Loading...
HomeMy WebLinkAboutPOOL SPECIFICATIONS (2)POOL POOL EQUIPMENT SHALL BE SCREENED IF REQUIRED BY LOCAL CODE 5 3" f 4' 7" r— — — — — — — GFI LOCATION MIN 6 & MAX OF 20' TO WATERS EDGE I I � I I FOOTERFOR SCREENEWL06URE 18' x 86" SWIMOUT DECKMOUNTED IN POOLALARMPER FBC7THEDICTION (2020) R4501.17.1.9(3) io c•� TABLE WI BENCH I � �vv f v. _ I I I SF SUNSHELFWI(1) EA BUBBLER &UMBRELLAHOLDER WRbrjvj RESIDENCE NOTE: TOP OF POOL ELEVATION IS 6" LOWER THAN F.F.E. OF HOUSE DECO DRAIN NOTE: POOL CONTRAC rOR TO VERIFY ALL PROPERTY LINE LOCATIONS AND POOL ELEV4TION PRIOR TO CONSTRUCTION. POOL LAYOUT AND DIMENSIONS TO BE VERIFIED WI OWNER PRIOR TO CONS rRUCTION PAGE 1 DRA4ED BY: G.S.M. SCALE: 1/8" = 1' N i UMBRELLA HOLDER 16'7" ;., .:m y i s 3' 7 _ LED BUBBLER - f, 4 ALIED OR .ER DoOtZ WIN�U aw w tit SEE PIPING SCHEMATIC FOR DETAILS AND SIZES PAGE P4 #8 BARE COPPER WIRE FOR 360 DEGREE WITH 4JUMPERS I TO BE 18"-24'FROM WATERS EDGE I I I 23'3" •� OVERFLOW I �61NE I I I o I A I I I CLEANING LINE WITH VAC'LOC FITTING SHALL I BE LOCATED NO GREATER THAN 12' BELOW WATER LEVEL APSP 7SEC4.6 18'2" THOMPSON, DAN 7907 S INDI N RIVER DR FORT PI=RC , FL 34982 DESIGNER reed Esneci ! 1 I I I I i I I 1 1 ! I I I I I I SPECIFICATIONS TURNOVER RATE: 2.39 HR POOL SIZE: 17 X 32' POOL DEPTH: 3' - 5'fi" POOL 84' VOLUME: (GALLONS) 5,155 POOL AREA SQ. FT. 595 ETER: PER POOL & AUXIL IARY POOL EQUIPMENT POOL PUMP: I JANDY FLO PRO 1.65 HP VSP SPA SIZE: N!A POOL FILTER: 200 SF CARTRIDGE SPA POOL S.F./ L.F. /GAL N/A POOL INLETS: 3 SPA JETS: NIA SPA LIGHT: N/A SKIMMER: 1 2 —LED NICHELESS RAISED SPA: NIA POOL LIGHT: POOL HEATER TYPE: HEATPUMPGULFSTREAM SPA COPING: NIA POOL HEATER SIZE: 136K HI-150 SPA EXTERIOR: N/A CLEANING LINE: VAC SPA SPILLWAY SIZE: N/A AUTOMATED SYSTEM: NIA CLEANING SYSTEM: NIA N/A CHLORINATOR: SALT CHLORINATOR BLOWER: N/A BOOSTER PUMP: POOL FINISH ITEMS_ COPING: TRAVERTINE 12 X 24 INTERIOR FINISH: FLORIDA STUCCO TILE: GLASS 1 X 2 DECK S.F.: 1,950 SWIMOUT: 18 X 8'6" DECK TYPE: TRAVERTINE FRENCH CAP TILE r N/A CAPPING S.F.: NIA HANDHOLDS: NIA FOOTERS: 141' HANDRAIL: N/A DOD: 3fi' UMBRELLA SLEEVE: 1 — IN SUN SHELF PILING POOL: NIA SPECIAL NOTES IT'RAISED BEAM: NIA ACTUATORS: N/A 12" RAISED BEAM: N/A ALARMS: DECK MOUNTED 18" RAISED BEAM: I N/A ELECTRIC: YES 24" RAISED BEAM: N/A OVERFLOW LINE: IYES 36" RAISED BEAM: N/A POOL ENCLOSURE SCREEN BY OTHERS RAISED BEAM FINISH NIA GATES: NIA BEAM FINISH SIDES NIA BABY FENCE: NIA BEAM FINISH REAR NIA WATER FEATURES DECK JETS: NIA SHEER DESCENT: N/A BUBBLERS: 2-LED IN SUN SHELF LYONS HEADS: NIA AUTO FILL: Nrp, WATERFALU ROCK N THERAPYJETS: N/q OTHER: N/A Digitally signed b ,��►,��a�llFr�,rrrrr Wayne Markham ...•�N • �y •, Bennet i Date: 2021.06.2 WAYNEMARKHAM BENNETTP.E#51216 MARKHAMSERVICES. INC (CA33018) '15:45:59 -04'0 � * � - T ' = 182ONEJENSEN BEACHBLVD#6855 ;r y�-y: rv,�TgT F JENSEN BEACH FL34957-7212 6/23/2021 19511818-3825, WW'89+m�pemm S.f ••. W IF THERE IS ADIS ITAL SIGNATURE ON THE FRONTIFIRST PAGE OF THIS FILE, THIS SHEET 15 PARTOF A DIGITALLY SIGNED FILEANDDOESNOT REOUREA SEPARATEDIGITAL /�••. L I. ♦� -.�\ S ....• '+'' R+ SIGNATURE ON THS SHEET 0 N A "1811111 1��•,' IF SIGNED DIGITALLYABOVE PRINTED COPIES OFTHIS DOCUMENT ARE NOT CONSIDEFED SIGNED AND SEALED A?f] THESIGIATLIHE M0S75EVERFIE0 ON 41y ELECTRONIC COPIES