Loading...
HomeMy WebLinkAboutAPPROVED Plan - page 1 of 2H G F E D C B A 8 7 6 5 4 3 2 1 H G F E D C B A 8 7 6 5 4 3 2 1 MAX. WIDTH: MIN. DEPTH: 28'6" SHAPE: FILL FROM EXCAVATION: TILE:FILTER: PUMP HP: LIGHTS: TRNFORM: MAIN DRAIN: SKIMMER: RETURNS: VALVED VAC LINE: DISCHARGE LINE: CHLORINATOR: HANDRAIL: DIVING BOARD: HEATER: VACUUM HEAD: VACUUM HOSE: LEAF SKIMMER: TREE / STUMP REMOVAL: REMOVE EXISITING CONCRETE: PUMP POOL PATIO: ELECTRICAL: POOL PATIO: EXISTING PATIO: DECK DRAIN: POOL CAPACITY: TURN-OVER RATE: TERMITE TREAT:BARRIER: MAX. LENGTH:45' 3'6"MAX. DEPTH:5'6" CUST HAUL ELEVATION:TBD INTERIOR FINISH:GEM CS200 POOL SPA POOL 5 COLOR LED SPA 1 CLR LED POOL SPA POOL 2 SPA 1 2 POOL 3 SPA 2 JETS:POOL NA SPA 8 INCL FILL LINE:INCL TO GROUND JANDY AP1400 SALT NA LADDER:NA NA SLIDE:NA JANDY 400K BTU PROPANE HTR INCL INCL INCL POLE: BRUSH: TEST KIT: INCL INCL INCL NA NA SCREEN ENCLOSURE: ED’S ELECTRIC TRAVERTINE BY TAURUS INCL 6-HRS. INCL FENCE NA MAX. WATER VELOCITY: MIN. SKIMMER FLOW: SURFACE AREA OF POOL: SPECIFICATIONS 2HP PHPM 300 WATT 100 W NA PUMP MAKE PER FBC 4501.20 1.5HP VS JEP FILTRATION PUMP COMPLIANT WITH ANSI/APSP/ICC-15 2011 GENERAL NOTES: 1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND WITH ALL LOCAL ORDINANCES AND ZONING REGULATIONS. 2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL WALLS AND FLOORS SHALL BE GUNITED OR POURED IN-PLACE CONCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS) COMPRESSIVE STRENGTH. 3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE DESIGN. 4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40. 5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F. APPROVAL. 6. BACK-WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES. 7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING SHALL CONTAIN WATER WITHIN PROPERTY LINES. PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR. 8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM. 9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE 10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A MINIMUM FREE AREA OF 3X THE AREA OF THE SUCTION LINE. 11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT CONNECTION TO CONFORM TO NATIONAL ELECTRICAL CODE- LATEST EDITION. 12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL, LIGHT FIXTURES & HOUSING, METAL PARTS OF LADDERS, HANDRAILS, DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER & GROUNDED TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER THAN #8 COPPER. 13. NO OVERHEAD OPEN WIRE OVER POOL WATER. 14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED 3 G.P.M. / S.F. OF FILTER AREA. NO BACK-WASH REQUIRED. 15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT SITE BEFORE STARTING THE PROJECT. CONTRACTOR SHALL VERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY. 16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO PREVENT UNDERMINING. 