HomeMy WebLinkAboutAPPROVED DS94089(1)94089 | 44435-6383796296 | Page 1/2 Date: August 27th, 2021 ASCE 7 Components & Cladding Wall Pressure Calculator Prepared For: Wright's Impact Window & Door 176 E Highland Ave Clermont FL Project: Drnek, Laura Project Address: 9400 S Ocean Dr Unit #302B Jensen Beach Florida 08/27/2021 Box for Engineer Seal Only-Original Rqd for Permit & Use Frank Bennardo, PE FL46549 or Richard Neet, PE FL86488 The following has been considered in determining allowable stress design (ASD) wall opening pressures for the above- referenced location. ASCE: ASCE 7-16 (7TH EDN FLORIDA BUILDING CODE, 2020 FBC, 2018 IBC) Wind Velocity: 170 MPH Exposure Category: D Kd: 0.85 Kzt: 1 Minimum Building Dimension: 50FT Mean Roof Height: 120FT Unit Elevation: 30FT ROOF SLOPE: SLOPED (>=10°) Number Of Openings: 7 Shutter: NO Mark: 1 Height Of Opening: 38 IN Width Of Opening: 36 3/4 IN Zone: 4 Mark: 2 Height Of Opening: 50 1/4 IN Width Of Opening: 26 1/2 IN Zone: 4 Mark: 3 Height Of Opening: 50 1/4 IN Width Of Opening: 57 3/4 IN Zone: 4 Mark: 4 Height Of Opening: 50 1/4 IN Width Of Opening: 57 3/4 IN Zone: 4 Mark: 5 Height Of Opening: 50 IN Width Of Opening: 26 1/2 IN Zone: 4 Mark: 6 Height Of Opening: 38 1/8 IN Width Of Opening: 36 7/8 IN Corp. Office: 160 SW 12th Avenue Suite 106, Deerfield Beach, Florida 33442 (954) 354-0660 | (866) 396-9999 Team@EngineeringExpress.com | EngineeringExpress.com 94089 | 44435-6383796296 | Page 2/2 Zone: 4 Mark: 7 Height Of Opening: 38 1/8 IN Width Of Opening: 36 7/8 IN Zone: 4 Based on the above, the following ASD design pressures apply for the opening marks which shall correspond with contractor-supplied building layout: a: 5 FT Mark: 1 Wall Positive Pressure: 49.6PSF Wall Negative Pressure: -60.3PSF Mark: 2 Wall Positive Pressure: 49.6PSF Wall Negative Pressure: -60.3PSF Mark: 3 Wall Positive Pressure: 49.6PSF Wall Negative Pressure: -60.3PSF Mark: 4 Wall Positive Pressure: 49.6PSF Wall Negative Pressure: -60.3PSF Mark: 5 Wall Positive Pressure: 49.6PSF Wall Negative Pressure: -60.3PSF Mark: 6 Wall Positive Pressure: 49.6PSF Wall Negative Pressure: -60.3PSF Mark: 7 Wall Positive Pressure: 49.6PSF Wall Negative Pressure: -60.3PSF Design pressure results are in accordance with the Building & ASCE 7 codes listed above for an ENCLOSED structure only (Gcpi=+-0.18). Results are based on contractor-supplied data and are not field verified by this office. Input shall be verified by others prior to permit & use. Selection of all components & their respective approvals shall be by others and are to be within the ASD design pressure limitations stated herein. Results only valid with original or verifiable digital seal by a licensed PE of this firm. For more information on any of the terms listed herein, or to use a design tool to evaluate your openings, visit EngineeringExpress.com/Wind. Powered by TCPDF (www.tcpdf.org) Corp. Office: 160 SW 12th Avenue Suite 106, Deerfield Beach, Florida 33442 (954) 354-0660 | (866) 396-9999 Team@EngineeringExpress.com | EngineeringExpress.com