HomeMy WebLinkAboutEnergy Code..<
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional
Regulation - Residential Performance
Method
Project Name: Lot 64 Block 1 Waterstone 2000 BGL
Builder Name: ADAMS HOMES
Street: 8613 Merano Street
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Types 1941.1 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1428.20 ftZ
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 288.56 ftZ
c. Frame - Wood, Exterior
R=13.b 224.40 ftZ
4. Number of Bedrooms 4
d. N/A
R= ftZ
5. Is this a worst case? No
11. Ceiling Types (2104.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2004.00 ftZ
6. Conditioned floor area above grade (ftZ) 2004
b. Under Attic (Vented)
R=19.0 100.00 ftZ
Conditioned floor area below grade (ftZ) 0
c. N/A
R= ftZ
7. Windows(193.0 sqft.) Description Area
12. Ducts
R ftZ
a. U-Factor: Dbl, U=0.33 129.50 ftZ
a. Sup: Attic, Ret: Main, AH: Main
6 400.8
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ftZ
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55 17.78 ftZ
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 4.940 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.275
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ftZ
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2004.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ftZ
b. Conservation features
b. N/A R= ftZ
None
c. N/A R= ftZ
16. Credits
Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 60.76
PASS
Total Baseline
Loads: 61.25
I hereby certify that the plans an ations covered b
Revie - f the plans and
• ..
this calculation are in co Iplia e t e F orid rgy
specifications covered by this
0��59?g ,
' '✓ g p
Code.
calculation indicates compliance
��
with the Florida Energy Code.
rinr''�• ,��' r ��,� O.
PREPARED BY:
DATE: Mhnn
Before construction is completed
08-08-9Q91 Kennngny
this building inspected will be i for
'f
�, , ._ ,. � ., '• .,�,
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes..
5
with the Florida SRwde.
CpD•
OWNER/AQEDLT�---� �a
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection
Checklist in accordance with R402.4.1.1
and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage
to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.070 Qn for whole house.
6/8/2021 11:37 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4
�=
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 64 Block 1 Waterstone 20 Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2004
Lot #
64-1
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
"
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
8613 Marano Street
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
V
Design Location TMY Site
97.5 % 2.5 %
Winter Summer
Degree Days
Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI
39 90
70 75
299
58 Medium
BLOCKS
Number Name Area Volume
1
Block1 2004 18837.6
SPACES
Number Name Area Volume
Kitchen Occupants
Bedrooms InfilID Finished
Cooled Heated
1
Main 2004 18837.6
Yes 5
4 1
Yes
Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 181.9 ft 0
2004 ft2 ---- 0.35
0 0.65
ROOF
/
Roof
Gable Roof
Rad Solar
SA Emitt
Emitt Deck Pitch
V
# Type Materials Area
Area Color
Barr Absor. Tested
Tested Insul. (deg)
1 Gable or Shed Composition shingles 2241 ftz
502 ft2 Medium
N 0.85
N 0.85
No 0 26.57
ATTIC
/
�/
# Type Ventilation
Vent Ratio (1 in)
Area RBS
IRCC
1 Full attic Vented
300 2004 ft2 N
N
CEILING
# Ceiling Type Space
R-Value Ins Type Area
Framing Frac
Truss Type
1 Under Attic (Vented) Main
30 Blown
2004 ft2
0.11
Wood
2 Under Attic (Vented) Main
19 Batt
100 ft2
0.11
Wood
6/8/2021 11:37 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width Height
-
Sheathing Framing Solar Below
o
1 E
Exterior Concrete Block - Int Insul Main
4.1 53 7 9 7 513.5 ft2
0
0 0.6
0
2 N
Exterior Concrete Block - Int Insul Main
4.1 20 0 9 4 186.7 ft2
0
0 0.6
0
3 W
