HomeMy WebLinkAboutPOOL SPECIFICATIONS (2)POOL
POOL EQUIPMENT SHALL BE SCREENED
IF REQUIRED BY LOCAL CODE
5 3" f 4' 7"
r— — — — — — —
GFI LOCATION MIN 6 & MAX
OF 20' TO WATERS EDGE
I
I �
I
I
FOOTERFOR
SCREENEWL06URE
18' x 86" SWIMOUT
DECKMOUNTED IN
POOLALARMPER
FBC7THEDICTION
(2020) R4501.17.1.9(3)
io
c•� TABLE WI BENCH
I �
�vv
f
v. _
I
I
I
SF SUNSHELFWI(1) EA BUBBLER
&UMBRELLAHOLDER
WRbrjvj
RESIDENCE
NOTE:
TOP OF POOL ELEVATION IS 6" LOWER THAN
F.F.E. OF HOUSE
DECO DRAIN
NOTE:
POOL CONTRAC rOR TO VERIFY ALL PROPERTY LINE LOCATIONS
AND POOL ELEV4TION PRIOR TO CONSTRUCTION.
POOL LAYOUT AND DIMENSIONS TO BE VERIFIED WI OWNER
PRIOR TO CONS rRUCTION
PAGE 1 DRA4ED BY: G.S.M. SCALE: 1/8" = 1' N
i
UMBRELLA
HOLDER
16'7"
;., .:m
y
i
s 3'
7 _
LED
BUBBLER - f,
4 ALIED
OR .ER
DoOtZ WIN�U
aw
w tit
SEE PIPING SCHEMATIC
FOR DETAILS AND SIZES
PAGE P4
#8 BARE COPPER WIRE FOR
360 DEGREE WITH 4JUMPERS
I TO BE 18"-24'FROM WATERS EDGE
I
I
I
23'3"
•� OVERFLOW
I �61NE
I
I
I o
I A
I
I
I CLEANING LINE WITH
VAC'LOC FITTING SHALL
I BE LOCATED NO GREATER
THAN 12' BELOW WATER
LEVEL APSP 7SEC4.6
18'2"
THOMPSON, DAN
7907 S INDI N RIVER DR
FORT PI=RC , FL 34982
DESIGNER
reed Esneci
!
1
I
I
I
I
i
I
I
1
1
!
I
I
I
I
I
I
SPECIFICATIONS TURNOVER RATE: 2.39 HR
POOL SIZE: 17 X 32' POOL DEPTH: 3' - 5'fi"
POOL 84' VOLUME: (GALLONS) 5,155 POOL AREA SQ. FT. 595
ETER:
PER
POOL & AUXIL IARY POOL EQUIPMENT
POOL PUMP: I JANDY FLO PRO 1.65 HP VSP SPA SIZE: N!A
POOL FILTER: 200 SF CARTRIDGE SPA POOL S.F./ L.F. /GAL N/A
POOL INLETS: 3
SPA JETS: NIA
SPA LIGHT: N/A
SKIMMER:
1
2 —LED NICHELESS
RAISED SPA:
NIA
POOL LIGHT:
POOL HEATER TYPE:
HEATPUMPGULFSTREAM
SPA COPING:
NIA
POOL HEATER SIZE: 136K HI-150
SPA EXTERIOR: N/A
CLEANING LINE: VAC
SPA SPILLWAY SIZE: N/A
AUTOMATED SYSTEM: NIA
CLEANING SYSTEM: NIA
N/A
CHLORINATOR: SALT CHLORINATOR
BLOWER:
N/A
BOOSTER PUMP:
POOL FINISH ITEMS_
COPING: TRAVERTINE 12 X 24
INTERIOR FINISH:
FLORIDA STUCCO
TILE: GLASS 1 X 2
DECK S.F.:
1,950
SWIMOUT: 18 X 8'6"
DECK TYPE: TRAVERTINE FRENCH
CAP TILE r N/A
CAPPING S.F.: NIA
HANDHOLDS: NIA
FOOTERS: 141'
HANDRAIL: N/A
DOD: 3fi'
UMBRELLA SLEEVE: 1 — IN SUN SHELF
PILING POOL: NIA
SPECIAL
NOTES
IT'RAISED BEAM: NIA
ACTUATORS: N/A
12" RAISED BEAM: N/A
ALARMS: DECK MOUNTED
18" RAISED BEAM: I N/A
ELECTRIC: YES
24" RAISED BEAM: N/A
OVERFLOW LINE: IYES
36" RAISED BEAM: N/A
POOL ENCLOSURE SCREEN BY OTHERS
RAISED BEAM FINISH NIA
GATES: NIA
BEAM FINISH SIDES NIA
BABY FENCE: NIA
BEAM FINISH REAR NIA
WATER FEATURES
DECK JETS: NIA
SHEER DESCENT: N/A
BUBBLERS: 2-LED IN SUN SHELF
LYONS HEADS: NIA
AUTO FILL: Nrp,
WATERFALU ROCK N
THERAPYJETS:
N/q
OTHER:
N/A
Digitally signed b
,��►,��a�llFr�,rrrrr
Wayne Markham
...•�N • �y •,
Bennet
i
Date: 2021.06.2
WAYNEMARKHAM BENNETTP.E#51216
MARKHAMSERVICES. INC (CA33018) '15:45:59 -04'0
� * �
- T ' =
182ONEJENSEN BEACHBLVD#6855
;r y�-y: rv,�TgT F
JENSEN BEACH FL34957-7212 6/23/2021
19511818-3825, WW'89+m�pemm
S.f ••. W
IF THERE IS ADIS ITAL SIGNATURE ON THE FRONTIFIRST PAGE OF THIS FILE, THIS SHEET
15 PARTOF A DIGITALLY SIGNED FILEANDDOESNOT REOUREA SEPARATEDIGITAL
/�••. L I. ♦� -.�\
S ....•
'+'' R+
SIGNATURE ON THS SHEET
0 N A
"1811111 1��•,'
IF SIGNED DIGITALLYABOVE PRINTED COPIES OFTHIS DOCUMENT ARE NOT CONSIDEFED
SIGNED AND SEALED A?f] THESIGIATLIHE M0S75EVERFIE0 ON 41y ELECTRONIC COPIES