Loading...
HomeMy WebLinkAboutOverall Plan ViewA \ N 1 1 \ 1 1 1 1 1 1' 1 RECEIVED ; INDIAN RIVER 1 \ WATERBODY WIDTH 8 600'+ JUL 2 3 2021 11 11 3t, LUCID 0091"Ity 1 , o Permitting p ` / ` / , x 61 \ 1m REVIEWED FOR 1 \ T. LUCUE COUNTY 64 LE 1 \ 1 \ \ii 1 ' APRROXIMATE 41 MF_p``N- HIGH WAT LINE 1 1 1 \ 1 1 63't Of DAHW 1 \ WpTERWpRD go,tO.P.• \ 1� i (see SV lvgm s) .i i ` W pR0 OF MHW TOP OF $pNK It1D1PN RIVER OR 4' X 5' LANDING ATTACHED TO 4' X 30'± RAMP TO CONNECT WITH EXISTING 10' DECK (SEE SHEETS 2 & 4 FOR DETAILS) SHORELINE LENGTH 190f L.F. ***NOTES*** - PROPOSED WORK IS TO CONSTR CTA 4' WIDE RAMP/WALKWAY TO CONNECT TO THE EXISTING 10' X 10' PLATFORM AND THE EXISTING STAIRS TO THE DO K WITH A RAMP - - DECK DESIGN LOADS TO MEET 20 0 FBC - 7TH EDITION: WIND LOAD AS PER ANSI/ASCE -16 SPEED = 170 MPH EXPOSURE = D IMPORTANCE FACTOR = 1.0 - RAMP LANDWARD OF MEAN HIGH WATER TO HAVE PICKETS WITH < 4'SPACING - ALL DOCK PILES 8"0 MARINE PILES - MIN. PENETRATION VARIES BASED UPON LOCATION (SEE PLAN DETAILS) 1?s Environmental S ervices, Inc. 1901 SW Yellowtail Avenue Port Saint Lucie, FL 34953 OVERALL PLAN VIEW Michael Mathias 7107 S. Indian River Drive Fort Pierce, Florida PCN# 3412-414-0001-000-2 0' 20' 40' HIC SCALE Paul Welch, Inc. 1984 SW Biltmore Street, #1 4 Port St. Lucie, FL 34984 'UN 3 0 2021 Paul Welch,, PE No. 29946 Phone:772-215-3997 Fax:772-879-4520 www.disenvironmentalservices.com SCALE: 1"=40' JUNE 2021 1 SHEET 1 of 6 10' O.C. (TYP.) :- A C- I. I UKUAb- I It 1 ABOVE DECK RINE PILES .T. STRINGERS 9° P.T. DECKING �. MM �CIE COUNTY O CC (2) 5/8' SS THRU BOLT (TYP) PER PILE FILE COPY 0' 1' 2' ***NOTES*** GRAPHIC SCALE ALL 8"0 MARINE DOCK PILES - MIN. PENETRATION INTO FIRM SOIL VARIES FROM 6' TO 10' LANDWARD OF MEAN HIGH WATER AND MIN. PENETRATION WATERWARD OF MEAN HIGH WATER FOR RAMP IS 10' OR AS NECESSARYTO PROVIDE ADEQUATE BEARING STABILITY 2° X 6° P.T. DECKING NOT ALL SHOWN FOR CLARITY DECKING WILL BE ATTACHED WITH #10 SS DECK SCREW X 3" ALL HARDWARE ON THE DECK AND BELOW TO BE GRADE 304 (OR BETTER) SS qSEnvironmental S ervices, Inc. 1901 SW Yellowtail Avenue Port Saint Lucie, FL 34953 TYPICAL RAMP PLAN VIEW DETAIL Michael Mathias 7107 S. Indian River Drive Fort Pierce, Florida PCN# 3412-414-0001-000-2 Paul Welch, Inc. 1984 SW Biltmore Street, # 14 Port St. Lucie, FL 34984 JUN 3 0 2D21 Paul Welch, PE No. 29945 Phone:772-215-3997 Fax:772-879-4520 www.disenvironmentalservices.com SCALE: 1" = 2' JUNE 2021 1 SHEET 2 of 6 1-1/2" 0 GRASPABLE HAND RAIL OFFSET FROM 2" X 6" WITH BRACKETS 2" X 6" VERTICAL RAIL (TOP RAIL) HAND RAIL DETAIL — TOP VIEW N.T.S. 2" X 2" PICKETS 4" O.C. (TYP) LANDWARD OF MHW (2) 5/8" SS THRU BOLTS PER PILE 2" X 8" P.T. CROSS TIE 2" X 6" P.T. TOP RAIL ATTACHED WITH (2) #14 SS SCREWS PER PILE 2" X 6" P.T. BOTTOM RAIL ATTACHED WITH (2) #14 SS SCREWS PER PILE 36" — 38" 2" X 6" P.T. DECKING 2" X 8" P.T. STRINGER (20" O.C. TYP.) IT CODE COMP ANK; BOCC VARIES ----------- 1----1-1------nnHw_ EXISTING GRADE 8"0 MARINE PILE (10' O.C. TYP.) RAMP DETAIL — SIDE VIEW '*'NOTES'"' V = 3' -ALL HARDWARE ON THE DECKAND BELOW TO BE GRADE 304 (OR BETTER) SS -ALL 8"0 MARINE DOCK PILES - MIN. PENETRATION INTO FIRM SOIL VARIES FROM 6' TO 10' LANDWARD OF MEAN HIGH WATER AND MIN. PENETRATION WATERWARD OF MEAN HIGH WATER FOR RAMP IS 10' OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY 2" X 6" P.T. DECKING WILL BE ATTACHED WITH #10 SS DECK SCREW X 3" 2" X 2" PICKETS NOT ALL SHOWN FOR CLARITY - PICKETS LANDWARD OF MEAN HIGH WATER AS SHOWN ON SHEET 9 — REMAINDER OF RAMP NOT REQUIRED TO