Loading...
HomeMy WebLinkAboutLetter; Plan Approvalvr TOLNTNINRNGLC STUCUGLRRAENGINEERS December 22, 2020 Mr. Thomas Campbell Florida Department of Business and Professional Regulation 2601 Blair Stone Road, Building C Tallahassee, Florida 32399-6563 RE: Plan Approval Lark Builders Plan # LB-S-LBE-170D-20 Dear Mr. Campbell, Pursuant to the requirements of the Department of Business & Professional Regulation, the above referenced documents have been reviewed for compliance with: 2020 Florida Building Code, 7rh Edition 2017 National Electrical Code (NFPA-70) Florida Product Approval Rule 61 G20-3.006 (FAC) All mandatory comments have been satisfied and plans are approved for construction by a currently approved modular building manufacturer. These documents were reviewed for only what is to be constructed in the factory. Any work performed at the site, such as the foundation, is under the authority and jurisdiction of the local Building Official. Third Party Agency approval in no way alleviates the builder/manufacturer from complying with all the applicable codes, which may or may not be identified in this review. Approval also does not preclude the local building official from requiring work be performed that was not previously reviewed, approved, and constructed under the State of Florida's Manufactured (Modular) Building Program to make the building, code compliant, for the intended use. A signed and sealed set of plans are maintained on file with Top Line Engineering, LLC. If you require my assistance in any way, please do not hesitate to contact me. Thank you. Res ectfully, illiam E. Neary, 1 Business Partner Top Line Engineering, LLC BILL.TLE@yahoo.com *** Please note: Any questions regarding local permitting should be directed to the Manufacturer. The Manufacturer's contact information can be found in the title block of the plans. 10649 Oakview Pointe Terrace • Gotha • FL 34734 • Phone (407) 421-4037 • Projects.TLE@yahoo.com FL Certificate of Authorization 31785 co 0 O I U] W Q PTIONAL PORCH-4' OR 6'-1 50'-0" MAXIMUM BUILDING LENGTH — 30'-0" MAX FOR VAULTED ROOF — DUA RIO—U-INUNI — 29 GAUGE STEEL AG PANEL — STANDING SEAM STEEL — ASPHALT SHIGLES TO LINE ENGINEERING LLC STRUCTURAL EN GINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 MAXIMUM DESIGN PRESSURES 170mph BASIC WIND SPEED 1 1 2n I 2r I2e 3r 3e 4 5 ZONE [+21.8. —482 131.9 115.2 +17.4+17.4 —62.6 —24.7 +31.9 1369 31. +31.9 +31.9 —35.5 +38.2 —48.4 "'Please noPe i4ny