Loading...
HomeMy WebLinkAboutDESSIGN PRESSURE CALCULATIONSLEVINSON BUtlycor-%T ALL-AMERICAN STORM IDEFENSE I N U T 1 1 1 1 \ OLAIS Information Owner: EMILIO A REYES Address: 5205 ARMINA PLACE FT PIERCE, FL 34951 Information Wind Zone: 170 MPH. Exposure Category: B Minimum Building Dimension: 35 ft. Mean Roof Height: 15 ft. Risk Category: H Design Pressure Calculations Opening Number J1 Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) 11 Max Negative Pressure (psf) --1 - . -- Int 62 65 ___-7_ 29.1 -31.7__ 2 Int 48 65 7 29.6 -32.2 3 Int 48 65 7 29.6- -32.2 4 Int 62 65 7 29.1 -31.7 5 Int 82 84.5 7 28.0 -30.6 6 End 62 65 7 29.1 -37.6 7 Int - -62 --- 65 7 29.1 -31.7 8 Int 48 65 7 29.6 -32.2 9 Int 7 29.6 -32.2 10 Int 48 65 7 29.6 -32.2 11 Int - 7 29.6 -32.2 - -- -- Prepared in -accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1