose laid, followed by min. 0.5-inch 3.2 ft� Adhesive structural concrete DensDeck Prime Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation , EverGuard TPO / 5-436. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per FastLayn TPO -45.0* min. psi EnergyGuard RH, loose laid, followed by min. 0.625-inch 4.0 ft2 structuraltural concrete covered with GAF SA Vapor Retarderself-adhered , DensDeck Prime Adhesive Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch EverGuard TPO / 5-437. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, Min. 1.5-inch EnergyGuard RH, loose laid, followed by Note 2 1 per FastLayn TPO -45.0* min. 2,500 psi covered with GAF SA Vapor Retarder, self -adhered min. 0.5-inch EnergyGuard HD Polyiso Insulation 2.0 ft2 Adhesive structural concrete Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch . Min1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / 5-438. Grade 33 steel or SoGypsum-Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per FastLayn TPO -52.5 min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.25-inch 1.45 ft2 structural concrete covered vered with GAF SA Vapor Retarder, self -adhered DensDeck Prime Adhesive Min. 22 ga., Type B, Min. 0.625-inch DensDeck Prime or min. 0.5-inch , Min. 1.5-inch EnergyGuard Polyiso Insulation EverGuard TPO / 5-439. Grade 33 steel or SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per FastLayn TPO -52.5 min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.25-inch 1.6 ft2 structural concrete covered with GAF SA Vapor Retarder, self -adhered SECUROCK Gypsum -Fiber Roof Board Adhesive EverGuard TPO Fleece -Back Membrane in EverGuard WB381 Bonding Adhesive: Min. 22 ga., Type Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO 5-440. B, Grade,steel SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 pe Fleece -Back -45.0* r min. 2,5 psi covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RH 2.. 0 ft2 Membrane / s500 structural concrete W B181 Min. 22 ga., Type Min. inch DensDeck Prime or min. EverGuard TPO 5-441. B, Grade 33 steel SECUROCK se -finch ROCK Gypsum -Fiber Roof Board, loose -laid, Min. 2-inch EnergyGuard RA, EnergyGuard RN, Note 2 1 per Fleece -Back -45.0* or min. 2,500 psi EnergyGuard RH 4.0 W Membrane / structural concrete covered with GAF SA Vapor Retarder, self -adhered i WB181 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 71 of 156 NNEMOjetc. TABLE 2G: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System VAPORSYSTEM TYPE C-IA: THERMAL BARRIER WITH BARRIER, MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER Top Insulation Layer Roof Cover MDP No Deck (Note 1) Thermal Barrier / Vapor Barrier (Note 15) IPAMin. Type Fasten (Note 11) Attach 22 ga., Type Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO 5-442. B, Grade 33 steel SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per Fleece -Back -45.0* or min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.25-inch 2.0 ft 2 Membrane / structural concrete covered with GAF SA Vapor Retarder, self -adhered DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board WB181 Min. 22 ga., Type Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO 5-443. B, Grade 33 steel SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per Fleece -Back -45.0* or min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.5-inch 3.2 ft2 Membrane / structural concrete covered with GAF SA Vapor Retarder, self -adhered DensDeck Prime WB181 Min. 22 ga., Type Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO S 444 B, Grade 33 steel SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per Fleece -Back -45.0* or min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.625-inch 4.0 ft2 Membrane / structural concrete covered with GAF SA Vapor Retarder, self -adhered DensDeck Prime WB181 Min. 22 ga., Type Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO 5-445. B, Grade 33 steel SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per Fleece-Back -52.5 or min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.25-inch 1.45 ft2 Membrane / structural concrete covered with GAF SA Vapor Retarder, self -adhered DensDeck Prime WB181 Min. 22 ga., Type Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO 5-446. B, Grade 33 steel SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per Fleece -Back -52.5 or min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.25-inch 1.6 ft2 Membrane / structural concrete covered with GAF SA Vapor Retarder, self -adhered SECUROCK Gypsum -Fiber Roof Board WB181 EverGuard TPO Fleece -Back Membrane in LRF Adhesive M or LRF Adhesive O: Min. 22 ga., Type EverGuard TPO B, Grade 33 steel Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, 1 per Fleece -Back 5-447. SECUROCK Gypsum -Fiber Roof Board, loose -laid, Note 2 Membrane/ URF- -45.0* or min. 2,500 psi covered with GAF SA Vapor Retarder, self -adhered EnergyGuard RH 2.9 ft' M or LRF-O, 12- structural concrete inch o.c. Min. 22 ga., Type Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO 5-448. B, Grade 33 steel SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per Fleece -Back -45.0* or min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.25-inch 2.0 ft2Membrane / LRF- structural concrete i covered with GAF SA Vapor Retarder, self -adhered DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board 0, 12-inch o.c. Min. 22 ga., Type Min. 0.625-inch DensDeck Prime or min. 0.5-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO S 449 B, Grade 33 steel SECUROCK Gypsum -Fiber Roof Board, loose -laid, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RN, Note 2 1 per Fleece -Back -45.0* or min. 2,500 psi EnergyGuard RH, loose laid, followed by min. 0.25-inch 2.0 ft2 Membrane / LRF- structural concrete covered with GAF SA Vapor Retarder, self -adhered SECUROCK Gypsum -Fiber Roof Board M, 12-inch o.c. EverGuard TPO Min. 22 ga., Type Min. 0.625-inch DensDeck Prime or min. 0.5-inch Fleece -Back 5-450. B, Grade 33 steel SECUROCK Gypsum -Fiber Roof Board, loose -laid, Min. 1.5-inch EnergyGuard Polyiso Insulation, Note 2 1 per Membrane / LRF- -60.0 or min. 2,500 psi covered with GAF SA Vapor Retarder, self -adhered EnergyGuard Ultra 1.3 ft2 M or LRF-0, 12- structural concrete inch o.c. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMo ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 72 of 156 NNEMO I etc. TABLE 2H: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE -BONDED ROOF Insulation (Note 13) Attachment COVER Roof Cover (Note 1513) MDP No. (Note 1) Fasteners (Note 11) Density (psf) One or more layers, any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO Min. 22 ga., combination, preliminarily RhinoBond TPO XHD Plates XHD Plates or Drill-Tec RhinoBond TPO XHD Tread 5-451. type B, Grade attached (Tread Safe = min. or Drill-Tec RhinoBond TPO Max. 18-inch o.c. in rows spaced max. 60-inch o.c. Safe Plates with RhinoBond Portable Bonding Tool, -30.0 33 steel 2-inch thick insulation) XHD Tread Safe Plates per manufacturer's published instructions. Min. 22 ga., One or more layers, any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-452. type B, Grade combination, preliminarily RhinoBond TPO XHD Plates Max. 12-inch o.c. in rows spaced max. 60-inch o.c. XHD Plates orDrill-Tec RhinoBond TPO XHD Tread -37.5 attached (Tread Safe = min. or Drill-Tec RhinoBond TPO Safe Plates with RhinoBond Portable Bonding Tool, 33 steel 2-inch thick insulation) XHD Tread Safe Plates per manufacturers published instructions. One or more layers, any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-453. Min. 22 ga., type B, Grade combination, preliminarily RhinoBond TPO XHD Plates Max. 18-inch o.c. in rows spaced max. 60-inch o.c. XHD Plates or Drill-Tec RhinoBond TPO XHD Tread -37.5 80 steel attached (Tread Safe = min. or Drill-Tec RhinoBond TPO Safe Plates with RhinoBond Portable Bonding Tool, 2-inch thick insulation) XHD Tread Safe Plates per manufacturers published instructions. 1 per 5.3 ftz (6 parts per 4 x 8 ft board) One or more layers, any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO Min. 22 ga., combination, 4 x 8 ft board; RhinoBond TPO XHD Plates Fasteners located in each of the four corners of the XHD Plates or DrRhin c RhinoBond XHD Tread 5-454. type B, Grade (Tread Safe = min. 2-inch or Drill-Tec RhinoBond TPO board and at mid -span of the 96-inch length. le B Safe Plates with RhinoBond Portable Bonding Tool, _37.5 33 steel thick insulation) XHD Tread Safe Plates Fasteners are 12-inches from the board's long edges per manufacturers published instructions. and 12- and 48-inches from the board's short edges. One or more layers, any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO Min. 22 ga., combination, preliminarily RhinoBond TPO XHD Plates XHD Plates or Drill-Tec RhinoBond TPO XHD Tread 5-455. type B, Grade attached (Tread Safe = min. or Drill-Tec RhinoBond TPO Max. 12-inch o.c. in rows spaced max. 60-inch o.c. Safe Plates with RhinoBond Portable Bonding Tool, _45.0 80 steel 2-inch thick insulation) XHD Tread Safe Plates per manufacturers published instructions. 1 per 5.3 ftz (6 parts per 4 x 8 ft board) Min. 22 ga., One or more layers, any Drill-Tec XHD and Drill-Tec Fasteners located in each of the four corners of the EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-456. type B, Grade combination, 4 x 8 ft board; RhinoBond TPO XHD Plates board and at mid -span of the 96-inch length. XHD Plates or DrRhin c RhinoBond XHD Tread -45.0* (Tread Safe = min. 2-inch or Drill-Tec RhinoBond TPO Safe Plates with RhinoBond Portable Bonding Tool, le B 33 steel thick insulation) XHD Tread Safe Plates Fasteners are 6-inches from the board's long edges per manufacturers published instructions. and 12- and 48-inches from the board's short edges. 1 per 5.3 ftz (6 parts per 4 x 8 ft board) Min. 2,500 psi One or more layersany , Drill-Tec ri14 and Drill-Tec Fasteners located in each of the four corners of the EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-457. structural board and at mid -span of the 96-inch length. XHD Plates with RhinoBond Portable Bonding Tool, -45.0 concrete combination, 4 x 8 ft board RhinoBond TPO XHD Plates Fasteners are 6-inches from the board's long edges per manufacturers published instructions. and 12- and 48-inches from the board's short edges. Min. 22 ga., One or more layers, any Drill-Tec XHD and Drill-Tec 1 per 4.0 ft2 (4 parts per 4 x 4 ft board) EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-458. type B, Grade combination, 4 x 4 ft board; RhinoBond TPO XHD Plates Fasteners located in each of the four corners of the XHD Plates or DrRhin c RhinoBond XHD Tread _q5.0* 33 steel (Tread Safe = min. 2-inch or Dri RhinoBond TPO board. Fasteners are 12-inch from the board edges. le B Safe Plates with Portable Bonding Tool, thick insulation) XHD Tread Safe Plates read Safe is published per manufacturers published instructions. Min. 2,500 psi 1 per 4.0 ft' (4 parts per 4 x 4 ft board) EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-459. structural One or more layers, any Drill-Tec ri14 and Drill-Tec Fasteners located in each of the four corners of the XHD Plates with RhinoBond Portable Bonding Tool, -45.0* concrete combination, 4 x 4 ft board RhinoBond TPO XHD Plates board. Fasteners are 12-inch from the board edges. per manufacturers published instructions. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 73 of 156 NNEMO I etc. TABLE 2H: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE -BONDED ROOF Insulation (Note 13) Attachment COVER Roof Cover (Note 1513) MDP No. (Note 1) Fasteners (Note 11) Density (psf) Min. 22 ga., One or more layers, any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-460. type B, Grade combination (Tread Safe = RhinoBond TPO XHD Plates Max. 24-inch o.c. in rows spaced max. 30-inch o.c. XHD Plates or Drill-Tec RhinoBond TPO XHD Tread -52.5 33 steel min. 2-inch thick insulation) or Drill-Tec RhinoBond TPO Safe Plates with RhinoBond Portable Bonding Tool, XHD Tread Safe Plates per manufacturer's published instructions. 1 per 4.0 ftz (8 parts per 4 x 8 ft board) 9 Min. 22 One or more layers, any Drill-Tec XHD and Drill-Tec �"— EverGuard TPO bonded to Drill-Tec RhinoBond TPO ga., combination, 4 x 8 ft board; RhinoBond TPO XHD Plates o 5 XHD Plates or Drill-Tec RhinoBond TPO XHD Tread 5-461. type B, Grade (Tread Safe = min. 2-inch or Drill-Tec RhinoBond TPO x ® ♦ :, Safe Plates with RhinoBond Portable Bonding Tool, -60.0 33 steel thick insulation) XHD Tread Safe Plates ® 1 per manufacturer's published instructions. i I i Min. 22 ga., One or more layers, any Drill-Tec SXHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-462. type B, Grade combination RhinoBond TPO SXHD Plates 24 x 24 inch grid SXHD Plates with RhinoBond Portable Bonding Tool, -60.0 33 steel per manufacturers published instructions. Min. 2,500 psi One or more layers, any Drill-Tec #14 and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-463. structural 24 x 24 inch grid XHD Plates with RhinoBond Portable Bonding Tool, -60.0 concrete combination RhinoBond TPO XHD Plates per manufacturers published instructions. One or more layers, any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO Min. 22 ga., combination, preliminarily RhinoBond TPO XHD Plates XHD Plates or Drill-Tec RhinoBond TPO XHD Tread 5-464. type B, Grade attached (Tread Safe = min. or Drill-Tec RhinoBond TPO Max. 6-inch o.c. in rows spaced max. 72-inch o.c. Safe Plates with RhinoBond Portable Bonding Tool, -67.5 33 steel 2-inch thick insulation) XHD Tread Safe Plates per manufacturers published instructions. Min. 22 ga., One or more layers, any Drill-Tec XHD and Drill-Tec 1 per 2.7 ft' (12 parts per 4 x 8 ft board) EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-465. type B, Grade combination (Tread Safe = RhinoBond TPO XHD Plates Fasteners are 6-, 24- and 42-inches from the board's XHD Plates or Drill-Tec RhinoBond TPO XHD Tread -67.5 33 steel min. 2-inch thick insulation) or Drill-Tec RhinoBond TPO long edge and 12-, 36-, 60-and 84-inches from the Safe Plates with RhinoBond Portable Bonding Tool, XHD Tread Safe Plates board's short edge. per manufacturers published instructions. 18 x 24 inch staggered grid Min. 22 ga., One or more layers, any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-466. type B, Grade combination, (Tread Safe = RhinoBond TPO XHD Plates or Drill-Tec RhinoBond TPO - ® XHD Plates or Drill-Tec RhinoBond TPO XHD Tread Safe Plates with RhinoBond Portable Bonding Tool, 82 5 40 steel min. 2-inch) XHD Tread Safe Plates ® ® per manufacturers published instructions. 0ma NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 74 of 156 NNEMO I etc. TABLE 2H: STEEL OR STRUCTURAL CONCRETE •REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE -BONDED ROOF Insulation (Note 13) Attachment COVER Roof Cover (Note 1513) MDP No. (Note 1) Fasteners (Note 11) Density (psf) 1 per 2.7 ft' (12 parts per 4 x 8 ft board) o -f Min. 22 ga., One or more layers, any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO 5-467. type B, Grade combination, (Tread Safe = RhinoBond TPO XHD Plates o ® a ''. i XHD Plates or Drill-Tec RhinoBond TPO XHD Tread -82.5 40 steel min. 2-inch) or Drill-Tec RhinoBond TPO r� Safe Plates with RhinoBond Portable Bonding Tool, XHD Tread Safe Plates 0 0 0 0 per manufacturer's published instructions. Q One or more layers, any Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO Min. 22 ga., combination, preliminarily RhinoBond TPO XHD Plates XHD Plates or Drill-Tec RhinoBond TPO XHD Tread 5-468. type B, Grade attached (Tread Safe = min. or Drill-Tec RhinoBond TPO Max. 6-inch o.c. in rows spaced max. 72-inch o.c. Safe Plates with RhinoBond Portable Bonding Tool, 97.5 80 steel 2-inch thick insulation) XHD Tread Safe Plates per manufacturer's published instructions. Drill-Tec XHD and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO Min. 22 ga., One or more layers, any RhinoBond TPO XHD Plates XHD Plates or Drill-Tec RhinoBond TPO XHD Tread 5-469. type B, Grade combination, min. 2-inch or Drill-Tec RhinoBond TPO 18 x 16 inch grid, staggered 6-inch Safe Plates with RhinoBond Portable Bonding Tool, -105.0 60 steel XHD Tread Safe Plates I per manufacturer's published instructions. TABLE 21: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE • • ROOF COVER Insulation (Note 13) Roof Cover (Note 15A) System Deck MOP Attach Separator Sheet (Optional) No. (Note 1) Type Membrane Fasteners (Note 21) Attachment (psf) (Note 5) EverGuard TPO: IL EverGuard Polymat Drill-Tec XHD with Drill-Tec 2 3/8 in. Barbed XHD Min. 22 ga., type B, One or more layers, Prelim. i Separation Layer (3 oz/yd) or EverGuard Plates or Drill-Tec #15 EHD Fastener with Drill - 18-inch o.c. within 6-inch wide 5-470. Grade 80 steel any combination, attach EverGuard Polymat TPO Tec 2.4" Barbed Seam Plate or Drill-Tec 2.4" laps spaced 54-inch o.c. and -30.0 min. 1-inch Cushioning Layer (6 oz/ydt) Scoop Seam Plate sealed with a 1.5-inch heat weld. Drill-Tec XHD with Drill-Tec 2-3/8 in. Barbed XHD One or more layers, EverGuard Polymat Plates or Drill-Tec Eyehook AccuSeam Plates or 12-inch o.c. within 6-inch wide Min. 22 ga., type B, Prelim. Separation Layer oz/yda) or Ever Guard 5-471. Grade 33 steel any combination, attach EverGuard Polymat at TPO Drill-Tec #15 EHD Fastener with Drill-Tec 2.4" laps spaced 114-inch o.c. and -30.0 min. 1.5-inch Cushioning Layer (6 oz/yd�) Barbed Seam Plate or Drill-Tec 2.4" Scoop Seam sealed with a 1.5-inch heat weld. Plate One more layers, EverGuard Polymat 12-inch within wide 5-472. Min. 22 ga., type B, o any combination, Prelim. Separation Layer (3 oz/yd2) or EverGuard Drill-Tec XHD with Drill-Tec 2 in. Double Barbed h o.c. laps spaced 115-inch o.c. and spaced -30.0 Grade 80 steel min. 1.5-inch attach EverGuard Polymat TPO XHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer (6 oz/ydt) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 75 of 156 NNEMO I etc. EEL OR STRUCTURAL CONCRETE DECKS -NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER Insulation (Note 13) TYPE D-1: MECHANICALLY ATTACHEDSYSTEM ROOF Roof Cover (Note 15A) System Deck Separator Sheet (Optional) MDP Attach No. (Note 1) Type Membrane Fasteners (Note 11) Attachment (psf) (Note 5) EverGuard Polymat Drill-Tec XHD and Drill-Tec 2 in. Double Barbed 12-inch o.c. in rows spaced max. Min. 22 ga., type B, One or more layers, Prelim. Separation Layer oz/ydz ) or EverGuard Drill-Tec 2-3/8 in. Barbed XHD Plates XHD Plates, , 114-inch o.c. An 8-inch wide 5-473. Grade 33 steel any combination, attach at EverGuard Polymat TPO Drill-Tec Eyehook AccuSeam Plates or Drill-Tec cover strip is heat welded over -30.0 min. 1.5-inch Cushioning Layer (6 oz/yd') #15 EHD Fastener with Drill-Tec 2.4" Barbed the stress plates. Seam Plate or Drill-Tec 2.4" Scoop Seam Plate One or more layers, EverGuard Polymat 12-inch o.c. within 6-inch wide Min. 22 ga., type B, Prelim. Separation Layer (3 oz/ydi) or EverGuard Drill-Tec SXHD with Drill-Tec 2 3/4 in. Barbed S 474 Grade 33 steel any combination, attach EverGuard Polymat TPO SXHD Plates laps spaced 138-inch o.c. and -30.0 min. 1-inch Cushioning Layer (6 oz/yd') sealed with a 1.5-inch heat weld. EverGuard Polymat Drill-Tec XHD with Drill-Tec 2-3/8 in. Barbed XHD Min. 22 ga., type B, One or more layers, Prelim. a Separation Layer (3 oz/yd) or EverGuard Plates or Drill-Tec #15 EHD Fastener with Drill- 12-inch o.c. within 6-inch wide 5-475. Grade 60 steel any combination, attach EverGuard Polymat TPO Tec 2.4" Barbed Seam Plate or Drill-Tec 2.4" laps spaced 138-inch o.c. and -30.0 min. 1-inch Cushioning Layer (6 oz/ydz) Scoop Seam Plate sealed with a 1.5-inch heat weld. One or more layers, EverGuard Polymat 12-inch o.c. within 6-inch wide 5-476. Min. 22 ga., type B, any combination, Prelim. Separation Layer oz/ydi) or EverGuard Drill-Tec XHD or Drill-Tec SXHD with Drill-Tec 2 laps spaced 138-inch o.c. and -30.0 Grade 80 steel attach EverGuard Polymatat TPO 3/4 in. Barbed SXHD Plates min. 1-inch Cushioning Layer (6 oz/yd2) sealed with a 1.5-inch heat weld. EverGuard Polymat Drill-Tec XHD and Drill-Tec 2 in. Double Barbed Min. 22 ga., type B, One or more layers, Prelim. Separation Layer oz/yda) or EverGuardXHD Plates, Drill-Tec 2-3/8 in. Barbed XHD Plates, 6-inch o.c. within 6-inch wide S 477 Grade 33 steel any combination, attach EverGuard Polymat at TPO Drill-Tec Eyehook AccuSeam Plates or Drill-Tec laps spaced 138-inch o.c. and -30.0 min. 1-inch Cushioning Layer (6 oz/yd�) #15 EHD Fastener with Drill-Tec 2.4" Barbed sealed with a 1.5-inch heat weld. Seam Plate or Drill-Tec 2.4" Scoop Seam Plate One or more layers, EverGuard Polymat 12-inch o.c. within 6-inch wide S 478 Min. 22 ga., type B, any combination, Prelim. Separation Layer (3 oz/ydi) or EverGuard Drill-Tec XHD with Drill-Tec 2 in. Double Barbed laps spaced 90-inch o.c. and -37.5 Grade 33 steel min. 1-inch attach EverGuard Polymat TPO XHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer (6 oz/yd2) One or more layers, EverGuard Polymat 12-inch o.c. within 6-inch wide Min. 22 ga., type B, prelim. Separation Layer (3 oz/yd2) or EverGuard Drill-Tec SXHD with Drill-Tec 2 3/4 in. Barbed 5-479. Grade 40 steel any combination, attach EverGuard Polymat TPO SXHD Plates laps spaced 114-inch o.c. and -37.5 min. 1-inch Cushioning Layer (6 oz/yd2) sealed with a 1.5-inch heat weld. One or more layers, EverGuard Polymat 12-inch within wide Min. 22 ga., type B, Prelim. i Separation Layer (3 oz/yd) or EverGuard Drill-Tec XHD or SXHD with Drill-Tec 2 3/4 in. 5-480. Grade 80 steel any combination, attach EverGuard Polymat TPO Barbed SXHD Plates spaced laps spaced 114-inch o.c. and h o.c. -37.5 min. 1.5-inch Cushioning Layer (6 oz/yd2) sealed with a 1.5-inch heat weld. EverGuard Polymat Drill-Tec XHD with Drill-Tec 2 3/8 in. Barbed XHD Min. 22 ga., type B, One or more layers, Prelim. Separation Layer (3 oz/ydi) or EverGuard Plates or Drill-Tec #15 EHD Fastener with Drill- 12-inch o.c. within 5-inch wide 5-481. Grade 80 steel any combination, attach EverGuard Polymat TPO Tec 2.4" Barbed Seam Plate or Drill-Tec 2.4" laps spaced 115-inch o.c. and -37.5 min. 1.5-inch Cushioning Layer (6 oz/yd') Scoop Seam Plate sealed with a 1.5-inch heat weld. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMD ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 76 of 156 NNEMO I etc. EEL OR STRUCTURAL CONCRETE DECKS -NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER Insulation (Note 13) TYPE D-1: MECHANICALLY ATTACHEDSYSTEM ROOF Roof Cover (Note 15A) System Deck Separator Sheet (Optional) MOP Attach No. (Note 1) Type Membrane Fasteners (Note 11) Attachment (psf) (Note 5) One or more layers, EverGuard Polymat 12-inch o.c. within 6-inch wide Min. 22 ga., type B, Prelim. Separation Layer (3 oz/ydi) or EverGuard Drill-Tec SXHD with Drill-Tec 2 3/4 in. Barbed S 482 Grade 80 steel any combination, attach EverGuard Polymat TPO SXHD Plates laps spaced 138-inch o.c. and -37.5 min. 1-inch Cushioning Layer (6 oz/yd2) sealed with a 1.5-inch heat weld. One or more layers, EverGuard Polymat 12-inch o.c. within 6-inch wide prelim. Separation Layer (3 oz/yd2) or EverGuard Drill-Tec #14 Fasteners with Drill-Tec 2 3/4 in. 5-483. Structural concrete any combination, attach EverGuard Polymat TPO Barbed SXHD Plates laps spaced 138-inch o.c. and -37.5 min. 1-inch Cushioning Layer (6 oz/yd2) sealed with a 1.5-inch heat weld. EverGuard Polymat Drill-Tec XHD and Drill-Tec 2 in. Double Barbed Min. 20 ga., type B, One or more layers, Prelim. Separation Layer (3 oz/ydi) or EverGuard XHD Plates, Drill-Tec 2-3/8 in. Barbed XHD Plates, 6-inch o.c. within 6-inch wide S 484 Grade 33 steel any combination, attach EverGuard Polymat TPO Drill-Tec Eyehook AccuSeam Plates or Drill-Tec laps spaced 138-inch o.c. and -37.5 min. 1-inch Cushioning Layer (6 oz/yd2) #15 EHD Fastener with Drill-Tec 2.4" Barbed sealed with a 1.5-inch heat weld. Seam Plate or Drill-Tec 2.4" Scoop Seam Plate Drill-Tec XHD with Drill-Tec 2 in. Double Barbed EverGuard Polymat XHD Plates or Drill-Tec 2 3/8 in. Barbed XHD Min. 22 ga., type B, One or more layers, Prelim. Separation Layer (3 oz/yd') or EverGuard Plates; or Drill-Tec SXHD with Drill-Tec 2 3/4 in. 12-inch o.c. within 6-inch wide 5-485. Grade 33 steel any combination, attach EverGuard Polymat TPO Barbed SXHD Plates, or Drill-Tec #15 EHD laps spaced 54-inch o.c. and -45.0 min. 1-inch Cushioning Layer (6 oz/yd2) Fastener with Drill-Tec 2.4" Barbed Seam Plate sealed with a 1.5-inch heat weld. or Drill-Tec 2.4" Scoop Seam Plate EverGuard Polymat Drill-Tec XHD with Drill-Tec 2 in. Double Barbed Min. 22 ga., type B, Min. 200 psi, min. 2- Prelim. Separation Layer oz/yda) or EverGuard XHD Plates, Drill-Tec Eyehook AccuSeam Plates 12-inch o.c. within 6-inch wide 5-486. Grade 33 steel inch thick cellular attach at EverGuard Polymat TPO or Drill-Tec 2-3/8 in. Barbed XHD Plates or Drill- laps spaced 54-inch o.c. and -45.0 lightweight concrete Cushioning Layer (6 oz/ydi) Tec #15 EHD Fastener with Drill-Tec 2.4" Barbed sealed with a 1.5-inch heat weld. Seam Plate or Drill-Tec 2.4" Scoop Seam Plate One or more layers, EverGuard Polymat 12-inch o.c. within 6-inch wide S 487 Min. 22 ga., type B, any combination, Prelim. Separation Layer (3 oz/ydi) or EverGuard Drill-Tec XHD with Drill-Tec 2 in. Double Barbed laps spaced 66-inch o.c. and -45.0 Grade 40 steel min. 1-inch attach EverGuard Polymat TPO XHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer (6 oz/yd2) One more layers, EverGuard Polymat 12-inch within 6-inch wide Min. 22 ga., type B, prelim. Separation Layer (3 oz/yd2) or EverGuard Drill-Tec SXHD with Drill-Tec 2 3/4 in. Barbed 5-488. Grade 33 steel any combination, attach EverGuard Polymat TPO SXHD Plates laps spacceded 90-inch o.c. and -45.0 min. 1-inch Cushioning Layer (6 oz/yd2) sealed with a 1.5-inch heat weld. One more layers, EverGuard Polymat 12-inch within 6-inch wide 5-489. Min. 20 ga., type B, o any combination, Prelim. Separation Layer (3 oz/yd2) or EverGuard Drill-Tec XHD with Drill-Tec 2 3/4 in. Barbed laps spacceded 90-inch o.c. and -45.0 Grade 33 steel min. 1-inch attach EverGuard Polymat TPO SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer (6 oz/yd') NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 77 of 156 NNEMO I etc. EEL OR STRUCTURAL CONCRETE DECKS -NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER Insulation (Note 13) TYPE D-1: MECHANICALLY ATTACHEDSYSTEM ROOF Roof Cover (Note 15A) System Deck Separator Sheet (Optional) MOP Attach No. (Note 1) Type Membrane Fasteners (Note 11) Attachment (psf) (Note 5) EverGuard Polymat Drill-Tec XHD with Drill-Tec 2 3/8 in. Barbed XHD 6-inch o.c. within 5-inch wide Min. 22 ga., type B, One or more layers, Prelim. Separation Layer (3 oz/yd2) or EverGuard Plates or Drill-Tec #15 EHD Fastener with Drill- laps spaced 114.5-inch o.c. and 5-490. Grade 80 steel any combination, attach EverGuard Polymat TPO Tec 2.4" Barbed Seam Plate or Drill-Tec 2.4" sealed with a 1.75-inch heat -45.0 min. 1.5-inch Cushioning Layer (6 oz/yfl Scoop Seam Plate weld. One or more layers, EverGuard Polymat 12-inch o.c. within 6-inch wide Min. 22 ga., type B, prelim. Separation Layer (3 oz/yd2) or EverGuard Drill-Tec SXHD with Drill-Tec 2 3/4 in. Barbed 5-491. Grade 80 steel any combination, attach EverGuard Polymat TPO SXHD Plates laps spaced 114-inch o.c. and -45.0 min. 1-inch Cushioning Layer (6 oz/yd2) sealed with a 1.5-inch heat weld. Drill-Tec XHD with Drill-Tec 2-3/8 in. Barbed XHD EverGuard Polymat Plates, Drill-Tec Eyehook AccuSeam Plates or Min. 22 ga., type B, One or more layers, prelim. Separation Layer (3 oz/yd2) or EverGuard Drill-Tec 2 in. Double Barbed XHD Plates or Drill- 6-inch o.c. within 6-inch wide 5-492. any combination, Tec XHD or SXHD with Drill-Tec 2 3/4 in. Barbed laps spaced 138-inch o.c. and -45.0 Grade 60 steel min. 1-inch attach EverGuard Polymat TPO SXHD Plates or Drill-Tec #15 EHD Fastener with sealed with a 1.5-inch heat weld. Cushioning Layer (6 oz/yd2) Drill-Tec 2.4" Barbed Seam Plate or Drill-Tec 2.4" Scoop Seam Plate Drill-Tec XHD with Drill-Tec 2-3/8 in. Barbed XHD EverGuard Polymat Plates, Drill-Tec Eyehook AccuSeam Plates or Min. 18 ga., type B, One or more layers, prelim. Separation Layer (3 oz/yd2) or EverGuard Drill-Tec 2 in. Double Barbed XHD Plates or Drill- 6-inch o.c. within 6-inch wide 5-493. any combination, Tec XHD or SXHD with Drill-Tec 2 3/4 in. Barbed laps spaced 138-inch o.c. and -45.0 Grade 33 steel min. 1-inch attach EverGuard Polymat TPO SXHD Plates or Drill-Tec #15 EHD Fastener with sealed with a 1.5-inch heat weld. Cushioning Layer (6 oz/yd�) Drill-Tec 2.4" Barbed Seam Plate or Drill-Tec 2.4" Scoop Seam Plate Drill-Tec #14 Fasteners with Drill-Tec 2-3/8 in. One or more layers, EverGuard Polymat Barbed XHD Plates, Drill-Tec Eyehook AccuSeam 6-inch o.c. within 6-inch wide Prelim. Separation Layer (3 oz/yd:) or EverGuard Plates, Drill-Tec 2 in. Double Barbed XHD Plates 5-494. Structural concrete any combination, attach EverGuard Polymat TPO or Drill-Tec 2 3/4 in. Barbed SXHD Plates or Drill- laps spaced 138-inch o.c. and -45.0 min. 1-inch Cushioning Layer (6 oz/yd2) Tec #14 HD Fastener with Drill-Tec 2.4" Barbed sealed with a 1.5-inch heat weld. Seam Plate or Drill-Tec 2.4" Scoop Seam Plate One or more layers, EverGuard Polymat 12-inch o.c. within 6-inch wide Min. 22 ga., type B, Prelim. Separation Layer (3 oz/yda) or EverGuard Drill-Tec XHD with Drill-Tec 2 in. Double Barbed 5-495. Grade 40 steel any combination, attach EverGuard Polymat TPO XHD Plates laps spaced 54-inch o.c. and -52.5 min. 1-inch Cushioning Layer (6 oz/yd2) sealed with a 1.5-inch heat weld. One more layers, EverGuard Polymat 12-inch within 6-inch wide Min. 22 ga., type B, prelim. Separation Layer (3 oz/yfl or EverGuard Drill-Tec XHD with Drill-Tec 2 3/4 in. Barbed 5-496. Grade 40 steel any combination, attach EverGuard Polymat TPO SXHD Plates laps spaced 66-inch o.c. and -52.5 in. 1-inch Cushioning Layer (6 oz/yd2) sealed with a 1.5-inch heat weld. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 78 of 156 NNEMO I etc. EEL OR STRUCTURAL CONCRETE DECKS -NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER Insulation (Note 13) TYPE D-1: MECHANICALLY ATTACHEDSYSTEM ROOF Roof Cover (Note 15A) System Deck Separator Sheet (Optional) MOP Attach No. (Note 1) Type Membrane Fasteners (Note 11) Attachment (psf) (Note 5) Drill-Tec XHD with Drill-Tec 2-3/8 in. Barbed XHD One or more layers, EverGuard Polymat Plates, Drill-Tec Eyehook AccuSeam Plates or 6-inch o.c. within 6-inch wide Min. 22 ga., type B, Prelim. z Separation Layer (3 oz/yd) or EverGuard S 497 Grade 33 steel any combination, attach EverGuard Polymat TPO Drill-Tec 2 in. Double Barbed XHD Plates or Drill- laps spaced 114-inch o.c. and -52.5 min. 1-inch Cushioning Layer (6 oz/yd') Tec #15 EHD Fastener with Drill-Tec 2.4" Barbed sealed with a 1.5-inch heat weld. Seam Plate or Drill-Tec 2.4" Scoop Seam Plate Drill-Tec #14 or Drill-Tec CD-10 fasteners with One or more layers, Prelim. EverGuard Polymat Drill-Tec 2 in. Double Barbed XHD Plates, Drill - 6-inch o.c. within 6-inch wide Separation Layer (3 oz/yd:) or EverGuard Tec 2-3/8 in. Barbed XHD Plates or Drill-Tec 5-498. Structural concrete any combination, attach or EverGuard Polymat TPO Eyehook AccuSeam Plates or Drill-Tec #14 HD laps spaced 114-inch o.c. and -52.5 min. 1.5-inch OB500 Cushioning Layer (6 oz/yd2) Fastener with Drill-Tec 2.4" Barbed Seam Plate sealed with a 1.5-inch heat weld. or Drill-Tec 2.4" Scoop Seam Plate Drill-Tec XHD with Drill-Tec 2 3/8 in. Barbed XHD One or more layers, EverGuard Polymat Plates or Drill-Tec 2 in. Double Barbed XHD 6-inch o.c. within 5-inch wide Min. 22 ga., type B, Prelim. Separation Layer oz/ydi) or EverGuard S 499 Grade 80 steel any combination, attach EverGuard Polymatat TPO Plates or Drill-Tec #15 EHD Fastener with Drill- laps spaced 115-inch o.c. and -52.5 min. 1.5-inch Cushioning Layer (6 oz/yd') Tec 2.4" Barbed Seam Plate or Drill-Tec 2.4" sealed with a 1.5-inch heat weld. Scoop Seam Plate One or more layers, EverGuard Polymat 6-inch o.c. within 6-inch wide Min. 22 ga., type B, Prelim. Separation Layer (3 oz/ydz) or EverGuard Drill-Tec XHD or SXHD with Drill-Tec 2 3/4 in. 5-500. Grade 80 steel any combination, attach EverGuard Polymat TPO Barbed SXHD Plates laps spaced 138-inch o.c. and -52.5 min. 1-inch Cushioning Layer (6 oz/yd2) sealed with a 1.5-inch heat weld. One or more layers, EverGuard Polymat 6-inch o.c. within 6-inch wide 5-501. Structural concrete any combination, Prelim. Separation Layer (3 oz/yda) or EverGuard Drill-Tec #14 Fasteners with Drill-Tec 2 3/4 in. laps spaced 138-inch o.c. and -52.5 min. 1-inch attach EverGuard Polymat TPO Barbed SXHD Plates sealed with a 1.5-inch heat weld. Cushioning Layer (6 oz/yd2) EverGuard Polymat Drill-Tec XHD with Drill-Tec 2 3/8 in. Barbed XHD Min. 22 ga., type B, One or more layers, Prelim. Separation Layer (3 oz/ydi) or EverGuard Plates or Drill-Tec #15 EHD Fastener with Drill- 6-inch o.c. within 6-inch wide 5-502. Grade 33 steel any combination, attach EverGuard Polymat TPO Tec 2.4" Barbed Seam Plate or Drill-Tec 2.4" laps spaced 54-inch o.c. and -60.0 min. 1.5-inch Cushioning Layer (6 oz/yd2) Scoop Seam Plate sealed with a 1.5-inch heat weld. One or more layers, EverGuard Polymat 12-inch o.c. within 6-inch wide Min. 22 ga., type B, prelim. Separation Layer (3 oz/yd2) or EverGuard Drill-Tec XHD with Drill-Tec 2 3/4 in. Barbed 5-503. Grade 40 steel any combination, attach EverGuard Polymat TPO SXHD Plates laps spaced 54-inch o.c. and -60.0 min. 1-inch Cushioning Layer (6 oz/yd2) sealed with a 1.5-inch heat weld. One or more layers, EverGuard Polymat Drill-Tec XHD with Drill-Tec 2 3/8 in. Barbed XHD 6-inch o.c. within 6-inch wide 5-504. Min. 22 ga., type B, any combination, Prelim. Separation Layer (3 oz/ydi) or EverGuard Plates or Drill-Tec #15 EHD Fastener with Drill- laps spaced 90-inch o.c. and -60.0 Grade 33 steel min. 1-inch attach EverGuard Polymat TPO Tec 2.4" Barbed Seam Plate or Drill-Tec 2.4" sealed with a 1.5-inch heat weld. Cushioning Layer (6 oz/yd') Scoop Seam Plate NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 79 of 156 NNEMO I etc. EEL OR STRUCTURAL CONCRETE DECKS -NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER Insulation (Note 13) TYPE D-1: MECHANICALLY ATTACHEDSYSTEM ROOF Roof Cover (Note 15A) System Deck Separator Sheet (Optional) MDP Attach No. (Note 1) Type Membrane Fasteners (Note 11) Attachment (psf) (Note 5) One or more layers, EverGuard Polymat 6-inch o.c. within 6-inch wide Min. 22 ga., type B, Prelim. Separation Layer oz/ydi) or EverGuard Drill-Tec XHD with Drill-Tec 2 in. Double Barbed 5-505. Grade 33 steel any combination, attach at EverGuard Polymat TPO XHD Plates laps spaced 114-inch o.c. and -60.0 min. 1-inch Cushioning Layer (6 oz/yd2) sealed with a 1.5-inch heat weld. Min. 22 ga., type B, Min. psi, min. 2- prelim. EverGuard Polymat Separation Layer (3 oz/yd2) or EverGuard 12-inch within 6-inch wide 5-506. Grade 33 steel inch thichic k cellular attach EverGuard Polymat TPO Drill-Tec XHD with Drill-Tec 2-3/4 in. SXHD Plates laps spacedced 54-inch o.c. and -67.5 lightweight concrete Cushioning Layer (6 oz/ydz ) sealed with a 1.5-inch heat weld. EverGuard Polymat Fastened through to engage Min. 22 ga., type Min. 330 psi, min. 2- Separation Layer (3 oz/ydi) or EverGuard Drill-Tec XHD with Drill-Tec 2 in. Double Barbed steel deck, 6-inch o.c. within 6- 5-507. BV (0.5%), Grade inch thick Celcore N/A EverGuard Polymat TPO XHD Plates (to engage steel deck) inch wide laps spaced 114-inch -67.5 33 steel Cellular Concrete Cushioning Layer (6 oz/yd2) o.c. and sealed with a 1.5-inch heat weld. One or more layers, EverGuard Polymat 6-inch o.c. within 6-inch wide 5-508. Min. 22 ga., type B, any combination, Prelim. i Separation Layer (3 oz/yd) or EverGuard Drill-Tec XHD with Drill-Tec 2 3/4 in. Barbed laps spaced 114-inch o.c. and -67.5 Grade 33 steel attach EverGuard Polymat TPO SXHD Plates min. 1-inch Cushioning Layer (6 oz/yd2) sealed with a 1.5-inch heat weld. 6-inch o.c. atop 6-inch wide One or more layers, EverGuard Polymat EverGuard overlaps in rows spaced max. Min. 22 ga., Type B, Prelim. a Separation Layer (3 oz/yd) or Drill-Tec XHD with Drill-Tec 2 3/8 in. Barbed XHD 138-inch o.c. An 8-inch wide 5-509. Grade 80 steel any combination, attach EverGuard Polymat TPO, min. Plates or Drill-Tec Eyehook AccuSeam Plates