DESIGN PRESSURE CALCULATION
Property Information Owner:Davidson Address:6233 Alexandria Cir Ft Pierce, Fl 34982 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 53 62 7 30.7 -33.5 2 Int 74 70.5 7 29.8 -32.5 3 Int 37 38 7 32.5 -35.2 4 Int 74 62 7 30.0 -32.8 5 Int 320 90 7 25.8 -28.5 6 Int 92 90 7 28.8 -31.5 7 Int 37 45 7 32.2 -34.9 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1