Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GENERATOR LOAD CALCULATIONS
alm Beaches generator rrr • West Palm Beachz•' i i THE STANDBY POWER PEOPLE gen era erato rsu•-rcenter.co Generator Load Calcultion Utilizing the Optional Method (NEC Article 220 Part IV) Customer: Ronald Ruotolo Sales Associate: Daniel Luce Address: 1409 NW Lancewood Terrace Date Prepared: 6/3/2021 rELTYPE HEAT TYPE ATS Size ATS Qty ATS Size ATS Qty Palm City,FL 34990 LP Electric 200A 1 Choose Choose Single Phase Residential Loads Only AMPS QTY VA Gen Load Mgmt. Load Shed A/C vs.Heat Living square feet 2,736 3 8,208 0 0 A/C Equipment I A/C 1 A/C 2 A/C 3 A/C 4 I A/C 5 A/C 6 A/C 7 Small Appliance Circuits(2 req.) 3 1,500 4,500 0 0 Amps 17.76 14.25 0 0 0 0 0 120v Laundry Circuit(1 req.) 1 1,500 1,500 0 0 CU Tonage Choose CU Choose CU Choose CU Choose CU Choose CU Choose CU Choose CU Dishwasher 1 1,000 1,000 0 0 Total VA 5462.4 4420 0 0 0 0 0 Disposal 1 1 1,100 1,1001 0 0 Brkr Size 60a/2p 30a/2p Breaker Breaker Breaker Breaker Breaker Refrigerator 1 1,500 1,500 0 0 AHU Heat kw Choose KW Choose KW Choose KW Choose KW Choose KW Choose KW Choose KW Electric Dryer 1 5,000 5,000 0 0 1 Total VA 1 11600 58001 01 01 0 0 0 Electric Range 1 8,000 8,000 0 0 A/C vs.Heat I Total VA 11600 5800 01 01 0 0 0 Microwave 1.8 kW 1 1,800 1,800 0 0 Load Management 1 2 0 1 0 1 0 0 0 Range Hood Fan(std.) 1 300 300 0 0 A/C vs.Heat VAw/LMD's 01 0 01 01 01 01 0 No Additional Cooking Equipment 1 0 0 0 0 0 Additional Equipment and/or Sub-Panel Loads Electric Tank HWH 1 4,500 4,500 0 0 Equipment/Panel Type AMPS QTY VA Gen load Mgmt. Load Shed No Additional Water Heaters 0 0 0 0 0 Choose Panel and/or Equipment 0 0 0 0 0 No Additional Water Heaters 0 0 0 0 0 Choose Panel and/or Equipment 0 0 0 0 0 Circulating Pump#1 1 1,656 1,656 0 0 Choose Panel and/or Equipment 0 0 0 0 0 Pool Light 1 300 3001 0 0 Choose Panel and/or Equipment 0 0 0 0 0 Gas Pool Heater#1 1 340 340 0 0 Choose Panel and/or Equipment 0 0 0 0 0 Garage Door Opener 3/4 h.p. 1 600 600 0 0 Choose Panel and/or Equipment 0 0 0 0 0 Garage Door Opener 1/2 h.p. 1 540 540 0 0 Choose Panel and/or Equipment 0 0 0 0 0 Mini Split A/C Ig. 1 1,650 1,650 0 1 0 Choose Panel and/or Equipment 0 1 0 0 0 1 0 No Additional Equipment 0 0 0 0 0 Choose Panel and/or Equipment 0 0 0 0 0 No Additional Equipment 0 0 0 0 0 Choose Panel and/or Equipment 0 0 0 0 0 No Additional Equipment 0 0 0 0 0 0 0 0 0 0 0 Golf Cart Charger 20a/1p 1 1,560 1,560 0 0 0 0 0 0 0 0 0.01 0 0 01 0 0 0 0 0 0 0 0 0.0 0 0 0 0 0 0 0 0 0 0 0 0.01 0 1 0 0 0 1 0 1 01 0 1 01 01 0 0 Optional Feeder Total load incl.Add.Equip and/or Sub Panel(s) 44,054 Gen.shed Total VA for Additional Equipment and/or Sub Panel Loads 1 01 0 0 and Service Load First 10kva @ 100% 10,000 0 Calculations Remaining va x 40% 13,622 A/C shed Notes: NEC 220.82(B) Total Derated General Load 23,622 17400 NEC 220.82(C) Total AC vs.Heat VA @ 100% w/LMD's: 0 Total VA Total#of Managed Loads 2 23,6 22 NEC220.82(B)+(C) Total Calculated VA Load Shed 0 Signature: Total Amps Total Calculated Ampere Load 98.4 17,400 Total#of Load Management Devices 2 Roger Hawkins Lic.#EC13010145 Maximum Generator Amps= 100 Recommended Total Managed Load VA 17,400 Date: 6/3/2021 Generator Main Breaker Size= 100 Generator Size 24 kW Total Managed Load load Amps 72.5