cover strip is heat welded 1.5- -67.5 min. 1-inch Cushioning Layer (6 oz/yd2) 60-m il inch on both sides of the fastener rows One or more layers, EverGuard Polymat Min. 18 ga., type B, min. 1.5-inch 5 parts Separation Layer (3 oz/ydi) or EverGuard Drill-Tec XHD Fasteners with Drill-Tec 2 in. 6-inch o.c. within 6-inch wide 5-510. Grade 33 steel EnergyGuard Polyiso per 4 x 4 EverGuard Polymat TPO Double Barbed XHD Plates laps spaced 114-inch o.c. and -90.0 Insulation, ft board Cushioning Layer (6 oz/yd�) sealed with a 1.5-inch heat weld. EnergyGuard Ultra EverGuard TPO Fleece -Back Membrane: Drill-Tec XHD (steel only) or Drill-Tec #14 Min. 22 ga., type B, One more layers, EverGuard Fasteners (concrete only) with Drill-Tec 2 3/8 in. 6-inch o.c. within min. 6-inch 5-511. Grade 33 steel or o any combination, prelim. N/A TPO Fleece- Barbed XHD Plates or Drill-Tec #15 EHD Fastener wide laps spaced 114-inch o.c. -45.0 structrural min. 1.5-inch attach Back (steel only) or Drill-Tec #14 HD Fastener and sealed with a 1.625-inch concrete Membrane (concrete only) with Drill-Tec 2.4" Barbed Seam heat weld. Plate or Drill-Tec 2.4" Scoop Seam Plate NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 71h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 80 of 156 NNEMO I etc. EEL OR STRUCTURAL CONCRETE DECKS -NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER Insulation (Note 13) TYPE D-1: MECHANICALLY ATTACHEDSYSTEM ROOF Roof Cover (Note 15A) System Deck Separator Sheet (Optional) MDP Attach No. (Note 1) Type Membrane Fasteners (Note 11) Attachment (psf) (Note 5) Drill-Tec XHD with Drill-Tec 2 in. Double Barbed Min. 200 psi, min. 2- EverGuard XHD Plates, Drill-Tec Eyehook AccuSeam Plates 12-inch o.c. within 6-inch wide 5-512. Min. 22 a., type B, g inch thick cellular Prel im. N/A TPO Fleece- or Drill-Tec 2-3/8 in. Barbed XHD Plates or Drill- laps spaced 54-inch o.c. and -45.0 Grade 33 steel lightweight concrete attach Back Tec #15 EHD Fastener with Drill-Tec 2.4" Barbed sealed with a 1.5-inch heat weld. Membrane Seam Plate or Drill-Tec 2.4" Scoop Seam Plate Drill-Tec XHD (steel only) or Drill-Tec #14 Min. 22 ga., type B, a EverGuard Fasteners (concrete only) with Drill-Tec 2 3/8 in. 6-inch o.c. within min. 6-inch One or more layers, 5-513. Grade 33 steel any combination, prelim. N/A TPO Fleece- Barbed XHD Plates or Drill-Tec #15 EHD Fastener wide laps spaced 112.5-inch o.c. -60.0 structrural attach Back (steel only) or Drill-Tec #14 HD Fastener and sealed with a 1.625-inch concrete min. 1.5-inch Membrane (concrete only) with Drill-Tec 2.4" Barbed Seam heat weld. Plate or Drill-Tec 2.4" Scoop Seam Plate EverGuard Min. 22 ga., type B, Min. psi, min. 2- prelim. TPO Fleece- 12-inch o.c. within 6-inch wide 5-514. inch thichic k cellular N/A Drill-Tec XHD with Drill-Tec 2-3/4 in. SXHD Plates laps spaced 54-inch o.c. and -67.5 Grade 33 steel lightweight concrete attach Back Membrane sealed with a 1.5-inch heat weld. Fastened through to engage Min. 200 psi, min. 3- EverGuard Min. 22 ga., type inch thick Elastizell TPO Fleece- Drill-Tec XHD with Drill-Tec 2 in. Double Barbed steel deck, 6-inch o.c. within 6- 5-515. BV (0.5%), Grade N/A N/A inch wide laps spaced 114-inch -75.0 33 steel Lightweight Back XHD Plates (to engage steel deck) o.c. and sealed with a 1.5-inch Insulating Concrete Membrane heat weld. CONCRETETABLE 2j: STEEL OR STRUCTURAL ••• •RECOVER An Deck SYSTEM TYPE D-2: INSULATED, Insulation Layer(s) (Note 13) MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Base or Anchor Sheet MOP Type Attach Base Fasteners Attach System No. (Note 1) Roof Cover (psf) (Note 11) Min. 22 ga., type B, Grade 33 One or more layers, GAF StormSafe Anchor Note 2 (no 12-inch o.c. at min. 4-inch laps and 12- EverGuard Freedom TPO / self 5-516. steel or min. 2,500 psi any combination Loose -laid Sheet (48-inch wide) recessed inch o.c. in two, equally spaced, adhered -45.0 structrual concrete plate) staggered center rows Min. 22 ga., type B, Grade 33 One or more layers, GAF StormSafe Anchor Note 2 (no 18-inch o.c. at min. 4-inch laps and 18- EverGuard Freedom TPO /self 5-517. steel or min. 2,500 psi any combination Loose -laid Sheet (48-inch wide) recessed inch o.c. in two, equally spaced, adhered -52.5 structrual concrete plate) staggered center rows NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 certificate of Authorization #32455 71h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 81 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR .. (TEAR -OFF) TYPE A-1: BONDED INSULATION, BONDED ROOF COVER OPTIONSSYSTEM REFER To NOTE 1-6- FOR VAPOR BARRIER Base Insulation Layer Top Insulation Layer System Deck MDP Attach Attach Roof Cover (Note 15) No. (Note 1) Type Type (Psf) (Notes 6,7,8) (Notes 6,7,8) EverGuard Freedom TPO: Structural Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard Freedom TPO / self C-1. GAF 2-Part (Optional) Additional layer of base insulation GAF 2-Part -142.5 concrete EnergyGuard Ultra adhered Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard Freedom TPO / self C 2. GAF 2-Part followed by min. 0.25-inch SECUROCK Gypsum- GAF 2-Part -232.5 concrete EnergyGuard Ultra Fiber Roof Board adhered Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard Freedom TPO / self C-3. concrete EnergyGuard RN GAF 2-Part Board GAF 2-Part adhered -382.5 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso EverGuard Freedom TPO / self C-4. LRF-M Insulation, EnergyGuard HD Polyiso Insulation, LRF-M 97.5 concrete 1.5-inch EnergyGuard RH EnergyGuard HD Plus Polyiso Insulation adhered Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard Freedom TPO / self C-5. LRF-M followed by Min. 0.25-inch SECUROCK Gypsum- LRF-M -232.5 concrete EnergyGuard Ultra Fiber Roof Board adhered Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard Freedom TPO / self C-6. LRF-M (Optional) Additional layers of base insulation LRF-M 292 5 concrete EnergyGuard Ultra adhered Structural Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard Freedom TPO / self C 7 LRF-XF (Optional) Additional layer of base insulation LRF-XF -142.5 concrete EnergyGuard Ultra adhered Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard Freedom TPO self C 8 LRF-XF followed by min. 0.25-inch SECUROCK Gypsum- LRF-XF -232.5 concrete EnergyGuard Ultra Fiber Roof Board adhered Structural Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard Freedom TPO / self C 9 Min. 1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF LRF-XF -382.5 concrete Board adhered Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or EverGuard Freedom TPO / self C-10. concrete EnergyGuard RN OB500 (Optional) Additional layer of base insulation OB500 adhered -37.5 Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard Freedom TPO / self C-11. concrete EnergyGuard RN OB500 Board OB500 adhered -37.5 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso EverGuard Freedom TPO / self C-12. OB500 Insulation, EnergyGuard HD Polyiso Insulation, OB500 -37.5 concrete 1.5-inch EnergyGuard RH EnergyGuard HD Plus Polyiso Insulation adhered Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or EverGuard Freedom TPO / self C-13. OB500 (Optional) Additional layer of base insulation OB500 -52.5 concrete EnergyGuard RN adhered Structural Min. Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso EverGuard Freedom TPO / self C-14. OB500 Insulation, EnergyGuard HD Polyiso Insulation, OB500 97.5 concrete EnergyGuard RH EnergyGuard HD Plus Polyiso Insulation adhered NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 82 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso EverGuard Freedom TPO / self C-15. concrete 1.5-inch EnergyGuard RH OB500 Insulation, EnergyGuard HD Polyiso Insulation, OB500 adhered 97.5 EnergyGuard HD Plus Polyiso Insulation Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard Freedom TPO / self C-16. concrete EnergyGuard RN Og500 Board OB500 adhered -127.5 Structural EverGuard Freedom TPO / self C-17. Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Board OB500 None -230.0 concrete adhered Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard Freedom TPO / self C-18. OB500 followed by Min. 0.25-inch SECUROCK Gypsum- OB500 -232.5 concrete EnergyGuard Ultra Fiber Roof Board adhered Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard Freedom TPO / self C-19. OB500 (Optional) Additional layers of base insulation OB500 -292.5 concrete EnergyGuard Ultra adhered Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard Freedom TPO / self C-20. concrete EnergyGuard RN OB500 Board OB500 adhered -347.5 Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or in. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard Freedom TPO / self C-21. concrete EnergyGuard RN OB500 Board OB500 adhered -382.5 EverGuard TPO / EverGuard TPO #1121 Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or (Optional) Min. 0.25-inch DensDeck Prime or EverGuard TPO / #1121, TPO 3- C 22 concrete EnergyGuard RN Hot Asphalt min. 7/16-inch OSB Hot asphalt Square _q5.0 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / #1121, TPO 3- C-23. GAF 2-Part followed by min. 0.5-inch Structodek High GAF 2-Part 82.5 concrete EnergyGuard Ultra Density Fiberboard Roof Insulation Square Structural Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / #1121, TPO 3- C 2q Min. 1.5-inch thick, min. 1.25 pcf Insulfoam EPS GAF 2-Part GAF 2-Part 87 5 concrete Gypsum -Fiber Roof Board Square Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / #1121, TPO 3- C-25. EnergyGuard RN or Min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part Min. 0.25-inch DensDeck or DensDeck Prime GAF 2-Part -130.0 concrete Insulfoam EPS Square Structural One or more layers, min. 1.5-inch thick, min. 1.5 pcf Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / #1121, TPO 3- C-26. concrete Insulfoam EPS GAF 2-Part Board GAF 2-Part Square _180.0 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / #1121, TPO 3- C 27. GAF 2-Part (Optional) Additional layers of base insulation GAF 2-Part -232.5 concrete EnergyGuard Ultra Square Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / #1121, TPO 3- C 28 GAF 2-Part followed by min. 0.25-inch DensDeck Prime or GAF 2-Part -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board Square Structural One or more layers, min. 1.5-inch thick, min. 2.0 pcf Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / #1121, TPO 3- C 29 concrete Insulfoam EPS GAF 2-Part Board GAF 2-Part I I Square -240.0 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 83 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min. 2-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / #1121, TPO 3- C-30. concrete EnergyGuard RN GAF 2-Part Board GAF 2-Part Square 247 5 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / #1121, TPO 3- C-31. LRF-M followed by min. 0.5-inch Structodek High LRF-M 82.5 concrete EnergyGuard Ultra Density Fiberboard Roof Insulation Square Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO / #1121, TPO 3- C-32. concrete 1.5-inch EnergyGuard RH LRF-M Insulation, EnergyGuard HD Polyiso Insulation, LRF-M Square 97.5 EnergyGuard HD Plus Polyiso Insulation Structural EverGuard TPO / #1121, TPO 3- C-33. Min. 1-inch EnergyGuard RH LRF-M (Optional) Additional layer of base insulation LRF-M -162.5 concrete Square Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / #1121, TPO 3- C-34. LRF-M followed by Min. 0.25-inch DensDeck Prime or LRF-M -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board Square Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / #1121, TPO 3- C-35. LRF-M (Optional) Additional layers of base insulation LRF-M 292 5 concrete EnergyGuard Ultra Square Structural EverGuard TPO / #1121, TPO 3- C-36. Min. 1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF -130.0 concrete Square Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / #1121, TPO 3- C-37. LRF-XF (Optional) Additional layers of base insulation LRF-XF _232.5 concrete EnergyGuard Ultra Square Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / #1121, TPO 3- C-38. LRF-XF followed by min. 0.25-inch DensDeck Prime or LRF-XF -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board Square Structural Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / #1121, TPO 3- C-39. concrete Min. 2-inch EnergyGuard RA or EnergyGuard RH LRF-XF Board LRF-XF Square 247 5 Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / #1121, TPO 3- C-40. OB500 (Optional) Additional layer of base insulation OB500 -37.5 concrete EnergyGuard RN Square Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / #1121, TPO 3- C-41. concrete EnergyGuard RN OB500 Gypsum -Fiber Roof Board OB500 Square -37.5 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO / #1121, TPO 3- C 42 OB500 Insulation, EnergyGuard HD Polyiso Insulation, OB500 -37.5 concrete 1.5-inch EnergyGuard RH EnergyGuard HD Plus Polyiso Insulation Square Structural EverGuard TPO / #1121, TPO 3- C-43. concrete Min. 1.5-inch Insulfoam OB500 Min. 0.25-inch DensDeck Prime OB500 Square -45.0 Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / #1121, TPO 3- C 44 OB500 (Optional) Additional layer of base insulation OB500 _45.0 concrete EnergyGuard RN I Square Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / #1121, TPO 3- C-45. concrete EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 Square -52.5 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 84 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / #1121, TPO 3- C-46. concrete EnergyGuard Ultra OB500 followed by min. 0.5-inch Structodek High OB500 Square 82.5 Density Fiberboard Roof Insulation Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO / #1121, TPO 3- C-47. OB500 Insulation, EnergyGuard HD Polyiso Insulation, OB500 97.5 concrete 1.5-inch EnergyGuard RH EnergyGuard HD Plus Polyiso Insulation Square Structural EverGuard TPO / #1121, TPO 3- C 48 Min. 2-inch, min. 2.0 pcf, Insulfoam EPS OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 -120.0 concrete Square Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / #1121, TPO 3- C 49 concrete EnergyGuard RN OB500 Board OB500 Square -127.5 Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / #1121, TPO 3- C-50. concrete EnergyGuard RN OB500 Min. 0.25-inch DensDeck or DensDeck Prime OBS00 Square -130.0 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / #1121, TPO 3- C-51. OB500 followed by min. 0.25-inch DensDeck Prime or OB500 -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board Square Structural Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / #1121, TPO 3- C-52. concrete Min. 1.5-inch EnergyGuard RA or EnergyGuard RN OB500 Gypsum -Fiber Roof Board OB500 Square -240.0 Structural Min. 2-inch EnergyGuard Polyiso Insulation, Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / #1121, TPO 3- C-53. EnergyGuard RA, EnergyGuard RH or EnergyGuard OB500 OB500 -247.5 concrete RN Board Square Structural EverGuard TPO / #1121, TPO 3- C-54. Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer of base insulation OB500 -270.0 concrete Square Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / #1121, TPO 3- C-55. OB500 I (Optional) Additional layers of base insulation OB500 292 5 concrete EnergyGuard Ultra Square Structural Min. 1-inch EnergyGuard Polyiso Insulation, EverGuard TPO / #1121, TPO 3- C-56. OB500 None N/A -502.5 concrete EnergyGuard RA Square EverGuard TPO / EverGuard WB181 Bonding Adhesive: C-57. Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or Hot asphalt (Optional) Additional layer of base insulation Hot asphalt EverGuard TPO / WB181 -135.0 concrete EnergyGuard RN C-58. Structural Min. 1.5-inch thick, min. 1.25 pcf Insulfoam EPS GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part EverGuard TPO / WB181 -87.5 concrete Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or C-59. EnergyGuard RN or Min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part EverGuard TPO / WB181 -130.0 concrete Insulfoam EPS Additional optional layers base insulation C-60. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part followed by min. 0.25-inch DensDeck Prime or GAF 2-Part EverGuard TPO / WB181 -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 85 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,81 C-61. Structural Min. 1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional) Additional layer of base insulation GAF 2-Part EverGuard TPO / WB181 -270.0 concrete EnergyGuard Ultra Min. 0.5-inch EnergyGuard RH HD Polyiso C-62. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. LRF-M Insulation, EnergyGuard HD Polyiso Insulation, LRF-M EverGuard TPO / WB181 -97.5 concrete 1.5-inch EnergyGuard RH EnergyGuard HD Plus Polyiso Insulation C-63. Structural Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Board LRF-M None N/A EverGuard TPO / WB181 -112.5 concrete C-64. Structural Min. 1-inch EnergyGuard RH LRF-M (Optional) Additional layer of base insulation LRF-M EverGuard TPO / W6181 -162.5 concrete Additional optional layers base insulation C-65. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-M followed by min. 0.25-inch DensDeck Prime or LRF-M EverGuard TPO / WB181 -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board C-66. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-M (Optional) Additional layers of base insulation LRF-M EverGuard TPO / W6181 -292.5 concrete EnergyGuard Ultra C-67. Structural Min. 1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF EverGuard TPO / W6181 -130.0 concrete Additional optional layers base insulation C-68. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-XF followed by min. 0.25-inch DensDeck Prime or LRF-XF EverGuard TPO / WB181 -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board C-69. Structural Min. 1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional) Additional layer of base insulation LRF-XF EverGuard TPO / W6181 -270.0 concrete EnergyGuard Ultra C-70. Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or OB500 (Optional) Additional layer of base insulation OB500 EverGuard TPO / WB181 -37.5 concrete EnergyGuard RN C-71. Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or OB500 Min. 0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO / WB181 -37.5 concrete EnergyGuard RN Gypsum -Fiber Roof Board Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso C-72. OB500 Insulation, EnergyGuard HD Polyiso Insulation, OBSOO EverGuard TPO / WB181 -37.5 concrete 1.5-inch EnergyGuard RH EnergyGuard HD Plus Polyiso Insulation C-73. Structural Min. 1.5-inch Insulfoam OB500 Min. 0.25-inch DensDeck Prime OB500 EverGuard TPO / WB181 -45.0 concrete C-74. Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or OB500 (Optional) Additional layer of base insulation OB500 EverGuard TPO / WB181 -45.0 concrete EnergyGuard RN C-75. Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or OB500 Min. 0.25-inch DensDeck Prime or SECUROCK OB500 EverGuard TPO / WB181 -52.5 concrete EnergyGuard RN Gypsum -Fiber Roof Board Min. 0.5-inch EnergyGuard RH HD Polyiso C-76. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. OB500 Insulation, EnergyGuard HD Polyiso Insulation, OB500 EverGuard TPO / WB181 -97.5 concrete 1.5-inch EnergyGuard RH EnergyGuard HD Plus Polyiso Insulation NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 86 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8) Min. 0.5-inch EnergyGuard RH HD Polyiso C 77. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. OB500 Insulation, EnergyGuard HD Polyiso Insulation, OB500 EverGuard TPO / WB181 -97.5 concrete 1.5-inch EnergyGuard RH EnergyGuard HD Plus Polyiso Insulation Structural C 78 Min. 2-inch, min. 2.0 pcf, Insulfoam EPS OB500 Min. 0.25-inch DensDeck Prime OB500 EverGuard TPO / WB181 -120.0 concrete C 79 Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or OBS00 Min. 0.25-inch DensDeck Prime OB500 EverGuard TPO / WB181 -130.0 concrete EnergyGuard RN C-80. Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or OB500 Min. 0.25-inch DensDeck Prime OB500 EverGuard TPO / WB181 -135.0 concrete EnergyGuard RN Structural C-81. Min. 1-inch EnergyGuard RA OB500 None N/A EverGuard TPO / WB181 -215.0 concrete Additional optional layers base insulation C 82. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, OB500 followed by min. 0.25-inch DensDeck Prime or OB500 EverGuard TPO / WB181 -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board C-83. Structural Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer of base insulation OB500 EverGuard TPO / WB181 -270.0 concrete C-84. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, OB500 (Optional) Additional layers of base insulation OB500 EverGuard TPO / WB181 -292.5 concrete EnergyGuard Ultra EverGuard TPO / EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Ir- Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / TPO 6-Square, C-85. Hot Asphalt (Optional) Min. 0.25-inch DensDeck Prime Hot asphalt -45.0 concrete EnergyGuard RN TPO 3-Square Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / TPO 6-Square, C-86. EnergyGuard RN or min. 1.5-inch thick, min. 1.25 pcf GAF 2-Part GAF 2-Part -45.0 concrete Insulfoam EPS Gypsum -Fiber Roof Board TPO 3-Square Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / TPO 6-Square, C 87. GAF 2-Part followed by min. 0.5-inch Structodek High GAF 2-Part 82.5 concrete EnergyGuard Ultra Density Fiberboard Roof Insulation TPO 3-Square Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / TPO 6-Square, C 88. GAF 2-Part followed by min. 0.25-inch DensDeck Prime or GAF 2-Part -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board TPO 3-Square Structural Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / TPO 6-Square, C 89 GAF 2-Part (Optional) Additional layer of base insulation GAF 2-Part -270.0 concrete I EnergyGuard Ultra TPO 3-Square Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / TPO 6-Square, C-90. LRF-M followed by min. 0.5-inch Structodek High LRF-M 82.5 concrete EnergyGuard Ultra Density Fiberboard Roof Insulation TPO 3-Square NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 87 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO / TPO 6-Square, C-91. concrete 1.5-inch EnergyGuard RH LRF-M Insulation, EnergyGuard HD Polyiso Insulation, LRF-M TPO 3-Square 97.5 EnergyGuard HD Plus Polyiso Insulation Structural EverGuard TPO / TPO 6-Square, C 92 Min. 1-inch EnergyGuard RH LRF-M (Optional) Additional layer of base insulation LRF-M -162.5 concrete TPO 3-Square Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / TPO 6-Square, C-93. concrete EnergyGuard Ultra LRF-M followed by min. 0.25-inch DensDeck Prime or LRF-M TPO 3-Square -232.5 SECUROCK Gypsum -Fiber Roof Board Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / TPO 6-Square, C-94. LRF-M (Optional) Additional layers of base insulation LRF-M -240.0 concrete EnergyGuard Ultra TPO 3-Square Structural Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO /TPO 6-Square, C-95. Min.0.5-inch EnergyGuard RH LRF-M LRF-M -360.0 concrete Board TPO 3-Square Structural Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / TPO 6-Square, C-96. concrete Min. 1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF Gypsum -Fiber Roof Board LRF-XF TPO 3-Square -45.0 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / TPO 6-Square, C-97. LRF-XF followed by min. 0.25-inch DensDeck Prime or LRF-XF -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board TPO 3-Square Structural Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / TPO 6-Square, C 98 LRF-XF (Optional) Additional layer of base insulation LRF-XF -270.0 concrete EnergyGuard Ultra TPO 3-Square Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / TPO 6-Square, C 99 OB500 (Optional) Additional layer of base insulation OB500 -37.5 concrete EnergyGuard RN TPO 3-Square Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / TPO 6-Square, C-100. concrete EnergyGuard RN OB500 Gypsum -Fiber Roof Board OB500 TPO 3-Square -37.5 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO / TPO 6-Square, C-101. OBS00 Insulation, EnergyGuard HD Polyiso Insulation, OB500 -37.5 concrete 1.5-inch EnergyGuard RH EnergyGuard HD Plus Polyiso Insulation TPO 3-Square Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / TPO 6-Square, C-102. EnergyGuard RN, min. 2-inch, min. 2.0 pcf, Insulfoam OB500 OB500 -45.0 concrete EPS or min. 1.5-inch Insulfoam Gypsum -Fiber Roof Board TPO 3-Square Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / TPO 6-Square, C-103. OBS00 (Optional) Additional layer of base insulation OBS00 -45.0 concrete EnergyGuard RN TPO 3-Square Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / TPO 6-Square, C-104. concrete EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 TPO 3-Square -45.0 Additional optional layers base insulation Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, followed by EverGuard TPO / TPO 6-Square, C-105. concrete EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density OB500 TPO 3-Square 82 5 Fiberboard Roof Insulation NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 88 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO / TPO 6-Square, C-106. concrete 1.5-inch EnergyGuard RH OB500 Insulation, EnergyGuard HD Polyiso Insulation, OB500 TPO 3-Square 97.5 EnergyGuard HD Plus Polyiso Insulation Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO / TPO 6-Square, C-107. OB500 Insulation, EnergyGuard HD Polyiso Insulation, OB500 97.5 concrete 1.5-inch EnergyGuard RH EnergyGuard HD Plus Polyiso Insulation TPO 3-Square Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / TPO 6-Square, C-108. concrete EnergyGuard RN OB500 Board OB500 TPO 3-Square -127.5 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / TPO 6-Square, C-109. OB500 followed by min. 0.25-inch DensDeck Prime or OB500 -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board TPO 3-Square Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / TPO 6-Square, C-110. OB500 (Optional) Additional layers of base insulation OB500 -240.0 concrete EnergyGuard Ultra TPO 3-Square Structural EverGuard TPO / TPO 6-Square, C-111. Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer of base insulation OB500 -270.0 concrete TPO 3-Square Structural Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / TPO 6-Square, C-112. concrete Min. 1-inch EnergyGuard RH OB500 Board OB500 TPO 3-Square -502.5 EverGuard TPO / EverGuard TPO Quick Spray or EverGuard TPO Quick Spray LV SO: Structural EverGuard TPO / TPO QSA or TPO C-113. Min. 0.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional) Additional layers of base insulation GAF 2-Part 82.5 concrete QSA LV50 C-114. Structural Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional) Additional layer of base insulation GAF 2-Part EverGuard TPO / TPO QSA LV50 -270.0 concrete Structural EverGuard TPO / TPO QSA or TPO C-115. Min. 1.5-inch thick, min. 1.25 pcf Insulfoam EPS GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part 87 5 concrete QSA LV50 Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / TPO QSA or TPO C-116. EnergyGuard RN or Min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part -130.0 concrete Insulfoam EPS QSA LV50 C-117. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part Additional optional layers base insulation GAF 2-Part EverGuard TPO / TPO QSA LV50 -202.5 concrete EnergyGuard Ultra followed by min. 0.25-inch DensDeck Prime C-118. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part Additional optional layers base insulation GAF 2-Part EverGuard TPO / TPO QSA -232.5 concrete EnergyGuard Ultra followed by min. 0.25-inch DensDeck Prime C-119. Structural Min. 1.5-inch thick, min. 1.25 pcf Insulfoam EPS GAF 2-Part Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part EverGuard TPO / TPO QSA LV50 -87.5 concrete Board Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Min. 0.25-inch SECUROCK Gypsum -Fiber Roof C-120. EnergyGuard Ultra Polyiso Insulation, EnergyGuard GAF 2-Part GAF 2-Part EverGuard TPO / TPO QSA -90.0 concrete RA, or EnergyGuard RN Board NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 89 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8( C-121. Structural One or more layers, min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part EverGuard TPO / TPO QSA LV50 -180.0 concrete Insulfoam EPS Board Additional optional layers base insulation C-122. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part followed by min. 0.25-inch SECUROCK Gypsum- GAF 2-Part EverGuard TPO / TPO QSA LV50 -232.5 concrete EnergyGuard Ultra Fiber Roof Board Additional optional layers base insulation C-123. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part followed by min. 0.25-inch SECUROCK Gypsum- GAF 2-Part EverGuard TPO / TPO QSA LV50 -232.5 concrete EnergyGuard Ultra Fiber Roof Board C-124. Structural One or more layers, min. 1.5-inch thick, min. 2.0 pcf GAF 2-Part Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part EverGuard TPO / TPO QSA LV50 -240.0 concrete Insulfoam EPS Board C-125. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional) Additional layers of base insulation LRF-M EverGuard TPO / TPO QSA -82.5 concrete C-126. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional) Additional layers of base insulation LRF-M EverGuard TPO / TPO QSA LV50 -292.5 concrete Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard HD Polyiso EverGuard TPO / TPO QSA or TPO C-127. concrete 1.5-inch EnergyGuard RH LRF-M Insulation LRF-M QSA LV50 g7 5 C-128. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-M Additional optional layers base insulation LRF-M EverGuard TPO / TPO QSA LV50 -202.5 concrete EnergyGuard Ultra followed by min. 0.25-inch DensDeck Prime C-129. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-M Additional optional layers base insulation LRF-M EverGuard TPO / TPO QSA -232.5 concrete EnergyGuard Ultra followed by min. 0.25-inch DensDeck Prime C-130. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-M Min. 0.25-inch SECUROCK Gypsum -Fiber Roof LRF-M EverGuard TPO / TPO QSA -97.5 concrete EnergyGuard Ultra Board Additional optional layers base insulation C-131. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-M followed by Min. 0.25-inch SECUROCK Gypsum- LRF-M EverGuard TPO / TPO QSA LV50 -232.5 concrete EnergyGuard Ultra Fiber Roof Board Structural EverGuard TPO / TPO QSA or TPO C-132. Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional) Additional layers of base insulation LRF-XF 82 5 concrete QSA LV50 C-133. Structural Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional) Additional layer of base insulation LRF-XF EverGuard TPO / TPO QSA LV50 -270.0 concrete Structural EverGuard TPO / TPO QSA or TPO C-134. Min. 1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF -130.0 concrete QSA LV50 C-135. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-XF Additional optional layers base insulation LRF-XF EverGuard TPO / TPO QSA LV50 -202.5 concrete EnergyGuard Ultra followed by min. 0.25-inch DensDeck Prime C-136. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-XF Additional optional layers base insulation LRF-XF EverGuard TPO / TPO QSA -232.5 concrete EnergyGuard Ultra followed by min. 0.25-inch DensDeck Prime NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 90 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8( Min. 0.5-inch EnergyGuard Polyiso Insulation, C-137. Structural EnergyGuard Ultra Polyiso Insulation or EnergyGuard LRF-XF Min. 0.25-inch SECUROCK Gypsum -Fiber Roof LRF-XF EverGuard TPO / TPO QSA -90.0 concrete R Board Additional optional layers base insulation C-138. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-XF followed by min. 0.25-inch SECUROCK Gypsum- LRF-XF EverGuard TPO / TPO QSA LV50 -232.5 concrete EnergyGuard Ultra Fiber Roof Board Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation C-139. LRF-XF followed by min. 0.25-inch SECUROCK Gypsum- LRF-XF EverGuard TPO / TPO QSA LV50 -232.5 concrete EnergyGuard Ultra Fiber Roof Board Structural EverGuard TPO / TPO QSA or TPO C-140. Min. 1-inch EnergyGuard RA OB500 (Optional) Additional layer of base insulation OB500 -45.0 concrete QSA LV50 Structural EverGuard TPO / TPO QSA or TPO C-141. Min. 1-inch EnergyGuard RA OB500 None N/A -75.0 concrete QSA LV50 C-142. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation OB500 (Optional) Additional layers of base insulation OB500 EverGuard TPO / TPO QSA -82.5 concrete C-143. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation OB500 (Optional) Additional layers of base insulation OB500 EverGuard TPO / TPO QSA LV50 -292.5 concrete Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard HD Polyiso EverGuard TPO / TPO QSA or TPO C-144. concrete 1.5-inch EnergyGuard RH OB500 Insulation OB500 QSA LV50 97 5 Structural EverGuard TPO / TPO QSA or TPO C-145. concrete Min. 1.5-inch Insulfoam OB500 Min. 0.25-inch DensDeck Prime OB500 QSA LV50 -45.0 C-146. Structural Min. 2-inch Insulfoam I OB500 Min. 0.25-inch DensDeck Prime OB500 EverGuard TPO /TPO QSA -120.0 concrete Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / TPO QSA or TPO C-147. concrete EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 QSA LV50 -135.0 C-148. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, OB500 Additional optional layers base insulation OB500 EverGuard TPO / TPO QSA LV50 -202.5 concrete EnergyGuard Ultra followed by min. 0.25-inch DensDeck Prime C-149. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, OB500 Additional optional layers base insulation OB500 EverGuard TPO / TPO QSA -232.5 concrete EnergyGuard Ultra followed by min. 0.25-inch DensDeck Prime C-150. Structural Min. 1.5-inch EnergyGuard RA or EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 EverGuard TPO / TPO QSA -240.0 concrete Structural Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / TPO QSA or TPO C-151. concrete Min. 1.5-inch Insulfoam OB500 Board OB500 QSA LV50 -45.0 Min. 0.5-inch EnergyGuard Polyiso Insulation, C-152. Structural EnergyGuard Ultra, min. 1-inch EnergyGuard RA, OB500 Min. 0.25-inch SECUROCK Gypsum -Fiber Roof OB500 EverGuard TPO / TPO QSA -97.5 concrete EnergyGuard RH or EnergyGuard RN or min. 2-inch Board Insulfoam I NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 91 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8( C-153. Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or OB500 Min. 0.25-inch SECUROCK Gypsum -Fiber Roof OB500 EverGuard TPO / TPO QSA LV50 -127.5 concrete EnergyGuard RN Board Additional optional layers base insulation C-154. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, OB500 followed by min. 0.25-inch SECUROCK Gypsum- OB500 EverGuard TPO / TPO QSA LV50 -232.5 concrete EnergyGuard Ultra Fiber Roof Board C-155. Structural Min. 1.5-inch EnergyGuard RA or EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum -Fiber Roof OB500 EverGuard TPO / TPO QSA LV50 -240.0 concrete Board Min. 2-inch EnergyGuard Polyiso Insulation, C-156. Structural rgyGuard RA, EnergyGuard RH or EnergyGuard OB500 Min. 0.25-inch SECUROCK Gypsum -Fiber Roof OB500 EverGuard TPO / TPO QSA LV50 -247.5 concrete RN Board C-157. Structural Min. 1-inch EnergyGuard RH OB500 Min. 0.25-inch SECUROCK Gypsum -Fiber Roof OB500 EverGuard TPO / TPO QSA LV50 -502.5 concrete Board EverGuard TPO in FastLayn TPO Adhesive: Structural EverGuard TPO / FastLayn TPO C-158. Min. 1.5-inch EnergyGuard RA hot asphalt (Optional) Min. 0.25-inch DensDeck Prime hot asphalt -45.0 concrete Adhesive Structural Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / FastLayn TPO C-159. concrete Min. 1.5-inch thick, min. 1.25 pcf Insulfoam EPS GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part Adhesive 87 5 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Min. 0.5-inch EnergyGuard HD Polyiso EverGuard TPO / FastLayn TPO C-160. EnergyGuard Ultra Polyiso Insulation, EnergyGuard GAF 2-Part GAF 2-Part -90.0 concrete RA, or EnergyGuard RN Insulation Adhesive Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / FastLayn TPO C-161. EnergyGuard RN or Min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part -130.0 concrete Insulfoam EPS Adhesive Structural One or more layers, min. 1.5-inch thick, min. 1.5 pcf Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / FastLayn TPO C-162. concrete Insulfoam EPS GAF 2-Part Board GAF 2-Part Adhesive _180.0 Structural EverGuard TPO /FastLayn TPO C-163. Min. 0.