AIR LOAD CALCULATIONS
9/15/21, 12:40 PM Customer (1059x1512) Elite Electric & Air Load Calculation 16,91 SW South Macedo Blvd Port St. Lucie F/ 34984 CAC1816433 EC13006036 772-340-3797 Customer Name Nancy Hyde Address 2520 Lvcy Lane Existing Service Feeder 210 THHN Existing Panel Size: 200 AMP Main Breaker Size, 200 Amp Number of Breakers: 40 Existing loads amps X volts HOME watts watts Lighting (not including garage, porches, 884 sq ft 3 2652 Appliances 2 qty 1500 3000 Laundry I qty 1500 I500 Range I qty 8000 8000 Dishwasher 1 qty 1500 1500 Garbage disposal I qty 1500 1500 Microwave 1 qty 2000 2000 Water heater I qty 4500 4500 Clothes Dryer I qty 5000 5000 Refrigerator 1 qty 1500 1500 Bathroom 1 1 qty 1500 150Q Sprinkler Pump 1 qty 2000 2000 Sewer pump I qty 2000 2000 Pool heater 0 qty 12000 0 Boat lifts 0 qty 0 Boat dock pedestal 0 qty 0 Other loads 0 qty 0 Existing loads sub -total New Loads RV outlet 1 qty 3600 3600 additional loads 0 qty 0 additional loads 0 qty 0 additional loads 0 qty additional loads 0 qty 0 additional loads 0 qty 0 additional loads 0 qty 9 New, loads sub -total Subtotal General Load 402S2 First 10kvo @ 100% 10000 Remainder of general load @ 40% 121,00;8 A/C -1 @ 100% of nameplate rating 0 qty 0 A/C -2 @ 100% of nameplate rating 0 qty 0 A/C-3 @ 100% of nameplate rating 0 qty 9 Heat-1 @ 65% 1 qty 10000 6500 Heat-2 @ 55% 0 qty 0 Heat-3 @ 65% 0 qty —0 Total Net General Load 28600.8 Total Amps (Total va 1240) 119 Areas in, grey are not to be edited 36652 RM https://go.servicetitan.com/Attach/Customer?name=Attaches%2F2al IcKb-5cl 2-4dbc-ge4l-f4lebbab7e7l—cdv—photo-000-dm35z7o6ivw.jpg 1/1