Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the .Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,g34r5;C Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,94AS,7 Concrete or Clay Tile A, B, D; E 1.E234k5i6s. Metal Roofs A, B, D 1,24.5&T Wood Shingles and Shakes A, B, D i.,2;45,6i7 Other As Applicable 1,2,34Agj7— ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 i ST: LUCK WORKS Section A (General Information) Master Permit No. Process No. Contractors Name: �arT��sEt_wu��rnC-��(cr LLC. License# IO2Sj Job Address 7� 1" ,7l-COWS R-'V llG I?LoxxG6 ROOF CATEGORY El Low Slope E3 Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles Asphaltic Shingles .0 Metal Panel/Shingles Mood Shingles/Shakes 10 Prescriptive BUR-RAS 150 ROOF ROOF TYPE. 13 New roof E) Repair 17 Maintenance Peroofing El Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) 2 b©c2 Total (SF) 1000 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. r` ST. LUCIE WORKS i i Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base.Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_.." oc @ Lap, # Rows "00 " Zone 1:`" oc @ Lap,# Rows. ca " Zone 2:_" oc @ Lap, # Rows . `. Zone 3:`" oc @ Lap, # Rows .00, Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. ST. LUCIE.WORKS on D (Steep Slope Roof System) Roof System Manufacturer: OLUC—t l 5 Notice of Acceptance Number: vlinimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1-� 110Zone 2e' S'Z Zone 2n.-_71_,rZone 2r:_(97q,3 Zone 3e _gg, Zone 3r: QeekType TypwUndw*ftfit Roof Slope 12 lrisuFat'rorr Fire BarrweF tj RW-W V .81081(dril. fastener Type Spacing:ESL r Adhesive Type': Type. Cap; Sheet lean Rdd-Helght: rl Roo€ covering; Type &_Size Drip 2 Iz " - =A ST. LUCIE WORKS Section E (Tile Calculations) For Moment based the systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mr. If the Mf values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1 'Moment Based Tile Calculations Per RAS 12T (Zone 1: -. �. Product Approval M, (Zone 2e: _ X ==- =J( Product Approval Mf (Zone 2n: xx, Product Approval Mr (Zone 2r: Product Approval Mf (Zone 3e: % _ ..._..^ l Product Approval Mf (Zone 3r: X`X. -' -J. = Product Approval Mf Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.S 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based tile systems • For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:= ) -W: cos r =Frl Product Approval F' (Zone 2e: x L =x W:=) -W: cos r =Fr2e Product Approval F' (Zone 2n: x L =x W:= ) -W: cos r =Fr2n Product Approval F' (Zone 2r:. x L =x W:=_-W: cos r =Fr2r Product Approval F' (Zone 3e: x L =x W:=) -W: cos r =Fr3e Product Approval F' (Zone 3r: x L =x W:=) -W: cos r =Fr3r Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application.