Exterior Frame - Wood Main
13 25 2 8 11 224.4 ft2
0
0.23 0.6
0
4 W
Exterior Concrete Block - Int Insul Main
4.1 39 0 9 4 364.0 ft2
0
0 0.6
0
5 S
Exterior Concrete Block - Int Insul Main
4.1 37 4 9 9 364.0 ft2
0 0.6
0
6 -
Garage Frame - Wood Main
13 30 11 9 4 288.6 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
- Wood Main
None .25 2
8
6 8
17.8 ft2
2
N Insulated Main
None .25 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp Area Depth
Separation
Int Shade
Screening
1
E 1 Vinyl Low-E Double Yes
0.33 0.31 N 13.3 ft2 1 ft 5 in
0 ft 9 in
None
None
2
E 1 Vinyl Low-E Double Yes
0.33 0.23 N 16.2 ft2 1 ft 5 in
0 ft 9 in
None
None
3
N 2 Vinyl Low-E Double Yes
0.33 0.21 N 32.4 ft2 1 ft 5 in
4 ft 0 in
None
None
4
W 3 Vinyl Low-E Double Yes
0.33 0.23 N 32.4 ft2 1 ft 5 in
0 ft 9 in
None
None
5
S 5 Vinyl Low-E Double Yes
0.55 0.7 N 17.8 ft2 11 ft 8 in
1 ft 0 in
None
None
6
S 5 Vinyl Low-E Double Yes
0.33 0.23 N 32.4 ft2 1 ft 5 in
0 ft 9 in
None
None
7
S 5 Vinyl Low-E Double Yes
0.33 0.23 N 48.6 ft2 11 ft 8 in
0 ft 9 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
754 ft2 754 ft2
64 ft 8 ft
1
INFILTRATION
# Scope
Method SLA CFM 50 ELA EgLA ACH
ACH
50
1 Wholehouse Proposed ACH(50) .000418 2197.7
120.57 226.36 .1348
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5 34.6 kBtu/hr
1
sys#1
6/8/2021 11:37 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4
..
FORM R405-2020
# System Type
1 Central Unit/
# System Type SubT
1 Electric None
FSEC
Cert # Company Name
None None
RY CHECKLIST
COOLING SYSTEM
Ouorype suDtype ttticiency Capacity Air Flow SHR Block Ducts
Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1
HOT WATER SYSTEM
Location EF Cap Use SetPnt Conservation
Garage 0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
Collector Storage
System Model # Collector Model # Area Volume FEF
ftz
DUCTS
/
---- Supply ----
---- Return ---
Air
CFM 25
CFM25
HVAC #
�/ # Location R-Value Area
Location
Area
Leakage
Type
Handler
TOT
OUT QN
RLF
Heat Cool
1
Attic
6 400.8 ft
Main
100.2 ft
Proposed Qn
Main
--- cfm
140.3 cfm 0.07 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Heating
Venting
Jan
f X Jan
Feb
f XFeb
Mar
A r
f
Ma
MaY
X Jun
f Jun
X Jul
4 Jul
X Aug
f Aug
Se
�xjSep
Oct
f Oct
Nov
Nov
Dec
Dec
[ Jan
[ Feb
XMaAPr
X Mar
[
A r
[
Ma
[ Jun
[ Jul
[ Au
Se
[
Oct
X Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
80
80
80
80
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Main
6/8/2021 11:37 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
8613 Merano Street, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1428.20 ftz
b. Frame - Wood, Adjacent
R=13.0
288.56 ftz
3. Number of units, if multiple family
1
c. Frame - Wood, Exterior
R=13.0
224.40 ftz
4. Number of Bedrooms
4
d. N/A
R=
ftz
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2004.00 ftz
6. Conditioned floor area (ftz)
2004
b. Under Attic (Vented)
R=19.0
100.00 ftz
7. Windows" Description
Area
RDucts,
a. U-Factor: Dbl, U=0.33
129.50 ftZ
12•location & insulation level
R ftz
a. Sup: Attic, Ret: Main, AH: Main
6 400.8
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
32.38 ftZ
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
17.78 ftZ
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.70
d. U-Factor: other (see details)
13.33 ftZ
SHGC: other (see details)
14. Heating systems
kBtulhr
Efficiency
a. Electric Heat Pump
34.6
HSPF:8.50
Area Weighted Average Overhang Depth:
4.940 ft.
Area Weighted Average SHGC:
0.275
8. Skylights Description
Area
15. Hot water systems
Cap:
40 gallons
a. U-Factor(AVG): N/A
ftz
a. Electric
EF: 0.94
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
2004.00 ftz
Credits (Performance method)
Pstat
b. N/A
R=
ftz
c. N/A
R=
ftz
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signatur . Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/8/2021 11:37 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1