Loading...
HomeMy WebLinkAboutFBC-NON HVHZ EVALUATION OONEMO I etc. APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 5 16 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 6-8 1C Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 8 1D Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 9-10 1E Wood New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 11-13 1F-1 Wood New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 13-16 1F-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 16-18 1G Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 18 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 19-21 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 22-26 2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 27-29 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 30-39 313 Structural concrete New or Reroof(Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier,Bonded Insulation,Bonded Roof Cover 40 3C Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 40 4A LWIC/steel New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 41-42 4B LWIC/structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 43-46 4C LWIC/structural concrete New,Reroof(Tear-Off) A-1 Bonded Vapor Barrier,Bonded Insulation,Bonded Roof Cover 47-48 41) LWIC/steel New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 49-51 4E LWIC/steel or struct.conc. New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 52-57 4F LWIC/steel Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 57 4G LWIC/steel Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 58 SA Cementitious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 59 513 Cementitious wood fiber New or Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 60 5C Cementitious wood fiber Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 61 5D Cementitious wood fiber New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 61 6A Existing gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 62-64 6B Existing gypsum Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 64-65 6C Existing gypsum Reroof(Tear-Off) C Mech.Attached Insulation,Bonded Roof Cover 65 6D Existing gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 66 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 67-74 7B Various Recover F Non-Insulated,Bonded Roof Cover 74 NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 1 of 74 OONEMO I etc. The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2. Unless otherwise noted,fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: OMG#14 Roofgrip with Flat Bottom Plate(Accutrac),OMG HD with OMG 3 in.Galvalume Steel Plate,Dekfast#14 with Hex Plate or 3"Round Insulation Plate,Trufast HD with Trufast 3" Metal Insulation Plates or FlintFast#14 Fastener with FlintFast 3"Insulation Plates. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. ➢ Steel Deck: OMG#12 or#14 Roofgrip with Recessed or Flat Bottom Plate(Accutrac),OMG#12 Standard or HD with OMG 3 in.Galvalume Steel Plate,Dekfast#12 or#14 with Hex Plate or 3"Round Insulation Plate,Trufast DP or HD with Trufast 3"Metal Insulation Plates or FlintFast#12 or#14 Fastener with FlintFast 3"Insulation Plates. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ➢ Structural Concrete: OMG#14 Roofgrip with Recessed or Flat Bottom Plate(Accutrac),OMG HD or CD-10 with OMG 3 in.Galvalume Steel Plate,Dekfast#14 or DekSpike with Hex Plate or 3"Round Insulation Plate,Trufast HD or CF with Trufast 3"Metal Insulation Plates or FlintFast#14 Fastener with FlintFast 3"Insulation Plates. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. 3. Unless otherwise noted,insulation may be any one layer or combination of FBC Approved(Local or Statewide)board(s)that meet FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4. Minimum 200 psi,minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B,C or D,whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type,thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues,such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5. Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(February 2020). 6. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt(HA): Full coverage at 25-30 Ibs/square ➢ Ashland,Inc."Pliodeck Insulation Adhesive"(A-PD): Continuous 0.75 inch wide ribbons,12-inch o.c. Ribbons of subsequent layers shall be perpendicular to those in the layer below. ➢ Dupont"INSTA STIK Quik Set Commercial Roofing Adhesive"(D-IS): Continuous 0.75 to 1 inch wide ribbons,12-inch o.c. ➢ ICP Adhesives and Sealants"Polyset BOARD-MAX": Continuous 3-inch ribbons,12-inch o.c. ➢ ICP Adhesives and Sealants"Polyset CR-20": Continuous 2.5 to 3-inch wide ribbons,12-inch o.c. ➢ HB Fuller"Millennium One Step Foamable Adhesive"(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. ➢ HB Fuller"Millennium PG-1 Pump Grade Adhesive"(M-PG1): Continuous 0.5 to 0.75-inch wide ribbons,12-inch o.c. ➢ OMG OlyBond 500 or OlyBond Green(OB500): Continuous 0.75-inch wide ribbons,12-inch o.c.(PaceCart,SpotShot or Canister) ➢ Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,boards shall be staggered from layer-to-layer. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: ➢ Ashland,Inc."Pliodeck Insulation Adhesive"(A-PD)@ 12-inch o.c. MDP -105.0 psf (Min.1.0-inch) ➢ Ashland,Inc."Pliodeck Insulation Adhesive"(A-PD)@ 6-inch o.c. MDP -277.5 psf (Min.1.0-inch) ➢ Dupont"INSTA STIK Quik Set Commercial Roofing Adhesive"(D-IS): MDP -120.0 psf (Min.1.0-inch) ➢ ICP Adhesives and Sealants"Polyset CR-20": MDP -117.5 psf (Min.1.0-inch) ➢ HB Fuller"Millennium One Step Foamable Adhesive"(M-OSFA): MDP -157.5 psf (Min.1.0-inch) ➢ HB Fuller"Millennium PG-1 Pump Grade Adhesive"(M-PG1): MDP -157.5 psf (Min.1.0-inch) ➢ OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch Multi-Max FA3) ➢ OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch ISO 95+GL) ➢ OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch ENRGY 3) ➢ OMG OlyBond 500(OB500): MDP -487.5 psf (Min.0.5-inch ACFoam II) 8. For adhered roof insulation and board-size: Unless otherwise noted,refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29(February 2020). NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 2 of 74 ONEMOletc. 9. For mechanically attached components or partially-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question,field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type D,the insulation is optional. Alternatively,an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation(Note 5 herein). The separator component shall be documented as meeting FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover in Recover applications. 14. Lightweight insulating concrete(LWIC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted,for systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent'LWIC references,listings were established through testing over lightweight concrete cast using only foaming agent(ASTM C896),water and Portland cement(ASTM C150),with no proprietary additives,in accordance with procedures adopted by Miami-Dade BCCO(FBC CER1592). Use of these listings in new construction or re-roof(tear-off)applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15. Unless otherwise noted,refer to the following references for bonded applications. MEMBRANE/ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base,Flintlastic Ultra Poly SMS Base Note: Base ply cures overnight prior to application of the ply or cap ply. FlintBond Brush or Karnak No.81 Cold Process Modified Bitumen SBS-CAl Ply: Flintlastic Base 20,Flintlastic Poly SMS Base,Flintlastic Ultra Poly SMS Base Adhesive Brush Grade at 1 gal/square Ca PI Flintlastic FR Cap 30,Flintlastic FR Cap 30 CoolStar,Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic P y' Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS,Flintlastic GMS CoolStar BP-CA2 Base Ply: Glasbase,All Weather/Empire Base,Flexiglas Base,Flintlastic Base 20 Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base,Flintlastic Ultra Poly SMS Base SBS-CA2 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base,Flintlastic Ultra Poly SMS Base Henry#903 Adhesive at 1.5 gal/square. Ca PI Flintlastic FR Cap 30,Flintlastic FR Cap 30 CoolStar,Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic p y' Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS,Flintlastic GMS CoolStar BP-CA3 Base Ply: Glasbase,All Weather/Empire Base,Flexiglas Base,Flintlastic Base 20 Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base,Flintlastic Ultra Poly SMS Base Millennium Hurricane Force Membrane Adhesive,beads spaced SBS-CA3 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base,Flintlastic Ultra Poly SMS Base 6-inch o.c. Ca PI Flintlastic FR Cap 30,Flintlastic FR Cap 30 CoolStar,Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic p y' Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS,Flintlastic GMS CoolStar NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 3 of 74 ONEMOjetc. MEMBRANE/ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION Base Ply: Glasbase,All Weather/Empire Base,Flexiglas Base,Flintlastic Base 20 BP-AA hot asphalt at 20-40 Ibs/square Ply: One or more Flintglas Ply 4,Flintglas Premium Ply 6 BP-AA2 Base Ply: Yosemite Venting Base hot asphalt in 24-inch diameter spots in 30-inch grid pattern BP-AA3 Base Ply: Yosemite Venting Base hot asphalt in 9-inch diameter spots in grid pattern noted herein. BP-AA4 Base Ply: Yosemite Venting Base hot asphalt in 9-inch wide ribbons spaced as noted herein. Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base,Flintlastic Ultra Poly SMS Base Ply: One or more Flintlastic Base 20,Flintlastic Poly SMS Base,Flintlastic Ultra Poly SMS Base SBS-AA hot asphalt at 20-40 Ibs/square Ca PI Flintlastic FR Cap 30,Flintlastic FR Cap 30 CoolStar,Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic p y' Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS,Flintlastic GMS CoolStar Base Ply: Flintlastic Ultra Poly SMS Base,Flintlastic Base 20 T SBS-TA Ply: One or more Flintlastic Ultra Poly SMS Base,Flintlastic Base 20 T torch-applied Cap Ply: Flintlastic FR Cap 30 T,Flintlastic FR Cap 30 T CoolStar,Flintlastic GTS-FR,Flintlastic GTS-FR CoolStar Base Ply: One or more Flintlastic APP Base T,Flintlastic STA,Flintlastic STA Plus APP-TA Flintlastic STA,Flintlastic STA Plus,Flintlastic GTA,Flintlastic GTA CoolStar,Flintlastic GTA-FR,Flintlastic torch-applied Cap Ply: GTA-FR CoolStar SBS-SA-H Base Ply: Black Diamond Base Sheet,Flintlastic Ultra Glass SA self-adhering(activated by overlying membrane) Base Ply: Flintlastic SA PlyBase,Flintlastic SA Mid Ply SBS-SA Ply: Flintlastic SA PlyBase,Flintlastic SA Mid Ply self-adhering Cap Ply: Flintlastic SA Cap,Flintlastic SA Cap FR CoolStar,Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar 16. Vapor barrier options for use over structural concrete deck followed by adhesive-applied insulation carry the following Maximum Design Pressure(MDP)limitations. The lesser of the MDP listings below vs.those in Table 3A applies: VAPOR BARRIER OPTIONS,STRUCTURAL CONCRETE DECK,ADHERED INSULATION PER TABLE 3A, (The lesser of the MDP listings below vs.those in Table 3A appliesL... OPTION PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP # TYPE ATTACH (PSF) VB-1. FlintPrime Flintlastic SA PlyBase Self-adhering OB500,12-inch o.c. -82.5 VB-2. None All Weather/Empire Base Sheet; 3-inch wide side laps and 6-inch wide end Millennium Hurricane Force M-OSFA or M-PG1,12-inch o.c. -82.5 laps are sealed with Millennium Hurricane Force Lap and Flashing Adhesive Membrane Adhesive,max.6-inch D.C. Flintlastic Ultra Poly SMS Base Sheet; 3-inch wide side laps and 6-inch wide end Millennium Hurricane Force VB-3. None laps are hot-air-welded,torch-welded or sealed with Millennium Hurricane Membrane Adhesive,max.6-inch D.C. M-OSFA or M-PG1,12-inch o.c. -82.5 Force Lap and Flashing Adhesive VB-4. FlintPrime or FlintPrime SA Black Diamond Base Sheet,Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1,12-inch o.c. -97.5 VB-5. FlintPrime or FlintPrime SA Black Diamond Base Sheet,Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1,6-inch o.c. -315.0 VB-6. FlintPrime Flintlastic GTA Torch-applied M-OSFA or M-PG1,12-inch o.c. -420.0 VB-7. FlintPrime Flintlastic Base 20 T or Flintlastic FR Cap 30 T Torch-applied M-OSFA or M-PG1,12-inch o.c. 495.0 17. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 4 of 74 NNEMOletc. TABLE 1A: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER Base Insulation Top Insulation Roof Cover(Note 15) M Sys. Deck DP No. (Note 1) Type Attach Type Attach Primer Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) SELF-ADHERING SYSTEMS: Min.15/32-inch APA Min.1.5-inch FlintBoard ISO, (Optional)Additional layer(s)of base FlintPrime or W-1 rated CDX plywood;24- ACFoam II,FlintBoard H ISO, M-OSFA or insulation and/or min.0.25-inch M-OSFA orM-PG1 DensDeck Prime or SECUROCK M-PGl FlintPrime SBS-SA (Optional)SBS-SA SBS-SA -60.0 inch span H-Shield SA Gypsum-Fiber Roof Board. Min.15/32-inch APA (Optional)Additional layer(s)of base Min.1.5-inch FlintBoard ISO, M-OSFA or M-OSFA or FlintPrime or W 2 rated CDX plywood;24- ACFoam Il,FlintBoard H ISO, M-PG1,6- insulation and/or min.0.25-inch M-PG1,6- FlintPrime SBS-SA (Optional)SBS-SA SBS-SA -97.5 inch span;blocked 48- DensDeck Prime or SECUROCK inch o.c. H-Shield inch o.c. Gypsum-Fiber Roof Board. inch o.c. SA HYBRID SYSTEMS: Min.15/32-inch APA Min.1.5-inch FlintBoard ISO, (Optional)Additional layer(s)of base (Optional)BP-AA, SBS-AA, 25-inch M-OSFA or 0. W-3 rated CDX plywood;24- ACFoam II,FlintBoard H ISO, M-OSFA or insulation and/or min. None SBS-SA-H SBS-AA,SBS-TA or SBS-TA or -60.0 inch span H-Shield M-PG1 DensDeck Prime or SECUROCK M-PG1 APP-TA APP-TA Gypsum-Fiber Roof Board. Min.15/32-inch APA (Optional)Additional layer(s)of base Min.1.5-inch FlintBoard ISO, M-OSFA or M-OSFA or (Optional)BP-AA, SBS-AA, W 4 rated CDX plywood;24- ACFoam II,FlintBoard H ISO, M-PG1,6- insulation and/or min.0.25-inch M-PG1,6- None SBS-SA-H SBS-AA,SBS-TA or SBS-TA or -97.5 inch span;blocked 48- DensDeck Prime or SECUROCK inch o.c. H-Shield inch o.c. Gypsum-Fiber Roof Board. inch o.c. APP-TA APP-TA CONVENTIONAL SYSTEMS: Min.15/32-inch APA Min.1.5-inch FlintBoard ISO, Optional additional layers of base BP-AA,SBS- (Optional)BP-AA, SBS-AA, M-OSFA or insulation,followed by min.0.25-inch M-OSFA or W-S rated CDX plywood;24- ACFoam II,FlintBoard H ISO, None AA,SBS-TA SBS-AA,SBS-TA or SBS-TA or -60.0 inch span H-Shield M-PG1 DensDeck Prime or SECUROCK M-PG1 or APP-TA APP-TA APP-TA Gypsum-Fiber Roof Board Min.15/32-inch APA Optional additional layers of base Min.1.5-inch FlintBoard ISO, M-OSFA or M-OSFA or BP-AA,SBS- (Optional)BP-AA, SBS-AA, W 6 rated CDX plywood;24- ACFoam Il,FlintBoard H ISO, M-PG1,6- insulation,followed by min.0.25-inch M-PG1,6- None AA,SBS-TA SBS-AA,SBS-TA or SBS-TA or -97.5 inch span;blocked 48- DensDeck Prime or SECUROCK H-Shield inch o.c. inch o.c. or APP-TA APP-TA APP-TA inch o.c. Gypsum-Fiber Roof Board. NEIVIO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 5 of 74 OONEMO I etc. TABLE IB: ... . CONSTRUCTION (TEAR-OFF) BONDEDSYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION, ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) Sys. Deck Attach Primer MDP (Notes 6,7,8) No. (Note 1) Type Fasteners Attach Type Attach Type (Notes 6,7,8) Base Ply Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: Glasbase,All 32 ga.,1-5/8- Min.19/32- Weather Empire, 9-inch o.c.in 4-inch Min.1.5-inch inch dia.tin FlintPrime inch Flexiglas Base, caps with 11 lap and 12-inch o.c. ACFoam II, Min.0.25- or (Optional) - W-7 plywood; Flintlastic Base 20; in two(2),equally FlintBoard ISO, HA inch HA SBS-SA SBS-SA 24-inch Poly SMS;Ultra Poly ga.annular spaced,staggered ENRGY-3,H-Shield DensDeck FlintPrime SBS-SA 45.0* span SMS;Yosemite nils ag shank center rows or Multi-Max FA3 SA Venting Base 32 ga.,1-5/8- HA full HA full Min.19/32- Glasbase,All 8-inch o.c.in 3-inch Min.1.5-inch coverage or coverage or inch dia.tin FlintPrime inch Weather Empire, caps with 11 lap and 8-inch o.c.in ACFoam ll, OB500,M- Min.0.25- OB500,M- or (Optional) W-8 plywood; Flexiglas Base,Poly three(3),equally FlintBoard ISO, OSFA,A-PD,D- inch OSFA,A-PD,D- SBS-SA SBS-SA -52.5 24-inch SMS or Ultra Poly ga.annular spaced,staggered ENRGY-3,H-Shield IS,ICP BOARD- DensDeck IS,ICP BOARD- FlintPrime SBS-SA span SM nails S ring shank center rows or Multi-Max FA3 MAX or CR-20, MAX or CR-20, SA 4-inch o.c. 6-inch o.c. 1-5/8-32 ga., Min.19/32- 8-inch o.c.in 3-inch Min.1.5-inch inch dia.tin FlintPrime inch lap and 8-inch o.c.in ACFoam II, Min.0.25- Yosemite Venting caps with 11 or (Optional) W-9 plywood; Base Sheet ga.annular three(3),equally FlintBoard ISO, HA inch HA SBS-SA SBS-SA -52.5 24-inch spaced,staggered ENRGY-3,H-Shield DensDeck FlintPrime SBS-SA span ling shank center rows or Multi-Max FA3 SA ails 32 ga.,1-5/8- HA full Min.0.25- HA full Min.19/32- Glasbase,All 8-inch o.c.in 3-inch (Optional)Min.1.5- coverage or coverage or inch dia.tin inch FlintPrime inch Weather Empire, lap and 8-inch o.c.in inch ACFoam II, OB500, Gypsum- FlintPrime SBS-SA M- OB500,M- caps with 11 SECUROCK or (Optional) ga.annular W-10 plywood; Flexiglas Base,Poly three(3),equally FlintBoard ISO, OSFA,A-PD,D- OSFA,A-PD,D- SBS-SA SBS-SA -60.0 24-inch SMS or Ultra Poly spaced,staggered ENRGY-3,H-Shield IS,ICP BOARD- IS,ICP BOARD- span SM Board SMS nails shank center rows or Multi-Max FA3 MAX or CR-20, Fiber Roof MAX or CR-20, SA nails 4-inch o.c. 6-inch o.c. 32 ga.,1-5/8- Min.0.25- Min.19/32- inch dia.tin 8-inch o.c.in 3-inch (Optional)Min.1.5- inch FlintPrime inch lap and 8-inch o.c.in inch ACFoam II, Yosemite Venting caps with 11 SECUROCK or (Optional) W-11 plywood; three(3),equally FlintBoard ISO, HA HA SBS-SA SBS-SA -60.0 Base Sheet ga.annular Gypsum- FlintPrime SBS-SA 24-inch ring shank spaced,staggered ENRGY-3,H-Shield Fiber Roof SA span nails center rows or Multi-Max FA3 Board HYBRID SYSTEMS: NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 6 of 74 OONEMO I etc. TABLE IB: ... . CONSTRUCTION (TEAR-OFF) BONDEDSYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION, ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) Sys. Deck MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Primer Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) Glasbase,All 32 ga.,1-5/8- Min.19/32- Weather Empire, inch dia.tin 9-inch o.c.in 4-inch Min.1.5-inch (Optional) inch Flexiglas Base, caps with 11 BP-AA,SBS-lap and 12-inch o.c. ACFoam II, SBS-AA, - W-12 plywood; Flintlastic Base 20; in two(2),equally FlintBoard I50, HA None N/A None SBS-SA-H SBS-TA or ga.annular AA,SBS-TA 45.0* 24-inch Poly SMS;Ultra Poly ring shank spaced,staggered ENRGY-3,H-Shield or APP-TA APP-TA span SMS;Yosemite nails center rows or Multi-Max FA3 Venting Base Min.19/32- 32 ga.,1-5/8- 8-inch o.c.in 3-inch Min.1.5-inch inch Glasbase;Flintglas inch dia.tin lap and 8-inch o.c.in ACFoam II, (Optional) SBS-AA, Premium Ply 6; caps with 11 BP-AA,SBS- W-13 plywood at three(3),equally FlintBoard I50, HA None N/A None SBS-SA-H SBS-TA or -60.0 Yosemite Venting ga.annular AA,SBS-TA max.24- Base ring shank spaced,staggered ENRGY-3,H-Shield or APP-TA nails APP TA inch center rows or Multi-Max FA3 CONVENTIONAL SYSTEMS: Glasbase,All 32 ga.,1-5/8- Min.19/32- Weather Empire, inch dia.tin 9-inch o.c.in 4-inch Min.1.5-inch BP-AA, (Optional) inch Flexiglas Base, lap and 12-inch o.c. ACFoam II, Min.0.25- SBS-AA, W-14 caps with 11 SBS-AA, BP-AA,SBS- - plywood; Flintlastic Base 20; in two(2),equally FlintBoard ISO, HA inch HA FlintPrime SBS-TA or ga.annular SBS-TA or AA,SBS-TA 45.0* 24-inch Poly SMS;Ultra Poly ring shank spaced,staggered ENRGY-3,H-Shield DensDeck APP-TA or APP-TA APP TA span SMS;Yosemite nails center rows or Multi-Max FA3 Venting Base 32 ga.,1-5/8- HA full HA full Min.19/32- Glasbase,All 8-inch o.c.in 3-inch Min.1.5-inch coverage or coverage or inch Weather Empire, inch dia.tin lap and 8-inch o.c.in ACFoam II, OB500,M- Min.0.25- OB500,M- A, (Optional) SBS- caps with 11 SBS-AA, BP-AA,SBS- SBS-AA, ga.annular SBS-TA or AA,SBS-TA W-15 plywood; Flexiglas Base,Poly three(3),equally FlintBoard ISO, OSFA,A-PD,D- inch OSFA,A-PD,D- FlintPrime SBS-TA or -52.5 24-inch SMS or Ultra Poly spaced,staggered ENRGY-3,H-Shield IS,ICP BOARD- DensDeck IS,ICP BOARD- APP-TA span SM nails S ring shank center rows or Multi-Max FA3 MAX or CR-20, MAX or CR-20, APP-TA or APP-TA 4-inch o.c. 6-inch o.c. 1-5/8-32 ga., Min.19/32- 8-inch o.c.in 3-inch Min.1.5-inch inch dia.tin BP-AA, (Optional) inch lap and 8-inch o.c.in ACFoam II, Min.0.25- SBS-AA, Yosemite Venting caps with 11 SBS-AA, BP-AA,SBS- W-16 plywood; three(3),equally FlintBoard I50, HA inch HA FlintPrime SBS-TA or -52.5 Base Sheet ga.annular SBS-TA or AA,SBS-TA 24-inch ring shank spaced,staggered ENRGY-3,H-Shield DensDeck App-TA or APP-TA nails APP-TA span center rows or Multi-Max FA3 32 ga.,1-5/8- HA full Min.0.25- HA full Min.19/32- Glasbase,All 8-inch o.c.in 3-inch (Optional)Min.1.5- coverage or coverage or inch dia.tin inch BP-AA, (Optional) caps with 11 SECUROCK SBS-AA, BP-AA,SBS- inch Weather Empire, lap and 8-inch o.c.in inch ACFoam II, OB500, Gypsum- SBS-TA or AA,SBS-TA M- OB500,M- SBS-AA, ga.annular W-17 plywood; Flexiglas Base,Poly three(3),equally FlintBoard ISO, OSFA,A-PD,D- OSFA,A-PD,D- None SBS-TA or -60.0 24-inch SMSFiber Roof APP-TA or APP-TA or Ultra Poly spaced,staggered ENRGY-3,H-Shield IS,ICP BOARD- IS,ICP BOARD- APP-TA span SM Board SMS nails shank center rows or Multi-Max FA3 MAX or CR-20, MAX or CR-20, nails 4-inch o.c. 6-inch o.c. NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 7 of 74 OONEMO I etc. TABLE 1B: ... . CONSTRUCTION • . BONDEDSYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION, ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) Sys. Deck MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Primer Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) 32 ga.,1-5/8- Min.0.25- Min.19/32- 8-inch o.c.in 3-inch (Optional)Min.1.5- inch dia.tin inch BP-AA, (Optional) inch lap and 8-inch o.c.in inch ACFoam II, SBS-AA, Yosemite Venting caps with 11 SECUROCK SBS-AA, BP-AA,SBS- W-18 plywood; three(3),equally FlintBoard I50, HA HA None SBS-TA or -60.0 24-inch Base Sheet ga.annular Gypsum- SBS-TA or AA,SBS-TA spaced,staggered ENRGY-3,H-Shield APP-TA span ring shank center rows or Multi-Max FA3 Fiber Roof APP-TA or APP-TA nails Board TABLE 1C: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Deck Attach MDP(psf) No. (Note 1) Type Fasteners Attach Type (Notes 6,7,8) Base Ply Ply Cap Ply HYBRID SYSTEMS: Min.1.5-inch ACFoam FlintFast#12 or Min.1.5-inch ACFoam Il, HA,D-IS,M- Min.15/32-inch ll,FlintBoard ISO,H- #14 with 1 per 1.3 plywood;24-inch span Shield or FlintBoard FlintFast 3" ftZ W-19 FlintBoard ISO,H-Shield or OSFA,M-PG1 SBS-SA-H (Optional)APP-TA APP-TA -67.5 ISOH. Insulation Plates FlintBoard ISOH. or OB500 CONVENTIONAL SYSTEMS: Min.0.5-inch Structodek plywood;24-inch span Min.1.5-inch ACFoam ftZ SBS-AA TA or APP-TA High Density Fiberboard (Optional)BP-AA, Min.23/32-inch 1 per 2.0 BP-AA or SBS-AA,SBS- W-20 ll,FlintBoard ISO, Note 2 Roof Insulation,min.0.75- HA SBS-AA,SBS-TA or -45.0 ENRGY 3,H-Shield inch FescoBoard APP-TA (homogeneous) Min.0.25-inch SECUROCK Min.1.5-inch ACFoam BP-AA,SBS- (Optional)BP-AA, Min.23/32-inch 1 per 2.0 Gypsum-Fiber Roof Board, SBS-AA,SBS- * W 21 plywood;24-inch span II,FlintBoard ISO, Note 2 ft2 DensDeck or DensDeck HA AA,SBS-TA SBS AA,SBS TA or TA or APP-TA 45.0 ENRGY 3,H-Shield Prime or APP-TA APP-TA Min.1.5-inch ACFoam FlintFast#12 or Optional additional layer(s) HA,D-IS,M- W 22 Min.15/32-inch II,FlintBoard ISO,H- #14 with 1 per 21.3 of base insulation followed OSFA,M-PG1 APP-TA (Optional)APP-TA APP-TA -90.0 plywood;24-inch span Shield or FlintBoard FlintFast 3" ft by Min.0.25-inch SECUROCK or OB500 ISOH. Insulation Plates Gypsum-Fiber Roof board NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 8 of 74 NNEMOjetc. TABLE 1D: ... . REROOF(TEAR-OFF)OR RECOVER BONDEDSYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, .. System Deck Top Insulation Layer Roof Cover(Note 15) MDP Base Insulation Layer Primer No. (Note 1) Type Fasteners Attach Base Ply Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: Min.15/32-inch (Optional)One or more Min.0.25-inch SECUROCK FlintFast 3 in.Insulation 1 per (Optional)SBS- W-23 plywood;24-inch layers,any combination, Gypsum-Fiber Roof Board Plates with FlintFast#12 or 3.2 ftZ None SBS-SA SA SBS-SA -30.0* span loose laid #14 Min.19/32-inch (Optional)One or more 1 per FlintPrime or (Optional)SBS- W-24 plywood;24-inch layers,any combination, Min.0.25-inch DensDeck Note 2 1.3 ftZ FlintPrime SBS-SA SA SBS-SA -45.0 span loose laid SA Min.19/32-inch (Optional)One or more Min.3/8-inch SECUROCK FlintFast 3 in.Insulation 1 per (Optional)SBS- W-25 plywood;24-inch layers,any combination, Gypsum-Fiber Roof Board Plates with FlintFast#12 or 2.7 ftZ None SBS-SA SA SBS-SA -45.0* span loose laid #14 Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II, FlintFast 3 in.Insulation 1 per FlintPrime or (Optional)SBS- W-26 plywood;24-inch layers,any combination, ENRGY 3,H-Shield,Multi-Max Plates with FlintFast#12 or Z FlintPrime SBS-SA SBS-SA -45.0* span loose laid FA3 or FlintBoard ISO #14 2.0 ft SA SA FlintFast#14 HD with Min.15/32-inch (Optional)One or more FlintFast 3"Insulation Plates 1 per FlintPrime or (Optional)SBS- W-27 plywood;24-inch layers,any combination, Min.1.5-inch FlintBoard ISO or Trufast HD with ionPlates 1.6 ftZ FlintPrime SBS-SA SBS-SA -52.5 Trufast s span loose laid SA SA Metal Insulation Plates Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II, 1 per FlintPrime or (Optional)SBS- W-28 plywood;24-inch layers,any combination, ENRGY 3,H-Shield,Multi-Max Note 2 1.5 ftZ FlintPrime SBS-SA SA SBS-SA -60.0 span loose laid FA3 or FlintBoard ISO SA HYBRID SYSTEMS: Min.15/32-inch (Optional)One or more FlintFast 3 in.Insulation (Optional)BP- Min.0.25-inch DensDeck; plates with FlintFast#12 or 1 per Z None SBS-SA- AA,SBS-AA, SBS-AA,SBS- 30.0* span loose laid DensDeck Prime #14 2.0 ft H SBS-TA or APP- TA or APP-TA TA Min.15 32-inch FlintFast#14 HD with / (Optional)One or more FlintFast 3"Insulation Plates 1 per SBS-SA- (Optional)SBS- SBS-TA or W-30 plywood;24-inch layers,any combination, Min.1.5-inch FlintBoard ISO or Trufast HD with Trufast 3" 1.6 ftZ None H TA or APP-TA APP-TA -52.5 span loose laid Metal Insulation Plates Min.15/32-inch (Optional)One or more Min.1.5-inch ACFoam II, 1 per SBS-SA- (Optional)BP- W-31 plywood;24-inch layers,any combination, FlintBoard ISO,ENRGY 3 or Note 2 1.3 ftZ None H AA or SBS-AA SBS-AA -52.5 span loose laid Multi-Max FA3 Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II, (Optional)BP- 1 per SBS-SA- AA,SBS-AA, SBS-AA,SBS W-32 plywood;24-inch layers,any combination, FlintBoard ISO,H-Shield, Note 2 1.5 ftZ None H SBS-TA or APP- TA or APP-TA -60.0 span loose laid FlintBoard ISOH TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 9 of 74 NNEMOjetc. TABLE 1D: ... . REROOF(TEAR-OFF)OR RECOVER BONDEDSYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, .. System Deck Base Insulation Layer Primer Top Insulation Layer Roof Cover(Note 15) MDP No. (Note 1) Type Fasteners Attach Base Ply Ply Cap Ply (psf) Min.15/32-inch (Optional)Min.1.5-inch,One Min.1.5-inch ACFoam II, FlintFast 3 in.Insulation (Optional)SBS W-33 plywood;24-inch or more layers,any FlintBoard ISO,H-Shield, Plates with FlintFast#12 or 1 pe Z None SBS-SA- AA SBS-TA or SBS-rA,SBS- -75.0 span combination,loose laid FlintBoard ISOH #14 1.3 ft H APP TA TA or APP-TA Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II, 1 per SBS-SA- (Optional)SBS- SBS-TA or W-34 plywood;24-inch layers,any combination, FlintBoard ISO,ENRGY 3 or Note 2 1.3 ftZ None H TA or APP-TA APP-TA 82.5 span loose laid Multi-Max FA3 CONVENTIONAL SYSTEMS: Min.0.5-inch Structodek High (Optional)BP- Min.plywood; 24-inc (Optional)One bi more Density Fiberboard Roof 1 per BP-AA or AA,SBS-AA, SBS-AA,SBS * W 35 plywood;24-inch layers,any combination, Insulation,min.0.75-inch Note 2 2.0 ftZ None SBS-AA SBS-TA or APP- TA or APP-TA 45.0 span loose laid FescoBoard(homogeneous) TA BP-AA, (Optional)BP- Min.15/32-inch (Optional)One or more Min.0.25-inch SECUROCK SBS-AA, FlintFast#12 or#14 HD with 1 per AA,SBS-AA, SBS-AA,SBS- W-36 plywood;24-inch layers,any combination, Gypsum-Fiber Roof Board, FlintFast 3"Insulation Plates 2.0 ftZ None SBS-TA SBS-TA or APP- TA or APP-TA -45.0* span loose laid DensDeck or DensDeck Prime or APP- TA TA Min.15/32-inch (Optional for Recover)Min. Min.0.25-inch SECUROCK FlintFast#12 or#14 HD with 1 per (Optional)APP- W-37 plywood;24-inch 1.5-inch,One or more layers, Gypsum-Fiber Roof Board FlintFast 3"Insulation Plates 1.5 ftZ None APP-TA TA APP-TA -60.0 span any combination,loose laid (Optional for Concrete or BP-AA, (Optional)BP- Min.19/32-inch SBS-AA, Recover)Min.2-inch ACFoam Min.0.5-inch SECUROCK FlintFast#12 or#14 HD with 1 per AA,SBS-AA, SBS-AA,SBS- W-38 plywood;24-inch II,FlintBoard,H-Shield or Gypsum-Fiber Roof Board FlintFast 3"Insulation Plates 1.8 ftZ None SBS-TA SBS-TA or APP- TA or APP-TA -60.0 span ENRGY 3,loose laid. or APP TA TA Min.15/32-inch (Optional for Recover)Min. Min.0.25-inch SECUROCK FlintFast#12 or#14 HD with 1 per (Optional)APP- W-39 plywood;24-inch 1.5-inch,One or more layers, Gypsum-Fiber Roof Board FlintFast 3"Insulation Plates 1.3 ftZ None APP-TA TA APP-TA -67.5 span any combination,loose laid NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEIVIO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 10 of 74 NNEMOjetc. TABLE 1E: DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPED: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Insulation Layer(s)(Note 13) Base Sheet Roof Cover(Note 15) MD P Primer No. (Note 1) Type Attach Type Fasteners Attach Base Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: Min.19/32-inch Min.1.5-inch,One 8-inch o.c.at min.3-inch lap FlintPrime or Prelim. Flintlastic SA Note 2 and 8-inch o.c.in two(2), FlintPrime (Optional) SBS-SA -82.5* W-40 plywood;24-inch or more layers, Attach NailBase equally spaced,staggered SBS-SA span any combination SA at plates center rows FlintFast 3 in.Insulation Plates with FlintFast#12 or#14; 6-inch o.c.at min.2-inch lap Min.15/32-inch Min.1.5-inch,One FlintPrime or Prelim. Flintlastic SA Trufast 3"Metal Insulation and 6-inch o.c.in three(3), (Optional) W-41 plywood;24-inch or more layers, Attach NailBase Plates with DP or HD;OMG 3 in. equally spaced,staggered FlintPrime SBS-SA SBS-SA 97.5* span any combination Round Metal Plates with OMG center rows SA at plates #14 HD FlintFast 3 in.Insulation Plates with FlintFast#12 or#14; 6-inch o.c.at min.2-inch lap Min.15/32-inch Min.1.5-inch,One FlintPrime or Prelim. Flintlastic SA Trufast 3"Metal Insulation and 6-inch o.c.in four(4), (Optional) W-42 plywood;24-inch a more layers, Attach NailBase Plates with DP or HD;OMG 3 in. equally spaced,staggered FlintPrime SBS-SA SBS SA 127.5* span any combination Round Metal Plates with OMG center rows SA at plates #14 HD HYBRID SYSTEMS: FlintFast 3 in.Insulation Plates Glasbase;Flexiglas; with FlintFast#12 or#14; Min.15/32-inch Min.1.5-inch,One 6-inch o.c.at 4-inch lap and 6- FlintPrime or SBS-AA, Prelim. Flintlastic Base 20; Trufast 3"Metal Insulation W-43 plywood;24-inch or more layers, inch o.c.in three(3),equally FlintPrime SBS-SA-H SBS-TA or -97.5 span any combination Attach Poly SMS Base;Ultra Plates with DP or HD;OMG 3 in. spaced,staggered center rows SA at plates APP-TA Poly SMS Base Round Metal Plates with OMG #14 HD Min.19/32-inch Min.1.5-inch,One Glasbase;Flexiglas; 7-inch o.c.at 3-inch lap and 7- SBS-AA, W-44 plywood;24-inch or more layers, Prelim. Flintlastic Base 20;gttach Poly SMS Base;Ultra Note 2 inch o.c.in three(3),equally None SBS-SA-H SBS-TA or -105.0 span any combination Poly SMS Base spaced,staggered center rows APP-TA FlintFast 3 in.Insulation Plates Glasbase;Flexiglas; with FlintFast#12 or#14; Min.15/32-inch Min.1.5-inch,One 6-inch o.c.at 4-inch lap and 6- FlintPrime or SBS-AA, Prelim. Flintlastic Base 20; Trufast 3"Metal Insulation W-45 plywood;24-inch or more layers, inch o.c.in four(4),equally FlintPrime SBS-SA-H SBS-TA or -127.5 Attach Poly SMS Base;Ultra Plates with DP or HD;OMG 3 in. span any combination Poly SMS Base Round Metal Plates with OMG spaced,staggered center rows SA at plates APP-TA #14 HD CONVENTIONAL SYSTEMS: NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 11 of 74 NNEMOjetc. TABLE 1E: DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPED: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Insulation Layer(s)(Note 13) Base Sheet Primer Roof Cover(Note 15) MDP No. (Note 1) Type Attach Type Fasteners Attach Base Ply Cap Ply (psf) Glasbase;All Min.23/32-inch Min.1.5-inch,One Weather/Empire 12-inch o.c.at 4-inch lap and BP-AA,SBS- SBS-AA, W-46 plywood;24-inch or more layers, Prelim. Base;Flexiglas Base; Note 2 36-inch o.c.in two(2),equally None AA,SBS-TA SBS-TA or -30.0* span any combination Attach Flintlastic Base 20; spaced,staggered center rows or APP-TA APP-TA Yosemite Venting Base Glasbase;All Min.23/32-inch Min.1.5-inch,One Weather/Empire 12-inch o.c.at 4-inch lap and BP-AA,SBS- SBS-AA, W-47 plywood;24-inch or more layers, Prelim. Base;Flexiglas Base; Note 2 24-inch o.c.in two(2),equally None AA,SBS-TA SBS-TA or -45.0* span any combination Attach Flintlastic Base 20; spaced,staggered center rows or APP-TA APP-TA Yosemite Venting Base Min.23/32-inch Min.1.5-inch,One 12-inch o.c.at 4-inch lap and BP-AA,SBS- SBS-AA, W 48 Prelim. Poly SMS Base;Ultra plywood;24-inch or more layers, Attach Poly SMS Base Note 2 36-inch o.c.in two(2),equally None AA,SBS-TA SBS-TA or -45.0* span any combination spaced,staggered center rows or APP-TA APP-TA Glasbase;Flexiglas; FlintFast 3 in.Insulation Plates Flintlastic Base 20; with FlintFast#12 or#14; (Optional) Min.15/32-inch Min.1.5-inch,One All Weather/Empire 6-inch o.c.at 4-inch lap and 6- SBS-AA, SBS- Prelim. Trufast 3"Metal Insulation , W-49 plywood;24-inch or more layers, Base;Poly SMS Base; inch o.c.in three(3),equally None BP-AA SBS-TA or -97.5 span any combination Attach Ultra Poly SMS Base; Plates with DP or HD;OMG 3 in. spaced,staggered center rows. AA,SBS-TA APP-TA Yosemite Venting Round Metal Plates with OMG or APP-TA Base #14 HD Min.15/32-inch Min.1.5-inch,One Prelim. OMG 3 in.Round Metal Plates 6-inch o.c.at 4-inch lap and 6- W-50 plywood;24-inch or more layers, Attach Flintlastic APP Base T with OMG#14 HD inch o.c.in three(3),equally None APP-TA APP-TA -97.5 span any combination spaced,staggered center rows. Glasbase;Flexiglas; Flintlastic Base 20; One or more FlintFast 3 in.Insulation Plates (Optional) Min.15/32-inch layers,any Prelim. All Weather/Empire with FlintFast#14;Trufast 3" 8-inch o.c.at 4-inch lap and 8 BP-AA,SBS- SBS-AA, Metal Insulation Plates with W-51 plywood;24-inch Base;Poly SMS Base; inch o.c.at three(3)equally None SBS-TA or -97.5 combination Trufast HD or span thickness or Attach Ultra Poly SMS Base; spaced,staggered center rows or APP-TA SBS-TA APP_TA P-T Yosemite Venting Base Glasbase;Flexiglas; Min.19/32-inch Min.1.5-inch,One Flintlastic Base 20; 7-inch o.c.at 3-inch lap and 7- BP-AA,SBS- SBS-AA, W-52 plywood;24-inch or more layers, Prelim. Poly SMS Base;Ultra Note 2 inch o.c.in three(3),equally None AA,SBS-TA SBS-TA or -105.0 span any combination Attach Poly SMS Base; spaced,staggered center rows or APP-TA APP-TA Yosemite Venting Base NEIVIO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEIVIO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 12 of 74 NNEMOjetc. TABLE 1E: DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPED: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Insulation Layer(s)(Note 13) Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Type Attach Type Fasteners Attach Primer Base Ply Cap Ply (psf) Min.19/32-inch Min.1.5-inch,One Prelim. OMG 3 in.Round Metal Plates 7-inch o.c.at 3-inch lap and 7- W-S3 plywood;24-inch or more layers, Attach Flintlastic APP Base T with OMG#14 HD or Dekfast inch o.c.in three(3),equally None APP-TA APP-TA -105.0 span any combination Hex Plate with Dekfast#14 spaced,staggered center rows Glasbase;Flexiglas; FlintFast 3 in.Insulation Plates Flintlastic Base 20; with FlintFast#12 or#14; (Optional) Min.15/32-inch Min.1.5-inch,One 6-inch o.c.at 4-inch lap and 6- SBS-AA, Prelim. Poly SMS Base;Ultra Trufast 3"Metal Insulation BP-AA,SBS- W-54 plywood;24-inch or more layers, Attach Poly SMS Base; Plates with DP or HD;OMG 3 in. inch o.c.in four(4),equally None AA SBS-TA SBS-TA or -127.5 span any combination Yosemite Venting Round Metal Plates with OMG spaced,staggered center rows. or APP-TA APP-TA Base #14 HD Min.15/32-inch Min.1.5-inch,One Prelim. OMG 3 in.Round Metal Plates 6-inch o.c.at 4-inch lap and 6- W-55 plywood;24-inch or more layers, Attach with OMG#14 HD Flintlastic APP Base T inch o.c.in four(4),equally None APP-TA APP-TA -127.5 span any combination spaced,staggered center rows. COLD-APPLIED SYSTEMS: Glasbase;Flexiglas Base;Flintlastic Base 20;All Weather/ FlintFast 3 in.Insulation Plates Min.15/32-inch Min.1-inch,One Loose- Empire Base; with FlintFast#12 or#14; 8-inch o.c.at 4-inch lap and 8- (Optional) W-56 plywood;24-inch or more layers, laid Yosemite Venting withTruf FlintFast 3"Metal Insulation inch o.c.in three(3),equally None SBStion SBS-CA1 -52.5 span any combination Base;Flintlastic Poly Plates with DP or HD spaced,staggered center rows SMS Base;Flintlastic Ultra Poly SMS Base TABLE IF-1: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) • BONDED ROOFCOVER System Deck Base Sheet Roof Cover(Note 15) MDP Primer No. (Note 1) Base Fasteners Attach Base Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: Min.15/32-inch 9-inch o.c.at min.3-inch lap and 12-inch FlintPrime (Optional) W S7 plywood;24-inch span Flintlastic SA NailBase Simplex MAXX Cap o.c.in two(2),equally spaced,staggered at plates SBS-SA SBS-SA -45.0* center rows 6-inch o.c.at min.2-inch lap and 6-inch W 58 Min. 2-inch Flintlastic SA NailBase Min. inch long,12 ga.Simplex Metal o.c.in four(4),equally spaced, None (Optional) SBS-SA -52.5 plywood;od;24-inch span Cap Nails SBS-SA staggered center rows Min.19/32-inch 8-inch o.c.at min.2-inch lap and 8-inch W-59 plywood;24-inch Flintlastic SA NailBase 32 ga.,annular ring an tin caps with 11 o.c.in three(3),equally spaced, None (Optional) SBS-SA -52.5 span ga.annular ring shank nails staggered center rows SBS-SA NEIVIO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TR EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 13 of 74 NNEMOjetc. TABLE 1F-1: ... . CONSTRUCTION (TEAR-OFF) BONDEDSYSTEIVITYPEE: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET, System Deck Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Base Fasteners Attach Primer Base Ply Cap Ply (psf) APA rated,min.7/16 (Optional) 8-inch o.c.at min.3-inch lap and 8-inch W-60 CAT,0.418 in., Flintlastic SA NailBase Simplex MAXX Cap o.c.in three(3),equally spaced, FlintPrime Flintlastic SA SBS-SA -52.5 Exposure 1,OSB;24- at plates Mid Ply,self- inch span staggered center rows adhering 8-inch o.c.at min.2-inch lap and 8-inch W-61 Min.plywood; 2-inch Flintlastic SA NailBase 32 ga.,annular ring inch dia.tin caps with 11 o.c.in three(3),equally spaced, None (Optional) SBS-SA -60.0 plywood;24-inch span ga.annular ring shank nails staggered center rows SBS-SA 8-inch o.c.at min.3-inch lap and 8-inch W 62 Min. o 2-inch Flintlastic SA NailBase Simplex MAXX Cap o.c.in three(3),equally spaced, FlintPrime (Optional) plywood;24-inch span at plates SBS SA SBS-SA -67.5 d; staggered center rows 6-inch o.c.at min.2-inch lap and 6-inch W 63 Min.plywood; 2-inch Flintlastic SA NailBase 32 ga.,annular ring inch dia.tin caps with 11 o.c.in four(4),equally spaced, None (Optional) SBS-SA -75.0 plywood;24-inch span ga.annular ring shank nails staggered center rows SBS-SA Cap nails:1-inch diameter,0.032-inch 7-inch o.c.at min.4-inch laps and 7-inch W-64 Min. o 2-inch Flintlastic SA NailBase thick metal cap with 0.120"shank o.c.in five(5),equally spaced,staggered None (Optional) plywood;24-inch span SBS-SA SBS-SA -75.0 d; diameter,annular ring shank nails center rows 4-inch o.c.at min.2-inch lap and 4-inch W-65 Min.plywood; 2-inch Flintlastic SA NailBase 32 ga.,annular ring inch dia.tin caps with 11 o.c.in four(4),equally spaced, None (Optional) SBS-SA -105.0 plywood;24-inch span ga.annular ring shank nails staggered center rows SBS-SA HYBRID SYSTEMS: Glasbase;Flexiglas;Flintlastic Base 9-inch o.c.at 4-inch lap and 12-inch o.c. W-66 Min.plywood; 2-inch 20;All Weather/Empire Base;Poly 32 ga.,annular ring inch dia.tin caps with 11 in two(2),equally spaced,staggered None SBS-SA-H SBS-AA,SBS- -45.0* plywood;24-inch span SMS Base;Ultra Poly SMS Base ga.annular ring shank nails center rows TA or APP-TA Min.15/32-inch Glasbase;Flexiglas;Flintlastic Base Min.1-inch long,12 ga.Simplex Metal 6-inch o.c.at 3-inch lap and 6-inch o.c.in SBS-AA,SBS- W 67 plywood;24-inch span 20;All Weather/Empire Base;Poly Cap Nails four(4),equally spaced,staggered None SBS-SA-H TA or APP-TA -52.5 SMS Base;Ultra Poly SMS Base center rows Min.19/32-inch Glasbase;Flexiglas;Flintlastic Base 32 ga.,1-5/8-inch dia.tin caps with 11 8-inch o.c.at 4-inch lap and 8-inch o.c.in SBS-AA,SBS- W 68 plywood;24-inch span 20;Poly SMS Base;Ultra Poly SMS ga.annular ring shank nails three(3),equally spaced,staggered None SBS-SA-H TA or;PP-TA -52.5 Base center rows Min.19/32-inch Glasbase;Flexiglas;Flintlastic Base 32 ga.,1-5/8-inch dia.tin caps with 11 8-inch o.c.at 4-inch lap and 8-inch o.c.in SBS-AA,SBS- W-69 20;Poly SMS Base;Ultra Poly SMS three(3),equally spaced,staggered None SBS-SA-H -60.0 plywood;24-inch span Base ga.annular ring shank nails center rows TA or APP-TA Min.19/32-inch Glasbase;Flexiglas;Flintlastic Base 32 ga.,1-5/8-inch dia.tin caps with 11 6-inch o.c.at 4-inch lap and 6-inch o.c.in SBS-AA,SBS- W 70 plywood;24-inch span 20;Poly SMS Base;Ultra Poly SMS ga.annular ring shank nails four(4),equally spaced,staggered None SBS-SA-H TA or APP-TA 82.5 Base center rows Min.19/32-inch Glasbase;Flexiglas;Flintlastic Base 32 ga.,1-5/8-inch dia.tin caps with 11 4-inch o.c.at 3-inch lap and 4-inch o.c.in SBS-AA,SBS- W 71 plywood;24-inch span 20;Poly SMS Base;Ultra Poly SMS ga.annular ring shank nails four(4),equally spaced,staggered None SBS-SA-H TA or APP-TA 105.0 Base center rows NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 14 of 74 NNEMOletc. TABLE 1F-1: ... . CONSTRUCTION (TEAR-OFF) BONDEDSYSTEMTYPEE: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET, System Deck Base Sheet Roof Cover(Note 15) MDP Primer No. (Note 1) Base Fasteners Attach Base Ply Cap Ply (psf) CONVENTIONAL SYSTEMS: Glasbase;Flexiglas;Flintlastic Base 9-inch o.c.at 4-inch lap and 12-inch o.c. BP-AA,SBS- Min.19/32-inch 20;All Weather/Empire Base;Poly 32 ga.,1-5/8-inch dia.tin caps with 11 SBS-AA,SBS- W 72 plywood;24-inch span SMS Base;Ultra Poly SMS Base; ga.annular ring shank nails in two(2),equally spaced,staggered None AA,SBS-TA or TA or APP-TA 45.0* Yosemite Venting Base center rows APP TA Glasbase;Flexiglas;Flintlastic Base 9-inch o.c.at 2-inch lap and 18-inch o.c. (Optional)BP- W 73 Min.15/32-inch 20;All Weather Empire Base;Poly Simplex MAXX Ca in two(2),equally spaced,staggered None AA,SBS-AA, SBS-AA,SBS- -45.0* plywood;24-inch span / p y p P ( ) q y p gg SBS-TA or TA or APP-TA SMS Base;Yosemite Venting Base center rows APP TA Min.15/32-inch 9-inch o.c.at 2-inch lap and 18-inch o.c. (Optional) W 74 plywood;24-inch span Flintlastic APP Base T Simplex MAXX Cap in two(2),equally spaced,staggered None APP TA APP-TA -45.0* center rows Glasbase;Flexiglas;Flintlastic Base (Optional)BP- Min.15/32-inch 20;All Weather/Empire Base;Poly Min.1-inch long,12 ga.Simplex Metal four( ),e u ll inch lap and 6-inch o.c.in AA,SBS-AA, SBS-AA,SBS- W 75 plywood;24-inch span SMS Base;Ultra Poly SMS Base; Cap Nails four(4),equally spaced,staggered None SBS-TA or TA or APP-TA 52.5 center rows Yosemite Venting Base APP-TA Glasbase;Flexiglas;Flintlastic Base 8-inch o.c.at 4-inch lap and 8-inch o.c.in BP-AA,SBS- Min.19/32-inch 20;All Weather/Empire Base;Poly 32 ga.,1-5/8-inch dia.tin caps with 11 three center rows SBS-AA,SBS- 52.5 W 76 plywood;24-inch span SMS Base;Ultra Poly SMS Base; ga.annular ring shank nails ro ws APP TA equally spaced,staggered None AA,SBS TA or TA or APP-TA Yosemite Venting Base Glasbase;Flexiglas;Flintlastic Base 9-inch o.c.at 2-inch lap and 12-inch o.c. (Optional)BP- W 77 Min.15/32-inch 20;All Weather/Empire Base;Poly Simplex MAXX Cap in two(2),equally spaced,staggered None AA,SBS-AA, SBS-AA,SBS- -52.5 plywood;24-inch span SBS-TA or TA or APP-TA SMS Base;Yosemite Venting Base center rows APP TA Min.15/32-inch 9-inch o.c.at 2-inch lap and 12-inch o.c. (Optional) W 78 plywood;24-inch span Flintlastic APP Base T Simplex MAXX Cap in two(2),equally spaced,staggered None APP TA APP-TA -52.5 center rows Glasbase;Flexiglas;Flintlastic Base 8-inch o.c.at 4-inch lap and 8-inch o.c.in BP-AA,SBS- Min.19/32-inch 20;All Weather/Empire Base;Poly 32 ga.,1-5/8-inch dia.tin caps with 11 three center rows SBS-AA,SBS 60.0 W 79 plywood;24-inch span SMS Base;Ultra Poly SMS Base; ga.annular ring shank nails ro ws APP-TA equally spaced,staggered None AA,SBS-TA or TA or APP-TA Yosemite Venting Base Glasbase;Flexiglas;Flintlastic Base Cap nails:1-inch diameter,0.032-inch 6-inch o.c.at 4-inch lap and 6-inch o.c. (Optional)BP- Min.15/32-inch 20;All Weather/Empire Base;Poly SBS-AA or W-80 thick metal cap with 0.120-inch shank at five(5)equally spaced,staggered None AA,SBS-AA or -67.5 plywood;24-inch span SMS Base;Ultra Poly SMS Base; diameter,annular ring shank nails. center rows SBS-TA SBS-TA Yosemite Venting Base Glasbase;Flexiglas;Flintlastic Base 6-inch o.c.at 4-inch lap and 6-inch o.c.in BP-AA,SBS- Min.19/32-inch 20;All Weather/Empire Base;Poly 32 ga.,1-5/8-inch dia.tin caps with 11 SBS-AA,SBS- W 81 plywood;24-inch span SMS Base;Ultra Poly SMS Base; ga.annular ring shank nails four(4),equally spaced,staggered None AA,SBS-TA or TA or APP-TA 82.5 Yosemite Venting Base center rows APP-TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEIVIO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 15 of 74 NNEMOjetc. TABLE 1F-1: ... . CONSTRUCTION (TEAR-OFF) BONDEDP SYSTEMTYPEE: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET, System Deck Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Base Fasteners Attach Primer Base Ply Cap Ply (psf) Glasbase;Flexiglas;Flintlastic Base 6-inch o.c.at 2-inch lap and 6-inch o.c.in (Optional)BP- W 82 Min.15/32-inch 20;All Weather/Empire Base;Poly Simplex MAXX Cap two(2),equally spaced,staggered None AA,SBS-AA, SBS-AA,SBS- -90.0 plywood;24-inch span SBS-TA or TA or APP-TA SMS Base;Yosemite Venting Base center rows APP-TA Min.15/32-inch 6-inch o.c.at 2-inch lap and 6-inch o.c.in (Optional) W 83 plywood;24-inch span Flintlastic APP Base T Simplex MAXX Cap two(2),equally spaced,staggered None APP TA APP-TA -90.0 center rows Glasbase;Flexiglas;Flintlastic Base 4-inch o.c.at 3-inch lap and 4-inch o.c.in BP-AA,SBS- Min.19/32-inch 20;All Weather/Empire Base;Poly 32 ga.,1-5/8-inch dia.tin caps with 11 SBS-AA,SBS W 84 plywood;24-inch span SMS Base;Ultra Poly SMS Base; ga.annular ring shank nails four(4),equally spaced,staggered None AA,SBS-TA or TA or APP-TA 105.0 Yosemite Venting Base center rows APP-TA Glasbase;Flexiglas;Flintlastic Base 6-inch o.c.at 2-inch lap and 6-inch o.c.in (Optional)BP- Min.15/32-inch AA,SBS-AA, SBS-AA,SBS- W 85 plywood;24-inch span 20;All Weather/Empire Base;Poly Simplex MAXX Cap three(3),equally spaced,staggered None SBS-TA or TA or APP-TA -105.0 SMS Base;Yosemite Venting Base center rows APP-TA 6-inch o.c.at 2-inch lap and 6-inch o.c.in W 86 Min. o 2-inch Flintlastic APP Base T Simplex MAXX Cap three(3),equally spaced,staggered None (Optional) plywood;24-inch span APP-TA APP-TA -105.0 d; center rows TABLE 1F-2: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE E: • BONDED ROOFCOVER System Primer 7(Note Base Sheet Roof Cover(Note 15) MDP No. 1) Base Fasteners Attach Base Ply I Cap Ply (psf) SELF-ADHERING SYSTEMS: APA rated,min. (Optional) Flintlastic SA NailBase 9-inch stag at min.3-inch lap and 7/16 CAT,0.418 in., Trufast Versa Fasteners&Plates;two(2) FlintPrime at Flintlastic SA Exposure 1,OSB; screws per plate at 180°from each other* spaced, stag in two(2),equally staggered center rows plates Mid Ply,self- SBS-SA 60.0* W-87 24-inch span , adhering Note: *For re-roof(tear-off)or recover applications,field withdrawal resistance testing(Note 11)shall yield minimum 109lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance. For recover installations,screws shall be of sufficient length for minimum 1"penetration through O58 sheathing. Min.19/32-inch 8-inch o.c.at min.3-inch lap and FlintPrime or (Optional) W-88 plywood;24-inch Flintlastic SA NailBase Note 2 8-inch o.c.in two(2),equally FlintPrime SA SBS-SA -82.5* span spaced,staggered center rows at plates SBS-SA FlintFast 3 in.Insulation Plates with FlintFast Min.15/32-inch 6-inch stag at min.2-inch lap and FlintPrime or #12 or#14;Trufast 3"Metal Insulation Plates (Optional) W-89 plywood;24-inch Flintlastic SA NailBase with DP or HD;OMG 3 in.Round Metal Plates 6-inch stag in three(3),equally FlintPrime SA SBS-SA SBS-SA -97.5* span spaced,staggered center rows at plates with OMG#14 HD NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TR EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMD ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 16 of 74 NNEMOjetc. System Deck Base Sheet Primer Roof Cover(Note 15) MDP No. (Note 1) Base Fasteners Attach Base Ply Cap Ply (psf) FlintFast 3 in.Insulation Plates with FlintFast Min.15/32-inch 6-inch o.c.at min.2-inch lap and FlintPrime or #12 or#14;Trufast 3"Metal Insulation Plates (Optional) W-90 plywood;24-inch Flintlastic SA NailBase with DP or HD;OMG 3 in.Round Metal Plates 6-inch o.c.in four(4),equally FlintPrime SA SBS-SA with OMG#14 HD SBS-SA -127.5* span spaced,staggered center rows at plates HYBRID SYSTEMS: Insulation Plates with FlintFast Min.15/32-inch Glasbase;Plexiglas;Flintlastic Base FlintFast 3 in. 6-inch o.c.at 4-inch lap and 6- FlintPrime or #12 or#14;Trufast 3"Metal Insulation Plates SBS-AA,SBS W-91 plywood;24-inch 20;Poly SMS Base;Ultra Poly 5M5 with DP or HD;OMG 3 in.Round Metal Plates inch o.c.in three(3),equally FlintPrime SA SBS-SA-H TA or APP-TA 97.5 span Base spaced,staggered center rows at plates with OMG#14 HD Min.19/32-inch Glasbase;Flexiglas;Flintlastic Base 7-inch o.c.at 3-inch lap and 7- SBS-AA,SBS- W-92 plywood;24-inch 20;Poly SMS Base;Ultra Poly SMS Note 2 inch o.c.in three(3),equally None SBS-SA-H TA or APP-TA -105.0 span Base spaced,staggered center rows Min.15/32-inch Glasbase;Plexiglas;Flintlastic Base FlintFast 3 in.Insulation Plates with FlintFast 6-inch o.c.at 4-inch lap and 6- FlintPrime or #12 or#14;Trufast 3"Metal Insulation Plates SBS-AA,SBS- W-93 plywood;24-inch 20;Poly SMS Base;Ultra Poly SMS with DP or HD;OMG 3 in.Round Metal Plates inch o.c.in four(4),equally FlintPrime SA SBS-SA-H TA or APP-TA -127.5 span Base spaced,staggered center rows at plates with OMG#14 HD CONVENTIONAL SYSTEMS: Min.23/32-inch Glasbase;All Weather/Empire 12-inch o.c.at 4-inch lap and 36- BP-AA,SBS- SBS-AA,SBS- W-94 plywood;24-inch Base;Flexiglas Base;Flintlastic Note 2 inch o.c.in two(2),equally None AA,SBS-TA -30.0* span Base 20;Yosemite Venting Base spaced,staggered center rows or APP-TA TA or APP-TA Min.23/32-inch Glasbase;All Weather/Empire 12-inch o.c.at 4-inch lap and 24- BP-AA,SBS- SBS-AA,SBS- W-95 plywood;24-inch Base;Flexiglas Base;Flintlastic Note 2 inch o.c.in two(2),equally None AA,SBS-TA -45.0* span Base 20;Yosemite Venting Base spaced,staggered center rows or APP-TA TA or APP-TA Min.23/32-inch 12-inch o.c.at 4-inch lap and 36- BP-AA,SBS- W-96 plywood;24-inch Poly SMS Base;Ultra Poly SMS Note 2 inch o.c.in two(2),equally None AA,SBS-TA SBS-AA,SBS-APP-TA Base TA or -45.0* span spaced,staggered center rows or APP-TA FlintFast 3 in.Insulation Plates with FlintFast (Optional) Min.15/32-inch Glasbase;Plexiglas;Flintlastic Base 6-inch o.c.at 4-inch lap and 6- #12 or#14;Trufast 3"Metal Insulation Plates BP-AA,SBS- SBS-AA,SBS- W-97 plywood;24-inch 20;Poly SMS Base;Ultra Poly SMS inch o.c.in three(3),equally None -97.5 span Base;Yosemite Venting Base with DP or HD;OMG 3 in.Round Metal Plates spaced,staggered center rows AA,SBS-TA TA or APP-TA with OMG#14 HD or APP-TA Min.15/32-inch OMG 3 in.Round Metal Plates with OMG#14 6-inch o.c.at 4-inch lap and 6- W-98 plywood;24-inch Flintlastic APP Base T HD inch o.c.in three(3),equally None APP-TA APP-TA -97.5 span spaced,staggered center rows. Glasbase;Flexiglas;Flintlastic Base Min.15/32-inch FlintFast 3 in.Insulation Plates with FlintFast 8-inch o.c.at 4-inch lap and 8- (Optional) W-99 plywood;24-inch 20;All Weather/Empire Base; #14;Trufast 3"Metal Insulation Plates with inch o.c.at three(3)equally None BP-AA,SBS- SBS-AA or -97.5 span Poly SMS Base;Ultra Poly SMS Trufast HD spaced,staggered center rows AA or SBS-TA SBS-TA Base;Yosemite Venting Base NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 17 of 74 NNEMOjetc. TABLE 1F-2: DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER -MR I SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF . System Deck Base Sheet Primer Roof Cover(Note 15) MDP No. (Note 1) Base Fasteners Attach Base Ply Cap Ply (psf) Min.19/32-inch Glasbase;Flexiglas;Flintlastic Base 7-inch o.c.at 3-inch lap and 7- BP-AA,SBS- SBS-AA,SBS- W-100 plywood;24-inch 20;Poly SMS Base;Ultra Poly SMS Note 2 inch o.c.in three(3),equally None AA,SBS-TA -105.0 span Base;Yosemite Venting Base spaced,staggered center rows or APP-TA TA or APP-TA Min.19/32-inch OMG 3 in.Round Metal Plates with OMG#14 7-inch o.c.at 3-inch lap and 7- W-101 plywood;24-inch Flintlastic APP Base T HD or Dekfast Hex Plate with Dekfast#14 inch o.c.in three(3),equally None APP-TA APP-TA -105.0 span spaced,staggered center rows FlintFast 3 in.Insulation Plates with FlintFast (Optional) Min.15/32-inch Glasbase;Plexiglas;Flintlastic Base 6-inch o.c.at 4-inch lap and 6- W-102 #12 or#14;Trufast 3"Metal Insulation Plates BP-AA,SBS- SBS-AA,SBS plywood;24-inch 20;Poly SMS Base;Ultra Poly SMS inch o.c.in four(4),equally None -127.5 with DP spaced or HD;OMG 3 in.Round Metal Plates AA,SBS-TA TA or APP-TA span Base;Yosemite Venting Base with OMG#14 HD ,staggered center rows or APP-TA Min.15/32-inch OMG 3 in.Round Metal Plates with CMG#14 6-inch o.c.at 4-inch lap and 6- W-103 plywood;24-inch Flintlastic APP Base T HD inch o.c.in four(4),equally None APP-TA APP-TA -127.5 span spaced,staggered center rows. COLD-APPLIED SYSTEMS: Glasbase;Flexiglas Base;Flintlastic Min.15/32-inch Base 20;All Weather/Empire FlintFast 3 in.Insulation Plates with FlintFast 8-inch o.c.at 4-inch lap and 8- (Optional) W-104 plywood;24-inch Base;Yosemite Venting Base; #12 or#14;Trufast 3"Metal Insulation Plates inch o.c.in three(3),equally None SBS-CAI -52.5 span Flintlastic Poly SMS Base;Flintlastic with DP or HD spaced,staggered center rows SBS-CA1 Ultra Poly SMS Base TABLE IG: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OF SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System Deck Roof Cover(Note 15) Primer MDP(psf) No. (Note 1) Base Ply Ply Cap Ply W-105 APA rated,min.7/16 CAT,0.418 in.,Exposure 1,OSB FlintPrime or FlintPrime SA Flintlastic SA Mid Ply, (Optional)SBS-SA SBS-SA -90.0 sheathing;24-inch span self-adhering W-106 Min.15/32-inch plywood;24-inch span FlintPrime or FlintPrime SA SBS-SA-H (Optional)SBS-TA,APP-TA SBS-TA,APP-TA -112.5 W-107 Min.15/32-inch plywood;24-inch span FlintPrime or FlintPrime SA SBS-SA (Optional)SBS-SA SBS-SA -127.5 NEIVIO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 18 of 74 NNEMOjetc. TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Deck MDP (Notes 6,7,8) No. (Note 1) Type Fasteners Attach Type Attach Base Ply Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: HA,D-IS,M- Min.22 ga.,type B,Grade Min.2-inch ACFoam II, 1 per 4.0 Min.0.25-inch SECUROCK OSFA, S-1 33 steel or min.2,500 psi FlintBoard,ENRGY 3 or Note 2 ftZ Gypsum-Fiber Roof Board OB500,ICP SBS-SA (Optional)SBS-SA SBS-SA -37.5 structrual concrete H-Shield BOARD-MAX or CR-20 HA,D-IS,M- Min.22 ga.,type B,Grade Min.1.5-inch ACFoam OSFA, 1 per 2.0 Min.0.25-inch SECUROCK S-2 33 steel or min.2,500 psi II,FlintBoard,ENRGY 3 Note 2 ftZ Gypsum-Fiber Roof Board OB500,ICP SBS-SA (Optional)SBS-SA SBS-SA -45.0* structrual concrete or H-Shield BOARD-MAX or CR-20 HYBRID SYSTEMS: HA,D-IS,M- Min.22 ga.,type B,Grade Min.1.5-inch ACFoam OSFA, Flintlastic SBS-AA, 1 per 1.5 Additional layer(s)base (Optional)SBS-AA, S-3 33 steel or min.2,500 psi II,FlintBoard,ENRGY 3 Note 2 ftZ insulation OB500,ICP Ultra SBS-TA,APP-TA SBS-TA, -37.5 structrual concrete or H-Shield BOARD-MAX Glass SA APP-TA or CR-20 HA,D-IS,M- Min.22 ga.,type B,Grade Min.1.5-inch ACFoam ,OSFA Flintlastic SBS-AA, 1 per 1.5 Min.0.25-inch SECUROCK (Optional)SBS-AA, S-4 33 steel or min.2,500 psi II,FlintBoard,ENRGY 3 Note 2 ftZ Gypsum-Fiber Roof Board OB500,ICP Ultra SBS-TA,APP-TA SBS-TA, -52.5 structrual concrete or H-Shield BOARD-MAX Glass SA APP-TA or CR-20 Min.22 ga.,type B,Grade Min.1.5-inch ACFoam Min.1.5 inch ACFoam II HA,D-IS,M- , II,FlintBoard ISO,H- FlintFast#12 or#14 with 1 per 1.5 OSFA,M- S-5 33 steel or min.2,500 psi Shield or FlintBoard FlintFast 3"Insulation Plates ft2 FlintBoard ISO,H-Shield or PG1 or SBS-SA-H (Optional)APP-TA APP-TA -67.5 structrual concrete ISOH. FlintBoard ISOH. OB500 FlintFast#12(steel only)or#14 Min.1.5-inch ACFoam D-IS,M- Min.22 ga.,type B,Grade ti HD with FlintFast 3"Insulation II,FlintBoard ISO,H- 1 per 1.6 Min.0.25-inch SECUROCK OSFA,M- (Optional)SBS-TA SBS-TA or S-6 40 steel or min.2,500 psi Shield or FlintBoard Plates or Trufast#12(steel only) ftZ Gypsum-Fiber Roof Board PG1 or SBS-SA-H or APP-TA APP-TA -75.0 structrual concrete or HD with Trufast 3"Metal ISOH Insulation Plates OB500 FlintFast#12(steel only)or#14 Min.22 ga.,type B,Grade HD with FlintFast 3"Insulation 1 per 1.0 Min.0.5-inch SECUROCK OB500,4- (Optional)SBS-TA SBS-TA or S-7 33 steel or min.2,500 psi Min.1.5-inch ENRGY 3 Plates or Trufast#12(steel only) ftZ Gypsum-Fiber Roof Board inch o.c. SBS-SA-H or APP-TA APP-TA -90.0* structrual concrete or HD with Trufast 3"Metal Insulation Plates CONVENTIONAL SYSTEMS: NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 MEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 19 of 74 NNEMOjetc. TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Deck MDP No. (Note 1) Type Fasteners Attach Type Attach(Notes 6,7,8) Base Ply Ply Cap Ply (psf) HA,D-IS,M- BP-AA, Min.22 ga.,type B,Grade Min.2-inch ACFoam II, OSFA, (Optional)BP-AA, SBS-AA, 1 per 4.0 Min.0.25-inch SECUROCK SBS-AA, S-8 33 steel or min.2,500 psi FlintBoard,ENRGY 3 or Note 2 Z OB500,ICP SBS-AA,SBS-TA or SBS-TA or -37.5* structrual concrete H-Shield ft Gypsum-Fiber Roof Board BOARD-MAX SBS-TA or APP-TA APP-TA or CR-20 APP-TA Min.0.5-inch Structodek Min.22 ga.,type B,Grade Min.1.5-inch ACFoam High Density Fiberboard (Optional)BP-AA, SBS-AA, S-9 33 steel or min.2,500 psi II,FlintBoard,ENRGY 3 Note 2 1 pe Z2.0 Roof Insulation,min.0.75- HA BP AA or SBS-AA,SBS-TA or SBS-TA or -45.0* structrual concrete or H-Shield ft inch FescoBoard SBS AA APP-TA APP-TA (homogeneous). Min.22 a.,type B,Grade Min.1.5-inch ACFoam BP-AA, g yp (Optional)1 per 2.0 Min.0.25-inch DensDeck SBS-AA, BP-AA, SBS-AA, 5-10 33 steel or min.2,500 psi II,FlintBoard,ENRGY 3 Note 2 HA SBS-AA,SBS-TA or SBS-TA or -45.0* structrual concrete or H-Shield ftZ or DensDeck Prime SBS-TA or APP-TA APP-TA APP-TA HA,D-IS,M- BP-AA, Min.22 ga.,type B,Grade Min.1.5-inch ACFoam OSFA, (Optional)BP-AA, SBS-AA, 1 per 2.0 Min.0.25-inch SECUROCK SBS-AA, S-11 33 steel or min.2,500 psi II,FlintBoard,ENRGY 3 Note 2 Z OB500,ICP SBS-AA,SBS-TA or SBS-TA or -45.0* structrual concrete or H-Shield ft Gypsum-Fiber Roof Board BOARD-MAX SBS-TA or APP-TA APP-TA or CR-20 APP-TA Min.0.5-inch Structodek Min.22 ga.,type B,Grade Min.2-inch ACFoam II, High Density Fiberboard (Optional)BP-AA, SBS-AA, S-12 33 steel or min.2,500 psi FlintBoard,ENRGY 3 or Note 2 1 pe Z3.2 Roof Insulation,min.0.75- HA BP AA or SBS-AA,SBS-TA or SBS-TA or -45.0* structrual concrete H-Shield ft inch FescoBoard SBS-AA APP-TA APP-TA (homogeneous). Min.22 a.,t e B,Grade Min.2-inch ACFoam II, BP-AA, g yp 1 per 3.2 Min.0.25-inch DensDeck SBS-AA (Optional)BP-AA, SBS-AA, , 5-13 33 steel or min.2,500 psi FlintBoard,ENRGY 3 or Note 2 HA SBS-AA,SBS-TA or SBS-TA or -45.0* structrual concrete H-Shield ft2 or DensDeck Prime SBS-TA or APP-TA APP-TA APP-TA Min.22 ga.,type B,Grade Min.1.5-inch ACFoam 1 per 1.3 Min.0.75-inch FescoBoard BP-AA or (Optional)BP-AA, SBS-AA, S-14 33 steel or min.2,500 psi II,FlintBoard,ENRGY 3 Note 2 Z HA SBS-AA,SBS-TA or SBS-TA or -52.5 structrual concrete or Multi-Max FA3 ft (homogeneous) SBS AA APP-TA APP-TA HA,D-IS,M- BP-AA, Min.22 ga.,type B,Grade Min.2-inch ACFoam II, OSFA, (Optional)BP-AA, SBS-AA, 1 per 1.6 Min.0.25-inch SECUROCK SBS-AA, S-15 33 steel or min.2,500 psi FlintBoard,ENRGY 3 or Note 2 2 OB500,ICP SBS-AA,SBS-TA or SBS-TA or -60.0 structrual concrete H-Shield ft Gypsum-Fiber Roof Board BOARD-MAX SBS-TA or APP-TA APP-TA or CR-20 APP TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEIv1O ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 20 of 74 NNEMOletc. TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Deck MDP No. (Note 1) Type Fasteners Attach Type Attach(Notes 6,7,8) Base Ply Ply Cap Ply (psf) Min.22 ga.,type B,Grade Min.1.5-inch ACFoam (Optional)BP-AA, SBS-AA, S-16 33 steel or min.2,500 psi II,FlintBoard,ENRGY 3 Note 2 1 per 1.3 Min.Density Fiberboard HA SBS-BP-AA or SBS-AA,SBS-TA or SBS-TA or -67.5 structrual concrete or Multi-Max FA3 ft High Density Fiberboard SBS-AA APP-TA APP-TA Min.1.5-inch ACFoam FlintFast#12(steel only)or#14 D-IS,M- BP-AA, Min.22 ga.,type B,Grade HD with FlintFast 3"Insulation ft (Optional)BP-AA, SBS-AA, II,FlintBoard ISO,H- 1 per 1.6 Min.0.25-inch SECUROCK OSFA,M- SBS-AA, S-17 40 steel or min.2,500 psi Plates or Trufast#12(steel only) z SBS-AA,SBS-TA or SBS-TA or -75.0 structrual concrete Shield or FlintBoard or HD with Trufast 3"Metal Gypsum-Fiber Roof Board PG1 or SBS-TA or APP-TA APP-TA ISOH Insulation Plates OB500 APP-TA FlintFast#12(steel only)or#14 BP-AA Min.22 ga.,type B,Grade HD with FlintFast 3"Insulation (Optional)BP-AA, SBS-AA, 1 per 1.0 Min.0.5-inch SECUROCK OB500,4- SBS-AA, S-18 33 steel or min.2,500 psi Min.1.5-inch ENRGY 3 Plates or Trufast#12(steel only) ftZ Gypsum-Fiber Roof Board inch o.c. SBS-TA or SBS-AA,SBS-TA or SBS-TA or -90.0 structrual concrete or HD with Trufast 3"Metal APP-TA APP-TA Insulation Plates APP-TA COLD-APPLIED SYSTEMS: FlintFast#12(steel only)or#14 Min.2-inch ACFoam II, Min.1.5-inch ACFoam III, OB Min.22 ga.,type B,Grade HD with FlintFast 3"Insulation BO R0,ICP 1 per 2.0 FlintBoard ISO Cold,H- S-19 33 steel or min.2,500 psi FlintBoard ISO,H- Plates or Trufast#12(steel only) BOARD-MAX SBS-CA1 None SBS-CA1 45.0 ftZ Shield CG or FlintBoard ISO structrual concrete Shield or FlintBoard or HD with Trufast 3"Metal or CR-20 ISOH Insulation Plates ColdH Optional min.1.5-inch D-IS,M- FlintFast#12(steel only)or#14 O P Min.22 ga.,type B,Grade Min.2-inch ACFoam II, HD with FlintFast 3"Insulation additional layer(s)base OSFA,M- FlintBoard ISO,H- 1 per 2.0 PG1,OB500, 5-20 33 steel or min.2,500 psi Shield or FlintBoard Plates or Trufast#12(steel only) ft2 insulation,followed by ICP BOARD- SBS-CA1 None SBS-CA1 -45.0* structrual concrete or HD with Trufast 3"Metal min.0.25-inch SECUROCK ISOH Insulation Plates MAX or CR- Gypsum-Fiber Roof Board 20 Min.1.5-inch ACFoam FlintFast#12(steel only)or#14 D-IS,M- Min.22 ga.,type B,Grade HD with FlintFast 3"Insulation S-21 40 steel or min.2,500 psi II,FlintBoard ISO,H- Plates or Trufast#12(steel only) 1 per 1.6 Min.um-Finch Roof Board OSFA,M SBS-CA1 None SBS-CA1 -75.0 structrual concrete Shield or FlintBoard or HD with Trufast 3"Metal ftZ Gypsum-Fiber Roof Board PG1 or ISOH Insulation Plates OBS00 FlintFast#12(steel only)or#14 Min.22 ga.,type B,Grade HD with FlintFast 3"Insulation 1 per 1.0 Min.0.5-inch SECUROCK OB500,4- S-22 33 steel or min.2,500 psi Min.1.5-inch ENRGY 3 Plates or Trufast#12(steel only) ftZ Gypsum-Fiber Roof Board inch o.c. SBS-CA1 None SBS-CA1 -90.0 structrual concrete or HD with Trufast 3"Metal Insulation Plates NEW ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 21 of 74 ONEMOletc. BONDEDTABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPEC: MECHANICALLY ATTACHED INSULATION, .. System Deck Base Insulation Layer(s) Primer Top Insulation Layer Roof Cover(Note 15) MOP No. (Note 1) Type Fasteners Attach Base Ply Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: Min.22 ga.,type B,Grade (Optional)One or more Min.0.25-inch 1 per 5-23 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Note 2 3.2 ft 2 None SBS-SA (Optional)SBS-SA SBS-SA -30.0* structrual concrete loose laid Fiber Roof Board FlintFast#12(steel only)or Min.22 ga.,type B,Grade (Optional)One or more Min.0.25-inch #14 HD with FlintFast 3" 1 per 5-24 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Insulation Plates or Trufast#12 2.7 ft2 None SBS-SA (Optional)SBS-SA SBS-SA -37.5* structrual concrete loose laid Fiber Roof Board (steel only)or HD with Trufast 3"Metal Insulation Plates Min.22 ga.,type B,Grade (Optional)One or more Min.3/8-inch per 5-25 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Note 2 2 7 ftz None SBS-SA (Optional)SBS-SA SBS-SA -45.0* structrual concrete loose laid Fiber Roof Board Min.22 ga.,type B,Grade (Optional)One or more FlintPrime 5-26 33 steel or min.2,500 psi layers,any combination, Min.0.25-inch Note 2 1 per or SBS-SA (Optional)SBS-SA SBS-SA -45.0 structrual concrete loose laid DensDeck 1.3 ft' FlintPrime SA Min.22 ga.,type B,Grade (Optional)One or more FlintFast#14 HD with FlintFast 5-27 40 steel or min.2,500 psi layers,any combination, Min.1.5-inch 3"Insulation Plates or Trufast 1 per Z FlintPrime SBS-SA (Optional)SBS-SA SBS-SA -67.5 structrual concrete loose laid FlintBoard ISO HD with Trufast 3"Metal 1.8 ft Insulation Plates Min.22 ga.,type B,Grade (Optional)One or more Min.0.5-inch FlintFast#14 HD with FlintFast 5-28 40 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- 3"Insulation Plates or Trufast 1 per z FlintPrime SBS-SA (Optional)SBS-SA SBS-SA -82.5 structrual concrete loose laid Fiber Roof Board HD with Trufast 3"Metal 1.6 ft Insulation Plates FlintFast#15 EHD(steel only) or FlintFast#14 HD(concrete Min.22 ga.,type B,Grade (Optional)One or more Min.1.5-inch only)with FlintFast 3" FlintBoard ISO, 1 per S-29 40 steel or min.2,500 psi layers,any combination, Insulation Plates or Trufast Z FlintPrime SBS-SA (Optional)SBS-SA SBS-SA -97.5 A structrual concrete loose laid CFoa II m 11 H ISO,or H-Shield EHD(steel only)or Trufast HD 1.0 ft CFo (concrete only)with Trufast 3" Metal Insulation Plates HYBRID SYSTEMS: Min.22 ga.,type B,Grade (Optional)One or more Min.0.25-inch 1 per (Optional)BP-AA, SBS-AA, 5-30 33 steel or min.2,500 psi layers,any combination, DensDeck;DensDeck Note 2 z None SBS SA H SBS AA,SBS TA or SBS-TA or 30.0* structrual concrete loose laid Prime 2.0 ft APP-TA APP-TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NElvlo ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 22 of 74 ONEMOletc. BONDED1� P TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPEC: MECHANICALLY ATTACHED INSULATION, .. System Deck Base Insulation Layer(s) Primer Top Insulation Layer Roof Cover(Note 15) MDP No. (Note 1) Type Fasteners Attach FSBS-SA-H ase Ply Ply Cap Ply (psf) FlintFast#12(steel only)or Min.22 ga.,type B,Grade (Optional)One or more Min.0.25-inch #14 HD with FlintFast 3" 1 per (Optional)BP-AA, SBS-AA, S-31 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Insulation Plates or Trufast#12 Z None SBS-AA,SBS-TA or SBS-TA or -37.5* structrual concrete loose laid Fiber Roof Board (steel only)or HD with Trufast 2.7 ft APP-TA APP-TA 3"Metal Insulation Plates FlintFast#12(steel only)or Min.22 ga.,type B,Grade (Optional)One or more Min.3/8-inch #14 HD with FlintFast 3" 1 per (Optional)BP-AA, SBS-AA, S-32 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Insulation Plates or Trufast#12 Z None SBS-SA-H SBS-AA,SBS-TA or SBS-TA or -45.0* structrual concrete loose laid Fiber Roof Board (steel only)or HD with Trufast 2.7 ft APP-TA APP-TA 3"Metal Insulation Plates Min.22 ga.,type B,Grade (Optional)One or more FlintFast#14 HD with FlintFast S-33 40 steel or min.2,500 psi layers,any combination, Min.1.5-inch 3"Insulation Plates or Trufast 1 per z None SBS-SA-H (Optional)SBS-TA SBS-TA or -67.5 structrual concrete loose laid FlintBoard ISO HD with Trufast 3"Metal 1.8 ft or APP-TA APP-TA Insulation Plates Min.22 ga.,type B,Grade (Optional)One or more Min.1.5-inch ACFoamFlintFast#12(steel only)or SBS-AA, S-34 33 steel or min.2,500 psi layers,any combination, Il,FlintBoard ISO,H- #14 HD with FlintFast 3" 1 per None SBS-SA-H (Optional)SBS-AA, SBS-TA or -75.0 structrual concrete loose laid Shield or FlintBoard Insulation Plates 1.5 ft' SBS-TA or APP-TA APP TA ISOH. Min.22 ga.,type B,Grade (Optional)One or more Min.0.5-inch FlintFast#14 HD with FlintFast 5-35 40 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- 3"Insulation Plates or Trufast 1 per Z None SBS-SA-H (Optional)SBS-TA SBS-TA or -82.5 structrual concrete loose laid Fiber Roof Board HD with Trufast 3"Metal 1.6 ft or APP-TA APP-TA Insulation Plates FlintFast#12(steel only)or Min.22 ga.,type B,Grade (Optional)One or more Min.0.5-inch #14 HD with FlintFast 3" 1 per (Optional)SBS-TA SBS-TA or S-36 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Insulation Plates or Trufast#12 2 None SBS-SA-H -82.5 structrual concrete loose laid Fiber Roof Board (steel only)or HD with Trufast 1.5 ft or APP-TA APP-TA 3"Metal Insulation Plates 5-inch ACFoam 1. Min.22 ga.,type B,Grade (Optional)One or more Min. SBS-AA, FlintBoard ISO, 5-37 33 steel or min.2,500 psi layers,any combination, II, Note 2 1 per Z None SBS-SA-H (Optional)SBS-AA, SBS-TA or -82.5 structrual concrete loose laid FANS GY 3 or Multi-Max 1.3 ft SBS-TA or APP-TA APP-TA FlintFast#15 EHD(steel only) Min.1.5-inch or FlintFast#14 HD(concrete Min.22 ga.,type B,Grade (Optional)One or more only)with FlintFast 3" SBS-AA, FlintBoard ISO, 1 per (Optional)SBS-AA, S-38 40 steel or min.2,500 psi layers,any combination, Insulation Plates or Trufast Z None SBS-SA-H SBS-TA or -97.5 A structrual concrete loose laid ACFoam II m 11 H ISO,or H-Shield EHD(steel only)or Trufast HD 1.0 ft SBS-TA or APP-TA APP-TA ACFo (concrete only)with Trufast 3" Metal Insulation Plates NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 23 of 74 ONEMOletc. BONDED1� P TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPEC: MECHANICALLY ATTACHED INSULATION, .. System Deck Top Insulation Layer Roof Cover(Note 15) MDP Base Insulation Layer(s) Primer No. (Note 1) Type Fasteners Attach Base Ply Ply Cap Ply (psf) FlintFast#12(steel only)or Min.22 ga.,type B,Grade (Optional)One or more Min.0.5-inch #14 HD with FlintFast 3" 1 per (Optional)SBS-TA SBS-TA or S-39 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Insulation Plates or Trufast#12 1.0 ftZ None SBS or APP-TA APP-TA -135.0 structrual concrete loose laid Fiber Roof Board (steel only)or HD with Trufast 3"Metal Insulation Plates CONVENTIONAL SYSTEMS: Min.22 ga.,type B,Grade (Optional)One or more Min.0.75-inch 1 per BP-AA,SBS- (Optional)BP-AA, SBS-AA, S-40 33 steel or min.2,500 psi layers,any combination, FescoBoard Note 2 2 7 ft' None AA SBS-AA,SBS-TA or SBS-TA or -30.0* structrual concrete loose laid (homogeneous) APP-TA APP-TA Min.22 ga.,type B,Grade (Optional)One or more Min.0.5-inch (Optional)Structodek High 1 per BP-AA,SBS- BP-AA, SBS-AA, 5-41 33 steel or min.2,500 psi layers,any combination, Density Fiberboard Note 2 4.0 ftZ None AA SBS-AA,SBS-TA or SBS-TA or -37.5* structrual concrete loose laid APP-TA APP-TA Roof Insulation Min.22 ga.,type B,Grade (Optional)One or more Min.0.25-inch 1 per BP-AA,SBS- (Optional)BP-AA, SBS-AA, S-42 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Note 2 4.0 ft2 None AA SBS-AA,SBS-TA or SBS-TA or -37.5* structrual concrete loose laid Fiber Roof Board APP-TA APP-TA Min.22 ga.,type B,Grade (Optional)One or more Min.2-inch ACFoam ll, 1 per (Optional)BP-AA, SBS-AA, S-43 33 steel or min.2,500 psi layers,any combination, 1.6 ft2 Note 2 None BP-AA2 SBS-AA,SBS-TA or SBS-TA or -37.5* structrual concrete loose laid FlintBoard or ENRGY 3 APP-TA APP-TA Min.22 ga.,type B,Grade (Optional)One or more Min.0.25-inch 1 per BP-AA,SBS- (Optional)BP-AA, SBS-AA, S-44 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Note 2 4.0 ft Z None AA,SBS-TA SBS-AA,SBS-TA or SBS-TA or -45.0* structrual concrete loose laid Fiber Roof Board or APP-TA APP-TA APP-TA Min.0.5-inch Min.22 ga.,type B,Grade (Optional)One or more Structodek HighDensity Fiberboard 1 per BP-AA or (Optional)BP-AA, SBS-AA, S-45 33 steel or min.2,500 psi layers,any combination, Note 2 2 None SBS-AA,SBS-TA or SBS-TA or -45.0 structrual concrete loose laid Roof Insulation,min. 2.0 ft SBS-AA APP-TA APP-TA 0.75-inch FescoBoard (homogeneous) Min.22 ga.,type B,Grade (Optional)One or more Min.0.25-inch 1 per BP-AA,SBS- (Optional)BP-AA, SBS-AA, S-46 33 steel or min.2,500 psi layers,any combination, DensDeck or Note 2 2.0 ft2 None AA,SBS-TA SBS-AA,SBS-TA or SBS-TA or -45.0* structrual concrete loose laid DensDeck Prime or APP-TA APP-TA APP-TA Min.1-inch Min.22 ga.,type B,Grade (Optional)One or more FescoBoard (Optional)or 1 per (Optional)BP-AA, SBS-AA, S-47 33 steel or min.2,500 psi layers,any combination, Note 2 None BP-AA2 SBS-AA,SBS-TA or SBS-TA or -45.0* structrual concrete loose laid min.1.5-inch 1.6 ft APP-TA APP-TA FescoBoard (laminated) NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 24 of 74 ONEMOletc. BONDED1� P TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPEC: MECHANICALLY ATTACHED INSULATION, .. System Deck Base Insulation Layer(s) Primer Top Insulation Layer Roof Cover(Note 15) MDP No. (Note 1) Type Fasteners Attach FBP-AA2 ase Ply Ply Cap Ply (psf) Min.0.5-inch Min.22 ga.,type B,Grade (Optional)One or more Structodek, 1 per (Optional)BP-AA, SBS-AA, S-48 33 steel or min.2,500 psi layers,any combination, Structodek HD,GP HD Note 2 Z None 2.0 ft SBS-AA,SBS-TA or SBS-TA or -45.0* structrual concrete loose laid Roof Fiberboard or APP-TA APP-TA Temple HD1 or HD6 Min.22 ga.,type B,Grade (Optional)One or more Min.1.5-inch ACFoam 1 per BP-AA3,24- (Optional)BP-AA S-49 33 steel or min.2,500 psi layers,any combination, M n.Fli 1.5oard Note 2 1.5 er None inch grid or SBS-AA SBS-AA -52.5 structrual concrete loose laid Min.22 ga.,type B,Grade (Optional)One or more Min.1.5-inch ACFoam 1 per BP-AA3,24- S-50 33 steel or min.2,500 psi layers,any combination, II,FlintBoard Note 2 1.5 ft' None inch grid BP-AA or SBS-AA SBS-TA -52.5 structrual concrete loose laid Min.22 ga.,type B,Grade (Optional for Concrete orRecover)Min.1.5-inch, Min.0.25-inch FlintFast#12(steel only)or 1 per S-51 33 steel or min.2,500 psi One or more layers,any SECUROCK Gypsum- #14 HD with FlintFast 3" 1.5 per None APP-TA (Optional)APP-TA APP-TA -60.0 structrual concrete combination,loose laid Fiber Roof Board Insulation Plates (Optional for Concrete or Min.22 ga.,type B,Grade Recover)Min.2-inch Min.0.5-inch 1 per BP-AA,SBS- (Optional)BP-AA, SBS-AA, S-52 33 steel or min.2,500 psi ACFoam II,FlintBoard,H- SECUROCK Gypsum- Note 2 1.8 ft Z None AA,SBS-TA SBS-AA,SBS-TA or SBS-TA or -60.0 structrual concrete Shield or ENRGY 3,loose Fiber Roof Board or APP-TA APP-TA APP-TA laid. FlintFast#12(steel only)or Min.22 ga.,type B,Grade (Optional)One or more Min.0.5-inch #14 HD with FlintFast 3" 1 per BP-AA,SBS- (Optional)BP-AA, SBS-AA, S-53 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Insulation Plates or.Trufast#12 1.5 ft Z None AA,SBS-TA SBS-AA,SBS-TA or SBS-TA or -82.5 structrual concrete loose laid Fiber Roof Board (steel only)or HD with Trufast or APP-TA APP-TA APP-TA 3"Metal Insulation Plates Min.22 ga.,type B,Grade (Optional for Concrete or Trufast HD with Trufast 3" Recover)Min.1.5-inch Min.0.5-inch Metal Insulation Plates or 1 per BP-AA,SBS- (Optional)BP-AA, 5-54 t steel l min.2,500 psi ACFoam II,FlintBoard,H- DensDeck Prime FlintFast#14 with FlintFast 3" 1.3 ft2 None AA SBS-AA SBS-AA 112.5 structrual concrete Shield Insulation Plates FlintFast#12(steel only)or Min.22 ga.,type B,Grade (Optional)One or more Min.0.5-inch #14 HD with FlintFast 3" 1 per BP-AA,SBS- (Optional)BP-AA, SBS-AA, S-55 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Insulation Plates or.Trufast#12 1.0 ft Z None AA,SBS-TA SBS-AA,SBS-TA or SBS-TA or -135.0 structrual concrete loose laid Fiber Roof Board (steel only)or HD with Trufast or APP-TA APP-TA APP-TA 3"Metal Insulation Plates (Optional for Concrete or Trufast HD with Trufast 3" Min.22 ga.,type B,Grade Recover)Min.1.5-inch Min.SECUROCK inch Metal Insulation Plates or 1 per BP-AA,SBS- (Optional)BP-AA, 5-56 structrual steel l min.2,500 psi ACFoam II,FlintBoard,H- Fiber Roof Gypsum- FlintFast#14 with FlintFast 3" 1.3 ft2 None AA SBS-AA SBS-AA 157.5 structrual concrete Shield Fiber Roof Board Insulation Plates NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEIVIO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 25 of 74 ONEMOjetc. BONDEDTABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPEC: MECHANICALLY ATTACHED INSULATION, .. System Deck Base Insulation Layer(s) Primer Top Insulation Layer Roof Cover(Note 15) MDP No. (Note 1) Type Fasteners Attach FAA ase Ply Ply Cap Ply (psf) Min.22 ga.,type B,Grade (Optional for Concrete or Trufast HD with Trufast 3" Recover)Min.1.5-inch Min.0.5-inch Metal Insulation Plates or 1 per AA,SBS- (Optional)BP-AA, S-57 33 steel or min.2,500 psi ACFoam II,FlintBoard,H- DensDeck Prime FlintFast#14 with FlintFast 3" 1.0 ftZ None SBS AA SBS-AA -157.5 structrual concrete Shield Insulation Plates Min.22 ga.,type B,Grade (Optional for Concrete or Min.0.5-inch Trufast HD with Trufast 3" Recover)Min.1.5-inch Metal Insulation Plates or 1 per BP-AA,SBS- (Optional)BP-AA, 5-58 structrual steel l min.2,500 psi ACFoam II,FlintBoard,H- SECUROCKFiber Roof Gypsum- FlintFast#14 with FlintFast 3" 1.0 ft, None AA SBS-AA SBS-AA 172.5 structrual concrete Shield Fiber Roof Board Insulation Plates COLD-APPLIED SYSTEMS: FlintFast#12(steel only)or Min.22 ga.,type B,Grade (Optional)One or more Min.0.25-inch #14 HD with FlintFast 3" S-59 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Insulation Plates or Trufast#12 1 per 2 None SBS-CA1 None SBS-CA1 -37.5* structrual concrete loose laid Fiber Roof Board (steel only)or HD with Trufast 2.7 ft 3"Metal Insulation Plates Min.1.5-inch ACFoam FlintFast#12(steel only)or Min.22 ga.,type B,Grade (Optional)One or more III,FlintBoard Iso Cold, #14 HD with FlintFast 3" 1 per S-60 33 steel or min.2,500 psi layers,any combination, H-Shield CG or Insulation Plates or Trufast#12 2.0 ft2 None SBS-CA1 None SBS-CA1 -45.0 structrual concrete loose laid FlintBoard Iso ColdH (steel only)or HD with Trufast 3"Metal Insulation Plates FlintFast#12(steel only)or Min.22 ga.,type B,Grade (Optional)One or more Min.3/8-inch #14 HD with FlintFast 3" 1 per S-61 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Insulation Plates or Trufast#12 Z None SBS-CA1 None SBS-CA1 45.0* structrual concrete loose laid Fiber Roof Board (steel only)or HD with Trufast 2.7 ft 3"Metal Insulation Plates FlintFast#12(steel only)or Min.22 ga.,type B,Grade (Optional)One or more Min.0.5-inch #14 HD with FlintFast 3" S-62 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- Insulation Plates or Trufast#12 1 per z None SBS-CA1 None SBS-CA1 -82.5* structrual concrete loose laid Fiber Roof Board (steel only)or HD with Trufast 1.5 ft 3"Metal Insulation Plates NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 26 of 74 OONEMO etc. BONDEDTABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPED: INSULATED,MECHANICALLY ATTACHED BASE SHEET, .. System Deck Insulation Layer(s)(Note 13) Base Sheet 77 Roof Cover(Note 15) MDP No. (Note 1) Type Attach Type Fasteners Attach Base Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: Min.22 ga.,type B,Grade Min.1.5-inch,One 9-inch o.c.at min.2-inch lap and Prelim. (Optional)SBS- S-63 33 steel or min.2,500 psi or more layers,any Attached Flintlastic SA NailBase Note 2 18-inch o.c.in two(2),equally SA SBS-SA -45.0* structrual concrete combination spaced,staggered center rows Min.22 ga.,type B,Grade Min.1.5-inch,One 12-inch o.c.at min.2-inch lap and Prelim. (Optional)SBS- S-64 33 steel or min.2,500 psi or more layers,any Attached Flintlastic SA NailBase Note 2 12-inch o.c.in two(2),equally SA SBS-SA -52.5* structrual concrete combination spaced,staggered center rows Min.22 ga.,type B,Grade Min.1.5-inch,One 12-inch o.c.at min.4-inch lap and Prelim. (Optional)SBS- S-65 33 steel or min.2,500 psi or more layers,any Attached Flintlastic SA NailBase Note 2 12-inch o.c.in two(2),equally SA SBS-SA -60.0* structrual concrete combination spaced,staggered center rows Min.22 ga.,type B,Grade Min.1.5-inch,One Flintlastic SA NailBase 8-inch o.c.at min.4-inch lap and 8- Prelim. inch o.c.in two(2),equally spaced, (Optional)SBS- 5-66 33 steel or min.2,500 psi or more layers,any Attached (laid parallel to deck Note 2 staggered center rows;FlintPrime SA SBS-SA -82.5* structrual concrete combination flutes) or FlintPrime SA at plates CONVENTIONAL SYSTEMS: Glasbase;All Min.22 ga.,type B,Grade Min.1.5-inch,One Weather/Empire Base; 12-inch o.c.at 4-inch lap and 36- BP-AA,SBS-AA, Prelim. SBS-AA,SBS- S-67 33 steel or min.2,500 psi or more layers,any Flexiglas Base;Flintlastic Note 2 inch o.c.in two(2),equally spaced, SBS-TA or APP- -30.0* structrual concrete combination Attached Base 20;Yosemite staggered center rows TA TA or APP TA Venting Base Glasbase;All Min.22 ga.,type B,Grade Min.1.5-inch,One Weather/Empire Base; 12-inch o.c.at 4-inch lap and 24- BP-AA,SBS-AA, Prelim. SBS-AA,SBS- S-68 33 steel or min.2,500 psi or more layers,any Flexiglas Base;Flintlastic Note 2 inch o.c.in two(2),equally spaced, SBS-TA or APP- -45.0* structrual concrete combination Attached Base 20;Yosemite staggered center rows TA TA or APP-TA Venting Base Min.22 ga.,type B,Grade Min.1.5-inch,One 12-inch o.c.at 4-inch lap and 36- BP-AA,SBS-AA, Prelim. Poly SMS Base;Ultra Poly SBS-AA,SBS- S-69 33 steel or min.2,500 psi or more layers,any Note 2 inch o.c.in two(2),equally spaced, SBS-TA or APP- 45.0* Attached SMS Base TA or APP-TA structrual concrete combination staggered center rows TA Min.22 ga.,type B,Grade Min.1.5-inch,One Prelim. Poly SMS Base;Ultra Poly 18-inch o.c.at 4-inch lap and 18- BP-AA,SBS-AA, SBS-AA,SBS- S-70 33 steel or min.2,500 psi or more layers,any Attached SMS Base Note 2 inch o.c.in one(1)staggered SBS-TA or APP- TA or APP-TA -45.0 structrual concrete combination center row TA Min.22 ga.,type B,Grade Min.1.5-inch,One Prelim. Poly SMS Base;Ultra Poly Dekfast IF-2-SB plates with 12-inch o.c.within the min.4-inch SBS-AA,SBS-TA SBS-AA,SBS- S-71 33 steel or min.2,500 psi or more layers,any Attached SMS Base #14 Dekfast wide,heat-welded side lap or APP-TA TA or APP-TA -45.0 structrual concrete combination Glasbase;Flexiglas Base; Min.22 ga.,type B,Grade Min.1.5-inch,One Flintlastic Base 20;All 12-inch o.c.at 3-inch lap and 12- BP-AA,SBS-AA, Prelim. SBS-AA,SBS- S-72 33 steel or min.2,500 psi or more layers,any Attached Weather/Empire Base; Note 2 inch o.c.in two(2),equally spaced, SBS-TA or APP- TA or APP-TA -52.5 structrual concrete combination Poly SMS Base;Yosemite staggered center rows TA Venting Base NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 27 of 74 OONEMO etc. BONDEDTABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPED: INSULATED,MECHANICALLY ATTACHED BASE SHEET, .. System Deck Insulation Layer(s)(Note 13) Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Type Attach Type Fasteners Attach Base Ply Cap Ply (psf) Trufast 2"Barbed Metal Min.22 ga.,type B,40 ksi Min.2-inch,One or Seam Plates with Trufast Prelim. 