HomeMy WebLinkAboutAPPROVED DS94089(1)94089 | 44435-6383796296 | Page 1/2
Date: August 27th, 2021
ASCE 7 Components & Cladding Wall Pressure Calculator
Prepared For:
Wright's Impact Window & Door
176 E Highland Ave
Clermont FL
Project: Drnek, Laura
Project Address:
9400 S Ocean Dr Unit #302B
Jensen Beach Florida
08/27/2021
Box for Engineer Seal Only-Original Rqd for Permit & Use
Frank Bennardo, PE FL46549 or Richard Neet, PE FL86488
The following has been considered in determining allowable stress design (ASD) wall opening pressures for the above-
referenced location.
ASCE: ASCE 7-16 (7TH EDN FLORIDA BUILDING CODE, 2020 FBC,
2018 IBC)
Wind Velocity: 170 MPH
Exposure Category: D
Kd: 0.85
Kzt: 1
Minimum Building Dimension: 50FT
Mean Roof Height: 120FT
Unit Elevation: 30FT
ROOF SLOPE: SLOPED (>=10°)
Number Of Openings: 7
Shutter: NO
Mark: 1
Height Of Opening: 38 IN
Width Of Opening: 36 3/4 IN
Zone: 4
Mark: 2
Height Of Opening: 50 1/4 IN
Width Of Opening: 26 1/2 IN
Zone: 4
Mark: 3
Height Of Opening: 50 1/4 IN
Width Of Opening: 57 3/4 IN
Zone: 4
Mark: 4
Height Of Opening: 50 1/4 IN
Width Of Opening: 57 3/4 IN
Zone: 4
Mark: 5
Height Of Opening: 50 IN
Width Of Opening: 26 1/2 IN
Zone: 4
Mark: 6
Height Of Opening: 38 1/8 IN
Width Of Opening: 36 7/8 IN
Corp. Office: 160 SW 12th Avenue Suite 106, Deerfield Beach, Florida 33442
(954) 354-0660 | (866) 396-9999 Team@EngineeringExpress.com | EngineeringExpress.com
94089 | 44435-6383796296 | Page 2/2
Zone: 4
Mark: 7
Height Of Opening: 38 1/8 IN
Width Of Opening: 36 7/8 IN
Zone: 4
Based on the above, the following ASD design pressures apply for the
opening marks which shall correspond with contractor-supplied building
layout:
a: 5 FT
Mark: 1
Wall Positive Pressure: 49.6PSF
Wall Negative Pressure: -60.3PSF
Mark: 2
Wall Positive Pressure: 49.6PSF
Wall Negative Pressure: -60.3PSF
Mark: 3
Wall Positive Pressure: 49.6PSF
Wall Negative Pressure: -60.3PSF
Mark: 4
Wall Positive Pressure: 49.6PSF
Wall Negative Pressure: -60.3PSF
Mark: 5
Wall Positive Pressure: 49.6PSF
Wall Negative Pressure: -60.3PSF
Mark: 6
Wall Positive Pressure: 49.6PSF
Wall Negative Pressure: -60.3PSF
Mark: 7
Wall Positive Pressure: 49.6PSF
Wall Negative Pressure: -60.3PSF
Design pressure results are in accordance with the Building & ASCE 7 codes listed above for an ENCLOSED structure only
(Gcpi=+-0.18). Results are based on contractor-supplied data and are not field verified by this office. Input shall be verified
by others prior to permit & use. Selection of all components & their respective approvals shall be by others and are to be
within the ASD design pressure limitations stated herein. Results only valid with original or verifiable digital seal by a
licensed PE of this firm. For more information on any of the terms listed herein, or to use a design tool to evaluate your
openings, visit EngineeringExpress.com/Wind.
Powered by TCPDF (www.tcpdf.org)
Corp. Office: 160 SW 12th Avenue Suite 106, Deerfield Beach, Florida 33442
(954) 354-0660 | (866) 396-9999 Team@EngineeringExpress.com | EngineeringExpress.com