questions.regarding lgcgl p'erff1#q ;should.be dir'ecied fo fhe.Mbnufacfuier` -Thd,-Mchufodurer's contact"infoimdHon 6anbe'f6.und.1*t ie HUb blockof fhe:plans. APPROVED FOR HVHZ FBC 1626.1 EXCEPTION: F. STORAGE SHEDS THAT ARE NOT DESIGNED FOR HUMAN HABITATION AND THAT HAVE A FLOOR AREA OF 720 SQUARE FEET (67 M2) OR LESS ARE NOT REQUIRED TO COMPLY WITH THE MANDATORY WINDBORNE DEBRIS IMPACT STANDARDS OF THIS CODE 409 DIXON STREET VIDALIA, GEORGIA 30474 PHONE NUMBER: (912) 538-1888 CODE INFORMATION COOS ufl190x '-• ]I.YnfKiIRER BIaDo]O 1]PE Ch 1WCIlOx THE f� I+xRrtcaW+ Ira¢ ]XY 91FwASWx SRIEY OCCIPNLT Yam et30Y]9£ roAOFA K SORXS ta�omxE Ext]DSaI2 Remm caWw. PIm9JRE rrona] c F�clw AooE wo uvo RaOT us Lao RaaR oTAo Aow Ioov w Raea Ia'E LOGO n/G]fa9 'R' M]NO YE 1MLLS FLOOR. RODE W� Y®IAS iFA aepNxO IAIWS�xE PFaIECaax a5]OE M 'E vEUEF 1lvrE SO W E i00TCE ]i/ mn. a Iffi GENERAL NOTES 1. FOUNDATION PLANS ARE NOT PART OF THIS PLAN SET AND ARE GOVERNED BY LOCAL JURISDICTION. 2. BUILDINGS ARE APPROVED FOR RESIDENTIAL LAWN STORAGE ONLY 3. THIS BUILDING IS EXEMPT FROM THE FECC PER SECTIONS RIOI.4.2.4, R402.1. 4. REFER TO TIE DOWN DETAILS FOR PROPER INSTALLATION REQUIREMENTS TO MEET CODE. S. ALL LUMBER FOR CONSTRUCTION WILL BE 12 SYP EXCEPT AS NOTED. Ld > Q Ld X 03 0 q dv.i Br.LRg 6. CURERS SHALL BE SITE INSTALLED PER THE LOCAL AUTHORITY HAVING JURISDICTION AND PERMITTING REQUIREMENTS. 7. ALL WINDOWS AND DOORS TO MEET THE MINIMUM SPECIFICATIONS PER THE APPROVED PLANS AND THE FLOM BUILDING CODE B.IN ACCORDANCE WITH FSC 1609.1.2. -STORAGE SHEDS THAT ARE NOT DESIGNED FOR HUMAN HABITATION AND THAT HAVE A FLOOR AREA OF 720 SQUARE FEET OR LESS ARE NOT REQUIRED TO COMPLY WITH THE MANDATORY WINDBORNE DEBRIS IMPACT STANDARDS OF THIS CODE-. 9.IN ACCORDANCE WITH RIC 1010.1.1. EXCEFRGN (10.) BUILDINGS THAT ARE 400 SO -FT OR LESS AND THAT ARE INTENDED FOR USE IN CONJUNCTION WITH ONE- AND TWO-FAMILY RESIDENCES ARE NOT SUBJECT TO THE DOOR HEIGHT AND WIDTH REQUIREMENTS OF THIS CODE. STRUCTURES 400 SO -FT OR MORE SHALL HAVE AN 80" MINIMUM DOOR. 10. IN ACCORDANCE WITH FLORIDA STATUTE 553.80 (I)D. LAWN STORAGE BUILDINGS AND O� 11-15-20 5cmc NTS M-1: LB-S-LEE-170D \\ \1111111/ \\ // %% EW T `�� �•.. ••••••••..,•'9 % ;• �� /.:• V%CENSE- ''•,�jy�� STORAGE SHEDS BEARING THE INSIGNIA OF APPROVAL OF THE DEPARTMENT ARE NOT SUBJECT TO 553.842 (FLORIDA PRODUCT APPROVALS) BUT SHALL MEET THE DESIGN WIND LOAD REQUIREMENTS OF THE 2020 FBC 7TH EDITION. 