Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
sand underlay c
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications ' Contact us BCIS Site Map# 1 Links i Search Wda Product Approval USER: Public User # �y Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL2569-R22 w_ Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Soprema, Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville, NON -US 00000 (819) 478-2400 memathieu@soprema.ca Authorized Signature Marc -Etienne Mathieu memathieu@soprema.ca Technical Representative Marc -Etienne Mathieu Address/Phone/Email 1688 Jean-Berchmans-Michaud Drummondville, NON -US 00000 (819)478-2400 Ext3327 memathieu@soprema.ca Quality Assurance Representative Jean -Francois Cote, Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888)811-3145 jfcote@soprema.ca Category Roofing Subcategory Underiayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert J. M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/21/2023 Validated By John W. Knezevich, PE Certificate of Independence Referenced Standard and Year (of Standard) Validation Checklist - Hardcopy Received FL2569 R22 COI 2021 01 COI NIEMINEN pdf Standard Year ASTM D1970 2015 ASTM D4601 2012 ASTM D4798 2011 FM 4474 2011 FRSA/TRI Sixth Edition 2018 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised mary of Products Method 1 Option D 04/19/2021 04/19/2021 04/26/2021 06/08/2021 07/29/2021 FL # Model, Number or Name ; Description A 2569.1 Soprema Roof Underlayments for ,`' Self adhering roof underlayments f use in FBC HVHZ jurisdictions Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER Section 5 for Limits of Use. Installation Instructions FL2569 R22 II 2021 04 19 FINAL ER SOPREMA HVHZ FL2569- R22.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL2569 R22 AE 2021 04 19 FINAL ER SOPREMA HVHZ FL2569- R22.pdf Created by Independent Third Party: Yes 2569.2 Soprema Roof Underlayments for I Self adhering roof underlayments I use in FBC non-HVHZ jurisdictions Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-150 Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The design pressure noted herein pertains to underlayment systems used beneath adhesive -set tile systems. Refer to ER Section 5.8.3 for details. Installation Instructions FL2569 R22 II 2021 04 19 FINAL ER SOPREMA NON- HVHZ FL2569-R22 pdf Verified By: Robert Nieminen, P.E. PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL2569 R22 AE 2021 04 19 FINAL ER SOPREMA NON- HVHZ FL2569-R22.pdf Created by Independent Third Party: Yes ' W Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Virzi M FEF a Credit Sate security ii_,nUCS` n tNGINEER EVALUATE SOPREMA, Inc. 1640 rue Haggerty Drummondville, Quebec J2C 5138 Canada (819) 478-2400 TEST MEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 00g1 ')r,')_G')A r CONSULT Evaluation Report 3m-S0PC-2I-FBCER.A FL259-R22 (HVHZ) Date of Issuance: 04/19/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code, High Velocity Hurricane Zone sections noted herein. DESCRIPTION: SOPREMA Roof Underlayments for use in FBC HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOI etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: l��15�l1:ITft FFJ.,s �: ♦; r r Robert J.M. Nieminen, P.E. ` r Florida Registration No. 59156, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/19/2021. This does not serve as an electronically signed d CERTIFICATION OF INDEPENDENCE: ocument. 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC ROOFING COMPONENT EVALUATION: 4.1 4.2 4.3 4.4 INNEMOletc. Product Category: Roofing Sub -Category: Underlayment Compliance Statement: SOPREMA Roof Underlayments, as produced by SOPREMA, Inc., have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code, High Velocity Hurricane Zone through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Proyerty Standard Year TAS 110 Material standard ASTM D1970 2015 TAS 110 Material standard ASTM D4601 2012 TAS 110 TAS 110 Material standard TA5 103 2020 REFERENCES: Accelerated Weathering ASTM D4798 2011 - Entity Examination Reference Date ERD (TST6049) ERD (TST6049) TAS 103 (MS) ASTM S43530.02.14-1-R1 02/21/2014 ERD (TST6049) D1970 (QC) ASTM D1970 (OH) S44870.04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (MS) S44870.04.14-1 S44870.04.14-4 04/10/2014 ERD (TST6049) ASTM D1970 (OH) 540540.10.14 04/10/2014 10/31/2014 ERD TST6049 (TST6049) ERD (TST6049) Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015 NEMO (TST6049) ASTM D4798 ASTM D1970 / TAS 110 (QC) SOPC-SC8520.04.14 04/27/2015 NEMO (TST6049) Tile Slippage SOPC-SC8970.08.15-RI 04/25/2018 NEMO (TST6049) ASTM D4601 (MS) 4S-SOPC-18-002.09.18 09/21/2018 NEMO (TST6049) ASTM D4601 (OH) 4q-SOP-I9-SSMBB-01.A 4q-SOP-I9-SSMBB-01.B 03/11/2019 03/11/2019 NEMO (TST6049) NEMO (TST6049) ASTM D4798/D1970 (OH & MS) 4S-SOPC-18-002.05.19.A 05/31/2019 NEMO (TST6049) Tensile Adhesion / Long Term Aging Peel 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020 NEMO (TST6049) adhesion (existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020 NEMO (TST6049) Peel adhesion (existing underlayments) ASTM D1970 (MS) 4j-SOPC-20-SSUDL-01.A 01/07/2021 PRI(TST5878) ASTM D1970 (MS) 4j-SOPC-2I-SSUDL-01.A 04/19/2021 Soprema, Inc. (PDM3511) Equivalency Declaration SOP-064-02-01 SA SMOOTH PLY 40 12/03/2013 UL, LLC (QUA9625) (Q ) Quality Control MLA File No. R16814 06/29/2015 12/10/2015 UL, LLC (QUA9625) UL, LLC (QUA9625) Quality Control Quality Control MLA File No. R27605 05/08/2019 UL, LLC (QUA9625) Quality Control Service Confirmation Florida BCIS 06/29/2020 Current PRODUCT t*kRIPTION. Product LASTOBOND TU HT Tri-Built S/A HT TU Underlayment LASTOBOND Shield Material Standard ASTM D1970 and TAS 103 ASTM D1970 and TAS 103 ASTM D1970 Plants) Gulfport, MS Gulfport, MS Drummondville, QC Description self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch RESI5T0 SA SMOOTH PLY 40 ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment NEMO ETC, LLC. Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION SOPREMA Roof Underlayments Evaluation Report 3m-SOPC-2I-FBCER.A F1.2569-1122 (HVHZ) Revision 0: 04/19/2021 Page 2 of 7 4,5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 4.17 4.18 i Product Material Standard Plant(s) Description LASTOBOND Shield HT ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high LASTOBOND Pro HT-N ASTM D1970 Drummondville, QC temperature, SBS modified bitumen roof underlayment self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch LASTOBOND Pro HT-S ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high EnviroShield temperature, SBS modified bitumen roof underlayment ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high LASTOBOND Eco ASTM D1970 Drummondville, QC temperature, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH LASTOBOND Smooth Seal HT ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Tri-Built Smooth HT S/A Wadsworth, OH modified bitumen roof underlayment drlayment UFRESISTO ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS Source Grip -Rite Wadsworth, OH modified bitumen roof underlayment h Seal HT ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, SBS L81236 Wadsworth, OH modified bitumen roof underlayment ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH TRI-BUILT Sand-R SA Shingle Underlayment ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH PrimeSource Grip -Rite Eave & Valley Protector ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH SRS TopShield ICE & WATER DEFENDER ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, SBS Gulfport, MS modified bitumen roof underlayment Wadsworth, OH self -adhering, glass -mat reinforced, sand -surfaced, SBS RESISTO l61244 ASTM D1970 Drummondville, QC Gulfport, MS modified bitumen roof underlayment Wadsworth, OH MODIFIED SOPRA-G ASTM D4601, Type 11 Gulfport, MS Fiberglass reinforced, SBS modified asphaltic base sheet Wadsworth, OH 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC Non -High Velocity Hurricane Zone jurisdictions (i.e., outside of Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. NEIVIO ETC, LLC. Certificate of Authorization ##32455 7T" EDITION (2020) FBC HVHZ EVALUATION SOPREMA Roof Underlayments Evaluation Report 3m-SOPC-2I-F8CER.A FL2569-R22 (HVHZ) Revision 0: 04/19/2021 Page 3 of 7 ONEMOjetc. 