12-inch o.c.within the min.4-inch (Optional)SBS- SBS-TA or S-73 steel or min.2,500 psi more layers,any Attached Ultra Poly SMS Base #15 EHD(steel only)or wide,heat-welded side lap TA or APP-TA APP-TA -52.5 structrual concrete combination Trufast#14 HD(concrete only) Trufast 2.4"Barbed Metal Min.22 ga.,type B,Grade Min.1.5-inch,One Seam Plates with Trufast Prelim. 12-inch o.c.within the min.4-inch (Optional)SBS- SBS-TA or S-74 80 steel or min.2,500 psi or more layers,any Attached Ultra Poly SMS Base #15 EHD(steel only)or wide,heat-welded side lap TA or APP-TA APP-TA -60.0 structrual concrete combination Trufast#14 HD(concrete only) Min.22 ga.,type B,40 ksi Min.2-inch,One or Trufast 2.4"Scoop Seam Prelim. Plates with Trufast#15 12-inch o.c.within the min.4-inch (Optional)SBS- SBS-TA or 5-75 steel or min. psi more layers,any Attached Ultra Poly SMS Base EHD(steel only)or Trufast wide,heat-welded side lap TA or APP-TA APP-TA 67.5 structrual concrete combination #14 HD(concrete only) Min.22 ga.,type B,Grade Min.1.5-inch,One Prelim. Glasbase;Yosemite OMG Flat Bottom Plates 6-inch o.c.at 4-inch lap and 6-inch BP-AA,SBS-AA, SBS-AA,SBS- S-76 33 steel or min.2,500 psi or more layers,any Attached Venting Base with OMG#14 HD o.c.in two(2),equally spaced, SBS-TA or APP- TA or APP-TA 67.5 structrual concrete combination (Accutrac) staggered center rows TA Min.22 ga.,type B,Grade Min.1.5-inch,One Flexiglas Base;Flintlastic 6-inch o.c.at 4-inch lap and 6-inch BP-AA,SBS-AA, Prelim. SBS-AA,SBS- S-77 33 steel or min.2,500 psi or more layers,any Base 20;Yosemite Note 2 o.c.in two(2),equally spaced, SBS-TA or APP- 67.5 structrual concrete combination Attached Venting Base staggered center rows TA TA or APP-TA Glasbase;Flexiglas; Flintlastic Base 20;All FlintFast 3 in.Insulation Min.22 ga.,type B,Grade Min.1.5-inch,One 6-inch o.c.at 4-inch lap and 6-inch (Optional)BP- S-78 33 steel or min.2,500 psi or more layers,any Prelim. Weather/Empire Base; Plates with FlintFast#14; O.C.at three(3)equally spaced, AA,SBS-AA or SBS-AA or -97.5 structrual concrete combination Attach Poly SMS Base;Ultra Poly Trufast 3"Metal Insulation staggered center rows SBS-TA SBS-TA SMS Base;Yosemite Plates with Trufast HD Venting Base Min.22 ga.,type B,40 ksi Min.2-inch,One or Trufast 2.4"Scoop Seam Prelim. Plates with Trufast#15 6-inch o.c.within the min.4-inch (Optional)SBS- SBS-TA or S 79 steel min. psi more layers,any Attached Ultra Poly SMS Base EHD(steel only)or Trufast wide,heat-welded side lap TA or APP-TA APP-TA 112.5 structrual concrete combination #14 HD(concrete only) Min.22 ga.,type B,Grade Min.1.5-inch,One at 4-inch lap and 12-12-inch o.c. Prelim. Poly SMS Base;Ultra Poly SBS-TA or APP- SBS-TA or S-80 80 steel or min.2,500 psi or more layers,any Attached SMS Base Note 2 inch o.c.in two(2),equally spaced, TA APP-TA -112.5 structrual concrete combination staggered center rows Min.22 ga.,type B,Grade Min.1.5-inch,One Prelim. Poly SMS Base;Ultra Poly 12-inch o.c.at 4-inch lap and 12- SBS-AA or S-81 80 steel or min.2,500 psi or more layers,any Attached SMS Base Note 2 inch o.c.in two(2),equally spaced, SBS-AA SBS-TA -120.0 structrual concrete combination staggered center rows NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEIVIO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 28 of 74 ONEMOjetc. BONDEDTABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEIVITYPED: INSULATED,MECHANICALLY ATTACHED BASE SHEET, ROOF System Deck Insulation Layer(s)(Note 13) Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Type Attach Type Fasteners Attach Base Ply Cap Ply (psf) 6-inch o.c.within the min.4-inch Min.22 ga.,type B,40 ksi Min.2-inch,One or Trufast 2.4"Scoop Seam wide,heat-welded side laps and 6- Prelim. Plates with Trufast#15 inch o.c.in one(1)center row, (Optional)SBS- SBS-TA or S 82 steel min. psi more layers,any Attached Ultra Poly SMS Base EHD(steel only)or Trufast stripped-in with 6-inch side strips TA or APP-TA APP-TA 165.0 structrual concrete combination #14 HD(concrete only) of torch-applied Poly SMS Base or Ultra Poly SMS Base. COLD-APPLIED SYSTEMS: Min.22 ga.,type B,Grade Min.1.5-inch,One Glasbase;All 6-inch o.c.at 4-inch lap and 12- Prelim. Weather/Empire Base; 5-83 33 steel or min.2,500 psi or more layers,any Attached Plexiglas Base;Flintlastic Note 2 inch o.c.in two(2),equally spaced, SBS-CA1 SBS-CAl -45.0* structrual concrete combination staggered center rows Base 20 Glasbase;Flexiglas Base; Flintlastic Base 20;All FlintFast#14 HD with Min.22 ga.,type B,Grade Min.1-inch,One or Weather/Empire Base; FlintFast 3"Insulation 6-inch o.c.at 4-inch lap and 12- (Optional)SBS- S-84 40 steel or min.2,500 psi more layers,any Loose-laid Yosemite Venting Base; Plates or Trufast HD with inch o.c.in three(3),equally CAI SBS-CA1 -75.0 structrual concrete combination Flintlastic Poly SMS Base; Trufast 3"Metal Insulation spaced,staggered center rows Flintlastic Ultra Poly SMS Plates Base NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 29 of 74 NNEMOletc. CONCRETETABLE3A: STRUCTURAL . CONSTRUCTION . BONDEDSYSTEM TYPE A-1:BONDED INSULATION, ROOF SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) M Sys. Deck primer Attach Attach Primer DP No. (Note 1) Type Type Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) SELF-ADHERING SYSTEMS: C-1. Structural FlintPrime Min.1.5-inch ACFoam II,FlintBoard, HA Min.0.25-inch SECUROCK HA None SBS-SA (Optional) SBS-SA -172.5 concrete ENRGY 3 or H-Shield Gypsum-Fiber Roof Board SBS-SA C 2 Structural FlintPrime Min.1.5-inch ACFoam Il,FlintBoard, HA Min.0.25-inch DensDeck HA FlintPrime or SBS-SA (Optional) SBS-SA -192.5 concrete ENRGY 3 or Multi-Max FA3 FlintPrime SA SBS-SA C-3. Structural None Min.1.5-inch ACFoam Il,FlintBoard, A-PD Min.0.25-inch DensDeck A-PD FlintPrime or SBS-SA (Optional) SBS-SA -105.0 concrete ENRGY 3 or Multi-Max FA3 FlintPrime SA SBS-SA C-4. Structural None Min.1.5-inch ACFoam Il,FlintBoard, A PD Min.0.25-inch SECUROCK A-PD None SBS-SA (Optional) SBS-SA -172.5 concrete ENRGY 3 or H-Shield Gypsum-Fiber Roof Board SBS-SA Structural Min.1.5-inch ACFoam II,FlintBoard, A-PD Min.0.25 inch DensDeck A-PD FlintPrime or (Optional) SBS-SA C-5. concrete None ENRGY 3 or Multi-Max FA3 6-inch o.c. 6-inch o.c. FlintPrime SA SBS-SA SBS-SA 192.5 Structural (Optional) FlintPrime or (Optional) C-6. concrete FlintPrime Min.1.5-inch Multi-Max FA D-IS Min.0.25-inch DensDeck D-IS FlintPrime SA SBS-SA SBS-SA SBS-SA 67.5 Structural (Optional) FlintPrime or (Optional) C 7. concrete FlintPrime Min.1.5-inch ENRGY 3 D-IS Min.0.25-inch DensDeck D-IS FlintPrime SA SBS-SA SBS-SA SBS-SA 112.5 Structural (Optional) FlintPrime or (Optional) C 8. concrete FlintPrime Min.1.5-inch ACFoam II or FlintBoard D-IS Min.0.25-inch DensDeck D-IS FlintPrime SA SBS-SA SBS-SA SBS-SA 120.0 C 9 Structural None Min.1.5-inch ACFoam Il,FlintBoard, D-IS Min.0.25-inch SECUROCK D-IS None SBS-SA (Optional) SBS-SA -172.5 concrete ENRGY 3 or H-Shield Gypsum-Fiber Roof Board SBS-SA (Optional)Min.1.5-inch ACFoam II, Structural M-OSFA or Min.0.5-inch ACFoam HD M-OSFA or FlintPrime or (Optional) C-10. concrete None FlintBoard ISO,H-Shield,FlintBoard M-PG1 Coverboard or H-Shield HD M-PG1 FlintPrime SA SBS-SA SBS-SA SBS-SA -97.5 ISOH Structural Min.1.5-inch ACFoam II,FlintBoard, M-OSFA or Min.0.25-inch SECUROCK M-OSFA or (Optional) C-11. concrete None ENRGY 3 or H-Shield M-PG1 Gypsum-Fiber Roof Board M-PG1 None SBS SA SBS-SA SBS SA 172.5 Structural Min.1.5-inch ACFoam Il,FlintBoard, M-OSFA or M-OSFA or FlintPrime or (Optional) C-12. concrete None ENRGY 3 or Multi-Max FA M-PG1 Min.0.25-inch DensDeck M-PG1 FlintPrime SA SBS-SA SBS-SA SBS-SA 192.5 (Optional)Min.1.5-inch ACFoam II, M-OSFA or M-OSFA or C-13. Structural None FlintBoard ISO,H-Shield,FlintBoard M-PG1,6- Min. m-Finch Roof Board M-PG1,6- FlintPrime SBS-SA (Optional) SBS-SA -315.0 concrete ISOH inch o.c. Gypsum-Fiber Roof Board inch o.c. SBS-SA (Optional)Min.1.5-inch ACFoam II, M-OSFA or M-OSFA or Structural Min.0.5-inch ACFoam HD FlintPrime or (Optional) C-14. concrete None FlintBoard ISO,H-Shield,FlintBoard M-PG3,6- Coverboard or H-Shield HD M-PG3,6- FlintPrime SA SBS-SA SBS-SA SBS-SA -315.0 ISOH inch o.c. inch o.c. C-15. Structural FlintPrime Min.1.5-inch ACFoam II,FlintBoard OB500 Min.0.25-inch DensDeck OB500 FlintPrime or SBS-SA (Optional) SBS-SA 120.0 concrete ISO or ENRGY 3 FlintPrime SA SBS-SA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 30 of 74 NNEM01letc. CONCRETETABLE3A: STRUCTURAL . CONSTRUCTION . BONDEDSYSTEM TYPE A-1:BONDED INSULATION, ROOF ir SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) Sys. Deck primer Attach Attach Primer MDP No. (Note 1) Type (Notes 6,7,8) (Notes 6,7,8)Type Base Ply Ply Cap Ply (psf) C-16. Structural None Min.1.5-inch ACFoam II,FlintBoard OB500 Min.0.25-inch DensDeck OB500 FlintPrime or SBS-SA (Optional) SBS-SA -150.0 concrete ISO or ENRGY 3 FlintPrime SA SBS-SA C-17. Structural None Min.1.5-inch ACFoam II,FlintBoard, OB500 Min.0.25-inch SECUROCK 013500 None SBS-SA (Optional) SBS-SA -172.5 concrete ENRGY 3 or H-Shield Gypsum-Fiber Roof Board SBS-SA Min.1.0-inch ISO 95+GL,H-Shield,H- ICP BOARD- ICP BOARD- Structural Shield CG,ENRGY 3 or min.1.3-inch Min.0.25-inch SECUROCK (Optional) C-18. concrete None ACFoam III,Min.1.5-inch Multi-Max MAX or CR- Gypsum-Fiber Roof Board MAX or CR- None SBS-SA SBS-SA SBS-SA 172.5 FA3 or Ultra-Max 20 20 Min.1.0-inch ISO 95+GL,H-Shield,H- ICP BOARD- ICP BOARD- Structural Shield CG,ENRGY 3 or min.1.3-inch FlintPrime or (Optional) C-19. concrete None ACFoam III,Min.1.5-inch Multi-Max MAX or CR- Min.0.25-inch DensDeck MAX or CR- FlintPrime SA SBS SA SBS-SA SBS-SA 192.5 FA3 or Ultra-Max 20 20 HYBRID SYSTEMS: Structural Min.1.5-inch ACFoam II,FlintBoard (Optional)Additional layer(s) Flintlastic (Optional) SBS-AA, C-20. concrete FlintPrime 150,H-Shield,FlintBoard ISOH HA base insulation HA None Ultra Glass SBS-AA,SBS- SBS-TA, -322.5 SA TA,APP-TA APP-TA Structural Min.1.5-inch ACFoam II,FlintBoard (Optional)Additional layer(s) Black (Optional) SBS-AA, C-21. concrete FlintPrime ISO,H-Shield,FlintBoard ISOH HA base insulation HA None Diamond SBS-AA,SBS- SBS-TA, -375.0 Base Sheet TA,APP-TA APP-TA Structural Min.1.5-inch ACFoam II,FlintBoard (Optional)Additional layer(s) (Optional) SBS-AA, C 22. concrete None ISO,H-Shield,FlintBoard ISOH A PD base insulation A-PD None SBS-SA-H SBS-AA,SBS- SBS-TA, -180.0 TA,APP-TA APP-TA Structural Min.1.5-inch ACFoam II,FlintBoard Min.0.25-inch SECUROCK (Optional) SBS-AA, C-23. concrete None ISO,H-Shield,FlintBoard ISOH A PD Gypsum-Fiber Roof Board A-PD None SBS-SA-H SBS-AA,SBS- SBS-TA, -117.5 TA,APP-TA APP-TA Structural Min.1.5-inch ACFoam II,FlintBoard A-PD,6- Min.0.25-inch SECUROCK A-PD,6- (Optional) SBS-AA, C-24. concrete None ISO,H-Shield,FlintBoard ISOH inch o.c. Gypsum-Fiber Roof Board inch o.c. None SBS-SA-H SBS-AA,SBS- SBS-TA, -217.5 TA,APP-TA APP-TA Structural Min.0.25-inch SECUROCK Gypsum- A-PD,6- (Optional) SBS-AA, C-25. concrete None Fiber Roof Board inch o.c. None N/A None SBS-SA-H SBS-AA,SBS- SBS-TA, -195.0 TA,APP-TA APP-TA Structural Min.1.5-inch ACFoam II,FlintBoard (Optional)Additional layer(s) (Optional) SBS-AA, C-26. concrete None ISO,H-Shield,FlintBoard ISOH D-IS base insulation D-IS None SBS-SA-H SBS-AA,SBS- SBS-TA, -135.0 TA,APP-TA APP-TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 31 of 74 NNEMOjetc. CONCRETETABLE3A: STRUCTURAL . CONSTRUCTION . BONDEDSYSTEM TYPE A-1:BONDED INSULATION, ROOF SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) Sys. Deck primer Primer MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) Structural Min.1.5-inch ACFoam II,FlintBoard Min.0.25-inch SECUROCK (Optional) SBS-AA, C 27. concrete None ISO,H-Shield,FlintBoard ISOH D-IS Gypsum-Fiber Roof Board D-IS None SBS-SA-H SBS-AA,SBS- SBS-TA, -217.5 TA,APP-TA APP-TA Structural Min.0.25-inch SECUROCK Gypsum- (Optional) SBS-AA, C 28. concrete None Fiber Roof Board D-IS None N/A None SBS-SA-H SBS-AA,SBS- SBS-TA, -195.0 TA,APP-TA APP-TA Structural (Optional)Min.1.5-inch ACFoam II, M-OSFA or Min.0.5-inch ACFoam HD M-OSFA or (Optional) SBS-AA, C 29. concrete None FlintBoard ISO,H-Shield,FlintBoard M-PG1 Coverboard or H-Shield HD M-PG1 None SBS-SA-H SBS-AA,SBS- SBS-TA, -97.5 ISOH TA,APP-TA APP-TA Structural Min.1.5-inch ACFoam Il,FlintBoard (Optional)Additional layer(s) (Optional) SBS-AA, C-30. concrete None ISO,H-Shield,FlintBoard ISOH M-OSFA base insulation M-OSFA None SBS-SA-H SBS-AA,SBS- SBS-TA, -232.5 TA,APP-TA APP-TA Structural Min.1.5-inch ACFoam II,FlintBoard Min.0.25-inch SECUROCK (Optional) SBS-AA, C-31. concrete None ISO,H-Shield,FlintBoard ISOH M-OSFA Gypsum-Fiber Roof Board M-OSFA None SBS-SA-H SBS-AA,SBS- SBS-TA, -217.5 TA,APP-TA APP-TA Structural Min.0.25-inch SECUROCK Gypsum- (Optional) SBS-AA, C-32. concrete None Fiber Roof Board M-OSFA None N/A None SBS-SA-H SBS-AA,SBS- SBS-TA, -195.0 TA,APP-TA APP-TA Structural Min.1.5-inch ACFoam II,FlintBoard (Optional)Additional layer(s) (Optional) SBS-AA, C-33. concrete None ISO,H-Shield,FlintBoard ISOH M-PG1 base insulation M-PG1 None SBS-SA-H SBS-AA,SBS- SBS-TA, -270.0 TA,APP-TA APP-TA Structural Min.1.5-inch ACFoam Il,FlintBoard Min.0.25-inch SECUROCK (Optional) SBS-AA, C-34. concrete None ISO,H-Shield,FlintBoard ISOH M-PG1 Gypsum-Fiber Roof Board M-PG1 None SBS-SA-H SBS-AA,SBS- SBS-TA, -217.5 TA,APP-TA APP-TA Structural Min.0.25-inch SECUROCK Gypsum- (Optional) SBS-AA, C-35. concrete None Fiber Roof Board M-PG1 None N/A None SBS-SA-H SBS-AA,SBS- SBS-TA, -195.0 TA,APP-TA APP-TA Min.0.25-inch DensDeck Structural (Optional)Min.1.5-inch ACFoam II, M-OSFA or Prime or SECUROCK Gypsum- M-OSFA or (Optional) SBS-AA, C-36. None FlintBoard ISO,H-Shield,FlintBoard M-PG1,6- Fiber Roof Board or min.0.5- M-PG1,6- None SBS-SA-H SBS-AA,SBS- SBS-TA, -315.0 concrete ISOH inch o.c. inch ACFoam HD Coverboard inch o.c. TA,APP-TA APP-TA or H-Shield HD Structural Min.1.5-inch ACFoam Il,FlintBoard (Optional)Additional layer(s) (Optional) SBS-AA, C-37. concrete None ISO,H-Shield,FlintBoard ISOH OB500 base insulation OB500 None SBS-SA-H SBS-AA,SBS- SBS-TA, -135.0 TA,APP-TA APP-TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMD ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 32 of 74 NNEMOjetc. CONCRETETABLE3A: STRUCTURAL . CONSTRUCTION . BONDEDSYSTEM TYPE A-1:BONDED INSULATION, ROOF SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) Sys. Deck primer Primer MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) Structural Min.1.5-inch ACFoam II,FlintBoard Min.0.25-inch SECUROCK (Optional) SBS-AA, C-38. concrete None ISO,H-Shield,FlintBoard ISOH OB500 Gypsum-Fiber Roof Board OB500 None SBS-SA-H SBS-AA,SBS- SBS-TA, -217.5 TA,APP-TA APP-TA Structural Min.0.25-inch SECUROCK Gypsum- (Optional) SBS-AA, C-39. concrete None Fiber Roof Board OB500 None N/A None SBS-SA-H SBS-AA,SBS- SBS-TA, -195.0 TA,APP-TA APP-TA Structural Min.1.5-inch ACFoam II,FlintBoard ICP BOARD- (Optional)Additional layer(s) ICP BOARD- (Optional) SBS-AA, C-40. concrete None ISO,H-Shield,FlintBoard ISOH MAX or CR- base insulation MAX or CR- None SBS-SA-H SBS-AA,SBS- SBS-TA, -270.0 20 20 TA,APP-TA APP-TA ICP BOARD- ICP BOARD- (Optional) SBS-AA, C-41. Structural None Min.1.5-inch ACFoam II,ISOH FlintBoard MAX or CR- Min. m-Finch Roof Board MAX or CR- None SBS-SA-H SBS-AA,SBS- SBS-TA, -217.5 concrete ISO,H-Shield,FlintBoard ISOH 20 Gypsum-Fiber Roof Board 20 TA,APP-TA APP-TA Structural Min.0.25-inch SECUROCK Gypsum- ICP BOARD- (Optional) SBS-AA, C 42. concrete None Fiber Roof Board MAX or CR- None N/A None SBS-SA-H SBS-AA,SBS- SBS-TA, -195.0 20 TA,APP-TA APP-TA CONVENTIONAL SYSTEMS: C-43. Structural FlintPrime Min.1.5-inch ACFoam II,ENRGY 3,H- HA (Optional)Additional layer(s) HA None BP-AA3,24- (Optional)BP- SBS-AA -37.5 concrete Shield,FlintBoard ISO of base insulation inch grid AA,SBS-AA C-44. Structural FlintPrime Min.1.5-inch ACFoam II or FlintBoard HA Min.0.25-inch DensDeck, HA None SBS-TA (Optional) SBS-TA -180.0 concrete ISO. DensDeck Prime SBS-TA (Optional)BP- BP-AA,SBS- SBS-AA, C-45. Structural FlintPrime (Optional)Min.1.5-inch ACFoam II or HA Min.0.25-inch SECUROCK HA None AA,SBS-TA AA,SBS AA, SBS-TA or -180.0 concrete FlintBoard ISO. Gypsum-Fiber Roof Board or APP-TA SBS-TA or APP TA APP-TA (Optional)BP- SBS-AA, Structural (Optional)Min.2-inch ACFoam II, Min.0.25-inch SECUROCK BP-AA or AA,SBS-AA, C-46. concrete FlintPrime FlintBoard ISO,ENRGY 3 or H-Shield HA Gypsum-Fiber Roof Board HA None SBS-AA SBS-TA or SBS-TA or 225.0 A APP-TA PP-TA Structural (Optional)Min.1.5-inch ACFoam II, Min.0.25-inch SECUROCK (Optional) C 47. concrete FlintPrime FlintBoard ISO,H-Shield,FlintBoard HA Gypsum-Fiber Roof Board HA None APP-TA APP TA APP-TA -252.5 ISOH (Optional)BP- SBS-AA, C-48. Structural FlintPrime Min.1.5-inch ACFoam Il,FlintBoard HA Min.0.5-inch Structodek High HA None BP-AA or AA,SBS-AA, SBS-TA or -227.0 concrete ISO,ENRGY 3 or H-Shield Density Fiberboard SBS-AA SBS-TA or APP TA APP-TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 33 of 74 NNEMOjetc. CONCRETETABLE3A: STRUCTURAL . CONSTRUCTION . BONDEDSYSTEM TYPE A-1:BONDED INSULATION, ROOF SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) Sys. Deck primer Primer MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) Structural (Optional)Min.2-inch ACFoam II, Min.0.25-inch SECUROCK SBS-TA or (Optional) SBS-TA or C-49. concrete FlintPrime FlintBoard 150,ENRGY 3 or H-Shield HA Gypsum-Fiber Roof Board HA None APP TA SBS-TA or APP TA -232.5 APP-TA (Optional)BP- SBS-AA, C-50. Structural FlintPrime Min.1.5-inch ACFoam 11,FlintBoard HA Min.0.25-inch DensDeck HA None BP-AA or AA,SBS-AA, SBS-TA or -240.0 concrete ISO,ENRGY 3 or H-Shield SBS-AA SBS-TA or App-TA APP-TA (Optional)BP- SBS-AA, C-51. Structural FlintPrime Min.1.5-inch ACFoam II or FlintBoard HA Min.0.75-inch FescoBoard HA None BP-AA or AA,SBS-AA, SBS-TA or -412.0 concrete ISO (homogeneous) SBS-AA SBS-TA or A APP-TA PP-TA (Optional)BP- SBS-AA, C-52. Structural FlintPrime Min.1.5-inch ACFoam II or FlintBoard HA Min.0.5-inch DuraBoard HA None BP-AA or AA,SBS-AA, SBS-TA or -430.0 concrete ISO (homogeneous) SBS-AA SBS-TA or APP TA APP-TA Structural 0.5-inch Structodek High Density (Optional)BP- C-53. concrete FlintPrime Fiberboard or min.0.75-inch Fesco HA None N/A None BP-AA AA or SBS-AA SBS-AA -437.5 Board(homogeneous) Structural 0.25-inch DensDeck,DensDeck Prime (Optional) SBS-AA or C-54. concrete FlintPrime or SECUROCK Gypsum-Fiber Roof HA None N/A None SBS-TA SBS-AA or SBS-TA -302.5 Board SBS-TA Flintlastic (Optional) Structural Min.0.25-inch SECUROCK Gypsum- Ultra Poly Flintlastic C-55. concrete FlintPrime Fiber Roof Board HA None N/A None SMS Base, Ultra Poly SBS-TA -487.5 torched SMS Base, torched Structural 0.25-inch DensDeck,DensDeck Prime (Optional)BP- C-56. concrete FlintPrime or SECUROCK Gypsum-Fiber Roof HA None N/A None BP-AA AA or SBS-AA SBS-AA -537.5 Board (Optional)BP- Structural Min.1.5-inch ACFoam 11,FlintBoard Min. ty0. Finch Structodek Highiberboard or Min. A PD None B SBS-TA or 105.0 BP-AA or AA,SBS-AA, SBS-AA, C-57. A-PD Density F concrete None ISO,ENRGY 3 or H-Shield SBS-AA SBS-TA or 0.25-inch DensDeck A APP-TA PP TA (Optional)BP- Structural Min.1.5-inch ACFoam 11,FlintBoard A-PD Min. ty0. Fiberboard or Min. 217.5 inch Structodek High A-PD BP-AA or AA,SBS-AA, SBS-AA,SBS-TA or C-58. concrete None ISO,ENRGY 3 or H-Shield 6-inch o.c. Density F 6-inch o.c. None SBS-AA SBS-TA or 0.25-inch DensDeck A APP-TA PP TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEIVIO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 34 of 74 NNEMOjetc. CONCRETETABLE3A: STRUCTURAL . CONSTRUCTION . BONDEDSYSTEM TYPE A-1:BONDED INSULATION, ROOF SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) Sys. Deck primer Attach Attach Primer MDP No. (Note 1) Type (Notes 6,7,8) (Notes 6,7,8)Type Base Ply Ply Cap Ply (psf) (Optional)BP- BP-AA,SBS- SBS-AA, C-59. Structural None Min.1.5-inch ACFoam II,FlintBoard A PD Min.0.25-inch SECUROCK A-PD None AA,SBS-TA AA,SBS-AA, SBS-TA or -117.5 concrete ISO,H-Shield,FlintBoard ISOH Gypsum-Fiber Roof Board or APP-TA SBS-TA or APP-TA APP-TA (Optional)BP- BP-AA,SBS- SBS-AA, Structural Min.1.5-inch ACFoam II,FlintBoard A-PD,6- Min.0.25-inch SECUROCK A-PD,6- AA,SBS-AA, C 60. concrete None ISO,H-Shield,FlintBoard ISOH inch o.c. Gypsum-Fiber Roof Board inch o.c. None AA, A SBS-TA or SBS-TA or 217.5 or APP-TP-TA A APP-TA PP-TA (Optional)BP- SBS-AA, Structural 0.5-inch Structodek High Density A-PD,6- BP-AA,SBS- AA,SBS-AA, C-61. concrete None Fiberboard inch o.c. None N/A None AA SBS-TA or SBS-TA or 195.0 A APP-TA PP-TA Min.0.25-inch DensDeck,DensDeck BP-AA,SBS- (Optional)BP- SBS-AA, C-62. Structural None Prime or SECUROCK Gypsum-Fiber A-PD,6- None N/A None AA,SBS-TA AA,SBS-AA, SBS-TA or -195.0 concrete Roof Board inch o.c. or APP-TA SBS-TA or APP-TA APP-TA C-63. Structural None Min.1.5-inch ACFoam II or FlintBoard D-IS Min.0.25-inch DensDeck D-IS None SBS-TA (Optional) SBS-TA -112.5 concrete I ISO. SBS-TA Structural Min.1.5-inch ACFoam II,FlintBoard Min.0.25-inch DensDeck BP-AA,SBS- (Optional)BP- SBS-AA or C-64. concrete None ISO,H-Shield,FlintBoard ISOH D-IS Prime D-IS None AA AA,SBS-AA or SBS-TA 297.5 SBS-TA C-65. Structural None Min.1.5-inch ACFoam II,FlintBoard D-IS Min.0.25-inch DensDeck D-IS None SBS-TA (Optional) SBS-TA -302.5 concrete ISO,H-Shield,FlintBoard ISOH Prime SBS-TA (Optional)BP- SBS-AA, C-66. Structural None Min.2-inch ACFoam II,FlintBoard ISO, D-IS Min.0.25-inch SECUROCK D-IS None BP-AA or AA,SBS-AA, SBS-TA or -225.0 concrete ENRGY 3 or H-Shield Gypsum-Fiber Roof Board SBS-AA SBS-TA or APP-TA APP-TA Structural Min.2-inch ACFoam II,FlintBoard ISO, Min.0.25-inch SECUROCK SBS-TA or (Optional) SBS-TA or C-67. concrete None ENRGY 3 or H-Shield D-IS Gypsum-Fiber Roof Board D-IS None APP TA SBS-TA or APp TA -232.5 APP-TA C-68. Structural None Min.1.5-inch ACFoam II,FlintBoard D-IS Min.0.25-inch SECUROCK D-IS None APP-TA (Optional) App-TA -252.5 concrete ISO,H-Shield,FlintBoard ISO[, Gypsum-Fiber Roof Board APP-TA Structural Min.1.5-inch ACFoam II,FlintBoard Min.0.25-inch SECUROCK BP-AA,SBS- (Optional)BP- SBS-AA or C-69. concrete None ISO,H-Shield,FlintBoard ISOH D-IS Gypsum-Fiber Roof Board D-IS None AA or SBS-TA AA,SBS-AA or SBS-TA 297.5 SBS-TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 35 of 74 NNEMOjetc. CONCRETETABLE3A: STRUCTURAL . CONSTRUCTION . BONDEDSYSTEM TYPE A-1:BONDED INSULATION, ROOF SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) Sys. Deck primer Attach Attach Primer MDP No. (Note 1) Type (Notes 6,7,8) (Notes 6,7,8)Type Base Ply Ply Cap Ply (psf) (Optional)BP- SBS-AA, Structural 0.5-inch Structodek High Density BP-AA,SBS- AA,SBS-AA, C-70. concrete None Fiberboard D-IS None N/A None AA SBS-TA or SBS-TA or 195.0 A APP-TA PP-TA (Optional)BP- BP-AA,SBS- SBS-AA, C-71. Structural None Min.0.25-inch SECUROCK Gypsum- D-IS None N/A None AA,SBS-TA AA,SBS AA, SBS-TA or -195.0 concrete Fiber Roof Board SBS-TA or or APP-TA A APP-TA PP-TA (Optional)BP- SBS-AA, C 72 Structural None Min.1.5-inch ACFoam II,FlintBoard M-OSFA Min.0.5-inch Structodek High M-OSFA None BP-AA or AA,SBS-AA, SBS-TA or -127.5 concrete ISO,ENRGY 3 or H-Shield Density Fiberboard SBS-AA SBS-TA or App-TA APP-TA (Optional)BP- SBS-AA, C-73. Structural None Min.1.5-inch ACFoam II,FlintBoard M-PG1 Min.0.5-inch Structodek High M-PG1 None BP-AA or AA,SBS-AA, SBS-TA or -180.0 concrete ISO,ENRGY 3 or H-Shield Density Fiberboard SBS-AA SBS-TA or APP-TA APP-TA (Optional)BP- SBS-AA, C-74. Structural None Min.1.5-inch ACFoam II,FlintBoard M-OSFA Min.0.25-inch DensDeck M-OSFA None BP-AA or AA,SBS-AA, SBS-TA or -232.5 concrete ISO,ENRGY 3 or H-Shield SBS-AA SBS-TA or APP-TA APP-TA (Optional)BP- SBS-AA, Structural Min.1.5-inch ACFoam II,FlintBoard BP-AA or AA,SBS-AA, C-75. concrete None ISO,ENRGY 3 or H-Shield M-PG1 Min.0.25-inch DensDeck M PG1 None SBS-AA SBS-TA or SBS-TA or 240.0 A APP-TA PP-TA Structural Min.1.5-inch ACFoam II,FlintBoard Min.0.25-inch DensDeck BP-AA,SBS- (Optional)BP- SBS-AA or C-76. concrete None ISO,H-Shield,FlintBoard ISOH M-PG1 Prime M-PG1 None AA AA,SBS-AA