Loading...
HomeMy WebLinkAboutDesign Pressure Report (Alter) - Master Craft Aluminum ProductsProperty Information Owner:Alter Address:8 Quito Ft Pierce, Fl 34951 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 37 62 7 31.5 -34.2 2 Int 26 38 7 32.5 -35.2 3 Int 74 62 7 30.0 -32.8 4 Int 106 85 7 28.6 -31.4 5 End 106 85 7 28.6 -35.7 6 End 108 85 7 28.6 -35.7 7 Int 53 55 7 31.0 -33.7 8 Int 53 55 7 31.0 -33.7 9 Int 25 38 7 32.5 -35.2 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1