17. PLANTER SPECIES SHALL BE SELECTED WITH NON-INVASIVE ROOT SYSTEMS (SPECIES SELECTION BY OTHERS). AARON H. ALLEN PE, FL REG. NO. 86620 FL A. ALLEN ENGINEERING LLC, CA NO. 33042 2367 7TH STREET, LA VERNE, CA 91750 TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES 31,405 GALLONS SPA CAPACITY:1,100 GALLONS 6 FPS FROM TRUNK 25 GPM 933 SQ FT PERIMETER OF POOL: 145 LN. FT SEAL: BUILDER/JOB NAME: PERMIT NO.: DATE DRAWN: TBD 02/03/2021 DRAWN BY: CHECKED BY: APPROVED BY: MELIANS ADDRESS:3046 NW RADCLIFFE WAY JASON BARAN AARON H. ALLEN SCALE:¼” = 1' CITY:PALM CITY JOB INFORMATION NA SECTION THRU POOL 1 AScale: NTS WALL THICKNESS REQ.4 AScale: NTS TYP. WALL SECTION & WELL PT.5 AScale: NTS POOL DRAIN TYP.6 AScale: NTS EQUIPOTENTIAL BOND GRID 7 AScale: NTS WATER BONDING 8 AScale: NTS ELECTRICAL SCHEMATIC 7 CScale: NTS HANDRAIL BONDING 7 BScale: NTS W.L. #8 SOLID COPPER BOND WIRE W/ APPR. CLAMPS (SEE NOTE 3) 8 GAUGE SOLID COPPER WIRE SOIL 18" MIN. (ENTIRE PERIMETER) NOTES: 1. MINIMUM 18" FROM ENTIRE EDGE OF POOL PERIMETER BURIED 4" TO 6" DEEP 2. INSTALL PER N.E.C. 2017 SEC. 680.26 (WHERE ADOPTED) 3. #8 SOLID COPPER BOND WIRE WITH APPROVED CLAMPS ON EACH SIDE OF POOL (4 TOTAL) DECK PER DETAIL A/5 ANSI-7/ANSI-15 8 EScale: NTS POOL DRAIN CERTIFICATION 7 EScale: NTS EQUIPMENT LAYOUT 7 GScale: NTS UNDERWATER LIGHT 8 BScale: NTS PUMP CURVES 7 HScale: NTS SHORING REQUIREMENTS 3 AScale: NTS SOIL EQUIPMENT PAD PB-2008 BONDING WIRE TO GRID VARIESNOTE: 1. PB-2008 TO BE INSTALLED NEAR OR UNDER EQUIPMENT PAD FROM POWER SUPPLY POOL FINISH APPROVED GROUND CLAMP CONTINUOUS BOND WIRE COMMON TO POOL STEEL, RAILS & EQUIPMENT 1" LIGHT CONDUIT WATER LEVEL NICHELESS UNDERWATER LIGHT 18" MIN.CIRCULAR MAIN DRAINS MIN. 3' SEPARATION REQ. 3" SUCTION LINE MAX 181 G.P.M. TO FILTRATION PUMP NOTES: 1. APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 (SEE CERT. OF COMPLIANCE) - COVERS MUST BE REPLACED EVERY 5 YEARS 2. APPROVED WITH THE 2020 FLORIDA BUILDING CODE FOR RESIDENTIAL 7TH EDITION AND THE ANSI/APSP-7 2013 FOR SUCTION ENTRAPMENT AVOIDANCE 4" PLUMBING LINES FROM SUMP W/ 3" TEE 3 FT. MIN. 6 FPS MAX EXIST. FTGN. SOIL 3 ft. 6 ft. 9 ft.5 ft.4" WALL #3 REBAR @ 12" O.C.E.W.ANGLE OF REPOSENOTES: EXCAVATION INTO ANGLE OF REPOSE ALLOWED IF: 1. SHORING IS SUFFICIENT TO SECURE SOILS FROM EROSION/SETTLEMENT 2. NO UNDERMINING OCCURS UNLESS APPROVED BY ENGINEER 3. COMPACTION TEST PROVIDED AT C.O. 6" WALL #3 REBAR @ 12" O.C.E.W. 8" WALL #3 REBAR @ 12" O.C.E.W. 2"X4" @ 24" O.C. ½" PLYWOOD NOTE: 1. SHORING TO BE INSTALLED WHEN POOL SHELL IS CLOSER THAN 5 FT TO HOME, OR EXCEEDS THE ONE TO ONE RATIO OF THE ANGLE OF REPOSE EXIST. FTGN. SOIL < 5' OR 1:1 MAIN DRAIN SKIMMER COLOR LED VACUUM LINE SYMBOL LEGEND DECO DRAIN EXISTING FACILITY CHANNEL DRAIN ELEVATION MARKER B BUBBLER JANDY UPLIGHTUL DOOR/WINDOW ALARM BABY BARRIER XX.X’ DECK PER DETAIL A/5 x0 ft.2 ft. 4.8 in.4 ft.8 ft. REVISION DATE:NA · APPROVED WITH THE 2020 FLORIDA BUILDING CODE FOR RESIDENTIAL 7TH EDITION AND THE ANSI/APSP-7 2013 FOR SUCTION ENTRAPMENT