Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET ST. LU C I E WORKS o ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code- Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A, B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B,C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6.7 Metal Roofs A, B, D 1,2,3,4,5,6,7 Wood Shingles and A, B, D 1,2,4,5,6,7 Shakes Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3, Design Calculations per Chapter 16,or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18,2021 5T. LUCI E Section A (General Information) Master Permit No. Process No. Contractors Name: License# Job Address ROOF CATEGORY ❑Low Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles ❑Asphaltic Shingles ❑Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance ❑ Reroofing ❑Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. 1 . I � j M , TM Premium Report e a I e V i e 7/1/2021 IIIII� LENGTH DIAGRAM Total Line Lengths: Valleys = 157 ft Flashing = 23 ft Ridges = 154 ft Rakes = 13 ft Step flashing = 47 ft Hips = 232 ft Eaves = 394 ft Parapets = 0 ft 63 N N 16 i m 1`5 'J1 J i�^ 10 -'' Z6 a +g 0 rn Q 14 xy N -----------------------_ ;M c co:; � 1 � o i. o � i m �Lin 7\ d % 26 w � o -------------------- � N - O \ �9 \• i N 18 26 A; 79 E 12 s 52 13 N s w Note: This diagram contains segment lengths(rounded to the nearest whole number)over 5.0 Feet. In some cases, segment labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9). ©2008-2021 Eagle View Technologies,Inc.and Pictometry International Corp.—All Rights Reserved—Protected by European Patent Application No.10162199.3—Covered by one or more of U.S.Patent Nos.8,078,436;8,145,578;8,170,940; 8,209,152;8,515,125;8,825,454;9,135,737;8,670,961;9,514,568;8,818,770;8,542,880;9,244,589;9,329,749;9,599,466.Other Patents Pending. PAGE 4 Section D (Steep Slope Roof System) Tamko Building Products Roof System Manufacturer: Notice of Acceptance Number: FL18355.1 Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations): Zone 1: Zone 2e: Zone 2n: Zone 2r: Zone 3e: Zone 3r: Deck Type: 5/g plywood Type Underlayment: ASTM #30 D226 Type 2 Roof Slope: 3 : 121 Insulation: N/A Fire Barrier: N/A Ridge Ventilation? Fastener Type&Spacing: 1-1/4"RS Nail TOC Lap,2 Rows @12'OC Field N/A Adhesive Type: Self Adhered Type Cap Sheet: Weatherlock I Mean Roof-Height: 12 Roof Covering: Heritage Type&Size Drip 3"Face 26GA @41'OC Edge: vc 1�.;tea Section C (Low Slope Roof) Surfacing: N/A Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment: manufacturer Zone 1':N/A' oc @ Lap,#Rows N/A@ N/At'oe (If a component is not used,identify as"NA") Zone 1&ZA" oc @ Lap,#Rows N/A @ N-LA—"oc System Manufacturer: Certainteed Zone 2N—/A" oc @ Lap,#Rows NZA @ N�A"oc Product Approval No.: FL2533-R24 #W-107 Zone 3:-NZA' oc @ Lap,#RowsNIA @ N-1A'oc Number of Fasteners Per Insulation Board: Design Wind Pressures,From RAS 128 Or Calculations: Zone 1':N/A Zone 1:N/A Zone 2:-NLA.Zone 3: N/A Zone 1':-37 Zone 1:-64 Zone 2:-84.Zone 3: -1 15 Illustrate Components Noted and Details as Applicable: Max. Design Pressure, from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping, system: -127.5 Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing,Coping,Etc., Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base Type: 5/8 Plywood Flashing,Component Material,Material'Thickness,Fastener Type,Fastener Spacing or Submit Manufacturers Details that Gauge Thickness: N/A Comply with RAS 111 and Chapter 16.. Slope: 1/8 Anchor/Base Sheet&No.df Ply(s): N/A Primer: Flintprime FT. Anchor/Base Sheet Fastener/Bonding Material: N/A N/A Insulation Base Layer: N/A Base Insultation Size and Thickness: N/A Parapet Base Insulation Fastener/Bonding Material: Height Top Insulation Layer: N/A Top Insulation Size and Thickness: N/A FT. Top Insulation Fastener/Bonding Material: 12 N/A Mean Base Sheet(s)&No.of Ply(s): Flintlastic SA PI Base 1 ply Roof Base Sheet Fastener/Bonding Material: Height Self Adhered Ply Sheet(s)'&No.of Ply(s): N/A Ply Sheet Fastener/Bonding Material: N/A Top Ply: Flintlastic SA CAP Top Ply Fastener/Bonding Material: Self Adhered Edge Nailable Deck MIMIAM11- Miami-Dade County HVHZ Electronic Roof Permit Form M "Delivering Excellence Every Day" Illustrate Components Noted and Details as Applicable: Top Ply Irderplies Boise Sheet Roof Mean Height: ft. Drip Metal: 3"Face 26 GA Galvanized Metal Surfacing: - 1)1'il) Metal I N/A Top Ply: Flinlastic SA Cap Interplies: N/A �- Base Sheet: Roof deck Flintastic SA Nailbase Deck Type: 5/8 plywood