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional) Additional layers of base insulation GAF 2-Part -232.5 concrete Adhesive Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / FastLayn TPO C-164. GAF 2-Part followed by min. 0.25-inch DensDeck Prime or GAF 2-Part -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board Adhesive Structural One or more layers, min. 1.5-inch thick, min. 2.0 pcf Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / FastLayn TPO C-165. concrete Insulfoam EPS GAF 2-Part Board GAF 2-Part Adhesive -240.0 Structural Min. 2-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / FastLayn TPO C-166. concrete EnergyGuard RN GAF 2-Part Board GAF 2-Part Adhesive 247 5 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Min. 0.5-inch EnergyGuard HD Polyiso EverGuard TPO / FastLayn TPO C-167. EnergyGuard Ultra Polyiso Insulation, EnergyGuard LRF-M LRF-M 90.0 concrete RA, or EnergyGuard RN Insulation Adhesive NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 92 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8( Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard HD Polyiso EverGuard TPO / FastLayn TPO C-168. concrete 1.5-inch EnergyGuard RH LRF-M Insulation LRF-M Adhesive -97.5 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / FastLayn TPO C-169. LRF-M followed by Min. 0.25-inch DensDeck Prime or LRF-M -232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board Adhesive Structural EverGuard TPO / FastLayn TPO C-170. Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional) Additional layers of base insulation LRF-M -292.5 concrete Adhesive Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Min. 0.5-inch EnergyGuard HD Polyiso EverGuard TPO /FastLayn TPO C-171. EnergyGuard Ultra Polyiso Insulation or EnergyGuard LRF-XF LRF-XF -90.0 concrete Insulation Adhesive Structural EverGuard TPO / FastLayn TPO C-172. Min. 1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF -130.0 concrete Adhesive Structural EverGuard TPO / FastLayn TPO C-173. Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional) Additional layers of base insulation LRF-XF -232.5 concrete Adhesive Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO /FastLayn TPO C-174. LRF-XF followed by min. 0.25-inch DensDeck Prime or LRF-XF _232.5 concrete EnergyGuard Ultra SECUROCK Gypsum -Fiber Roof Board Adhesive Structural Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / FastLayn TPO C-175. concrete Min. 2-inch EnergyGuard RA or EnergyGuard RH LRF-XF Board LRF-XF Adhesive -247.5 Structural EverGuard TPO / FastLayn TPO C-176. concrete Min. 1.5-inch Insulfoam EPS OB500 Min. 0.25-inch DensDeck Prime OB500 Adhesive -45.0 Structural EverGuard TPO / FastLayn TPO C-177. Min. 1-inch EnergyGuard RA OB500 (Optional) Additional layer of base insulation OB500 -45.0 concrete Adhesive Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / FastLayn TPO C-178. concrete EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 Adhesive _52.5 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Min. 0.5-inch EnergyGuard HD Polyiso EverGuard TPO /FastLayn TPO C-179. EnergyGuard Ultra Polyiso Insulation, EnergyGuard OB500 OBS00 90 0 concrete RA, or EnergyGuard RN Insulation Adhesive Structural Min. 0.5-inch EnergyGuard HD Polyiso EverGuard TPO / FastLayn TPO C-180. concrete Min. 1.5-inch EnergyGuard RH OB500 Insulation OB500 Adhesive 97 5 Structural EverGuard TPO / FastLayn TPO C-181. Min. 2-inch, min. 2.0 pd, Insulfoam EPS OB500 Min. 0.25-inch DensDeck Prime OB500 -120.0 concrete Adhesive Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / FastLayn TPO C-182. concrete EnergyGuard RN OB500 Board OB500 Adhesive -127.5 Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO / FastLayn TPO C-183. concrete EnergyGuard RN or Min. 1-inch Foamular 250 OB500 . . Min025-inch DensDeck Prime OB500 Adhesive -130.0 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 93 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO / FastLayn TPO C-184. concrete EnergyGuard Ultra OB500 followed by min. 0.25-inch DensDeck Prime or OB500 Adhesive -232.5 SECUROCK Gypsum -Fiber Roof Board Structural Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / FastLayn TPO C-185. Min. 1.5-inch EnergyGuard RA or EnergyGuard RN OB500 OB500 -240.0 concrete Gypsum -Fiber Roof Board Adhesive Structural Min. 2-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / FastLayn TPO C-186. concrete EnergyGuard RN OB500 Board OB500 Adhesive 247 5 Structural EverGuard TPO / FastLayn TPO C-187. Min. 0.5-inch EnergyGuard Polyiso Insulation OB500 (Optional) Additional layers of base insulation OB500 292 5 concrete Adhesive Structural (Optional) Min. 1.5-inch EnergyGuard Polyiso Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / FastLayn TPO C-188. Insulation, EnergyGuard Ultra Polyiso Insulation or OB500 Board or min. 0.5-inch EnergyGuard HD Polyiso OB500 -270.0 concrete EnergyGuard RA Insulation Adhesive Structural Min. 1.5-inch EnergyGuard Polyiso Insulation or EverGuard TPO / FastLayn TPO C-189. concrete EnergyGuard RA OB500 None N/A Adhesive -375.0 Triposite Roofing System: Structural Min. 2-inch EnergyGuard Polyiso Insulation or C-190. concrete EnergyGuard Ultra or min. 1.5-inch EnergyGuard RA, Hot Asphalt (Optional) Additional layers of base insulation Hot asphalt Triposite System. Note 15C -172.5 (primed) EnergyGuard RN EverGuard TPO Fleece -Back Membrane in Hot Asphalt: Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EverGuard TPO Fleece -Back C-191. concrete EnergyGuard RN or EnergyGuard Ultra Hot Asphalt Min. 0.25-inch DensDeck Hot asphalt Membrane /Hot asphalt -45.0 (primed) Structural C-192. concrete Min. 1-inch EnergyGuard RH Hot asphalt None N/A EverGuard TPO Fleece -Back -470.0 Membrane / Hot asphalt (primed) Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EverGuard TPO Fleece -Back C-193. concrete EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck OB500 Membrane / Hot asphalt -45.0 EverGuard TPO Fleece -Back Membrane in EverGuard WB181 Bonding Adhesive: Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece -Back C-194. concrete EnergyGuard Ultra GAF 2-Part followed by min. 0.25-inch DensDeck Prime or GAF 2-Part Membrane / WB181 -232.5 SECUROCK Gypsum -Fiber Roof Board Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO Fleece -Back C-195. concrete 1.5-inch EnergyGuard RH LRF-M Insulation, EnergyGuard HD Polyiso Insulation, LRF-M Membrane / WB181 -97.5 EnergyGuard HD Plus Polyiso Insulation Additional optional layers base insulation C-196. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-M followed by min. inch DensDeck Prime or LRF-M EverGuard TPO Fleece -Back -232.5 concrete EnergyGuard Ultra Membrane / WB181 SECUROCK Gypsum -Fiber Roof Board NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 94 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8( Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece -Back C-197. concrete EnergyGuard Ultra LRF-M (Optional) Additional layers of base insulation LRF-M Membrane/ WB181 -292.5 Additional optional layers base insulation C-198. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-XF followed by min. 0.25-inch DensDeck Prime or LRF-XF EverGuard TPO Fleece -Back -232.5 concrete EnergyGuard Ultra Membrane/WB181 SECUROCK Gypsum -Fiber Roof Board Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO Fleece -Back C-199. concrete EnergyGuard RN OB500 (Optional) Additional layer of base insulation OB500 Membrane/ WB181 _37.5 Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back C-200. concrete EnergyGuard RN OB500 Gypsum -Fiber Roof Board OB500 Membrane / WB181 -37.5 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. Min. 0.5-inch EnergyGuard RH HD Polyiso EverGuard TPO Fleece -Back C-201. concrete 1.5-inch EnergyGuard RH OB500 Insulation, EnergyGuard HD Polyiso Insulation, OB500 Membrane / WB181 -37.5 EnergyGuard HD Plus Polyiso Insulation Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back C-202. concrete EnergyGuard RN OB500 Gypsum -Fiber Roof Board OB500 Membrane/WB181 -52.5 Min. 0.5-inch EnergyGuard RH HD Polyiso Structural Min. 0.5-inch EnergyGuard Polyiso Insulation or min. EverGuard TPO Fleece -Back C-203. concrete 1.5-inch EnergyGuard RH OB500 Insulation, EnergyGuard HD Polyiso Insulation, OB500 Membrane / WB181 -97.5 EnergyGuard HD Plus Polyiso Insulation C 204 Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH or OB500 (Optional) Additional layer of base insulation OB500 EverGuard TPO Fleece -Back -127.5 concrete EnergyGuard RN Membrane/ WB181 Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO Fleece -Back C-205. concrete EnergyGuard RN OB500 (Optional) Additional layers base insulation OB500 Membrane/ WB181 -225.0 Additional optional layers base insulation C-206. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, OB500 followed by min. 0.25-inch DensDeck Prime or OB500 EverGuard TPO Fleece -Back -232.5 concrete EnergyGuard Ultra Membrane/WB181 SECUROCK Gypsum -Fiber Roof Board Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back C-207. concrete EnergyGuard RN OB500 Gypsum -Fiber Roof Board OB500 I Membrane / WB181 -240.0 C-208. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, OB500 (Optional) Additional layers of base insulation OB500 EverGuard TPO Fleece -Back 292 5 concrete EnergyGuard Ultra Membrane/ WB181 EverGuard TPO Fleece -Back Membrane in LRF Adhesive M or LRF Adhesive O: Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece -Back C-209. concrete EnergyGuard Ultra GAF 2-Part followed by min. 0.25-inch DensDeck Prime GAF 2-Part Membrane / LRF-M, 12-inch o.c. -37.5 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece -Back C-210. concrete EnergyGuard Ultra GAF 2-Part followed by min. 0.25-inch DensDeck Prime GAF 2-Part Membrane / LRF-0, 12-inch o.c. -45.0 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece -Back C-211. GAF 2-Part followed by min. 0.25-inch SECUROCK Gypsum- GAF 2-Part Membrane / LRF-M or LRF-0, 12- -45.0 concrete EnergyGuard Ultra Fiber Roof Board inch o.c. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 95 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,81 EverGuard TPO Fleece -Back C-212. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional) Additional layers base insulation GAF 2-Part Membrane / LRF-M or LRF-O, 12- -60.0 concrete EnergyGuard Ultra inch o.c. Min. 0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece -Back C-213. Structural EnergyGuard Ultra, EnergyGuard RH, EnergyGuard GAF 2-Part followed by min. 0.25-inch DensDeck Prime or GAF 2-Part Membrane / LRF-M or LRF-O, 4- -180.0 concrete RN I SECUROCK Gypsum -Fiber Roof Board inch o.c. Structural Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back C-214. GAF 2-Part None N/A Membrane /LRF-M or LRF-O, 4- -195.0 concrete Gypsum -Fiber Roof Board inch o.c. C-215. Structural (Optional) Min. 1-inch EnergyGuard RA LRF-M Min. 1.75-inch ACFoam Composite/GB LRF-M EverGuard TPO Fleece -Back -37.5 concrete Membrane / LRF-M, 12-inch o.c. EverGuard TPO Fleece -Back C-216. Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH, LRF-M Min. 0.25-inch Temple Green Glass Primed LRF-M Membrane /LRF-M or LRF-O, 12- -37.5 concrete EnergyGuard RN Roof Board inch o.c. Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH. EverGuard TPO Fleece -Back C-217. concrete EnergyGuard RN LRF-M Min. 0.25-inch DensDeck Prime LRF-M Membrane / LRF-M, 12-inch o.c. -37.5 Additional optional layers base insulation C-218. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-M followed by LRF-M EverGuard TPO Fleece -Back -37.5 concrete EnergyGuard Ultra Membrane/ LRF-M, 12-inch o.c. Min. 0.25-inch DensDeck Prime EverGuard TPO Fleece -Back C-219. Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or LRF-M (Optional) Additional layers base insulation LRF-M Membrane / LRF-M or LRF-O, 12- -45.0 concrete EnergyGuard RN inch o.c. C-220. Structural (Optional) Min. 1-inch EnergyGuard RA LRF-M Min. 1.75-inch ACFoam Composite/GB LRF-M EverGuard TPO Fleece -Back -45.0 concrete Membrane / LRF-O, 12-inch o.c. Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH. EverGuard TPO Fleece -Back C-221. concrete EnergyGuard RN LRF-M Min. 0.25-inch DensDeck Prime LRF-M Membrane / LRF-O, 12-inch o.c. -45.0 Additional optional layers base insulation C-222. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-M followed by LRF-M EverGuard TPO Fleece -Back -45.0 concrete EnergyGuard Ultra Membrane / LRF-0, 12-inch o.c. Min. 0.25-inch DensDeck Prime Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH. Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO Fleece -Back C-223. LRF-M LRF-M Membrane/ LRF-M or LRF-0, 12- -45.0 concrete EnergyGuard RN Board inch o.c. Additional optional layers base insulation Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, followed by EverGuard TPO Fleece -Back C-224. concrete EnergyGuard Ultra LRF-M Min. 0.25-inch SECUROCK Gypsum -Fiber Roof LRF-M Membrane /LRF-M or LRF-O, 12- inch o.c. -45.0 Board NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 96 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8) EverGuard TPO Fleece -Back C-225. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-M (Optional) Additional layers base insulation LRF-M Membrane / LRF-M or LRF-O, 12- -60.0 concrete EnergyGuard Ultra inch o.c. Structural Min. 1.5-inch EnergyGuard Polyiso Insulation, Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back C-226. concrete EnergyGuard RN, EnergyGuard RM LRF-M Gypsum -Fiber Roof Board LRF-M Membrane / LRF-M, 12-inch o.c. -67.5 Min. 0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece -Back C-227. Structural EnergyGuard Ultra, EnergyGuard RH, EnergyGuard LRF-M followed by min. 0.25-inch DensDeck Prime or LRF-M Membrane / LRF-M or LRF-O, 4- -180.0 concrete RN SECUROCK Gypsum -Fiber Roof Board inch o.c. EverGuard TPO Fleece -Back C-228. Structural Min. 0.25-inch DensDeck Prime or SECUROCK LRF-M None N/A Membrane /LRF-M or LRF-O, 4- -195.0 concrete Gypsum -Fiber Roof Board inch o.c. Structural EverGuard TPO Fleece -Back C 229 concrete Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional) Additional layers base insulation LRF-M Membrane / LRF-M, 4-inch o.c. -210.0 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece -Back C-230. concrete EnergyGuard Ultra LRF-XF followed by min. 0.25-inch DensDeck Prime LRF-XF Membrane / LRF-M, 12-inch o.c. -37.5 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece -Back C-231. concrete EnergyGuard Ultra LRF-XF followed by min. 0.25-inch DensDeck Prime LRF-XF Membrane / LRF-O, 12-inch o.c. -45.0 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece -Back C-232. LRF-XF followed by min. 0.25-inch SECUROCK Gypsum- LRF-XF Membrane / LRF-M or LRF-0, 12- -45.0 concrete EnergyGuard Ultra Fiber Roof Board inch o.c. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece -Back C-233. LRF-XF (Optional) Additional layers base insulation LRF-XF Membrane / LRF-M or LRF-0, 12- -60.0 concrete EnergyGuard Ultra inch o.c. Optional additional layers base insulation EverGuard TPO Fleece -Back C-234. Structural ns ns Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-XF followed by min. 0.25-inch DensDeck Prime or LRF-XF Membrane / LRF-M or LRF-0, 4- -180.0 concrete EnergyGuard Ultra or EnergyGuard SECUROCK Gypsum -Fiber Roof Board inch o.c. EverGuard TPO Fleece -Back C-235. Structural Min. 0.25-inch DensDeck Prime or SECUROCK LRF-XF None N/A Membrane /LRF-M or LRF-O, 4- -195.0 concrete Gypsum -Fiber Roof Board inch o.c. C-236. Structural (Optional) Min. 1-inch EnergyGuard RA OBS00 Min. 1.75-inch ACFoam Composite/GB OBS00 EverGuard TPO Fleece -Back -37.5 concrete Membrane / LRF-M, 12-inch o.c. EverGuard TPO Fleece -Back C-237. Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH, OB500 Min. 0.25-inch Temple Green Glass Primed OB500 Membrane / LRF-M or LRF-O, 12- -37.5 concrete EnergyGuard RN Roof Board inch o.c. Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH. EverGuard TPO Fleece -Back C 238 concrete EnergyGuard RN OBS00 Min. 0.25-inch DensDeck Prime 0B500 Membrane / LRF-M, 12-inch o.c. -37.5 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 97 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,8) Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece -Back C-239. concrete EnergyGuard Ultra OB500 followed by min. 0.25-inch DensDeck Prime OB500 Membrane / LRF-M, 12-inch o.c. -37.5 Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back C-240. concrete EnergyGuard RN OB500 Gypsum -Fiber Roof Board OB500 Membrane / LRF-0, 12-inch o.c. -37.5 Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EverGuard TPO Fleece -Back C-241. OB500 (Optional) Additional layers base insulation OB500 Membrane / LRF-M or LRF-O, 12- -45.0 concrete EnergyGuard RN inch o.c. C-242. Structural (Optional) Min. 1-inch EnergyGuard RA OB500 Min. 1.75-inch ACFoam Composite/GB OB500 EverGuard TPO Fleece -Back -45.0 concrete Membrane / LRF-0, 12-inch o.c. Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH. EverGuard TPO Fleece -Back C-243. concrete EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 Membrane / LRF-0, 12-inch o.c. -45.0 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Additional optional layers base insulation EverGuard TPO Fleece -Back C 244. concrete EnergyGuard Ultra OB500 followed by min. 0.25-inch DensDeck Prime OB500 Membrane / LRF-O, 12-inch o.c. -45.0 Structural Min. 1-inch EnergyGuard RA, EnergyGuard RH. Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO Fleece -Back C-245. OB500 OB500 Membrane / LRF-M or LRF-0, 12- -45.0 concrete EnergyGuard RN Board inch o.c. Additional optional layers base insulation EverGuard TPO Fleece -Back C-246. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, OB500 followed by min. 0.25-inch SECUROCK Gypsum- OB500 Membrane / LRF-M or LRF-0, 12- -45.0 concrete EnergyGuard Ultra Fiber Roof Board inch o.c. Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EverGuard TPO Fleece -Back C 247 concrete I EnergyGuard RN OB500 (Optional) Additional layer of base insulation OB500 Membrane / LRF-0, 12-inch o.c. -45.0 Structural Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back C-248. concrete EnergyGuard RN OB500 Gypsum -Fiber Roof Board OB500 Membrane / LRF-0, 12-inch o.c. -45.0 Structural Min. 1.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece -Back C-249. concrete EnergyGuard Ultra OB500 (Optional) Additional layer of base insulation OB500 Membrane / LRF-0, 12-inch o.c. -60.0 Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece -Back C-250. OB500 (Optional) Additional layers base insulation OB500 Membrane / LRF-M or LRF-O, 12- -60.0 concrete EnergyGuard Ultra inch o.c. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece -Back C-251. EnergyGuard Ultra, EnergyGuard RH, EnergyGuard OB500 followed by min. 0.25-inch DensDeck Prime or OB500 Membrane / LRF-M or LRF-O, 4- -180.0 concrete RN SECUROCK Gypsum -Fiber Roof Board inch o.c. EverGuard TPO Fleece -Back C-252. Structural Min. 0.25-inch DensDeck Prime or SECUROCK OB500 None N/A Membrane /LRF-M or LRF-0, 4- -195.0 concrete Gypsum -Fiber Roof Board inch o.c. EverGuard TPO Fleece -Back Membrane in Spatter Applications: NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization H32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 98 of 156 NNEMO I etc. TABLE 3A: STRUCTURAL CONCRETE DECKS TYPE A-1: BONDED - NEW CONSTRUCTION OR .. (TEAR -OFF) INSULATION, BONDED ROOF COVER REFER To NOTE 16 Base Insulation Layer OPTIONSSYSTEM FOR VAPOR BARRIER Top Insulation Layer System Deck Attach Roof Cover (Note 15) MDP Attach No. (Note 1) Type Type (Psfl (Notes 6,7,8) (Notes 6,7,81 EverGuard TPO Fleece -Back C-253. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional) Additional layers base insulation GAF 2-Part Membrane/GAF 2-Part (spatter), -180.0 concrete EnergyGuard Ultra LRF-XF (spatter) or OBS00 (spatter) Min. 0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece -Back C-254. Structural EnergyGuard Ultra, EnergyGuard RH, EnergyGuard GAF 2-Part followed by min. 0.25-inch DensDeck Prime or GAF 2-Part Membrane / GAF 2-Part (spatter), -180.0 concrete RN I SECUROCK Gypsum -Fiber Roof Board LRF-XF (spatter) or OB500 (spatter) Structural Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back C-255. GAF 2-Part None N/A Membrane / GAF 2-Part (spatter), -195.0 concrete Gypsum -Fiber Roof Board LRF-XF (spatter) or OB500 (spatter) Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece -Back C-256. LRF-M (Optional) Additional layers base insulation LRF-M Membrane / GAF 2-Part (spatter), -180.0 concrete EnergyGuard Ultra LRF-XF (spatter) or OB500 (spatter) Min. 0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece -Back C-257. Structural EnergyGuard Ultra, EnergyGuard RH, EnergyGuard LRF-M followed by min. 0.25-inch DensDeck Prime or LRF-M Membrane/GAF 2-Part (spatter), -180.0 concrete RN SECUROCK Gypsum -Fiber Roof Board LRF-XF (spatter) or OBS00 (spatter) EverGuard TPO Fleece -Back C-258. Structural Min. 0.25-inch DensDeck Prime or SECUROCK LRF-M None N/A Membrane / GAF 2-Part (spatter), -195.0 concrete Gypsum -Fiber Roof Board LRF-XF (spatter) or OBS00 (spatter) EverGuard TPO Fleece -Back C-259. Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional) Additional layers base insulation LRF-XF Membrane / GAF 2-Part (spatter), -180.0 concrete EnergyGuard Ultra LRF-XF (spatter) or OB500 (spatter) Optional additional layers base insulation EverGuard TPO Fleece -Back C-260. Structural Insulation, Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-XF followed by min. 0.25-inch DensDeck Prime or LRF-XF Membrane / GAF 2-Part (spatter), -180.0 concrete EnergyGuard Ultra or EnergyGuard SECUROCK Gypsum -Fiber Roof Board LRF-XF (spatter) or OB500 (spatter) Structural Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO Fleece -Back C-261. LRF-XF None N/A Membrane / GAF 2-Part (spatter), -195.0 concrete Gypsum -Fiber Roof Board LRF-XF (spatter) or OB500 (spatter) Structural Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece -Back C-262. 0B500 (Optional) Additional layers base insulation OBS00 Membrane / GAF 2-Part (spatter), -180.0 concrete EnergyGuard Ultra LRF-XF (spatter) or OB500 (spatter) Min. 0.5-inch EnergyGuard Polyiso Insulation, Optional additional layers base insulation EverGuard TPO Fleece -Back C-263. Structural EnergyGuard Ultra, EnergyGuard RH, EnergyGuard OB500 followed by min. 0.25-inch DensDeck Prime or OB500 Membrane/GAF 2-Part (spatter), -180.0 concrete RN SECUROCK Gypsum -Fiber Roof Board LRF-XF (spatter) or OBS00 (spatter) EverGuard TPO Fleece -Back C 264. Structural Min. 0.25-inch DensDeck Prime or SECUROCK OB500 None N/A Membrane / GAF 2-Part (spatter), -195.0 concrete Gypsum -Fiber Roof Board LRF-XF (spatter) or OBS00 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization H32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 99 of 156 NNEMO I etc. TABLE 313: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR .. R- SYSTEM TYPE A-1: BONDED INSULATION, BONDED BASE AND CAP PLY REFER To NOTE 16 FOR VAPOR BARRIER .. Base Insulation Layer777- Top Insulation Layer Roof Cover (Note 15) System No. Deck (Note 1) Type Attach Type Attach Base Ply MDP Cap Ply (psf) 7 (Notes 6,7,8) (Notes 6,7,8) Asphalt -Applied Base Ply: Structural EnergyGuard Polyiso Insulation, GAF 2-Part, Min. 0.25-inch SECUROCK GAF 2-Part, Ruberoid 20 Smooth EverGuard TPO Fleece -Back Membrane C-265. concrete EnergyGuard RH, EnergyGuard RM or LRF-M or Gypsum -Fiber Roof Board LRF-M or hot asphalt /LRF-O, 12-inch o.c. -60.0 EnergyGuard RN OB500 OB500 EnergyGuard Polyiso Insulation, GAF 2-Part, GAF 2-Part, EverGuard TPO Fleece -Back Membrane Structural Min. 0.25-inch SECUROCK Ruberoid 20 Smooth / hot asphalt, GAF 2-Part (spatter), LRF- C-266. concrete EnergyGuard RH, EnergyGuard RM or LRF-M or Gypsum -Fiber Roof Board LRF-M or / hot asphalt XF (spatter) or OB500 (spatter) or LRF- -180.0 EnergyGuard RN OB500 OB500 0, 4-inch o.c. Structural EnergyGuard Polyiso Insulation or Min. 0.25-inch SECUROCK Ruberoid 20 Smooth EverGuard TPO Fleece -Back Membrane C-267. concrete EnergyGuard RH LRF-XF Gypsum -Fiber Roof Board LRF-XF / hot asphalt / LRF-O, 12-inch o.c. -60.0 EverGuard TPO Fleece -Back Membrane / hot asphalt, GAF 2-Part (spatter) or C-268. Structural EnergyGuard Polyiso Insulation or LRF-XF Min. 0.25-inch SECUROCK LRF-XF Ruberoid 20 Smooth OB500 (spatter)GAF 2-Part (spatter), -180.0 concrete EnergyGuard RH Gypsum -Fiber Roof Board hot asphalt LRF-XF (spatter) or OB500 (spatter) or LRF-O, 4-inch o.c. Torch -Applied Base Ply: EnergyGuard Polyiso Insulation, GAF 2-Part, GAF 2-Part, Ruberoid HW 25 C-269. Structural EnergyGuard RH, EnergyGuard RM or LRF-M or Min. LRF-M or Smooth / torch- EverGuard TPO Fleece -Back Membrane -60.0 concrete um -Finch Roof Board Gypsum -Fiber Roof Board /LRF-O, 12-inch o.c. EnergyGuard RN OB500 OB500 applied EverGuard TPO Fleece -Back Membrane Structural EnergyGuard Polyiso Insulation, GAF 2-Part, Min. 0.25-inch SECUROCK GAF 2-Part, Ruberoid HW 25 / hot asphalt, GAF 2-Part (spatter), LRF- C-270. EnergyGuard RH, EnergyGuard RM or LRF-M or LRF-M or Smooth /torch- -180.0 concrete EnergyGuard RN OB500 Gypsum -Fiber Roof Board OB500 applied XF (spatter) or OB500 (spatter) or LRF- 0, 4-inch o.c. Ruberoid HW 25 C-271. Structural EnergyGuard Polyiso Insulation or LRF-XF Min. 0.25-inch SECUROCK LRF-XF Smooth / torch- EverGuard TPO Fleece -Back Membrane -60.0 concrete EnergyGuard RH Gypsum -Fiber Roof Board / LRF-O, 12-inch o.c. applied EverGuard TPO Fleece -Back Membrane Structural EnergyGuard Polyiso Insulation or Min. 0.25-inch SECUROCK Ruberoid HW 25 / hot asphalt, GAF 2-Part (spatter), LRF- C 272 concrete EnergyGuard RH LRF-XF Gypsum -Fiber Roof Board LRF-XF Smooth /torch- XF (spatter) or OB500 (spatter) or LRF- _180.0 applied O, 4-inch o.c. Self -Adhering Base Ply: EnergyGuard Polyiso Insulation, GAF 2-Part, GAF 2-Part, Liberty SBS Self- C-273. Structural EnergyGuard RH, EnergyGuard RM or LRF-M or Min. LRF-M or Adhering Cap Sheet / EverGuard TPO Fleece -Back Membrane _60.0 concrete um -Finch Roof Board Gypsum -Fiber Roof Board /LRF-O, 12-inch o.c. EnergyGuard RN OB500 OB500 self -adhered NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 100 of 156 NNEMO I etc. TABLE 313: STRUCTURAL CONCRETE SYSTEM TYPE A-1: DECKS - NEW CONSTRUCTION OR BONDED INSULATION, BONDED BASE .. R- Base Insulation Layer System Deck OPTIONSREFER To NOTE 16 FOR VAPOR BARRIER Top Insulation Layer Roof Cover (Note 15) MDP No. (Note 1) Type Attach Type Attach Base Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) EverGuard TPO Fleece -Back Membrane Structural EnergyGuard Polyiso Insulation, GAF 2-Part, Min. 0.25-inch SECUROCK GAF 2-Part, Liberty SBS Self- / hot asphalt, GAF 2-Part (spatter), LRF- C-274. EnergyGuard RH, EnergyGuard RM or LRF-M or LRF-M or Adhering Cap Sheet / -180.0 concrete EnergyGuard RN OB500 Gypsum -Fiber Roof Board OB500 self -adhered XF (spatter) or OB500 (spatter) or LRF- O, 4-inch o.c. Structural EnergyGuard Polyiso Insulation or Min. 0.25-inch SECUROCK Liberty SBS Self- EverGuard TPO Fleece -Back Membrane C-275. concrete EnergyGuard RH LRF-XF Gypsum -Fiber Roof Board LRF-XF Adhering Cap Sheet / / LRF-O, 12-inch o.c. _60.0 self -adhered EverGuard TPO Fleece -Back Membrane Structural EnergyGuard Polyiso Insulation or Min. 0.25-inch SECUROCK Liberty SBS Self- / hot asphalt, GAF 2-Part (spatter), LRF- C-276. LRF-XF LRF-XF Adhering Cap Sheet / -180.0 concrete EnergyGuard RH Gypsum -Fiber Roof Board self -adhered XF (spatter) or OB500 (spatter) or LRF- O, 4-inch o.c. System No. CONCRETETABLE 3c: STRUCTURAL rECKS - SYSTEM TYPE F: • Deck (Note 1) NEW CONSTRUCTION OR REROOF r BONDED Roof Cover (Note 15) MOP (psf) C-277. Min. 2,500 psi structural concrete EverGuard TPO Fleece -Back Membrane / LRF-M or LRF-O, 12-inch o.c. -60.0 C-278. Min. 2,500 psi structural concrete EverGuard TPO Fleece -Back Membrane / WB181 -300.0 C-279. Min. 3,000 psi structural concrete primed with MatrixT" 307 Premium Asphalt Primer. EverGuard TPO Fleece -Back Membrane / Hot asphalt -390.0 C-280. Min. 2,500 psi structural concrete EverGuard TPO Fleece -Back Membrane / OB500 (spatter) -435.0 C-281. Min. 2,500 psi structural concrete EverGuard TPO Fleece -Back Membrane / GAF 2-Part (spatter) -497.5 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMo ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 101 of 156 NNEMO I etc. BILE 4A: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR .. R- .DECK, BONDED INSULATION, BONDED ROOF Base Insulation Layer Coverboard System Deck Lightweight Concrete MDP No. (Note 1) (Note 14) Type Attach Type Attach Roof Cover (Note 15) (psf) (Notes 6,7,8) (Notes 6,7,8) CELCORE(FL2O37): EverGuard Freedom TPO: Structural Min. 200 psi, min. 2-inch thick Celcore Cellular Min. 1.5-inch EnergyGuard RA, Min. 0.25-inch SECUROCK EverGuard Freedom LWC-1. concrete Concrete EnergyGuard RH or EnergyGuard RN GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part TPO / self adhered 222.5 EverGuard TPO / EverGuard TPO #1121 Bonding Adhesive or EVERUGARD TPO 3 SQUARE LOW VOC BONDING ADHESIVE: Min. 0.25-inch DensDeck, Structural Min. 200 psi, min. 2-inch thick Celcore Cellular Min. 1.5-inch thick, min. 1.25 pcf density DensDeck Prime or EverGuard TPO / LWC-2. concrete Concrete Insulfoam EPS or STYROFOAM Brand XPS GAF 2-Part SECUROCK Gypsum Fiber GAF 2-Part #1121, TPO 3-Square 87 5 Roof Board (Optional) Min. 1.5-inch EnergyGuard Structural Min. 200 psi, min. 2-inch thick Celcore Cellular RA, EnergyGuard RH or EnergyGuard RN Min. 0.25-inch DensDeck EverGuard TPO / LWC-3. or Min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part GAF 2-Part -130.0 concrete Concrete density Insulfoam EPS or STYROFOAM or DensDeck Prime #1121, TPO 3-Square Brand XPS Structural Min. 200 psi, min. 2-inch thick Celcore Cellular Min. 1.5-inch EnergyGuard Polyiso (Optional) Additional layer EverGuard TPO / LWC-4. concrete Concrete Insulation, EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part #1121, TPO 3-Square 222 5 (Optional) Min. 1.5-inch EnergyGuard Structural Min. 200 psi, min. 2-inch thick Celcore Cellular RA, EnergyGuard RH or EnergyGuard RN Min. 0.25-inch SECUROCK EverGuard TPO / LWC-5. or Min. 1.5-inch thick, min. 2.0 pcf GAF 2-Part GAF 2-Part 222.5 concrete Concrete density Insulfoam EPS or STYROFOAM Gypsum -Fiber Roof Board #1121, TPO 3-Square Brand XPS EverGuard TPO / EverGuard WB181 Bonding Adhesive: Structural Min. 200 psi, min. 2-inch thick Celcore Cellular Min. 1.5-inch thick, min. 1.25 pcf density Min. 0.25-inch DensDeck EverGuard TPO / LWC-6. concrete Concrete Insulfoam EPS or STYROFOAM Brand XPS GAF 2-Part Prime GAF 2-Part WB181 87 5 (Optional) Min. 1.5-inch EnergyGuard Structural Min. 200 psi, min. 2-inch thick Celcore Cellular RA, EnergyGuard RH or EnergyGuard RNor Min. 0.25-inch DensDeck EverGuard TPO / LWC-7. Min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part GAF 2-Part -130.0 concrete Concrete density Insulfoam EPS or STYROFOAM Prime W8181 Brand XPS Structural Min. 200 psi, min. 2-inch thick Celcore Cellular Min. 1.5-inch EnergyGuard Polyiso (Optional) Additional layer EverGuard TPO / LWC-8. concrete Concrete Insulation, EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part WB181 222 5 EverGuard TPO / EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: (Optional) Min. 1.5-inch EnergyGuard Min. 0.25-inch DensDeck EverGuard TPO TPO l Min. 200 psi, min. 2-inch thick Celcore Cellular RA, EnergyGuard RH or EnergyGuard RN, =LWC_��concretre Concrete min. 1.5-inch thick, min. 1.25 pcf density GAF 2-Part Prime or SECUROCK GAF 2-Part 6-Square, TPO 3- -45.0 Gypsum -Fiber Roof Board Square Insulfoam EPS or STYROFOAM Brand XPS NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 102 of 156 NNEMO I etc. TABLE 4A: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR .. R- I SYSTEM TYPE A-1: LWC TO DECK, BONDED INSULATION, BONDED Base Insulation Layer ROOF COVER Coverboard System Deck Lightweight Concrete MDP Type Attach No. (Note 1) (Note 14) Type Attach Roof Cover (Note 15) jpsf► (Notes 6,7,8) (Notes 6,7,8) EverGuard TPO Structural Min. 200 psi, min. 2-inch thick Celcore Cellular Min. 1.5-inch EnergyGuard Polyiso (Optional) Additional layer LWC-10. concrete Concrete Insulation, EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part 6-Square, TPPOO 3---222.5 Square ELASTIZELL (FL4994): EverGuard Freedom TPO: Structural Min. 200 psi, min. 2-inch thick Elastizell Range II Min. 1.5-inch EnergyGuard RA, Min. 0.25-inch SECUROCK EverGuard Freedom LWC-11. concrete LWC EnergyGuard RH or EnergyGuard RN GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part TPO / self adhered _180.0 Structural Min. 200 psi, min. 2-inch thick Elastizell Range II Min. 1.5-inch EnergyGuard Polyiso (Optional) Additional layer EverGuard Freedom LWC-12. concrete LWC Insulation, EnergyGuard Ultra OB500 of base insulation OB500 TPO / self adhered -142.5 Structural Min. 200 psi, min. 2-inch thick Elastizell Range II (Optional) Min. 1.5-inch EnergyGuard Min. 0.25-inch SECUROCK EverGuard Freedom LWC-13. concrete LWC RA, EnergyGuard RH or EnergyGuard RN OB500 Gypsum -Fiber Roof Board OB500 TPO / self adhered -225.0 EverGuard TPO / EverGuard TPO #1121 Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Min. 0.25-inch DensDeck, Structural Min. 200 psi, min. 2-inch thick Elastizell Range II Min. 1.5-inch thick, min. 1.25 pcf density DensDeck Prime or EverGuard TPO / LWC-14. concrete LWC Insulfoam EPS or STYROFOAM Brand XPS GAF 2-Part SECUROCK Gypsum -Fiber GAF 2-Part #1121, TPO 3-Square 87 5 Roof Board (Optional) Min. 1.5-inch EnergyGuard Structural Min. 200 psi, min. 2-inch thick Elastizell Range II RA, EnergyGuard RH or EnergyGuard RN Min. inch DensDeck EverGuard / LWC-15. or Min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part GAF 2-Part -130.0 concrete LWC density Insulfoam EPS or STYROFOAM or DensDeck Prime 3-Sck #1121, TPO 3-Square Brand XPS (Optional) Min. 1.5-inch EnergyGuard Structural Min. 200 psi, min. 2-inch thick Elastizell Range II RA, EnergyGuard RH or EnergyGuard RN Min. 0.25-inch SECUROCK EverGuard TPO / LWC-16. or Min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part GAF 2-Part -180.0 concrete LWC density Insulfoam EPS or STYROFOAM Gypsum -Fiber Roof Board #1121, TPO 3-Square Brand XPS Min. 0.25-inch DensDeck, Structural Min. 200 psi, min. 2-inch thick Elastizell Range II DensDeck Prime or EverGuard TPO / LWC-17. Min. 2-inch, min. 2.0 pcf, Insulfoam EPS OB500 OB500 -120.0 concrete LWC SECUROCK Gypsum -Fiber #1121, TPO 3-Square Roof Board Structural Min. 200 psi, min. 2-inch thick Elastizell Range II (Optional) Min. 1.5-inch EnergyGuard Min. 0.25-inch DensDeck EverGuard TPO / LWC-18. concrete LWC RA, EnergyGuard RH or EnergyGuard RN OB500 or DensDeck Prime OB500 #1121, TPO 3-Square -130.0 Structural Min. 200 psi, min. 2-inch thick Elastizell Range II Min. 1.5-inch EnergyGuard Polyiso (Optional) Additional layer EverGuard TPO / LWC-19. concrete LWC Insulation, EnergyGuard Ultra OB500 of base insulation OB500 #1121, TPO 3-Square -180.0 Structural Min. 200 psi, min. 2-inch thick Elastizell Range II (Optional) Min. 1.5-inch EnergyGuard Min. 0.25-inch SECUROCK EverGuard TPO / LWC-20. concrete LWC RA, EnergyGuard RH or EnergyGuard RN OB500 Gypsum -Fiber Roof Board OB500 #1121, TPO 3-Square -180.0 EverGuard TPO / EverGuard WB181 Bonding Adhesive: lm NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 103 of 156 NNEMO I etc. TABLE 4A: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR .. R- I SYSTEM TYPE A-1: LWC TO DECK, BONDED INSULATION, BONDED Base Insulation Layer ROOF COVER Coverboard System Deck Lightweight Concrete MDP Type Attach Type Attach No. (Note 1) (Note 14) Roof Cover (Note 15) jpsf► (Notes 6,7,8) (Notes 6,7,8) Structural Min. 200 psi, min. 2-inch thick Elastizell Range II Min. 1.5-inch thick, min. 1.25 pcf density Min. 0.25-inch DensDeck EverGuard TPO / LWC-21. concrete LWC Insulfoam EPS or STYROFOAM Brand XPS GAF 2-Part Prime GAF 2-Part WB181 87 5 (Optional) Min. 1.5-inch EnergyGuard Structural Min. 200 psi, min. 2-inch thick Elastizell Range II RA, EnergyGuard RH or EnergyGuard RN Min. 0.25-inch DensDeck EverGuard TPO / LWC-22. or Min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part GAF 2-Part -130.0 concrete LWC density Insulfoam EPS or STYROFOAM Prime WB181 Brand XPS Structural Min. 200 psi, min. 2-inch thick Elastizell Range II Min. 1.5-inch EnergyGuard Polyiso (Optional) Additional layer EverGuard TPO / LWC-23. concrete LWC Insulation, EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part WB181 -180.0 Structural