HomeMy WebLinkAbout20806 Glades cut-off FASTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL PERMIT #: DATE PAID: FEE PAID: RECEIPT #: 25.00 56-SF-08256 DOCUMENT #:FI1700693 AP1481347APPLICATION #: 56-PID-4669378 09/15/2020 LOT: ID#: BLOCK: SUBDIVISION: APPLICANT:Tommy Buchmeyer AGENT: PROPERTY ADDRESS:20806 Glades-Cut-Off Rd Port Saint Lucie, FL 34987 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. [01] TANK SIZE[][1]1050.00 [2] [02] TANK MATERIAL[]Concrete [03] OUTLET DEVICE[] [04] MULTI-CHAMBERED[][Y ]N/ [05] OUTLET FILTER[] [06] LEGEND[] [07] WATERTIGHT[] [08] LEVEL[] [09] DEPTH TO LID[] TANK INSTALLATION [27] SURFACE WATER[] SETBACKS FT [28] DITCHES[]FT [29] PRIVATE WELLS[]100 FT [30] PUBLIC WELLS[]FT [31] IRRIGATION WELLS[]FT [32] POTABLE WATER []74 FT [33] BUILDING FOUNDATIONS[]6 FT [34] PROPERTY LINES[]20 FT [35] OTHER[]FT [10] AREA[][1]679 [2] [11] DISTRIBUTION[] [12] NUMBER OF DRAINLINES[] [13] DRAINLINE SEPARATION[] [15] DEPTH OF COVER[] [16] ELEVATION [] [17] SYSTEM LOCATION[] [18] DOSING PUMPS[] [19] AGGREGATE SIZE[] DRAINFIELD INSTALLATION SQFT BOX HEADER X [ABOVE ]BMBELOW/1.00 [14] DRAINLINE SLOPE[] [20] AGGREGATE EXCESSIVE FINES[] [21] AGGREGATE DEPTH[] [36] DRAINFIELD COVER[] FILLED / MOUND SYSTEM [37] SHOULDERS[] [38] SLOPES[] [39] STABILIZATION[]09/23/2021 [40] UNOBSTRUCTED AREA[] ADDITIONAL INFORMATION [41] STORMWATER RUNOFF[] [42] ALARMS[] [43] MAINTENANCE AGREEMENT[] [44] BUILDING AREA[] [45] LOCATION CONFORMS WITH SITE PLAN[] [46] FINAL SITE GRADING[] [47] CONTRACTOR[]Jamie DiFrancesco (All Contr [48] OTHER[]INFILTRATOR Quick4 Plus EQ36 LP [49] TANK PUMPED[] ABANDONMENT [50] TANK CRUSHED & FILLED[] [22] FILL AMOUNT[] FILL / EXCAVATION MATERIAL [23] FILL TEXTURE[] [24] EXCAVATION DEPTH[] [25] AREA REPLACED[] [26] REPLACEMENT MATERIAL[] Polylok PL-68 1.2. 1.2.10.00 28-O15-03DC4 4221-2120040-000-4 Comments are on page 2.Comments: CONSTRUCTION []:/CHD DATE: DISAPPROVED St. Lucie 07/06/2021APPROVED Environmental Specialist I Matthew S Vajanyi (Florida Department of He FINAL SYSTEM []:/CHD DATE:DISAPPROVED St. Lucie 09/23/2021 Environmental Specialist III Brian J Ingram (ENVIRONMENTAL HEALTH) APPROVED (Explanation of Violations on following page) EH Database v 1.0.1 AP1481347 EID350183 Page 2 of 3 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL PERMIT #: DATE PAID: FEE PAID: RECEIPT #: 25.00 56-SF-08256 DOCUMENT #:FI1700693 AP1481347APPLICATION #: 56-PID-4669378 09/15/2020 Violation Number Comment The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST, filter, and 10x6 long BED DF installed. No violations, system ok to cover. Contractor notified by phone. Needs final inspection for gutters, mound system, and final site grading. Final system approved. Contractor and building department emailed final approval. Comments EH Database v 1.0.1 AP1481347 EID350183 Page 2 of 3 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC