Loading...
HomeMy WebLinkAboutEnergy Code..< FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 64 Block 1 Waterstone 2000 BGL Builder Name: ADAMS HOMES Street: 8613 Merano Street Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types 1941.1 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1428.20 ftZ 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 288.56 ftZ c. Frame - Wood, Exterior R=13.b 224.40 ftZ 4. Number of Bedrooms 4 d. N/A R= ftZ 5. Is this a worst case? No 11. Ceiling Types (2104.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2004.00 ftZ 6. Conditioned floor area above grade (ftZ) 2004 b. Under Attic (Vented) R=19.0 100.00 ftZ Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 7. Windows(193.0 sqft.) Description Area 12. Ducts R ftZ a. U-Factor: Dbl, U=0.33 129.50 ftZ a. Sup: Attic, Ret: Main, AH: Main 6 400.8 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ftZ 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.55 17.78 ftZ SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 4.940 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.275 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ftZ 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2004.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ftZ b. Conservation features b. N/A R= ftZ None c. N/A R= ftZ 16. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 60.76 PASS Total Baseline Loads: 61.25 I hereby certify that the plans an ations covered b Revie - f the plans and • .. this calculation are in co Iplia e t e F orid rgy specifications covered by this 0��59?g , ' '✓ g p Code. calculation indicates compliance �� with the Florida Energy Code. rinr''�• ,��' r ��,� O. PREPARED BY: DATE: Mhnn Before construction is completed 08-08-9Q91 Kennngny this building inspected will be i for 'f �, , ._ ,. � ., '• .,�, compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes.. 5 with the Florida SRwde. CpD• OWNER/AQEDLT�---� �a BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.070 Qn for whole house. 6/8/2021 11:37 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4 �= FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 64 Block 1 Waterstone 20 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2004 Lot # 64-1 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: " Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8613 Marano Street Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2004 18837.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2004 18837.6 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 181.9 ft 0 2004 ft2 ---- 0.35 0 0.65 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2241 ftz 502 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / �/ # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2004 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2004 ft2 0.11 Wood 2 Under Attic (Vented) Main 19 Batt 100 ft2 0.11 Wood 6/8/2021 11:37 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height - Sheathing Framing Solar Below o 1 E Exterior Concrete Block - Int Insul Main 4.1 53 7 9 7 513.5 ft2 0 0 0.6 0 2 N Exterior Concrete Block - Int Insul Main 4.1 20 0 9 4 186.7 ft2 0 0 0.6 0 3 W Exterior Frame - Wood Main 13 25 2 8 11 224.4 ft2 0 0.23 0.6 0 4 W Exterior Concrete Block - Int Insul Main 4.1 39 0 9 4 364.0 ft2 0 0 0.6 0 5 S Exterior Concrete Block - Int Insul Main 4.1 37 4 9 9 364.0 ft2 0 0.6 0 6 - Garage Frame - Wood Main 13 30 11 9 4 288.6 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 - Wood Main None .25 2 8 6 8 17.8 ft2 2 N Insulated Main None .25 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 1 ft 5 in 0 ft 9 in None None 2 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 5 in 0 ft 9 in None None 3 N 2 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 5 in 4 ft 0 in None None 4 W 3 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 5 in 0 ft 9 in None None 5 S 5 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 11 ft 8 in 1 ft 0 in None None 6 S 5 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 5 in 0 ft 9 in None None 7 S 5 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 11 ft 8 in 0 ft 9 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 754 ft2 754 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000418 2197.7 120.57 226.36 .1348 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 6/8/2021 11:37 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 .. FORM R405-2020 # System Type 1 Central Unit/ # System Type SubT 1 Electric None FSEC Cert # Company Name None None RY CHECKLIST COOLING SYSTEM Ouorype suDtype ttticiency Capacity Air Flow SHR Block Ducts Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM Location EF Cap Use SetPnt Conservation Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM Collector Storage System Model # Collector Model # Area Volume FEF ftz DUCTS / ---- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 400.8 ft Main 100.2 ft Proposed Qn Main --- cfm 140.3 cfm 0.07 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Heating Venting Jan f X Jan Feb f XFeb Mar A r f Ma MaY X Jun f Jun X Jul 4 Jul X Aug f Aug Se �xjSep Oct f Oct Nov Nov Dec Dec [ Jan [ Feb XMaAPr X Mar [ A r [ Ma [ Jun [ Jul [ Au Se [ Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Main 6/8/2021 11:37 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 8613 Merano Street, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1428.20 ftz b. Frame - Wood, Adjacent R=13.0 288.56 ftz 3. Number of units, if multiple family 1 c. Frame - Wood, Exterior R=13.0 224.40 ftz 4. Number of Bedrooms 4 d. N/A R= ftz 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 2004.00 ftz 6. Conditioned floor area (ftz) 2004 b. Under Attic (Vented) R=19.0 100.00 ftz 7. Windows" Description Area RDucts, a. U-Factor: Dbl, U=0.33 129.50 ftZ 12•location & insulation level R ftz a. Sup: Attic, Ret: Main, AH: Main 6 400.8 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ftZ SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 17.78 ftZ a. Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.70 d. U-Factor: other (see details) 13.33 ftZ SHGC: other (see details) 14. Heating systems kBtulhr Efficiency a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average Overhang Depth: 4.940 ft. Area Weighted Average SHGC: 0.275 8. Skylights Description Area 15. Hot water systems Cap: 40 gallons a. U-Factor(AVG): N/A ftz a. Electric EF: 0.94 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ftz Credits (Performance method) Pstat b. N/A R= ftz c. N/A R= ftz I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signatur . Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/8/2021 11:37 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1