11. FLAT METAL STRAPS CAN BE BENT AROUND STRUCTURAL MEMBERS OF WALL STUDS, TRUSSES. CHORDS. ETC. TO HELP SECURE THESE MEMBERS. PROVIDED THAT THE ADDED BEND DOES NOT INTERFERE WITH ANY OF THE EXISTING BREAKS/BENDS IN THE STRAP. 12. AS PER FBC SECTION 1626.1 EXCEPTION IF): STORAGE SHEDS THAT ARE NOT DESIGNED FOR HUMAN HABITATION AND THAT RAVE A FLOOR AREA OF LESS THAN 720 SQUARE FEET OR LESS ARE NOT REQUIRED TO COMPLY WITH THE MANDATORY WINDBORNE DEBRIS IMPACT STANDARDS OF THIS CODE 3COMPONENTS/CLADDING ARE IN COMPLIANCE WITH THE 2020 RIC 7TH EDITION. ,3D 14. SHEDS LOCATED IN FLOOD HAZARD AREAS MUST COMPLY WITH THE LOCAL FLOOD ZONE/'11111110 15. IF A WALL IS FRAMED FOR FUTURE HVAC UNITS THAT WILL BE APPROVED BY THE AH/ W (n I I— � ,� / NO. •� Z i = 64608 *; �• ;�•� -0: �'.. STATE t 4U j p,I. F '(V �j .(�'..•• 0 R I /� FS •'••"••••••• •.. ; \4G � ' " \\\� AND LOCAL REQUIREMENTS FOR PERMITTING. 16. WINDOWS AND DOORS INSTALLED BY THE CUSTOMER ARE REQUIRED TO HAVE APPROVAL OF THE LOCAL AHI AND LOCAL PERMITTING REQUIREMENTS. 17' HVHZ BO COMPONENTS FOR SHEDS REQUIRE THAT INSTALLATION PER MANUFACTURERS 0 9INSTRUCOfSNeeL• Mn1Ue� T. BRIa.iR P.E. RoriEa Ueeam 64608 FBPR-1 OF 7 2020-12-22 TOP LINE ENGINEERING APPROVAL PLAN # LB-S-LBE-170D-20 *** HVHZ APPROVED 3.5"-20GA METAL COLLAR TIE, 4'-0" LONG ATTACHED WITH (2) #10 SELF DRILLING GRABBAR SCREWS EACH SIDE SEE ROOF FRAMING SCHEDULE FOR RAFTER AND BRACING SPACING —VARIES, 6*-0" TO FRAME SECTION 409 DIXON STREET VIDALIA, GEORGIA 30474 ATTACH ROOF FRAMING TO TOP PLATE OF WALL FRAMING PHONE NUMBER: (912) 538-1 WITH BUILDEX 10-16X1 T. PANHEAD SCREWS WITH #3 DRILL CODE MFOR..N POINT AT 6" O.C. ROOF PANELS FASTENED WITH .25"-14x.75" HWH TRAXX/1 SEE ROOF FRAMING AT 6" O.C. SCHEDULE FOR RAFTER AND BRACING SPACING 3.5-20GA METAL STUDS SPACED AT 24" O.0 MAX. OVERHANG OPTION DETAIL 0GA METAL STUDS, SPACED AT 24" O.0 MAX. SPACE 3.5' BRACE AT 3*—D" ABOVE FINISHED FLOOR, ATTACH TO EACH STUD W/(2) #10 SELF DRILLING GRABBER SCREWS, (1) INTO EACH FLANGE SHEATHING FASTENED W/ #8x1.5" GRABBER SCREW (OR ATTACH ROOF FRAMING TO EQUAL) AT 6" O.C. TOP PLATE OF WALL FRAMING WITH BUILDEX 10-16X1 TEKS PANHEAD SCREWS WITH #3 DRILL - POINT AT 6" D.C. ________------------ _______ __ ___ __ _________ —III SEE ROOF FRAMING I SCHEDULE FOR BRACINNG SPAC NG TO fi —I TOP LWE ENGINEERING LLC STRUCNRAL ENGINEERS William E. Neary, III 3.5-20GA METAL STUDS SMP-51, SMI-79, [CC 5185040 SPACED AT 24" O.0 KW. 10649 Oakview Pointe Terrace Gotha, Florida 34734 OVERHANG