Min. 200 psi, min. 2-inch thick Elastizell Range II Min. 0.25-inch DensDeck EverGuard TPO / LWC-24. Min. 2-inch, min. 2.0 pcf, Insulfoam EPS OB500 OB500 -120.0 concrete LWC Prime WB181 Structural Min. 200 psi, min. 2-inch thick Elastizell Range II (Optional) Min. 1.5-inch EnergyGuard Min. 0.25-inch DensDeck EverGuard TPO / LWC-25. concrete LWC RA, EnergyGuard RH or EnergyGuard RN OB500 Prime OB500 WB181 -130.0 Structural Min. 200 psi, min. 2-inch thick Elastizell Range II Min. 1.5-inch EnergyGuard Polyiso (Optional) Additional layer EverGuard TPO / LWC-26. concrete LWC Insulation, EnergyGuard Ultra OB500 of base insulation OB500 W8181 -180.0 EverGuard TPO / EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: (Optional) Min. 1.5-inch EnergyGuard Min. 0.25-inch DensDeck EverGuard TPO TPO Structural Min. 200 psi, min. 2-inch thick Elastizell Range II RA, EnergyGuard RH or EnergyGuard RN, LWC-27. concrete LWC min. 1.5-inch thick, min. 1.25 pcf density GAF 2-Part Prime or SECUROCK GAF 2-Part TPO 3- -45.0 Gypsum -Fiber Roof Board Squarere, Square Insulfoam EPS or STYROFOAM Brand XPS EverGuard Structural Min. 200 psi, min. 2-inch thick Elastizell Range II Min. 1.5-inch EnergyGuard Polyiso (Optional) Additional layer LWC-28. concrete LWC Insulation, EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part PO -TPO TPO 3- -180.0 Squarere, Square (Optional) Min. 1.5-inch EnergyGuard Min. 0.25-inch DensDeck EverGuard TPO / TPO LWC-29. Structural . . Min200 psi, min2-inch thick Elastizell Range II RA, EnergyGuard RH or EnergyGuard RN, OB500 Prime or SECUROCK OB500 6-Square, TPO 3- -45.0 concrete LWC min. 2-inch, min. 2.0 pcf, Insulfoam EPS Gypsum -Fiber Roof Board Square MEARLCRETE (FL13492): EverGuard Freedom TPO: Structural Min. 1.5-inch EnergyGuard RA, Min. 0.25-inch SECUROCK EverGuard Freedom LWC-30. concrete Min. 200 psi, min. 2-inch thick Mearlcrete EnergyGuard RH or EnergyGuard RN GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part TPO / self adhered -240.0 LWC-31. Structural Min. 250 psi, min. 2-inch Mearlcrete Min. 0.25-inch SECUROCK Gypsum -Fiber OB500 None N/A EverGuard Freedom 75 0 concrete Roof Board TPO / self adhered EverGuard TPO / EverGuard TPO #1121 Bonding Adhesive or EVERUGARD TPO 3 SQUARE LOW VOC BONDING ADHESIVE: MAI Min. 0.25-inch DensDeck, Structural Min. 1.5-inch thick, min. 1.25 pcf density DensDeck Prime or EverGuard TPO / LWC-32. concrete Min. 200 psi, min. 2-inch thick Mearlcrete Insulfoam EPS or STYROFOAM Brand XPS GAF 2-Part SECUROCK Gypsum -Fiber GAF 2-Part #1121, TPO 3-Square 87 5 Roof Board NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 104 of 156 NNEMO I etc. BILE 4A: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR .. R- 7No. 7(Note I SYSTEM TYPE A-1: LWC TO DECK, BONDED INSULATION, BONDED Base Insulation Layer ROOF COVER Coverboard I Lightweight Concrete MDP Type Attach Type Attach (Note 14) Roof Cover (Note 15) 1psf1 (Notes 6,7,8) (Notes 6,7,8) (Optional) Min. 1.5-inch EnergyGuard Structural RA, EnergyGuard RH or EnergyGuard RN Min. 0.25-inch DensDeck EverGuard TPO / LWC-33. Min. 200 psi, min. 2-inch thick Mearlcrete or Min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part GAF 2-Part -130.0 concrete density Insulfoam EPS or STYROFOAM or DensDeck Prime #1121, TPO 3-Square Brand XPS (Optional) Min. 1.5-inch EnergyGuard Structural RA, EnergyGuard RH or EnergyGuard RN Min. 0.25-inch SECUROCK EverGuard TPO / LWC-34. Min. 200 psi, min. 2-inch thick Mearlcrete or Min. 1.5-inch thick, min. 2.0 pcf GAF 2-Part GAF 2-Part -240.0 concrete density Insulfoam EPS or STYROFOAM Gypsum -Fiber Roof Board #1121, TPO 3-Square Brand XPS EverGuard TPO / EverGuard WB181 Bonding Adhesive: Structural Min. 1.5-inch thick, min. 1.25 pcf density Min. 0.25-inch DensDeck EverGuard TPO / LWC-35. concrete Min. 200 psi, min. 2-inch thick Mearlcrete Insulfoam EPS or STYROFOAM Brand XPS GAF 2-Part Prime GAF 2-Part WB181 87 5 (Optional) Min. 1.5-inch EnergyGuard Structural RA, EnergyGuard RH or EnergyGuard RN Min. 0.25-inch DensDeck EverGuard TPO / LWC-36. Min. 200 psi, min. 2-inch thick Mearlcrete or Min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part GAF 2-Part -130.0 concrete density Insulfoam EPS or 5TYROFOAM Prime WB181 Brand XPS Structural Min. 1.5-inch EnergyGuard Polyiso (Optional) Additional layer EverGuard TPO / LWC-37. Min. 200 psi, min. 2-inch thick Mearlcrete GAF 2-Part GAF 2-Part -240.0 concrete Insulation, EnergyGuard Ultra I of base insulation WB181 EverGuard TPO / EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: (Optional) Min. 1.5-inch EnergyGuard Min. 0.25-inch DensDeck EverGuard TPO TPO Structural RA, EnergyGuard RH or EnergyGuard RN, LWC-38. concrete Min. 200 psi, min. 2-inch thick Mearlcrete min. 1.5-inch thick, min. 1.25 pcf density GAF 2-Part Prime or SECUROCK GAF 2-Part 6-Square, TPO 3- -45.0 Gypsum -Fiber Roof Board Square Insulfoam EPS or STYROFOAM Brand XPS EverGuard TPO / TPO Structural Min. 1.5-inch EnergyGuard Polyiso (Optional) Additional layer LWC-39. concrete Min. 200 psi, min. 2-inch thick Mearlcrete Insulation, EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part 6-Square, TPO 3- -240.0 Square PRE-EXISTENT CELLULAR LWC (NOTE 14): EverGuard TPO / EverGuard TPO #1121 Bonding Adhesive: Structural Min. 290 psi, min. 3-inch thick pre-existent cellular Min. 1-inch EnergyGuard Polyiso (Optional) Additional EverGuard TPO / LWC-40. concrete lightweight insulating concrete Insulation or EnergyGuard RH OB500 layer(s) base insulation OB500 #1121 47 5 Min. 1-inch EnergyGuard Polyiso Structural Min. 290 psi, min. 3-inch thick pre-existent cellular Insulation, EnergyGuard Ultra Polyiso Min. 0.25-inch DensDeck EverGuard TPO / LWC-41. Insulation, EnergyGuard RA, OB500 Prime or SECUROCK OB500 -67.5 concrete lightweight insulating concrete EnergyGuard RH, EnergyGuard RN or Gypsum -Fiber Roof Board #1121 EnergyGuard RM EverGuard TPO / EverGuard WB181 Bonding Adhesive: NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 105 of 156 NNEMO I etc. TABLE 4A: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR .. R- I SYSTEM TYPE A-1: LWC TO DECK, BONDED INSULATION, BONDED Base Insulation Layer ROOF COVER Coverboard System Deck Lightweight Concrete MDP Type Attach Type Attach No. (Note 1) (Note 14) Roof Cover (Note 15) jpsf► (Notes 6,7,8) (Notes 6,7,8) Structural Min. 290 psi, min. 3-inch thick pre-existent cellular Min. 1-inch EnergyGuard Polyiso (Optional) Additional EverGuard TPO / LWC-42. concrete lightweight insulating concrete Insulation OB500 layer(s) base insulation OB500 WB181 47 5 Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Min. 0.5-inch EnergyGuard Structural Min. 290 psi, min. 3-inch thick pre-existent cellular HD Polyiso Insulation or EverGuard TPO / LWC-43. concrete lightweight insulating concrete Insulation, EnergyGuard RA, OB500 EnergyGuard HD Plus OB500 WB181 -47.5 EnergyGuard RH, EnergyGuard RN or EnergyGuard RM Polyiso Insulation EverGuard TPO / EverGuard TPO 6 Square Low VOC Bonding Adhesive: Structural Min. psi, min. 3-inch thick pre-existent cellular Min. 1-inch EnergyGuard Polyiso (Optional)Additional EverGuard TPO TPOr47.5concrete LWC-44. lightweight insulating concrete ei Insulation, EnergyGuard RA or OB500 base insulation OB500 6-SquareMin. EnergyGuard RHlayer(s) 1-inch EnergyGuard Polyiso Structural Min. 290 psi, min. 3-inch thick pre-existent cellular Insulation, EnergyGuard Ultra Polyiso Min. 0.25-inch DensDeck EverGuard TPO / TPO LWC-45. Insulation, EnergyGuard RA, OB500 Prime or SECUROCK OB500 concrete lightweight insulating concrete EnergyGuard RH, EnergyGuard RN or Gypsum -Fiber Roof Board 6-Square EnergyGuard RM EverGuard TPO / EverGuard TPO Quick Spray Adhesive: Min. 400 psi, min. 2-inch thick pre-existent cellular lightweight insulating concrete; mote: To qualify the Min. 0.5-inch EnergyGuard HD Polyiso LWC-46. Structural LWIC under this assembly, a Drill-TecTM Base Sheet Insulation, EnergyGuard HD Plus Polyiso LRF-XF None N/A EverGuard TPO TPO -230.0 concrete Fastener (1. 7 in.) or Drill-Tec'" Base Sheet Fastener E(1. 7 Insulation QSA in.) shall achieve MCRF of 117 lbfor greater when tested per TA5105. Min. 400 psi, min. 2-inch thick pre-existent cellular lightweight insulating concrete; Mote: To qualify the Min. 0.5-inch EnergyGuard HD Polyiso LWC-47. Structural LWIC under this assembly, a Drill-TecTM Base Sheet Insulation, EnergyGuard HD Plus Polyiso OB500 None N/A EverGuard TPO TPO -140.0 Concrete Fastener (1.7 in.) or Drill-Tec'"Base Sheet Fastener E(1.7 Insulation ClSA in.) shall achieve MCRF of 117lbf or greater when tested per TA5105. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 106 of 156 NNEMO I etc. TABLE 4B: LIGHTWEIGHT CONCRETE OVER STEEL DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-2: LWC TO DECK, MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Lightweight Anchor Sheet Insulation Roof Cover (Note 15) System Deck MDP Concrete Fasteners Attach No. (Note 1) Type Attach Base Top Base Ply Cap Ply (psf) (Note 14) (Note 11) (Notes 6,7,8) CELCORE(FL2D37): GAFG LAS #75 Base Sheet, 9-inch o.c. at the 2- Min. 22 Minimum 300 psi, Tri-Ply #75 Base Sheet, Drill-Tec Base inch side lap and 9- Min. 1.5-inch Min. 0.25-inch EverGuard ga., type minimum 2-inch GAFGLAS #80 Ultima Base Sheet Fastener inch o.c. at two, EnergyGuard RA, SECUROCK Freedom LWC-48. BV, Grade thick Celcore Sheet or GAFGLAS (1.7 in.) or Drill- equally spaced, EnergyGuard RH, Gypsum -Fiber OB500 None TPO / Self- 45.0 33 steel Cellular Concrete Stratavent Nailable Tec Base Sheet staggered rows in the EnergyGuard RN Roof Board adhered Fastener E (1.7 in.) Venting Base Sheet center of the sheet Min. 0.25-inch DensDeck GAFGLAS #75 Base Sheet, 9-inch o.c. at the 2- Prime or EverGuard Min. 22 Minimum 300 psi, Tri-Ply #75 Base Sheet, Drill-Tec Base inch side lap and 9- Min. 1.5-inch SECUROCK TPO / Sheet Fastener Gypsum -Fiber LWC-49. ga., type minimum 2-inch GAFGLAS #80 Ultima Base (1.7 in.) or Drill- inch o.c. at two, EnergyGuard RA, Roof Board or 08500 None #1121, TPO -45.0 BV, Grade thick Celcore Sheet or GAFGLAS equally spaced, EnergyGuard RH, 6-Square, 33 steel Cellular Concrete Stratavent Nailable Tec Base Sheet staggered rows in the EnergyGuard RN min. inch 3- Fastener E (1.7 in.) StruTPO tod Venting Base Sheet center of the sheet High Density High Density n Square Fiberboard Roof Insulation GAFG LAS #75 Base Sheet, Drill-Tec Base 9-inch o.c. at the 2- Min. 0.25-inch Min. 22 Minimum 300 psi, Tri-Ply #75 Base Sheet, inch side lap and 9- Min. 1.5-inch DensDeck ga., type minimum 2-inch GAFGLAS #80 Ultima Base Sheet Fastener in.) or Drill- inch o.c. at two, EnergyGuard RA, Prime or OB500 None EverGuard TPOLWC-50. / -45.0 BV, Grade thick Celcore Sheet or GAFGLAS equally spaced, EnergyGuard RH, SECUROCK 33 steel Cellular Concrete Stratavent Nailable Tec Base Sheet Tec staggered rows in the EnergyGuard RN Gypsum -Fiber WB 181 Fastener E (1.7 in.) Venting Base Sheet center of the sheet Roof Board GAFGLAS #75 Base Sheet, 9-inch o.c. at the 2- Min. 0.25-inch Min. 22 Minimum 300 psi, Tri-Ply #75 Base Sheet, Drill-Tec Base inch side lap and 9- Min. 1.5-inch DensDeck EverGuard LWC-51. ga., type minimum 2-inch GAFGLAS #80 Ultima Base Sheet Fastener (1.7 in.) Drill- inch o.c. at two, EnergyGuard RA, Prime or 0B500 None TPO Fleece- Back -45.0 BV, Grade thick Celcore Sheet or GAFGLAS S heet Tec Base S equally spaced, EnergyGuard RH, SECUROCK Membrane / 33 steel Cellular Concrete Stratavent Nailable staggered rows in the EnergyGuard RN Gypsum -Fiber Venting Base Sheet 7 in Fastener E (1..) center of the sheet Roof Board WB181 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 107 of 156 NNEMO I etc. TABLE 4c: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-2: LWC TO DECK, MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Lightweight Anchor Sheet Insulation Roof Cover (Note 15) System Deck MDP Concrete Fasteners Attach No. (Note 1) Type Attach Base Top Base Ply Cap Ply (psf) (Note 14) (Note 11) (Notes 6,7,8) CELCORE (FL2037): GAFG LAS #75 Base Sheet, 9-inch o.c. at the 2- Minimum 300 psi, Tri-Ply #75 Base Sheet, Drill-Tec Base inch side lap and 9- Min. 1.5-inch Min. 0.25-inch EverGuard Structural minimum 2-inch GAFGLAS #80 Ultima Base Sheet Fastener inch o.c. at two, EnergyGuard RA, SECUROCK Freedom LWC-52. concrete thick Celcore Sheet or GAFGLAS (1.7 in.) or Drill- equally spaced, EnergyGuard RH, Gypsum -Fiber OB500 None TPO / Self- 45.0 Cellular Concrete Stratavent Nailable Tec Base Sheet staggered rows in the EnergyGuard RN Roof Board adhered Fastener E (1.7 in.) Venting Base Sheet center of the sheet Min. 0.25-inch DensDeck GAFGLAS #75 Base Sheet, 9-inch o.c. at the 2- Prime or EverGuard Minimum 300 psi, Tri-Ply #75 Base Sheet, Drill-Tec Base inch side lap and 9- Min. 1.5-inch SECUROCK TPO / Sheet Fastener Gypsum -Fiber LWC-53. Structural minimum 2-inch GAFGLAS #80 Ultima Base (1.7 in.) or Drill- inch o.c. at two, EnergyGuard RA, Roof Board or OB500 None #1121, TPO -45.0 concrete thick Celcore Sheet or GAFGLAS equally spaced, EnergyGuard RH, 6-Square, Cellular Concrete Stratavent Nailable Tec Base Sheet staggered rows in the EnergyGuard RN min. 0.5-inch TPO 3- Fastener E (1.7 in.) StruVenting Base Sheet center of the sheet High Density n High Density Square Fiberboard Roof Insulation GAFG LAS #75 Base Sheet, Drill-Tec Base 9-inch o.c. at the 2- Min. 0.25-inch Minimum 300 psi, Tri-Ply #75 Base Sheet, inch side lap and 9- Min. 1.5-inch DensDeck LWC-54. Structural minimum 2-inch GAFGLAS #80 Ultima Base Sheet Fastener in.) or Drill- inch o.c. at two, EnergyGuard RA, Prime or OB500 None EverGuard / -45.0 concrete thick Celcore Sheet or GAFGLAS equally spaced, EnergyGuard RH, SECUROCK Cellular Concrete Stratavent Nailable Tec Tec Base Sheet staggered rows in the EnergyGuard RN Gypsum -Fiber WBTPO 181 Fastener E (1.7 in.) Venting Base Sheet center of the sheet Roof Board GAFGLAS #75 Base Sheet, 9-inch o.c. at the 2- Min. 0.25-inch Minimum 300 psi, Tri-Ply #75 Base Sheet, Drill-Tec Base inch side lap and 9- Min. 1.5-inch DensDeck EverGuard LWC-55. Structural minimum 2-inch GAFGLAS #80 Ultima Base Sheet Fastener in.) or Drill- inch o.c. at two, EnergyGuard RA, Prime or 0B500 None TPO Fleece - Back -45.0 concrete thick Celcore Sheet or GAFGLAS Tec Tec Base Sheet equally spaced, EnergyGuard RH, SECUROCK Membrane / Cellular Concrete Stratavent Nailable staggered rows in the EnergyGuard RN Gypsum -Fiber Venting Base Sheet Fastener E (1.7 in.) center of the sheet Roof Board WB181 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 108 of 156 NNEMO I etc. TABLE 41D: LIGHTWEIGHT CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) O DECK, MECHANICALLY ATTACHED: BONDED ROOF COVER Sheet Roof Cover (Note 15) 7Base MOP System Deck (Note 1) Lightweight Concrete (Note 14) Fasteners No. Type Attach Base Cap (psf) (Note 11) MEARLCRETE (FL13492): EverGuard Freedom TPO: Min. 22 ga., type B, Grade 7.5-inch o.c. in the 4-inch lap 33 vented steel Drill-Tec Locking and 12-inch o.c. in three, LWC-56. at max. 6 ft Min. 300 psi, min. 2-inch thick GAF StormSafe Anchor Impact Nail, min. 1.8- equally spaced, staggered None EverGuard -52.5 spans or min. Mearlcrete Sheet inch rows in the center of the Freedom TPO 2,500 psi sheet structural concrete PRE-EXISTENT CELLULAR LWC: EverGuard Freedom TPO: Min. 22 ga., type B, Grade 12-inch o.c. at the 4-inch lap 33 vented steel Min. 250-300 psi, min. 2-inch thick Drill-Tec #12 screws and 12-inch o.c. in three, LWC-57. at max. 6 ft pre-existent cellular lightweight GAF StormSafe Anchor and Drill-Tec equally spaced, staggered None EverGuard -45.0 spans or min. concrete Sheet AccuTrac Flat Plates rows in the center of the Freedom TPO 2,500 psi (engage steel deck) sheet structural concrete Hybrid Systems: Min. 22 ga., Min. 340 psi, min. 2-inch thick pre- GAFG LAS #75 Base Drill-Tec Base Sheet (Optional) One or two plies type B, Grade existent cellular lightweight Sheet, Tri-Ply #75 Base Fastener in.) Ruberoid 20 Smooth, Ruberoid EverGuard 40 vented steel concrete. Note: To qualify the LWIC Sheet, GAFGLAS #80 Drs as ec Base Sheet et 7-inch o.c. at min. 4-inch laps Mop Smooth, Ruberoid Mop Fleece- TPOBack LWC-58. atmax. 6 ft under this assembly, the selected Ultima Base Sheet, a Fastener E (1.7 in.), and 7-inch o.c. in two, Smooth 1.5 or Ruberoid Mop Plus Back -52.5 spans or min. fastener shall achieve an average GAFGLAS Stratavent Drill-Tec Locking equally spaced, staggered Smooth in hot asphalt or one or Membrane in 2,500 psi withdrawal of 60 lbf or greater Nailable Venting Base Impact Nail or center rows two plies Ruberoid HW 25 Smooth hot apshalt structural when tested per TAS105 or Sheet, Ruberoid 20 Trufast FM-290 or Ruberoid HW Smooth, torch- concrete ANSI/SPRI FX-1 Smooth applied EverGuard Min. 22 ga., Min. 340 psi, min. 2-inch thick pre- GAFGLAS #75 Base Drill-Tec Base Sheet One or two plies Ruberoid 20 TPO Fleece - type B, Grade existent cellular lightweight Sheet, Tri-Ply #75 Base Fastener in.) Smooth, Ruberoid Mop Smooth, Back 40 vented steel concrete. Note: To qualify the LWIC Sheet, GAFGLAS #80 et Drste ec Base Sheet as 7-inch o.c. at min. 4-inch laps Ruberoid Mop Smooth 1.5 or Membrane in LWC-59. at max. 6 ft under this assembly, the selected Ultima Base Sheet, Fastener E (1.7 in.), and 7-inch o.c. in two, Ruberoid Mop Plus Smooth in hot GAF 2-Part -52.5 sans or min. p fastener shall achieve an average f g GAFGLAS Stratavent Drill-Tec Locking equally spaced, staggered q y p gg asphalt or one or two lies(spatter), p p 2,500 psi withdrawal of 6016f or greater Nailable Venting Base Impact Nail or center rows Ruberoid HW 25 Smooth or LRF-XF LR structural when tested per TAS105 or Sheet, Ruberoid 20 Ruberoid HW Smooth, torch- (spatter) or concrete ANSI/SPRI FX-1 Smooth Trufast FM-290 applied OB500 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 109 of 156 NNEMO I etc. TABLE 41): LIGHTWEIGHT CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) O DECK, MECHANICALLY ATTACHED: BONDED ROOF Base Sheet COVER Roof Cover (Note 15) Systoem Deck (Note 1) Lightweight Concrete (Note 14) MDP Fasteners Type Attach Base Cap (ps ) (Note 11) Drill-Tec XHD EverGuard Min. 22 ga., Fastener with Drill- Fasteners located 3.75-inch TPO Fleece - type B, Grade Tec 2-3/8 in. Barbed from edge of sheet, and Back 50 steel at Min. 180 psi, min. 3-inch thick pre- Ruberoid Mop Smooth, XHD Plate or Drill- spaced 12-inch o.c. within (Optional) Ruberoid HW 25 Membrane in LWC-60. max. 6 ft spans existent cellular lightweight Ruberoid Mop Smooth Tec Eyehook the min. 6.25-inch wide laps. Smooth or Ruberoid HW Smooth, GAF 2-Part -60.0 or min. 2,500 concrete. 1.5 or Ruberoid Mop AccuSeam Plate, Laps sealed with min. 4-inch torch -applied (spatter), psi structural Plus Smooth fastened through wide heat -weld, LRF-XF concrete LWC to engage steel encapsulating the fastener (spatter) or deck row OB500 (spatter) Re -Roof Only: Min. 210 psi, min. 2- Min.22ga., inch thick pre-existent cellular Drill-Tec Base Sheet EverGuard type BV, Grade lightweight insulating concrete; Fastener (1.7 in.) or 7-inch o.c. at min. 4-inch laps TPO Fleece- 40 steel at Note: To qualify the pre-existent Drill-Tec Base Sheet and 7-inch o.c. in two,Fastener Ruberoid HW 25 Smooth or Back LWC-61. max. 6 ft spans LWIC under this assembly, the Ruberoid 20 Smooth Fast E (1.7 in.), equally spaced, staggered Ruberoid HW Smooth, torch Membrane in -82.5 or min. 2,500 selected fastener shall achieve an Tec Locking Drill -Impact center rows applied GAF 2-Part psi structural average withdrawal of 95lbf or Nail (spatter) or concrete greater when tested per AN51/5PRI hot asphalt FX-1 or TAS105. Re -Roof Only: Min. 210 psi, min. 2- Min.22ga., inch thick pre-existent cellular EverGuard type BV, Grade lightweight insulating concrete; GAFGLAS ft80 Ultima Drill-Tec Base Sheet 7-inch o.c. at min. 4-inch laps TPO Fleece- 40 steel at Note: To qualify the pre-existent Base Sheet or GAFGLAS Fastener (1.7 in.), and 7-inch o.c. in two, Ruberoid HW 25 Smooth or Back LWC-62. max. 6 ft spans LWIC under this assembly, the Stratavent Nailable Drill-Tec Locking equally spaced, staggered Ruberoid HW Smooth, torch Membrane in -82.5 or min. 2,500 selected fastener shall achieve an Venting Base Sheet Impact Nail center rows applied GAF 2-Part psi structural average withdrawal cf 95lbf or (spatter) or concrete greater when tested per AN51/5PRI hot asphalt FX-1 or TAS105. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 110 of 156 NNEMO I etc. TABLE 4E: LIGHTWEIGHT CONCRETE OVER STEEL DECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: LVIC . DECK, BONDED ROOF Lightweight Concrete (Note 14) Roof Cover (Note 15) MDP Deck (Note 1) Min. Compressive Min. 71: Type Type Attach (psf) Strength (psi) Thickness (in) CONCRECEL (FL5584 AND FL10500): Min. 22 ga., type BV, Grade 33 EverGuard TPO GAF 2-Part (spatter) or LAIC-63. steel at max. 6 ft spans Concrecel 290 2 Fleece -Back OB500 (spatter) -52.5 Membrane EusTIZELL (FL4994): EverGuard TPO Min. 22 ga., type BV, Grade 33 GAF 2-Part (spatter) or LWC-64. steel at max. 6 ft spans Elastizell 290 2 Fleece -Back OB500 (spatter) -52.5 Membrane EverGuard TPO Min. 22 ga., type BV, Grade 33 GAF 2-Part (spatter) or LWC-65. steel at max. 6 ft spans Elastizell 160 3 Fleece -Back Membrane OB500 (spatter) -60.0 MEARLCREfE (FL13492): EverGuard TPO LWC-66. Min. 22 ga., type BV, Grade 33 Mearlcrete 300 2 Fleece -Back EverGuard WB181 -52.5 steel at max. 6 ft spans Bonding Adheisve Membrane EverGuard TPO LWC-67. Min. 22 ga., type BV, Grade 33 Mearlcrete 300 2 Fleece -Back LRF-M or LRF-O, 4-inch -52.5 steel at max. 6 ft spans O.C. Membrane EverGuard TPO Min. 22 ga., type BV, Grade 33 GAF 2-Part (spatter) or LWC-68. steel at max. 6 ft spans Mearlcrete 300 2 Fleece -Back Membrane OB500 (spatter) -52.5 Min. 22 ga., type BV, Grade 33 EverGuard TPO GAF 2-Part (spatter) or LWC-69. steel at max. 6 ft spans Mearlcrete 290 2 Fleece -Back OB500 (spatter) -52.5 Membrane PRE-EXISTENT CELLULAR LWC: Pre-existent cellular lightweight insulating concrete; Note: To qualify LWC-70. Min. 22 ga., type BV, Grade 33 the LWIC under this assembly, a Drill-TecTM Base Sheet Fastener (1.7in.) or 400 2 EverGuard TPO #1121, TPO QSA or TPO -52.5 Steel; 6 ft spans Drill-Tec' Base Sheet Fastener E (1.7 in.) shall achieve MCRF of 1171bf or QSA LV50 greater when tested per TAS105. Pre-existent cellular lightweight insulating concrete; Note: To qualify EverGuard TPO LWC-71. Min. 22 ga., type BV, Grade 33 the LWIC under this assembly, a Drill-TecTM Base Sheet Fastener (1.7in.) or 180 2 Fleece -Back EverGuard W 8181 -52.5 steel at max. 6 ft spans Drill-Tec' Base Sheet Fastener E(1.7in.) shall achieve an average withdrawal Bonding Adhesive of 971bf or greater when tested perANSI/SPRI FX-1 or TAS305. Membrane Pre-existent cellular lightweight insulating concrete; Note: To qualify EverGuard TPO LWC-72. Min. 22 ga., type BV, Grade 33 the LWIC under this assembly, o Drill-Tec' Base Sheet Fastener (1.7in.) or 180 2 Fleece -Back GAF 2-Part (Spatter) or -52.5 steel at max. 6 ft spans Drill-Tec- Base Sheet Fastener E(1.7in.) shallachieve an average withdrawal OB500 (spatter) of 971bf or greater when tested perANSI/SPRI FX-1 or TAS305. Membrane NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 111 of 156 NNEMO I etc. TABLE 4F: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) BONDEDSYSTEM TYPE F: LWC TO DECK, ROOF COVER Lightweight Concrete (Note 14) Roof Cover (Note 15) Deck Syst em No. (Note 1) Type Min. Compressive Min. Type MDP Attach (psf) Strength (psi) Thickness (in) CELCORE(FL2037): Structural EverGuard TPO Fleece- LRF-M or LRF-0, LWC-74. concrete Celcore Cellular Concrete 200 2 Back Membrane ribbons 4-inch o.c. -300.0 Structural EverGuard TPO Fleece- GAF 2-Part LWC-75. Celcore Cellular Concrete 200 2 (spatter) or OB500 -300.0 concrete Back Membrane (spatter) CONCRECEL (FL5584 AND FL10500): Structural EverGuard TPO Fleece- EverGuard WB181 LWC-76. concrete Concrecel 200 2 Back Membrane Bonding Adhesive -225.0 Structural EverGuard TPO Fleece- GAF 2-Part LWC-77. Concrecel 200 2 (spatter) or OB500 -225.0 concrete Back Membrane (spatter) Structural EverGuard TPO Fleece- LRF-M or LRF-O, LWC-78. concrete Concrecel 200 2 Back Membrane ribbons 4-inch o.c. -225.0 ELASTIZELL (FL4994): Structural EverGuard TPO Fleece- EverGuard WB181 LWC-79. concrete Elastizell 220 2 Back Membrane Bonding Adhesive -200.0 Structural EverGuard TPO Fleece- GAF 2-Part LWC-80. Elastizell 220 2 (spatter) or OB500 -200.0 concrete Back Membrane (spatter) Structural EverGuard TPO Fleece- LRF-M or LRF-O, LWC-81. concrete Elastizell 200 2 Back Membrane ribbons 4-inch o.c. -210.0 SIPLAST INSULCEL (NOA 16-1024.02): Structural EverGuard TPO Fleece- LRF-M or LRF-O, 4- LWC-82. concrete Insulcel 200 2 Back Membrane inch o.c. 270 0 Structural EverGuard TPO Fleece- GAF 2-Part LWC-83. Insulcel 200 2 (spatter) or OB500 -270.0 concrete Back Membrane (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization N32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 112 of 156 NNEMO I etc. GHT CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: LWC . DECK, BONDED ROOF Lightweight Concrete (Note 14) Roof Cover (Note 15) System Deck No. (Note 1) Type Min. Compressive Min. Type MDP Attach (psf) Strength (psi) Thickness (in) MEARLCRETE (FL13492): Structural EverGuard TPO Fleece- LRF-M or LRF-O, LWC-84. concrete Mearlcrete 730 2 Back Membrane ribbons 6-inch o.c. -45.0 Structural EverGuard TPO Fleece- EverGuard WB181 LWC-85. concrete Mearlcrete 290 2 Back Membrane Bonding Adhesive -205.0 Structural EverGuard TPO Fleece- GAF 2-Part LWC-86. Mearlcrete 290 2 (spatter) or OB500 -205.0 concrete Back Membrane (spatter) Structural EverGuard TPO Fleece- LRF-M or LRF-O, LWC-87. concrete Mearlcrete 200 2 Back Membrane ribbons 4-inch o.c. -270.0 PRE-EXISTENT CELLULAR LWC: Structural Pre-existent cellular lightweight insulating concrete; Note: To qualify the LWICunderthis EverGuard TPOFleece- ribbons 4- LWC-88. concrete assembly, aDrill-TecTM Base Sheet Fastener (1.7in.)orDrill-TecTM Base Sheet Fastener E/1.7in.lshall 180 2 ran Back Membrane inch o. inch o.c. -92.5 achieve an average withdrawal of 971bf or greater when tested perANSI/SPRI FX-1 or TA5105. Structural Pre-existent cellular lightweight insulating concrete; Note: To qualify the LWIC under this EverGuard TPO Fleece- EverGuard WB181 LWC-89. concrete assembly, a Drill-TecTM Base Sheet Fastener(1.7in.) or Drill-TecTM Base Sheet Fastener E (1.7in.) shall 180 2 Back Membrane Bonding Adhesive -102.5 achieve an average withdrawal of 9716f or greater when tested perAN51/SPRI FX-1 or TAS105. Structural Pre-existent cellular lightweight insulating concrete; Note: To qualify the LWICunderthis EverGuard TPO Fleece- GAF 2-Part LWC-90. concrete assembly,aDrill-TecTM Base Sheet Fastener (1.7 in.l or Drill-TecTM Base Sheet FastenerE (1.7 in.l shall 180 2 Back Membrane (spatter) or OB500 -102.5 achieve an average withdrawal of971bforgreater when tested perAN51/SPRIFX-1orTAS305. (spatter) ) Structural Pre-existent cellular lightweight insulating concrete; Note: To qualify the LWICunderthis EverGuard Fleece- 4- LWC-91. concrete assembly, a Drill-TecTM Base Sheet Fastener (1.7in.) or Drill-TecTM Base Sheet FastenerE(1.7in.)shall 180 2 ran Back Membrane inch o.t. inchLRF-o.c. -112.5 achieve an average withdrawal of 971bf or greater when tested perANSI/SPRI FX-1 or TAS105. Structural Pre-existent cellular lightweight insulating concrete; Note: To qualify the LWICunderthis LWC-92. assembly, a Drill-TecTM Base Sheet Fastener (1.7in.) or Drill-TecTM Base Sheet FastenerE (1.71n.) shall 400 2 EverGuard TPO #1121 -127.5 concrete achieve MCRF of 11716f or greater when tested per TAS105. Structural Pre-existent cellular lightweight insulating concrete; Note: To qualify the LWIC under this EverGuard Fleece- LWC-93. concrete assembly, aDrill-TecTM Base Sheet Fastener (1.7in.) or Drill-TecTM ease Sheet Fastener (1.7in.) shall 400 2 e Back Membrane LRF-XF (spatter) -130.0 achieve MCRF of 1171bf or greater when tested per TAS105. Structural Pre-existent cellular lightweight insulating concrete; Note: To qualify the LWICunderthis LWC-94. assembly, a Drill-TecTM Base Sheet Fastener (1.7in.) or Drill-TecTM Base Sheet FastenerE (1.7in.) shall 400 2 EverGuard TPO TPO QSA -150.0 concrete achieve MCRF of 11716f or greater when tested per TAS105. Structural Pre-existent cellular lightweight insulating concrete; Note: To qualify the LWICunderthis LWC-95. assembly, a Drill-TecTM Base Sheet Fastener (1.7in.) or Drill-TecTM Base Sheet Fastener E (1.71n.) shall 400 2 EverGuard TPO TPO QSA LV50 -154.0 concrete achieve MCRF of 11716f or greater when tested per TAS105. Structural Pre-existent cellular lightweight insulating concrete; Note: To qualify the LWICunderthis EverGuard TPO LWC-96. concrete assembly, a Drill-TecTM Base Sheet Fastener(1.7in.) or Drill-TecTM Base Sheet FastenerE(1.7in.Jshall 540 2 EverGuard TPO #1121 BA 487.5 achieve an average withdrawal of 17816f orgreater when tested perANSI/SPRI FX-1 or TAS105. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 113 of 156 NNEMO I etc. TABLE 4G: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR .. R- SYSTEM TYPE F: TEMP ROOF / VAPOR BARRIER TO DECK, LWC TO TEMP ROOF / VAPOR BARRIER, BONDED ROOF COVER Lightweight Concrete (Note 14) Roof Cover (Note 15) System Deck Temp Roof/ Min, Min. MDP primer No. (Note 1) Vapor Barrier Type Compressive Thickness Type Attach (psf) Strength (psi) (in) PRE-EXISTENT CELLULAR LWC: Matrix 307 Ruberoid HW Pre-existent cellular lightweight insulating concrete; Note: To qualify EverGuard TPO EverGuard LWC-97. structural Premium Smooth, torch- the LWIC under this assembly, a Drill-TecTM Base Sheet Fastener (1.7 in.) or 180 2 Fleece -Back W8181 Bonding -102.5 concrete Asphalt Primer applied Drill-TecTM Base Sheet Fastener E (1.7in.) shall achieve an average withdrawal Membrane Adhesive of 9716f or greater when tested per AN51/SPRI FX-1 or TASIOS. Matrix 307 Ruberoid HIMPre-existent cellular lightweight insulating concrete; Note: To qualify EverGuard TPO LWC-98. Structura Premium Smooth, torch- the LWIC under this assembly , a Drill-TecTM Base Sheet Fastener (1.7 in.) or 180 2 Fleece -Back LRF-M, ribbons -92.5 Concrete Asphalt Primer applied Drill71bfor materwhense Sheet ener E stedpe.Tin.Jshall FX-1 rTAS10an ragewithdrawal of 9716f or greater when tested per AN51/SPRI FX-1 or TAS105. Membrane 4-incho.c. Matrix 307 Ruberoid HIMStructura Pre-existent cellular lightweight insulating concrete; Note: To qualify EverGuard TPO LWC-99. Premium Smooth, torch- the LWICunderthis assembly, a Drill-Tec' Base Sheet Fastener(1.7 in.) or 180 2 Fleece -Back LRF-0, ribbons -112.5 Concrete Asphalt Primer applied Sheet when perAn.JshaR achieve an average withdrawal Drill71bfor greater of 9716f or greater when tested per AN51/SPRI FX-1 or TAS105. Membrane 4-inch O.C. Matrix 307 Ruberoid HW Pre-existent cellular lightweight insulating concrete; Note: To qualify EverGuard TPO GAF 2-Part LWC-500. Structural Premium Smooth, torch- the LWIC under this assembly, a Drill-Tecm Base Sheet Fastener (1.7 in.) or 180 2 Fleece -Back (spatter) or -102.5 concrete Asphalt Primer applied Drill-TecTM Base sheet Fastener E(1.7in.) shall achieve an average withdrawal Membrane OB500(spatter) of 971bf or greater when tested perAN51/5PR1 FX-1 or TA5105. Matrix 307 Ruberoid HW Pre-existent cellular lightweight insulating concrete; Note: To qualify EverGuard TPO LWC-101. structuralthe Premium Smooth, torch- LWIC under this assembly, a Drill-Tec'" Base Sheet Fastener (1.7 in.) or 540 2 Fleece -Back OB500(spatter) -357.5 concrete Asphalt Primer applied Drill-TecTM ease Sheet Fastener (1.7 in.) shall achieve an overage withdrawal Membrane of 14616for greater when tested per AN51/SPRI FX-I or TA5105. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 114 of 156 NNEMO I etc. ..tREROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Deck Base Insulation Layer Top Insulation Layer MDP 7,.1..,d (Notes 1 & 12) Type Attach Type Attach Roof Cover (Note 15) (psfl(Notes 6,7,8) (Notes 6,7,8)reedom TPO: Existing (reroof) Min. 2-inch Min. 1-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers base EverGuard Freedom TPO /self CWF-1. Tedum Plank orTectum LS EnergyGuard RA, EnergyGuard RH or EnergyGuard OB500 insulation, flat or tapered 06500 adhered -45.0 Plank RN Existing (reroof) Min. 2-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, (OptionalAdditional layers base EverGuard Freedom TPO /self CWF-2. Tedum Plank orTectum LS EnergyGuard RA, EnergyGuard RH or EnergyGuard GAF 2-Part insulation, GAF 2-Part adhered -52.5 Plank orFibroplank RNflatortapered EverGuard TPO: Existing (reroof) Min. 2-inch Min. 1-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers base EverGuard TPO / #1121, TPO 3- CWF-3. Tectum Plank orTectum LS EnergyGuard RA, EnergyGuard RH or EnergyGuard OB500 OB500 -45.0 Plank RN insulation, flat or tapered Square, WB181 Existing (reroof) Min. 2-inch Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers base EverGuard TPO / #1121, TPO 3- CWF-4. Tedum Plank orTectum LS EnergyGuard RA, EnergyGuard RH or EnergyGuard GAF 2-Part insulation, flat or tapered GAF 2-Part Square, WB181 -52.5 Plank or Fibroplank RN New or existing (reroof) OB500, 6-inch o.c. (Optional) Additional layers base OB500, 6- CWF-5. Min. 2-inch EnergyGuard Polyiso Insulation to back -side of EverGuard TPO / #1121 -120.0 Min. 2-inch Tectum I Plank insulation insulation, flat or tapered inch o.c. New or existing (reroof) Min. 2-inch EnergyGuard Polyiso Insulation, OB500, 6-inch o.c. Min. 0.25-inch DensDeck Prime or OB500, 6- CWF-6. EnergyGuard RH, EnergyGuard RM, EnergyGuard to back -side of SECUROCK Gypsum -Fiber Roof EverGuard TPO / #1121 -127.5 Min. 2-inch Tectum I Plank RN or EnergyGuard Ultra insulation Board inch o.c. EverGuard TPO Fleece -Back Membrane: Existing (reroof) Min. 2-inch Min. 1-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers base EverGuard TPO Fleece -Back CWF-7. Tedum Plank or Tectum LS EnergyGuard RA, EnergyGuard RH or EnergyGuard OB500 insulation, flat or tapered OB500 Membrane / LRF-0, 12-inch o.c. -45.0 Plank RN Existing (reroof) Min. 2-inch (Optional) Min. 1-inch EnergyGuard Polyiso Min. 0.25-inch SECUROCK EverGuard TPO Fleece -Back CWF-8. Tedum Plank or Tectum LS Insulation, EnergyGuard RA, EnergyGuard RH or OB500 Gypsum -Fiber Roof Board OB500 Membrane / LRF-O, 12-inch o.c. -45.0 Plank EnergyGuard RN Existing (reroof) Min. 2-inch Min. 1-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers base EverGuard TPO Fleece -Back CWF-9. Tedum Plank orTectum LS EnergyGuard RH LRF-M insulation, flat or tapered LRF-M Membrane / LRF-M, 12-inch o.c. -45.0 Plank Existing (reroof) Min. 2-inch (Optional) Min. 1-inch EnergyGuard Polyiso Min. 0.25-inch SECUROCK EverGuard TPO Fleece -Back CWF-10. Tedum Plank orTectum LS Insulation, EnergyGuard RH LRF-M Gypsum -Fiber Roof Board LRF-M Membrane / LRF-M, 12-inch o.c. -45.0 Plank New or existing (reroof) Min. 2-inch EnergyGuard Polyiso Insulation, OB500, 6-inch o.c. (Optional) Additional layers base OB500, 6- EverGuard TPO Fleece -Back CWF-11. EnergyGuard RH, EnergyGuard RM, EnergyGuard to back -side of Membrane / LRF-M or LRF-O, 4- -120.0 Min. 2-inch Tectum I Plank RN insulation insulation, flat or tapered inch o.c. inch o.c. or GAF 2-Part (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMD ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 115 of 156 NNEMO I etc. ..DREROOF (TEAR -OFF) r(Notes SYSTEM TYPE A-1: BONDED Base Insulation Layer INSULATION, BONDED ROOF COVER Top Insulation Layer Deck Attach Attach MDP Roof Cover (Note 15) 1 & 12) Type Type (psfl (Notes 6,7,8) (Notes 6,7,8) Min. 2-inch EnergyGuard Polyiso Insulation, OBS00, 6-inch o.c. Min. 0.25-inch DensDeck Prime or EverGuard TPO Fleece -Back New or existing (reroof) CWF-12. EnergyGuard RH, EnergyGuard RM, EnergyGuard to back -side of SECUROCK Gypsum -Fiber Roof OB500, 6- Membrane/ UFF-M or LRF-O, 4- -127.5 Min. 2-inch Tectum I Plank RN or EnergyGuard Ultra insulation Board inch o.c. inch o.c. or GAF 2-Part (spatter) TABLE SB: CEIVIENTITIOUS WOOD FIBER DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER System Deck SYSTEM TYPE Base Insulation C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Top Insulation Layer I MDP Roof Cover (Note 35) Type Fasteners (Note 11) Attach No. (Note 1) Layer (Note 13) (psf) (Optional) One or Drill-Tec Polymer Gyptec with Drill-Tec 3" CWF-13. Existing (reroof) Min. 2-inch Tectum more layers, any Min. 1.5-inch EnergyGuard Gyptec Plates or Drill-Tec LD Fasteners with 1 per EverGuard Freedom TPO / self -q5.0* Plank or Tectum LS Plank combination RN or EnergyGuard Ultra Drill-Tec LD Plates; Minimum 2-inch 2.0 ft2 adhered fastener embedment. Existing (reroof) Min. 2.5-inch (Optional) One or Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with Drill-Tec 3" 1 per EverGuard TPO / #1121, TPO 6- CWF-14. Tectum Plank or Tectum LS Plank more layers, any RA, EnergyGuard RH Gyptec Plates (min. 2-inch embedment) 2.0 ft2 Square, TPO 3-Square, WB181 _q5.0* combination New or existing (reroof/recover) Min. (Optional) One or Min. 2-inch EnergyGuard Drill-Tec Locking Impact Nail (min. 1.8-inch 1 per EverGuard TPO / #1121, TPO 6- CWF-15. 