or SBS-TA 297.5 SBS-TA C 77 Structural None Min.1.5-inch ACFoam II,FlintBoard M-PG1 Min.0.25-inch DensDeck M-PG1 None SBS-TA (Optional) SBS-TA -302.5 concrete ISO,H-Shield,FlintBoard ISOH Prime SBS-TA (Optional)BP- SBS-AA, Structural Min.2-inch ACFoam II,FlintBoard ISO, M-OSFA or Min.0.25-inch SECUROCK M-OSFA or None BP-AA or AA,SBS-AA, 225.0 SBS-TA or C 78. concrete None ENRGY 3 or H-Shield M-PG1 Gypsum-Fiber Roof Board M-PG1 SBS-AA SBS-TA or A APP-TA PP TA Structural Min.2-inch ACFoam (Optional)II,FlintBoard ISO, M-OSFA or Min.0.25-inch SECUROCK M-OSFA or SBS-TA or SBS-TA or C 79' concrete None ENRGY 3 or H-Shield M-PG1 Gypsum-Fiber Roof Board M-PG1 None APP-TA SBS-TA or APP-TA -232.5 APP-TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 36 of 74 NNEMOjetc. CONCRETETABLE3A: STRUCTURAL . CONSTRUCTION . BONDEDSYSTEM TYPE A-1:BONDED INSULATION, ROOF mr, SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) Sys. Deck primer Attach Attach Primer MDP No. (Note 1) Type (Notes 6,7,8) (Notes 6,7,8)Type Base Ply Ply Cap Ply (psf) Structural Min.1.5-inch ACFoam II,FlintBoard M-OSFA or Min.0.25-inch SECUROCK M-OSFA or (Optional) C-80. concrete None ISO,H-Shield,FlintBoard ISOH M-PG1 Gypsum-Fiber Roof Board M-PG1 None APP-TA APP TA APP-TA 252.5 Structural Min.1.5-inch ACFoam (Optional)BP- II,FlintBoard M-OSFA or Min.0.25-inch SECUROCK M-OSFA or BP-AA,SBS- SBS-AA or C-81. concrete None ISO,H-Shield,FlintBoard ISOH M-PG1 Gypsum-Fiber Roof Board M-PG1 None AA or SBS-TA AA,SBS-AA or SBS-TA 297.5 SBS-TA (Optional)BP- SBS-AA, Structural 0.5-inch Structodek High Density BP-AA,SBS- AA,SBS-AA, C 82. concrete None Fiberboard M PG1 None N/A None AA SBS-TA or SBS-TA or 195.0 A APP-TA PP-TA (Optional)BP- BP-AA,SBS- SBS-AA, C-83. Structural None Min.0.25-inch DensDeck Prime or M-PG1 None N/A None AA,SBS-TA AA,SBS-AA, SBS-TA or -195.0 concrete SECUROCK Gypsum-Fiber Roof Board or APP-TA SBS-TA or APP-TA APP-TA (Optional)Min.1.5-inch ACFoam II, M-OSFA or Min.0.25-inch DensDeck M-OSFA or (Optional) Structural SBS-AA or SBS-AA or C-84. None FlintBoard ISO,H-Shield,FlintBoard M-PG1,6- Prime or SECUROCK Gypsum- M-PG1,6- None SBS-AA or -315.0 concrete ISOH inch o.c. Fiber Roof Board inch o.c. SBS-TA SBS-TA SBS-TA (Optional)Min.1.5-inch ACFoam II, M-OSFA or Min.0.25-inch DensDeck M-OSFA or Flintlastic C-85. Structural None FlintBoard ISO,H-Shield,FlintBoard M-PG1,6- Prime or SECUROCK Gypsum- M-PG1,6- None STA or (Optional) APP-TA -315.0 concrete ISOH inch o.c. Fiber Roof Board inch o.c. Flintlastic APP-TA STA Plus (Optional)BP- SBS-AA, C-86. Structural None Min.1.5-inch ACFoam II,FlintBoard OB500 Min.0.5-inch Structodek High OB500 None BP-AA or AA,SBS-AA, SBS-TA or -120.0 concrete ISO,ENRGY 3 or H-Shield Density Fiberboard SBS-AA SBS-TA or APP-TA APP-TA BP- (Optional)BP- Structural Min.1.5-inch ACFoam II or FlintBoard Min.0.25-inch DensDeck or AA,SBS-TA SBS- AA SBS-TA or 150.0 SBS-AA, SBS-AA, C 87. OB500 OB500 None AA,SB concrete None ISO. DensDeck Prime S-TA SBS-TA or or APP-TA A APP-TA PP TA Structural Min.1.5-inch ACFoam (Optional)BP- II,FlintBoard Min.0.25-inch DensDeck BP-AA,SBS- SBS-AA or C 88. concrete None ISO,H-Shield,FlintBoard ISOH OB500 prime OB500 None AA or SBS-TA AA,SBS-AA or SBS-TA 297.5 SBS-TA (Optional)BP- SBS-AA, C 89 Structural None Min.2-inch ACFoam II,FlintBoard ISO, OB500 Min.0.25-inch SECUROCK OB500 None BP-AA or AA,SBS-AA, SBS-TA or -225.0 concrete ENRGY 3 or H-Shield Gypsum-Fiber Roof Board SBS-AA SBS-TA or APP TA APP-TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMo ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 37 of 74 NNEMOjetc. CONCRETETABLE3A: STRUCTURAL . CONSTRUCTION . BONDEDSYSTEM TYPE A-1:BONDED INSULATION, ROOF SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) Sys. Deck primer Primer MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) Structural Min.2-inch ACFoam II,FlintBoard ISO, Min.0.25-inch SECUROCK SBS-TA or (Optional) SBS-TA or C-90. concrete None ENRGY 3 or H-Shield OB500 Gypsum-Fiber Roof Board OB500 None APP TA SBS-TA or APP TA -232.5 APP-TA C-91. Structural None Min.1.5-inch ACFoam II,FlintBoard OB500 Min.0.25-inch SECUROCK OB500 None APP-TA (Optional) App-TA -252.5 concrete ISO,H-Shield,FlintBoard ISOH Gypsum-Fiber Roof Board APP-TA Structural Min.1.5-inch ACFoam II,FlintBoard Min.0.25-inch SECUROCK BP-AA,SBS- (Optional)BP- SBS-AA or C 92. concrete None ISO,H-Shield,FlintBoard ISOH OB500 Gypsum-Fiber Roof Board OB500 None AA or SBS-TA AA,SBS-AA or SBS-TA 297.5 SBS-TA (Optional)BP- SBS-AA, Structural 0.5-inch Structodek High Density BP-AA,SBS- AA,SBS-AA, C 93. concrete None Fiberboard OB500 None N/A None AA SBS-TA or SBS-TA or 195.0 A APP-TA PP-TA (Optional)BP- BP-AA,SBS- SBS-AA, C-94. Structural None Min.0.25-inch SECUROCK Gypsum- OB500 None N/A None AA,SBS-TA AA,SBS AA, SBS-TA or -195.0 concrete Fiber Roof Board SBS-TA or or APP-TA A APP-TA PP-TA Min.1.0-inch ISO 95+GL,H-Shield,H- Min.0.5-inch Structodek High (Optional)BP- Structural Shield CG,ENRGY 3 or min.1.3-inch BP-AA or AA,SBS-AA, ICP BOARD- Density Fiberboard or ICP BOARD- SBS-AA, C-95. None MAX or CR- DuraBoard(homogeneous)or MAX or CR- None SBS-TA or -180.0 concrete ACFoam III,Min.1.5 inch Multi Max 20 min.1.5-inch FescoBoard 20 SBS AA SBS-TA or APP-TA FA3 or Ultra-Max (laminated) App TA Min.1.0-inch ISO 95+GL,H-Shield,H- (Optional)BP- ICP BOARD- ICP BOARD- SBS-AA, Structural Shield CG,ENRGY 3 or min.1.3-inch Min.0.25-inch SECUROCK BP-AA or AA,SBS-AA, C-96. concrete None ACFoam III,Min.1.5-inch Multi-Max MAX or CR- Gypsum-Fiber Roof Board MAX or CR- None SBS-AA SBS-TA or SBS-TA or 225.0 20 20 App TA FA3 or Ultra- APP-TA Min.1.0-inch ISO 95+GL,H-Shield,H- ICP BOARD- ICP BOARD- (Optional) Structural Shield CG,ENRGY 3 or min.1.3-inch Min.0.25-inch SECUROCK SBS-TA or SBS-TA or C 97. concrete None ACFoam III,Min.1.5-inch Multi-Max MAX or CR Gypsum-Fiber Roof Board MAX or CR- None APp TA SBS-TA or APp TA 232.5 FA3 or Ultra-Max 20 20 APP TA Min.1.0-inch ISO 95+GL,H-Shield,H- (Optional)BP- ICP BOARD- ICP BOARD- SBS-AA, Structural Shield CG,ENRGY 3 or min.1.3-inch BP-AA or AA,SBS-AA, C 98. concrete None ACFoam III,Min.1.5-inch Multi-Max MAX or CR- Min.0.25-inch DensDeck MAX or CR None SBS-AA SBS-TA or SBS-TA or 240.0 FA3 or Ultra-Max 20 20 APp TA APP-TA (Optional)BP- ICP BOARD- SBS-AA, Structural 0.5-inch Structodek High Density BP-AA,SBS- AA,SBS-AA, C 99' concrete None Fiberboard MAX or CR- None N/A None AA SBS-TA or SBS-TA or 195.0 20 A APP-TA PP-TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 38 of 74 NNEMOjetc. CONCRETETABLE3A: STRUCTURAL . CONSTRUCTION . BONDEDSYSTEM TYPE A-1:BONDED INSULATION, ROOF SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Base Insulation Layer Attach Top Insulation Layer Attach Primer Roof Cover(Note 15) Sys. Deck primer MDP No. (Note 1) Type (Notes 6,7,8) (Notes 6,7,8)Type Base Ply Ply Cap Ply (psf) ICP BOARD- BP-AA,SBS- (Optional)BP- SBS-AA, C-100. Structural None Min.0.25-inch SECUROCK Gypsum- MAX or CR- None N/A None AA,SBS-TA AA,SBS-AA, SBS-TA or -195.0 concrete Fiber Roof Board 20 or APP-TA SBS-TA or APP-TA APP-TA COLD-APPLIED SYSTEMS: Structural (Optional)Min.0.5-inch ACFoam II, OB500,ICP Min.1.5-inch ACFoam III, OB500,ICP C-101. None FlintBoard ISO,H-Shield,FlintBoard BOARD-MAX FlintBoard Iso Cold,H-Shield BOARD-MAX None SBS-CA1 None SBS-CA1 -82.5 concrete ISOH or CR-20 CG or FlintBoard Iso ColdH or CR-20 (Optional)Min.1.5-inch ACFoam II, Flintlastic (Optional) Structural M-OSFA or Min.0.25-inch DEXcell FA Glass M-OSFA or Poly SMS Flintlastic Poly C 102. concrete None FlintBoard ISO,H-Shield,FlintBoard None M-PG1 Mat Roof Board M-PG1 Base in SMS Base in SBS CAl 90.0 ISOH FlintBond FlintBond Structural (Optional)Min.1.5-inch ACFoam II, M-OSFA or Min.0.5-inch ACFoam HD M-OSFA or C-103. concrete None FlintBoard ISO,H-Shield,FlintBoard M-PG1 Coverboard or H-Shield HD M-PG1 None SBS-CA1 None SBS-CA1 -97.5 ISOH A-PD,D-IS, A-PD,D-IS, M-OSFA,M- M-OSFA,M- C-104. Structural None Min.0.5-inch ACFoam II,FlintBoard PG1,OB500, Min.0.25-inch SECUROCK PG1,OB500, None SBS-CA1 None SBS-CA1 -105.0 concrete ISO,H-Shield,FlintBoard ISOH ICP BOARD- Gypsum-Fiber Roof Board ICP BOARD- MAX or CR- MAX or CR- 20 20 (Optional)Min.1.5-inch ACFoam II, M-OSFA or M-OSFA or Flintlastic (Optional) Structural Min.0.25-inch DEXcell FA Glass Poly SMS Flintlastic Poly C-105. concrete None FlintBoard ISO,H-Shield,FlintBoard M-PG1,6- Mat Roof Board M-PG1,6- None Base in SMS Base in SBS-CA1 -112.5 ISOH inch o.c. inch o.c. FlintBond FlintBond (Optional)Min.1.5-inch ACFoam II, M-OSFA or Min.0.25-inch SECUROCK M-OSFA or Structural Gypsum-Fiber Roof Board or C-106. concrete None FlintBoard ISO,H-Shield,FlintBoard M-PG1,6- min.0.5-inch ACFoam HD M-PG1,6- None SBS-CAl None SBS-CAl -315.0 ISOH inch o.c. inch o.c. Coverboard or H-Shield HD NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 39 of 74 NNEMOletc. CONSTRUCTIONTABLE313: STRUCTURAL CONCRETE DECKS-NEW .. REROOF(TEAR-OFF) BONDEDSYSTEM TYPE A-3:BONDED TEMP ROOF,BONDED INSULATION, ROOF Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Deck primer TempRoof MDP sf No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (p ) (Notes 6,7,S) (Notes 6,7,8) COLD-APPLIED SYSTEMS: Structural Flintlastic SA (Optional)Min.0.5-inch ACFoam II, Min.1.5-inch ACFoam III, C-107. FlintPrime PlyBase,self- FlintBoard ISO,H-Shield,FlintBoard OB500 FlintBoard ISO Cold,H-Shield CG OB500 SBS-CA1 None SBS-CA1 -82.5 concrete adhered ISOH or FlintBoard ISO ColdH Structural Flintlastic SA Min.0.5-inch ACFoam II,FlintBoard Min.0.25-inch SECUROCK C-108. concrete FlintPrime PlyBase,self- ISO,H-Shield,FlintBoard ISOH OB500 Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -82.5 adhered TABLE 3C: STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System Deck Roof Cover(Note 15) Primer MDP(psf) No. (Note 1) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: C-109. Structural concrete FlintPrime SA SBS-SA (Optional)SBS-SA SBS-SA -555.0 C-110. Structural concrete FlintPrime SBS-SA (Optional)SBS-SA SBS-SA -630.0 HYBRID SYSTEMS: C-111. Structural concrete FlintPrime SA Flintlastic Ultra Glass SA (Optional)SBS-AA,SBS-TA,APP-TA SBS-AA,SBS-TA,APP-TA -52.5 C-112. Structural concrete FlintPrime Flintlastic Ultra Glass SA (Optional)SBS-AA SBS-AA -135.0 C-113. Structural concrete FlintPrime Black Diamond Base Sheet (Optional)SBS-TA,APP-TA SBS-TA,APP-TA -150.0 C-114. Structural concrete FlintPrime Flintlastic Ultra Glass SA (Optional)SBS-TA,APP-TA SBS-TA,APP-TA -322.5 C-115. Structural concrete FlintPrime Black Diamond Base Sheet (Optional)BP-AA,SBS-AA SBS-AA -240.0 C-116. Structural concrete FlintPrime BP-AA,SBS-AA SBS-SA-H SBS-AA,SBS-TA,APP-TA -635.0 CONVENTIONAL SYSTEMS: C-117. Structural concrete FlintPrime APP-TA (Optional)APP-TA APP-TA -420.0 C-118. Structural concrete FlintPrime SBS-TA (Optional)SBS-TA SBS-TA -542.5 C-119. Structural concrete FlintPrime BP-AA,SBS-AA (Optional)BP-AA,SBS-AA,SBS-TA or APP-TA SBS-AA,SBS-TA or APP-TA -635.0 COLD-APPLIED SYSTEMS: C-120. Structural concrete FlintPrime SBS-CA1 (Optional)SBS-CA1 SBS-CAI -262.5 NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 40 of 74 NNEMOjetc. CONCRETETABLE4A: LIGHTWEIGHT . CONSTRUCTION BONDEDSYSTEM TYPE A-1: BONDED INSULATION, ROOF System Deck LWIC Base Insulation Layer Coverboard Roof Cover(Note 15) MDP No. (Note 1) (Note 14) Type Attach Type Attach Base Ply Ply Cap Ply (psf) CELCORE(FL2037): SELF-ADHERING SYSTEMS: Min.22 ga., Min.300 psi Celcore MF One or more layer(s),min.1.5-inch Min.0.25-inch LWC-1 Type BV,Grade Cellular Concrete with thick FlintBoard ISO,FlintBoard H M-OSFA SECUROCK Gypsum- M-OSFA SBS-SA (Optional)SBS- SBS-SA -52.5 33 steel;6 ft Celcore HS Rheology ISO,ACFoam II,ACFoam III,H- Fiber Roof Board SA span Modifying Admixture Shield or H-Shield CG Min.22 ga., Min.300 psi Celcore MF One or more layer(s),min.1.5-inch Min.0.25-inch LWC-2 Type BV,Grade Cellular Concrete with thick FlintBoard ISO,FlintBoard H M-PG1 SECUROCK Gypsum- M-PG1 SBS-SA (Optional)SBS- SBS-SA -52.5 33 steel;6 ft Celcore HS Rheology ISO,ACFoam Il,ACFoam III,H- Fiber Roof Board SA span Modifying Admixture Shield or H-Shield CG Min.22 ga., Min.300 psi Celcore MF One or more layer(s),min.1.5-inch Min.0.25-inch LWC-3 Type BV,Grade Cellular Concrete with thick FlintBoard ISO,FlintBoard H OB500 SECUROCK Gypsum- OB500 SBS-SA (Optional)SBS- SBS-SA -52.5 33 steel;6 ft Celcore HS Rheology ISO,ACFoam Il,ACFoam III,H- Fiber Roof Board SA span Modifying Admixture Shield or H-Shield CG Min.22 ga., Min.300 psi Celcore MF One or more layer(s),min.1.5-inch Min.0.25-inch Type BV,Grade Cellular Concrete with thick FlintBoard ISO,FlintBoard H ICP BOARD- ICP BOARD- (Optional)SBS- LWC-4 33 steel;6 ft Celcore HS Rheology ISO,ACFoam II,ACFoam III,H- MAX SECUROCK Roof Board Gypsum- MAX SBS-SA SA SBS SA 52.5 Fiber Roof span Modifying Admixture Shield or H-Shield CG Min.22 ga., Min.300 psi Celcore MF One or more layer(s),min.1.5-inch Min.0.25-inch LWC-5 Type BV,Grade Cellular Concrete with thick FlintBoard ISO,FlintBoard H CR-20 SECUROCK Gypsum- CR-20 SBS-SA (Optional)SBS- SBS-SA -52.5 33 steel;6 ft Celcore HS Rheology ISO,ACFoam II,ACFoam III,H- Fiber Roof Board SA span Modifying Admixture Shield or H-Shield CG HYBRID SYSTEMS: M- Min.22 ga., Min.300 psi Celcore MF One or more layer(s),min.1.5-inch M-OSFA, (Optional)Min.0.25- M-OSFA,M- PG1,ICP Type BV,Grade Cellular Concrete with thick FlintBoard ISO,FlintBoard H inch SECUROCK PG1,ICP (Optional)SBS- SBS-AA, LWC-6 33 steel;6 ft Celcore HS Rheology ISO,ACFoam Il,ACFoam III,H- BOARD-MAX, Gypsum-Fiber Roof BOARD-MAX, SBS-SA-H AA,SBS-TA or SBS-TA or -52.5 span Modifying Admixture Shield or H-Shield CG ICP CR-20 or Board ICP CR-20 or APP-TA APP-TA OB500 OB500 CONVENTIONAL SYSTEMS: Min.22 ga., Min.300 psi Celcore MF One or more layer(s),min.1.5-inch Min.0.25-inch BP-AA or (Optional)BP- SBS-AA, LWC-7 Type BV,Grade Cellular Concrete with thick FlintBoard ISO,FlintBoard H M-OSFA SECUROCK Gypsum- M-OSFA SBS-AA,SBS- AA,SBS-AA,SBS- SBS-TA or -52.5 33 steel;6 ft Celcore HS Rheology ISO,ACFoam II,ACFoam III,H- Fiber Roof Board TA or APP-TA TA or APP-TA APP-TA span Modifying Admixture Shield or H-Shield CG Min.22 ga., Min.300 psi Celcore MF One or more layer(s),min.1.5-inch Min.0.25-inch BP-AA or (Optional)BP- SBS-AA, LWC-8 Type BV,Grade Cellular Concrete with thick FlintBoard ISO,FlintBoard H M-PG1 SECUROCK Gypsum- M-PG1 SBS-AA,SBS- AA,SBS-AA,SBS- SBS-TA or -52.5 33 steel;6 ft Celcore HS Rheology ISO,ACFoam II,ACFoam III,H- Fiber Roof Board TA or APP-TA TA or APP-TA APP-TA span Modifying Admixture Shield or H-Shield CG NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TR EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 41 of 74 NNEMOletc. CONCRETEIn JIM & TABLE4A: LIGHTWEIGHT . CONSTRUCTION.. . ... . BONDEDSYSTEM TYPE A-1: BONDED INSULATION, ROOF System Deck LWIC Base Insulation Layer Coverboard Roof Cover(Note 15) MDP No. (Note 1) (Note 14) Type Attach Type Attach Base Ply Ply Cap Ply (psf) Min.22 ga., Min.300 psi Celcore MF One or more layer(s),min.1.5-inch Min.0.25-inch BP-AA or (Optional)BP- SBS-AA, LWC-9 Type BV,Grade Cellular Concrete with thick FlintBoard ISO,FlintBoard H OB500 SECUROCK Gypsum- OB500 SBS-AA,SBS- AA,SBS-AA,SBS- SBS-TA or -52.5 33 steel;6 ft Celcore HS Rheology ISO,ACFoam II,ACFoam III,H- Fiber Roof Board TA or APP-TA TA or APP-TA APP-TA span Modifying Admixture Shield or H-Shield CG Min.22 ga., Min.300 psi Celcore MF One or more layer(s),min.1.5-inch Min.0.25-inch BP-AA or (Optional)BP- SBS-AA, Type BV,Grade Cellular Concrete with thick FlintBoard ISO,FlintBoard H ICP BOARD- ICP BOARD- LWC-30 33 steel;6 ft Celcore HS Rheology ISO,ACFoam II,ACFoam III,H- MAX SECUROCKFiber Roof Gypsum- MAX SBS-AA,SBS- AA,SBS-P-TAA,SBS- SBS-TA or 52.5 span Modifying Admixture Shield or H-Shield CG Fiber Roof Board TA or APP-TA TA or APP-TA APP-TA Min.22 ga., Min.300 psi Celcore MF One or more layer(s),min.1.5-inch Min.0.25-inch BP-AA or (Optional)BP- SBS-AA, LWC-11 Type BV,Grade Cellular Concrete with thick FlintBoard ISO,FlintBoard H CR-20 SECUROCK Gypsum- CR-20 SBS-AA,SBS- AA,SBS-AA,SBS- SBS-TA or -52.5 33 steel;6 ft Celcore HS Rheology ISO,ACFoam II,ACFoam III,H- Fiber Roof Board TA or APP-TA TA or APP-TA APP-TA span Modifying Admixture Shield or H-Shield CG ELASTIZELL(FL4994): COLD APPLIED SYSTEMS: Min.22 ga., Min.350 psi,min 2-inch (Optional)Additional LWC-12 Type BV,Grade Range II Elastizell with Min.1.5-inch H-Shield CG 013500,6-inch layers of base OB500,6-inch BP-CA3 or (Optional)BP- SBS-CA3 -60.0 33 steel;5 ft Zell-Crete Fibers. O.C. insulation O.C. SBS-CA3 CA3 or SBS-CA3 span Min.350 psi,min 2-inch Range II Elastizell with Zell- Min.22 ga., Crete Fibers. When (Optional)Additional Type BV,Grade walkable,attach LWC with OB layers base 500,6-inch OB500,6-inch BP-CA3 or (Optional)BP- SBS CA3 67.5 LWC-13 33 steel;5 ft FlintFast#14 and FlintFast Min.1.5-inch H-Shield CG O.C. insulation O.C. SBS-CA3 CA3 or SBS-CA3 span 3"Round Plates at 1 per 8 ftz through to the structural deck. NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 42 of 74 OONEMO etc. BONDEDTABLE4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF, SYSTEM TYPE A-1: BONDED INSULATION, ROOF Base Insulation Layer Coverboard Roof Cover(Note 15) System Deck LWIC MDP No. (Note 1) (Note 14) Type Attach(Notes 6,7,8) Type Attach(Notes 6,7,8) Primer Base Ply Ply Cap Ply (psf) CELCORE(FL2037): SELF-ADHERING SYSTEMI Min.300 psi Celcore MF Cellular Concrete One or more layer(s),min.1.5-inch Min.0.25-inch LWC-14 Structural with Celcore HS thick ACFoam 11, ISO,am III,H- H M-OSFA SECUROCK Gypsum-Fiber M-OSFA None SBS-SA (Optional) SBS-SA -172.5 concrete ISO,ACFoam II,ACFoam III,H- SBS-SA Rheology Modifying Shield or H-Shield CG Roof Board Admixture Min.300 psi Celcore One or more layer(s),min.1.5-inch Structural MF Cellular Concrete thick FlintBoard ISO,FlintBoard H Min.0.25-inch (Optional) LWC-15 concrete With Celcore HS ISO,ACFoam II,ACFoam III,H- M-PG1 SECUROCK Gypsum-Fiber M-PG1 None SBS-SA SBS-SA SBS-SA -172.5 Rheology Modifying Shield or H-Shield CG Roof Board Admixture Min.300 psi Celcore One or more layer(s),min.1.5-inch Structural MF Cellular Concrete thick FlintBoard ISO,FlintBoard H Min.0.25-inch (Optional) LWC-16 concrete With Celcore HS ISO,ACFoam II,ACFoam III,H- OB500 SECUROCK Gypsum-Fiber OB500 None SBS-SA SBS-SA SBS-SA -172.5 Rheology Modifying Shield or H-Shield CG Roof Board Admixture Min.1.0-inch ISO 95+GL,H-Shield, Structural Min.200 psi,min.2- H-Shield CG,ENRGY 3 or min.1.3- Min.0.25-inch (Optional) LWC-17 inch Celcore Cellular CR-20 SECUROCK Gypsum-Fiber CR-20 None SBS-SA SBS-SA -172.5 concrete Concrete inch ACFoam III,Min.1.5-inch Roof Board SBS-SA Multi-Max FA3 or Ultra-Max Min.300 psi Celcore One or more layer(s),min.1.5-inch Structural MF Cellular Concrete thick FlintBoard ISO,FlintBoard H Min.0.25-inch (Optional) LWC-18 concrete With Celcore HS ISO,ACFoam II,ACFoam III,H- CR-20 SECUROCK Gypsum-Fiber CR-20 None SBS-SA SBS-SA SBS-SA -172.5 Rheology Modifying Shield or H-Shield CG Roof Board Admixture Min.1.0-inch ISO 95+GL,H-Shield, FlintPrime Structural Min. e psi,min.2- H-Shield CG,ENRGY 3 or min.1.3- or (Optional) LWC-19 inch Celcore Cellular CR-20 Min.0.25-inch DensDeck CR-20 SBS-SA SBS-SA -180.0 concrete Concrete inch ACFoam III,Min.1.5-inch FlintPrime SBS-SA Multi-Max FA3 or Ultra-Max SA Min.300 psi Celcore M-OSFA,M- M-OSFA,M One or more layer(s),min.1.5-inch SBS-AA, MF Cellular Concrete PG1,ICP (Optional)Min.0.25-inch PG1,ICP (Optional) LWC-20 Structural with Celcore HS thick ACFoam 11, ISO,am III,H- H BOARD-MAX, SECUROCK Gypsum-Fiber BOARD-MAX, None SBS-SA-H SBS-AA,SBS- or APP -215.0 concrete ISO,ACFoam II,ACFoam III,H- or APP- Rheology Modifying ICP CR-20 or Roof Board ICP CR-20 or TA or APP-TA Admixture Shield or H-Shield CG OB500 OB500 TA CONVENTIONAL SYSTEMS: NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEIVIO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 43 of 74 OONEMO etc. BONDEDTABLE4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF, SYSTEM TYPE A-1: BONDED INSULATION, ROOF Base Insulation Layer Coverboard Roof Cover(Note 15) System Deck LWIC MDP (Notes 6,7,8) No. (Note 1) (Note 14) Type Attach Type Attach(Notes 6,7,8) Primer Base Ply Ply Cap Ply (psf) Min.300 psi Celcore One or more layer(s),min.1.5-inch BP-AA, (Optional) SBS-AA,.0.25-inch MF Cellular Concrete Min Structural thick FlintBoard ISO,FlintBoard H SBS-AA, BP-AA,SBS- SBS-TA LWC-21 concrete With Celcore HS ISO,ACFoam II,ACFoam III,H- M-OSFA SECUROCK Gypsum-Fiber M-OSFA None SBS-TA or AA,SBS-TA or APP- -215.0 Rheology Modifying Shield or H-Shield CG Roof Board APP-TA or APP-TA TA Admixture Min.300 psi Celcore One or more layer(s),min.1.5-inch BP-AA, (Optional) SBS-AA, MF Cellular Concrete Min.0.25-inch Structural thick FlintBoard ISO,FlintBoard H SBS-AA, BP-AA,SBS- SBS-TA LWC-22 concrete With Celcore HS ISO,ACFoam II,ACFoam III,H- M-PG1 SECUROCK Gypsum-Fiber M-PG1 None SBS-TA or AA,SBS-TA or APP- -215.0 Rheology Modifying Shield or H-Shield CG Roof Board APP-TA or APP-TA TA Admixture Min.300 psi Celcore One or more layer(s),min.1.5-inch BP-AA, (Optional) SBS-AA, Structural MF Cellular Concrete thick FlintBoard ISO,FlintBoard H Min.0.25-inch SBS-AA, BP-AA,SBS- SBS-TA LWC-23 concrete With Celcore HS ISO,ACFoam II,ACFoam III,H- OB500 SECUROCK Gypsum-Fiber OB500 None SBS-TA or AA,SBS-TA or APP- -215.0 Rheology Modifying Shield or H-Shield CG Roof Board APP-TA or APP-TA TA Admixture Min.300 psi Celcore One or more layer(s),min.1.5-inch BP-AA, (Optional) SBS-AA, MF Cellular Concrete Min.0.25-inch Structural thick FlintBoard ISO,FlintBoard H ICP BOARD- ICP BOARD- SBS-AA, BP-AA,SBS- SBS-TA LWC-24 concrete With Celcore HS ISO,ACFoam II,ACFoam III,H- MAX SECUROCK Gypsum-Fiber MAX None SBS-TA or AA,SBS-TA or APP- -215.0 Rheology Modifying Shield or H-Shield CG Roof Board APP-TA or APP-TA TA Admixture Min.0.5-inch Structodek Min.200 psi,min.2- Min.1.0-inch ISO 95+GL,H-Shield, High Density Fiberboard (Optional) SBS-AA, Structural H-Shield CG,ENRGY 3 or min.1.3 CR-20 CR-20 None or DuraBoard BP-AA or BP-AA,SBS- SBS-TA 180.0 LWC-25 concrete inch Celcore Cellular inch ACFoam III,Min.1.5-inch (homogeneous)or min. SBS-AA AA,SBS-TA or APP- Concrete Multi-Max FA3 or Ultra-Max 1.5-inch FescoBoard or APP-TA TA (laminated) 2-min 200 psi, , . Min.1.0-inch ISO 95+GL,H-Shield, Min.0.25-inch BP-AA,SBS- (Optional) SBS-AA, Structural H-Shield CG,ENRGY 3 or min.1.3 CR-20 SECUROCK Gypsum-Fiber or APP-TA BP-AA,SBS- SBS-TA 180.0 LWC-26 concrete inch Celcore Cellular inch ACFoam III,Min.1.5-inch Roof Board or DensDeck CR-20 None AA,SBS-TA AA,SBS-TA or APP- Multi-Max Multi-Max FA3 or Ultra-Max or DensDeck Prime or APP-TA TA Min.300 psi Celcore One or more layer(s),min.1.5-inch BP-AA, (Optional) SBS-AA, MF Cellular Concrete Min.0.25-inch Structural thick FlintBoard ISO,FlintBoard H SBS-AA, BP-AA,SBS- SBS-TA LWC-27 concrete With Celcore HS ISO,ACFoam II,ACFoam III,H- CR-20 SECUROCK Gypsum-Fiber CR-20 None SBS-TA or AA,SBS-TA or APP- -215.0 Rheology Modifying Shield or H-Shield CG Roof Board APP-TA or APP-TA TA Admixture ELASTIZELL(FL4994): SELF-ADHERING SYSTEMS: NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMo ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 44 of 74 OONEMO etc. BONDEDTABLE4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF, SYSTEM TYPE A-1: BONDED INSULATION, ROOF Base Insulation Layer Coverboard Roof Cover(Note 15) System Deck LWIC MDP No. (Note 1) (Note 14) Type Attach(Notes 6,7,8) Type Attach(Notes 6,7,8) Primer Base Ply Ply Cap Ply (psf) 25-inch 0. Structural Min.200 psi,min.2- Min.1.5-inch ACFoam II, A-PD,6-inch Min. A-PD,6-inch (Optional) LWC-28 concrete inch Elastizell FlintBoard,ENRGY 3 or H-Shield O.C. SECUROCK Gypsum-Fiber O.C. None SBS-SA SBS-SA SBS-SA -172.5 Roof Board Min.1.5-inch ACFoam II, FlintPrime LWC-29 Structural Min.200 psi,min.2- FlintBoard,ENRGY 3 or Multi-Max A-PD,6-inch Min.0.25-inch DensDeck A-PD,6-inch or SBS-SA (Optional) SBS-SA -187.5 concrete inch Elastizell FA3 O.C. O.C. FlintPrime SBS-SA SA FlintPrime Structural Min.200 psi,min.2- Min.1.5-inch ACFoam II,FlintBoard or (Optional) LWC-30 concrete inch Elastizell ISO or ENRGY 3 OB500 Min.0.25 inch DensDeck 0B500 FlintPrime SBS SA SBS-SA SBS SA 150.0 SA Structural Min.200 psi,min.2- Min.1.5-inch ACFoam II, Min.0.25-inch (Optional) LWC-31 concrete inch Elastizell FlintBoard,ENRGY 3 or H-Shield OB500 SECUROCK Gypsum-Fiber OB500 None SBS-SA SBS-SA SBS-SA -172.5 Roof Board Min.1.0-inch ISO 95+GL,H-Shield, Structural Min.200 psi,min.2- H-Shield CG,ENRGY 3 or min.1.3- Min. inch LWC-32 CR-20 ROC (Optional) SBS-SA concrete inch Elastizell inch ACFoam III,Min.1.5-inch Roof Boa SECUROCK Gypsum-Fiber CR-20 None SBS-SA SBS-SA 172.5 R Multi-Max FA3 or Ultra-Max Roof Board Min.1.0-inch ISO 95+GL,H-Shield, FlintPrime Structural Min.200 psi,min.2- H-Shield CG,ENRGY 3 or min.1.3- or (Optional) LWC 33 concrete inch Elastizell inch ACFoam III,Min.1.5-inch CR-20 Min.0.25 inch DensDeck CR 20 FlintPrime SBS SA SBS-SA SBS-SA 180.0 Multi-Max FA3 or Ultra-Max SA CONVENTIONAL SYSTEMS: or Min.0.5-inch Structodek (Optional) SBS-AA, Structural Min.200 psi,min.2- Min.1.5-inch ACFoam II,FlintBoard A-PD High Density Fiberboard A-PD BP-AA or BP-AA,SBS- SBS-TA LWC-34 concrete inch Elastizell ISO,ENRGY 3 or H-Shield 6-inch o.c. or Min.0.25-inch 6-inch o.c. None SBS-AA AA,SBS-TA or APP- 187.5 DensDeck or APP-TA TA Min.0.25-inch BP-AA or (Optional) SBS-AA, LWC-35 Structural Min.200 psi,min.2- Min.1.5-inch ACFoam II,FlintBoard A-PD,6-inch SECUROCK Gypsum-Fiber A-PD,6-inch None SBS-AA, BP-AA,SBS- SBS-TA -217.5 concrete inch Elastizell ISO,ENRGY 3 or H-Shield O.C. Roof Board O.C. SBS-TA or AA,SBS-TA or APP- APP-TA or APP-TA TA BP-AA,SBS- (Optional) SBS-AA, Structural Min.200 psi,min.2- Min.1.5-inch ACFoam II or Min.0.25-inch DensDeck BP-AA,SBS- SBS-TA LWC-36 concrete inch Elastizell FlintBoard ISO. OB500 or DensDeck Prime OB500 None AA,SBS-TA AA SBS-TA or APP- 150.0 or APP-TA or APP-TA TA Min.0.25-inch LWC-37 Structural Min. psi,min.2- Min.1.5-inch ACFoam II or OB500 SECUROCK Gypsum-Fiber OB500 None SBS-TA (Optional) SBS-TA -180.0 Roof Board concrete inch Elastizell FlintBoard ISO. SBS-TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEIVIO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 45 of 74 OONEMO etc. BONDEDTABLE4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF, SYSTEM TYPE A-1: BONDED INSULATION, ROOF Base Insulation Layer Coverboard Roof Cover(Note 15) System Deck LWIC MDP No. (Note 1) (Note 14) Type Attach(Notes 6,7,8) Type Attach(Notes 6,7,8) Primer Base Ply Ply Cap Ply (psf) Min.0.25-inch BP-AA, (Optional) SBS-AA, Structural Min.200 psi,min.2- Min.2-inch ACFoam II,FlintBoard OB500 SBS-AA, BP-AA,SBS- SBS-TA 225.0 LWC-38 concrete inch Elastizell ISO,ENRGY 3 or H-Shield Roof Board Gypsum-Fiber OB500 None SBS-TA or AA,SBS-TA or APP- Roof Boar APP-TA or APP-TA TA Min.0.5-inch Structodek Min.1.0-inch ISO 95+GL,H-Shield, High Density Fiberboard (Optional) SBS-AA, Structural Min.200 psi,min.2- H-Shield CG,ENRGY 3 or min.1.3- CR-20 or DuraBoard CR-20 None BP-AA or BP-AA,SBS- SBS-TA 