HomeMy WebLinkAboutAPPROVED WS 27 - Truss Layout(1)GEARING HEIGHT 5GHEDULE ' MULHERN+KULP STRIPCTU8AL ENGINEERING SUBMITTAL #: 01 ❑ 2 ❑ 3 ❑4 ❑ NO EXCEPTIONS TAKEN ❑REVISE AND RESUBMIT APPROVED AS NOTED ❑REJECTED - RESUBMIT ❑ REVIEWED ONLY ❑ NOT REVIEWED ❑ RESUBMIT FOR RECORD ❑TYPICAL - U.N.O. ❑ FOR RECORD ❑ Shop drawing review is for general conformance with plans, specifications and the design concept of the Project as expressed in the Contract Documents. The corrections or comments made on submittals shall not relieve the Contractor from any obligation contained in the Contract Documents. Review and approval is not for the purpose of determining the completeness, accuracy or correctness of dimensions, quantities or other details. Approval assumes no responsibility whatsoever for the correctness, nor does it imply authorization of additional work. The Structural Engineer's review shall not constitute approval of any fabrication or construction means, methods, techniques, or sequences; or any safety precautions or procedures. REVIEWED BY: BC 068-19051 M+K PROJECT #: 02/18 DATE: 07-20-2021 6 C 6 LL U 6 6 C 6 n 2- 35-00-00 L) U U w w w w w w w w w w w w u U U ,Z,T CJ1 CJ CJ CJ1 CJ3 CJS T19 T16 T17 C�D TIEm T14^ T15 T15 1- 0-0 T15 T15 T15 T15 T15 T15 17-00-00 T149 24" Eep dg. T13 T121 m TI I m T10 T09 TOE CD m CDCJ m Ui CJ I � � T07 T06 T05 T04 U U H1 T03 CJ CJ CJ m mCD HI � 11D m 11 CJ CJSd CJ5 m m CJ3 m CJ1 0 00 J C11011 4-08-00 l 11-08-00 8 -8 brg. Hl=(2) HTU26 NOTES: 1.) REFER TO HID q1 (RECOMMENDATION5 FOR HANDLING INSTALLATION AND TEMPORARY BRACING.) REFER TO ENGINEERED DRAWINGS FOR PERMANENT DRACING REQUIRED, 2.) ALL TRU55E5 (INGLUDIN6 TRU55E5 UNDER VALLEY FRAMING) MUST DE COMPLETELY DECKED OR REFER TO DETAIL V105 FOR ALTERNATE DRACING REQUIREMENT5. 5,) ALL VALLEY5 ARE TO DE CONVENTIONALLY FRAMED DY BUILDER, 4.) ALL TRU55E5 ARE PE516NED FOR 2' o.c. MAXIMUM SPACING, UNLE55 OTHERWISE NOTED. 5.) ALL WALLS SHOWN ON PLACEMENT PLAN ARE CONSIDERED TO DE LOAD BEARING, UNLE55 OTHERWISE NOTED. 6.) 5Y42 TRU55E5 MUST DE INSTALLED WITH THE TOP DEIN6 UP, 7.) ALL ROOF TRU55 HAN6ER5 TO DE 5IMP50N HTU26 UNLE55 OTHERWISE NOTED. ALL FLOOR TRU55 HAN6ER5 TO DE 5IMP50N THA422 UNLE55 OTHERWISE NOTED. 8.) DEAM/HEADER/LINTEL (HP?) TO DE FURNI5HED DY DUILDER, 5HOP DRAWING APPROVAL THI5 LAYOUT 15 THE POLE SOURCE FOR FADRICATION OF TRU55E5 AND VOIDS ALL PPEVIOU5 ARCHITECTURAL OR OTHER TRU55 LAYOUT5. REVIEW AND APPROVAL OF THI5 LAYOUT MUST 5E RECEIVED DEFORE ANY TRU55E5 WILL DE DUILT, VERIFY ALL 60NDITIONS TO IN5URE A605T CHANGES THAT WILL PE5ULT IN EXTRA CHAR6E5 TO YOU. aumman I, Approved Oy LljBuilders M,AFirstSource Orlando PHONE: 407-651-2100 FAX: 407-651-7111 Plant City PHONE: 513-759-5g51 FAX: 015-752-1532 KHovanian Homes .I Lelia -A AL ADHE55: FEV151ON: Lot 27 SCALE: NT[ .. 10KAWN BY: JOD i, 7/12/21 TG/RW 2865295