Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 29 Phase 3 Waterstone 2508 CRGR Builder Name: ADAMS HOMES Street: 8323 Amalfi Circle Permit Office: City, State, Zip: Fort Pierce, FL, 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�2020.7 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1748.70 ftz b. Frame - Wood, Adjacent R=13.0 272.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 4 d. N/A R= ftz 5. Is this a worst case? No 11. Ceiling Types (2603.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2523.00 ftz 6. Conditioned floor area above grade (ftz) 2523 b. Knee Wall (Vented) R=19.0 80.00 ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 7. Windows(293.4 sqft.) Description Area 12. Ducts R ftz a. Sup: Attic, Ret: Main, AH: Main 6 503.2 a. U-Factor: Dbl, U=0.33 166.06 ftz SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 ftz 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 42.0 SEER:15.00 c. U-Factor: Dbl, U=0.55 35.56 ftz SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 6.223 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.288 a. Electric Heat Pump 42.0 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ftz 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2523.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 16. Credits Pstat Total Proposed Modified Loads: 70.67 Glass/Floor Area: 0.116 PASS Total Baseline Loads: 71.58 I hereby certify that the plans cations covered. Revs of the plans and o�HE STq?� this calculation are in compli c the Flori rgy specifications covered by this ;y p Code. calculation indicates compliance with the Florida Energy Code. 0- PREPARED BY: Before construction is completed DATE: 116-ns-91191 Winn KPnmany this building will be inspected for compliance with Section 553.908 I herebycertify that this building, as designed, is in compliance fY 9, 9 P Florida Statutes. with the Florida e. G'Op-*rTL OWNER/ :l BUILDING OFFICIAL: DATE: DATE: _ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house. 6/8/2021 4:56 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 29 Phase 3 Waterstone 2 Bedrooms: 4 User Conditioned Area: 2523 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address 29-3 Waterstone 8323 Amalfi Circle St. Lucie Fort Pierce , FL, 34951 CLIMATE / V/ Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2523 22202.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2523 22202.4 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0 2523 ftz ---- 0.44 0 0.56 ROOF / V/ # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Barr Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Gable or Shed Composition shingles 2821 ft' 630 ft' Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2523 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 2523 ftz 0.11 80 ft, 0.11 Wood Wood 6/8/2021 4:56 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Int Insul Main 4.1 48 6 8 0 388.0 ftZ 0 0 0.6 0 2 E Exterior Concrete Block - Int Insul Main 4.1 37 2 8 0 297.3 ftZ 0 0 0.6 0 3 S Exterior Concrete Block - Int Insul Main 4.1 51 3 8 0 410.0 ftZ 0 0 0.6 0 4 SW Exterior Concrete Block - Int Insul Main 4.1 6 2 8 0 49.3 ftZ 0 0 0.6 0 5 W Exterior Concrete Block - Int Insul Main 4.1 37 6 8 0 300.0 ftZ 0 0 0.6 0 6 - Garage Frame - Wood Main 13 34 0 8 0 272.0 ftZ 0 0.23 0.01 0 7 W Exterior Concrete Block - Int Insul Main 4.1 23 6 8 0 188.0 ftZ 0 0 0.6 0 8 N Exterior Concrete Block - Int Insul Main 4.1 8 6 8 0 68.0 ftZ 0 0 0.6 0 9 S Exterior Concrete Block - Int Insul Main 4.1 6 0 8 0 48.0 ftZ 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Main None .25 3 6 8 20 ftZ 2 - Wood Main None .25 2 8 6 8 17.8 ftZ 3 S Insulated Main None .25 2 4 6 8 15.6 ftZ WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ftZ 25 ft 0 in 0 ft 10 in Drapes/blinds None 2 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ftZ 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 3 E 2 Vinyl Low-E Double Yes 0.33 0.31 N 7.5 ftZ 13 ft 0 in 0 ft 6 in None None 4 E 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ftZ 13 ft 0 in 2 ft 10 in None None 5 E 2 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ftZ 7 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 6 E 2 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ftZ 1 ft 4 in 2 ft 0 in Drapes/blinds Exterior 5 7 S 3 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ftZ 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 8 S 3 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft' 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 9 SW 4 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ftZ 7 ft 2 in 0 ft 4 in Drapes/blinds Exterior 5 10 W 5 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ftZ 9 ft 10 in 0 ft 10 in Drapes/blinds None 11 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ftZ 7 ft 2 in 0 ft 4 in Drapes/blinds Exterior 5 12 W 7 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ftZ 9 ft 10 in 0 ft 4 in Drapes/blinds Exterior 5 13 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ftZ 1 ft 4 in 1 ft 2 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 620 ftZ 620 ftZ 64 ft 8 ft 1 6/8/2021 4:56 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPI IT -RI IMMARV rNFrK1 icT RP'anRT - ------- ---- ---- INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 2590.3 142.11 266.8 .1312 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing[ HSPF:8.5 42 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 42 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ftz DUCTS / ---- Supply ---- # Location R-Value Area ---- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 503.2 ft Main 125.8 ft Proposed Qn Main --- cfm 151.4 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat: Y Coolin Jan Feb Mar Heating X Jan Feb Mar Ventin [ Jan Feb X Mar Ceiling Fans: Se APr May Jun 4 Jul f AuSep A r Ma rl JunX Jul X Au rl [X] A r [ Ma Jun [ Jul [ Aug Se [X] Oct Nov Oct Nov Oct HX Nov Dec Dec H Dec 6/8/2021 4:56 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 6/8/2021 4:56 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 8323 Amalfi Circle, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1748.70 ft2 b. Frame - Wood, Adjacent R=13.0 272.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 2523.00 ft2 6. Conditioned floor area (ft2) 2523 b. Knee Wall (Vented) R=19.0 80.00 ft2 7. Windows** Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 166.06 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Main, AH: Main 6 503.2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 35.56 ft2 a. Central Unit 42.0 SEER:15.00 SHGC: SHGC=0.70 d. U-Factor: other (see details) 20.83 ft2 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 6.223 ft. a. Electric Heat Pump 42.0 HSPF:8.50 Area Weighted Average SHGC: 0.288 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2EF:0.94 a. Electric Cap: 40 gallons SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2 Credits (Performance method) Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature-• I � � Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/8/2021 4:56 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1