180.0 LWC-39 concrete inch Elastizell inch ACFoam III,Min.1.5-inch (homogeneous)or min. SBS-AA AA,SBS-TA or APP- Multi-Max FA3 or Ultra-Max 1.5-inch FescoBoard or APP-TA TA (laminated) Min.1.0-inch ISO 95+GL,H-Shield, Min.0.25-inch BP-AA,SBS- (Optional) SBS-AA, CR-20 Structural Min.200 psi,min.2- H-Shield CG,ENRGY 3 or min.1.3- SECUROCK Gypsum-Fiber BP-AA,SBS- SBS-TA LWC-40 concrete inch Elastizell inch ACFoam III,Min.1.5-inch Roof Board or DensDeck CR-20 None AA,SBS-TA AA SBS-TA or APP- 180.0 or APP-TA Multi-Max FA3 or Ultra-Max or DensDeck Prime or APP-TA TA COLD APPLIED SYSTEMS: IL Structural Min.350 psi,min 2- OB500,6-inch (Optional)Additional OB500,6-inch BP-CA3 or (Optional) LWC-41 concrete inch Elastizell with Min.1.5-inch H-Shield CG O.C. layers of base insulation O.C. None SBS-CA3 BP-CA3 or SBS-CA3 -60.0 Zell-Crete Fibers. SBS-CA3 Min.350 psi,min 2-inch Range II Elastizell with Zell-Crete Fibers. When (Optional) Structural walkable,attach LWC OB500,6-inch (Optional)Additional OB500,6-inch None BP-CA3 or 67.5 BP-CA3 or SBS-CA3 LWC-42 concrete with FlintFast#14 and Min.1.5-inch H-Shield CG O.C. layers of base insulation O.C. SBS-CA3 FlintFast 3"Round Plates SBS-CA3 at 1 per 8 ftz through to the structural deck. NEIVIO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 46 of 74 NNEMOletc. TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION.. REROOF(TEAR-OFF) SYSTEMTYPEA-1: LWCTO DECK,BONDED VAPOR BARRIER,BONDED INSULATION,BONDED ROOF COVER Base Insulation Layer Coverboard Roof Cover(Note 15) System Deck LWIC Primer Attach Attach MDP No. (Note 1) (Note 14) Vapor Barrier Type (Notes Type (Notes Base Ply Ply Cap Ply (psf) 6&7) 6&7) PRE-EXISTENT CELLULAR LWC: SELF-ADHERING SYSTEMS: Flintlastic Ultra Poly SMS Base Sheet Min.40c psi,Min.2- applied in Millennium Hurricane Force One or more layers, (Optional)ck inch thick,existing(> Y Min.22 Membrane Adhesive HS,ribbons max. in.DensDeck FlintPrime 28 days old)cellular min.2-in.ACFoam ga.,Type 6-inch o.c. 3-inch wide side laps and 6- M-OSFA Prime or M-OSFA or (Optional) LWC 43 BV,Grade lightweight concrete; inch wide end laps are hot-air-welded, II,FlintBoard ISO,H or M-PG1 SECUROCK or M-PG1 FlintPrime SBS SA SBS-SA SBS-SA 67.5 Repair LWC(palls with torch-welded or sealed with Millennium Shield or FlintBoard 40 steel Celcore SBS(Sanded Gypsum-Fiber SA Hurricane Force Lap and Flashing H ISO Bonding Surface) Roof Board Adhesive HYBRID SYSTEMS: Flintlastic Ultra Poly SMS Base Sheet Min.40c psi,Min.2- applied in Millennium Hurricane Force Dens. inch thick,existing(> pp One or more layers, Min.22 Membrane Adhesive HS,ribbons max. DensDeck 28 days old)cellular min.2-in.ACFoam (Optional) SBS-TA ga.,Type 6-inch o.c. 3-inch wide side laps and 6- M-OSFA Prime or M-OSFA (Optional) LWC-44 lightweight concrete; II,FlintBoard ISO,H- SBS-SA-H SBS-TA or or APP- -67.5 BV,Grade inch wide end laps are hot-air-welded, or M-PG1 SECUROCK or M-PG1 FlintPrime Repair LWC(palls with torch-welded or sealed with Millennium Shield or FlintBoard APP-TA TA 40 steel Celcore 5B5(Sanded Gypsum-Fiber Hurricane Force Lap and Flashing H ISO Bonding Surface) Roof Board Adhesive CONVENTIONAL SYSTEMS: Min.400 psi,Min.2- Flintlastic Ultra Poly SMS Base Sheet 0.5-in. applied in Millennium Hurricane Force One or more layers,inch thick,existing(> Y Min.22 , DensDeck Membrane Adhesive HS ribbons max. 28 days old)cellular min.2-in.ACFoam (Optional) SBS-TA ga.,Type 6-inch o.c. 3-inch wide side laps and 6- M-OSFA Prime or M-OSFA (Optional) SBS-TA or LWC-45 lightweight concrete; II,FlintBoard ISO,H- SBS-TA or or APP- -67.5 BV,Grade inch wide end laps are hot-air-welded, or M-PG1 SECUROCK or M-PG1 FlintPrime APP-TA Repair LWC(palls with torch-welded or sealed with Millennium Shield or FlintBoard or TA 40 steel Celcore SBS(Sanded H ISO Gypsum-Fiber Bonding Surface) Hurricane Force Lap and Flashing Roof Board Adhesive ELAST¢ELL(FL4994): SELF-ADHERING SYSTEMS: All Weather/Empire Base Sheet (Optional)0.5- applied in Millennium Hurricane Force One or more layers, in.DensDeck FlintPrime Membrane Adhesive,ribbons max.6- min.2-in.ACFoam Structural Min.420 psi,min. M-OSFA Prime or M-OSFA or (Optional) LWC-46 inch o.c.; 3-inch wide side laps and 6- II,FlintBoard ISO,H- SBS-SA SBS-SA -67.5 Concrete 2-inch Elastizell inch wide end laps are sealed with Shield or FlintBoard or M-PG1 SECUROCK or M-PG1 FlintPrime SBS-SA Millennium Hurricane Force Lap and H ISO Gypsum-Fiber SA Flashing Adhesive Roof Board NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 MEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 47 of 74 NNEMOletc. TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION.. REROOF(TEAR-OFF) SYSTEMTYPEA-1: LWCTO DECK,BONDED VAPOR BARRIER,BONDED INSULATION,BONDED ROOF COVER Base Insulation Layer Coverboard Roof Cover(Note 15) System Deck LWIC Attach Attach MDP Vapor Barrier Primer No. (Note 1) (Note 14) Type (Notes Type (Notes Base Ply Ply Cap Ply (psf) 6&7) 6&7) Flintlastic Ultra Poly SMS Base Sheet (Optional)0.5- applied in Millennium Hurricane Force One or more layers, Membrane Adhesive,ribbons max.6- min.2-in.ACFoam in.DensDeck FlintPrime Structural Min.420 psi,min. inch o.c.; 3-inch wide side laps and 6- M-OSFA Prime or M-OSFA or (Optional) LWC 47 Concrete 2-inch Elastizell inch wide end laps are hot-air-welded, II,FlintBoard ISO,H or M-PG1 SECUROCK or M-PG1 FlintPrime SBS SA SBS-SA SBS-SA 67.5 torch-welded or sealed with Millennium Shield or FlintBoard H ISO Gypsum-Fiber SA Hurricane Force Lap and Flashing Roof Board Adhesive HYBRID SYSTEMS: All Weather/Empire Base Sheet 0.5-in. applied in Millennium Hurricane Force One or more layers, DensDeck Structural Min.420 psi,min Membrane Adhesive,ribbons max.6- min.2-in.ACFoam M-OSFA Prime or M-OSFA (Optional) (Optional) SBS-TA . LWC-48 inch o.c.; 3-inch wide side laps and 6- II,FlintBoard ISO,H- SBS-SA-H SBS-TA or or APP- -67.5 Concrete 2-inch Elastizell inch wide end laps are sealed with Shield or FlintBoard or M-PG1 SECUROCK or M-PG1 FlintPrime APP-TA TA Millennium Hurricane Force Lap and H ISO Gypsum-Fiber Flashing Adhesive Roof Board Flintlastic Ultra Poly SMS Base Sheet 0.5-in. applied in Millennium Hurricane Force One or more layers, Membrane Adhesive,ribbons max.6- DensDeck min.2-in.ACFoam (Optional) SBS-TA Structural Min.420 psi,min. inch o.c.; 3-inch wide side laps and 6- M-OSFA Prime or M-OSFA (Optional) LWC-49 Concrete 2-inch Elastizell inch wide end laps are hot-air-welded, II,field o Flinard ISO,H or M-PG1 SECUROCK or M-PG1 FlintPrime SBS-SA-H SBS-TA or or APP- 67.5 torch-welded or sealed with Millennium Shield or FlintBoard APP-TA TA H ISO Gypsum-Fiber Hurricane Force Lap and Flashing Roof Board Adhesive CONVENTIONAL SYSTEMS: All Weather/Empire Base Sheet 0.5-in. applied in Millennium Hurricane Force One or more layers, DensDeck Structural Min.420 psi,min Membrane Adhesive,ribbons max.6- min.2-In.ACFoam M-OSFA Prime or M-OSFA (Optional) SBS-TA or (Optional) SBS-TA . LWC-50 Concrete 2-inch Elastizell or M-PG1 SECUROCK or M-PG1 FlintPrime APP-TA inch o.c.; 3-inch wide side laps and 6- II,FlintBoard ISO,H- SBS-TA or or APP- -67.5 inch wide end laps are sealed with Shield or FlintBoard APP-TA TA Millennium Hurricane Force Lap and H ISO Gypsum-Fiber Flashing Adhesive Roof Board Flintlastic Ultra Poly SMS Base Sheet applied in Millennium Hurricane Force One or more layers, 0.5-in. Membrane Adhesive,ribbons max.6- DensDeck min.2-in.ACFoam (Optional) SBS TA Structural Min.420 psi,min. inch o.c.; 3-inch wide side laps and 6- M-OSFA Prime or M-OSFA (Optional) SBS-TA or LWC 51 Concrete 2-inch Elastizell inch wide end laps are hot-air-welded, II,field o Flinard ISO,H or M-PG1 SECUROCK or M-PG1 FlintPrime APP-TA SBS-TA or or APP- 67.5 torch-welded or sealed with Millennium Shield or FlintBoard APP-TA TA H ISO Gypsum-Fiber Hurricane Force Lap and Flashing Roof Board Adhesive NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 48 of 74 CONCRETETABLE 4D: LIGHTWEIGHT •VER STEEL DECKS—NEW • •N or R•• • OONEMO etc. SYSTEM TYPE A-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER LWIC(Note 14) Anchor Sheet Insulation Roof Cover(Note 15) System Deck MOP Treatment No. (Note 1) Deck Type Surface Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply (psf) PRE-EXISTENT CELLULAR LWC: CONVENTIONAL SYSTEMS: 9-inch o.c.at the 4-inch side lap Min.2 ga. Min 350 psi, and 9-inch o.c.at steel orr Min.1.5- BP-AA4, (Optional) Mill 2-inch pre- Yosemite Venting Trufast Twin- two,equally (Optional)Additional Hot structural None None inch 18-inch BP-AA,SBS- SBS-AA -60.0 LWC-52 concrete existent Base Loc Nails spaced, ACFoam II layers base insulation asphalt O.C. AA deck. cellular LWIC staggered rows in the center of the sheet Note: To qualify the LWIC under this assembly,the subject fastenershall achieve on average withdrawal of 88lbf when tested perANSI/SPRI FX-1 or TA5105. CELCORE(FL2037): SELF-ADHERING SYSTEMS: Min.470 psi, All (Optional)Min.0.25- min.2-inch 7-inch o.c.at the Weather/Empire inch DensDeck Prime Min.22 ga., Celcore MF min.4-inch side Min.1.5" Base Sheet, Trufast FM- or SECUROCK type BV, Celcore 5-1 Cellular Celcore PVA laps and 7-inch FlintBoard Plexiglas Base, 90 Base Gypsum-Fiber Roof Hot (Optional) LWC-53 Grade 40 Deck Concrete with Curing o.c.at two, ISO or SBA-SA SBS-SA -60.0 Sheet,Yosemite Fasteners steel;6 ft Preparation Celcore HS Compound Glasbase Base Sheet equally spaced, FlintBoard Board. Top surface asphalt SBS-SA span Rheology staggered center I50-T shall primed with Modifying Venting Base or rows FlintPrime or Admixture Flintlastic Base 20 FlintPrime SA. HYBRID SYSTEMS: (Optional)Min. Min.470 psi, All 0.125-inch STURDY- min.2-inch 7-inch o.c.at the DEK Asphaltic Cover Min.22 ga., Celcore MF Weather/Empire min.4-inch side Min.1.5" Board or min.0.25- Base Sheet, Trufast FM- (Optional) SBS-AA, type BV, Celcore S-1 Cellular Celcore PVA laps and 7-inch FlintBoard inch DensDeck Prime Plexiglas Base, 90 Base Hot 565-AA, SBS-TA LWC-54 Grade 40 Deck Concrete with Curing o.c.at two, ISO or or SECUROCK 565-SA-H -60.0 steel;6 ft Preparation Celcore HS Compound equally spaced, FlintBoard Gypsum-Fiber Roof Glasbase Base Sheet asphalt SBS-TA or or APP- span Rheology Sheet,Yosemite Fasteners staggered center ISO-T Board. Top surface APP-TA TA Modifying Venting Base or rows may be optionally Admixture Flintlastic Base 20 primed with FlintPrime. CONVENTIONAL SYSTEMS: NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 MEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 49 of 74 CONCRETETABLE 4D: LIGHTWEIGHT •VER STEEL DECKS-NEW • •N or R•• • OONEMO etc. SYSTEM TYPE A-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER LWIC(Note 14) Anchor Sheet Insulation Roof Cover(Note 15) System Deck MDP Treatment No. (Note 1) Deck Type Surface Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply (psf) Min.0.125-inch STURDY-DEK Min.470 psi, Asphaltic Cover All Board,min.0.25-inch min.2-inch 7-inch o.c.at the Weather/Empire DensDeck Prime or Min.22 ga., Celcore MF min.4-inch side Min.1.5" Base Sheet, Trufast FM- SECU ROCK Gypsum- (Optional) SBS-AA, type BV, Celcore S-1 Cellular Celcore PVA laps and 7-inch FlintBoard Plexiglas Base, 90 Base Fiber Roof Board, Hot BP-AA or SBS-AA, SBS-TA LWC-55 Grade 40 Deck Concrete with Curing o.c.at two, ISO or -60.0 steel;6 ft Preparation Celcore HS Compound equally spaced, FlintBoard Glasbase Base Sheet min.0.5-inch asphalt SBS-AA SBS-TA or or APP- Sheet,Yosemite Fasteners Structodek High APP-TA TA span Rheology Venting Base or staggered center ISO-T Density Fiberboard AdmixtureModifying Flintlastic Base 20 rows Roof Insulation or min.0.75-inch Fesco Board (homogeneous) Min.0.125-inch Min.470 psi, All STURDY-DEK min.2-inch Weather/Empire 7-inch o.c.at the Asphaltic Cover Min.22 ga., Celcore MF Base Sheet, Trufast FM- min.4-inch side Min.1.5" Board or min.0.25- type BV, Celcore S-1 Cellular Celcore PVA Plexiglas Base, 90 Base laps and 7-inch FlintBoard inch DensDeck Prime Hot SBS-TA or (Optional) SBS-TA LWC-56 Grade 40 Deck Concrete with Curing o.c.at two, ISO or or SECUROCK SBS-TA or or APP- -60.0 steel;6 ft Preparation Celcore HS Compound Glasbase Base Sheet equally spaced, FlintBoard Gypsum-Fiber Roof asphalt APP-TA App-TA TA span Rheology Sheet,Yosemite Fasteners staggered center ISO-T Board. Top surface Modifying Venting Base or Flintlastic Base 20 rows may be optionally Admixture primed with FlintPrime. ELASTIZELL(FL4994): SELF-ADHERING SYSTEMS: dMlii All 7-inch o.c.at the (Optional)Min.0.25- Min.22 ga., Min.490 psi, Weather/Empire min.4-inch side Min.1.5" inch DensDeck Prime type BV, min.2-inch laps and 7-inch FlintBoard Base Sheet, Trufast FM- or SECUROCK 90 Base, (Optional) LWC-57 Grade 40 None Elastizell with None Plexiglas Base o.c.at two, ISO or Gypsum-Fiber Roof Hot SBA-SA SBS-SA -67.5 steel;6 ft Zell-Crete Glasbase Base Sheet equally spaced, FlintBoard Board. Top surface asphalt SBS-SA span Fibers Sheet,Yosemite Fasteners staggered center ISO-T shall be primed with Venting Base or FlintPrime or Flintlastic Base 20 rows FlintPrime SA. HYBRID SYSTEMS: NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 50 of 74 CONCRETETABLE 4D: LIGHTWEIGHT •VER STEEL DECKS-NEW • •N or R•• • OONEMO etc. SYSTEM TYPE A-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER LWIC(Note 14) Anchor Sheet Insulation Roof Cover(Note 15) System Deck MDP Treatment No. (Note 1) Deck Type Surface Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply (psf) (Optional)Min. All 0.125-inch STURDY- Weather/Empire 7-inch o.c.at the DEK Asphaltic Cover Min.22 ga., Min.490 psi, Base Sheet, Trufast FM- min.4-inch side Min.1.5" Board or min.0.25- (Optional) SBS-AA, type BV, min.2-inch laps and 7-inch FlintBoard inch DensDeck Prime Plexiglas Base, 90 Base Hot SBS-AA, SBS-TA LWC-58 Grade 40 None Elastizell with None Glasbase Base Sheet asphalt SBS-TA or or APP- o.c.attwo, ISO or orSECUROCK SBS-SA-H -67.5 Sheet,Yosemite Fasteners steel;6 ft Zell-Crete equally spaced, FlintBoard Gypsum-Fiber Roof span Fibers staggered center ISO-T Board. Top surface APP-TA TA Venting Base or Flintlastic Base 20 rows may be optionally primed with FlintPrime. CONVENTIONAL SYSTEMS: 7-inch o.c.at the 4-inch side lap Min.2 ga. Min 350 psi, and 7-inch o.c.at steel orr Trufast FM- Min.1.5- BP-AA3, (Optional) Mill 90 Base Ply 2-inch Yosemite Venting two,equally (Optional)Additional Hot LWC-59 structural None None inch 18-inch BP-AA,SBS- SBS-AA -37.5* concrete Elastizell Base Fasteners spaced, ACFoam II layers base insulation asphalt grid AA deck. cellular LWIC staggered rows in the center of the sheet Min.0.125-inch STURDY-DEK Asphaltic Cover All Board,min.0.25-inch 7-inch o.c.at the Weather/Empire DensDeck Prime or Min.22 ga., Min.490 psi, min.4-inch side Min.1.5" Base Sheet, Trufast FM- SECU ROCK Gypsum- (Optional) SBS-AA, type BV, min.2-inch laps and 7-inch FlintBoard Plexiglas Base, 90 Base Fiber Roof Board, Hot BP-AA or SBS-AA, SBS-TA LWC-60 Grade 40 None Elastizell with None o.c.at two, ISO or 67.5 Glasbase Base Sheet min.0.5-inch asphalt SBS-AA SBS-TA or or APP- steel;6 ft Zell-Crete equally spaced, FlintBoard span Fibers Sheet,Yosemite Fasteners staggered center ISO-T Density Fib High APP-TA TA Venting Base or Density Fiberboard Flintlastic Base 20 rows Roof Insulation or min.0.75-inch Fesco Board (homogeneous) Min.0.125-inch All STURDY-DEK Weather/Empire 7-inch o.c.at the Asphaltic Cover Min.22 ga., Min.490 psi, Base Sheet, Trufast FM- min.4-inch side Min.1.5" Board or min.0.25- type BV, min.2-inch Plexiglas Base, 90 Base laps and 7-inch FlintBoard inch DensDeck Prime Hot SBS-TA or (Optional) SBS-TA LWC-61 Grade 40 None Elastizell with None Glasbase Base Sheet o.c.at two, ISO or or SECUROCK halt APP-TA SBS-TA or or APP- -67.5 steel;6 ft Zell-Crete equally spaced, FlintBoard Gypsum-Fiber Roof asp App-TA TA span Fibers Sheet,Yosemite Fasteners Venting Base or staggered center ISO-T Board. Top surface Flintlastic Base 20 rows may be optionally primed with FlintPrime. NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for F11-2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 51 of 74 NNEMOjetc. CONCRETETABLE4E: LIGHTWEIGHT DECKS OVER STEEL OR STRUCTURAL CONCRETE . CONSTRUCTION . BONDEDSYSTEMTYPEE: MECHANICALLY ATTACHED BASE SHEET, ROOF COVER LWIC(Note 14) Base Sheet Roof Cover(Note 15) System Deck MDP Treatment No. (Note 1) Deck LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply (psf) PRE-EXISTENT CELLULAR LWIC: SELF-ADHERING SYSTEMS: Min.22 ga., Type BV,Grade Min.300 psi,min.2- Trufast Twin Loc- 7-inch o.c.at the min.2-inch lap and 7- 33 steel;5 ft inch pre-existent Nail Assembled inch o.c.in two(2),equally spaced, span or None cellular lightweight None Flintlastic SA NailBase Fastener min. staggered center rows;Prime stress SBS-SA SBS SA 60.0 LWC-62 p ( gg structural insulating concrete. 1.8") plates with FlintPrime or FlintPrime SA concrete Note: To qualify the LWIC under this assembly,a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 73 lbf when tested per ANSI/SPRI FX-1 or TAS 105 Min.22 ga., Type BV,Grade Min.300 psi,min.2- Trufast Twin Loc- 9-inch o.c.at the min.2-inch lap and 9- 33 steel;5 ft inch pre-existent Nail Assembled inch o.c.in two(2),equally spaced, span or None cellular lightweight None Flintlastic SA NailBase Fastener min. staggered center rows;Prime stress SBS-SA SBS-SA 60.0 LWC-63 p ( gg structural insulating concrete. 1.8") plates with FlintPrime or FlintPrime SA concrete Note: To qualify the LWIC under this assembly,a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 93 lbf when tested per ANSI/SPRI FX-1 or TAS 105 HYBRID SYSTEMS: Min.22 ga., Type BV,Grade Min.300 psi,min.2- Glasbase;Flexiglas Trufast Twin Loc- 9-inch o.c.at the 4-inch lap and 9-inch SBS-AA,SBS- 33 steel;5 ft inch pre-existent Base;Flintlastic Base Nail Assembled span or None cellular lightweight None 20;All Weather min. stag in two cent equally spaced, SBS-SA-H TA or APP- 60.0 LWC-64 P / Fastener( staggered center rows TA structural insulating concrete. Empire Base 1.811) concrete Note: To qualify the LWIC under this assembly,a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105 Min.22 ga., Type BV,Grade Min.350 psi,min.3- Flexiglas Base; Trufast FM-90 7-inch o.c.at the 4-inch lap and 10-inch SBS-AA,SBS- 33 steel;5 ft inch pre-existent LWC-65 span or None cellular lightweight None Flintlastic Base 20 or Base Sheet stag in two cent equally spaced, SBS-SA-H TA or APP- -67.5 Poly SMS Base Fasteners staggered center rows TA structural insulating concrete. concrete Note: To qualify the LWIC under this assembly,a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97lbf when tested per ANSI/SPRI FX-1 or TAS 105 Min.22 ga., Type BV,Grade Min.300 psi,min.2- Trufast Twin Loc- 9-inch o.c.at the 4-inch lap and 9-inch SBS-AA,SBS- None 33 steel;5 ft inch pre-existent Poly SMS Base;Ultra Nail Assembled LWC-66 span or cellular lightweight None Poly SMS Base Fastener(min. stag in two cent equally spaced, SBS-SA-H TA or APP- 75.0 structural insulating concrete. 1.8") staggered center rows TA concrete NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 52 of 74 NNEMOjetc. CONCRETETABLE4E: LIGHTWEIGHT DECKS OVER STEEL OR STRUCTURAL CONCRETE . CONSTRUCTION . BONDEDSYSTEIVITYPEE: MECHANICALLY ATTACHED BASE SHEET, ROOF COVER System Deck LWIC(Note 14) Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Deck LWC Surface Type Fasteners Attach Base Ply Cap Ply (psf) Treatment Treatment Note: To qualify the LWIC under this assembly,a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 1101bf when tested per AN51/SPRI FX-1 or TA5105 CONVENTIONAL SYSTEMS: Min.22 ga., Glasbase;Flexiglas (Optional) Type BV,Grade Min.300 psi,min.2- Trufast Twin Loc- Base;Flintlastic Base 9-inch stag at the 4-inch lap and 9-inch BP-AA, SBS-AA,SBS- 33 steel;5 ft Nail Assembled inch pre-existent None None 20;All Weather/ stag in two cent equally spaced, SBS-AA, TA or APP- -60.0 LWC-67 span or cellular lightweight Fastener(min. structural insulating concrete. Empire Base;Yosemite 1 8„) staggered center rows SBS-TA or TA Venting Base APP-TA concrete Note: To qualify the LWIC under this assembly,a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88lbf when tested per ANSI/SPRI FX-1 or TAS 105 Min.22 ga., Glasbase;Flexiglas Type BV,Grade Min.300 psi,min.2- Trufast Twin Loc- Base;Flintlastic Base 7-inch stag at the 4-inch lap and 7-inch SBS-AA,SBS- 33 steel;5 ft inch pre-existent Nail Assembled None None 20;All Weather/ BP-AA or stag in two cent equally spaced, TA or APP- -67.5 LWC-68 span or cellular lightweight Fastener(min. SBS-AA structural insulating concrete. Empire Base;Yosemite 1 8„) staggered center rows TA concrete Venting Base Note: To qualify the LWIC under this assembly,a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 77lbf when tested perAN51/SPRI FX-1 or TAS 105 Min.22 ga., Type BV,Grade Min.350 psi,min.3- Flexiglas Base; BP-AA, None Trufast FM-90 7-inch stag at the 4-inch lap and 10-inch SBS-AA,SBS- 33 steel;5 ft inch pre-existent Flintlastic Base 20;Poly SBS-AA, LWC-69 span or cellular lightweight None SMS Base;Yosemite Base Sheet stag in two cent equally spaced, SBS-TA or TA or APP 67.5 structural insulating concrete. Venting Base Fasteners staggered center rows APP-TA TA concrete Note: To qualify the LWIC under this assembly,a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 971bf when tested per ANSI/SPRI FX-1 or TAS 105 Min.22 ga., Type BV,Grade Min.300 psi,min.2- Trufast Twin Loc- BP-AA, 9-inch stag at the 4-inch lap and 9-inch SBS-AA,SBS- 33 steel;5 ft inch pre-existent Poly SMS Base;Ultra Nail Assembled SBS-AA, span or None cellular lightweight None Pol SMS Base Fastener min. stag in two cent equally spaced, SBS-TA or TA or APP 75.0 LWC-70 pY ( staggered center rows TA structural insulating concrete. 1.8tt) APP-TA concrete Note: To qualify the LWIC under this assembly,a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110lbf when tested per ANSI/SPRI FX-1 or TAS 105 CELCORE(FL2037): SELF-ADHERING SYSTEMS: Min.470 psi,min.2- Min.22 ga.,type Celcore S-1 inch Celcore MF Celcore Trufast FM-90 7-inch o.c.at the min.4-inch side laps LWC-71 BV,Grade 40 Deck Cellular Concrete with PVA Curing Flintlastic SA NailBase Base Sheet and 7-inch o.c.at two,equally spaced, SBS-SA SBS-SA -45.0 steel;6 ft span Preparation Celcore HS Rheology Compound Fasteners staggered center rows Modifying Admixture NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 53 of 74 NNEMOletc. CONCRETETABLE4E: LIGHTWEIGHT DECKS OVER STEEL OR STRUCTURAL CONCRETE . CONSTRUCTION . BONDEDSYSTEMTYPEE: MECHANICALLY ATTACHED BASE SHEET, ROOF COVER LWIC(Note 14) Base Sheet Roof Cover(Note 15) System Deck MDP No. (Note 1) Deck LWC Surface Type Fasteners Attach Base Ply Cap Ply (psf) Treatment Treatment HYBRID SYSTEMS: Min.470 psi,min.2- All Weather/Empire Min.22 ga.,type Celcore S-1 inch Celcore MF Celcore Base Sheet,Flexiglas Trufast FM-90 7-inch o.c.at the min.4-inch side laps SBS-AA,SBS- LWC-72 BV,Grade 40 Deck Cellular Concrete with PVA Curing Base,Glasbase Base Base Sheet and 7-inch o.c.at two,equally spaced, SBS-SA-H TA or APP- -45.0 steel;6 ft span Preparation Celcore HS Rheology Compound Sheet or Flintlastic Base Fasteners staggered center rows TA Modifying Admixture 20 Min.470 psi,min.2- Min.22 ga.,type Celcore S-1 inch Celcore MF Celcore Yosemite Venting Base Trufast FM-90 7-inch o.c.at the min.4-inch side laps SBS-AA,SBS- LWC-73 BV,Grade 40 Deck Cellular Concrete with PVA Curing primed with FlintPrime Base Sheet and 7-inch o.c.at two,equally spaced, SBS-SA-H TA or APP- -45.0 steel;6 ft span Preparation Celcore HS Rheology Compound or FlintPrime SA Fasteners staggered center rows TA Modifying Admixture CONVENTIONAL SYSTEMS: Min.470 psi,min.2- All Weather/Empire (Optional) Min.22 ga.,type Celcore S-1 inch Celcore MF Celcore Base Sheet,Flexiglas Trufast FM-90 7-inch o.c.at the min.4-inch side laps BP-AA, SBS-AA,SBS- LWC-74 BV,Grade 40 Deck Cellular Concrete with PVA Curing Base,Glasbase Base Base Sheet and 7-inch o.c.at two,equally spaced, SBS-AA, TA or APP- -45.0 steel;6 ft span Preparation Celcore HS Rheology Compound Sheet,Yosemite Fasteners staggered center rows SBS-TA or TA Modifying Admixture Venting Base or APP TA Flintlastic Base 20 Min.22 ga., Min.300 psi,min 2- (Optional) type B steel at inch Celcore MF Celcore All Weather/Empire Trufast FM-90 9-inch o.c.at 4-inch laps and 12-inch BP-AA SBS-AA or LWC-75 max.5 ft spans None Cellular Concrete with PVA Curing Base;Flintlastic Base Base Sheet o.c.in two(2),equally spaced, -60.0 structural Celcore HS Rheology Compound 20;Poly SMS Base Fasteners staggered center rows SBS-AA or SBS-TA SBS TA concrete Modifying Admixture. Min.22 ga., Glasbase;Flexiglas Type BV,Grade Base;Flintlastic Base Min.300 psi,min 2- Celcore Trufast FM-90 7-inch o.c.at the 3-inch lap and 7-inch SBS-AA,SBS- 33 steel;5 ft 20;All Weather/ BP-AA or LWC-76 None inch Celcore Cellular PVA Curing Base Sheet o.c.in two(2),equally spaced, TA or APP- -75.0 span or Concrete. Compound Empire Base;Poly SMS Fasteners staggered center rows SBS-AA TA structural Base;Yosemite Venting concrete Base CONCRECEL(FL5584&FL10500): CONVENTIONAL SYSTEMS: Min.22 ga., Glasbase;Flexiglas Type BV,Grade Base;Flintlastic Base Concrecel Min.300 psi,min 2/o Concrecel 7-inch o.c.at the 3-inch lap and 7-inch (Optional) SBS-AA,SBS- Bonding inch Concrecel Curing 33 steel;5 ft 20;All Weather/ OMG CR Base Ply LWC-77 o.c.in two(2),equally spaced, BP-AA or TA or APP- -52.5 span or Empire Base;Poly SMS Fasteners(1.7) structural Agent Concrete. Compound Base;Yosemite Venting staggered center rows SBS-AA TA concrete Base ELASTIZELL(FL4994): NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 MEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 54 of 74 NNEMOjetc. CONCRETETABLE4E: LIGHTWEIGHT DECKS OVER STEEL OR STRUCTURAL CONCRETE . CONSTRUCTION . BONDEDSYSTEIVITYPEE: MECHANICALLY ATTACHED BASE SHEET, ROOF COVER LWIC(Note 14) Base Sheet Roof Cover(Note 15) System Deck MDP Treatment No. (Note 1) Deck LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: Min.22 ga.,type Min.490 psi,min.2- Trufast FM-90 7-inch o.c.at the min.4-inch side laps LWC-78 BV,Grade 40 None inch Elastizell with None Flintlastic SA NailBase Base Sheet and 7-inch o.c.at two,equally spaced, SBS-SA SBS-SA -45.0 steel;6 ft span Zell-Crete Fibers Fasteners staggered center rows HYBRID SYSTEMS' Min.26 ga.steel Glasbase;Flexiglas Trufast FM-90 Base at max 5 ft spans Min.200 psi,min 2- Base;Flintlastic Base Sheet Fasteners or 7Y2 Inch o.c.at the 4-inch lap and 7Y2 or structural inch Elastizell. SBS-AA,SBS- LWC-79 None None 20;All Weather/ Trufast Twin Loc-Nail inch o.c.in two(2),equally spaced, SBS-SA-H TA or APP- -30.0 Empire Base or Poly Assembled Fasteners staggered center rows TA concrete SMS Base (1.8 inch) Min.22 ga., Glasbase;Flexiglas Type BV,Grade g Trufast FM-90 Base ,33 steel;5 ft Min.200 psi min 2- Base;Flintlastic Base Sheet Fasteners or 7-inch o.c.at the 4-inch lap and 7-inch SBS-AA,SBS- LWC-80 None None 20;All Weather/ Trufast