HomeMy WebLinkAboutEnergy CodeP
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 129 Phase 3 Waterstone 2000 BGR
Builder Name: ADAMS HOMES
Street: 5729 Waterstone Boulevard
Permit Office:
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�1941.1 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1428.20 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 288.56 ft2
c. Frame - Wood, Exterior
R=13.0 224.40 ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2084.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2004.00 ft2
6. Conditioned floor area above grade (ft2) 2004
b. Knee Wall (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(199.2 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 142.83 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 400.8
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 38.54 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: bbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 4.831 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average. SHGC: 0.268
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2004.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 59.97
Glass/Floor Area: 0.099
PASS
Total Baseline Loads: 61.29
I hereby certify that the plans apt9' cations covered
Revie&of the plans and
4Z8B S�^q?
this calculation are in complig c i erg
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: n4-98-2ro1 Winn Kanmany
this building will be inspected for
.. a
compliance with Section 553.908J
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Ete.
�
p
OWNER/AG�
BUILDING OFFICIAL:
l
DATE: - -
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
i Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/28/2021 12:03 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
-i
"FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 129 Phase 3 Waterstone Bedrooms: 4
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 2004
Lot #
129-3
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
5729 Waterstone Boule
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2004 18837.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2004 18837.6 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 181.9 ft 0
2004 ft2 ----
0.35 0 0.65
ROOF
/
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
#
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2241 ft2 502 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2004 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2004 ft2 0.11
Wood
2
Knee Wall (Vented).
Main 19 Blown
80 ft2 0.11
Wood
4/28/2021 12:03 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
'FORM R405-2020 INPUT SUMMARY CHFCKI IST RFPnRT
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing Solar Below
1 NW
Exterior Concrete Block - Int Insul Main
4.1 53 7 9
7
513.5 ft'
0
0 0.6
0
2 NE
Exterior Concrete Block - Int Insul Main
4.1 20 0 9
4
186.7 ft'
0
0 0.6
0
3 SE
Exterior Frame - Wood Main
13 25 2 8
11
224.4 ft2
0
0.23 0.6
0
4 SE
Exterior Concrete Block - Int Insul Main
4.1 39 0 9
4
364.0 ftZ
0
0 0.6
0
5 SW
Exterior Concrete Block - Int Insul Main
4.1 37 4 9
9
364.0 W
0 0.6
0
6 -
Garage Frame - Wood Main
13 30 11 9
4
288.6 ft'
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
- Wood Main
None
.25
2
8
6 8
17.8 ftZ
2
NE Insulated Main
None
.25
3
6 8
20 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
NW 1 Vinyl Low-E Double Yes
0.33 0.23 N
13.3 ftz
1 ft 5 in
0 ft 9 in
None
None
2
NW 1 Vinyl Low-E Double Yes
0.33 0.23 N
16.2 ft'
1 ft 5 in
0 ft 9 in
None
None
3
NE 2 Vinyl Low-E Double Yes
0.33 0.21 N
38.5 ft'
1 ft 5 in
4 ft 0 in
None
None
4
SE 3 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft'
1 ft 5 in
0 ft 9 in
None
None
5
SW 5 Vinyl Low-E Double Yes
0.55 0.7 N
17.8 ft'
11 ft 8 in
1 ft 0 in
None
None
6
SW 5 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft'
1 ft 5 in
0 ft 9 in
None
None
7
SW 5 Vinyl Low-E Double Yes
0.33 0.23 N
48.6 ft'
11 ft 8 in
0 ft 9 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
754 ft' 754 ft'
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000418 2197.7 120.57 226.36
.1348
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5
34.6 kBtu/hr
1
sys#1
4/28/2021 12:03 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4
"PORM R405-2020 INPUT Rl1MMARY rWFr..KI IRT RFPnPT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Sing[ SEER: 16
35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ftz
DUCTS
---- Supply ----
V
---- Return ---
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 400.8 ft
Main
100.2 ft Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
Heatinf X� Jan f Xi Feb
Mar
Mar
Apr
Apr f
May X Jun X Jul
May Jun 4 Jul
X Aug
f Aug
Se
SeP f
Oct
Oct
Nov
Dec
Dec
Ventin [ Jan [ ] Feb
X Mar
[X]
A r [
Ma Jun [ Jul
[ Au
Se [X
Oct
XNov
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78 80
80
80
80
PM
80
80
78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78
78 78
78
78
78
PM
78
78
78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft'
0 ft
0.3
Main
4/28/2021 12:03 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
5729 Waterstone Boulevard, Fort Pierce, FL, 34951
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftZ)
7. Windows-
Description
a. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.23
b. U-Factor:
Dbl, U=0.33
SHGC:
SHGC=0.21
c. U-Factor:
Dbl, U=0.55
SHGC:
SHGC=0.70
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights
Description
a. U-Factor(AVG):
N/A
SHGC(AVG):
N/A
New (From Plans)
10. Wall Type and Insulation
Detached
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
1
c. Frame -- Wood, Exterior
4
d. N/A
No
11. Ceiling Type and insulation level
a. Under Attic (Vented)
2004
b. Knee Wall (Vented)
Area
c. N/A
142.83 ftz
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Main, AH: Main
38.54 ftz
13. Cooling systems
17.78 ftz
a. Central Unit
ftZ
4.831 ft.
0.268
Area
ftZ
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ftZ
b. N/A R= ftZ
c. N/A R= ftZ
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on instalLed Code compliant features.
Builder Signature: Date:
Address of New HoffiW � City/FL Zip:
Insulation
Area
R=4.1
1428.20 ftZ
R=13.0
288.56 ftZ
R=13.0
224.40 ftZ
R=
ftZ
Insulation
Area
R=30.0
2004.00 ftZ
R=19.0
80.00 ftZ
R=
ftZ
R ftZ
6 400.8
kBtu/hr
Efficiency
35.0 SEER:16.00
kBtu/hr Efficiency
34.6 HSPF:8.50
Cap: 40 gallons
EF: 0.94
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/28/2021 12:03 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1