OPTION DETAIL COxelRll[IIO. THE Fa vxvaLsmr��� 0CQ1P�'zT unnr .Ma..ac xu�R oc sroRas awc ..m svcm w-�m.e uPosaa FxGD911S OODaar_ PR6AWC CtIGfYIIR •/- nee o.Poarw¢ F.mR R F a6�o �o ROOF DVE LaW fta011 OFM t0/D ROM WE LOra lf/M'x9 •R• wtwc oc wss. RmR. RooF w• uoaaa PLR eurtaw wRRr uc wmccroR usvc FaaaxE ' Mss REVISIONS REV DESCMnON DATE By > pam ey. MTB w I1-15-20 NTs X —I.. LB-S-LBE-170D O a g LJ Lf) J o O \\\•`�EW11 Te�Q \\\� ;• LtCENSe '• 0��� 64608 0:: S17 : �i� STATE*•. `0 R I D P j�, \\� Oii�ii���``�� M,Kh- T. Bela.ln P.E Florida License 064608 --: FBPR-2 OF 7 2020-12-22 TOP LINE ENGINEERING APPROVAL PLAN # LB-S-LBE-170D-20 *** HVHZ APPROVED WALL SHEATHING OPTIONS: BOX RIB ALUMINUM TWIN RIB ALUMINUM — DUTCH LAPSIDING ALUMINUM END WALL — DUTCH LAPSIDING STEEL SIDING SECURED WITH (2) H3 OR EQUAL — 29 GAUGE STEEL AG PANEL (RUN ANY DIRECTION) 3.5" 20GA. STEEL (SEE FASTENING SCHEDULE) — a" T-111 WOOD SIDING TOP PLATE — HARDIE PANEL STUCCO AND T-111 SIDING END WALL — HARDIE BOARD SIDING POLYCARBONATE GREENHOUSE PANELS 3.5" 2 A. STEEL BRACE W (2) 4x4 P.T. POST #10 SELI TAPPING SCREWS CH EN (1 INTO CH FLA E) / I'] J / / / 3 " 20GA. L 3.5" 20 . STEEL TEEL S E PLATE OR OR LONGERONGER STU ®24"O.C. MAX. (SEE FASTENING SCHEDUL) FLOOR FRAMING I-4'&6' OPTIONAL PORC 50'—O" MAX_ TOP LINE ENGINEERING. LLC SiRUCNRAL ENGINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 STANDARD WALL DETAIL SDMP & FASTENER SCHEDULE JAI oo� ANp ppu,« ® o Am�/pcse w„ :apanpi v rass N/A »o.a•.ms. r,An/pa� Tcopers :arA u-.pc ,-:m.0 _ SIRAV & 9-SON STRONG-ONT&OSD SCREW SCHEDULE rwu�/rcx unvT .u.�raaoi . AW.a .mf p -T —L r nrm nnn ns,omi DoaciM .m-:a gas mats •- .1 v.m�/pT� war ..Tu rcTom RppR rAsma � iainms pw a sv.A 2020-12-22 TOP LINE ENGINEERING APPROVAL PLAN # LB-S-LBE-170D-20 *** HVHZ APPROVED 409 DIXON STREET VIDALIA, GEORGIA 30474 PHONE NUMBER: (912) 538-18 cmE wmpN -� YAnsnuRLR nmanc T..c rx Rurnox TrvE str+E T»mcrnpN Rrx vwimmN smcu ocamuA� rLLpnAdE rawazR a npaus p.vc �vo srtm •.-n� oprosuac TNaDsm¢ nmsm mlDdvL p-r Cp6:YiM ./- niv mPoRTAN:E EKTOR Npf pbD 18m RJpf t1IE vL.D Rpp11 VAD LOm IImR LrvE LpvD vv/:vf9 1, M1WG oT vuRLS TLwN. Pop[ WA YpaAfS f7W [YIAGHG WRbLv.E' PRplFtiv4v pSvpE vAVUaGVZ 96TEA ISvcE moos vpm.GE av mrt. a � W p.... Dr uiB Q pW� ++-+s-zo W s� Nis X vvme/: LB—S—LEE-170D TITS /���i N11111 �i g ♦ �� .... . .... ���/• r•''. LICENSC _j N0. W W = 64608 V) STATE FTF RION p•.... %/Oj ` ``` 1 1110 J YdRAen T. BWO.in P.E ri,6da Lice— 64W8 