NOTICE OF ACCEPTANCE (NOA)
www.miamidade.eov/economy
Coastal Metal Roofing Sales, LLC
10877 NW 33 Street
Doral, FL. 33172
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In
Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Coastal ML150 24Ga. Steel Panel over Plywood deck
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 21-0422.02
Expiration Date: 06/17/26
Approval Date: 06/17/21
Page 1 of 6
ROOFING SYSTEM APPROVAL:
Category
Sub -Category:
Material:
Deck Type:
Maximum Desien Pressure
Roofing
Metal, Panels (Non -Structural)
Steel
Wood
—176.00 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product
Dimensions
Coastal ML150 24Ga. Length: various
Steel Panel Height: 1-1/2"
Width: 16"
Thickness 24 ga
Min. Yield Strength: 62.6 ksi.
Fixed Clip Length:2"
Height: 1-5/8"
Width: 1-1/4"
Thickness: 24ga
EVIDENCE SUBMITTED:
Test Agency
Intertek
PRI Construction Materials
Technologies
Test
Specifications
TAS 110
Test Identifier
L2072.07-450-18 RO
L2072-01-450-18 RO
L2072.02-450-18 RO
1272T0005
1272T0002
Product
Description
Corrosion resistant, galvanized steel or
galvalume standing seam metal panel.
One piece panel clip used for the field
conditions of DMC 150 SS panel assembly
System B.
Test Name/Report
Date
ASTM E 2140
03/31/21
TAS 125
03/16/21
TAS 100
03/16/21
ASTM G 155 09/24/19
ASTM B It 7 09/11/19
NOA No.: 21-0422.02
Expiration Date: 06/17/26
Approval Date: 06/17/21
Page 2 of 6
APPROVED ASSEMBLIES:
System A: Coastal ML 150 24Ga. Steel Panel 16" wide Panel
Deck Type: Wood, Non -insulated
Deck Description: New Construction 19/32" or greater plywood or wood plank.
Slope Range: l" : 12" or greater (see note below)
Maximum Uplift See Maximum Design Pressures below
Pressure:
Deck Attachment:
In accordance with applicable Building Code, but in no case shall it be less than 8d annular
ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum
"/32") The above attachment method must be in addition to existing attachment.
Underlayment:
Minimum underlayment shall be an ASTM D 226 Type Il installed with a minimum 4" side -
lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12
gauge 1 ""/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12"
o.c. in the field of the roll or any approved underlayment having a current NOA.
Fire Barrier Board:
Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys:
Valley construction shall be in compliance with Roofing Application Standard RAS 133 and
with the current published installation instructions and details in Coastal Metal Sales Roofing,
LLC.'s Installation Manual.
Metal Panels and
Install the "Coastal ML150 24Ga. Steel Panel 16" wide Panel" including flashing
Accessories:
penetrations, valleys, end laps and accessories in compliance "Coastal Metal Sales Roofing,
LLC.'s" Current, published installation instructions and in compliance with the minimum
requirements detailed in Roofing Application Standard RAS 133.
Panels shall be secured along the male rib with approved clips fastened with two corrosion
resistant #10 pancake head fasteners of sufficient length to penetrate through the sheathing a
minimum of 3/16'. The panel clips shall be located at the maximum spacing listed in Table
A below.
Note: For slopes of 1" : 12" up to but not including 2" : 12", a continuous bead of a
Miami Dade Approved Sealant must be applied along the entire Male rib before
attaching the adjacent panel.
For slopes of 2" : 12" and greater, the sealant is not required.
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Corner'
Maximum Design Pressures
46 psf.
—176 psf.
Maximum Clip Spacing
24" o.c.
6" o.c.
Mechanical Seam
900
900
1. Extrapolation shall not be allowed
NOA No.: 21-0422.02
Expiration Date: 06/17/26
Approval Date: 06/17/21
Page 3 of 6
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and corners).
3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 133
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city and state, and the following
statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal
as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model.
MIAMI•DADE COUNTY
�rj...•
ymi
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 21-0422.02
Expiration Date; 06/17/26
Approval Date: 06/17/21
Page 4 of 6
PROFILE DRAWINGS
16" COVERAGE
COASTAL ML150 24GA. STEEL PANEL
NOA No.: 21-0422.02
Expiration Date: 06/17/26
Approval Date: 06/17/21
Page 5 of 6
0-4375
0.313
i.825
j�-0.913�
ALL DIMENSIONS ARE
DECIMAL INCHES
TOLERANCE: 0.030t
2.00D--{
FIXED CLIP
END OF THIS ACCEPTANCE
NOA No.: 21-0422.02
M64MMADE COUNTY Expiration Date: 06/17/26
Im Approval Date: 06/17/21
Page 6 of 6