5.5 SOPREMA Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FBC Sections TAS 110($10), RAS 115 TAS 110fS11J, RAS 118,119 & 120 RAS 133 TAS 110($11) RA5130 Underlayment Asphalt Shingles Clay and Concrete Tile Metal Slate or Slate- Type Shingles Wood Mechanical Attach Adhesive- Set LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment Yes Yes Yes See 5.6.1 Yes Yes Yes LASTOBOND Shield, Pro HT-N, RESISTO SA SMOOTH PLY 40 Yes No No Yes Yes Yes LASTOBOND Shield HT, Pro HT-S Yes No No Yes Yes Yes EnviroShield Yes No No Yes Yes Yes LASTOBOND ECO, RESISTO LB1236, TRI- BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244 Yes No No No Yes Yes LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip -Rite Smooth Seal HT Yes No No Yes Yes Yes 5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations. TABLE 1A: ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS' Underlayment Adhesive Florida Product Approval LASTOBOND TU HT, Tri-Built S/A HT TU Dupont "Tile Bond— Roof Tile Adhesive" FL22525 Underlayment ICP Adhesives and Sealants "Polyset® AH-160" NOA 20-1124.07 5.7 Allowable Substrates: 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC. Certificate of Authorization #32455 rH Evaluation Report 3m-SOPC-2I-FBCER.A 7 EDITION (2020) FBC HVHZ EVALUATION FL2569-1122 (HVHZ) SOPREMA Roof Underlayments Revision 0: 04/19/2021 Page 4 of 7 IM TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Substrates (designed to meet wind loads for project) L_ Type Primer Material(s) LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, RESISTO LB1236, TRI-BUILT self- Existing Existing sand -surfaced, glass -fiber Sand-R SA Shingle Underlayment, Grip -Rite adhering substrate RESISTO EXTERIOR PRIMER surfaced, mineral -surfaced or Eave & Valley Protector or TopShield ICE & WATER DEFENDER film -surfaced roof underlayment* *Final acceptance of onv existinn v,hctrnte in o, o r.,, question arise as to the suitability of an existing subs ` trate to receive LASTOBOND TU HT,Tri'installer Built S/A HT TUUnderl aymentthe A hRESISTO LB1236,Jurisdiction.ority Having RI -BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 5.8 Attachment Limitations: Refer to Section 6 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Maximum LASTOBOND Eco, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Installation Type Exposure (days) Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244 Mechanically attached 30 LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT Mechanically attached 90 LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment Mechanically attached or adhesive -set tile roof system 180 D.1u I ne �,nppage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can onlv be exrearinrl h" ucina k�++_ A„v:�� v --"—"_ "`^•••b 'va...,, is v ll 1C IUUI UIeS. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 10-tile stack Lugged 6:12 Max. 10-tile stack 5:12 Double -tile stacking method, as shown below 6:12 LASTOBOND TU HT,Tri- Built S/A HT TU Underlayment Lugged NEMO ETC, I.I.C. Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Evaluation Report 3m-SOPC-2I-FBCER.A SOPREMA Roof Underlayments F1.2569-1122 (HVHZ) Revision 0: 04/19/2021 Page 5 of 7 U(4 ® I etc. 6.1 SOPREMA Roof Underlayments shall be installed in accordance with SOPREMA published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if aoglicable)_ 6.3 6.3.1 6.3.2 6.3.3 Approved Assemblies: Deck Type 1: Wood, Non -Insulated Deck Description: Min 19/27" nl---A System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5). Surfacing: FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for allowable tile adhesives and Table 4 for tile stagging limitations. Deck Type 1: Wood, Non -Insulated Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT, self - adhering. Surfacing: FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate -type shingles, wood shakes or wood shingles. Deck Type 1: Wood, Non -Insulated Deck Description: Min. 19/32" plywood or wood plank System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c. in a staggered grid -pattern between the overlaps. Cap Ply: LASTOBOND ECO, RESISTO LB1236, TRI-BUILTSand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244, self -adhering. Surfacing: FBC HVHZ Approved asphalt shingles, slate, slate -type shingles, wood shakes or wood shingles. NEMO ETC, I.I.C. Certificate of Authorization #32455 7r" EDITION (2020) FBC HVHZ EVALUATION Evaluation Report 3m-SOPC-2I-FBCER.A FL2569-R22 (HVHZ) SOPREMA Roof Underlayments Revision 0: 04/19/2021 Page 6 of 7 I �zz" NEMO etc. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL LLC—QUA9625; (414) 248-6409; Ka_ren.buchmann ul com - END OF EVALUATION REPORT - NEMO ETC, I.I.C. Certificate of Authorization #32455 7T"EDITION (2020) FBC HVHZ EVALUATION Evaluation Report 3m-SOPC-2I-FBCER.A SOPREMA Roof Underlayments Revision s09-R22 (HVHZ) Revision 0: 04j19/2021 Page 7 of 7