9 «D FBPR-3 OF 7 Js NR.4C u ]•ro• •nACN TO F�.1C MD /(2) % 0 snr DFwNo ffuL®LF screws. (r) aDo FAxN rw+a 16" FFrCE AT J'-0" MIOY£ RNBRO Ei Aneol TO /(3) fl/10 srJi aauwc dUet&N uNiws, (I) Nro FAAr I ruNE slTu auur¢L-Dxe_ END WALL FRAMING OPTION END WALL FRAMING OPTION N1G YETAL BWCNG. ].J' ®TILE AT J'-0' 1 UCH FHD TO SNpJ R/ (I) e80K /CFSIa/ ROOF, CRDeJ. (II N(0 i/Cll /UNGC �mcx TO ULH STIO �/(4) /10 s¢r GWuw GFTBBCN scFLwe M YETM. BWCNG. ].5. F—C •T J'-0' 5. a1I0 UGH •ALE AnACH i0 M301E fIIO511ED t� " SEIf DFFUNG (5 BBOt REwS �� (ry Nro 61oI BAHct: L TOP LINE ENGINEERING. LLC STRUCTURAL ENGINEERS William E. Neary, III SMP-51, SMI-79, ]CC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 END WALL FRAMING OPTION END WALL FRAMING OPTION 2020-12-22 TOP LINE ENGINEERING APPROVAL PLAN # LB-S-LBE-170D-20 *** HVHZ APPROVED !OG 11ELY FR�lO, UCrr EHD TO SR45 V (:) cccws. (II Drto FAa r1/rIG6 T—may M 1 YRAL BFKNO. I (1) (J) CRLwJ, (Ij Ni0 E1CH rl/.NOE M 409 DIXON STREET VIDALIA, GEORGIA 30474 PHONE NUMBER: (912) 538-1888 CODE INFORMATION oc Uvuzr .uD..me xuemm Di siGFds eJvosaa wamNa aaLWeL PRESSIIFC cosTTamrt •/- ale wPOFfwIL fKTOR FOOT OUD lOeO ATOi lNE 180 M ROOK OUD lOW tOiY BDON Irv0 tOeO if/le•�Y 'F' WING Of N.LLlS• BOON. FOOT eVe umua PCF Iwanw Humrxc PFDenNN useec lwawav¢ sFMCF use¢ souMe roours ne Yvr. w las Rm B MTB LLI I1-15-20 Q LLJ Nts —j. LB-S-LBE-170D IIT. O SAC, ````��.N1. P' d NO. ':y: 64608 LLI Ld q ,,pSTATE % O ' Q 11 I L1 Madly T. 8.1d.i. P.E. Q Florida Lic— 64WS (Z sh— FBPR-4 OF 7 William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 SKID RUNNER SPACING* UNDER 30' LENGTH SHED WIDTH A B 6'-0" 15' 42" 8'-0" 18" 60" 10'-0" 18" 84" 11'-0" 24" 84" 11'-8" 28' 84' 13'-0" 36" 84" 13'-8" 40" 84" -VALUES ARE FROM END OF JOIST TO CENTERS OF SKIDS ONLY. wl TH JOIST SIZE!-] 6'-0" ji 2"x4" 6--1" TO 11'-8" 2"x6" > 11'-8- 2"x8- -NOTE: JOISTS CAN BE EITHER #2 S.Y.P. OR 18 GAGE STEEL CHANNELS. THE STEEL CHANNEL ACTUAL DIMENSIONS MATCH THE WOOD ACTUAL DIMENSIONS AND ARE INTERCHANGEABLE. -FLOOR SHEATHING SECURED WITH 2J'XO.113' NAIL (OR EQUAL) ® 6" O.C. MAX EDGE AND FIELD SKID RUNNER SPACING* 30' LENGTH AND GREATER SHED WIDTH A B 6'-0" 12" 24" 8'-0" 16" 32" 10'-0" 20" 40" 11'-0" 22" 44" 11'-8" 24" 46" 13'-0" 26" 52' 13'-8" 28" 56" -VALUES ARE FROM END OF JOIST TO CENTERS OF SKIDS ONLY. 2 & 3 SKID FLOOR FRAMING PLAN 2020-12-22 TOP LINE ENGINEERING APPROVAL PLAN # LB-S-LBE-170D-20 *** HVHZ APPROVED 409 DIXON STREET VIDALIA, GEORGIA 