Twin Loc-Nail o.c.in two(2),equally spaced, SBS-SA-H TA or APP- -45.0 span or inch Elastizell. Empire Base or Poly Assembled Fasteners staggered center rows TA structural SMS Base (1.8 inch) concrete All Weather/Empire Min.22 ga.,type Min.490 psi,min.2- Base Sheet,Flexiglas Trufast FM-90 7-inch o.c.at the min.4-inch side laps SBS-AA,SBS- LWC-81 BV,Grade 40 None inch Elastizell with None Base,Glasbase Base Base Sheet and 7-inch o.c.at two,equally spaced, SBS-SA-H TA or APP- -45.0 steel;6 ft span Zell-Crete Fibers Sheet or Flintlastic Base Fasteners staggered center rows TA 20 Min.22 ga.,type Min.490 psi,min.2- Yosemite Venting Base Trufast FM-90 7-inch o.c.at the min.4-inch side laps SBS-AA,SBS- LWC-82 BV,Grade 40 None inch Elastizell with None primed with FlintPrime Base Sheet and 7-inch o.c.at two,equally spaced, SBS-SA-H TA or APP- -45.0 steel;6 ft span Zell-Crete Fibers or FlintPrime SA Fasteners staggered center rows TA CONVENTIONAL SYSTEMS: Glasbase;Flexiglas (Optional) Min.26 ga.steel Base;Flintlastic Base Trufast FM-90 Base at max 5 ft spans Min.200 psi,min 2- 20;All Weather/ Sheet Fasteners or 7%Inch o.c.at the 4-inch lap and 7/ BP-AA, SBS-AA,SBS- LWC-83 None None Trufast Twin Loc-Nail inch o.c.in two(2),equally spaced, SBS-AA, TA or APP- -30.0 or structural inch Elastizell. Empire Base;Poly SMS Assembled Fasteners staggered center rows SBS-TA or TA concrete Base;Yosemite Venting (1.8 inch) APP-TA Base Min.26 ga.steel Trufast FM-90 7%-inch o.c.at the 4-inch lap and 7%- LWC-84 at max 5 ft spans None Min.200 psi,min 2- None Flintlastic APP Base T Base Sheet inch o.c.in two(2),equally spaced, (Optional) APP-TA -30.0 or structural inch Elastizell. APP-TA concrete Fasteners staggered center rows NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 55 of 74 NNEMOjetc. CONCRETETABLE4E: LIGHTWEIGHT DECKS OVER STEEL OR STRUCTURAL CONCRETE . CONSTRUCTION . BONDEDSYSTEIVITYPEE: MECHANICALLY ATTACHED BASE SHEET, ROOF COVER LWIC(Note 14) Base Sheet Roof Cover(Note 15) System Deck MDP Treatment No. (Note 1) Deck LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply (psf) All Weather/Empire Base Sheet,Plexiglas (Optional) Min.22 ga.,type Min.490 psi,min.2- ,Base Glasbase Base Trufast FM-90 7-inch o.c.at the min.4-inch side laps BP-AA, SBS-AA,SBS- LWC-85 BV,Grade 40 None inch Elastizell with None Base Sheet and 7-inch o.c.at two,equally spaced, SBS-AA, TA or APP- -45.0 steel;6 ft span Zell-Crete Fibers Sheet,Yosemite Fasteners staggered center rows SBS-TA or TA Venting Base or APP-TA Flintlastic Base 20 Min.22 ga., Glasbase;Flexiglas Type BV,Gradee Base;Flintlastic Base Trufast FM-90 Base (Optional) 33 steel;5 ft Min.200 psi,min 2- All Weather/ Sheet Fasteners or 7-inch o.c.at the 4-inch lap and 7-inch BP-AA, SBS-AA,SBS- LWC-86 None None Trufast Twin Loc-Nail o.c.in two(2),equally spaced, SBS-AA, TA or APP- -45.0 span a inch Elastizell. Empire Base;Poly SMS structural Base;Yosemite Poly SMS Assembled Fasteners staggered center rows SBS-TA or TA Venting (1.8 inch) APP-TA concrete Base Min.22 ga., Type BV,Grade Trufast FM-90 7-inch o.c.at the 4-inch lap and 7-inch LWC-87 33 steel;5 ft None Min.200 psi,min 2- None Flintlastic APP Base T Base Sheet o.c.in two(2),equally spaced, (Optional) APP-TA -45.0 span or inch Elastizell. APP-TA structural Fasteners staggered center rows concrete COLD APPLIED SYSTEMS: Min.22 ga., Type BV,Grade Min.350 psi,min 2- Flintlastic Base 20; Trufast FM-90 7-inch o.c.at the 4-inch lap and 7-inch (Optional) LWC-88 33 steel;5 ft None inch Range II Elastizell None Flintlastic Poly SMS Base Sheet o.c.in two(2),equally spaced, BP-CA2 or SBS-CA2 -45.0 span or with Zell-Crete Fibers. Base Fasteners staggered center rows SBS-CA2 structural concrete Min.22 ga., Min.350 psi,min 2- Trufast FM-90 7-inch o.c.at the 4-inch lap and 7-inch (Optional) LWC-89 Type BV,Grade None inch Range II Elastizell None Glasbase;Flexiglas Base Sheet o.c.in two(2),equally spaced, BP-CA3 or SBS-CA3 -52.5 33 steel;5 ft with Zell-Crete Fibers. Base;Poly SMS Base Fasteners staggered center rows SBS-CA3 span Min.350 psi,min 2- Trufast FM-90 7-inch o.c.at the 4-inch lap and 7-inch (Optional) LWC-90 Structural None inch Range II Elastizell None Glasbase;Flexiglas Base Sheet o.c.in two(2),equally spaced, BP-CA3 or SBS-CA3 -60.0 concrete with Zell-Crete Fibers. Base;Poly SMS Base Fasteners staggered center rows SBS-CA3 MEARLCRETE(FL13492): CONVENTIONAL SYSTEMS: NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEIVIO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 56 of 74 NNEMOletc. CONCRETETABLE4E: LIGHTWEIGHT DECKS OVER STEEL OR STRUCTURAL CONCRETE . CONSTRUCTION . BONDEDSYSTEIVITYPEE: MECHANICALLY ATTACHED BASE SHEET, ROOF COVER LWIC(Note 14) Base Sheet Roof Cover(Note 15) System Deck MDP Treatment No. (Note 1) Deck LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply (psf) Min.22 ga., Glasbase;Flexiglas Type BV,Grade Base;Flintlastic Base 7-inch o.c.at the 4-inch lap and 7-inch (Optional) SBS-AA,SBS- 33 steel;5 ft Min.250 psi,min 2- 20;All Weather/ OMG CR Base Ply LWC 91 span or None inch Mearlcrete. None Empire Base;Poly SMS Fasteners(1.7) stag in two cent equally spaced, A or TA or APP- 45.0 SBS-AA TA structural Base;Yosemite Venting staggered center rows BS- concrete Base Min.22 ga., Type BV,Grade 7-inch o.c.at the 4-inch lap and 7-inch (Optional) SBS-AA,SBS- LWC-92 33 steel;5 ft None Min.250 psi,min 2- None Poly SMS Base OMG CR Base Ply o.c.in two(2),equally spaced, BP-AA or TA or APP- -52.5 span or inch Mearlcrete. Fasteners(1.7) staggered center rows SBS AA TA structural concrete Min.22 ga., Glasbase;Flexiglas Type BV,Grade Base;Flintlastic Base 7-inch o.c.at the 4-inch lap and 7-inch (Optional) SBS-AA,SBS- 33 steel;5 ft Min.300 psi,min 2- 20;All Weather/ OMG CR Base Ply LWC 93 span or None inch Mearlcrete. None Empire Base;Poly SMS Fasteners(1.7) stag in two cent equally spaced, A or TA or APP- 52.5 SBS-AA TA structural Base;Yosemite Venting staggered center rows BS- concrete Base CONCRETETABLE 4F: LIGHTWEIGHT . ••• • OR RECOVER STEM TYPE E: MECHANICALLY ATTACHED BASE SHEET,Y lima" BONDED ROOF COVER System Deck(Note 1) LWIC(Note 14) Base Sheet Roof Cover(Note 15) MDP No. Type Surfacing Base Fasteners Spacing Base Ply Cap Ply (psf) PRE-EXISTENT CELLULAR LWC: Min.470 psi,Min.2-inch LWC pallpall (tear-off),repairs with Celcore SBS Flintlastic Trufast Versa Fasteners 9-inch o.c.within the Min.22 ga., thick,existing(>28 days For rs Ultra Poly (min.2.25")&Plates;two min.5-inch wide, (Optional)SBS-TA or Type BV, SBS-TA or APP-TA -75.0 old)cellular lightweight SMS Base (2)screws per plate at heat-welded side APP-TA LWC-94 Grade 40 steel concrete (Sanded Bonding Surface) Sheet 180°from each other* laps Note: *Field withdrawal resistance testing(Note 11)shall yield minimum 322 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance. For recover installations,screws shall be of sufficient length for minimum 2.25"embedment into the existing LWC assembly. NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEVIO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 57 of 74 NNEMOjetc. E :. 1 1 .00 0 i System Deck(Note 1) LWIC(Note 14) Roof Cover(Note 15) MDP No. Type Surfacing Base Ply Cap Ply (psf) PRE-EXISTENT CELLULAR LWC: Flintlastic Ultra Poly SMS Base Sheet applied in Min.400 psi,Min.2-inch Repair LWC spalls Millennium Hurricane Force Membrane Min.22 ga., Adhesive HS,ribbons max.6-inch o.c. 3-inch LWC-95 Type BV, thick,existing(>28 days with Celcore n wide side laps and 6-inch wide end laps are SBS-CA1 -75.0 Grade 40 steel old)cellular lightweight (Sanded Bonding hot-air-welded,torch-welded or sealed with concrete Surface) Millennium Hurricane Force Lap and Flashing Adhesive Flintlastic Ultra Poly SMS Base Sheet applied in Flintlastic FIR Cap 30,Flintlastic FR Cap 30 CoolStar,Flintlastic FR-P,Flintlastic Min.400 psi,Min.2-inch Repair LWC spalls Millennium Hurricane Force Membrane FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar, Min.22 ga., ribbons max.6-inch o.c. 3-inch Adhesive HS, thick,existing(>28 days with Celcore SBS Flintlastic GMS or Flintlastic GMS CoolStar,applied in Millennium Hurricane LWC-96 Type BV, wide side laps and 6-inch wide end laps are -97.5 Grade 40 steel old)cellular lightweight (Sanded Bonding hot-air-welded,torch-welded or sealed with Force Membrane Adhesive HS,continuous ribbons maximum 6-inch o.c. 3- concrete Surface) Millennium Hurricane Force Lap and Flashing inch wide side laps and 6-inch wide end laps are hot-air-welded,torch- Adhesive welded or sealed with Millennium Hurricane Force Lap and Flashing Adhesive NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 58 of 74 NNEMOjetc. ... FIBER . .. REROOF(TEAR-OFF) BONDEDSYSTEM TYPE A-1:BONDED INSULATION, ROOF Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Deck MDP No. (Notes 1&12) Type Attach Type Attach gase PlyT Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) SELF-ADHERING SYSTEMS: Existing Min.1.5-inch FlintBoard ISO,ACFoam II,ENRGY 3 Min.0.25-inch DensDeck primed with CWF-1. Tectum(re- or Multi-Max FA3 OB500 FlintPrime or FlintPrime SA;or OB500 SBS-SA (Optional)SBS-SA SBS-SA -45.0* roof only) SECUROCK Gypsum-Fiber Roof Board Min.1.0-inch ISO 95+GL,H-Shield,H-Shield CG, ICP BOARD- Min.0.25-inch DensDeck primed with ICP BOARD- CWF-2. Tectum ENRGY 3 or min.1.3-inch ACFoam III,Min.1.5- MAX or CR- FlintPrime or FlintPrime SA;or MAX or CR- SBS-SA (Optional)SBS-SA SBS-SA -52.5 inch Multi-Max FA3 or Ultra-Max 20 SECUROCK Gypsum-Fiber Roof Board 20 CONVENTIONAL SYSTEMS: Existing (Optional)BP-AA, Min.1.5-inch FlintBoard ISO,ACFoam II,ENRGY 3 Min.0.5-inch Structodek High Density BP-AA or SBS-AA,SBS- CWF-3. Tectum(re- or Multi-Max FA3 OB500 Fiberboard OB500 SBS-AA SBS-AA,SBS-TA or TA or APP-TA -45.0* roof only) APP-TA Existing Min.1.5-inch FlintBoard ISO,ACFoam II,ENRGY 3 Min.0.25-inch SECUROCK Gypsum- BP-AA,SBS- (Optional)BP-AA, SBS-AA,SBS- CWF-4. Tectum(re- OB500 Fiber Roof Board or DensDeck or OB500 AA,SBS-TA SBS-AA,SBS-TA or -45.0* roof only) or Multi-Max FA3 DensDeck Prime or APP-TA APP-TA TA or APP-TA Min.1.0-inch ISO 95+GL,H-Shield,H-Shield CG, ICP BOARD- Min.0.5-inch Structodek High DensityICP BOARD- (Optional)BP-AA, CWF-5. Tectum Fiberboard or DuraBoard BP-AA or SBS-AA,SBS- ENRGY 3 or min.1.3-inch ACFoam III,Min.1.5- MAX or CR- (homogeneous)or min.1.5-inch MAX or CR- SBS-AA SBS-AA,SBS-TA or TA or APP-TA FescoBoard(laminated) -52.5 inch Multi-Max FA3 or Ultra 20 20 APP TA Min.1.0-inch ISO 95+GL,H-Shield,H-Shield CG, ICP BOARD- Min.0.25-inch SECUROCK Gypsum- ICP BOARD- BP-AA,SBS- (Optional)BP-AA, SBS-AA,SBS- CWF-6. Tectum ENRGY 3 or min.1.3-inch ACFoam III,Min.1.5- MAX or CR- Fiber Roof Board or DensDeck or MAX or CR- AA,SBS-TA SBS-AA,SBS-TA or -52.5 inch Multi-Max FA3 or Ultra-Max 20 DensDeck Prime 20 or APP-TA APP-TA TA or APP-TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 MEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 59 of 74 NNEMOletc. WOOF FIBER DECKS BONDEDSYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION, ROOF Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) System Deck Attach Attach MDP No. (Note 1) Type Fasteners Attach Type a sf Yp (Note 11) YP (Notes Type (Notes Base Ply Ply Cap Ply (P ) 6,7,8) 6,7,8) HYBRID SYSTEMS: Glasbase;Flexiglas Trufast Twin 6-inch o.c.at the 4- Min.1.5-inch (Optional)Min.0.25- (Optional) Base;Flintlastic Base Loc-Nail inch lap and 10-inch ACFoam II, SBS-AA, inch SECUROCK SBS-AA, CWF-7. TectumBS-TA 20;AlAll Weather/ Assembled o.c.in two(2),equally FlintBoard ISO, HA HA SBS-SA-H SBS-TA or -60.0 Empire Base or Fastener(Field spaced,staggered ENRGY 3 or Multi- Gypsum-Fiber Roof or APP-TA Yosemite Venting Base W/D>80 Ibf) center rows Max FA3 Board APP-TA Glasbase;Flexiglas Trufast Twin 7-inch o.c.at the 4- Min.1.5-inch (Optional)Min.0.25- (Optional) Base;Flintlastic Base Loc-Nail inch lap and 7-inch ACFoam II, SBS-AA, inch SECUROCK SBS-AA, CWF-8. Tectum 20;All Weather/ Assembled o.c.in two(2),equally FlintBoard ISO, HA HA SBS-SA-H SBS-TA or -60.0 Empire Base;Yosemite Fastener(Field spaced,staggered ENRGY 3 or Multi- Gypsum-Fiber Roof SBS-TA or APP-TA Venting Base W/D>69 Ibf) center rows Max FA3 Board APP-TA CONVENTIONAL SYSTEMS: Glasbase;Flexiglas Trufast Twin 6-inch o.c.at the 4- Min.1.5-inch Min.0.75-inch Base;Flintlastic Base Loc-Nail inch lap and 10-inch ACFoam II, FescoBoard BP AA or (Optional) SBS-AA, CWF-9. Existing 20;All Weather/ Assembled o.c.in two(2),equally FlintBoard ISO, HA (homogeneous)or min. HA BP-AA or SBS-TA or -60.0 Tectum Empire Base or Fastener(Field spaced,staggered ENRGY 3 or Multi- 0.5-inch Structodek SBS-AA SBS-AA APP-TA Yosemite Venting Base W/D>80 Ibf) center rows Max FA3 High Density Fiberboard Glasbase;Flexiglas Trufast Twin 7-inch o.c.at the 4- Min.1.5-inch Min.0.75-inch Base;Flintlastic Base Loc-Nail inch lap and 7-inch ACFoam II, FescoBoard (Optional) SBS-AA, CWF-10. Existing 20;All Weather Assembled o.c.in two(2),equally FlintBoard ISO, HA BP-AA or Tectum / ( ) q y (homogeneous)or min. HA SBS-AA BP-AA or SBS-TA or -60.0 Empire Base;Yosemite Fastener(Field spaced,staggered ENRGY 3 or Multi- 0.5-inch Structodek SBS-AA APP-TA Venting Base W/D>69 Ibf) center rows Max FA3 High Density Fiberboard NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 60 of 74 NNEM01letc. ..D FIBER . BONDEDSYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, .. System Deck Base Insulation Layer(s) Top Insulation Layer Roof Cover(Note 15) MDP No. (Note 1) Type Fasteners(Note 11) Attach Base Ply Ply Cap Ply (psf) Min.0.5-inch Structodek High OMG Polymer GypTec Existing (Optional)One or more layers, 1 per 2.0 (Optional)BP-AA,SBS-AA, SBS-AA,SBS- CWF-11. Tectum any combination,loose laid Density Fiberboard Roof with 3"GypTec Plate ftz BP-AA or SBS-AA SBS-TA or APP-TA TA or APP-TA -45.0* Insulation (Field W/D>180 Ibf) Existing (Optional)One or more layers, Min.0.25-inch DensDeck or OMG Polymer GypTec 1 per 1.8 BP-AA,SBS-AA,SBS- (Optional)BP-AA,SBS-AA, SBS-AA,SBS- CWF-12. Tectum any combination,loose laid DensDeck Prime with 3"GypTec Plate ft2 TA or APP-TA SBS-TA or APP-TA TA or APP-TA -45.0* (Field W/D>160 Ibf) Min.0.5-inch Structodek High Trufast Twin Loc-Nail CWF-13. Existing (Optional)One or more layers, Density Fiberboard Roof Assembled Fasteners 1 per Z2.0 BP-AA or SBS-AA (Optional)BP-AA,SBS-AA, SBS SBS-TA or APP-TA TA or r A,SBS-APP-TA -45.0* Tectum any combination,loose laid ft Insulation (Field W/D>180 Ibf) Min.0.25-inch DensDeck or Trufast Twin Loc-Nail Existing (Optional)One or more layers, DensDeck Prime or 1 per 2.0 BP-AA,SBS-AA,SBS- (Optional)BP-AA,SBS-AA, SBS-AA,SBS- CWF-14. Tectum any combination,loose laid SECUROCK Gypsum-Fiber Assembled Fasteners ftZ TA or APP-TA SBS-TA or APP-TA TA or APP-TA 45.0* Roof Board (Field W/D>180 Ibf) TABLE 5D: CEMENTITOUS WOOD FIBER DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)OR REROOF SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Base Fasteners(Note 11) Attach Base Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: Trufast Twin Loc-Nail Assembled 6-inch o.c.at the 4-inch lap and 10-inch o.c.in two CWF-15. Tectum Flintlastic SA NailBase Fastener(Field W/D>80 Ibf) (2),equally spaced,staggered center rows SBS SA SBS SA 60.0 CWF-16. Tectum Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled 7-inch o.c.at the 4-inch lap and 7-inch o.c.in two SBS-SA SBS-SA -60.0 Fastener(Field W/D>69 Ibf) (2),equally spaced,staggered center rows CONVENTIONAL SYSTEMS: Existing Trufast Insuldeck Loc-Nail Base CWF-17. Tectum All Weather/Empire Base;Yosemite Venting Sheet Fastener(Field W/D>53 (-inch all at the 4-inch lap and enter rows s in two BP-AA or SBS-AA SBS-AA -30.0* Base (2),equally spaced,staggered center rows (re roof only) Ibf) Existing Trufast Insuldeck Loc-Nail Base _ All Weather/Empire Base;Yosemite Venting 7/:_inch o.c.at the 4-inch lap and 7/inch o.c.in CWF-18. Tectum Base Sheet Fastener(Field W/D>55 two(2),equally spaced,staggered center rows BP-AA or SBS-AA SBS-AA -45.0* (re roof only) Ibf) Glasbase;Flexiglas Base;Flintlastic Base 20; Trufast Twin Loc-Nail Assembled 6-inch o.c.at the 4-inch lap and 10-inch o.c.in two SBS-AA,SBS-TA CWF-19. Tectum All Weather/Empire Base or Yosemite BP-AA or SBS-AA -60.0 Venting Base Fastener(Field W/D>80 Ibf) (2),equally spaced,staggered center rows or APP-TA Glasbase;Flexiglas Base;Flintlastic Base 20 Trufast Twin Loc-Nail Assembled 7-inch o.c.at the 4-inch lap and 7-inch o.c.in two SBS-AA,SBS-TA CWF-20. Tectum or All Weather/Empire Base;Yosemite Fastener(Field W/D>77 Ibf) (2),equally spaced,staggered center rows BP-AA or SBS-AA or APP-TA -67.5 Venting Base NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 61 of 74 NNEMOjetc. TABLE 6A: GYPSUM DECKS- •.. MONOMER___:E;I6 SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Deck MDP No. (Notes 1&12) Type Attach Type Attach Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) SELF-ADHERING SYSTEMS: Existing sound Min.1.5-inch FlintBoard ISO,FlintBoard H CK G-1. gypsum or ISO,ACFoam II,ACFoam III,ENRGY 3,H- M-OSFA Min. m-Fi er Roof Board M-OSFA SBS-SA Gypsum-Fiber Roof Board (Optional)SBS-SA SBS-SA -172.5 gypsum plank Shield or H-Shield CG Existing sound Min.1.5-inch ACFoam II,FlintBoard,ENRGY 3 Min.0.25-inch DensDeck G-2. gypsum or or Multi-Max FA M-OSFA primed with FlintPrime or M-OSFA SBS-SA (Optional)SBS-SA SBS-SA -192.5 gypsum plank FlintPrime SA Existing sound One or more layer(s),min.1.5-inch thick Min.0.25-inch SECUROCK G-3. gypsum or FlintBoard ISO,FlintBoard H ISO,ACFoam II, M-PG1 Gypsum-Fiber Roof Board M-PG1 SBS-SA (Optional)SBS-SA SBS-SA -172.5 gypsum plank ACFoam III,H-Shield or H-Shield CG Existing sound Min.1.5-inch ACFoam II,FlintBoard ISO or Min.0.25-inch DensDeck G-4. gypsum or ENRGY 3 OB500 primed with FlintPrime or OB500 SBS-SA (Optional)SBS-SA SBS-SA -135.0 gypsum plank FlintPrime SA Existing sound One or more layer(s),min.1.5-inch thick Min.0.25-inch SECUROCK G-5. gypsum or FlintBoard ISO,FlintBoard H ISO,ACFoam II, OB500 Gypsum-Fiber Roof Board OB500 SBS-SA (Optional)SBS-SA SBS-SA -172.5 gypsum plank ACFoam III,H-Shield or H-Shield CG Existing sound One or more layer(s),min.1.5-inch thick ICP BOARD- Min.0.25-inch SECUROCK ICP BOARD- G-6. gypsum or FlintBoard ISO,FlintBoard H ISO,ACFoam II, MAX Gypsum-Fiber Roof Board MAX SBS-SA (Optional)SBS-SA SBS-SA -172.5 gypsum plank ACFoam III,H-Shield or H-Shield CG One or more layer(s),min.1.0-inch ISO 95+ Existing sound GL,FlintBoard H ISO,H-Shield,H-Shield CG, Min.0.25-inch SECUROCK G-7. gypsum or ENRGY 3 or min.1.3-inch ACFoam III,Min. CR-20 Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional)SBS-SA SBS-SA -172.5 gypsum plank 1.5-inch FlintBoard ISO,ACFoam II,Multi- Max FA3 or Ultra-Max Existing sound Min.1.0-inch ISO 95+GL,H-Shield,H-Shield Min.0.25-inch DensDeck G 8 CG,ENRGY 3 or min.1.3-inch ACFoam III, gypsum or Min.1.5-inch FlintBoard I50,ACFoam II, CR-20 primed with FlintPrime or CR-20 SBS-SA (Optional)SBS-SA SBS-SA -192.5 gypsum plank FlintPrime SA Multi-Max FA3 or Ultra-Max HYBRID SYSTEMS: M-OSFA,M- M-OSFA,M- Existing sound One or more layer(s),min.1.5-inch thick PG1,ICP (Optional)Min.0.25-inch PG1,ICP (Optional)SBS-AA, SBS-AA,SBS- G-9. gypsum or FlintBoard ISO,FlintBoard H ISO,ACFoam II, BOARD-MAX, SECUROCK Gypsum-Fiber Roof BOARD-MAX, SBS-SA-H -187.5 gypsum plank ACFoam III,H-Shield or H-Shield CG ICP CR-20 or Board ICP CR-20 or SBS-TA or APP-TA TA or APP-TA OB500 OB500 CONVENTIONAL SYSTEMS: NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7TR EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 62 of 74 NNEMOjetc. BONDEDTABLE 6A: GYPSUM DECKS-REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION, ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Deck MDP (Notes 6,7,8) No. (Notes 1&12) Type Attach Type Attach Base Ply Ply Cap Ply (psf) (Notes 6,7,8) Existing sound ,(Optional)BP-AA Min.1.5-inch ACFoam II,FlintBoard ISO, Min.0.5-inch Structodek High BP-AA or SBS- SBS-AA,SBS- G-10. gypsum or ENRGY 3 or H-Shield M-OSFA Density Fiberboard M-OSFA AA SBS-AA,SBS-TA or TA or APP-TA -127.5 gypsum plank APP-TA Existing sound One or more layer(s),min.1.5-inch thick Min.0.25-inch SECUROCK BP-AA or SBS- (Optional)BP-AA, SBS-AA,SBS- G-11. gypsum or FlintBoard ISO,FlintBoard H ISO,ACFoam II, M-OSFA M-OSFA AA,SBS-TA or SBS-AA,SBS-TA or -187.5 gypsum plank ACFoam III,H-Shield or H-Shield CG Gypsum-Fiber Roof Board APP TA APP TA TA or APP-TA Existing sound (Optional)BP-AA, G-12. gypsum or Min. inch ACFoam II,FlintBoard ISO, M-OSFA Min.0.25-inch DensDeck M-OSFA or SBS- SBS-AA,SBS-TA or SBS- A,SBS- -232.5 gypsum plank ENRGYY 3 3 or H-Shield AA AA APP TA TA orr APP-TA Existing sound BP-AA or SBS- (Optional)BP-AA, G-13. gypsum or Min.2-inch ACFoam II,FlintBoard ISO, M-OSFA Min.um-Finch Roof Board M-OSFA AA,SBS-TA or SBS-AA,SBS-TA or SBS-AA,SBS- -202.5 ENRGY 3 or H-Shield Gypsum-Fiber Roof Board TA or APP-TA gypsum plank APP-TA APP-TA Existing sound One or more layer(s),min.1.5-inch thick BP-AA or SBS- (Optional)BP-AA, Min.0.25-inch SECUROCK SBS-AA,SBS- G-14. gypsum or FlintBoard ISO,FlintBoard H ISO,ACFoam ll, M-PG1 M-PG1 AA,SBS-TA or SBS-AA,SBS-TA or -187.5 gypsum plank ACFoam III,H-Shield or H-Shield CG Gypsum-Fiber Roof Board APP-TA APP-TA TA or APP-TA Existing sound (Optional)BP-AA, Min.1.5-inch ACFoam II,FlintBoard ISO, Min.0.5-inch Structodek High BP-AA or SBS- SBS-AA,SBS- G-15. gypsum or ENRGY 3 or H-Shield OB500 Density Fiberboard OB500 AA SBS-AA,SBS-TA or TA or APP-TA -120.0 gypsum plank APP-TA Existing sound Min. Min.0.25-inch DensDeck, BP-AA,SBS- (Optional)BP-AA, SBS-AA,G-16. gypsum or inch ACFoam II,FlintBoard ISO, OB500 DensDeck Prime or SECUROCK OB500 AA,SBS-TA or SBS-AA,SBS-TA or r SBS- -135.0 gypsum plank ENRGYY 3 3 or H-Shield Gypsum-Fiber Roof Board APP-TA APP-TA TA or APP-TA Existing sound One or more layer(s),min.1.5-inch thick BP-AA,SBS- (Optional)BP-AA, G-17. gypsum or FlintBoard ISO,FlintBoard H ISO,ACFoam II, OB500 Min.um-Finch Roof Board OB500 AA,SBS-TA or SBS-AA,SBS-TA or SBS-AA,SBS- -187.5 gypsum plank ACFoam III,H-Shield or H-Shield CG Gypsum-Fiber Roof Board APP-TA APP-TA TA or APP-TA Existing sound One or more layer(s),min.1.5-inch thick ,BP-AA,SBS- (Optional)BP-AA ICP BOARD- Min.0.25-inch SECUROCK ICP BOARD- SBS-AA,SBS- G-18. gypsum or FlintBoard ISO,FlintBoard H ISO,ACFoam ll, AA,SBS-TA or SBS-AA,SBS-TA or -187.5 gypsum plank ACFoam III,H-Shield or H-Shield CG MAX Gypsum Fiber Roof Board MAX APP-TA APP-TA TA or APP-TA Existing sound Min.1.0-inch ISO 95+GL,H-Shield,H-Shield G-19. gypsum or CG,ENRGY 3 or min.1.3-inch ACFoam III, CR-20 Min. inch DensDeck or CR-20 SBS-TA (Optional)SBS-TA SBS-TA -180.0 gypsum plank Min.1.5-inch Multi-Max FA3 or Ultra-Max DensDDeckeck Prime Min.0.5-inch Structodek High Existing sound Min.1.0-inch ISO 95+GL,H-Shield,H-Shield Density Fiberboard or (Optional)BP-AA, G-20. gypsum or CG,ENRGY 3 or min.1.3-inch ACFoam III, CR-20 DuraBoard(homogeneous)or CR-20 or SBS SBS-AA,SBS-TA or SBS-r A,SBS-APP-TA AA TA or -180.0 gypsum plank Min.1.5-inch Multi-Max FA3 or Ultra-Max min.1.5-inch FescoBoard AA APP-TA (laminated) Existing sound One or more layer(s),min.1.5-inch thick BP-AA,SBS- (Optional)BP-AA, Min.0.25-inch SECUROCK SBS-AA,SBS- G-21. gypsum or FlintBoard ISO,FlintBoard H ISO,ACFoam ll, CR-20 CR-20 AA,SBS-TA or SBS-AA,SBS-TA or -187.5 gypsum plank ACFoam III,H-Shield or H-Shield CG Gypsum Fiber Roof Board APP-TA APP-TA TA or APP-TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 MEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 63 of 74 NNEMOletc. BONDEDTABLE 6A: GYPSUM DECKS—REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION, ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Deck MDP (Notes 6,7,8) No. (Notes 1&12) Type Attach Type Attach Base Ply Ply Cap Ply (psf) (Notes 6,7,8) Existing sound Min.1.0-inch ISO 95+GL,H-Shield,H-Shield (Optional)BP-AA, Min.0.25-inch SECUROCK BP-AA or SBS- SBS-AA,SBS- G-22. gypsum or CG,ENRGY 3 or min.1.3-inch ACFoam III, CR-20 Gypsum-Fiber Roof Board CR-20 AA SBS-AA,SBS-TA or TA or APP-TA -225.0 gypsum plank Min.1.5-inch Multi-Max FA3 or Ultra-Max APP-TA Existing sound Min.1.0-inch ISO 95+GL,H-Shield,H-Shield Min.0.25-inch SECUROCK SBS-TA or (Optional)SBS-TA SBS-TA or G-23. gypsum or CG,ENRGY 3 or min.1.3-inch ACFoam III, CR-20 Gypsum-Fiber Roof Board CR-20 APP-TA or APP-TA APP-TA -232.5 gypsum plank Min.1.5-inch Multi-Max FA3 or Ultra-Max Existing sound Min.1.0-inch ISO 95+GL,H-Shield,H-Shield BP-AA or SBS- (Optional)BP-AA, SBS-AA,SBS- G-24. gypsum or CG,ENRGY 3 or min.1.3-inch ACFoam III, CR-20 Min.0.25-inch DensDeck CR-20 AA SBS-AA,SBS-TA or TA or APP-TA -240.0 gypsum plank Min.1.5-inch Multi-Max FA3 or Ultra-Max APP-TA TABLE 6B: GYPSUM DECKS— •• • SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) System Deck MDP No. (Note 1) Type Fasteners(Note 11) Attach Type Attach Type Attach Base Ply Ply Cap Ply (psf) HYBRID SYSTEMS: Glasbase;Flexiglas 6-inch o.c.at the 4- Min.1.5-inch Base;Flintlastic Trufast Twin Loc- inch lap and 10-inch (Optional) Existing sound ACFoam II, SBS-AA, Base 20;All Nail Assembled o.c.in two(2), SBS-SA- SBS-AA, G-25. gypsum or FlintBoard ISO, HA None N/A SBS-TA or -60.0 gypsum plank Weather/Empire Fastener(Field equally spaced, ENRGY 3 or Multi- H SBS-TA or APP-TA Base or Yosemite W/D>80 Ibf) staggered center Max FA3 APP-TA Venting Base rows Glasbase;Flexiglas 7-inch o.c.at the 4- Min.1.5-inch Base;Flintlastic Trufast Twin Loc- inch lap and 7-inch (Optional) Existing sound ACFoam II, SBS-AA, Base 20;All Nail Assembled o.c.in two(2), SBS-SA- SBS-AA, G-26. gypsum or FlintBoard ISO, HA None N/A SBS-TA or -60.0 Weather/Empire Fastener(Field equally spaced, H SBS-TA or gypsum plank Base;Yosemite W/D>69 Ibf) staggered center ENRGY 3 or Multi- APP-TA APP-TA Venting Base rows Max FA3 CONVENTIONAL SYSTEMS: Trufast FM-75 or 9-inch o.c.at the 4- All Weather inch lap and 18-inch FM-90 Base (Optional)Min.1.5- Min.0.75-inch / Existing sound Empire Base; o.c.in two(2), BP-AA or Sheet Fastener inch ACFoam ll, FescoBoard (Optional) SBS-AA, G-27. gypsum or or Twin Loc-Nail FlintBoard ISO, HA (homogeneous)or min. HA BP-AA or SBS-TA or -45.0* gypsum plank Yosemite Venting Assembled equally spaced, ENRGY 3 or Multi- 0.5-inch Structodek SBS-AA SBS-AA APP-TA Base Fastener(Field staggered center Max FA3 High Density Fiberboard W/D>100 Ibf) rows NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 MEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 64 of 74 NNEMOjetc. BONDEDTABLE 613: GYPSUM DECKS—REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION, ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) System Deck MDP No. (Note 1) Type Fasteners Attach T YP (Note 11) Type Attach Type Attach Base Ply Ply Cap Ply (psf) Glasbase;Flexiglas 6-inch o.c.at the 4- Base;Flintlastic Trufast Twin Loc- inch lap and 10-inch Min. inch Min.0.75-inch Existing sound ACFoam II, FescoBoard (Optional) SBS-AA, Base 20;All Nail Assembled o.c.in two(2), BP-AA or G-28. gypsum or FlintBoard ISO, HA (homogeneous)or min. HA BP-AA or SBS-TA or -60.0 gypsum plank Weather/Empire Fastener(Field equally spaced, ENRGY 3 or