HomeMy WebLinkAboutELECTRICAL RISER09/15/2021 E-1 1 OF 2DATEREVISIONMARKDATE: SHEET DATEDESIGNEDDRAWNCOMPLETE ELECTRIC, INC.637 SEBASTIAN RD.SEBASTIAN, FL. 32958(772) 388-0533EC 0001911CONDUIT AND WIRE SCHEDULE SYMBOL DESCRIPTION EXISTING OVERHEAD SERVICE RISER, WEATHERHEAD, AND UTILITY FEEDERS EXISTING 1/2"PVC W/ (1) #8 BARE CU 1-1/2"PVC W/ (4) #3 THHN CU 1-1/2"PVC W/ (4) #3 THHN CU, (1) #8 THHN CU GROUND, (5) #14THHN CU EXISTING 2"AL C. W/ SEAL OFF FITTINGS 1-1/4"PVC W/ (4) #3 THHN CU, (1) #6 THHN CU GROUND 1/2"PVC W/ (1) #8 BARE CU 3/4"PVC W/ (6) #14 THHN CU (START/STOP SIGNAL) 3/4"PVC W/ (5) #12 THHN CU (BATTERY CHARGER/BLOCK HEATER) A B C D ELECTRICAL LEGEND: SURFACE MOUNT 120/204V, 1Ø, 3-WIRE PANELBOARD FLUSH MOUNT 120/204V, 1Ø, 3-WIRE PANELBOARD SURFACE MOUNT 277/480V, 3Ø, 4-WIRE PANELBOARD FLUSH MOUNT 277/480V, 3Ø, 4-WIRE PANELBOARD UTILITY METER CAN OR METER/MAIN COMBO UNIT SURFACE MOUNT AUTOMATIC TRANSFER SWITCH NON-FUSED DISCONNECT FUSED DISCONNECT 30AR NF 3R FRAME SIZE NEMA RATING NON FUSED 30AR 30AF 3R FRAME SIZE NEMA RATING FUSE SIZE POINT OF NEW CONNECTION AC ALTERNATING CURRENT A/C AIR CONDITIONING AFG ABOVE FINISHED GRADE AL ALUMINUM AHU AIR HANDLING UNIT ATS AUTOMATIC TRANSFER SWITCH AMP AMPERE AFCI ARC FAULT CIRCUIT INTERRUPTER ANSI AMERICAN NATIONAL STANDARDS INSTITUTE C CONDUIT CU COPPER CONDUCTOR COVB CITY OF VERO BEACH DC DIRECT CURRENT DISC DISCONNECT EXIST EXISTING FPL FLORIDA POWER & LIGHT G GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER IRC INDIAN RIVER COUNTY KVA KILOVOLTAMPERE KW KILOWATT MC METAL CLAD CABLE MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANELBOARD MTS MANUAL TRANSFER SWITCH MLO MAIN LUGS ONLY NEC NATIONAL ELECTRICAL CODE NTS NOT TO SCALE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFPA NATIONAL FIRE PROTECTION ASSOCIATION NON-SE NON SERVICE ENTRANCE RATED PLCS PLACES (QUANTITY) PNL PANEL PVC POLYVINYL CHLORIDE CONDUIT RMC RIGID METAL CONDUIT RTU ROOF TOP UNIT SE SERVICE ENTRANCE RATED TYP TYPICAL TEMP TEMPORARY TRANS, TX TRANSFORMER UG UNDERGROUND UL UNDERWRITERS LABORATORY UON UNLESS OTHERWISE NOTED V VOLT VA VOLT AMPERE W WATT XFMR TRANSFORMER ABBREVIATIONS:(SOME SYMBOLS SHOWN MAY NOT PERTAIN TO THIS PROJECT) NO SCALE 1 LIFT STATION ELECTRICAL RISER GENERAL NOTES: 1.LIGHT LINE WORK REPRESENTS EXISTING TO REMAIN. 2.DARK AND RED LINE WORK REPRESENT NEW EQUIPMENT, CONDUIT, AND WIRE. EXISTING (2) 5/8"x8'LONG COPPER GROUND RODS W/ #2 CU BC HORIZONTAL STAINLESS STEEL UNISTRUT (TYPICAL 4 PLACES) 3"DIAx10'-0"LONG AL. CONDUIT POST WITH AL. CONDUIT CAP GRADE E E TO LIFT STATION EXISTING LIFT STATION CONTROL CABINET WITH 100AMP MAIN BREAKER. GRADE 100AMP BREAKER NEW DIESEL GENERATOR: GENERAC 20KW 120/240V, 3Ø 28-01 (TYP. 4 PLACES)LIFT STATION RISERAND NOTESNEW GENERATOR FOR:OCEAN RESORTS5101 N. HIGHWAY A1AFORT PIERCE, FL. 34949SCOPE OF WORK: ·PROVIDE AND INSTALL NEW SUPPORT RACK FOR NEW ATS AND EXISTING CONTROL CABINET. ·PROVIDE AND INSTALL 100 AMP SE RATED ATS ON NEW RACK. ·INSTALL NEW ATS UNDERGROUND FEEDER FROM EXISTING METER CAN. ·PROVIDE AND INSTALL CONDUIT AND CONDUCTORS FOR FROM ATS TO GENERATOR. ·PROVIDE AND INSTALL (1) 20kW 120/240V, 3Ø GENERAC DIESEL GENERATOR WITH 95 GALLON DIESEL BASE FUEL TANK. ·PROVIDE AND INSTALL CONDUIT AND CONDUCTOR FROM NEW GENERATOR TO NEW ATS. EXISTING 100 AMP METER CAN 120/240V 3Ø RISER DIAGRAM GENERAL NOTES: 1.SERVICE HAS BEEN SIZED FOR 2%VD AND BRANCH CIRCUITS HAVE BEEN SIZED FOR A MAXIMUM OF 3%VD. VOLTAGE DROP FOR FEEDERS AND BRANCH CIRCUITS COMBINED ARE SIZED FOR A MAXIMUM OF 5% PER FBC-EC-C405.6.3. 2.ALL NEW ABOVE GROUND CONDUIT TO BE ALUMINUM. TRANSITION TO PVC WHENEVER CONDUIT IS TO GO UNDERGROUND. VD: VOLTAGE DROP CONSTRUCTION NOTES: 28-01 PROVIDE STAINLESS STEEL STRUT STRAP AT THIS LOCATION. 28-XX NEW 100 AMP 120/240V,3Ø GENERAC SE RATED ATS EXISTINGA F I E F (2) 5/8"x8'LONG COPPER GROUND RODS W/ #8 CU G G H I H D F:\GENERATOR DRAWINGS\08-27-2021 Ocean Resorts Lift Station\08-27-2021 Ocean Resorts Lift Station.dwg, 9/15/2021 1:52:48 PM EXISTING POLE MOUNTED TRANSFORMERS EXISTING OVERHEAD UTILITY DROP NEW RACK WITH ATS AND EXISTING CONTROL CABINET EXISTING UTILITY POLE WITH METER CAN EXISTING VAULT EXISTING WET WELL EXISTING CHAIN LINK FENCE EXISTING CONCRETE PAD 3'-0" NEW GENERATOR AND PAD 09/15/2021 2 OF 2GENERATOR SITEPLAN, DETAILS &NOTESDATEDESIGNEDDRAWNCOMPLETE ELECTRIC, INC.637 SEBASTIAN RD.SEBASTIAN, FL. 32958(772) 388-0533EC 0001911DATEREVISIONMARKDATE: SHEET E-2 1" = 10'-0" 2 ENLARGED GENERATOR PLAN N W S E GENERATOR ANCHORING NEW GENERATOR FOR:HARMONY RESERVE LIFT STATION5911 RED MAPLEVERO BEACH, FL. 32966ELECTRICAL GENERAL NOTES: 1.THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION DETAIL WITH THE LOCAL UTILITY POWER COMPANY. 2.THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION (2017), LOCAL ORDINANCE, AND THE NATIONAL ELECTRIC CODE THIRTEENTH EDITION NFPA 70 (2014). 3.ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMAN LIKE MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN LICENSED IN THE STATE OF FLORIDA. 4.THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND FASTENED, WITH WORKING SPACE PER NEC 110.26. 5.PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SUBJECT TO DAMAGE. PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. 6.ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. 