30474 PHONE NUMBER: (912) 538-18 1 xrxw.cnwEa aanxc ttiE mxsiRurnax tteE rvs mortrnox r�x stwREssox srsrtx oms+Ner .uax.alc xuReEn or stoats e.sx .Ra zE<m x'naxR ososvaE dam Rm]aYl iRFSAME co6sIDENr ./-.1. WNRWQ iCT4R RRo<R�R�.R n riORR RM MYD ,� ri4RR !M l0/n ]A/r]v9 •R• wrwc ai vuMs. nowt Roor v Raoua icR euanxc xuaaru¢ iaortcm. ia.cE xuRar a: !R R V . sauwc raoucE nv mr. a MTB �W oxu 11-15-20 Q W sm� PITS ,.,a+/: LB-S-LBE-170D o DD � W......:....... V%CENSE, '•.. /i�i •?Z� NO. W Ld 64608 = U) (n O a g1:• STATE :'4,` �i� %., 0RIDN;`•����� ''''' g I SO I I11� `\`` 0_ Maltha T. 8Rld.in P.E. O Florida U"eensysa #64608 O S sit FBPR-5 OF 7 t012" LAP SPLICE FASTENED WITH (6)Tj'x4' G SCREWS ON INSIDE, (3)T1i-x4- LAG REWS ON OUTSIDE (9 TOTAL) 437 x67 1 P.T. SKID SPLICE 1.5 SENCO K28 (OR EQUAL) NAILS, TWO ROWS 1.5' FROM THE EDGE, ® 12' O.C., STAGGER ROWS 6 3"x6" SPLICE PLATE FASTENED WITH (5)-SENCO K28 (OR EQUAL) NAILS EACH SIDE (2) 2f1x677 P.T. SKID SPLICE/SECURINGd T.30 TDP LINE ENGINEERING, — T_ �T. STRUCRIRAL ENGINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 3.5" 20GA. STEEL SOLE PLATE SECURED WITH T}"x4" LAG SCREWS 016"O.C. r 1}"x1}" NOTCH FOR EACH JOIST ATTACK JOIST TO SKID WITH A-.4" LAG SCREW OR (2) SIMPSON H-3 (OR EQUAL) AT EACH CROSSING JOIST TO SKID CONNECTION WALL SHEATHING —3.5" 20GA STEEL STUDS 016"O.C. FLOOR SHEATHING — FLOOR JOIST 2"x4" BLOCKING BETWEEN SKIDS J 2% BLOCKING BETWEEN SKIDS AT UNDER DOUBLE END JOIST BOTH ENDS SECURED TO END JOIST SECURED WITH (3) 0.120"x3- WITH (3) 0.120NY NAILS 012"O.C. NAILS 612'O.C. STAGGERED EACH SIDE STAGGERED WALL TO FLOOR CONNECTION DETAIL 2020-12-22 TOP LINE ENGINEERING APPROVAL PLAN # LB-S-LBE-170D-20 *** HVHZ APPROVED 409 DIXON STREET VIDALIA, GEORGIA 30474 PHONE NUMBER: (912) 538-1& awn< me <onmmrnax THE rPc vaorzrnox :mu � aav�ssvon ssn>, oc wucr wwei¢ xR�n � noRcs e.sc Rum swm ..-von.. m0'09iR< daosm¢ vnmwn vRawR< c<mrxmrt ./- o:a WFOR1YlE fItTOR ROOF OOD MVD ROOr IfJE tGD Noon ups MYD n/nevv 'R' Pn1N0 K RW15. MOR. ROOT n,/. �R awn< W u1B oms 11-15-20 Ws a NTS —1: LB-S-LBE-170D DO 1-1 T-'eq'���i ��%%% _% � �'•:��ii ���� :' L\CENSf NO. LLI w i 64608 STATE FIORIDP MR11Ev T. BdERin P.E. p F.d. U«n:e sasoa Sn�E FBPR-6 OF 7 ELECTRICAL SYMBOL KEY 777111 RECEPTACLE 240V 240 RECEPTACLE SINGLE POLE SWITCH THREE WAY SWITCH CEILING MOUNT LIGHT FIXTURE WALL MOUNT LIGHT FIXTURE FLUORESCENT LIGHT FIXTURE Fff JUNCTION BOX 0'-0- MAXIMUM BUILDING LENG WINDOW HEIGHT, LOCATION AND QUANTITY MAY VARY AND ARE OPTIONAL / NOTE: ALL ELECTRICAL EQUIPMENT SHOWN IS OPTIONAL AND LOCATIONS MAY VARY WITH A MAXIMUM NUMBER OF 2 LIGHTS AND 6 OUTLETS PER LAYOUTo 409 DIXON STREET VIDALIA, GEORGIA 30474 PHONE NUMBER: (912) 538-18 1 ;.I o� ~ - WuQeIYE � CODE INFORINTION wx .myox ' uuwrcEURm ErRLING lrcc cormwrnw IrPE •b Ee¢ PaalErnoh .