AVOIDANCE TO 8FPS SUCTION LINES,10FPS MAX RETURN SWIMOUT CUT SECTION 8 HScale: NTS 20" MAX. 18" 8880 GLADES CUT OFF ROAD PORT ST. LUCIE, FL 34986 CUSTOMER APPROVAL: REVISION NOTE: 1. WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE 8 FPS MAX DOCUMENT PROPERTY OF A. ALLEN ENGINEERING INC. & A&G CONCRETE POOLS INC., DUPLICATION AND/OR DISTRIBUTION IN PART OR WHOLE WITHOUT WRITTEN CONSENT FROM THE OWNER(S) WILL BE PUNISHABLE UNDER AWCPA COPYRIGHTS LAWS. NOTE: 1. WHERE APPLICABLE PER NATIONAL ELECTRICAL CODE #8 GROUND WIRE DECK PER DETAIL A/5 8 1 P1 WF 65 P2 9 10 HG B V KEY: 1. 2.5" POOL RETURN TO FIRST TEE, 1.5" TO POOL 2. 2" SUPPLY LINE TO BUBBLER LOOP AROUND SPA 3. 2" SUPPLY LINE TO BUBBLER LOOP ON SUNSHELF 4. 2.5" RETURN TO SPA 5. 2" SKIMMER LINE 6. 1.5" VACUUM LINE 7. 3" POOL MAIN DRAIN 8. 3" SPA MAIN DRAIN SUCTION 9. 3" JET SUCTION 10. 2.5" RETURN TO HYDRO JETS P1. 1.5HP JANDY VARIABLE JEP PUMP WITH W/APPR HAIR AND LINT STRAINER P2. 2HP JANDY JET PHPM PUMP WITH W/APPR HAIR AND LINT STRAINER HG. JANDY 400K BTU NAT. GAS HEATER F. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE (MUST HOLD 35 PSI FOR 30 MINUTES MINIMUM) W. 1.5" TO WASTE OR TO GROUND V. VALVES (TYP) B. PB-2008 WATER BONDING TO GRID (SEE DETAIL A/8) S. JANDY AP1400 SALT SYSTEM 4 THERAPY PUMP = 2HP JANDY STEALTH PLUS PHPM LOW SPEED = 36 GPM MAX. HIGH SPEED = 142 GPM @ 45 TDH MAX. 3" SUCTION PIPE @ 142 GPM = 7.29 FT./SEC. (8FT./SEC. MAX. – SUCTION LINES) 2.5" PRESSURE PIPE @ 142 GPM = 9.8 FT./SEC. (10 FT./SEC. MAX. – PRESSURE LINES) 3" PLUMBING LINES FROM SUMP W/ 3" TEE UNBLOCKABLE CHANNEL DRAIN NOTES: 1. APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 (SEE CERT. OF COMPLIANCE) 2. APPROVED WITH THE 2020 FLORIDA BUILDING CODE FOR RESIDENTIAL 7TH EDITION AND THE ANSI/APSP-7 2013 FOR SUCTION ENTRAPMENT AVOIDANCE 3" SUCTION LINE TO PUMP MAX: 181 GPM / 8 FPS TO FILTRATION PUMP 3" SUCTION LINE TO PUMP MAX: 181 GPM / 8 FPS TO JET PUMP SPA DRAIN TYP. Scale: N.T.S. SPA WALL SECTION Scale: N.T.S. 5 B 4 B JET PUMP CURVE Scale: N.T.S. 6 H 7 S 6"X6" TILE INTERIOR FINISH TRAVERTINE DECK #4 @ 12" O.C.B.W. TO PUMP THREADED PLUG SECURED GRATE TOOLS REQUIRED FOR REMOVAL GRAVEL BED NOTES: 1. REMOVE GRATE & WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP LINE WHEN EMPTYING POOL 2. FOR DEPTHS GREATER THAN 6' ADD 1- #3 COVE BAR @ 6" O.C. 3. SLOPE DECK ¼” PER FOOT 1 ¼” 4" ROCK BASE BY TAURUS CONSTRUCTION TRAVERTINE COPING 2 SPA DRAIN CERTIFICATION Scale: N.T.S. 2 B S.P.S.T. TOGGLE SWITCH (3)- #6 &(1) #10 GROUND THHN CU IN 1" RPVC CONDUIT MANUAL MOTOR SWITCH VARIABLE SPEED PUMP MOTOR W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITH-IN ½” CONDUIT TIME CLOCK W.P. DISCONNECT HEATER (GAS)-IGNITION SWITCH 3-#12 THHN CU WITHIN ½” CONDUIT (CONNECT TO 20 AMP-1 POLE GFCI BREAKER) JUNCTION BOX 12 VOLT TRANSFORMERS NOTES: 1. ALL ELECTRICAL TO COMPLY WITH 2017 NATIONAL ELECTRIC CODE. 2. 