HomeMy WebLinkAboutAPPROVED Digital LetterArchitectonic Inc
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1
St. Lucie County Building Department
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
August 25, 2021
RE: 333 Notlem Drive, Fort Pierce, FL 34982
To Whom It May Concern:
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed Sliding Glass Door is incompliance with the 2020 Florida Building Code, 165 mph wind
zone, exposure “C”, risk category II.
Exposure “C” Multiplier for 15’ mean roof height is 1.21
Wind Zone 4 30.5 x 1.21= 36.9
Wind Zone 5 36.7 x 1.21 = 44.5
Required Design Pressures: +/-44.5
Product Design Pressure: -50
Product: Window Craftsman, Inc., Model SS-300 Single Slider, FL# 15963.5
Respectfully Submitted,
_________________________________
Michael Seal, AIA
AR96898
Architectonic, Inc.