HAVE GUARDS RAMP DETAIL Paul Welch, Inc. Environmental 1984 SW Biltmore Street, # Inc.Michael Mathias Port St. Lucie, FL 34984 ServicesIQS, 17107 S. Indian River Drive �U� O� 1901 Sw Yellowtail Avenue 3 Port Saint Lucie, FL 34953 Fort Pierce, Florida PCN# 3412-414-0001-000-2 Paul Welch, PE No. 29945 14 Phone:772-215-3997 Fax:772-879-4520 www.disenvironmentalservices.com SCALE: AS NOTED JUNE 2021 1 SHEET 3 of 6 2" X 6" P 2" X 6" P. 2" X 6" P.T. BC (2) 5/8' (TYP) 2" X 8" P.T. CROE 2" X 8" P.T. STRIN 2" X 8" P.T. DECKING —'NOTES- - ALL HARDWARE ON THE DECK AND BELOW TO BE GRADE 304 (OR BETTER) SS - ALL 8"0 MARINE DOCK PILES - 6' MIN. PENETRATION INTO FIRM SOIL OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY - 2" X 8" P.T. DECKING WILL BE ATTACHED WITH #10 SS DECK SCREW X 3" - 2" X 2" PICKETS TO BE INSTALLED IN ALL LOCATIONS GREATER THAN 30" ABOVE GRADE 30-FOOT RAMP Environmental CROSS SECTION VIEW DETAIL Services, Inc. Michael Mathias 1901 SW Yellowtail Avenue 7107 S. Indian River Drive Port Saint Lucie, FL 34953 Fort Pierce, Florida PCN# 3412-414-0001-000-2 Phone:772-215-3997 Fax:772-879-4520 www.disenvironmentalservices.com SCALE: 1"=3' s,l i - CAE 3�,I �E COP` 0' 1.5' 3' GRAPHIC SCALE Paul Welch, Inc. 1984 SW Biltmore Street, # 14 Port St. Lucie, FL 34984 UN30.2i 1 Paul Welch, PE No. 29945 JUNE 2021 1 SHEET 4 of 6 �a� 2"X6"1 2" X 6" F 2" X 6" P.T. B( 2" X 8" P.T. CRO 2" X 8" P.T. STRIP 2" X 8" P.T. DECKING 2" X 8" P.T. CROSS BRACE ALL PILINGS 8' ABOVE MI V ABOVE GRADE IN UPI (2) 5/8" (TYP) PER CROS; REVi Vl ED FU,�; =SZ. U MPLEANCE. LUCE COUNTY BOCC -IL..E COPY 0' 1.5' 3' ***NOTES*** GRAPHIC SCALE ALL HARDWARE ON THE DECKAND BELOW TO BE GRADE 304 (OR BETTER) SS ALL 8"0 MARINE DOCK PILES - 6' MIN. PENETRATION INTO FIRM SOIL OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY 2" X 8" P.T. DECKING WILL BE ATTACHED WITH #10 SS DECK SCREW X 3" -2 " 2" X 2" PICKETS TO BE INSTALLED IN ALL LOCATIONS LANDWARD OF MEAN HIGH WATER AND GREATER THAN 30" ABOVE GRADE 90-FOOT RAMP Paul Welch, Inc. Environmental CROSS SECTION VIEW DETAIL 1984 SW Biltmore Street, A14 Services.,chael Mathias Port St. Lucie, FL 34984 7901 SW Yellowtail AvenuueeInc.1T 11C. 7107 S. Indian River Drive Port Saint Lucie, FL 34953 Fort Pierce, Florida � UN 3 0 2021 PCN# 3412-414-0001-000-2 Paul Welch, PE No. 29945 Phone:772-215-3997 Fax:772-879.4520 www.dlsenvironmentalservices.com SCALE: 1" = 3' JUNE 2021 SHEET 5 of 6 Its] 63' --- PF-'-=31====yt====13===Yr SUBSTRATE RAMP SECTION WATERWARD OF MEAN HIGH WATER - PICKETS OPTIONAL (SEE DETAILS ON SHEET 2) RAMP LANDWARD OF MEAN HIGH WATER WITH PICKETS (SEE DETAILS ON SHEET 2) "'NOTES"" ALL HARDWARE ON THE DECK AND BELOW TO BE GRADE 304 (OR BETTER) SS ALL 8"0 MARINE DOCK PILES - MIN. PENETRATION VARIES (6' IN UPLAND BANK AND 10' FOR RAMP AREA INTO RIVER BOTTOM OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY - 2" X 8" P.T. DECKING WILL BE ATTACHED WITH #10 SS DECK SCREW X 3" DETAILS ON PICKETS AND HAND RAILS SHOWN ON SHEET 2 PICKETS NOT ALL SHOWN FOR CLARITY PICKET LOCATIONS IDENTIFIED BASED UPON DECK HEIGHT ABOVE GROUND AND LANDWARD OF MEAN HIGH WATER IQS Environmental Services, Inc. 1901 SW Yellowtail Avenue Port Saint Lucie, FL 34953 OVERALL RAMP Michael Mathias 7107 S. Indian River Drive Fort Pierce, Florida PCN# 3412-414-0001-0004 0' 15' 30' GRAPHIC SCALE Paul Welch, Inc. 1984 SW Biltmore Street, #1 Port St. Lucie, FL 34984 JUN302D21 Paul Welch, PE No. 29946 Phone:772-215-3997 Fax:772-879-4520 www.disenvironmentalservices.com SCALE: 1"=30' JUNE 2021 1 SHEET 6 of 6