HomeMy WebLinkAboutAPPROVED product approvalFL 38763.02 10877 NW 33RD ST I DORAL, FL 33172 .,$ 786.-349-4009 rr Mechanical standing seam panel with 16" maximum coverage and a nominal rib height of 1.5" y' 24ga (min) steel Corrosion resistant per FBC 1507.4.3 where required CAStC— ler,. jll�� #10 x 1-inch pancake style fastener, 2 per clip Compliant with FBC 1506.6 where required. Substrate/Deco, Ws I • 111RWA ••• 1 • • I. 11111111 I N IC • t Wa MethocLA: 901 seam & (2) #10 x 1" fasteners per clip with clips at 24" o_c_- 96 PSF Method B: 90' seam & (2) #10 x 1" fasteners per clip with clips at 6" o_c_: 176 PSF Pr nc�' 7 A factor of safety of 2 has been applied. METHOD A 90" SEAM «� CLIP WITH 2" BASE @ 24" O.C. 1l � (2) 00 FASTENERS PER CLIP 24ga. 2" long fixed clip METHOD B 90" SEAM CLIP WITH 2" BASE @ 6' D.C. '-- (2) 910 FASTENERS PER CLIP David Eng, PE j Timberlake Cove, LLC 1 1317 Edgewater Dr Ste 2339 Orlando FL FL PE 81377 1 FL CA 33344 1 , % 11 , Digitally $igned by Dawd E Eng u� Contaes Into, d vid.eiig9timberlakeceve.00m Date: 2021,06.02 14:49:46-04'00' This item has been digitally signed and sealed by D.E. Eng, PE, on the date indicated. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies 04'•��cEtus� • �'G' ' IVo.81377 0 STATE OF �411� /ONAI- ��.�`. ��/fllll111 0\ Underlayment: Comply with local building code or FBC 1507.1.1/1518.2 where required. Slope: Comply with local building code or FBC 1507.4.2/FBC 1515.2 where required. Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511/1521, provided the existing roof meets the conditions required by the applicable code. Fire Barrier: Comply with FBC 1516.1 and 1516.2 where required. Technical Documentation: This product has been tested to the following standards by Intertek Testing (TST 1527): • TAS 125-03 & UL580/UL1897: report L2072.01-450-18 RO • TAS 100-95: report L2072.02-450-18 RO Compliance Statement: This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2 (non-E VEW and 1518.9.1/1523.6.5.2.4 (HVHZ), as required by FL Rule 61G20-3, method 1D; subject to the exclusions/limitations noted below. Design Process: The load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use of these tables assumes that the structure is: • Enclosed and conforms to wind-borne debris provisions and is a regular shaped building • Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers for project specific approval by local authorities having jurisdiction. Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will they acquire a financial interest in any company manufacturing or distributing products under this evaluation. The some entities do not have, nor will they acquire, a financial interest in any other entity involved in the approval or testing process of the product. Exclusions and Limitations: Design of deck and roof structure (to include deck attachment) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated weathering/salt spray is outside the scope of this evaluation. Static water leakage is outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based on this evaluation report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding performance of this product. CO.®STiSL 2 MET®L METHOD A METHOD B 80' SEAM 90' SEAM CLIP WITH 2' BASE ® 11 CLIP WITH 2' BASE (� " O.C. 6'O.C. (2) #10 FASTENERS (2) #10 FASTENERS PER CLIP PER CLIP OPTIONAL ENGINEERING LOAD TABLES Instructions: Select the appropriate load table that applies to the structure in question. Determine the design wind speed for the project location. Use the attachment method indicated for that windspeed within each roof zone. NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. For the load tables below, the worst case was taken for each zone and reported using the standard zones 1-2-3: Zone 1 includes zones 1 and 1' Zone 2 includes zones 2e, 2r, and 2n Zone 3 includes zones 3e and 3r Combining these zones creates a clear, simple scheme, at the expense of some design efficiency. Contact the manufacturer for further information, or consult a licensed design professional. Application: There are conservative assumptions used in combining scenarios for these load tables for cases when the required design load is unknown. The maximum allowable loads for this product are shown on page 1 of this approval. If the required allowable design loads are known, and the required design loads are less than the allowable load of the product, then the product is sufficient for use, andthesg load tables can be Ignored_ If the required design loads are NOT known, then the appropriate load table here may be used. --a \2 \ \ 2 2 3 a 2 2 3 P 1 1 21 �. ---- — ---- ., a 3 _ _� 3 _ a a 4 HIP ROOF GABLE ROOF a •'. �0%Oi L@AST NW.T. GMEN51b, O OM, WlIIGIPYC,1,9 SM 6.,BVT NOt LE89TXAN EITHER 940i LEPST NOR20NfAL04EHW. q VT IOW 0R49 G:TETiMW W By pESIGH ON OTXEP PPR,LRBI.E C(bE ROOF ZONES FOR GENERIC BUILDING Use this load table for structures which meet the following criteria: Are located in Exposure B area Have either a flat roof, or gable/hip roof with max slope of 45° Have a mean Roof Height of 30 feet or less FL38763.02: 24na 15OMS on 15/32" plywood 105 110 120 130 140 150 160 170 180 190 200 A A A A A A A A Fne A A A A A A A A A A A B B B A A A A A A '" B B B B Use this load table for structures which meet the following criteria: Are located in Exposure B area Have either a flat roof less than 7', hip roof with max slope of 45", or gable roof with slope between 200 and 450 Have a mean Roof Height of 30 feet or less FL38763.02: 24aa 15OMS on 15132" plywood Wind 105 110 120 130 140 150 160 170 180 190 200 Zonal: A A A A A A A A A A A Zone 2: A A A A A A A A A B B Zone 3: A A A A A A A B B B B Use this load table for structures which meet the following criteria Are located in B, C, or D exposure area Have either a flat roof, or gable/hip roof with max slope of 460 Have a mean Roof Height of 30 feet or less FL38763.02: 24aa 15OMS on 15/32" plywood Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A B B B B Zone 2: A A A A B B B B BB Zone 3: A A A B B B B B Use this load table for structures which meet the following criteria: Are located in B, C, or D exposure area Have either a flat roof less than 70, hip roof with max slope of 450, or gable roof with slope between 200 and 45° Have a mean Roof Height of 30 feet or less FL38763.02: 24aa 150MS on 15/32" plywood Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A B B 8 B Zone 2: A A A A A B B B B B B Zone 3: A A A B B B B 8 B r /�ST/�L 3 MET/&L