HomeMy WebLinkAboutGENERAL INFORMATION SECTION A S T , LUUPr
'
Section A (General Information)
Master Permit No. Process No.
Contractors Name: PR-ESTO ROOFING CORPORATION License# CCC055581
Job Address 5412 DAVIS ST, FORT PIERCE FL 34982
ROOF CATEGORY
V'Low Slope ❑Mechanically Fastened Tile Mortar/Adhesive Set Tiles
❑Asphaltic Shingles ❑Metal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑Recovering
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) 3493 Steep Sloped Roof Area (SF) Total(SF) 3493
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
j V
S E T A H D FOOF E O T FOFJ S ET H
i
ST. LUCIE
Section C (Low Slope Roof) Surfacing: —
Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufacturer Zone 1': 8 " oc @ Lap,#Rows 3 8 n ac
(If a component is not used, identify as"NA") Zone 1: 6 " oc @ Lap,#Rows 4 6 "oc
System Manufacturer: POLYGLASS USA INC Zone 2: 6 " oc @ Lap,#Rows 4 @-IL—"Or
Product Approval No.: 19-0311.04 Zone 3: 6 " oc @ Lap,#Rows 5 @ 6 "oc
Number of Fasteners Per Insulation Board:
Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': — Zone 1: — Zone 2: — Zone 3:
Zone V: -37 Zone 1: -64 Zone 2: -84 Zone 3: -115 Illustrate Components Noted and Details as Applicable:
Max. Design Pressure, from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping,
system: Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.,
Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base
Type: PLYWOOD Flashing,Component Material, Material'Thickness, Fastener
Gauge Thickness: 5/8" Type,Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
Slope: 1/2": 12"
Anchor/Base Sheet&No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
FT. N/A
Insulation Base Layer:
Base Insultation Size and Thickness: — Parapet
Base Insulation Fastener/Bonding Material: Height
Top Insulation Layer:
Top Insulation Size and Thickness: — FT. 8'
w cc m m m
Top Insulation Fastener/Bonding Material: x S= D D D
w , co co W
N O O O Mean
Base Sheet(s)&No.of Ply(s): (1) ELASTOBASE 22 m m > Roof
Base Sheet Fastener/Bonding Material: � -0 X X
m Height
1 1/4" R/S NON-CORROSIVE m z D D
G) P <
Ply Sheet(s)'& No. of Ply(s): ELASTOFLEX SA-V FIR -n -n
Ply Sheet Fastener/Bonding Material:
SELFADHERED
Top Ply:ELASTOFLEX SAN FIR
Top Ply Fastener/Bonding Material:
SELF ADHERED