NOTICE OF ACCEPTANCE (NOA)
www.miamidade.aov/economv
GAF
1 Campus Drive
Parsippany, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: VersaShield`e Fire -Resistant Roof Deck Protection and VersaShield® SoIoTM Fire -Resistant
Slip Sheet
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature, If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-1022.26 and consists of pages 1 through 3.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 16-1216.02
Expiration Date: 02/07/22
Approval Date: 02/02/17
Page 1 of 3
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: Fiberglass
SCOPE:
This acceptance is for VersaShield' Fire -Resistant Roof Deck Protection (a.k.a "VersaShield® Underlayment") and
VersaShield' SoIoTM Fire -Resistant Slip Sheet (a.k.a "VersaShield SoIoTM"), as described in this Notice of Acceptance,
for use with approved prepared roof assemblies. Designed to comply with the Florida Building Code and the High
Velocity Hurricane Zone of the Florida Building Code.
PRODUCT DESCRIPTION:
Manufactured b
Applicant
VersaShield' Fire -
Resistant Roof Deck
Protection
Test
Dimensions Specifications
Product
Description
42" x 100' rolls ASTM D 226 Non -Asphaltic fiberglass -based underlayment
Type Il and/or fire barrier.
VersaShield' SoIoTM 72" x 166.7' rolls UL790
Fire -Resistant Slip Sheet 36, x 166.7' rolls
MANUFACTURING LOCATION:
1. Conover, NC
EVIDENCE SUBMITTED:
Test Agency Test Identifier
PRI Construction Materials
Technologies
Underwriters Laboratories Inc.
GAF-270-02-02
GAF-748-02-01
ELK-063-02-01
99NK45831
1 ONK 11990
R19254
08CA37926
08CA49140
Non -Asphaltic fiberglass -based slip sheet and/or
fire barrier.
Test Name/Renort
ASTM D 226
ASTM D 226
TAS 100
UL790
UL790
ASTM D 226
UL790
Date
11/15/10
12/12/16
09/27/01
03/21 /00
05/18/1 1
09/13/01
09/23/09
INSTALLATION:
1. VersaShield' Fire -Resistant Roof Deck Protection or VersaShield® SoIoTM Fire -Resistant Slip Sheet shall be
installed in strict compliance with applicable Building Code.
2. VersaShield° Fire -Resistant Roof Deck Protection or VersaShield' Solo— Fire -Resistant Slip Sheet shall be
installed with a minimum 4-inch head lap in a shingle layer fashion.
3. VersaShield' Fire -Resistant Roof Deck Protection shall be mechanically fastened with approved fasteners in
compliance with Florida Building Code 1518.2 when used in lieu of a code prescribed ASTM D 226 Type lI
underlayment.
NOA No.: 16-1216.02
Expiration Date: 02/07/22
Approval Date: 02/02/17
Page 2 of 3
LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire
ratings of this product
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. VersaShield® Fire -Resistant Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30
days of application. VersaShield® Solo- Fire -Resistant Slip Sheet shall not be left exposed to the weather.
4. VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® SoloTm Fire -Resistant Slip Sheet are a
component used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance.
5. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® Solow Fire -Resistant Slip Sheet may be used
with any approved roof covering Notice of Acceptance listing. VersaShield® Fire -Resistant Roof Deck Protection
or VersaShield Solo-i Fire -Resistant Slip Sheet may be used as a component part of an assembly in the Notice of
Acceptance. If VersaShield Fire -Resistant Roof Deck Protection or VersaShield SoloTm Fire -Resistant Slip Sheet
is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product
Control Department for approval provided that appropriate documentation is provided to detail compatibility of the
products, wind uplift resistance, and fire testing results.
6. VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® SoloTM Fire -Resistant Slip Sheet are a non -
asphaltic underlayment that may be used as a fire barrier for prepared roof assemblies. For fire classification of
specific roof assemblies using VersaShield° Fire -Resistant Roof Deck Protection or VersaShield® SoloTm Fire -
Resistant Slip Sheet refer to a current Approved Roofing Materials Directory for fire ratings of this product.
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and
state of manufacturing facility, yellow line to identify the ASTM Standard designation or logo, and the following
statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as
shown below.
MIAMI•DADE COUNTY
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by Building Official or Applicable building code in order to properly evaluate the
installation of this material.
END OF THIS ACCEPTANCE
NOA No.: 16-1216.02
Expiration Date: 02/07/22
Approval Date: 02/02/17
Page 3 of 3