*a „ \ ' / SEE VARIOUS END WALL N SEE VARIOUS END WALL FRAMING SECTIONS FOR J\Y//1_ FRAMING SECTIONS FOR WALL AND DOOR FRAMING \ WALL AND DOOR FRAMING / \ / w1ERA4 vR 9JxE coEiR[mR .�- u,a nrmrurt rttou ,� Pmr urt lao 'A' M11,IG K �ulF. R(IfIP. Aeer W� PEA &AlMi Mlf✓fKPl2 PAeIEtT10N 16CC ,amount 9flirlt us.cE sauuc rooncE rI Ias REVISIONS REV DESCRIPTON GATE OPTIONAL ELECTRIC TO EACH UNIT WILL BE FIELD CONNECTED FROM EXISTING POWER SOURCE ELECTRICAL NOTES: Y 1. ALL WIRE TO BE #12 THHN SOLID COPPER WITH GROUND. 2. FIXTURE LOCATION AND TYPE MAY VARY 3. PLASTIC OR METAL "NEW WORK' OUTLET BOXES 4.20A GFCI OUTLETS 5. ALL RECEPTACLES TO BE AT 12"-16" A.F.G.; MAXIMUM 8 RECEPTACLES. 6. ALL SWITCHES TO BE AT 48"-52" A.F.G. 7. FLUORESCENT & LED LIGHTS MAY SUBSTITUTE FOR INCANDESCENT LIGHTING 8. ALL OUTLETS TO BE GFCI 9. THE MAIN ELECTRICAL PANEL, FEEDERS, POWER HOOKUP TO UNIT (INCLUDING ALL DISCONNECTS, OVER CURRENT DEVICES, PANELS, GROUNDING, ETC.) IS DESIGNED BY OTHERS, SITE INSTALLED, AND SUBJECT TO LOCAL APPROVAL. RMT— RIGID METALLIC TUBING 358.30 SECURING AND SUPPORTING. EMT SHALL BE INSTALLED AS A COMPLETE SYSTEM IN ACCORDANCE WITH 300.18 AND SHALL BE SECURELY FASTENED IN PLACE AND SUPPORTED IN ACCORDANCE WITH 358.30 (A) AND (8). (A) SECURELY FASTENED. EMT SHALL BE SECURELY FASTENED IN PLACE AT LEAST EVERY (LOFT). IN ADDITION, EACH EMT RUN BETWEEN TERMINATION POINTS SHALL BE SECURELY FASTENED WITHIN (3 FT) OF EACH OUTLET BOX, JUNCTION BOX, DEVICE BOX, CABINET, CONDUIT BODY, OR OTHER TUBING TERMINATION. EXCEPTION NO. 1: FASTENING OF UNBROKEN LENGTHS SHALL BE PERMITTED TO BE INCREASED TO A DISTANCE OF (5 FT.) WHERE STRUCTURAL MEMBERS DO NOT READILY PERMIT FASTENING WITHIN (3 FT). TOP LINE ENGINEERING LLC TRUCNRAL ENGINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 2020-12-22 TOP LINE ENGINEERING APPROVAL PLAN # LB-S-LBE-170D-20 *** HVHZ APPROVED w > G E r um La Eku: 11-15-20 X c NTS X LB-S-LBE-170D I I T d % �, ................ .... z ••'.2 i �i• -J w NO. = = 64608 V) _ -13 .• SATE 13, I �i� '•. FOT0 R 10 P �� •: (�S ....... jS10 1 L F- Wtth . T. 13.fd iA P.E ei nodd, Deere 64606 w w sterol. FBPR-7 OF 7 T