7.DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW EXACT LOCATIONS OF DEVICES AND EQUIPMENT. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS. 8.GROUNDING PER NEC ARTICLE 250. 9.INSTALL LOAD CENTERS AND DISCONNECTS SO THAT AT LEAST 3 1/2FEET OF WORKING SPACE CAN BE MAINTAINED PER NEC 110.26. 10.ALL MATERIALS SHALL BE NEW AND SHALL BEAR U.L. LABELS WHERE APPLICABLE. 11.ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROCESS OF CONSTRUCTION. 12.PROVIDE FAULT CURRENT MARKER PER NEC 110.24 AND ARC-FLASH DECALS PER NEC 110.16. 13.EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED. ALL COMPONENTS OF THE ELECTRICAL SYSTEM LOCATED OUTDOORS OR INDOORS WHERE EXPOSED TO SIGNIFICANT MOISTURE SHALL BE WEATHERPROOF, NEMA 3R, AS A MINIMUM INDICATED ON THE CONTRACT DRAWINGS OR NOT. 14.PROVIDE TYPED PANEL DIRECTORIES FOR ALL NEW PANELBOARDS, AND EXISTING PANELBOARDS AFFECTED BY THIS PROJECT. DIRECTORIES SHALL REFLECT PROJECT AS-BUILT CONDITIONS FOR ALL BRANCH CIRCUITS. DIRECTORIES SHALL INCLUDE WHERE EACH PANEL IS FED FROM. ADDITIONALLY, EACH BRANCH CIRCUIT LOAD DESCRIPTION SHALL INCLUDE THE ROOM NUMBER(S) FOR EACH LOAD SERVICE. ROOM NUMBERS SHALL BE BASED ON ACTUAL ROOM SIGNAGE INSTALLED IN FIELD. COORDINATE EXACT ROOM NUMBERS WITH A/E AND OWNER PRIOR TO COMPLETION OF PANEL DIRECTORIES. 15.PROVIDE ENGRAVED PLASTIC LAMINATE NAME TAGS ON EACH SWITCHBOARD, SWITCHGEAR, DISTRIBUTION PANEL, PANELBOARD, MOTOR CONTROL CENTER, SAFETY SWITCH, ENCLOSED CIRCUIT BREAKER, CABINET, STEP-DOWN TRANSFORMER, TRANSFER SWITCH , ETC., AND ANY OTHER MAJOR COMPONENT OF THE ELECTRICAL SYSTEM. 16.PROVIDE ENGRAVED PLASTIC LAMINATE NAME TAGS FOR EACH DISTRIBUTION BREAKER OR BRANCH CIRCUIT BREAKER IN SWITCHGEAR, SWITCHBOARDS, MOTOR CONTROL CENTERS AND OTHER DISTRIBUTION EQUIPMENT. NAME TAG SHALL INCLUDE LOAD DESCRIPTION AND ROOM NUMBER FOR EACH LOAD SERVICE. 17.PROVIDE LABELS ON THE INSIDE OF EACH DEVICE COVER PLATE, IDENTIFYING THE PANES(S)/CIRCUIT NUMBERS(S). 18.PROVIDE NEATLY, HANDWRITTEN IDENTIFICATION ON THE EXTERIOR COVER OF ALL JUNCTION AND PULL BOXES, WIREWAYS. IDENTIFYING THE PANEL(S)/CIRCUIT NUMBERS(S) CONTAINED WITHIN. TOP VIEW LEFT ELEVATION FRONT ELEVATION DRILL DRILL 1/4" DEEPER THAN ANCHOR EMBEDMENT CLEAN DRIVE TIGHTEN 3-5 X DRILL BIT SIZE: 1/2"TIGHTENING TORQUE: 45ft.lbs. MIN. ANCHOR EMBEDMENT: 2-1/2" 1/4" MIN.88" 38" 8" MIN. 38"88" NOTE: 1.THE USE OF A CARBIDE DRILL BIT CONFORMING TO ANSI STANDARD B212.15 IS RECOMMENDED. 2.ANCHOR BOLTS TO BE 3/8"DIA.x3-3/4"LONG UNLESS OTHERWISE NOTED. 1/2" = 1'-0" 3 GENERATOR PAD DETAIL N.T.S. 1 OVERALL SITE PLAN N W S E 1 2 F:\GENERATOR DRAWINGS\08-27-2021 Ocean Resorts Lift Station\08-27-2021 Ocean Resorts Lift Station.dwg, 9/15/2021 1:52:21 PM