3-#12 THHN CU WITHIN ½” MIN. CONDUIT FOR POOL LIGHT (S) 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER. 4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B) 5. INSTALL 125V 15 AMP WEATHERPROOF DUPLEX GFCI RECEPTACLE AT LEAST 10' AWAY AND NOT MORE THAN 20' FROM THE INSIDE WALL OF THE POOL 6. POOL PANEL AND SWITCHES MUST BE AT LEAST 5' FROM THE INSIDE WALL OF THE POOL 7. PROVIDE PROPER WORKING CLEARANCE SPACES FOR ELECTRICAL EQUIPMENT AS PER HO-26 OF NFPA 70 W.P. DISCONNECT SALT SYSTEM W/BUILT IN OVERLOAD SWITCH W/3-#10 THHN CU WITH-IN ½” CONDUIT JANDY THERAPY PLUS HP PUMP MOTOR W/ BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITHIN ½” MIN. CONDUIT POOL LIGHTS SEE SPECS FOR QUANT. (GFI NOT REQUIRED) SPA LIGHT SEE SPECS FOR QUANT. (GFI NOT REQUIRED) 60 AMP POOL PANEL W/(3) - #6 THHN CU WITHIN 1” ELECTRICAL CONDUIT W/ INTEGRAL TIME CLOCK FOR PUMPS, MOTOR, AND HEATER · ELECTRIC HOOKUP BY ED’S ELECTRIC · TRAVERTINE DECKING WITH 4" ROCK BASE BY TAURUS CONSTRUCTION · TRAVERTINE COPING INSTALLED BY A&G POOLS · GAS HOOKUP BY HOMEOWNER · PERIMETER YARD FENCE BY HOMEOWNER · CUTTING AND CAPPING OF IRRIGATION BY A&G · IRRIGATION REROUTING BY HOMEOWNER DIRECTIONS: I95 SOUTH TO BECKER ROAD EXIT, TURN LEFT, AT THE END OF BECKER ROAD, TURN LEFT, TURN RIGHT INTO RIVER BEND FILTRATION PUMP = 1.5HP JANDY VARIABLE JEP VARIABLE SPEED LOW SPEED – 36 GPM MAX HIGH SPEED = 147 GPM @ 38 TDH 3" BRANCH PIPE @ 72 GPM = 4.13 FT./SEC. (6 FT./SEC. MAX. – PRESSURE LINES) 3" SUCTION PIPE @ 147 GPM = 7.68 FT/SEC. (8 FT./SEC. MAX. – SUCTION LINES) 2.5" PRESSURE PIPE @ 147 GPM = 9.74 FT./SEC. (10 FT./SEC. MAX. – PRESSURE LINES) 200 SQ. FT. CARTRIDGE FILTER X 0.375 = 75 GPM BACKWASH VALVE NO TILE DECK PER DETAIL A/5 #3 @ 12" O.C.B.W. STEEL-TEX FORM OR KRAFT WALL6" 4-½” STEP NOTES: 1. CHANNEL DRAIN GRATE SHALL BE SECURED IN PLACE SO THAT TOOLS ARE REQ. FOR REMOVAL 2. STEP 9" BELOW WATER LINE, MIN. 240 SQ. INCHES 3. SPA ELEVATIONS PER PLAN VIEW INTERIOR FINISH SPA BENCH 18" BELOW W.L.8" 8" OF WET DECK WITH 4" OF WATER REFER TO PLAN FOR ELEVATIONS CHANNEL DRAIN 3 STEP NOTES: 1. TREAD IS MIN. OF 10" WIDE. 2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 4000 PSI. 4. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY NOTES: 1. (5.6.1) THE SLOPE OF THE FLOOR FROM THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1 FOOT IN 7 FEET TO THE POINT OF THE FIRST SLOPE CHANGE 2. (5.6.2) CHANGES IN SLOPE BETWEEN SHALLOW AND DEEP AREAS SHALL BE AT A MINIMUM WATER DEPTH OF 2 FEET 9 INCHES AND BE AT LEAST 6 FEET FROM THE SHALLOW END 3. (5.6.3) THE SLOPE OF THE FLOOR FROM THE POINT OF THE FIRST SLOPE CHANGE TOWARD THE DEEP END SHALL NOT EXCEED 1 FOOT IN 3 FEET 4. WALLS SHALL NOT SLOPE > 11 DEGREES 5. HAND HOLD TO BE INSTALLED WHERE DECK RAISED +6" ABOVE POOL 45' 0 FLOOR SLOPES #4 STEEL @ 12" O/C E.W. WATERLINE TILE MAIN DRAIN 10'5" 6" 5'6"3'6" 4-½” 10" MIN. TREAD 12"3' 3'6" STEPS BEYOND 12"12"SUNSHELF AND SPA 11'20'7" HOMEOWNER IS KAZ MELIANS CELL IS: 772-979-3865 PAGE 1 OF 2