HomeMy WebLinkAboutEnergy CodeF
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 175 Phase 3 Waterstone 1512 BGL
Builder Name: ADAMS HOMES
Street: 5325 Vespera Street
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type41641.9 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1347.00 ftZ
-b. Frame - Wood, Adjacent
R=13.0 294.94 ftZ
3. Number of units, if multiple family 1
c. N/A
R= ftZ
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1512.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1512.00 ftZ
6. Conditioned floor area above grade (ftZ) 1512
b. N/A
R= ftZ
Conditioned floor area below grade (ftZ) 0
c. N/A
R= ftZ
7. Windows(174.2 sgft.) Description Area
12. Ducts
R ftZ
a. Sup: Attic, Ret: Main, AH: Main
6 302.4
a. U-Factor: Dbl, U=0.33 118.38 ftZ
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 35.00 ftZ
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55 17.78 ftZ
SHGC: SHGCng
Area Weighted Average Overhang Depth: 3.801 ft.
D
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.275
a. Electric Heat Pump
28.2 HSPF:8.50
S. Skylights Area
c. U-Factor:(AVG) N/A ftZ
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1512.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1512.00 ftZ
b. Conservation features
b. N/A R= ftZ
None
c. N/A R= ftZ
16. Credits
Pstat
Total Proposed Modified Loads: 48.62
Glass/Floor Area: 0.115
PASS
Total Baseline Loads: 50.05
I hereby certify that the plan d ifications covere
Re ' w of the plans and
SrATB
this calculation are in com is ith the Flo ' nergy
specifications covered by this
O�T1iB
Code.
calculation indicates compliance
with the Florida Energy Code.
ti �hr�l: ���, ,,:.,= ;O-
PREPARED BY:
Before construction is completed
.,•"�,,,
DATE: nR-08-9n9 l Winn KPnman
this building will be inspected for
- - .
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
�y.S
with the Florida'OD
WE'D
OWNER/AGF T• , _ _ _ _
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
• certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
r-
6/8/2021 2:25 PM IEnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORMR405-2020 INPUT SUMMARY CHECKLIST REPQRT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 175 Phase 3 Waterstone Bedrooms: 3
User Conditioned Area: 1512
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Lot Information
Lot # 175-3
Block/Subdivision: Waterstone
PlatBook:
Street: 5325 Vespera Street
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL , 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1512 13608
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1512 13608 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0
1512 ft2 ---- 0.47 0 0.53
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1691 ft2 378 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
v #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1512 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1512 ft2 0.11 Wood
6/8/2021 2:25 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORWR405-2020 INPUT SIIMMARY r_WI=rKI IRT RIFPr)RT
WALLS
Adjacent
Spacelie
Cavity Width
FtFt
Height
inArea
Sheathing Framing Solar Below
R-Stalue
1
N
Exterior
Concrete Block - Int Insul
Main
4.1 39
10
8 9
348.5 ft2
0
0 0.6
0
2
r
SW
Exterior
Concrete Block - Int Insul
Main
4.1 2
3
8 0
18.0 ft2
0
0 0.6
0
3
W
Exterior
Concrete Block - Int Insul
Main
4.1 18
1
8 3
149.2 ft2
0
0 0.6
0
4
SW
Exterior
Concrete Block - Int Insul
Main
4.1 2
3
8 0
18.0 ft2
0
0 0.6
0
5
NW
Exterior
Concrete Block - Int Insul
Main
4.1 53
7
8 7
459.9 ft2
0
0 0.6
0
6
E
Exterior
Concrete Block - Int Insul
Main
4.1 41
2
8 7
353.3 ft2
0
0 0.6
0
7
Garage
Frame - Wood
Main
13 35
9
8 3
294.9 ft2
0
0.23 0.01
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated
Main
None
.25
3
6 8
20 ft2
2
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
13 ft 0 in
1 ft 4 in
None
None
2
N 1
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
None
3
SW 2
Vinyl Low-E Double
Yes
0.33 0.21
N
10.0 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
None
4
W 3
Vinyl Low-E Double
Yes
0.33 0.31
N
3.0 ft2
7 ft 4 in
0 ft 9 in
Drapes/blinds
None
5
W 3
Vinyl Low-E Double.
Yes
0.33 0.21
N
15.0 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
6
SW 4
Vinyl Low-E Double
Yes
0.33 0.21
N
10.0 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
7
NW 5
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
8
NW 5
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
None
9
E 6
Vinyl Low-E Double
Yes
0.33 0.23
N
30.0 ft2
8 ft 4 in
0 ft 10 in
Drapes/blinds
None
10
E 6
Vinyl Low-E Double
Yes
0.33 0.23
N
23.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
11
E 6
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
390 ft2 390 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .0004
1587.6 87.1
163.52
.1324
7
6/8/2021 2:25 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORIVt R405-2020 INPI IT SI IMMARY rHFrKi icT PPDr%DT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5
28.2 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftz
DUCTS
---- Supply ----
V
---- Return ----
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic 6 302.4 ft
Main
75.6 ftz Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan Feb Mar
Heating H Jan H Feb MarApr
A r
Jul
May Jun Jul
Ma ri
Jun rl
Au
AuSep
rl
Se
rl
Oct
Oct
Nov
Nov
Dec
Dec
Ventin Jan Feb[X Mar
[
Apr [
May JunJul
Aug
Se [X]
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2
3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM 78
78
78
78 78 78
78
78 80
80
80
80
PM 80
80
78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM 78
78
78
78 78 78
78
78 78
78
78
78
PM 78
78
78
78 78 78
78
78 78
78
78
78
Heating (WD) AM 66
66
66
66 66 68
68
68 68
68
68
68
PM 68
68
68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM 66
66
66
66 66 68
68
68 68
68
68
68
PM 68
68
68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 lbs/sci.ft.
0 ftz
0 ft
0.3
Main
6/8/2021 2:25 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4
FOR4v1 R405-2020
ir
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
5325 Vespera Street, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1347.00 ft2
b. Frame - Wood, Adjacent
R=13.0
294.94 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
3
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1512.00 ft2
6. Conditioned floor area (ft2)
1512
b. N/A
R=
ft2
7. Windows- Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
118.38 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 302.4
b. U-Factor: Dbl, U=0.33
35.00 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
17.78 ft2
a. Central Unit
28.4 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: other (see details)
3.00 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
3.801 ft.
a. Electric Heat Pump,
28.2
HSPF:8.50
Area Weighted Average SHGC:
0.275
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2EF:
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
0.94
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1512.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on inst@flgd Code compliant features.
Builder Signat Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/8/2021 2:25 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1