Multi- 0.5-inch Structodek SBS-AA SBS-AA APP-TA Base or Yosemite W/D>80 Ibf) staggered center Max FA3 High Density Fiberboard Venting Base rows Glasbase;Flexiglas 7-inch o.c.at the 4- Min.1.5-inch Min.0.75-inch Base;Flintlastic Trufast Twin Loc- inch lap and 7-inch Existing sound ACFoamll, FescoBoard (Optional) SBS-AA, Base 20;All Nail Assembled o.c.in two(2), BP-AA or G-29. gypsum or FlintBoard ISO, HA (homogeneous)or min. HA BP-AA or SBS-TA or -60.0 Weather/Empire Fastener (Field equally spaced, SBS-AA gypsum plank ENRGY 3 or Multi- 0.5-inch Structodek SBS-AA APP-TA Base;Yosemite W/D>69 Ibf) staggered center Max FA3 High Density Fiberboard Venting Base rows TABLE 6C: GYPSUM DECKS— ••• • SYSTEIVITYPEC: MECHANICALLY ATTACHED INSULATION,BONDED ROOFCOVER System Deck Base Insulation Layer(s) Top Insulation Layer Roof Cover(Note 15) MDP(psf) No. (Note 1) Type Fasteners(Note 11) Attach Base Ply Ply Cap Ply Existing sound (Optional)One or more Min.0.5-inch Structodek OMG Polymer GypTec with 3" BP-AA or SBS- (Optional)BP-AA, SBS-AA, G-30. gypsum or layers,any combination, High Density Fiberboard GypTec Plate(Field W/D>180 1 per 2.0 ftZ AA SBS-AA,SBS-TA or SBS-TA or -45.0* gypsum plank loose laid Roof Insulation Ibf) APP-TA APP-TA Existing sound (Optional)One or more Min.0.25-inch DensDeck or OMG Polymer GypTec with 3" BP-AA,SBS- (Optional)BP-AA, SBS-AA, G-31. gypsum or layers,any combination, GypTec Plate(Field W/D>160 1 per 1.8 ftZ AA,SBS-TA or SBS-AA,SBS-TA or SBS-TA or -45.0* gypsum plank loose laid DensDeck Prime Ibf) APP-TA APP-TA APP-TA Existing sound (Optional)One or more Min.0.5-inch Structodek Trufast Twin Loc-Nail Assembled AA BP-AA or SBS- (Optional)BP-AA, SBS-AA, G-32. gypsum or layers,any combination, High Density Fiberboard 1 per 2.0 ftZ SBS-AA,SBS-TA or SBS-TA or -45.0* gypsum plank loose laid Roof Insulation Fasteners(Field W/D>180 Ibf) APP-TA APP-TA 25-inch DensDeck or 0. Existing sound (Optional)One or more Min. BP-AA,SBS- (Optional)BP-AA, SBS-AA, DensDeck Prime or Trufast Twin Loc-Nail Assembled G-33. gypsum or layers,any combination, 1 per 2.0 ftz AA,SBS-TA or SBS-AA,SBS-TA or SBS-TA or -45.0* gypsum plank loose laid SECUROCK Gypsum-Fiber Fasteners(Field W/D>180 Ibf) APP-TA APP-TA APP-TA Roof Board NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 65 of 74 NNEMOjetc. BONDEDTABLE 6D: GYPSUM DECKS—REROOF(TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, ROOF COVER System Deck Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Base Fasteners(Note 11) Attach Base Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: Existing sound gypsum Trufast Twin Loc-Nail Assembled 6-inch o.c.at the 4-inch lap and 10-inch o.c.in two(2), G-34. or sum lank Flintlastic SA NailBase Fastener Field W D>80 Ibf a uall spaced,staggered center rows SBS SA SBS SA 60.0 gypsum p ( / ) q Y p gg G-35. Existing sound gypsum Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled 9-inch o.c.at the 4-inch lap and 9-inch o.c.in two(2), SBS-SA SBS-SA -60.0 or gypsum plank Fastener(Field W/D>88 Ibf) equally spaced,staggered center rows CONVENTIONAL SYSTEMS: Trufast FM-75 or FM-90 Base G-36. Existing sound gypsum All Weather/Empire Base; Sheet Fastener or Twin Loc-Nail 9-inch o.c.at the 4-inch lap and 18-inch o.c.in two(2), BP-AA or SBS- SBS-AA -45.0* or gypsum plank Yosemite Venting Base Assembled Fastener(Field W/D> equally spaced,staggered center rows AA 1001 bf) Existing sound gypsum Glasbase;Flexiglas Base;Flintlastic Trufast Twin Loc-Nail Assembled 6-inch o.c.at the 4-inch lap and 10-inch o.c.in two(2), BP-AA or SBS- SBS-AA,SBS- G-37. Base 20;All Weather/Empire Base -60.0 or gypsum plank Fastener(Field W/D>80 Ibf) equally spaced,staggered center rows AA TA or APP-TA or Yosemite Venting Base Glasbase;Flexiglas Base;Flintlastic Existing sound gypsum Trufast Twin Loc-Nail Assembled 9-inch o.c.at the 4-inch lap and 9-inch o.c.in two(2), BP-AA or SBS- SBS-AA,SBS- G-38. or sum lank Base 20;All Weather/Empire Fastener Field W/D>100 Ibf equally spaced,staggered center rows AA TA or APP-TA -67.5 gypsum p Base;Yosemite Venting Base ( / ) q Y p gg NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 66 of 74 NNEMOjetc. BONDEDTABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Substrate(Notes 1&12) Attach Attach MDP No. Type Type Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) SELF-ADHERING SYSTEMS: Min.0.25-inch DensDeck primed R-1 Existing fully bonded BUR or with FlintPrime or FlintPrime SA;or HA None N/A SBS-SA (Optional)SBS-SA SBS-SA -105.0 modified bitumen roof cover SECUROCK Gypsum-Fiber Roof Board. Min.1.5-inch ACFoam II,FlintBoard Min.0.25-inch DensDeck primed R 2 Existing fully bonded BUR or ISO,ENRGY 3,H-Shield or Multi- HA with FlintPrime or FlintPrime SA;or HA SBS-SA (Optional)SBS-SA SBS-SA -105.0 modified bitumen roof cover Max FA3 SECUROCK Gypsum-Fiber Roof Board. Existing fully bonded,smooth Min.0.25-inch DensDeck primed R-3 surface BUR or modified with FlintPrime or FlintPrime SA or A-PD,6- None N/A SBS-SA (Optional)SBS-SA SBS-SA -105.0 bitumen SECUROCK Gypsum-Fiber Roof inch o.c. Board R 4 Existing fully bonded,mineral Min.0.25-inch SECUROCK Gypsum- A-PD,6- None N/A SBS-SA (Optional)SBS-SA SBS-SA -172.5 surface modified bitumen Fiber Roof Board inch o.c. R-5 Existing fully bonded,mineral Min.0.25-inch DensDeck primed A-PD,6- None SBS-SA 180.0 N A surface modified bitumen with FlintPrime or FlintPrime SA inch o.c. / (Optional)SBS SA SBS SA Existing fully bonded,smooth Min.1.5-inch ACFoam II, Min.0.25-inch DensDeck primed R-6 surface BUR or modified FlintBoard,ENRGY 3 or Multi-Max A-PD,6- with FlintPrime or FlintPrime SA or A-PD,6- SBS-SA (Optional)SBS-SA SBS-SA -52.5 bitumen FA3 inch o.c. SECUROCK Gypsum-Fiber Roof inch o.c. Board Existing fully bonded,mineral Min.1.5-inch ACFoam II, Min.0.25-inch DensDeck primed R-7 surface BUR or modified FlintBoard,ENRGY 3 or Multi-Max A-PD,6- with FlintPrime or FlintPrime SA or A-PD,6- SBS-SA (Optional)SBS-SA SBS-SA -172.5 bitumen FA3 inch o.c. SECUROCK Gypsum-Fiber Roof inch o.c. Board Min.0.25-inch DensDeck primed R 8 Existing fully bonded BUR or Min.1.5-inch ACFoam II, M-OSFA with FlintPrime or FlintPrime SA or M-OSFA SBS-SA (Optional)SBS-SA SBS-SA -157.5 modified bitumen roof cover FlintBoard,ENRGY 3 or H-Shield SECUROCK Gypsum-Fiber Roof Board Existing fully bonded,smooth- Min.0.25-inch SECUROCK Gypsum- R-9 or granule-surface BUR or Fiber Roof Board M-PG1 None N/A SBS-SA (Optional)SBS-SA SBS-SA -172.5 modified bitumen Existing fully bonded,smooth- Min.0.25-inch DensDeck primed R-10 or granule-surface BUR or with FlintPrime or FlintPrime SA M-PG1 None N/A SBS-SA (Optional)SBS-SA SBS-SA -180.0 modified bitumen R-11 Existing fully bonded BUR or Min.1.5-inch ACFoam II, M-PG1 Min.0.25-inch SECUROCK Gypsum- M-PG1 SBS-SA (Optional)SBS-SA SBS-SA -172.5 modified bitumen roof cover FlintBoard,ENRGY 3 or H-Shield Fiber Roof Board NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 67 of 74 NNEMOjetc. BONDEDTABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, Base Insulation Layer Attach Top Insulation Layer Attach Roof Cover(Note 15) System Substrate(Notes 1&12) MDP No. Type (Notes 6,7,8) (Notes 6,7,8)Type Base Ply Ply Cap Ply (psf) Existing fully bonded BUR or Min.1.5-inch ACFoam II, Min.0.25-inch DensDeck primed R-12 modified bitumen roof cover Fli FAntBoard,ENRGY 3 or Multi-Max M-PG1 with FlintPrime or FlintPrime SA M-PG1 SBS-SA (Optional)SBS-SA SBS-SA -180.0 Existing fully bonded,smooth- Min.0.25-inch DensDeck primed R-13 or granule-surface BUR or with FlintPrime or FlintPrime SA or OB500 None N/A SBS-SA (Optional)SBS-SA SBS-SA -120.0 modified bitumen SECUROCK Gypsum-Fiber Roof Board Min.0.25-inch DensDeck primed R-14 Existing fully bonded BUR or Min.1.5-inch ACFoam II,FlintBoard OB500 with FlintPrime or FlintPrime SA or OB500 SBS-SA (Optional)SBS-SA SBS-SA -120.0 modified bitumen roof cover ISO or ENRGY 3 SECUROCK Gypsum-Fiber Roof Board Existing fully bonded,smooth- R-15 or granule-surface BUR or Min.0.25-inch SECUROCK Gypsum- ICP BOARD- None SBS-SA 172.5 N A granule-surface modified Fiber Roof Board MAX / (Optional)SBS-SA SBS-SA bitumen Existing fully bonded,smooth- or granule-surface BUR or Min.0.25-inch DensDeck primed ICP BOARD- R-16 None N/A SBS-SA (Optional)SBS-SA SBS-SA -192.5 granule-surface modified with FlintPrime or FlintPrime SA MAX bitumen Existing fully bonded,smooth- Min.1.0-inch ISO 95+GL,H-Shield, or granule-surface BUR or H-Shield CG,ENRGY 3 or min.1.3- ICP BOARD- Min.0.25-inch SECUROCK Gypsum- ICP BOARD- R-17 granule-surface modified inch ACFoam III,Min.1.5-inch MAX Fiber Roof Board MAX SBS-SA (Optional)SBS-SA SBS-SA 172.5 bitumen Multi-Max FA3 or Ultra-Max Existing fully bonded,smooth- Min.1.0-inch ISO 95+GL,H-Shield, or granule-surface BUR or H-Shield CG,ENRGY 3 or min.1.3- ICP BOARD- Min.0.25-inch DensDeck primed ICP BOARD- R-18 SBS-SA (Optional)SBS-SA SBS-SA -192.5 granule-surface modified inch ACFoam III,Min.1.5-inch MAX with FlintPrime or FlintPrime SA MAX bitumen Multi-Max FA3 or Ultra-Max Existing fully bonded,smooth- Min.0.25-inch SECUROCK Gypsum- R-19 or granule-surface BUR or Fiber Roof Board CR-20 None N/A SBS-SA (Optional)SBS-SA SBS-SA -172.5 modified bitumen Existing fully bonded,smooth- R-20 or granule-surface BUR or Min.FlintPrime or FlintPrime SA nch DensDeck primed F with FlintP CR-20 None N/A SBS-SA (Optional)SBS-SA SBS-SA -192.5 modified bitumen Min.1.0-inch ISO 95+GL,H-Shield, Existing fully bonded BUR or H-Shield CG,ENRGY 3 or min.1.3- CR-20 Min.0.2S-inch SECUROCK Gypsum 172.5 R-21 modified bitumen roof cover inch ACFoam III,Min.1.5-inch Fiber Roof Board CR-20 SBS-SA (Optional)SBS-SA SBS-SA Multi-Max FA3 or Ultra-Max NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEIVIO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 68 of 74 NNEMOjetc. BONDEDTABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, Base Insulation Layer Attach Top Insulation Layer Attach Roof Cover(Note 15) System Substrate(Notes 1&12) MDP No. Type (Notes 6,7,8) (Notes 6,7,8)Type Base Ply Ply Cap Ply (psf) Min.1.0-inch ISO 95+GL,H-Shield, R 22 Existing fully bonded BUR or H-Shield CG,ENRGY 3 or min.1.3- CR-20 Min.0.25-inch DensDeck primed CR-20 SBS-SA (Optional)SBS-SA SBS-SA -192.5 modified bitumen roof cover inch ACFoam III,Min.1.5-inch With FlintPrime or FlintPrime SA Multi-Max FA3 or Ultra-Max HYBRID SYSTEMS: R-23 Existing fully bonded BUR or Min.0.25-inch SECUROCK Gypsum- HA None N/A SBS-SA-H (Optional)SBS-AA, SBS-AA,SBS- -105.0 modified bitumen roof cover Fiber Roof Board SBS-TA,APP-TA TA,APP-TA Existing fully bonded,smooth Min.0.25-inch SECUROCK Gypsum- A-PD,6- (Optional)SBS-AA, SBS-AA,SBS- R-24 surface BUR or modified Fiber Roof Board inch o.c. None N/A SBS-SA-H SBS-TA,APP-TA TA,APP-TA 105.0 bitumen Existing fully bonded,mineral Min.0.25-inch SECUROCK Gypsum- A-PD,6- (Optional)SBS-AA, SBS-AA,SBS- R-25 surface modified bitumen Fiber Roof Board inch o.c. None N/A SBS-SA-H SBS-TA,APP-TA TA,APP-TA 180.0 Existing fully bonded,smooth- Min.0.25-inch SECUROCK Gypsum- (Optional)SBS-AA, SBS-AA,SBS- R-26 or granule-surface BUR or Fiber Roof Board M-PG1 None N/A SBS-SA-H SBS-TA,APP-TA TA,APP-TA -180.0 modified bitumen Existing fully bonded,smooth- Min.0.25-inch SECUROCK Gypsum- (Optional)SBS-AA, SBS-AA,SBS- R-27 or granule-surface BUR or Fiber Roof Board OB500 None N/A SBS-SA-H SBS-TA,APP-TA TA,APP-TA -120.0 modified bitumen Existing fully bonded,smooth- or granule-surface BUR or Min.0.25-inch SECUROCK Gypsum- ICP BOARD- (Optional)SBS-AA, SBS-AA,SBS- R 28 granule-surface modified Fiber Roof Board MAX None N/A SBS-SA-H SBS-TA,APP-TA TA,APP-TA 195.0 bitumen Existing fully bonded,smooth- Min.0.25-inch SECUROCK Gypsum- (Optional)SBS-AA, SBS-AA,SBS- R-29 or granule-surface BUR or Fiber Roof Board CR-20 None N/A SBS-SA-H SBS-TA,APP-TA TA,APP-TA 195.0 modified bitumen CONVENTIONAL SYSTEMS: modified bitumen roof cover 0.5-inch Structodek High Density AA (Optional)BP-AA, TA or APP-TA Existing fully bonded BUR or BP-AA,SBS- SBS-AA,SBS- R-30 Fiberboard or min.0.75-inch Fesco HA None N/A SBS-AA,SBS-TA or -105.0 Board(homogeneous) APP-TA 0.25-inch DensDeck,DensDeck BP-AA,SBS- (Optional)BP-AA, R-31 Existing fully bonded BUR or Prime or SECUROCK Gypsum-Fiber HA None N/A AA,SBS-TA SBS-AA,SBS-TA or SBS-AA,A,SBS-APP-TA modified bitumen roof cover TA or 105.0 Roof Board or APP-TA APP-TA Min.1.5-inch ACFoam II,FlintBoard Min.0.5-inch Structodek High (Optional)BP-AA, Existing fully bonded BUR or Density Fiberboard,Min.0.75-inch BP-AA or SBS-AA,SBS- R-32 modified bitumen roof cover Ma x FA3 ENRGY 3,H-Shield or Multi- HA FescoBoard(homogeneous)or Min. HA SBS AA APP-TA SBS-AA,SBS-TA or TA or APP-TA 105.0 Ma 0.5-inch DuraBoard(homogeneous) NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEIVIO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 69 of 74 NNEMOjetc. BONDEDTABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, Base Insulation Layer Attach Top Insulation Layer Attach Roof Cover(Note 15) System Substrate(Notes 1&12) MDP No. Type (Notes 6,7,8) (Notes 6,7,8)Type Base Ply Ply Cap Ply (psf) Min.1.5-inch ACFoam II,FlintBoard Min.0.25-inch SECUROCK Gypsum- BP-AA,SBS- (Optional)BP-AA, R-33 Existing fully bonded BUR or ISO,ENRGY 3,H-Shield or Multi- HA Fiber Roof Board,DensDeck, HA AA,SBS-TA SBS-AA,SBS-TA or SBS-AA,SBS-APP-TA modified bitumen roof cover TA or 105.0 Max FA3 DensDeck Prime or APP-TA APP-TA Existing fully bonded,smooth (Optional)BP-AA, Min.0.5-inch Structodek High A-PD,6- BP-AA,SBS- SBS-AA,SBS- R-34 surface BUR or modified Density Fiberboard inch o.c. None N/A AA SBS-AA,SBS-TA or TA or APP-TA -105.0 bitumen APP-TA Existing fully bonded,mineral Min.0.5-inch Structodek High A-PD,6- BP-AA,SBS- (Optional)BP-AA, SBS-AA,SBS- R-35 surface modified bitumen Density Fiberboard inch o.c. None N/A AA SBS-AA,SBS-TA or TA or APP-TA -180.0 APP-TA Existing fully bonded,smooth Min.0.25-inch DensDeck, BP-AA,SBS- (Optional)BP-AA, R-36 surface BUR or modified DensDeck Prime or SECUROCK PD,._ TA or None N/A AA,SBS-TA SBS-AA,SBS-TA or SBS-AA,SBS-APP-TA inch o. 105.0 bitumen Gypsum-Fiber Roof Board c. or APP-TA APP-TA Min.0.25-inch DensDeck, BP-AA,SBS- (Optional)BP-AA, R-37 Existing fully bonded,mineral DensDeck Prime or SECUROCK PD,. TA or None N/A AA,SBS-TA SBS-AA,SBS-TA or SBS-AA,SBS-APP-TA i surface modified bitumen inch o. 180.0 Gypsum-Fiber Roof Board c. or APP-TA APP-TA Existing fully bonded,smooth ,(Optional)BP-AA Min.1.5-inch ACFoam II,FlintBoard A-PD,6- Min.0.5-inch Structodek High A-PD,6- BP-AA or SBS-AA,SBS- R-38 surface BUR or modified ISO,ENRGY 3 or H-Shield inch o.c. Density Fiberboard inch o.c. SBS-AA SBS-AA,SBS-TA or TA or APP-TA -52.5 bitumen APP-TA BP-AA or Existing fully bonded,smooth (Optional)BP-AA, Min.2-inch ACFoam ll,FlintBoard A-PD,6- Min.0.25-inch SECUROCK Gypsum- A-PD,6- SBS-AA, SBS-AA,SBS- R-39 surface BUR or modified ISO,ENRGY 3 or H-Shield inch o.c. Fiber Roof Board or DensDeck inch o.c. SBS-TA or SBS-AA,SBS TA or TA or APP-TA 52.5 bitumen APP-TA APP TA Existing fully bonded,mineral (Optional)BP-AA, R-40 surface BUR or modified Min.1.5-inch ACFoam II,FlintBoard A-PD,6- Min.0.5-inch Structodek High A-PD,6- BP-AA or SBS-AA,SBS-TA or SBS-AA,SBS- _172.5 bitumen ISO,ENRGY 3 or H-Shield inch o.c. Density Fiberboard inch o.c. SBS-AA APP TA TA or APP-TA Existingfull bonded,mineral BP-AA or y (Optional)BP-AA, R-41 surface BUR or modified Min.2-inch ACFoam II,FlintBoard A-PD,6- Min.0.25-inch SECUROCK Gypsum- A-PD,6- SBS-AA, SBS-AA,SBS-TA or SBS-AA,SBS- -172.5 bitumen ISO,ENRGY 3 or H-Shield inch o.c. Fiber Roof Board or DensDeck inch o.c. SBS-TA or APP-TA TA or APP-TA APP-TA Existing fully bonded BUR or Min.1.5-inch ACFoam II,FlintBoard Min.0.5-inch Structodek High BP-AA or (Optional)BP-AA, SBS-AA,SBS- R-42 modified bitumen roof cover ISO,ENRGY 3 or H-Shield M-OSFA Density Fiberboard M-OSFA SBS AA SBS-AA,SBS-TA or TA or APP-TA -127.5 APP-TA BP-AA or (Optional)BP-AA, M-OSFA Existing fully bonded BUR or Min.1.5-inch ACFoam II,FlintBoard Min.0.25-inch SECUROCK Gypsum- SBS-AA, SBS-AA,SBS R-43 modified bitumen roof cover ISO,ENRGY 3 or H-Shield Fiber Roof Board or DensDeck M OSFA SBS-TA or SBS-AA,SBS-TA or TA or APP-TA 157.5 APP-TA APP-TA NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-1124 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 70 of 74 NNEMOjetc. BONDEDTABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, Base Insulation Layer Attach Top Insulation Layer Attach Roof Cover(Note 15) System Substrate(Notes 1&12) MDP No. Type (Notes 6,7,8) (Notes 6,7,8)Type Base Ply Ply Cap Ply (psf) Existing fully bonded,smooth- (Optional)BP-AA, Min.0.5-inch Structodek High BP-AA,SBS- SBS-AA,SBS- R-44 or granule-surface BUR or Density Fiberboard M-PG1 None N/A AA SBS-AA,SBS-TA or TA or APP-TA 180.0 modified bitumen APP-TA Existing fully bonded,smooth- Min.0.25-inch DensDeck Prime or BP-AA,SBS- (Optional)BP-AA, SBS-AA,SBS- R-45 or granule-surface BUR or SECUROCK Gypsum-Fiber Roof M-PG1 None N/A AA,SBS-TA SBS-AA,SBS-TA or 180.0 modified bitumen Board or APP-TA APP-TA TA or APP-TA Existing fully bonded BUR or Min.1.5-inch ACFoam II,FlintBoard Min.0.5-inch Structodek High BP-AA or (Optional)BP-AA, SBS-AA,SBS- R-46 modified bitumen roof cover ISO,ENRGY 3 or H-Shield M-PG1 Density Fiberboard M-PG1 SBS-AA SBS-AA,SBS-TA or TA or APP-TA -180.0 APP-TA BP-AA or (Optional)BP-AA, M-PG1 Existing fully bonded BUR or Min.1.5-inch ACFoam II,FlintBoard Min.0.25-inch SECUROCK Gypsum- SBS-AA, SBS-AA,SBS R 47 modified bitumen roof cover ISO,ENRGY 3 or H-Shield Fiber Roof Board or DensDeck M-PG1 SBS-TA or SBS-AA,SBS-TA or TA or APP-TA 180.0 APP-TA APP-TA Existing fully bonded,smooth- Min. _ (Optional)BP-AA, R-48 or granule-surface BUR or ty Fiberboard inch Structodek High OB500 None N/A BP AA,SBS SBS-AA,SBS-TA or SBS TA or r A,SBS-APP-TA Density F -120.0 modified bitumen APP-TA Existing fully bonded,smooth- Min.0.25-inch SECUROCK Gypsum- BP-AA,SBS- (Optional)BP-AA, SBS-AA,SBS- R-49 or granule-surface BUR or Fiber Roof Board OB500 None N/A AA,SBS-TA SBS-AA,SBS-TA or TA or APP-TA 120.0 modified bitumen or APP-TA APP-TA R-50 Existing fully bonded BUR or Min.1.5-inch ACFoam II,FlintBoard OB500 Min.0.5-inch Structodek High OB500 BP-AA or (Optional)BP-AA,SBS-AA,SBS-TA or SBS-AA,SBS- _120.0 modified bitumen roof cover ISO,ENRGY 3 or H-Shield Density Fiberboard SBS-AA APP TA TA or APP-TA Min.0.25-inch SECUROCK Gypsum- BP-AA,SBS- (Optional)BP-AA, R-51 Existing fully bonded BUR or Min.1.ENRGY 3 or H-Shield ACFoam II,FlintBoard OB500 Fiber Roof Board,DensDeck or OB500 AA,SBS-TA SBS-AA,SBS-TA or SBS-TA or rA,SBS-APP-TA 120.0 modified bitumen roof cover ISO,ENRRGY 3 DensDeck Prime or APP-TA APP-TA Existing fully bonded,smooth- Min. (Optional)BP-AA, SBS-AA,R-52 or granule-surface BUR or ty Fiberboard inch Structodek High CR-20 None N/A AA BP-AA,SBS- SBS-AA,SBS-TA or TA or r SBS-APP-TA Density F -195.0 modified bitumen APP TA Existing fully bonded,smooth- BP-AA,SBS- (Optional)BP-AA, or granule-surface BUR or Min.0.25-inch SECUROCK Gypsum- ICP BOARD- SBS-AA,SBS- R-53 granule-surface modified Fiber Roof Board MAX None N/A AA,SBS-TA SBS-AA,SBS-TA or TA or APP-TA 195.0 bitumen or APP-TA APP TA Existing fully bonded,smooth- Min.1.0-inch ISO 95+GL,H-Shield, or granule-surface BUR or H-Shield CG,ENRGY 3 or min.1.3- ICP BOARD- Min.0.25-inch DensDeck or ICP BOARD- R-54 granule-surface modified inch ACFoam III,Min.1.5-inch MAX DensDeck Prime MAX SBS-TA (Optional)SBS-TA SBS-TA 180.0 bitumen Multi-Max FA3 or Ultra-Max NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 71 of 74 NNEMOjetc. BONDEDTABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, Base Insulation Layer Attach Top Insulation Layer Attach Roof Cover(Note 15) System Substrate(Notes 1&12) MDP No. Type (Notes 6,7,8) (Notes 6,7,8)Type Base Ply Ply Cap Ply (psf) Existing fully bonded,smooth- Min.1.0-inch ISO 95+GL,H-Shield, Min.0.5-inch Structodek High (Optional)BP-AA, or granule-surface BUR or H-Shield CG,ENRGY 3 or min.1.3- ICP BOARD- Density Fiberboard or DuraBoard ICP BOARD- BP-AA or SBS-AA,SBS- R-55 granule-surface modified inch ACFoam III,Min.1.5-inch MAX (homogeneous)or min.1.5-inch MAX SBS-AA SBS-AA,SBS-TA or TA or APP-TA 180.0 bitumen Multi-Max FA3 or Ultra-Max FescoBoard(laminated) APP TA Existing fully bonded,smooth- Min.1.0-inch ISO 95+GL,H-Shield, (Optional)BP-AA, or granule-surface BUR or H-Shield CG,ENRGY 3 or min.1.3- ICP BOARD- Min.0.25-inch SECUROCK Gypsum- ICP BOARD- BP-AA or SBS-AA,SBS- R-56 granule-surface modified inch ACFoam III,Min.1.5-inch MAX Fiber Roof Board MAX SBS-AA SBS-AA,SBS-TA or TA or APP-TA 225.0 bitumen Multi-Max FA3 or Ultra-Max APP TA Existing fully bonded,smooth- Min.1.0-inch ISO 95+GL,H-Shield, or granule-surface BUR or H-Shield CG,ENRGY 3 or min.1.3- ICP BOARD- Min.0.25-inch SECUROCK Gypsum- ICP BOARD- SBS-TA or (Optional)SBS-TA SBS-TA or R-57 232.5 granule-surface modified inch ACFoam III,Min.1.5-inch MAX Fiber Roof Board MAX APP-TA or APP-TA APP-TA bitumen Multi-Max FA3 or Ultra-Max Existing fully bonded,smooth- Min.1.0-inch ISO 95+GL,H-Shield, (Optional)BP-AA, Min or granule-surface BUR or H-Shield CG,ENRGY 3 or min.1.3- ICP BOARD- ICP BOARD- BP-AA or SBS-AA,SBS- R-58 granule-surface modified inch ACFoam III,Min.1.5-inch MAX .0.25-inch DensDeck MAX SBS-AA SBS-AA,SBS-TA or TA or APP-TA 240.0 bitumen Multi-Max FA3 or Ultra-Max APP-TA Existing fully bonded,smooth- BP-AA,SBS- (Optional)BP-AA, R-59 or granule-surface BUR or Min.0.25-inch SECUROCK Gypsum CR-20 None N/A AA,SBS-TA SBS-AA,SBS-TA or SBS rA,SBS-APP TA Fiber Roof Board TA or 195.0 modified bitumen or APP-TA APP-TA Min.1.0-inch ISO 95+GL,H-Shield, R-60 Existing fully bonded BUR or H-Shield CG,ENRGY 3 or min.1.3- CR-20 Min.0.25-inch DensDeck or CR-20 SBS-TA (Optional)SBS-TA SBS-TA -180.0 modified bitumen roof cover inch ACFoam III,Min.1.5-inch DensDeck Prime Multi-Max FA3 or Ultra-Max Min.1.0-inch ISO 95+GL,H-Shield, Min.0.5-inch Structodek High (Optional)BP-AA, Existing fully bonded BUR or H-Shield CG,ENRGY 3 or min.1.3- Density Fiberboard or DuraBoard BP-AA or SBS-AA,SBS R-61 modified bitumen roof cover inch ACFoam III,Min.1.5-inch CR-20 CR-20 SBS-AA,SBS-TA or 180.0 (homogeneous)or min.1.5-inch SBS-AA APP TA TA or APP-TA Multi-Max FA3 or Ultra-Max FescoBoard(laminated) Min.1.0-inch ISO 95+GL,H-Shield, (Optional)BP-AA, CR-20 CR-20 Existing fully bonded BUR or H-Shield CG,ENRGY 3 or min.1.3- Min.0.25-inch SECUROCK Gypsum- BP-AA or SBS-AA,SBS R-62 modified bitumen roof cover inch ACFoam III,Min.1.5-inch Fiber Roof Board SBS AA SBS-AA,SBS-TA or TA or APP-TA 225.0 Multi-Max FA3 or Ultra-Max APP-TA Min.1.0-inch ISO 95+GL,H-Shield, Existing fully bonded BUR or H-Shield CG,ENRGY 3 or min.1.3- CR 20 Min.0.25-inch SECUROCK Gypsum- CR 20 SBS-TA or (Optional)SBS-TA SBS-TA or 232.5 R 63 modified bitumen roof cover inch ACFoam III,Min.1.5-inch Fiber Roof Board APP-TA or APP-TA APP-TA Multi-Max FA3 or Ultra-Max NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NElvlo ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 72 of 74 NNEMOjetc. BONDEDTABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, Base Insulation Layer Attach Top Insulation Layer Attach Roof Cover(Note 15) System Substrate(Notes 1&12) MDP No. Type (Notes 6,7,8) (Notes 6,7,8)Type Base Ply Ply Cap Ply (psf) Min.1.0-inch ISO 95+GL,H-Shield, (Optional)BP-AA, Existing fully bonded BUR or H-Shield CG,ENRGY 3 or min.1.3- BP-AA or SBS-AA,SBS- R-64 modified bitumen roof cover inch ACFoam III,Min.1.5-inch CR-20 Min.0.25-inch DensDeck CR-20 SBS-AA SBS-AA,SBS-TA or TA or APP-TA 240.0 Multi-Max FA3 or Ultra-Max APP TA COLD-APPLIED SYSTEMS: Existing fully bonded BUR or (Optional)Min.0.5-inch ACFoam II, Min.1.5-inch ACFoam III,FlintBoard R-65 modified bitumen roof cover FlintBoard ISO,H-Shield,FlintBoard OB500 Iso Cold,H-Shield CG or FlintBoard OB500 SBS-CA1 None SBS-CA1 -82.5 ISOH ISO ColdH Existing fully bonded BUR or (Optional)Min.0.5-inch ACFoam II, Min.1.5-inch ACFoam III,FlintBoard R-66 modified bitumen roof cover FlintBoard ISO,H-Shield,FlintBoard CR-20 Iso Cold,H-Shield CG or FlintBoard CR-20 SBS-CA1 None SBS-CA1 -82.5 ISOH Iso ColdH Existing fully bonded,smooth- Min.0.25-inch SECUROCK Gypsum- A-PD,6- R-67 or granule-surface BUR or Fiber Roof Board inch o.c. None N/A SBS-CA1 None SBS-CA1 -105.0 modified bitumen Existing fully bonded,smooth Min.0.5-inch ACFoam II,FlintBoard A-PD,6- Min.0.25-inch SECUROCK Gypsum- A-PD,6- R-68 surface BUR or modified ISO,H-Shield,FlintBoard ISOH inch o.c. Fiber Roof Board inch o.c. SBS-CA1 None SBS-CA1 -52.5 bitumen Existing fully bonded,mineral Min.0.5-inch ACFoam II,FlintBoard A-PD,6- Min.0.25-inch SECUROCK Gypsum- A-PD,6- R-69 surface BUR or modified ISO,H-Shield,FlintBoard ISOH inch o.c. Fiber Roof Board inch o.c. SBS-CA1 None SBS-CA1 -105.0 bitumen Existing fully bonded,smooth- Min.0.25-inch SECUROCK Gypsum- R-70 or granule-surface BUR or Fiber Roof Board M-PG1 None N/A SBS-CA1 None SBS-CA1 -105.0 modified bitumen Existing fully bonded,mineral Min.0.5-inch ACFoam II,FlintBoard M-OSFA, Min.0.25-inch SECUROCK Gypsum- M-OSFA, R-71 surface BUR or modified ISO,H-Shield,FlintBoard ISOH M-PG1 Fiber Roof Board M-PG1 SBS-CA1 None SBS-CA1 -105.0 bitumen Existing fully bonded,smooth- Min.0.25-inch SECUROCK Gypsum- R-72 or granule-surface BUR or Fiber Roof Board OB500 None N/A SBS-CA1 None SBS-CA1 -105.0 modified bitumen Existing fully bonded,mineral Min.0.5-inch ACFoam II,FlintBoard Min.0.25-inch SECUROCK Gypsum- R-73 surface BUR or modified ISO,H-Shield,FlintBoard ISOH OB500 Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -105.0 bitumen Existing fully bonded,smooth- (Optional)Min.0.5-inch ACFoam II, or granule-surface BUR or ICP BOARD- Min.0.25-inch SECUROCK Gypsum- ICP BOARD- R 74 granule-surface modified SOH FlintBoard ISO,H-Shield,FlintBoard MAX Fiber Roof Board MAX SBS-CAl None SBS CA1 105.0 ISOH SOH NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NElvlo ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 73 of 74 NNEMOjetc. BONDEDTABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, .. Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Substrate(Notes 1&12) Type Attach Type Attach Base Ply Ply Cap Ply pD) (Notes 6,7,8) (Notes 6,7,8) Existing fully bonded,smooth- Min.0.25-inch SECUROCK Gypsum- R-75 or granule-surface BUR or Fiber Roof Board CR-20 None N/A SBS-CA1 None SBS-CA1 -105.0 modified bitumen Existing fully bonded,mineral Min.0.5-inch ACFoam II,FlintBoard Min.0.25-inch SECUROCK Gypsum- R-76 surface BUR or modified ISO,H-Shield,FlintBoard ISOH CR-20 Fiber Roof Board CR-20 SBS-CA1 None SBS-CA1 -105.0 bitumen TABLE7B: RECOVER APPLICATIONS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) jaw SYSTEM TYPE F:NON-INSULATED,BONDED ROOFCOVER System Substrate Primer Roof Cover(Note 15) MDP(psf) No. (Notes 1&12) Base Ply Ply Cap Ply R-77 Existing fully bonded BUR over structural concrete deck (Optional)FlintPrime SBS-CA1 None SBS-CA1 -187.5 NEMO ETC,LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION Revision 25:07/20/2020 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems;(610)893-5400 Appendix 1,Page 74 of 74