3-inch Tectum I Plank more layers, any Polyiso Insulation or embedment) 1.3 ft2 Square, TPO 3-Square -52.5 combination EnergyGuard RH (Optional) One or Min. 2-inch EnergyGuard EverGuard TPO Fleece -Back CWF-16. New or existing (reroof/recover) Min. more layers, any Polyiso Insulation or Drill-Tec Locking Impact Nail (min. 1.8-inch 1 per Membrane / LRF-M or LRF-O, 4-inch -52.5 3-inch Tectum I Plank combination EnergyGuard RH embedment) 1.3 ft2 o.c. or GAF 2-Part (spatter), LRF-XF (spatter) or OB500 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 116 of 156 NNEMOjetc. TABLE 6A: GYPSUM DECKS - REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer MDP No. (Notes 1 & 22) Type Attach Type Attach Roof Cover (Note 15) (psf) 7 (Notes 6,7,8) (Notes 6,7,8) EverGuard Freedom TPO: Existing poured gypsum (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard Min. 0.25-inch SECUROCK Gypsum- EverGuard Freedom TPO / self G-1. or gypsum plank RH or EnergyGuard RN OB500 Fiber Roof Board OB500 adhered _135.0 Existing poured gypsum Min. 1-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer of base EverGuard Freedom TPO / self G 2 or gypsum plank EnergyGuard Ultra OB500 insulation OB500 adhered _142.5 G-3. Existing poured gypsum Min. 1-inch EnergyGuard RA OB500 (Optional) Additional layer of base OB500 EverGuard Freedom TPO / self -187.5 or gypsum plank insulation adhered Existing poured gypsum Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer of base EverGuard Freedom TPO / self G 4 or gypsum plank EnergyGuard Ultra GAF 2-Part insulation GAF 2-Part adhered -142.5 Existing poured gypsum Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch SECUROCK Gypsum- EverGuard Freedom TPO / self G-5. or gypsum plank EnergyGuard RN GAF 2-Part Fiber Roof Board GAF 2-Part adhered _257.5 EverGuard TPO / EverGuard TPO #1121 Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: lu- Existing poured gypsum Min. 0.25-inch DensDeck or DensDeck EverGuard TPO / #1121, TPO 3- G-6. or gypsum plank Min. 2-inch, min. 2.0 pcf, Insulfoam EPS 08500 Prime OB500 Square -120.0 Existing poured gypsum Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch DensDeck or DensDeck EverGuard TPO / #1121, TPO 3- G 7. or gypsum plank EnergyGuard RN OB500 Prime OB500 Square -130.0 Existing poured gypsum (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard Min. 0.25-inch SECUROCK Gypsum- EverGuard TPO / #1121, TPO 3- G 8 or gypsum plank RH or EnergyGuard RN OB500 Fiber Roof Board OB500 Square _135.0 Existing poured gypsum Min. 1-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer of base EverGuard TPO / #1121, TPO 3- G-9. or gypsum plank EnergyGuard Ultra OB500 insulation OB500 Square -270.0 Existing poured gypsum (Optional) Additional layer of base EverGuard TPO / #1121, TPO 3- G-10. or gypsum plank Min. 1-inch EnergyGuard RA OB500 insulation OB500 Square -387.5 G-11. Existing poured gypsum Min. 1.5-inch thick, min. 1.25 pcf Insulfoam EPS GAF 2-Part Min. 0.25-inch DensDeck Prime or GAF 2-Part EverGuard TPO / #1121, TPO 3- 87 5 or gypsum plank SECUROCK Gypsum -Fiber Roof Board Square Existing poured gypsum Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch DensDeck or DensDeck EverGuard TPO / #1121, TPO 3- G-12. or gypsum plank EnergyGuard RN or Min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part Prime GAF 2-Part Square -130.0 Insulfoam EPS Existing poured gypsum One or more layers, min. 1.5-inch thick, min. 1.5 pcf Min. 0.25-inch SECUROCK Gypsum- EverGuard TPO / #1121, TPO 3- G-13. or gypsum plank Insulfoam EPS GAF 2-Part Fiber Roof Board GAF 2-Part Square -180.0 Existing poured gypsum One or more layers, min. 1.5-inch thick, min. 2.0 pcf Min. 0.25-inch SECUROCK Gypsum- EverGuard TPO / #1121, TPO 3- G-14. or gypsum plank Insulfoam EPS GAF 2-Part Fiber Roof Board GAF 2-Part Square -240.0 Existing poured gypsum Min. 2-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch SECUROCK Gypsum- EverGuard TPO / #1121, TPO 3- G-15. or gypsum plank EnergyGuard RN GAF 2-Part Fiber Roof Board GAF 2-Part Square _247.5 Existing poured gypsum Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer of base EverGuard TPO / #1121, TPO 3- G-16. or gypsum plank EnergyGuard Ultra GAF 2-Part insulation GAF 2-Part Square -257.5 EverGuard TPO / EverGuard WB181 Bonding Adhesive: NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 117 of 156 NNEMO I etc. TABLE 6A: GYPSUM DECKS - REROOF (TEAR -OFF) Deck SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer MDP Type Attach Type Attach 7G-17. Ntes 1 & 12) 7E.istingo Roof Cover (Note 15) (Psf) (Notes 6,7,8) (Notes 6,7,8) poured gypsum Min. 2-inch, min. 2.0 pcf, Insulfoam EPS OB500 Min. 0.25-inch DensDeck Prime OB500 EverGuard TPO / WB181 -120.0 sum plank G-18. Existing poured gypsum Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or OB500 Min. 0.25-inch DensDeck Prime OB500 EverGuard TPO / WB181 -130.0 or gypsum plank EnergyGuard RN G-19. Existing poured gypsum Min. 1.5-inch EnergyGuard Polyiso Insulation, OB500 (Optional) Additional layer of base OB500 EverGuard TPO / WB181 -135.0 or gypsum plank EnergyGuard Ultra insulation G-20. Existing poured gypsum Min. 1-inch EnergyGuard RA OB500 (Optional) Additional layer of base OB500 EverGuard TPO / WB181 -210.0 or gypsum plank insulation G-21. Existing poured gypsum Min. 1.5-inch thick, min. 1.25 pcf Insulfoam EPS GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part EverGuard TPO / WB181 -87.5 or gypsum plank Existing poured gypsum Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or G 22. EnergyGuard RN or Min. 1.5-inch thick, min. 1.5 pcf GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part EverGuard TPO / WB181 -130.0 or gypsum plank Insulfoam EPS G-23. Existing poured gypsum Min. 1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional) Additional layer of base GAF 2-Part EverGuard TPO / WB181 -257.5 or gypsum plank EnergyGuard Ultra insulation EverGuard TPO / EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Existing poured gypsum Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, Min. 0.25-inch DensDeck Prime or EverGuard TPO / TPO 6-Square, G 24. or gypsum plank EnergyGuard RN or EnergyGuard Ultra, min. 2-inch, min. OB500 SECUROCK Gypsum -Fiber Roof Board OB500 TPO 3-Square -45.0 2.0 pcf, Insulfoam EPS Existing poured gypsum Min. 1.5-inch EnergyGuard RA, EnergyGuard RN or (Optional) Additional layer of base EverGuard TPO / TPO 6-Square, G-25. or gypsum plank EnergyGuard Ultra OB500 insulation OB500 TPO 3-Square -135.0 Existing poured gypsum Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or Min. 0.25-inch DensDeck Prime or EverGuard TPO / TPO 6-Square, G-26. or gypsum plank EnergyGuard RN or min. 1.5-inch thick, min. 1.25 pcf GAF 2-Part SECUROCK Gypsum -Fiber Roof Board GAF 2-Part TPO 3-Square -45.0 Insulfoam EPS Existing poured gypsum (Optional) Additional layer of base EverGuard TPO / TPO 6-Square, G 27. or gypsum plank Min. 1.5-inch EnergyGuard RA, EnergyGuard RN GAF 2-Part insulation GAF 2-Part TPO 3-Square -257.5 EverGuard TPO Fleece -Back Membrane: G 28 Existing poured gypsum Min. 1-inch EnergyGuard RH OB500 (Optional) Additional layer of base OB500 EverGuard TPO Fleece -Back -75.0 or gypsum plank insulation Membrane / LRF-O, 6-inch o.c. EverGuard TPO Fleece -Back Existing poured gypsum Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer of base Membrane / GAF 2-Part G 29 or gypsum plank EnergyGuard Ultra GAF 2-Part insulation GAF 2-Part (spatter), LRF-XF (spatter) or -257.5 OB500 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 118 of 156 NNEMO I etc. TABLE 6B: GYPSUM •REROOF (TEAR -OFF) SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHOR BONDED INSULATION, BONDED ROO Anchor Sheet Base Insulation Top Insulation System Deck Attach Roof Cover MDP No. (Note 1) Type Fasteners (Note 21) Attach Temp Roof Type Attach Type (Notes (Note 15) (psf) 6,7,8) Existing GAFGLAS Drill-Tec Base Sheet Ruberoid 25 Min. 0.25-inch DensDeck EverGuard poured #75 Base Fastener (1.2 in.) or 9-inch o.c. in the min. 2- Smooth, SBS H W Min. 1.5-inch Prime or SECUROCK TPO / #1121, G-30. gypsum Sheet orTri- Drill-Tec Base Sheet inch laps and 18-inch o.c. Smooth, Ruberoid EnergyGuard RA, OB500 Gypsum -Fiber Roof Board OB500 TPO 6-Square, -45.0* or Ply #75 Base Fastener E (1.2 in.) in two, equally spaced Torch Smooth or EnergyGuard RH, or min. 0.5-inch TPO 3-Square, gypsum Sheet (W/D > 105 Ibf) center rows Tri-Ply APP Smooth EnergyGuard RN Structodek HD Fiberboard WB181 plank Roof Insulation TABLE 6c: GYPSUM DECKS - REROOF (TEAR -OFF) SYSTEMTYPEB-1: MECHANICALLY ATTACHED BASE • BONDED TOP INSULATION,BONDED ROOCOVER Base Insulation Layer System Deck Top Insulation Layer MDP No. (Note 1) Type Fasten (Note 11) Attach Type Attach Roof Cover (Note 15) (psf) (Notes 6,7,8) EverGuard Freedom TPO: Existing poured Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with 1 per Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard Freedom G-31. gypsum or Polyiso Insulation, EnergyGuard Drill-Tec 3" Gyptec Plates 2.0 ft2 EnergyGuard Ultra LRF-M TPO / self adhered -45.0* gypsum plank Ultra (Min. 2-inch embedment) Existing poured Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard Freedom G-32. gypsum or Insulation, EnergyGuard Ultra Drill-Tec 3" Gyptec Plates 2.9 ft2 EnergyGuard Ultra LRF-M TPO / self adhered -45.0 gypsum plank (Min. 2-inch embedment) Existing poured Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with 1 per Optional min. 0.5-inch EnergyGuard Polyiso EverGuard Freedom G-33. gypsum or Polyiso Insulation, EnergyGuard Drill-Tec 3" Gyptec Plates 2.0 ft2 Insulation, EnergyGuard Ultra followed by min. LRF-M TPO / self adhered -45.0* gypsum plank Ultra (Min. 2-inch embedment) 0.25-inch SECUROCK Gypsum -Fiber Roof Board Existing poured Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Optional min. 0.5-inch EnergyGuard Polyiso EverGuard Freedom G-34. gypsum or Insulation, EnergyGuard Ultra Drill-Tec 3" Gyptec Plates 2.9 ft2 Insulation, EnergyGuard Ultra followed by min. LRF-M TPO / self adhered -45.0* gypsum plank (Min. 2-inch embedment) 0.25-inch SECUROCK Gypsum -Fiber Roof Board Existing poured Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per EverGuard Freedom G-35. gypsum or Insulation, EnergyGuard Ultra Drill-Tec 3" Gyptec Plates 3.2 ft : Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Board LRF-M TPO /self adhered -45.0* gypsum plank (Min. 2-inch embedment) Existing poured Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with 1 per Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard Freedom G-36. gypsum or Polyiso Insulation, EnergyGuard Drill-Tec 3" Gyptec Plates 2.0 ft2 EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH OB500 TPO /self adhered -45.0* gypsum plank Ultra or EnergyGuard RH (Min. 2-inch embedment) Existing poured Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard Freedom G-37. gypsum or Insulation, EnergyGuard Ultra or Drill-Tec 3" Gyptec Plates 2.9 ft2 EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH OB500 TPO / self adhered -45.0* gypsum plank EnergyGuard RH (Min. 2-inch embedment) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 119 of 156 NNEMO I etc. TABLE 6c: GYPSUM DECKS - .. (TEAR -OFF) SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE BONDED TOP INSULATION, BONDED ROOF System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) Type Fasten (Note 11) Attach Type Attach Roof Cover (Note 15) (psf) (Notes 6,7,8) Existing poured Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with Optional min. 0.5-inch EnergyGuard Polyiso G-38. gypsum or Polyiso Insulation, EnergyGuard Drill-Tec 3" Gyptec Plates 1 per Insulation, EnergyGuard Ultra or min. 1.5-inch OB500 EverGuard Freedom -45.0* gypsum plank Ultra or EnergyGuard RH (Min. 2-inch embedment) 2.0 ft2 EnergyGuard RH followed by min. 0.25-inch TPO / self adhered SECUROCK Gypsum -Fiber Roof Board Existing poured Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with Optional min. 0.5-inch EnergyGuard Polyiso G-39. gypsum or Insulation, EnergyGuard Ultra or Drill-Tec 3" Gyptec Plates per Insulation, EnergyGuard Ultra or min. ch OB500 EverGuard Freedom -45.0* gypsum plank EnergyGuard RH (Min. 2-inch embedment) . 29 ft2 -inch EnergyGuard RH followed min. 0.25inch TPO /self adhered SECUROCK Gypsum -Fiber Roof Board o Existing poured Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per EverGuard Freedom G-40. gypsum or Insulation, EnergyGuard Ultra Drill-Tec 3" Gyptec Plates 3.2 ft2TPO Min. 0.25-inch SECUROCK Gypsum -Fiber Roof Board OB500 -45.0* / self adhered gypsum plank (Min. 2-inch embedment) EverGuard TPO: Existing poured Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with 1 per Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard / 121, G-41. gypsum or Polyiso Insulation, EnergyGuard Drill-Tec 3" Gyptec Plates 2.0 ft2 EnergyGuard Ultra LRF-M re, O 3- TPO 6-Square, TPO 3- -45.0* gypsum plank Ultra (Min. 2-inch embedment) Square, WB181 Existing poured Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / #1121, G-42. gypsum or Insulation, EnergyGuard Ultra Drill-Tec 3" Gyptec Plates 2.9 ft2 EnergyGuard Ultra LRF-M TPO 6-Square, TPO 3- -45.0* gypsum plank (Min. 2-inch embedment) Square, WB181 Existing poured Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with Optional min. 0.5-inch EnergyGuard Polyiso EverGuard TPO / #1121, G-43. gypsum or Polyiso Insulation, EnergyGuard Drill-Tec 3" Gyptec Plates 1 per 2.0 ft2 Insulation, EnergyGuard Ultra followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum - LRF-M TPO 6-Square, TPO 3- -45.0* gypsum plank Ultra (Min. 2-inch embedment) Fiber Roof Board Square, W6181 Existing poured Drill-Tec Polymer Gyptec with Optional min. 5-inch EnergyGuard Polyiso 0. EverGuard TPO / #1121, G-44. gypsum Min. 2-inch EnergyGuard Polyiso 3" Gyptec Plates 1 per Insulation, EnergyGuard Ultra followed by min. LRF-M e, TPO 3- 6e, -45.0* plank gypsum plank Insulation, EnergyGuard Ultra (Min. (Min. 2-inch embedment) 2.9 ft2 0.25-inch DensDeck Prime or SECUROCK Gypsum- WB Square, WB181 SquTPOare, Fiber Roof Board Existing poured Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / #1121, G-45. gypsum or Insulation, EnergyGuard Ultra Drill-Tec 3" Gyptec Plates 3.2 ft2 Gypsum -Fiber Roof Board LRF-M TPO 6-Square, TPO 3- -45.0* gypsum plank (Min. 2-inch embedment) Square, WB181 Existing poured Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / #1121, G-46. gypsum or Polyiso Insulation, EnergyGuard Drill-Tec 3" Gyptec Plates .per 20 ft2 EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH OB500 TPO 6-Square, TPO 3- -45.0* gypsum plank Ultra or EnergyGuard RH (Min. 2-inch embedment) Square, WB181 Existing poured Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO / #1121, G-47. gypsum or Insulation, EnergyGuard Ultra or Drill-Tec 3" Gyptec Plates 2.9 ftz EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH OB500 TPO 6-Square, TPO 3- -45.0* gypsum plank EnergyGuard RH (Min. 2-inch embedment) Square, WB181 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 120 of 156 NNEMO I etc. TABLE 6c: GYPSUM DECKS - .. (TEAR -OFF) SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE BONDED TOP INSULATION, BONDED ROOF System Deck Base Insulation Layer Top Insulation Layer M DP No. (Note 1) Type Fasten (Note 11) Attach Type Attach Roof Cover (Note 15) (psf) (Notes 6,7,8) Optional min. 0.5-inch EnergyGuard Polyiso Existing poured Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with Insulation, EnergyGuard Ultra or min. 1.5-inch EverGuard TPO / #1121, G-48. SYP sum or Polyiso Insulation, EnergyGuard Y SY Drill-Tec 3" Gyptec Plates YP 2.0 ft2 EnergyGuard RH followed b min. 0.25-inch gY Y OBS00 TPO 6-Square, TPO 3- 9 -45.0* gypsum plank Ultra or EnergyGuard RH (Min. 2-inch embedment) .per DensDeck Prime or SECUROCK Gypsum -Fiber Roof Square, WB181 Board Optional min. 0.5-inch EnergyGuard Polyiso Existing poured Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Insulation, EnergyGuard Ultra or min. 1.5-inch EverGuard TPO / #1121, G-49. gypsum or Insulation, EnergyGuard Ultra or Drill-Tec 3" Gyptec Plates 2.9 ft2 EnergyGuard RH followed by min. 0.25-inch OB500 TPO 6-Square, TPO 3- -45.0* gypsum plank EnergyGuard RH (Min. 2-inch embedment) DensDeck Prime or SECUROCK Gypsum -Fiber Roof Square, WB181 Board Existing poured Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Min. 0.25-inch DensDeck Prime or SECUROCK EverGuard TPO / #1121, G-50. gypsum or Insulation, EnergyGuard Ultra Drill-Tec 3" Gyptec Plates : 3.2 ft2 Gypsum -Fiber Roof Board OBS00 TPO 6-Square, TPO 3- -45.0* gypsum plank (Min. 2-inch embedment) Square, WB181 EverGuard TPO Fleece -Back Membrane: Existing poured Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with 1 per Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard ran Fleece- PO Back Membrane / G-51. gypsum or Polyiso Insulation, EnergyGuard Drill-Tec 3" Gyptec Plates 2.0 ft2 EnergyGuard Ultra LRF-M WB181 or LRF-M or -45.0* gypsum plank Ultra (Min. 2-inch embedment) LRF-O, 12-inch o.c. Existing poured Drill-Tec Polymer Gyptec with EverGuard Fleece - G-52. gypsum or Min. 2-inch EnergyGuard Polyiso Drill-Tec 3" Gyptec Plates ec 3" 1 per Min. 0.5-inch EnergyGuard Polyiso Insulation, LRF-M Back Membrane / ran -45.0* gypsum plank Insulation, EnergyGuard Ultra (Min. embedment) 2.9 ft2 EnergyGuard Ultra WB181 or LRF-M or LRF-O, 12-inch o.c. Existing poured Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with Optional min. 0.5-inch EnergyGuard Polyiso EverGuard TPO Fleece- G-53. gypsum or Polyiso Insulation, EnergyGuard Drill-Tec 3" Gyptec Plates 1 per I Insulation, EnergyGuard Ultra followed by min. LRF-M Back Membrane / M bransLRF-M -45.0* gypsum plank Ultra (Min. 2-inch embedment) ft2 0.25-inch DensDeck Prime or SECUROCK Gypsum- WB181 or or Fiber Roof Board LRF-O, 12-inch o.c. Existing poured Drill-Tec Polymer Gyptec with Optional min. 0.5-inch EnergyGuard Polyiso EverGuard TPO Fleece - G-54. gypsum or Min. 2-inch EnergyGuard Polyiso Drill-Tec 3" Gyptec Plates 1 per Insulation, EnergyGuard Ultra followed by min. LRF-M Back Membrane / -45.0* gypsum plank Insulation, EnergyGuard Ultra (Min. 2-inch embedment) 2 9 ft2 0.25-inch DensDeck Prime or SECUROCK Gypsum- WB181 or LRF-M or Fiber Roof Board LRF-O, 12-inch o.c. Existing poured Drill-Tec Polymer Gyptec with EverGuard TPO Fleece - Min. 2-inch EnergyGuard Polyiso Drill-Tec 3" Gyptec Plates 1 per Min. 0.25-inch DensDeck Prime or SECUROCK LRF-M Back Membrane / -45.0* gypsum plank Insulation, EnergyGuard Ultra (Min. 2-inch embedment) 3.2 ft2 Gypsum -Fiber Roof Board WB181 or LRF-M or LRF-O, 12-inch o.c. Existing poured Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with 1 per Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece- Back Membrane / G-56. gypsum Polyiso Insulation, EnergyGuard 3" Gyptec Plates 2.0 ft2 EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH OB500 WB181 or LRF-M or -45.0* plank gypsum plank Ultra or EnergyGuard RH (Min. (Min. 2-inch embedment) LRF-O, 12-inch o.c. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'^ Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 121 of 156 NNEMO I etc. TABLE 6c: GYPSUM DECKS - .. (TEAR -OFF) SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE BONDED TOP INSULATION, BONDED ROOF System Deck Base Insulation Layer Top Insulation Layer MDP No. (Note 1) Type Fasten (Note 11) Attach Type Attach Roof Cover (Note 15) (psf) (Notes 6,7,8) Existing poured Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with EverGuard TPO Fleece- 1 per Min. 0.5-inch EnergyGuard Polyiso Insulation, Back Membrane / G-57. gypsum or Insulation, EnergyGuard Ultra or 3" Gyptec Plates. 2.9 ft2 EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH OB500 WB181 or LRF-M or -45.0* plank gypsum plank EnergyGuard RH (Min. (Min2-inch embedment) LRF-O, 12-inch o.c. Optional min. 0.5-inch EnergyGuard Polyiso EverGuard TPO Fleece - Existing poured Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with er 1 per Insulation, EnergyGuard Ultra or min. 1.5-inch Back Membrane / Back M brans G-58. gypsum or Polyiso Insulation, EnergyGuard Drill-Tec 3" Gyptec Plates 2.0 EnergyGuard RH followed by min. 0.25-inch OB500 or WB181oror LRF-Mo.o -45.0* gypsum plank Ultra or EnergyGuard RH (Min. 2-inch embedment)DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board Optional min. 0.5-inch EnergyGuard Polyiso EverGuard TPO Fleece - Existing poured Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with 1 per Insulation, EnergyGuard Ultra or min. 1.5-inch Back Membrane / G-59. gypsum or Insulation, EnergyGuard Ultra or Drill-Tec 3" Gyptec Plates 2.9 ft2 EnergyGuard RH followed by min. 0.25-inch OB500 WB181 or LRF-M or -45.0* gypsum plank EnergyGuard RH (Min. 2-inch embedment) DensDeck Prime or SECUROCK Gypsum -Fiber Roof LRF-O, 12-inch o.c. Board Existing poured Drill-Tec Polymer Gyptec with EverGuard TPO Fleece - Min. 2-inch EnergyGuard Polyiso 1 per Min. 0.25-inch DensDeck Prime or SECUROCK Back Membrane / G-60. gypsum Insulation, EnergyGuard Ultra iTec 3" Gyptec Plates 3.2 ft2 Gypsum -Fiber Roof Board OB500 WB181 or LRF-M or -45.0* plank gypsum plank (Mn (Min. 2-inch embedment) LRF-O, 12-inch o.c. TABLE 6D: GYPSUM rREROOF (TEAR -OFF) System Deck Base Insulation Layer SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Top Insulation Layer Roof Cover (Note 15) MDP Type Fasteners (Note 21) Attach No. (Note 1) (Note 13) (Psf) Existing poured (Optional) One or Min1 . .5-inch EnergyGuard RN or Drill-Tec Polymer Gyptec with Drill-Tec 3" Gyptec Plates 1 per EverGuardEverGuard Freedom TPO /self G-61. gypsum or gypsum more layers, any EnergyGuard Ultra or Drill-Tec LD Fasteners with Drill-Tec LD Plates 2.0 ft adhered -45.0* plank combination (Minimum 2-inch fastener embedment) Existing poured (Optional) One or Min. 1.5-inch EnergyGuard Polymer Gyptec with Drill-Tec 3" Gyptec Plates 1 per EverGuard Freedom TPO /self G-62. gypsum or gyp sum more layers, an y Polyiso Insulation, EnergyGuard y gy iTec (Min. 2-inch embedment) 2.0 ft' adhered -45.0* plank combination Ultra, EnergyGuard RH Existing poured (Optional) One or Drill-Tec Polymer Gyptec with Drill-Tec 3" Gyptec Plates G-63. gypsum or gypsum more layers, any Min. 2-inch EnergyGuard Polyiso (Min. 2-inch embedment); 8 parts per min. 4 x 8 ft 1 per EverGuard Freedom TPO / self 45.0* plank combination Insulation, EnergyGuard Ultra board with parts installed 24-inch o.c. in two parallel 4.0 ft2 adhered rows, 12 inches from the 8 ft edges of the board Existing poured (Optional) One or Polymer Gyptec with Drill-Tec 3" Gyptec Plates 1 per EverGuard Freedom TPO /self G-64. gypsum or gypsum more layers, any Min. 2-inch EnergyGuard RH (Min. 2-inch embedment) (Min. 2 2.9 ft adhered -45.0* plank combination NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 122 of 156 NNEMO I etc. TABLE 6D: GYPSUM DECKS - REROOF (TEAR -OFF) System Deck Base Insulation Layer ATTACHEDSYSTEM TYPE C-1: MECHANICALLY INSULATION, BONDED ROOF Top Insulation Layer Roof Cover (Note 15) MDP Type Fasteners (Note 11) Attach No. (Note 1) (Note 13) (Psf) Existing poured (Optional) One or Min. 1.5-inch EnergyGuard Drill-Tec Polymer Gyptec with Drill-Tec 3" Gyptec Plates 1 per EverGuard TPO / #1121, TPO 6- G-65. gypsum or gypsum more layers, any Polyiso Insulation, EnergyGuard (Min. 2-inch embedment) 2.0 ft2 Square, TPO 3-Square, WB181 -45.0* plank combination Ultra, EnergyGuard RH Existing poured (Optional) One or Drill-Tec Polymer Gyptec with Drill-Tec 3" Gyptec Plates G-66. gypsum or gypsum more layers, any Min. 2-inch EnergyGuard Polyiso (Min. 2-inch embedment); 8 parts per min. 4 x 8 ft 1 per EverGuard TPO / #1121, TPO 6- -45.0* plank combination Insulation, EnergyGuard Ultra board with parts installed 24-inch o.c. in two parallel 4.0 ft2 Square, TPO 3-Square, WB181 rows, 12 inches from the 8 ft edges of the board Existing poured (Optional) One or Polymer Gyptec with Drill-Tec 3" Gyptec Plates 1 per EverGuard 6- / #1123-Square, G-67. gypsum or gypsum more layers, any Min. 2-inch EnergyGuard RH (Min. 2-inch embedment) (Min. 2.9 ft2 3- B18PO Square, TPO 3-Square, W8181 -45.0* plank combination Existing poured (Optional) One or Min. 1.5-inch EnergyGuard Dri. Polymer Gyptec with Drill-Tec 3" Gyptec Plates 1 per EverGuard TPO Fleece -Back G-68. gypsum or gypsum more layers, any Polyiso Insulation, EnergyGuard 2-i (Min. 2-inch embedment) 2.0 ft2 Membrane / W8181 or LRF-M or -45.0* plank combination Ultra, EnergyGuard RH LRF-0, 12-inch o.c. Existing poured (Optional) One or Min. 2-inch EnergyGuard Polyiso Drill-Tec Polymer Gyptec with Drill-Tec 3" Gyptec Plates 1 per EverGuard TPO Fleece -Back G-69. gypsum or gypsum more layers, any Insulation, EnergyGuard Ultra, (Min. 2-inch embedment) 2.9 ft2 Membrane / WB181 or LRF-M or -45.0* plank combination EnergyGuard RH LRF-0, 12-inch o.c. Existing poured (Optional) One or Min. 2-inch EnergyGuard Polyiso Drill-Tec Locking Impact Nail (minimum withdrawal 1 per EverGuard TPO / #1121, TPO 6- G-70. gypsum or gypsum more layers, any Insulation or EnergyGuard RH resistance at slated embedment> 1401bf) 1.3 ft2 Square, TPO 3-Square -52.5 plank I combination Existing poured (Optional) One or EverGuard TPO Fleece -Back G-71. or more layers, any Min. 2-inch EnergyGuard Polyiso Drill-Tec Locking Impact Nail (minimum withdrawal 1 per Membrane / LRF-M or LRF-O, 4- -52.5 gypsum gypsum plank combination Insulation or EnergyGuard RH resistance at slated embedment> 1401bf) 1.3 ft2 inch o.c. or GAF 2-Part (spatter), LRF-XF (spatter) or OB500 (spatter) TABLE 6F: GYPSUM • •• • System No. Deck (Notes 1 & 12) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER Primer / Treatment Roof Cover (Note 15) MDP (psf) G-73. Existing poured gypsum or gypsum plank None EverGuard TPO Fleece -Back Membrane / WB181 -90.0 G-74. Existing poured gypsum or gypsum plank None EverGuard TPO Fleece -Back Membrane / GAF 2-Part (spatter) -95.0 G-75. Existing poured gypsum or gypsum plank None EverGuard TPO Fleece -Back Membrane / OB500 (spatter) -280.0 G-76. Existing poured gypsum or gypsum plank SureBond Primer at 0.5 gal/square EverGuard TPO Fleece -Back Membrane / GAF 2-Part (spatter) -327.5 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 123 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer7-7177 Top Insulation Layer System Substrate (Notes 1 & 12) Attach Attach Roof Cover (Note 15) (Ps � No. Type Type (Notes 6,7,8) (Notes 6,7,8) EverGuard Freedom TPO: R-1. Existing smooth -or granule -surfaced BUR or smooth- or Min. 1-inch EnergyGuard Polyiso Insulation, GAF 2-Part None N/A EverGuard Freedom TPO / granule -surfaced modified bitumen EnergyGuard Ultra self adhered _45.0 Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard Freedom TPO / R 2 BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part of base insulation GAF 2-Part self adhered _110.0 gravel, overstructural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard Freedom TPO / R-3. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation 6-inch o.c. of base insulation 6-inch o.c. self adhered _157.5 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or R-4. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard Freedom TPO / _200.0 BUR, brushed/spudded and vacuumed to remove loose 4-inch o.c. of base insulation 4-inch o.c. self adhered gravel, over structural concrete deck Existing smooth -surface modified bitumen over struct. (Optional) Min. 1.5-inch EnergyGuard RA, Min. 0.25-inch SECUROCK EverGuard Freedom TPO / R-5. concrete deck EnergyGuard RH or EnergyGuard RN GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part self adhered 222 5 Existing smooth -surface BUR or granule -surface modified Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard Freedom TPO / R-6. bitumen over struct. concrete deck Board GAF 2-Part None N/A self adhered _245.0 Min. 1.5-inch EnergyGuard RA, EnergyGuard RH Min. 0.25-inch SECUROCK EverGuard Freedom TPO / R-7. Existing smooth -surfaced BUR over struct. concrete deck or EnergyGuard RN GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part self adhered -262.5 Existing granule -surfaced modified bitumen over struct. Min. 1.5-inch EnergyGuard RA, EnergyGuard RH Min. 0.25-inch SECUROCK EverGuard Freedom TPO / R-8. concrete deck or EnergyGuard RN GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part self adhered -270.0 R9 Existing smooth -or granule -surfaced BUR or smooth -or Min. 1-inch EnergyGuard Polyiso Insulation, LRF-M None N/A EverGuard Freedom TPO/ granule -surfaced modified bitumen EnergyGuard Ultra self adhered -45.0 Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard Freedom TPO / R-10. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M of base insulation LRF-M self adhered _110.0 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-M, 6- (Optional) Additional layer LRF-M, 6- EverGuard Freedom TPO / R-11. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnerGuard Poliso Insulation gyy inch o.c. of base insulation inch o.c. self adhered _157.5 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-M, 4- (Optional) Additional layer LRF-M, 4- EverGuard Freedom TPO / R-12. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. self adhered _200.0 gravel, over structural concrete deck NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 MEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 124 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Min. 0.5-inch EnergyGuard Existing smooth- orgranule-surfaced BUR or smooth- or (Optional) Min. 0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, EverGuard Freedom TPO / R-13. granule -surfaced modified bitumen over structural LRF-M EnergyGuard HD Polyiso LRF-M -75.0 concrete deck Insulation or min. 1.5-inch EnergyGuard RH Insulation, EnergyGuard HD self adhered Plus Polyiso Insulation Existing smooth- orgranule-surfaced BUR or smooth- or Min. 0.5-inch EnergyGuard Polyiso Insulation, (Optional) Min. 0.25-inch EverGuard Freedom TPO / R-14. granule -surfaced modified bitumen over structural LRF-M SECUROCK Gypsum -Fiber LRF-M 75.0 concrete deck EnergyGuard Ultra gy Roof Board self adhered Existing smooth- orgranule-surfaced BUR or smooth- or Min. 0.5-inch EnergyGuard Polyiso Insulation, (Optional) Min. 0.25-inch EverGuard Freedom TPO / R-15. granule -surfaced SBS or granule -surfaced APP modified LRF-M SECUROCK Gypsum -Fiber LRF-M -225.0 bitumen overstructural concrete deck EnerGuard Ultr gya Roof Board self adhered Existing smooth- orgranule-surfaced BUR or smooth -or Min. 1-inch EnergyGuard Polyiso Insulation, EverGuard Freedom TPO/ r R-16. granule -surfaced modified bitumen EnergyGuard Ultra LRF-XF None N/A self adhered -45.0 Existing smooth- or granule -surfaced BUR; smooth -or granule surfaced SB5 modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard Freedom TPO / R-17. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF of base insulation LRF-XF self adhered -110.0 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-XF, 6- (Optional) Additional layer LRF-XF, 6- EverGuard Freedom TPO / R-18. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. self adhered _157.5 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-XF, 4- (Optional) Additional layer LRF-XF, 4- EverGuard Freedom TPO / R-19. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. self adhered _200.0 gravel, over structural concrete deck Existing smooth -surface modified bitumen over struct. (Optional) Min. 1.5-inch EnergyGuard RA or Min. 0.25-inch SECUROCK EverGuard Freedom TPO / R-20. concrete deck EnergyGuard RH LRF-XF Gypsum -Fiber Roof Board LRF-XF self adhered 222 5 Existing smooth -surface BUR or granule -surface modified Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard Freedom TPO / R-21. bitumen overstruct. concrete deck Board LRF-XF None LRF-XF self adhered _245.0 Min. 1.5-inch EnergyGuard RA or EnergyGuard Min. 0.25-inch SECUROCK EverGuard Freedom TPO / R-22. Existing smooth -surfaced BUR over struct. concrete deck RH LRF-XF Gypsum -Fiber Roof Board LRF-XF self adhered -262.5 Existing granule -surfaced modified bitumen over struct. Min. 1.5-inch EnergyGuard RA or EnergyGuard Min. 0.25-inch SECUROCK EverGuard Freedom TPO / R-23. concrete deck RH LRF-XF Gypsum -Fiber Roof Board LRF-XF self adhered -270.0 Existing smooth- orgranule-surfaced BUR; smooth -or Min. 1-inch EnergyGuard Polyiso Insulation, EverGuard Freedom TPO / R-24. granule -surfaced SBS modified bitumen or granule- EnergyGuard Ultra OB500 None N/A self adhered -45.0 surfaced APP modified bitumen Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard Freedom TPO / R-25. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation OB500 of base insulation OB500 self adhered _110.0 gravel, over structural concrete deck NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMo ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 125 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth -or granule -surfaced BUR; smooth -or Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer EverGuard Freedom TPO / R-26. granule -surfaced SB5 modified bitumen or granule- EnergyGuard Ultra OB500 of base insulation OB500 self adhered -120.0 surfaced APP modified bitumen over struct. concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced OB500, 6- (Optional) Additional layer OB500, 6- EverGuard Freedom TPO / R 27 BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnerGuard Poliso Insulation gyy inch o.c. of base insulation inch o.c. self adhered _157.5 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced OB500, 4- (Optional) Additional layer OB500, 4- EverGuard Freedom TPO / R 2B BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnerGuard Poliso Insulation gyy inch o.c. of base insulation inch o.c. self adhered _200.0 gravel, over structural concrete deck Min. 0.5-inch EnergyGuard Existing smooth -or granule -surfaced BUR; smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, EverGuard Freedom TPO / R-29. granule -surfaced SBS modified bitumen or granule- OB500 EnergyGuard HD Polyiso OB5o0 -97.5 surfaced APP modified bitumen over struct. concrete deck Insulation or min. 1.5-inch EnergyGuard RH Insulation, EnergyGuard HD self adhered Plus Polyiso Insulation Existing smooth -or granule -surfaced BUR; smooth -or (Optional) Min. 1.5-inch EnergyGuard RA, Min. 0.25-inch SECUROCK EverGuard Freedom TPO / R-30. granule -surfaced SBS modified bitumen or granule- EnergyGuard RH, EnergyGuard RN OB500 Gypsum -Fiber Roof Board OB500 self adhered -120.0 surfaced APP modified bitumen over struct. concrete deck Existing smooth- or granule -surfaced BUR; smooth- or (Optional) Min. 0.25-Inch granule -surfaced SBS modified bitumen or granule- Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard Freedom TPO / R-31. surfaced APP modified bitumen overstructural concrete EnergyGuard Ultra OB500 SECUROCK Gypsum -Fiber OB500 self adhered -225.0 deck Roof Board EverGuard TPO in EverGuard TPO #1121 Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Min. 1.5-inch EnergyGuard RA, EnergyGuard RH (Optional) Min. 0.25-inch EverGuard TPO / #1121, R-32. Existing asphalt BUR or mineral surface cap sheet Hot Asphalt DensDeck Prime or min. Hot asphalt -45.0 or EnergyGuard RN 7/16-inch OSB TPO 3-Square R-33. Existing smooth-orgranule-surfaced BUR orsmooth-or Min. 1-inch EnergyGuard Polyiso Insulation, GAF 2-Part None N/A EverGuard TPO #1121, granule -surfaced modified bitumen EnergyGuard Ultra TPO 3-Square -45.0 Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / #1121, R-34. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part of base insulation GAF 2-Part TPO 3-Square -110.0 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or R-35. granule surfaced SB5 modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard TPO / #1121, -157.5 BUR, brushed/spudded and vacuumed to remove loose 6-inch o.c. of base insulation 6-inch o.c. TPO 3-Square gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard TPO / #1121, R-36. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation 4-inch o.c. of base insulation 4-inch o.c. TPO 3-Square -200.0 gravel, overstructural concrete deck NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 126 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth- orgranule-surfaced BUR; smooth -or Min. 0.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers EverGuard TPO / #1121, R-37. granule -surfaced SB5 or APP modified bitumen over EnergyGuard Ultra, EnergyGuard RH, GAF 2-Part GAF 2-Part -180.0 structural concrete deck EnergyGuard RN base insulation TPO 3-Square Existing smooth -surfaced modified bitumen overstruct. Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer EverGuard TPO / #1121, R-38. concrete deck EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part TPO 3-Square 222.5 Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer EverGuard TPO / #1121, R-39. Existing smooth -surface BUR over struct. concrete deck EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part TPO 3-Square -262.5 Existing granule -surface modified bitumen overstruct. Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer EverGuard TPO / #1121, R-40. concrete deck EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part TPO 3-Square -270.0 Existing smooth-orgranule-surfaced BUR orsmooth- or Min. 1.5-inch EnergyGuard RA, EnergyGuard RH Min. 0.25-inch DensDeck or EverGuard TPO / #1121, R-41. granule -surfaced SBS orgranule-surfaced APP modified or EnergyGuard RN or Min. 1.5-inch thick, min. GAF 2-Part GAF 2-Part -130.0 bitumen overstructural concrete deck 1.5 pcf Insulfoam EPS DensDeck Prime TPO 3-Square Existing smooth-orgranule-surfaced BUR or smooth -or Min. 0.25-inch DensDeck EverGuard TPO/#1121, R-42. granule -surfaced SBS or granule -surfaced APP modified Min. 1.5-inch thick, min. 1.25 pcf Insulfoam EPS GAF 2-Part Prime or SECUROCK GAF 2-Part 87.5 bitumen overstructural concrete deck Gypsum -Fiber Roof Board TPO 3-Square Existing smooth-orgranule-surfaced BUR orsmooth- or One or more layers, min. 1.5-inch thick, min. Min. 0.25-inch SECUROCK EverGuard TPO / #1121, R-43. granule -surfaced SB5 or granule -surfaced APP modified 1.5 pcf Insulfoam EPS GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part TPO 3-Square -180.0 bitumen overstructural concrete deck Existing smooth -surfaced modified bitumen over struct. (Optional) Min. 2-inch EnergyGuard RA, Min. 0.25-inch SECUROCK EverGuard TPO / #1121, R 44 concrete deck EnergyGuard RH or EnergyGuard RN or min. GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part TPO 3-Square 222 5 1.5-inch thick, min. 2.0 pcf Insulfoam EPS Existing smooth -surface BUR or granule -surface modified One or more layers, min. 1.5-inch thick, min. Min. 0.25-inch SECUROCK EverGuard TPO / #1121, R-45. bitumen over struct. concrete deck 2.0 pcf Insulfoam EPS GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part TPO 3-Square -240.0 Existing smooth -surface BUR or granule -surface modified Min. 0.25-inch SECUROCK Gypsum -Fiber Roof EverGuard TPO / #1121, R-46. bitumen over struct. concrete deck Board GAF 2-Part None N/A TPO 3-Square _245.0 Existing smooth -surface BUR orgranule surface modified Min. 2-inch EnergyGuard RA, EnergyGuard RH Min. 0.25-inch SECUROCK EverGuard TPO / #1121, R-47. bitumen over struct. concrete deck or EnergyGuard RN GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part TPO 3-Square -247.5 R 48 Existing smooth-orgranule-surfaced BUR orsmooth- or Min. 1-inch EnergyGuard Polyiso Insulation, LRF-M None N/A EverGuard TPO / #1121, -45.0 granule -surfaced modified bitumen EnergyGuard Ultra TPO 3-Square Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / #1121, R-49. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M of base insulation LRF-M TPO 3-Square _110.0 gravel, overstructural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-M, 6- (Optional) Additional layer LRF-M, 6- EverGuard TPO / #1121, R-50. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. TPO 3-Square _157.5 gravel, overstructural concrete deck NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 MEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 127 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced LRF-M, 4- (Optional) Additional layer LRF-M, 4- EverGuard TPO / #1121, R-51. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. TPO 3-Square -200.0 gravel, overstructural concrete deck Min. 0.5-inch EnergyGuard Existing smooth- or granule -surfaced BUR or smooth- or (Optional) Min. EnergyGuard Polyiso RH H D Polyiso Insulation, EverGuard TPO / #1121, R-52. granule -surfaced modified bitumen over structural LRF-M EnergyGuard HD Polyiso LRF-M -75.0 concrete deck Insulation or min. 1.5-inch EnergyGuard RH min. Insulation, EnergyGuard HD TPO 3-Square Plus Polyiso Insulation Existing smooth- or granule -surfaced BUR or smooth- or Min. 0.5-inch EnergyGuard Polyiso Insulation, Min. 0.5-inch Structodek EverGuard TPO / #1121, R-53. granule -surfaced modified bitumen over structural EnergyGuard Ultra LRF-M High Density Fiberboard LRF-M TPO 3-Square 82 5 concrete deck Roof Insulation (Optional) Min.0.25-inch Existing smooth-orgranule-surfaced BUR orsmooth- or Min. 0.5-inch EnergyGuard Polyiso Insulation, DensDeck Prime or EverGuard TPO / #1121, R-54. granule -surfaced modified bitumen over structural EnergyGuard Ultra LRF-M SECUROCK Gypsum -Fiber LRF-M TPO 3-Square -75.0 concrete deck Roof Board (Optional when using base Existing smooth -or granule -surfaced BUR or smooth -or (Optional when using coverboard)Min. 0.5-inch insulation) Min. 0.25-inch EverGuard TPO/#1121, R-55. granule -surfaced SBS or granule -surfaced APP modified EnergyGuard Polyiso Insulation, EnergyGuard LRF-M DensDeck Prime or LRF-M -225.0 bitumen overstructural concrete deck Ultra or min. 1.5-inch EnergyGuard RH SECUROCK Gypsum -Fiber TPO 3-Square Roof Board R-56. Existing smooth -or granule -surfaced BUR or smooth -or Min. 1-inch EnergyGuard Polyiso Insulation, LRF-XF None N/A EverGuard TPO #1121, 450 granule -surfaced modified bitumen EnergyGuard Ultra TPO 3-Square Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / #1121, R-57. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF of base insulation LRF-XF TPO 3-Square _110.0 gravel, overstructural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-XF, 6- (Optional) Additional layer LRF-XF, 6- EverGuard TPO / #1121, R-58. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. TPO 3-Square -157.5 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-XF, 4- (Optional) Additional layer LRF-XF, 4- EverGuard TPO / #1121, R-59. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. TPO 3-Square _200.0 gravel, overstructural concrete deck Existing smooth-orgranule-surfaced BUR; smooth -or Min. 0.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers EverGuard TPO / #1121, R-60. granule -surfaced SBS or APP modified bitumen over EnergyGuard Ultra or EnergyGuard RH LRF-XF base insulation LRF-XF TPO 3-Square -180.0 structural concrete deck Existing smooth -surfaced modified bitumen overstruct. Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer EverGuard TPO / #1121, R-61. concrete deck EnergyGuard Ultra LRF-XF of base insulation LRF-XF TPO 3-Square 222.5 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 128 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer EverGuard TPO / #1121, R-62. Existing smooth -surface BUR over struct. concrete deck EnergyGuard Ultra LRF-XF of base insulation LRF-XF TPO 3-Square -262.5 Existing granule -surface modified bitumen overstruct. Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer EverGuard TPO / #1121, R-63. concrete deck EnergyGuard Ultra LRF-XF of base insulation LRF-XF TPO 3-Square -270 . 0 Existing smooth-orgranule-surfaced BUR orsmooth- or Min. 1.5-inch EnergyGuard RA or EnergyGuard Min. 0.25-inch DensDeck or EverGuard TPO / #1121, R-64. granule -surfaced SBS or granule -surfaced APP modified RH LRF-XF DensDeck Prime LRF-XF TPO 3-Square -130.0 bitumen over structural concrete deck Existing smooth -surfaced modified bitumen over struct. (Optional) Min. 2-inch EnergyGuard RA or Min. 0.25-inch SECUROCK EverGuard TPO / #1121, R-65. concrete deck EnergyGuard RH LRF-XF Gypsum -Fiber Roof Board LRF-XF TPO 3-Square 222.5 R-66. Existing smooth -surface BUR or granule -surface modified Min. 0.25-inch SECUROCK Gypsum -Fiber Roof LRF-XF None N/A EverGuard TPO / #1121, bitumen over struct. concrete deck Board TPO 3-Square _245.0 Existing smooth -surface BUR or granule surface modified Min. 2-inch EnergyGuard RA or EnergyGuard Min. 0.25-inch SECUROCK EverGuard TPO / #1121, R-67. bitumen over struct. concrete deck RH LRF-XF Gypsum -Fiber Roof Board LRF-XF TPO 3-Square 247.5 Existing smooth-orgranule-surfaced BUR; smooth -or Min.1-inch EnergyGuard Polyiso Insulation, EverGuard TPO/#1121, R-68. granule -surfaced SB5 modified bitumen or granule- surfaced APP modified bitumen EnergyGuard Ultra OB500 None N/A TPO 3-Square -45.0 Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / #1121, R-69. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation OB500 of base insulation OB500 TPO 3-Square _110.0 gravel, over structural concrete deck Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Additional layer EverGuard TPO/#1121, R-70. granule -surfaced SBS modified bitumen or granule- Min. 1.5-inch EnergyGuard Ultra OB500 OB500 -120.0 surfaced APP modified bitumen over struct. concrete deck of base insulation TPO 3-Square Existing smooth- or granule -surfaced BUR; smooth- or R-71. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation OB500, 6- (Optional) Additional layer OB500, 6- EverGuard TPO / #1121, -157.5 BUR, brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. TPO 3-Square gravel, overstructural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced 0B500, 4- (Optional) Additional layer OB500, 4- EverGuard TPO / #1121, R 72 BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. TPO 3-Square _200.0 gravel, over structural concrete deck Min. 0.5-inch EnergyGuard Existing smooth- or granule -surfaced BUR; smooth- or (Optional) Min. 0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, EverGuard TPO / #1121, R-73. granule -surfaced SB5 modified bitumen or granule- OB500 EnergyGuard HD Polyiso OB500 97 5 surfaced APP modified bitumen overstruct. concrete deck Insulation or min. 1.5-inch EnergyGuard RH Insulation, EnergyGuard HD TPO 3-Square Plus Polyiso Insulation Existing smooth-orgranule-surfaced BUR; smooth -or Min. 0.5-inch EnergyGuard Polyiso Insulation, Min. 0.5-inch Structodek EverGuard TPO / #1121, R-74. granule -surfaced SBS modified bitumen or granule- OB500 High Density Fiberboard OB500 82.5 surfaced APP modified bitumen over struct. concrete deck d Ultra EnergyGuard ra Roof Insulation TPO 3-Square NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 129 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth- orgranule-surfaced BUR; smooth -or Min. 0.25-inch DensDeck EverGuard TPO/#1121, R-75. granule -surfaced SB5 modified bitumen or granule- surfaced APP modified bitumen Min. 1.5-inchlnsulfoam OB500 prime OB500 TPO 3-Square 45.0 Min. 0.25-inch DensDeck or Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Min. 1.5-inch EnergyGuard RA, DensDeck Prime or EverGuard TPO / #1121, R-76. granule -surfaced SBS modified bitumen or granule- EnergyGuard RH, EnergyGuard RN , min. 2-inch, OB500 OB500 -120.0 surfaced APP modified bitumen over struct. concrete deck min. 2.0 pcf, Insulfoam EPS SECUROCK Gypsum -Fiber TPO 3-Square Roof Board (Optional when using base Existing smooth-orgranule-surfaced BUR; smooth -or (Optional when using coverboard) Min. 0.5-inch insulation) Min. 0.25-inch EveEve EverGuard TPO / #1121, R-77. granule -surfaced SBS or APP modified bitumen over EnergyGuard Polyiso Insulation, EnergyGuard OB500 DensDeck Prime or OB500 -225.0 structural concrete deck Ultra or min. 1.5-inch EnergyGuard RH SECUROCK Gypsum -Fiber TPO 3-Square Roof Board EverGuard TPO / EverGuard WB382 Bonding Adhesive: R78 Existing smooth- orgranule-surfaced BUR or smooth -or Min. 1-inch EnergyGuard Polyiso Insulation, GAF 2-Part None N/A EverGuard TPO WB181 -45.0 granule -surfaced modified bitumen EnergyGuard Ultra Existing smooth- or granule -surfaced BUR; smooth -or R 79 granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional) Additional layer GAF 2-Part EverGuard TPO / W8181 -110.0 BUR, brushed/spudded and vacuumed to remove loose of base insulation gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or R-80. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard TPO / WB181 -157.5 BUR, brushed/spudded and vacuumed to remove loose 6-inch o.c. of base insulation 6-inch o.c. gravel, overstructural concrete deck Existing smooth-orgranule-surfaced BUR; smooth -or Min. 0.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers R-81. granule -surfaced SBS or APP modified bitumen over EnergyGuard Ultra, EnergyGuard RH, GAF 2-Part GAF 2-Part EverGuard TPO / WB181 -180.0 structural concrete deck EnergyGuard RN base insulation Existing smooth- or granule -surfaced BUR; smooth- or R-82. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard TPO / WB181 -200.0 BUR, brushed/spudded and vacuumed to remove loose 4-inch o.c. of base insulation 4-inch o.c. gravel, overstructural concrete deck R-83. Existing smooth -surfaced modified bitumen over structural Min. 1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional) Additional layer GAF 2-Part EverGuard TPO / WB181 -222.5 concrete deck EnergyGuard Ultra of base insulation R-84. Existing smooth -surface BUR over structural concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation, GAF 2-Part (Optional) Additional layer GAF 2-Part EverGuard TPO / WB181 -245.0 EnergyGuard Ultra of base insulation Existing granule -surface modified bitumen overstructural Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer R-85. concrete deck EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part EverGuard TPO / WB181 -270.0 Min.0.25-inch Min.0.25- Existing smooth- or granule -surfaced BUR or smooth- or inch DensDeck Prime or R-86. granule -surfaced SB5 orgranule-surfaced APP modified Min. 1.5-inch thick, min. 1.25 pcf Insulfoam EPS GAF 2-Part GAF 2-Part EverGuard TPO / WB181 -87.5 bitumen over structural concrete deck SECUROCK Gypsum -Fiber Roof Board NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 130 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Min.0.25- Existingsmooth- or granule -surfaced BUR aced BUR or smooth- or (Optional) Min. 1.5-inch EnergyGuard RA, inch DensDeck Prime oraced R-87. granule -surfaced SBS or granule -surfaced APP modified EnergyGuard RH or EnergyGuard RN or Min. GAF 2-Part GAF 2-Part EverGuard TPO / WB181 -130.0 bitumen over structural concrete deck 1.5-inch thick, min. 1.5 pcf Insulfoam EP$ ROCK Gypsum -Fiber Roof Board R 88 Existing smooth -or granule -surfaced BUR orsmooth-or Min. 1-inch EnergyGuard Polyiso Insulation, LRF-M None N/A EverGuard TPO / WB181 -45.0 granule -surfaced modified bitumen EnergyGuard Ultra Existing smooth- orgranule-surfaced BUR; smooth -or R 89 granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional) Additional layer LRF-M EverGuard TPO / WB181 -110.0 BUR, brushed/spudded and vacuumed to remove loose of base insulation gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or R-90. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M, 6- (Optional) Additional layer LRF-M, 6- EverGuard TPO / WB181 -157.5 BUR, brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or R-91. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M, 4- (Optional) Additional layer LRF-M, 4- EverGuard TPO / WB181 -200.0 BUR, brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. gravel, overstructural concrete deck Min. 0.5-inch EnergyGuard Existing smooth-orgranule-surtaced BUR orsmooth- or (Optional) 0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, R-92. granule -surfaced modified bitumen over structural Insulation or min. Min. 1.5-inch EnergyGuard LRF-M EnergyGuard HD Polyiso LRF-M EverGuard TPO / WB181 -75.0 concrete deck RH Insulation, EnergyGuard HD Plus Polyiso Insulation (Optional) Min. 0.25-inch Existing smooth -or granule -surfaced BUR or smooth- or Min. 0.5-inch EnergyGuard Polyiso Insulation, DensDeck Prime or R-93. granule -surfaced modified bitumen over structural concrete deck EnergyGuard Ultra LRF-M SECUROCK Gypsum -Fiber LRF-M EverGuard TPO / WB181 -75.0 Roof Board (Optional when using base Existing smooth -or granule -surfaced BUR or smooth -or (Optional when using coverboard)Min. 0.5-inch insulation) Min. 0.25-inch R-94. granule -surfaced SB5 or granule -surfaced APP modified EnergyGuard Polyiso Insulation, EnergyGuard LRF-M DensDeck Prime or LRF-M EverGuard TPO / W13181 -225.0 bitumen over structural concrete deck Ultra or min. 1.5-inch EnergyGuard RH SECUROCK Gypsum -Fiber Roof Board R-95. Existing smooth -or granule -surfaced BUR or smooth -or Min. 1-inch EnergyGuard Polyiso Insulation, LRF-XF None N/A EverGuard TPO WB181 -45.0 granule -surfaced modified bitumen EnergyGuard Ultra Existing smooth- or granule -surfaced BUR; smooth -or R-96. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional) Additional layer LRF-XF EverGuard TPO / WB181 -110.0 BUR, brushed/spudded and vacuumed to remove loose of base insulation gravel, over structural concrete deck NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02819 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 131 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth- or granule -surfaced BUR; smooth- or R-97. granule surfaced SB5 modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF, 6- (Optional) Additional layer LRF-XF, 6- EverGuard TPO / WB181 -157.5 BUR, brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. gravel, over structural concrete deck Existing smooth- orgranule-surfaced BUR; smooth -or Min. 0.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers R-98. granule -surfaced SB5 or APP modified bitumen over LRF-XF LRF-XF EverGuard TPO / WB181 -180.0 structural concrete deck EnergyGuard Ultra or EnergyGuard RH base insulation Existing smooth- or granule -surfaced BUR; smooth- or R-99. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF, 4- (Optional) Additional layer LRF-XF, 4- EverGuard TPO / WB181 -200.0 BUR, brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch O.C. gravel, over structural concrete deck R-100. Existing smooth -surfaced modified bitumen over structural Min. 1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional) Additional layer LRF-XF EverGuard TPO / WB181 -222.5 concrete deck EnergyGuard Ultra of base insulation R-101. Existing smooth -surface BUR over structural concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional) Additional layer LRF-XF EverGuard TPO / WB181 -245.0 EnergyGuard Ultra of base insulation R-102. Existing granule -surface modified bitumen overstructural Min. 1.5-inch EnergyGuard Polyiso Insulation, LRF-XF (Optional) Additional layer LRF-XF EverGuard TPO / WB181 -270.0 concrete deck EnergyGuard Ultra of base insulation Min. 0.25-inch Min.0.25- Existing smooth- orgranule-surfaced BUR or smooth- or (Optional) Min. 1.5-inch EnergyGuard RA or inch DensDeck Prime or R-103. granule -surfaced SB5 or granule -surfaced APP modified EnergyGuard RH LRF-XF SECUROCK Gypsum -Fiber LRF-XF EverGuard TPO / WB181 -130.0 bitumen over structural concrete deck Roof Board Existing smooth- orgranule-surfaced BUR; smooth -or Min.1-inch EnergyGuard Polyiso Insulation, R-104. granule -surfaced SB5 modified bitumen or granule- OB500 None N/A EverGuard TPO / WB181 -45.0 surfaced APP modified bitumen EnergyGuard Ultra Existing smooth- or granule -surfaced BUR; smooth -or R-105. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional) Additional layer OB500 EverGuard TPO / WB181 -110.0 BUR, brushed/spudded and vacuumed to remove loose of base insulation gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or (Optional) Additional layer R-106. granule -surfaced SBS modified bitumen or granule- Min. 1.5-inch EnergyGuard Ultra OB500 OB500 EverGuard TPO / WB181 -120.0 surfaced APP modified bitumen over struct. concrete deck of base insulation Existing smooth- or granule -surfaced BUR; smooth- or R-107. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation OB500, 6- (Optional) Additional layer OB500, 6- EverGuard TPO / W6181 -157.5 BUR, brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch O.C. gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or R-108. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation OB500, 4- (Optional) Additional layer OB500, 4- EverGuard TPO / WB181 -200.0 BUR, brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. gravel, over structural concrete deck NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 132 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Min. 0.5-inch EnergyGuard Existing smooth -or granule -surfaced BUR; smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, R-109. granule -surfaced SBS modified bitumen or granule- OB500 EnergyGuard HD Polyiso OB500 EverGuard TPO / WB181 -97.5 surfaced APP modified bitumen over struct. concrete deck Insulation or min. 1.5-inch EnergyGuard RH Insulation, EnergyGuard HD Plus Polyiso Insulation Existing smooth- or granule -surfaced BUR; smooth- or Min. 0.25-inch DensDeck R-110. granule -surfaced SBS modified bitumen or granule- Min. 1.5-inch Insulfoam 0B500 OB500 EverGuard TPO / WB181 -45.0 surfaced APP modified bitumen Prime Existing smooth -or granule -surfaced BUR; smooth -or Min. 1.5-inch EnergyGuard RA, EnergyGuard Min. 0.25-inch DensDeck R-111. granule -surfaced SBS modified bitumen or granule- RH, EnergyGuard RN, min. 2-inch, min. 2.0 pcf, OB500 OB500 EverGuard TPO / WB181 -120.0 surfaced APP modified bitumen over struct. concrete deck Insulfoam EPS prime (Optional when using base Existing smooth-orgranule-surfaced BUR; smooth -or (Optional when using coverboard) Min. 0.5-inch insluation) Min. 0.25-inch R-112. granule -surfaced SBS or APP modified bitumen over EnergyGuard Polyiso Insulation, EnergyGuard OB500 DensDeck Prime or OB500 EverGuard TPO / WB181 -225.0 structural concrete deck Ultra or min. 1.5-inch EnergyGuard RH SECUROCK Gypsum -Fiber Roof Board EverGuard TPO in EverGuard TPO 6 Square Low VOC Bonding Adhesive or EverGuard TPO 3 Square Low VOC Bonding Adhesive: Min. 1.5-inch EnergyGuard RA, EnergyGuard RH (Optional) Min. 0.25-inch EverGuard TPO / TPO 5- R-113. Existing asphalt BUR or mineral surface cap sheet Hot Asphalt Hot asphalt -45.0 or EnergyGuard RN DensDeck Prime Square, TPO 3-Square R-114. Existing smooth-orgranule-surfaced BUR or smooth -or Min. 1-inch EnergyGuard Polyiso Insulation, GAF 2-Part None N/A EverGuard TPO /TPO 5- granule -surfaced modified bitumen EnergyGuard Ultra Square, TPO 3-Square -45.0 Existing smooth- or granule -surfaced BUR; smooth -or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / TPO 6- R-115. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part of base insulation GAF 2-Part Square, TPO 3-Square _110.0 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard TPO / TPO 6- R-116. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation 6-inch o.c. of base insulation 6-inch o.c. Square, TPO 3-Square _157.5 gravel, over structural concrete deck Existing smooth -or granule -surfaced BUR; smooth -or Min. 0.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers EverGuard TPO / TPO 6- R-117. granule -surfaced SBS or APP modified bitumen over EnergyGuard Ultra, EnergyGuard RH, GAF 2-Part GAF 2-Part -180.0 structural concrete deck EnergyGuard RN base insulation Square, TPO 3-Square Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard TPO / TPO 6- R-118. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation 4-inch o.c. of base insulation 4-inch o.c. Square, TPO 3-Square _200.0 gravel, over structural concrete deck Existing smooth -surface modified bitumen over struct. Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer EverGuard TPO / TPO 6- R-119. concrete deck EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part Square, TPO 3-Square 222 5 Existing smooth -surface BUR or granule -surface modified Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer EverGuard TPO / TPO 6- R-120. bitumen over struct. concrete deck EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part Square, TPO 3-Square -245.0 NEW ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 133 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing granule -surfaced modified bitumen over struct. Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer EverGuard TPO / TPO 6- R-121. concrete deck EnergyGuard Ultra GAF 2-Part of base insulation GAF 2-Part Square, TPO 3-Square _270.0 R-122. Existing smooth-orgranule-surfaced BUR orsmooth-or Min. 1-inch EnergyGuard Polyiso Insulation, LRF-M None N/A EverGuard TPO /TPO 6- granule -surfaced modified bitumen EnergyGuard Ultra Square, TPO 3-Square -45.0 Existing smooth- or granule -surfaced BUR; smooth -or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / TPO 6- R-123. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M of base insulation LRF-M Square, TPO 3-Square -110.0 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-M, 6- (Optional) Additional layer LRF-M, 6- EverGuard TPO / TPO 6- R-124. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. Square, TPO 3-Square -157.5 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-M, 4- (Optional) Additional layer LRF-M, 4- EverGuard TPO / TPO 6- R-125. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. Square, TPO 3-Square _200.0 gravel, overstructural concrete deck Min. 0.5-inch EnergyGuard Existing smooth-orgranule-surfaced BUR or smooth- or (Optional) 0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, EverGuard TPO / TPO 6- R-126. granule -surfaced modified bitumen over structural Insulation or min. Min. 1.5-inch EnergyGuard LRF-M EnergyGuard HD Polyiso LRF-M 75.0 concrete deck RH Insulation, EnergyGuard HD Square, TPO 3-Square Plus Polyiso Insulation Existing smooth- or granule -surfaced BUR or smooth- or Min. 0.5-inch EnergyGuard Polyiso Insulation, Min. inch Structodek EverGuard TPO / TPO 6- R-127. granule -surfaced modified bitumen over structural LRF-M High Density Fiberboard Den LRF-M 82 5 concrete deck EnergyGuard Ultra Roof Insulation Square, TPO 3-Square Existing smooth-orgranule-surfaced BUR orsmooth-or Min.0.5-inch EnergyGuard Polyiso Insulation, Min.0.5-inch Structodek EverGuard TPO /TPO 6- R-128. granule -surfaced modified bitumen over structural LRF-M High Density Fiberboard LRF-M 82.5 concrete deck EnergyGuard Ultra gy Roof Insulation Square, TPO 3-Square (Optional) Min. 0.25-inch Existing smooth-orgranule-surfaced BUR orsmooth- or Min. 0.5-inch EnergyGuard Polyiso Insulation, DensDeck Prime or EverGuard TPO / TPO 6- R-129. granule -surfaced modified bitumen over structural EnergyGuard Ultra LRF-M SECUROCK Gypsum -Fiber LRF-M Square, TPO 3-Square 75.0 concrete deck Roof Board (Optional when using base Existing smooth- orgranule-surfaced BUR or smooth- or (Optional when using coverboard) Min. 0.5-inch insulation) Min. 0.25-inch EverGuard TPO / TPO 6- R-130. granule -surfaced SBS or granule -surfaced APP modified EnergyGuard Polyiso Insulation, EnergyGuard LRF-M DensDeck Prime or LRF-M -225.0 bitumen over structural concrete deck Ultra or min. 1.5-inch EnergyGuard RH SECUROCK Gypsum -Fiber Square, TPO 3-Square Roof Board Existing smooth- orgranule-surfaced BUR or smooth -or Min. 1-inch EnergyGuard Polyiso Insulation, tLRF-.F EverGuard TPO / TPO 6- R-131. granule -surfaced modified bitumen g EnergyGuard Ultra None N/A Square, TPO 3-Square -45.0 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 134 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / TPO 6- R-132. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF of base insulation LRF-XF Square, TPO 3-Square -110.0 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced LRF-XF, 6- (Optional) Additional layer LRF-XF, 6- EverGuard TPO / TPO 6- R-133. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. Square, TPO 3-Square -157.5 gravel, over structural concrete deck Existing smooth -or granule -surfaced BUR; smooth -or Min. 0.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers EverGuard TPO / TPO 6- R-134. granule -surfaced SB5 or APP modified bitumen over EnergyGuard Ultra or EnergyGuard RH LRF-XF base insulation LRF-XF Square, TPO 3-Square -180.0 structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-XF, 4- (Optional) Additional layer LRF-XF, 4- EverGuard TPO / TPO 6- R-135. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. Square, TPO 3-Square _200.0 gravel, over structural concrete deck Existing smooth -surface modified bitumen over struct. Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer EverGuard TPO / TPO 6- R-136. concrete deck EnergyGuard Ultra LRF-XF of base insulation LRF-XF Square, TPO 3-Square 222 5 Existing smooth -surface BUR or granule -surface modified Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer EverGuard TPO / TPO 6- R-137. bitumen over struct. concrete deck EnergyGuard Ultra LRF-XF of base insulation LRF-XF Square, TPO 3-Square -245.0 Existing granule -surfaced modified bitumen over struct. Min. 1.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layer EverGuard TPO / TPO 6- R-138. concrete deck EnergyGuard Ultra LRF-XF of base insulation LRF-XF Square, TPO 3-Square -270.0 Existing smooth -or granule -surfaced BUR; smooth -or Min.1-inch EnergyGuardPolyisoInsulation, EverGuard TPO /TPO 6- R-139. granule -surfaced SBS modified bitumen or granule- OB500 None N/A 45.0 surfaced APP modified bitumen EnergyGuard Ultra Square, TPO 3-Square Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / TPO 6- R-140. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation OB500 of base insulation OBS00 Square, TPO 3-Square -110.0 gravel, over structural concrete deck Existing smooth -or granule -surfaced BUR; smooth -or (Optional) Additional layer EverGuard TPO / TPO 6- R-141. granule -surfaced SBS modified bitumen or granule- Min. 1.5-inch EnergyGuard Ultra OB500 OB500 -120.0 surfaced APP modified bitumen over struct. concrete deck of base insulation Square, TPO 3-Square Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced OB500, 6- (Optional) Additional layer OB500, 6- EverGuard TPO / TPO 6- R-142. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. Square, TPO 3-Square _157.5 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced OB500, 4- (Optional) Additional layer OB500, 4- EverGuard TPO / TPO 6- R-143. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. Square, TPO 3-Square -200.0 gravel, over structural concrete deck NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 135 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Min. 0.5-inch EnergyGuard Existing smooth- orgranule-surfaced BUR; smooth -or (Optional) 0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, O EverGuard rd / TPO 6- TPO / TP R-144. granule -surfaced SBS modified bitumen or granule- Insulation or min. Min. 1.5-inch EnergyGuard OB500 EnergyGuard HD Polyiso OB500 97.5 surfaced APP modified bitumen over struct. concrete deck RH Insulation, EnergyGuard HD Square, uare Plus Polyiso Insulation Existing smooth- orgranule-surfaced BUR; smooth -or Min. 0.5-inch EnergyGuard Polyiso Insulation, Min. 0.5-inch Structodek EverGuard TPO / TPO 5- R-145. granule -surfaced SBS modified bitumen or granule- OB500 High Density Fiberboard OB500 82.5 surfaced APP modified bitumen over struct. concrete deck EnergyGuard Ultra Roof Insulation Square, TPO 3-Square (Optional) Min. 1.5-inch EnergyGuard RA, Existing smooth- orgranule-surfaced BUR; smooth- or EnergyGuard RH or EnergyGuard RN, min. 2- Min. 0.25-Inch DensDeck EverGuard TPO / TPO 6- R-146. granule -surfaced SBS modified bitumen or granule- inch, min. 2.0 pcf, Insulfoam EPS or min. 1.5- OB500 Prime or SECUROCK OB500 Square, TPO 3-Square 45 0 surfaced APP modified bitumen Gypsum -Fiber Roof Board inchlnsulfoam (Optional when using brae Existing smooth-orgranule-surfaced BUR; smooth -or (Optional when using coverboard) Min. 0.5-inch insulation) Min. 0.25-inch EverGuard TPO / TPO 6- R-147. granule -surfaced SBS or APP modified bitumen over EnergyGuard Polyiso Insulation, EnergyGuard OB500 DensDeck Prime or OB500 -225.0 structural concrete deck Ultra or min. 1.5-inch EnergyGuard RH SECUROCK Gypsum -Fiber Square, TPO 3-Square Roof Board EverGuard TPO / EverGuard TPO Quick Spray: R-148. Existing smooth- orgranule-surfaced BUR or smooth -or Min. 1-inch EnergyGuard Polyiso Insulation GAF 2-Part None N/A EverGuard TPO/TPO QSA -45.0 granule -surfaced modified bitumen Existing smooth- or granule -surfaced BUR; smooth- or R-149. granule surfaced SBS modified bitumen or gravel -surfaced Min1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional) Additional layer GAF 2-Part EverGuard TPO / TPO QSA -82.5 BUR, brushed/spudded and vacuumed to remove loose . of base insulation gravel, over structural concrete deck Existing smooth- orgranule-surfaced BUR or smooth -or Min. 1.5-inch EnergyGuard RA, EnergyGuard RH Min. 0.25-inch DensDeck R-150. granule -surfaced SBS or granule -surfaced APP modified or EnergyGuard RN or Min. 1.5-inch thick, min. GAF 2-Part GAF 2-Part EverGuard TPO / TPO QSA -130.0 bitumen over structural concrete deck 1.5 pcf Insulfoam EPS prime Existing smooth- or granule -surfaced BUR or smooth- or Min. 0.25-inch DensDeck R-151. granule -surfaced SBS orgranule-surfaced APP modified Min. 1.5-inch thick, min. 1.25 pcf Insulfoam EPS GAF 2-Part GAF 2-Part EverGuard TPO / TPO QSA -87.5 bitumen over structural concrete deck prime R-152. Existing smooth- orgranule-surfaced BUR or smooth- or Min. 1-inch EnergyGuard Polyiso Insulation LRF-M None N/A EverGuard TPO / TPO QSA -45.0 granule -surfaced modified bitumen Existing smooth- or granule -surfaced BUR; smooth- or R-153. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional) Additional layer LRF-M EverGuard TPO / TPO QSA -82.5 BUR, brushed/spudded and vacuumed to remove loose of base insulation gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR or smooth- or (Optional) Min. 0.25-inch R-154. granule -surfaced modified bitumen over structural Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M LRF-M EverGuard TPO / TPO QSA concrete deck DensDeck Prime NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02819 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 136 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth- orgranule-surfaced BUR or smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso Min. 0.25-inch DensDeck R-155. granule -surfaced SB5 or granule -surfaced APP modified Insulation, EnergyGuard Ultra or min. 1.5-inch LRF-M LRF-M EverGuard TPO / TPO QSA -225.0 bitumen over structural concrete deck EnergyGuard RH Prime Existing smooth-orgranule-surfaced BUR orsmooth-or (Optional) Min. 0.5-inch EnergyGuard Polyiso Min. 0.25-inch SECUROCK R-156. granule -surfaced modified bitumen over structural LRF-M LRF-M EverGuard TPO / TPO QSA -75.0 concrete deck Insulation or min. 1.5-inch EnergyGuard RH Gypsum -Fiber Roof Board Existing smooth-orgranule-surfaced BUR orsmooth- or (Optional) Min. 0.5-inch EnergyGuard Polyiso EnergyGuard R-157. granule -surfaced modified bitumen over structural Insulation or min. Min. 1.5-inch EnergyGuard LRF-M HD Polyiso HD Polyiso Insulation, In LRF-M EverGuard TPO / TPO QSA -75.0 concrete deck RH EnergyGuard HD Plus Polyiso Insulation R-158. Existing smooth- or granule -surfaced BUR or smooth- or Min. 1-inch EnergyGuard Polyiso Insulation LRF-XF None N/A EverGuard TPO / TPO QSA -45.0 granule -surfaced modified bitumen Existing smooth- or granule -surfaced BUR; smooth- or R-159. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional) Additional layer LRF-XF EverGuard TPO / TPO QSA -82.5 BUR, brushed/spudded and vacuumed to remove loose of base insulation gravel, over structural concrete deck Existing smooth- orgranule-surfaced BUR or smooth- or Min. 1.5-inch EnergyGuard RA or EnergyGuard Min. 0.25-inch DensDeck R-160. granule -surfaced SB5 or granule -surfaced APP modified LRF-XF LRF-XF EverGuard TPO / TPO QSA -130.0 bitumen over structural concrete deck RH prime Existing smooth- or granule -surfaced BUR; smooth- or R-161. granule -surfaced SBS modified bitumen or granule- Min. 1-inch EnergyGuard Polyiso Insulation OB500 None N/A EverGuard TPO / TPO QSA -45.0 surfaced APP modified bitumen Existing smooth- or granule -surfaced BUR; smooth- or R-162. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional) Additional layer OB500 EverGuard TPO / TPO QSA -82.5 BUR, brushed/spudded and vacuumed to remove loose of base insulation gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or Min. 0.25-inch DensDeck R-163. granule -surfaced SBS modified bitumen or granule- Min. 1.5-inchlnsulfoam OB500 OB5o0 EverGuard TPO / TPO QSA -45.0 surfaced APP modified bitumen Prime Existing smooth- orgranule-surfaced BUR; smooth -or (Optional) Min. 1.5-inch EnergyGuard RA, Min. 0.25-inch DensDeck R-164. granule -surfaced SB5 modified bitumen or granule- EnergyGuard RH, EnergyGuard RN , min. 2-inch, OB500 OB500 EverGuard TPO / TPO QSA -120.0 surfaced APP modified bitumen over struct. concrete deck min. 2.0 pcf, Insulfoam EPS prime Existing smooth- orgranule-surfaced BUR; smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso Min. 0.25-inch DensDeck R-165. granule -surfaced SB5 or APP modified bitumen over Insulation, EnergyGuard Ultra or min. 1.5-inch OB500 OB500 EverGuard TPO / TPO QSA -225.0 structural concrete deck EnergyGuard RH Prime Existing smooth- or granule -surfaced BUR; smooth- or R-166. granule -surfaced SBS modified bitumen or granule- (Optional) Min. 0.5-inch EnergyGuard Polyiso OB500 Min. 0.25-inch SECUROCK OB500 EverGuard TPO / TPO QSA -97.5 surfaced APP modified bitumen over structural concrete Insulation or min. 1.5-inch EnergyGuard RH Gypsum -Fiber Roof Board deck NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 137 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Attach Attach Roof Cover (Note 15) Psfl oem No.Type Type (Notes 6,7,8) (Notes 6,7,8) Min. 0.5-inch EnergyGuard Existing smooth- orgranule-surfaced BUR; smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso HD Polyiso Insulation, R-167. granule -surfaced SBS modified bitumen or granule- Insulation or min. 1.5-inch EnergyGuard RH OB500 EnergyGuard HD Plus OB500 EverGuard TPO / TPO QSA -97.5 surfaced APP modified bitumen over struct. concrete deck Polyiso Insulation EverGuard TPO / EverGuard TPO Quick Spray LV SO: R-168. Existing smooth-orgranule-surfaced BUR orsmooth- or Min. 1-inch EnergyGuard Polyiso Insulation GAF 2-Part None N/A EverGuard TPO / TPO QSA 45 0 granule -surfaced modified bitumen LV50 Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / TPO QSA R-169. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part of base insulation GAF 2-Part LV50 _110.0 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard TPO / TPO QSA R-170. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation 5-inch o.c. of base insulation 6-inch o.c. LV50 _157.5 gravel, over structural concrete deck Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Additional layers EverGuard TPO TPO QSA R-171. granule -surfaced SBS or APP modified bitumen over Min. 0.5-inch EnergyGuard Polyiso Insulation GAF 2-Part GAF 2-Part -180.0 structural concrete deck base insulation LV50 Existing smooth- or granule -surfaced BUR; smooth- or R-172. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard TPO / TPO QSA _200.0 BUR, brushed/spudded and vacuumed to remove loose 4-inch o.c. of base insulation 4-inch o.c. LV50 gravel, overstructural concrete deck Existing smooth -surface modified bitumen over struct. (Optional) Additional layer EverGuard TPO / TPO QSA R-173. concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part of base insulation GAF 2-Part LV50 222 5 Existing smooth -surface BUR or granule -surface modified (Optional) Additional layer EveGuard TPO / TPO QSA R-174. bitumen overstruct. concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part of base insulation GAF 2-Part LV5r 0 _245.0 Existing granule -surfaced modified bitumen overstruct. (Optional) Additional layer EverGuard TPO / TPO QSA R-175. concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part of base insulation GAF 2-Part LV50 -270.0 Existing smooth- orgranule-surfaced BUR or smooth -or Min. 0.25-inch Min. 0.25- EverGuard TPO TPO QSA R-176. granule -surfaced SB5 or granule -surfaced APP modified Min. 1.5-inch thick, min. 1.25 pcf Insulfoam EPS GAF 2-Part GAF 2-Part 87.5 bitumen overstructural concrete deck inch DensDeck Prime LV50 Existing smooth-orgranule-surfaced BUR orsmooth-or (Optional) Min. 1.5-inch EnergyGuard RA, Min. 0.25- Min. 0.25-inch 5-inchnsDeck EverGuard TPO TPO QSA R-177. granule -surfaced SBS orgranule-surfaced APP modified EnergyGuard RH or EnergyGuard RN or Min. GAF 2-Part GAF 2-Part -130.0 bitumen overstructural concrete deck 1.5-inch thick, min. 1.5 pcf Insulfoam EPS inch De Prime LV50 Existing smooth- orgranule-surfaced BUR or smooth -or Min. 0.25-inch SECUROCK EverGuard TPO TPO QSA R-178. granule -surfaced SBS or granule -surfaced APP modified Min. 1.5-inch thick, min. 1.25 pcf Insulfoam EPS GAF 2-Part GAF 2-Part 87.5 bitumen overstructural concrete deck Gypsum -Fiber Roof Board LV50 Existing smooth-orgranule-surfaced BUR orsmooth- or One or more layers, min. 1.5-inch thick, min. Min. 0.25-inch SECUROCK EverGuard TPO / TPO QSA R-179. granule -surfaced SB5 or granule -surfaced APP modified 1.5 pcf Insulfoam EPS GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part LV50 -180.0 bitumen overstructural concrete deck NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02819 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 138 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth -surfaced modified bitumen over struct. (Optional) Min. 2-inch EnergyGuard RA, Min. EverGuard TPO / TPO QSA R-180. EnergyGuard RH or EnergyGuard RN or min. GAF 2-Part GAF 2-Part 222 5 concrete deck 1.5-inch thick, min. 2.0 pcf Insulfoam EPS um -Finch Roof Board Gypsum -Fiber Roof Board LV50 Existing smooth -surface BUR or granule -surface modified One or more layers, min. 1.5-inch thick, min. Min. 0.25-inch SECUROCK EverGuard TPO / TPO QSA R-181. bitumen over struct. concrete deck 2.0 pcf Insulfoam EPS GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part LV50 -240.0 R-182. Existing smooth -surface BUR or granule -surface modified Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part None N/A EverGuard TPO / TPO QSA bitumen over struct. concrete deck Board LV50 _245.0 Existing smooth -surface BUR or granule surface modified Min. 2-inch EnergyGuard RA, EnergyGuard RH Min. 0.25-inch SECUROCK EverGuard TPO / TPO QSA R-183. bitumen over struct. concrete deck or EnergyGuard RN GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part LV50 -247.5 R-184. Existing smooth- or granule -surfaced BUR or smooth- or Min1-inch EnerGuard Pol . gyyiso Insulation LRF-M None N/A EverGuard TPO / TPO QSA -45.0 granule -surfaced modified bitumen LV50 Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / TPO QSA R-185. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M of base insulation LRF-M LV50 _110.0 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-M, 6- (Optional) Additional layer LRF-M, 6- EverGuard TPO / TPO QSA R-186. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base Insulation inch o.c. LV50 _157.5 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced LRF-M, 4- (Optional) Additional layer LRF-M, 4- EverGuard TPO / TPO QSA R-187. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. LV50 -200.0 gravel, over structural concrete deck Existing smooth- orgranule-surfaced BUR or smooth- or Min. 0.5-inch EnergyGuard Polyiso Insulation, Min. 0.25-inch DensDeck EverGuard TPO / TPO QSA R-188. granule -surfaced modified bitumen over structural EnergyGuard Ultra LRF-M prime LRF-M LV50 75.0 concrete deck Existing smooth-orgranule-surfaced BUR orsmooth- or (Optional) Min. 0.5-inch EnergyGuard Polyiso Min. 0.25-inch DensDeck EverGuard TPO / TPO QSA R-189. granule -surfaced SBS or granule -surfaced APP modified Insulation, EnergyGuard Ultra or min. 1.5-inch LRF-M LRF-M -202.5 bitumen over structural concrete deck EnergyGuard RH prime LV50 Existing smooth- orgranule-surfaced BUR orsmooth-or (Optional) Min. 0.25-inch EverGuard TPO TPO QSA R-190. granule -surfaced modified bitumen over structural Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M SECUROCK Gypsum -Fiber LRF-M 75.0 concrete deck Roof Board LV50 (Optional when using base Existing smooth- orgranule-surfaced BUR or smooth- or (Optional when using coverboard) Min. 0.5-inch insulation) Min. 0.25-inch EverGuard TPO / TPO QSA R-191. granule -surfaced SBS or granule -surfaced APP modified EnergyGuard Polyiso Insulation LRF-M SECUROCK Gypsum -Fiber LRF-M LV50 -225.0 bitumen over structural concrete deck Roof Board Min. 0.5-inch EnergyGuard Existing smooth- orgranule-surfaced BUR or smooth -or (Optional)0.5-inch EnergyGuard Polyiso HD Polyiso Insulation, EverGuard TPO / TPO QSA R-192. granule -surfaced modified bitumen over structural Insulation or min. Min. 1.5-inch EnergyGuard LRF-M LRF-M 75 0 concrete deck RH EnergyGuard HD Plus LV50 Polyiso Insulation NEW ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 139 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) R-193. Existing smooth-orgranule-surfaced BUR orsmooth-or Min1-inch EnergyGuard Polyiso Insulation LRF-XF None N/A EverGuard TPO TPO _45.0 granule -surfaced modified bitumen LV50 Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / TPO QSA R-194. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF of base insulation LRF-XF LV50 _110.0 gravel, overstructural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or R-195. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF, 6- (Optional) Additional layer LRF-XF, 6- EverGuard TPO / TPO QSA _157.5 BUR, brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. LV50 gravel, overstructural concrete deck Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Additional layers EverGuard TPO TPO QSA R-196. granule -surfaced SBS or APP modified bitumen over Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-XF base insulation LRF-XF LV50 -180.0 structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or R-197. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF, 4- (Optional) Additional layer LRF-XF, 4- EverGuard TPO / TPO QSA _200.0 BUR, brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. LV50 gravel, over structural concrete deck Existing smooth -surface modified bitumen over struct. (Optional) Additional layer EverGuard TPO / TPO QSA R-198. concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF of base insulation LRF-XF LV50 222 5 Existing smooth -surface BUR or granule -surface modified (Optional) Additional layer EverGuard TPO / TPO QSA R-199. bitumen over struct. concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF of base insulation LRF-XF LV50 _245.0 R-200. Existing granule -surfaced modified bitumen over struct. Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional) Additional layer LRF-XF EverGuard TPO / TPO QSA -270.0 concrete deck of base insulation LV50 Existing smooth- orgranule-surfaced BUR or smooth- or (Optional) Min. 1.5-inch EnergyGuard RA or Min. 0.25-inch DensDeck EverGuard TPO / TPO QSA R-201. granule -surfaced SB5 or granule -surfaced APP modified EnergyGuard RH LRF-XF prime LRF-XF LV50 -130.0 bitumen over structural concrete deck Existing smooth -surfaced modified bitumen over struct. (Optional) Min. 2-inch EnergyGuard RA or Min. 0.25-inch SECUROCK EverGuard TPO / TPO QSA R 202 concrete deck EnergyGuard RH LRF-XF Gypsum -Fiber Roof Board LRF-XF LV50 222 5 R-203. Existing smooth -surface BUR or granule -surface modified Min. 0.25-inch SECUROCK Gypsum -Fiber Roof LRF-XF None N/A EverGuard TPO / TPO QSA bitumen over struct. concrete deck Board LV50 -245.0 Existing smooth -surface BUR or granule surface modified Min. 2-inch EnergyGuard RA or EnergyGuard Min. 0.25-inch SECUROCK EverGuard TPO / TPO QSA R-204. bitumen over struct. concrete deck RH LRF-XF Gypsum -Fiber Roof Board LRF-XF LV50 -247.5 Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO / TPO QSA R-205. granule -surfaced SBS modified bitumen or granule- Min. 1-inch EnergyGuard Polyiso Insulation OB500 None N/A -45.0 surfaced APP modified bitumen LV50 Existing smooth- or granule -surfaced BUR; smooth- or R-206. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional) Additional layer OB500 EverGuard TPO / TPO QSA -110.0 BUR, brushed/spudded and vacuumed to remove loose of base insulation LV50 gravel, over structural concrete deck NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 140 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced OB500, 6- (Optional) Additional layer OB500, 6- EverGuard TPO / TPO QSA R 207 BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. LV50 _157.5 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced OB500, 4- (Optional) Additional layer OB500, 4- EverGuard TPO / TPO QSA R 208 BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. LV50 -200.0 gravel, over structural concrete deck Existing smooth -or granule -surfaced BUR; smooth -or Min. 0.25-inch DensDeck EverGuard TPO/TPO QSA R-209. granule -surfaced SB5 modified bitumen or granule- surfaced APP modified bitumen Min. 1.5-inch Insulfoam OB500 Prime OB500 LV50 -45.0 Existing smooth -or granule -surfaced BUR; smooth -or Min. 1.5-inch EnergyGuard RA, EnergyGuard Min. 0.25-inch DensDeck EverGuard TPO / TPO QSA R-210. granule -surfaced SBS modified bitumen or granule- RH, EnergyGuard RN, min. 2-inch, min. 2.0 pcf, OB500 06500 -120.0 surfaced APP modified bitumen over struct. concrete deck Insulfoam EPS Prime LV50 Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso Min. 0.25-inch DensDeck EverGuard TPO / TPO QSA R-211. granule -surfaced SBS or APP modified bitumen over Insulation, EnergyGuard Ultra or min. 1.5-inch OB500 OB500 -202.5 structural concrete deck EnergyGuard RH prime LV50 Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Min. 1.5-inch EnergyGuard RA, Min. 0.25-inch SECUROCK EverGuard TPO / TPO QSA R-212. granule -surfaced SBS modified bitumen or granule- EnergyGuard RH, EnergyGuard RN , min. 2-inch, OB500 08500 -120.0 surfaced APP modified bitumen over struct. concrete deck min. 2.0 pcf, Insulfoam EPS Gypsum -Fiber Roof Board LV50 Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso Min. 0.25-inch SECUROCK EverGuard TPO / TPO QSA R-213. granule -surfaced SBS or APP modified bitumen over Insulation, EnergyGuard Ultra or min. 1.5-inch OB500 Gypsum -Fiber Roof Board OB500 LV50 -225.0 structural concrete deck EnergyGuard RH Min. 0.5-inch EnergyGuard Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso HD Polyiso Insulation, EverGuard TPO / TPO QSA R-214. granule -surfaced SBS modified bitumen or granule- Insulation or min. 1.5-inch EnergyGuard RH OB500 EnergyGuard HD Plus OB500 LV50 97.5 surfaced APP modified bitumen over struct. concrete deck Polyiso Insulation EverGuard TPO in FastLayn TPO Adhesive: (Optional) Min. 0.25-inch EverGuard TPO / FastLayn R-215. Existing asphalt BUR or mineral surface cap sheet Min. 1.5-inch EnergyGuard RA hot asphalt hot asphalt -45.0 DensDeck Prime TPO Adhesive R-216. Existing smooth -or granule -surfaced BUR or smooth- or Min. 1-inch EnergyGuard Polyiso Insulation GAF 2-Part None N/A EverGuard TPO / FastLayn -45.0 granule -surfaced modified bitumen TPO Adhesive Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / FastLayn R-217. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part of base insulation GAF 2-Part TPO Adhesive -110.0 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard TPO / FastLayn R-218. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation 6-inch o.c. of base insulation 6-inch o.c. TPO Adhesive -157.5 gravel, over structural concrete deck NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 141 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard TPO / FastLayn R-219. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation 4-inch o.c. of base insulation 4-inch o.c. TPO Adhesive -200.0 gravel, overstructural concrete deck Existing smooth- orgranule-surfaced BUR; smooth -or (Optional) Additional layers EverGuard TPO / FastLayn R-220. granule -surfaced SB5 or APP modified bitumen over Min. 0.5-inch EnergyGuard Polyiso Insulation GAF 2-Part GAF 2-Part -180.0 structural concrete deck base insulation TPO Adhesive Existing smooth -surfaced modified bitumen over structural (Optional) Additional layer EverGuard TPO / FastLayn R-221. concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part of base insulation GAF 2-Part TPO Adhesive 222 5 (Optional) Additional layer EverGuard TPO / FastLayn R-222. Existing smooth -surface BUR over structural concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part GAF 2-Part -262.5 of base insulation TPO Adhesive Existing granule -surface modified bitumen over structural (Optional) Additional layer EverGuard TPO / FastLayn R-223. concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part of base insulation GAF 2-Part TPO Adhesive -270.0 Existing smooth- orgranule-surfaced BUR or smooth- or Min. 1.5-inch EnergyGuard RA, EnergyGuard RH Min. 0.25-inch DensDeck EverGuard TPO / FastLayn R-224. granule -surfaced SBS or granule -surfaced APP modified or EnergyGuard RN or Min. 1.5-inch thick, min. GAF 2-Part GAF 2-Part -130.0 bitumen overstructural concrete deck 1.5 pcf Insulfoam EPS prime TPO Adhesive Existing smooth- orgranule-surfaced BUR or smooth -or Min. 0.25-inch DensDeck EverGuard TPO / Eve EveFastLayn R-225. granule -surfaced SBS or granule -surfaced APP modified Min. 1.5-inch thick, min. 1.25 pcf Insulfoam EPS GAF 2-Part Prime or SECUROCK GAF 2-Part 87.5 bitumen overstructural concrete deck Gypsum -Fiber Roof Board TPO Adhesive Existing smooth- orgranule-surfaced BUR or smooth- or One or more layers, min. 1.5-inch thick, min. Min. 0.25-inch SECUROCK EverGuard TPO / FastLayn R-226. granule -surfaced SBS or granule -surfaced APP modified 1.5 pcf Insulfoam EPS GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part TPO Adhesive -180.0 bitumen overstructural concrete deck Existing smooth -surfaced modified bitumen over structural (Optional) Min. 2-inch EnergyGuard RA, Min. 0.25-inch SECUROCK EverGuard TPO / FastLayn R 227 concrete deck EnergyGuard RH or EnergyGuard RN or min. GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part TPO Adhesive 222 5 1.5-inch thick, min. 2.0 pcf Insulfoam EPS Existing smooth -surface BUR or granule -surface modified One or more layers, min. 1.5-inch thick, min. Min. 0.25-inch SECUROCK EverGuard TPO / FastLayn R-228. bitumen overstructural concrete deck 2.0 pcf Insulfoam EPS GA F 2-Part Gypsum -Fiber Roof Board GAF 2-Part TPO Adhesive -240.0 R 229 Existing smooth -surface BUR or granule -surface modified Min. 0.25-inch SECUROCK Gypsum -Fiber Roof GAF 2-Part None N/A EverGuard TPO / FastLayn bitumen overstructural concrete deck Board TPO Adhesive _245.0 Existing smooth -surface BUR or granule surface modified Min. 2-inch EnergyGuard RA, EnergyGuard RH Min. 0.25-inch SECUROCK EverGuard TPO / FastLayn R-230. bitumen overstructural concrete deck or EnergyGuard RN GAF 2-Part Gypsum -Fiber Roof Board GAF 2-Part TPO Adhesive -247.5 R-231. Existing smooth- orgranule-surfaced BUR or smooth -or Min.1-inch EnergyGuard Polyiso Insulation LRF-M None N/A EverGuard TPO FastLayn -45.0 granule -surfaced modified bitumen TPO Adhesive Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / FastLayn R-232. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M of base insulation LRF-M TPO Adhesive _110.0 gravel, over structural concrete deck NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 142 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced LRF-M, 6- (Optional) Additional layer LRF-M, 6- EverGuard TPO / FastLayn R-233. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch O.C. of base insulation inch o.c. TPO Adhesive -157.5 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced LRF-M, 4- (Optional) Additional layer LRF-M, 4- EverGuard TPO / FastLayn R-234. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. TPO Adhesive -200.0 gravel, over structural concrete deck Existing smooth- orgranule-surfaced BUR or smooth- or (Optional) Min. 0.5-inch EnergyGuard Polyiso Min. 0.5-inch EnergyGuard EverGuard TPO / FastLayn R-235. granule -surfaced modified bitumen over structural Insulation or min. 1.5-inch EnergyGuard RH LRF-M HD Polyiso Insulation LRF-M TPO Adhesive -75.0 concrete deck (Optional) Min. 0.25-inch Existing smooth- orgranule-surfaced BUR or smooth- or DensDeck Prime or EverGuard TPO / FastLayn R-236. granule -surfaced modified bitumen over structural Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M SECUROCK Gypsum -Fiber LRF-M TPO Adhesive -75.0 concrete deck Roof Board (Optional when using base Existing smooth- orgranule-surfaced BUR or smooth- or (Optional when using coverboard)Min. 0.5-inch insulation) Min. 0.25-inch EverGuard TPO / FastLayn R-237. granule -surfaced SB5 or granule -surfaced APP modified bitumen over structural concrete deck EnergyGuard Polyiso Insulation LRF-M DensDeck Prime or SECUROCK Gypsum -Fiber LRF-M TPO Adhesive -225.0 Roof Board R-238. Existing smooth- orgranule-surfaced BUR or smooth- or Min. 1-inch EnergyGuard Polyiso Insulation LRF-XF None N/A EverGuard TPO / FastLayn 45 0 granule -surfaced modified bitumen TPO Adhesive Existing smooth- or granule -surfaced BUR; smooth- or R-239. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional) Additional layer LRF-XF EverGuard TPO / FastLayn -110.0 BUR, brushed/spudded and vacuumed to remove loose of base insulation TPO Adhesive gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-XF, 6- (Optional) Additional layer LRF-XF, 6- EverGuard TPO / FastLayn R-240. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch O.C. of base insulation inch o.c. TPO Adhesive _157.5 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-XF, 4- (Optional) Additional layer LRF-XF, 4- EverGuard TPO / FastLayn R-241. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. TPO Adhesive _200.0 gravel, over structural concrete deck Existing smooth- orgranule-surfaced BUR; smooth -or (Optional) Additional layers EverGuard TPO / FastLayn R-242. granule -surfaced SBS or APP modified bitumen over Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-XF LRF-XF -180.0 structural concrete deck base insulation TPO Adhesive Existing smooth -surfaced modified bitumen over structural (Optional) Additional layer EverGuard TPO / FastLayn R-243. concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF of base insulation LRF-XF TPO Adhesive 222 5 (Optional) Additional layer EverGuard TPO / FastLayn R-244. Existing smooth -surface BUR over structural concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF LRF-XF -262.5 of base insulation I I TPO Adhesive NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization H32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 143 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing granule -surface modified bitumen over structural (Optional) Additional layer EverGuard TPO / FastLayn R-245. concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF of base insulation LRF-XF TPO Adhesive -270.0 Existing smooth- orgranule-surfaced BUR or smooth- or Min. 1.5-inch EnergyGuard RA or EnergyGuard Min. 0.25-inch DensDeck EverGuard TPO / FastLayn R-246. granule -surfaced SBS or granule -surfaced APP modified RH LRF-XF prime LRF-XF TPO Adhesive -130.0 bitumen over structural concrete deck Existing smooth -surfaced modified bitumen over structural (Optional) Min. 2-inch EnergyGuard RA or Min. 0.25-inch SECUROCK EverGuard TPO / FastLayn R-247. concrete deck EnergyGuard RH LRF-XF Gypsum -Fiber Roof Board LRF-XF TPO Adhesive 222.5 R 248 Existing smooth -surface BUR or granule -surface modified Min. 0.25-inch SECUROCK Gypsum -Fiber Roof LRF-XF None N/A EverGuard TPO / FastLayn bitumen over structural concrete deck Board TPO Adhesive _245.0 Existing smooth -surface BUR or granule surface modified Min. 2-inch EnergyGuard RA or EnergyGuard Min. 0.25-inch SECUROCK EverGuard TPO / FastLayn R-249. bitumen over structural concrete deck RH LRF-XF Gypsum -Fiber Roof Board LRF-XF TPO Adhesive -247.5 Existing smooth- orgranule-surfaced BUR; smooth -or EverGuard TPO / FastLayn R-250. granule -surfaced SBS modified bitumen or granule- Min. 1-inch EnergyGuard Polyiso Insulation OB500 None N/A -45.0 surfaced APP modified bitumen TPO Adhesive Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO / FastLayn R-251. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation OB500 of base insulation OB500 TPO Adhesive _110.0 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or R-252. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation OB500, 6- (Optional) Additional layer OB500, 6- EverGuard TPO / FastLayn _157.5 BUR, brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. TPO Adhesive gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced OB500, 4- (Optional) Additional layer OB500, 4- EverGuard TPO / FastLayn R-253. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. TPO Adhesive _200.0 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule -surfaced SBS modified bitumen or granule- (Optional) Min. 0.5-inch EnergyGuard Polyiso Min. 0.5-inch EnergyGuard EverGuard TPO / FastLayn R-254. surfaced APP modified bitumen over structural concrete Insulation or min. 1.5-inch EnergyGuard RH OB500 HD Polyiso Insulation OB500 TPO Adhesive 97.5 deck Existing smooth- orgranule-surfaced BUR; smooth -or Min. 0.25-inch DensDeck EverGuard TPO / FastLayn R-255. granule -surfaced SBS modified bitumen or granule- Min. 1.5-inch , Insulfoam EPS OB500 OB500 45.0 surfaced APP modified bitumen Prime TPO Adhesive Existing smooth- orgranule-surfaced BUR; smooth -or (Optional) Min. 1.5-inch EnergyGuard RA, Min. 0.25-inch DensDeck granule -surfaced SBS modified bitumen or granule- EnergyGuard RH, EnergyGuard RN , min. 2-inch, EverGuard TPO / FastLayn R-256. surfaced APP modified bitumen over structural concrete min. 2.0 pcf, Insulfoam EPS or min. 1-inch 06500 Prime or SECUROCK OB500 TPO Adhesive -120.0 deck Foamular 250 Gypsum -Fiber Roof Board (Optional when using base Existing smooth-orgranule-surfaced BUR; smooth -or (Optional when using coverboard) Min. 0.5-inch insulation) Min. 0.25-inch EverGuard TPO / FastLayn R-257. granule -surfaced SBS or APP modified bitumen over structural concrete deck nergyuaroysonsuaon EnergyGuard Polyiso Insulation OB500 DensDeck Prime or SECUROCK Gypsum -Fiber OB500 TPO Adhesive -225.0 Roof Board NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 144 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer y System Substrate (Notes 1 & 12) Attach Attach Roof Cover (Note 15) ;p� Type Type (Notes 6,7,8) (Notes 6,7,8) EverGuard TPO Fleece -Back Membrane in EverGuard WB381 Bonding Adhesive: R-258. Existing smooth- orgranule-surfaced BUR or smooth -or Min. 1-inch EnergyGuard Polyiso Insulation, GAF 2-Part None N/A EverGuard TPO Fleece -Back granule -surfaced modified bitumen EnergyGuard Ultra Membrane / WB181 -45.0 Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO Fleece -Back R-259. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part of base insulation GAF 2-Part Membrane / WB181 -110.0 gravel, overstructural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard TPO Fleece -Back R-260. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation 6-inch o.c. of base insulation 6-inch o.c. Membrane / WB181 _157.5 gravel, overstructural concrete deck Existing smooth-orgranule-surfaced BUR; smooth -or Min. 0.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers EverGuard TPO Fleece -Back R-261. granule -surfaced SB5 or APP modified bitumen over EnergyGuard Ultra, EnergyGuard RH, GAF 2-Part GAF 2-Part -180.0 structural concrete deck EnergyGuard RN base insulation Membrane / WB181 Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced GAF 2-Part, (Optional) Additional layer GAF 2-Part, EverGuard TPO Fleece -Back R-262. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation 4-inch o.c. of base insulation 4-inch o.c. Membrane / WB181 _200.0 gravel, overstructural concrete deck R-263. Existing smooth-orgranule-surfaced BUR orsmooth-or Min. 1-inch EnergyGuard Polyiso Insulation, LRF-M None N/A EverGuard TPO Fleece -Back 450 granule -surfaced modified bitumen EnergyGuard Ultra Membrane / WB181 Existing smooth-orgranule-surfaced BUR orsmooth- or Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece -Back R-264. granule -surfaced modified bitumen over structural EnergyGuard Ultra LRF-M None N/A Membrane / W6181 -75.0 concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO Fleece -Back R-265. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M of base insulation LRF-M Membrane / WB181 -110.0 gravel, overstructural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen orgravel-surfaced LRF-M, 6- (Optional) Additional layer LRF-M, 6- EverGuard TPO Fleece -Back R-266. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. Membrane / WB181 -157.5 gravel, overstructural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or R-267. granule surfaced SB5 modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M, 4- (Optional) Additional layer LRF-M, 4- EverGuard TPO Fleece -Back -200.0 BUR, brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Membrane / WB181 gravel, over structural concrete deck Min. 0.5-inch EnergyGuard Existing smooth- orgranule-surfaced BUR or smooth- or (Optional) 0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, EverGuard TPO Fleece -Back R-268. granule -surfaced modified bitumen over structural Insulation or min. Min. 1.5-inch EnergyGuard LRF-M EnergyGuard HD Polyiso LRF-M Membrane / WB181 75.0 concrete deck RH Insulation, EnergyGuard HD Plus Polyiso Insulation NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02819 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 145 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) (Optional when using base Existing smooth- orgranule-surfaced BUR or smooth- or (Optional when using coverboard) Min. 0.5-inch insulation) Min. 0.25-inch EverGuard TPO Fleece -Back R-269. granule -surfaced SBS or granule -surfaced APP modified EnergyGuard Polyiso Insulation, EnergyGuard LRF-M DensDeck Prime or LRF-M Membrane / WB181 -225.0 bitumen overstructural concrete deck Ultra or min. 1.5-inch EnergyGuard RH SECUROCK Gypsum -Fiber Roof Board R270 Existing smooth- orgranule-surfaced BUR or smooth -or Min. 1-inch EnergyGuard Polyiso Insulation, LRF-XF None N/A EverGuard TPO Fleece -Back 450 granule -surfaced modified bitumen EnergyGuard Ultra Membrane / WB181 Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SB5 modified bitumen or gravel -surfaced (Optional) Additional layer EverGuard TPO Fleece -Back R-271. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF of base insulation LRF-XF Membrane / WB181 _110.0 gravel, over structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or R 272 granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnerGuard Poliso Insulation gyy LRF-XF, 6- (Optional) Additional layer LRF-XF, 6- EverGuard TPO Fleece -Back _157.5 BUR, brushed/spudded and vacuumed to remove loose inch o.c. of base insulation inch o.c. Membrane / WB181 gravel, over structural concrete deck Existing smooth-orgranule-surfaced BUR; smooth -or Min. 0.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers EverGuard TPO Fleece -Back R-273. granule -surfaced SBS or APP modified bitumen over EnergyGuard Ultra or EnergyGuard RH LRF-XF base insulation LRF-XF Membrane / WB181 -180.0 structural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced LRF-XF, 4- (Optional) Additional layer LRF-XF, 4- EverGuard TPO Fleece -Back R-274. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. Membrane / WB181 -200.0 gravel, over structural concrete deck Existing smooth- orgranule-surfaced BUR; smooth -or Min.1-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece -Back R-275. granule -surfaced SBS modified bitumen or granule- EnergyGuard Ultra OB500 None OB500 Membrane / WB181 -45.0 surfaced APP modified bitumen Existing smooth- or granule -surfaced BUR; smooth- or R-276. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional) Additional layer OB500 EverGuard TPO Fleece -Back -110.0 BUR, brushed/spudded and vacuumed to remove loose of base insulation Membrane / WB181 gravel, overstructural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule -surfaced SBS modified bitumen or granule- Min. 1.5-inch EnergyGuard RA, EnergyGuard (Optional) Additional layers EverGuard TPO Fleece -Back R 277 surfaced APP modified bitumen overstructural concrete RH, EnergyGuard RN OB500 base insulation OB500 Membrane / WB181 -120.0 deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced OB500, 6- (Optional) Additional layer OB500, 6- EverGuard TPO Fleece -Back R 278 BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. Membrane / WB181 -157.5 gravel, overstructural concrete deck Existing smooth- or granule -surfaced BUR; smooth- or granule surfaced SBS modified bitumen or gravel -surfaced OB500, 4- (Optional) Additional layer OB500, 4- EverGuard TPO Fleece -Back R 279 BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. Membrane / WB181 -200.0 gravel, overstructural concrete deck NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMD ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 146 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Min. 0.5-inch EnergyGuard Existing smooth- orgranule-surfaced BUR; smooth -or (Optional) 0.5-inch EnergyGuard Polyiso RH HD Polyiso Insulation, R-280. granule -surfaced SBS modified bitumen or granule- Insulation or min. Min. 1.5-inch EnergyGuard OB500 EnergyGuard HD Polyiso 06500 EverGuard TPO Fleece -Back 97 5 surfaced APP modified bitumen over structural concrete Membrane / WB181 deck RH Insulation, EnergyGuard HD Plus Polyiso Insulation Existing smooth- or granule -surfaced BUR; smooth- or Min. 0.25-inch DensDeck granule -surfaced SB5 modified bitumen or granule- (Optional) Min. 1.5-inch EnergyGuard RA, EverGuard TPO Fleece -Back R-281. surfaced APP modified bitumen over structural concrete EnergyGuard RH, EnergyGuard RN OB500 Prime or SECUROCK OB500 Membrane / WB181 -120.0 deck Gypsum -Fiber Roof Board (Optional when using base Existing smooth-orgranule-surfaced BUR; smooth -or (Optional when using coverboard) Min. 0.5-inch insulation) Min. 0.25-inch EverGuard TPO Fleece -Back R-282. granule -surfaced SB5 or APP modified bitumen over EnergyGuard Polyiso Insulation, EnergyGuard OB500 DensDeck Prime or OBS00 Membrane / -225.0 structural concrete deck Ultra or min. 1.5-inch EnergyGuard RH SECUROCK Gypsum -Fiber Roof Board EverGuard TPO Fleece -Back Membrane in LRF Adhesive M or LRF Adhesive O: EverGuard TPO Fleece R-283. Existing smooth-orgranule-surfaced BUR or or Min. 1-inch EnergyGuard Polyiso Insulation, GAF 2-Part None N/A -Back Membrane /LRF-or LRF- -45.0 granule -surfaced modified bitumen EnergyGuard Ultra 0, 12-inch o.c. Existing smooth- or granule -surfaced BUR; smooth -or EverGuard TPO Fleece -Back R 284 granule surfaced SB5 modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional) Additional layer GAF 2-Part Membrane /LRF-M or LRF- -60.0 BUR, brushed/spudded and vacuumed to remove loose gravel, over structural concrete deck of base insulation O, 12-inch o.c. Optional additional layers Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso base insulation followed by EverGuard TPO Fleece -Back R-285. granule -surfaced SB5 modified bitumen or granule- Insulation, EnergyGuard Ultra, EnergyGuard RH, GAF 2-Part min. 0.25-inch DensDeck GAF 2-Part Membrane / LRF-M or LRF- -180.0 surfaced APP modified bitumen overstructural concrete deck EnergyGuard RN Prime or SECUROCK 0, 4-inch o.c. Gypsum -Fiber Roof Board EverGuard TPO Fleece -Back R-286. Existing smooth- orgranule-surfaced BUR or smooth -or Min. 1-inch EnergyGuard Polyiso Insulation, LRF-M None N/A Membrane / LRF-M or LRF- -45.0 granule -surfaced modified bitumen EnergyGuard Ultra O, 12-inch o.c. Existing smooth-orgranule-surfaced BUR orsmooth- or (Optional) Min. 1-inch EnergyGuard RA, Min. 1.5-inch EnergyGuard EverGuard TPO Fleece -Back R-287. LRF-M LRF-M Membrane / LRF-M or LRF- -45.0 granule -surfaced modified bitumen EnergyGuard RH, EnergyGuard RN RA, EnergyGuard RN O, 12-inch o.c. Existing smooth-orgranule-surfaced BUR orsmooth-or (Optional) Min. 1-inch EnergyGuard RA, Min. 1.5-inch EnergyGuard EverGuard TPO Fleece -Back R-288. granule -surfaced modified bitumen EnergyGuard RH, EnergyGuard RN LRF-M RH LRF-M Membrane /LRF-O, 12-inch O.C. -45.0 Existing smooth-orgranule-surfaced BUR orsmooth- or Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece -Back R-289. granule -surfaced modified bitumen over struct. concrete LRF-M None N/A Membrane / LRF-M or LRF- -60.0 deck EnerGuard Ultra gy O, 12-inch o.c. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 147 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back R-290. granule surfaced SB5 modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional) Additional layer LRF-M Membrane / LRF-M or LRF- -60.0 BUR, brushed/spudded and vacuumed to remove loose gravel, overstructural concrete deck of base insulation 0, 12-inch o.c. EverGuard TPO Fleece -Back R-291. Existing smooth-orgranule-surfaced BUR orsmooth- or (Optional) Min. 1-inch EnergyGuard RA or LRF-M Min. 1.75-inch ACFoam LRF-M Membrane / LRF-M, 12-inch -37.5 granule -surfaced modified bitumen ACFoam II Composite/GB O.C. (Optional) Min. 0.5-inch EnergyGuard Polyiso R-292. Existing smooth-orgranule-surfaced BUR or smooth -or Insulation, EnergyGuard Ultra or min. 1-inch LRF-M Min. 0.25-inch DensDeck LRF-M EverGuard TPO Fleece -Back Membrane /LRF-M, 12-inch -37.5 granule -surfaced modified bitumen EnergyGuard RA, EnergyGuard RH, Prime EnergyGuard RN O.C. (Optional) Min. 0.5-inch EnergyGuard Polyiso Existing smooth-orgranule-surfaced BUR orsmooth-or Insulation, EnergyGuard Ultra or min. 1-inch Min. 0.25-inch DensDeck EverGuard TPO Fleece -Back R-293. LRF-M LRF-M Membrane/LRF-0, 12-inch -45.0 granule -surfaced modified bitumen EnergyGuard RA, EnergyGuard RH, Prime EnergyGuard RN O.C. (Optional) Min. 0.5-inch EnergyGuard Polyiso R-294. Existing smooth-orgranule-surfaced BUR orsmooth-or Insulation, EnergyGuard Ultra or min. 1-inch LRF-M Min. 0.25-inch SECUROCK LRF-M EverGuard TPO Fleece -Back Membrane /LRF-M or LRF- -45.0 granule -surfaced modified bitumen EnergyGuard RA, EnergyGuard RH, Gypsum -Fiber Roof Board EnergyGuard RN 0, 12-inch o.c. Min. 0.25-inch Temple EverGuard TPO Fleece -Back R-295. Existing smooth-orgranule-surfaced BUR or smooth -or (Optional) Min. 1-inch EnergyGuard RA, LRF-M Green Glass Primed Roof LRF-M Membrane / LRF-M or LRF- -37.5 granule -surfaced modified bitumen EnergyGuard RH, EnergyGuard RN Board 0, 12-inch o.c. Optional additional layers Existing smooth-orgranule-surfaced BUR or smooth- or (Optional) Min. 0.5-inch EnergyGuard Polyiso base insulation followed by EverGuard TPO Fleece -Back R-296. granule -surfaced modified bitumen over structural Insulation, EnergyGuard Ultra, EnergyGuard RH, LRF-M min. 0.25-inch DensDeck LRF-M Membrane / LRF-M or LRF- -180.0 concrete deck EnergyGuard RN Prime or SECUROCK 0, 4-inch o.c. Gypsum -Fiber Roof Board EverGuard TPO Fleece R-297. Existing smooth-orgranule-surfaced BUR orsmooth- or Min. 1-inch EnergyGuard Polyiso Insulation, LRF-XF None N/A -Back Membrane /LRF-or LRF- -45.0 granule -surfaced modified bitumen EnergyGuard Ultra 0, 12-inch o.c. Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back R-298. granule surfaced SB5 modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF (Optional) Additional layer LRF-XF Membrane / LRF-M or LRF- -60.0 BUR, brushed/spudded and vacuumed to remove loose gravel, overstructural concrete deck of base insulation 0, 12-inch o.c. Optional additional layers Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso base insulation followed by EverGuard TPO Fleece -Back R 299 granule -surfaced SB5 modified bitumen or granule- Insulation, EnergyGuard Ultra or EnergyGuard LRF-XF min. 0.25-inch DensDeck LRF-XF Membrane / LRF-M or LRF- -180.0 surfaced APP modified bitumen over structural concrete deck RH Prime or SECUROCK 0, 4-inch o.c. Gypsum -Fiber Roof Board NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 148 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth- orgranule-surfaced BUR; smooth -or Min.1-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece -Back R-300. granule -surfaced SB5 modified bitumen or granule- OB500 None N/A Membrane / LRF-M or LRF- -45.0 surfaced APP modified bitumen nergyuarra EnergyGuard Ultra 0, 12-inch o.c. Existing smooth-orgranule-surfaced BUR; smooth -or . a 1 a (Optional) Min1-inch EnergyGuard RA, Min. 1.5-inch EnergyGuard rg rgyGuard EverGuard TPO Fleece -Back R-301. granule -surfaced SBS modified bitumen or granule- OB500 OB500 Membrane / LRF-M or LRF- -45.0 surfaced APP modified bitumen EnergyGuard EnergyGuard gy RAEnergyGuard , O, 12-inch o.c. Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Min. 1-inch EnergyGuard RA, Min. 1.5-inch EnergyGuard EverGuard TPO Fleece -Back R-302. granule -surfaced SBS modified bitumen or granule- 06500 OB500 Membrane / LRF-O, 12-inch -45.0 surfaced APP modified bitumen EnergyGuard RHEnergyGuard RN , RH o.c. Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back R-303. granule -surfaced SBS modified bitumen or granule- Min. 0.5-inch EnergyGuard Polyiso Insulation, OB500 None N/A Membrane / LRF-M or LRF- -60.0 surfaced APP modified bitumen overstructural concrete EnergyGuard Ultra deck O, 12-inch o.[. Existing smooth- or granule -surfaced BUR; smooth -or EverGuard TPO Fleece -Back R-304. granule surfaced SBS modified bitumen or gravel -surfaced Min. 1.5-inch EnergyGuard Polyiso Insulation OB500 (Optional) Additional layer OB500 Membrane / LRF-M or LRF- -60.0 BUR, brushed/spudded and vacuumed to remove loose gravel, over structural concrete deck of base insulation O, 12-inch o.c. Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Min. 1-inch EnergyGuard RA or Min. 1.75-inch ACFoam EverGuard TPO Fleece -Back R-305. granule -surfaced SBS modified bitumen or granule- OB500 OB500 Membrane / LRF-M, 12-inch -37.5 surfaced APP modified bitumen ACFoam 11 Composite/GB O.C. (Optional) Min. 0.5-inch EnergyGuard Polyiso Existing smooth- orgranule-surfaced BUR; smooth- or Insulation, EnergyGuard Ultra or min. 1-inch Min. 0.25-inch DensDeck EverGuard TPO Fleece -Back R-306. granule -surfaced SBS modified bitumen or granule- OB500 OB500 Membrane /LRF-M, 12-inch -37.5 surfaced APP modified bitumen EnergyGuard RAEnergyGuard RH , , Prime O.C. EnergyGuard RN (Optional) Min. 0.5-inch EnergyGuard Polyiso Existing smooth- or granule -surfaced BUR; smooth- or Insulation, EnergyGuard Ultra orR min. 1-inch Min. 0.25-inch DensDeck EverGuard TPO Fleece -Back R-307. granule -surfaced SBS modified bitumen or granule- OB500 OB500 Membrane / LRF-0, 12-inch -45.0 surfaced APP modified bitumen EnergyGuard RA, EnergyGuard RH, Prime O.C. EnergyGuard RN (Optional) Min. 0.5-inch EnergyGuard Polyisoaced Existing smooth- orgranule-surfaced BUR; smooth- or Insulation, EnergyGuard Ultra or min. 1-inch Min. 0.25-inch SECUROCK EverGuard TPO Fleece -Back R-308. granule -surfaced SBS modified bitumen or granule- OB500 OB500 Membrane /LRF-M or LRF- -45.0 surfaced APP modified bitumen EnergyGuard RAEnergyGuard RH , , Gypsum -Fiber Roof Board O, 12-Inch o.c. EnergyGuard RN Existing smooth-orgranule-surtaced BUR; smooth -or (Optional) Min. 1-inch EnergyGuard RA, Min. 0.25-inch Temple EverGuard TPO Fleece -Back R-309. granule -surfaced SBS modified bitumen or granule- OB500 Green Glass Primed Roof OB500 Membrane / LRF-M or LRF- -37.5 surfaced APP modified bitumen EnergyGuard RHEnergyGuard RN gy, gy Board 0, 12-inch o.c. Optional additional layers Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso base insulation followed by EverGuard TPO Fleece -Back R-310. granule -surfaced SBS modified bitumen or granule- Insulation, EnergyGuard Ultra, EnergyGuard RH, OB500 min. 0.25-inch DensDeck OB500 Membrane / LRF-M or LRF- -180.0 surfaced APP modified bitumen overstructural concrete deck EnergyGuard RN Prime or SECUROCK 0, 4-inch o.c. Gypsum -Fiber Roof Board NEW ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NENIO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 149 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer y System Substrate (Notes 1 & 12) Attach Attach Roof Cover (Note 15) ;p� Type Type (Notes 6,7,8) (Notes 6,7,8) EverGuard TPO Fleece -Back Membrane in Spatter Applications: EverGuard TPO Fleece -Back R-311. Existing smooth -or granule -surfaced BUR or smooth -or Min. 1-inch EnergyGuard Polyiso Insulation, GAF 2-Part None N/A Membrane/GAF 2-Part granule -surfaced modified bitumen EnergyGuard Ultra (spatter), LRF-XF (spatter) or -45.0 OB500 (spatter) Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back R-312. granule surfaced SBS modified bitumen or gravel -surfaced Min1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part (Optional) Additional layer GAF 2-Part Membrane / GAF 2-Part -110.0 BUR, brushed/spudded and vacuumed to remove loose . of base insulation (spatter), LRF-XF (spatter) or gravel, overstructural concrete deck OB500 (spatter) Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back granule surfaced SBS modified bitumen or gravel -surfaced GAF 2-Part, (Optional) Additional layer GAF 2-Part, Membrane / GAF 2-Part R-313. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation 6-inch o.c. of base insulation 6-inch o.c. (spatter), LRF-XF (spatter) or _157.5 gravel, over structural concrete deck OB500 (spatter) EverGuard Fleece -Back Existing smooth-orgranule-surfaced BUR; smooth -or Min. 0.5-inch EnergyGuard Polyiso Insulation, (Optional) Additional layers G Membrane /GAF 2-Part / R-314. granule -surfaced or APP modified bitumen over EnergyGuard Ultra, EnergyGuard RA, GAF 2-Part base insulation GAF 2-Part (spatter), LRF-XF (spatter) or -180.0 structural concretee deck EnergyGuard RH, EnergyGuard RN OB500 (spatter) Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back granule surfaced SBS modified bitumen or gravel -surfaced GAF 2-Part, (Optional) Additional layer GAF 2-Part, Membrane / GAF 2-Part R-315. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation 4-inch O.C. of base insulation 4-inch o.c. (spatter), LRF-XF (spatter) or _200.0 gravel, overstructural concrete deck OB500 (spatter) Optional additional layers EverGuard TPO Fleece -Back Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso base insulation followed by Membrane / GAF 2-Part /G R-316. granule -surfaced SBS or APP modified bitumen over Insulation, EnergyGuard Ultra, EnergyGuard RA, GAF 2-Part min. 0.25-inch DensDeck GAF 2-Part -180.0 structural concrete deck EnergyGuard RH, EnergyGuard RN Prime or SECUROCK (spatter), F (spatter) or OB500 (spatter) Gypsum -Fiber Roof Board EverGuard TPO Fleece -Back R-317. Existing smooth-orgranule-surfaced BUR orsmooth-or Min. 1-inch EnergyGuard Polyiso Insulation, LRF-M None N/A Membrane/GAF 2-Part 45.0 granule -surfaced modified bitumen EnergyGuard Ultra (spatter), LRF-XF (spatter) or OB500 (spatter) Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer Membrane / GAF 2-Part R-318. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-M of base insulation LRF-M (spatter), LRF-XF (spatter) or -110.0 gravel, overstructural concrete deck OB500 (spatter) Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back granule surfaced SBS modified bitumen or gravel -surfaced LRF-M, 6- (Optional) Additional layer LRF-M, 6- Membrane / GAF 2-Part R-319. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. (spatter), LRF-XF (spatter) or -157.5 gravel, over structural concrete deck I I I I I OB500 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FLS293-1146 Certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 150 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back granule surfaced SBS modified bitumen or gravel -surfaced LRF-M, 4- (Optional) Additional layer LRF-M, 4- Membrane / GAF 2-Part R-320. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. (spatter), LRF-XF (spatter) or -200.0 gravel, over structural concrete deck OB500 (spatter) Optional additional layers Existing smooth-orgranule-surfaced BUR orsmooth- or (Optional) Min. 0.5-inch EnergyGuard Polyiso base insulation followed by EverGuard TPO Fleece -Back R-321. granule -surfaced modified bitumen over structural Insulation, EnergyGuard Ultra, EnergyGuard RH, LRF-M min. 0.25-inch DensDeck LRF-M Membrane / GAF 2-Part -180.0 concrete deck EnergyGuard RN Prime or SECUROCK (spatter), LRF-XF (spatter) or OB500 (spatter) Gypsum -Fiber Roof Board EverGuard TPO Fleece -Back R-322. Existing smooth-orgranule-surfaced BUR orsmooth-or Min. 1-inch EnergyGuard Polyiso Insulation, LRF-XF None N/A Membrane/GAF 2-Part 45.0 granule -surfaced modified bitumen EnergyGuard Ultra (spatter), LRF-XF (spatter) or OB500 (spatter) Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer Membrane / GAF 2-Part R-323. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF of base insulation LRF-XF (spatter), LRF-XF (spatter) or -110.0 gravel, overstructural concrete deck OB500 (spatter) Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back granule surfaced SBS modified bitumen orgravel-surfaced LRF-XF, 6- (Optional) Additional layer LRF-XF, 6- Membrane / GAF 2-Part R-324. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. (spatter), LRF-XF (spatter) or -157.5 gravel, over structural concrete deck OB500 (spatter) Existing smooth-orgranule-surfaced BUR; smooth -or Min. 0.5-inch EnergyGuard Polyiso Insulation, EverGuard TPO Fleece -Back (Optional) Additional layers Membrane / GAF 2-Part R-325. granule -surfaced SBS or APP modified bitumen over EnergyGuard Ultra, EnergyGuard RA or LRF-XF base insulation LRF-XF (spatter), LRF-XF (spatter) or -180.0 structural concrete deck EnergyGuard RH OB500 (spatter) Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back granule surfaced SBS modified bitumen or gravel -surfaced LRF-XF, 4- (Optional) Additional layer LRF-XF, 4- Membrane / GAF 2-Part R-326. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. (spatter), LRF-XF (spatter) or -200.0 gravel, over structural concrete deck OB500 (spatter) Optional additional layers Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso base insulation followed by EverGuard TPO Fleece -Back R-327. granule -surfaced SBS or APP modified bitumen over Insulation, EnergyGuard Ultra, EnergyGuard RA LRF-XF min. 0.25-inch DensDeck LRF-XF Membrane / GAF 2-Part (spatter), LRF-XF (spatter) or -180.0 structural concrete deck or EnergyGuard RH Prime or SECUROCK Gypsum -Fiber Roof Board OB500 (spatter) EverGuard TPO Fleece -Back Existing smooth-orgranule-surfaced BUR; smooth -or Min.1-inch EnergyGuard Polyiso Insulation, Membrane/GAF 2-Part R-328. granule -surfaced SBS modified bitumen or granule- EnergyGuard Ultra 0B500 None N/A (spatter), LRF-XF (spatter) or -45.0 surfaced APP modified bitumen OB500 (spatter) NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization H32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 151 of 156 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Sy Substrate (Notes 1 & 12) Roof Cover (Note 15) Psfl Attach Attach oem No. Type Type (Notes 6,7,8) (Notes 6,7,8) Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back granule surfaced SBS modified bitumen or gravel -surfaced (Optional) Additional layer Membrane / GAF 2-Part R-329. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation OB500 of base insulation OB500 (spatter), LRF-XF (spatter) or -110.0 gravel, overstructural concrete deck OB500 (spatter) Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back granule surfaced SBS modified bitumen or gravel -surfaced 0B500, 6- (Optional) Additional layer OB500, 6- Membrane / GAF 2-Part R-330. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. (spatter), LRF-XF (spatter) or -157.5 gravel, over structural concrete deck OB500 (spatter) Existing smooth- or granule -surfaced BUR; smooth- or EverGuard TPO Fleece -Back granule surfaced SBS modified bitumen or gravel -surfaced OB500, 4- (Optional) Additional layer OB500, 4- Membrane / GAF 2-Part R-331. BUR, brushed/spudded and vacuumed to remove loose Min. 1.5-inch EnergyGuard Polyiso Insulation inch o.c. of base insulation inch o.c. (spatter), LRF-XF (spatter) or -200.0 gravel, over structural concrete deck OB500 (spatter) Optional additional layers Existing smooth-orgranule-surfaced BUR; smooth -or (Optional) Min. 0.5-inch EnergyGuard Polyiso base insulation followed by EverGuard TPO Fleece -Back R-332. granule -surfaced SBS modified bitumen or granule- Insulation, EnergyGuard Ultra, EnergyGuard RH, 0B500 min. 0.25-inch DensDeck OB500 Membrane /GAF 2-Part -180.0 surfaced APP modified bitumen overstructural concrete (spatter), LRF-XF (spatter) or deck EnergyGuard RN Prime orSECUROCK OB500 (spatter) Gypsum -Fiber Roof Board TABLE 713: WOOD OR SYSTEM TYPE C-2: PLATE -BONDED•.. (All areas System where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre -drilled into the Substrate Attachment panel prior to driving the Purlin Fastener into the purlin.) MDP No. Insulation Layer (Note 1) Fasteners (Note 11) Spacing Roof Cover (Note 158) (psf) Existing standing seam or lap seam metal One or more layers, any Drill-Tec Purlin Fasteners or Drill-Tec Hex - Hex - EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-333. roof covers having min. 16 gauge (0.0598 combination, Head Purlin Fasteners and Drill-Tec 18-inch o.c. XHD Plates with RhinoBond Portable Bonding Tool, per -30.0 inch), 50 ksi or min. gauge (0.105 in.), 36 preliminarily fastened h inTPO XHD Plates are fastened along purlins manufacturer's published instructions. ksi steel purlins spaced max. 60-inch o.c. through to purlins t to Existing standing seam or lap seam metal One or more layers, any Drill-Tec Purlin Fasteners and Drilll Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-334. roof covers having min. 16 gauge (0.0598 combination, min. 2- XHD Tread Safe Plates are 18-inch o.c. XHD Tread Safe Plates with RhinoBond Portable inch), 50 ksi or min. 12 gauge 0.105 in.), 36 ) 8 g ( ) inch total thickness, along-30.0 purlins Bonding Tool, per manufacturers published ksi steel purlins spaced max. 60-inch o.c. preliminarily fastened fastened through to purlins fastened t rou instructions. Existing standing seam or lap seam metal One or more layers, any Drill-Tec #14 (min. 1.05-inch embedment) 12-inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-335. roof covers having nominal No. 2 wood combinationloose laid , and Drill-Tec RhinoBond TPO XHD Plates along wood XHD Plates with RhinoBond Portable Bonding Tool, per -30.0 trusses spaced max. 96-inch o.c. are fastened through to wood supports supports manufacturer's published instructions. One or more layers, any Drill-Tec #14 (min. 1.05-inch embedment) EverGuard TPO bonded to Drill-Tec RhinoBond TPO Existing standing seam or lap seam metal combination, min. 2- and Drill-Tec RhinoBond TPO XHD Tread 12-inch o.c. XHD Tread Safe Plates with RhinoBond Portable R-336. roof covers having nominal No. 2 wood inch total thickness, Safe Plates are fastened through to wood along wood Bonding Tool, per manufacturers published -30.0 trusses spaced max. 96-inch o.c. loose laid supports supports instructions. 11 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for F1.5293-1146 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 152 of 156 NNEMO I etc. TABLE 713: WOOD OR PLATE-BONDEDSYSTEM TYPE C-2: ROOF COVER (All areas System where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre -drilled into the Substrate Attachment panel priorto drivingthe Purlin Fastenerintothe purlin.) MDP No. Insulation Layer (Note 1) Fasteners (Note li) Spacing Roof Cover (Note 158) (psf) Existing standing seam or lap seam metal One or more layers, any Drill-Tec Purlin Fasteners or Drill-Tec Hex EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-337. roof covers having min. 14 gauge (0.0747 combination, Head Purlin Fasteners and Drill-Tec 18-inch o.c. XHD Plates with RhinoBond Portable Bonding Tool, per -37.5 inch), 50 ksi or min. 12 gauge (0.105 in.), 36 preliminarily fastened RhinoBond TPO XHD Plates are fastened along purlins manufacturer's published instructions. ksi steel purlins spaced max. 60-inch o.c. through to purlins Existing standing seam or lap seam metal One or more layers, any Drill-Tec Purlin Fasteners and Drilll Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-338. roof covers having min. 14 gauge (0.0747 combination, min. 2- XHD Tread Safe Plates are 18-inch o.c. XHD Tread Safe Plates with RhinoBond Portable inch), 50 ksi or min. 12 gauge 0.105 in.), 36 ) 8 8 ( ) inch total thickness, fastened fastened through to purlins t rou along-37.5 purlins Bonding Tool, per manufacturer's published ksi steel purlins spaced max. 60-inch o.c. preliminarily fastened instructions. Existing standing seam or lap seam metal One or more layers, any Drill-Tec #14 (min. 1.05-inch embedment) 24-inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-339. roof covers having nominal No. 2 wood combinationloose laid , and Drill-Tec RhinoBond TPO XHD Plates along wood XHD Plates with RhinoBond Portable Bonding Tool, per -37.5 trusses spaced max. 48-inch o.c. are fastened through to wood supports supports manufacturer's published instructions. Existing standing seam or lap seam metal One or more layers, any Drill-Tec #14 (min. 1.05-inch embedment) 24-inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-340. roof covers having nominal No. 2 wood combination, min. 2- and Drill-Tec RhinoBond TPO XHD Tread along wood XHD Tread Safe Plates with RhinoBond Portable -37.5 trusses spaced max. 48-inch o.c. inch total thickness, Safe Plates are fastened through to wood supports Bonding Tool, per manufacturers published loose laid supports instructions. Existing standing seam or lap seam metal One or more layers, any Drill-Tec Purlin Fasteners or Drill-Tec Hex - EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-341. roof covers having min. 16 gauge (0.0598 combination, Head Purlin Fasteners and Drill-Tec 12-inch o.c. XHD Plates with RhinoBond Portable Bonding Tool, per -45.0 inch), 50 ksi or min. gauge (0.105 in.), 36 preliminarily fastened RhinoBond TPO XHD Plates are fastened along purlins manufacturer's published instructions. ksi steel purlins spaced max. 60-inch o.c. through through ugh tto purlins Existing standing seam or lap seam metal metal One or more layers, any Drill-Tec Purlin Fasteners and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-342. roof covers having min. 16 gauge (0.0598 combination, min. XHD Tread Safe Plates are 12-inch o.c. XHD Tread Safe Plates with RhinoBond Portable -45.0 inch), 50 ksi or min. 12 gauge (0.105 in.), 36 inch total thickness, along purlins Bonding Tool, per manufacturer's published ksi steel purlins spaced max. 60-inch o.c. preliminarily fastened t rou fastened through to purlins fastened instructions. Existing standing seam or lap seam metal Drill-Tec #14 (min. 1-inch embedment) and 36-inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-343. roof covers having nominal No. 2 wood munch One or more layers, any Drill-Tec RhinoBond TPO XHD Plates or along wood XHD Plates or Drill-Tec RhinoBond TPO XHD Tread Safe -52.5 trusses spaced max. o combination Drill-Tec RhinoBond TPO XHD Tread Safe supports, 24- Plates with RhinoBond Portable Bonding Tool, per Plates through to wood supports inch o.c. manufacturer's published instructions. Existing standing seam or lap seam metal One or more layers, any Drill-Tec Purlin Fasteners or Drill-Tec Hex EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-344. roof covers having min. 16 gauge (0.0598 combination, Head Purlin Fasteners and Drill-Tec 6-inch o.c. XHD Plates with RhinoBond Portable Bonding Tool, per -67.5 inch), 50 ksi or min. gauge (0.105 in.), 36 RhinoBond TPO XHD Plates are fastened along purlins ksi steel purlins spaced max. 72-inch o.c. preliminarily fastened through through ugh tto purlins manufacturer's published instructions. Existing standing seam or lap seam metal One or more layers, any Drill-Tec Purlin Fasteners and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-345. roof covers having min. 16 gauge (0.0598 combination, min. 2- RhinoBond TPO XHD Tread Safe Plates are 6-inch o.c. XHD Tread Safe Plates with RhinoBond Portable -67.5 inch), 50 ksi or min. 12 gauge (0.105 in.), 36 inch total thickness, fastened through to purlins along purlins Bonding Tool, per manufacturers published ksi steel purlins spaced max. 72-inch o.c. instructions. Existing standing seam or lap seam metal Drill-Tec #14 (min. 1-inch embedment) and 24-inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-346. roof covers having nominal No. 2 wood One or more layers, any Drill-Tec RhinoBond TPO XHD Plates or along wood XHD Plates or Drill-Tec RhinoBond TPO XHD Tread Safe 75 0 trusses spaced max. 24-inch o.c. combination Drill-Tec RhinoBond TPO XHD Tread Safe supports, 24- Plates with RhinoBond Portable Bonding Tool, per Plates through to wood supports inch o.c. manufacturer's published instructions. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 153 of 156 NNEMO I etc. TABLE 713: WOOD OR PLATE-BONDEDSYSTEM TYPE C-2: ROOF COVER (All areas System where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre -drilled into the Substrate Attachment panel priorto drivingthe Purlin Fastener intothe purlin.) MDP No. Insulation Layer (Note 1) Fasteners (Note li) Spacing Roof Cover (Note 158) (psf) Existing standing seam or lap seam metal Drill-Tec #14 (min. 1-inch embedment) and 18-inch o.c. EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-347. roof covers having nominal No. 2 wood One or more layers, any Drill-Tec RhinoBond TPO XHD Plates or along wood XHD Plates or Drill-Tec RhinoBond TPO XHD Tread Safe 82 5 trusses spaced max. 24-inch o.c. combination Drill-Tec RhinoBond TPO XHD Tread Safe supports, 24- Plates with RhinoBond Portable Bonding Tool, per Plates through to wood supports inch o.c. manufacturer's published instructions. Existing standing seam or lap seam metal One or more layers, any Drill-Tec Purlin Fasteners or Drill-Tec Hex EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-348. roof covers having min. 14 gauge (0.0747 combination, Head Purlin Fasteners and Drill-Tec 6-inch o.c. XHD Plates with RhinoBond Portable Bonding Tool, per -97.5 inch), 50 ksi or min. 12 gauge (0.105 in.), 36 preliminarily fastened RhinoBond TPO XHD Plates are fastened along purlins manufacturer's published instructions. ksi steel purlins spaced max. 72-inch o.c. through to purlins Existing standing seam or lap seam metal One or more layers, any Drill-Tec Purlin Fasteners and Drill-Tec EverGuard TPO bonded to Drill-Tec RhinoBond TPO R-349. roof covers having min. 14 gauge (0.0747 combination, min. 2- RhinoBond TPO XHD Tread Safe Plates are inch Lacs XHD Tread Safe Plates with Portable 97 5 inch), 50 ksi or min. 12 gauge (0.105 in.), 36 inch total thickness, fastened through to purlins al along purlins manufacturer's ubl Bonding Tool, per manufacturer's published ksi steel purlins spaced max. 72-inch o.c. preliminarily fastened instructions. SYSTEM TYPE INSULATED,TABLE 7c: STEEL -RECOVER D-1: MECHANICALLY ATTACHED ROOF (All areas where the existing metal panels do not lay flush on the underlying System Deck (Note 1) Insulation purlin shall have a r .25-inch diameter Separator Sheet (Optional) pilot hole pre -drilled into the panel prior to driving the Purlin Fastener into the purlin.) Roof Cover (Note 15A) MDP Membrane Fasteners (Note 11) Attachment No. (Psf) Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation Drill-Tec Purlin Fasteners and Drill-Tec 12-inch o.c. within min. 6- covers having min. 16 gauge (0.0598 inch), 50 layers, any Layer (3 oz/ydz) or EverGuard EverGuard Eyehook AccuSeam Plates or Eyehook inch wide laps spaced max. R-350. ksi or min. 12 gauge (0.105 in.), 36 ksi steel combination, Polymat Cushioning Layer (6 TPO Reel -Fast Plates or Drill-Tec #12Perlin 84-inch Lacs to engage steel -30.0 purlins spaced max. 84-inch o.c. prelim. attached oz/ydz) Fasteners with Drill-Tec 2.4" Barbed Seam Barbed purlins Laps sealed with 1.5- Plate or Drill-Tec 2.4" Scoop Seam Plate inch heat weld. Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation Drill-Tec Purlin Fasteners and Drill-Tec 2 12-inch o.c. within min. 6- covers having min. 14 gauge (0.0747 inch), 50 layers, any Layer (3 oz/ydz) or EverGuard EverGuard in. Double Barbed XHD Plates or Drill-Tec inch wide laps spaced max. R-351. ksi or min. 12 gauge (0.105 in.), 36 ksi steel combination, Polymat Cushioning Layer (6 TPO #12Perlin Fasteners with Drill-Tec 84-inch Lacs to engage steel -30.0 purlins spaced max. 84-inch o.c. prelim. attached oz/ydz) Barbed Seam Plate or Drill-Tec 2.4" Scoop Bar c S purlins Laps sealed with 1.5- Seam Plate inch heat weld. Drill-Tec Hex Head Purlin Fasteners and Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation Drill-Tec 2 in. Double Barbed XHD Plates, 12-inch o.c. in rows spaced covers having min. 16 gauge (0.0598 inch), 50 layers, any Layer (3 oz/ydz) or EverGuard EverGuard Drill-Tec 2-3/8 in. Barbed XHD Plates, max. 114-inch Lacs to engage R-352. ksi or min. 12 gauge (0.105 in.), 36 ksi steel combination, Polymat Cushioning Layer (6 TPO Drill-Tec Eyehook AccuSeam Plates or steel purlin. An 8-inch wide -30.0 purlins spaced max. 114-inch o.c. prelim. attached oz/ydz) Drill-Tec #12 Purlin Fasteners with Drill- cover strip is heat welded Tec 2.4" Barbed Seam Plate or Drill-Tec over the stress plates. 2.4" Scoop Seam Plate NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 154 of 156 NNEMO I etc. SYSTEIVITYPED-1: TABLE 7c: STEEL -RECOVER INSULATED, MECHANICALLY ATTACHED ROOF (All areas where the existing metal panels do not lay System flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre -drilled into the panel prior to driving the Purlin Fastener intothe purlin.) Roof Cover (Note 1SA) MDP Deck (Note 1) No. Insulation Separator Sheet (Optional) (psf) Membrane Fasteners (Note 11) Attachment Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation Drill-Tec Purlin Fasteners and Drill-Tec 2- 12-inch o.c. within min. 6- min. 14 gauge (0.0747 inch), 50 layers, any 2) or Layer (3 oz/ydz) or EverGuard EverGuard 3/8 in. Barbed XHD Plates or Drill-Tec #12 inch wide laps spaced max. R-353. ksi or min. 12 gauge (0.105 in.), 36 ksi steel combination, Polymat Cushioning Layer (6 TPO Purlin Fasteners with .4Tec" Barbed 84-inch Lacs to engage steel -37.5 purlins spaced max. 84-inch o.c. prelim. attached oz/ydz) Scoop Seam Plate or Drill-Tec 22.4Seam purlin. Laps sealed with 1.5- Plate inch heat weld. Drill-Tec Hex Head Purlin Fasteners and Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation Drill-Tec 2 in. Double Barbed XHD Plates, 6-inch o.c. in rows spaced covers having min. 16 gauge (0.0598 inch), 50 layers, any Layer (3 oz/ydz) or EverGuard EverGuard Drill-Tec 2-3/8 in. Barbed XHD Plates, max. 120-inch Lacs to engage R-354. ksi or min. 12 gauge (0.105 in.), 36 ksi steel combination, Polymat Cushioning Layer (6 TPO Drill-Tec Eyehook AccuSeam Plates or steel purlin. An 8-inch wide -45.0 purlins spaced max. 120-inch o.c. prelim. attached oz/ydz) Drill-Tec #12 Purlin Fasteners with Drill- cover strip is heat welded Tec 2.4" Barbed Seam Plate or Drill-Tec over the stress plates. 2.4" Scoop Seam Plate Drill-Tec Purlin Fasteners and Drill-Tec 2 Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation in. Double Barbed XHD Plates, Drill-Tec 2- 6-inch o.c. within min. 6-inch covers having min. 16 gauge (0.0598 inch), 50 layers, any Layer (3 oz/ydz) or EverGuard EverGuard 3/8 in. Barbed XHD Plates, Drill-Tec wide laps spaced max. 84- R-355. ksi or min. 12 gauge (0.105 in.), 36 ksi steel combination, Polymat Cushioning Layer (6 TPO Eyehook AccuSeam Plates or Eyehook inch o.c. to engage steel -52.5 purlins spaced max. 84-inch o.c. prelim. attached oz/ydz) Reel -Fast Plates or Drill-Tec #12 Purlin purlin. Laps sealed with 1.5- Fasteners with Drill-Tec 2.4" Barbed Seam inch heat weld. Plate or Drill-Tec 2.4" Scoop Seam Plate Drill-Tec Hex Head Purlin Fasteners and Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation Drill-Tec 2 in. Double Barbed XHD Plates, 6-inch o.c. in rows spaced covers having min. 16 au a 0.0598 inch), 50 g gauge ( ) layers, an y y y ( y z) Layer 3 oz/ d or EverGuard EverGuard Drill-Tec 2-3/8 in. Barbed XHD Plates, max. 114-inch o.c. to engage R-356. ksi or min. 12 gauge (0.105 in.), 36 ksi steel combination, Polymat Cushioning Layer (6 TPO Drill-Tec Eyehook AccuSeam Plates or steel purlin. An 8-inch wide -52.5 purlins spaced max. 114-inch o.c. prelim. attached oz/ydz) Drill-Tec #12 Purlin Fasteners with Drill- cover strip is heat welded Tec 2.4" Barbed Seam Plate or Drill-Tec over the stress plates. 2.4" Scoop Seam Plate Existing standing seam or lap seam metal roof One or more EverGuard Polymat Separation 6-inch o.c. within min. 6-inch covers having min. 14 gauge (0.0747 inch), 50 layers, any Layer (3 oz/ydz) or EverGuard EverGuard Drill-Tec Purlin Fasteners and Drill-Tec 2- wide laps spaced max. 84- R-357. ksi or min. 12 gauge (0.105 in.), 36 ksi steel combination, Polymat Cushioning Layer (6 TPO 3/4 in. Barbed SXHD Plates inch o.c. to engage steel -60.0 purlins spaced max. 84-inch Lacs prelim. attached oz/ydz) purlin. Laps sealed with 1.5- inch heat weld. NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-R46 Certificate of Authorization #32455 7'h Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 155 of 156 NNEMO I etc. TABLE 7D: RECOVER APPLICATIONS System No. SYSTEM TYPE F: Substrate (Notes 1 & 12) .BONDED ROOF COVER Roof Cover (Note 15) MDP (psf) R-358. Existing asphaltic granule surfaced roof cover over wood, CWF or gypsum deck EverGuard TPO Fleece -Back Membrane / LRF-M or LRF-O, 12-inch o.c. -45.0 R-359. Existing asphaltic granule surfaced roof cover over steel deck EverGuard TPO Fleece -Back Membrane / LRF-M or LRF-O, 12-inch o.c. -60.0 R-360. Existing smooth or granule surfaced SBS modified bitumen or existing smooth or granule EverGuard TPO Fleece -Back Membrane /LRF-M or LRF-0, 4-inch o.c. -60.0 surfaced APP modified bitumen over steel deck R-361. Existing asphaltic granule surfaced cap sheet EverGuard TPO Fleece -Back Membrane / LRF-M, 6-inch o.c. -67.5 R-362. Existing granule surfaced BUR or granule surfaced SBS or APP modified bitumen over steel EverGuard TPO Fleece -Back Membrane /LRF-M, 4-inch o.c. -105.0 deck R-363. Existing granule surfaced BUR or granule surfaced SBS or APP modified bitumen over steel EverGuard TPO Fleece -Back Membrane / LRF-0, 4-inch o.c. -120.0 deck R-364. Existing smooth or granule surfaced SBS modified bitumen or existing smooth or granule EverGuard TPO Fleece -Back Membrane /LRF-M or LRF-O, 4-inch o.c. -337.5 surfaced APP modified bitumen over structural concrete deck R-365. Existing asphaltic granule surfaced roof cover over structural concrete deck EverGuard TPO Fleece -Back Membrane / LRF-O, 4-inch o.c. (for full coverage) -415.0 R-366. Existing asphaltic granule surfaced roof cover over structural concrete deck EverGuard TPO Fleece -Back Membrane / LRF-M, 4-inch o.c. (for full coverage) -492.5 R-367. Existing asphaltic granule surfaced roof cover over wood, CWF or gypsum deck EverGuard TPO Fleece -Back Membrane / GAF 2-Part (spatter), LRF-XF (spatter) or OB500 -45.0 (spatter) R-368. Existing smooth surfaced SBS modified bitumen over steel deck EverGuard TPO Fleece -Back Membrane / GAF 2-Part (spatter), LRF-XF (spatter) or OB500 -60.0 (spatter) R-369. Existing ng granule surfaced BUR or granule surfaced SBS or APP modified bitumen over steel d TPO Fleece -Back Membrane / GAF 2-Part (spatter), LRF-XF (spatter) or OB500 -120.0 dec r) (spatter) R-370. Existing smooth or granule surfaced SBS modified bitumen or existing granule surfaced EverGuard TPO Fleece -Back Membrane / GAF 2-Part (spatter), LRF-XF (spatter) or OB500 -337.5 APP modified bitumen over structural concrete deck (spatter) R-371. Existing asphaltic granule surfaced roof cover over structural concrete deck EverGuard TPO Fleece -Back Membrane / GAF 2-Part (spatter) -497.5 R-372. Existing asphaltic granule surfaced roof cover over structural concrete deck EverGuard TPO Fleece -Back Membrane / Hot Asphalt -405.0 NEMO ETC, LLC Evaluation Report 01506.09.05-R47 for FL5293-1146 certificate of Authorization #32455 Th Edition (2020) FBC NON-HVHZ EVALUATION Revision 47: 06/07/2021 02019 NEMO ETC, LLC GAF EverGuard TPO Single -Ply Roof Membrane Systems; (800) 766-3411 Appendix 1, Page 156 of 156