Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MANJ
Air Calcs LLC Load Short Form Job: 1433 Date: 3/4/2021 Entire House By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyrrie@aircalcs.com Project Information For: Clark Residence,Groza Builders,Inc 5705 Emerson Ave.,Ft.Pierce,FL 34951 Design Information Htg Clg Infiltration Outside db(°F) 41 90 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD(°F) 29 15 Fireplaces 0 Daily range - L Inside humidity(%) 30 50 Moisture difference(gr/Ib) 2 57 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1S036-230C** AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.0 kW Sensible cooling 24220 Btuh Heating output 23827 Btuh Latent cooling 10380 Btuh Temperature rise 19 °F Total cooling 34600 Btuh Actual airflow 1153 cfm Actual airflow 1153 cfm Air flow factor 0.052 cfm/Btuh Air flow factor 0.052 cfim/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 0.76 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Dining Room 179 3360 2134 173 111 Bed 4 189 3394 2401 175 125 Wtr Clst 26 43 63 2 3 Master Bath 107 1431 670 74 35 WIC 41 56 82 3 4 Lin2 8 0 0 0 0 Master Bed 266 3823 3118 197 163 Bed 3 147 2449 1302 126 68 Laundry 52 609 924 31 48 Lin3 6 0 0 0 0 Lin 5 0 0 0 0 Bed 2 175 2935 2106 151 110 Bath 2 64 625 284 32 15 Hall 2 33 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. W rightsoft, 2021-Mar-19 11:28:59 A II,-=Iae,-"e--.,I—— Right-Sute®Universal 202121.0.03RSU27054 Page 1 ACCP Limerrts\WrightsoftHVAC\5705 Emerson Ave GBl.rup Calc=MJ8 Front Door faces:SW Family Room 315 2633 5420 136 283 Hall 26 0 0 0 0 Kitchen 238 1004 3618 52 189 Li n4 5 0 0 0 0 Entire House 1882 22363 22122 1153 1153 Other equip loads 1795 953 Equip.@ 0.95 RSM 22013 Latent cooling 7345 TOTALS 1882 24158 29358 1153 1153 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. W rlghtsoft, 2021-Mar-19 11:28:59 A II,-=Iae,-"e--.,I—— Right-Sute®Urrversal202121.0.03RSU27054 Page 2 ACCP. ...rmerrts\WrightsoftHVAC\5705 Emerson Ave GBI.rup Calc=MJ8 Front Door faces:SW Buildin Anal sis Job: 1433 Air Calcs, LLC g Y Date: 3/4/2021 Entire House By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com Project • • For: Clark Residence,Groza Builders,Inc 5705 Emerson Ave.,Ft.Pierce,FL 34951 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl,FL,US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD(°F) 29 15 Latitude: 28°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 2.4 56.9 Dry bulb(°F) 41 90 Infiltration: Daily range(°F) - 15 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 amme Component Btuh/ft2 Btuh %of load Walls 2.6 3836 15.9 Walls ventilation Glazing 9.3 1468 6.1 Doors 3.7 74 0.3 Ceilings 1.0 1858 7.7 Glazin Ducts Floors 3.0 5679 23.5 Other Infiltration 2.5 3241 13.4 Ceilings Ducts 6207 25.7 Piping 0 0 Humidification 0 0 Ventilation 1795 7.4 Adjustments 0 Floors nfiltration Total 24158 100.0 • • • Component Btuh/ft2 Btuh %of load Walls 1.6 2384 10.3 Walls Ventilation Glazing 22.7 3571 15.5 Doors 3.7 75 0.3 Internal Gains Ceilings 1.5 2742 11.9 Glazing Floors 0 0 0 Infiltration 0.7 906 3.9 Other Ducts 6943 30.1 Ventilation 953 4.1 Internal gains 5500 23.8 Ceilings Blower 0 0 Adjustments 0 Infiltration Ducts Total 23075 100.0 Latent Cooling Load=7345 Btuh Overall U-value=0.082 Btuh/112--°F Data entries checked. wrightsoft- 2021-Mar-19 11:28:59 ^., k-I-rII °^a,I I..,.I. °r I I Right-Suite®Universal 2021 21.0.03 RSU27054 Page 1 unents\WrightsoftHVAC\5705 Emerson Ave GBl.rup Calc=MJ8 Front Door faces:SW Component Constructions Job: 1433 Air Calcs, LLC Date: 3/4/2021 Entire House By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com Project • • For: Clark Residence,Groza Builders,Inc 5705 Emerson Ave.,Ft.Pierce,FL 34951 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl,FL,US Indoor temperature(T) 70 75 Elevation: 26 ft Design TD(T) 29 15 Latitude: 28°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grAb) 2.4 56.9 Dry bulb(T) 41 90 Infiltration: Daily range(T) - 15 ( L ) Method Simplified Wet bulb(T) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ftUF W-T/Btuh Btuh/ft' Btuh Btuh/ft' Btuh Walls Block R-9 Wall:Blk wall,Stuc Ext,8"thk,R-9 Foam Fill, 1/2"Gyp Bd n 208 0.089 9.0 2.58 536 1.65 343 e 185 0.089 9.0 2.58 476 1.65 305 s 372 0.089 9.0 2.58 959 1.65 613 w 350 0.089 9.0 2.58 902 1.65 577 all 1115 0.089 9.0 2.58 2873 1.65 1838 Block R-9 Wall:Knee wall,R-30 KW Ins, 1/2"Gyp Bd Fnsh e 11 0.042 30.0 1.21 13 1.78 20 s 6 0.042 30.0 1.21 7 1.78 11 all 17 0.042 30.0 1.21 21 1.78 30 Partitions Block R-9 Wall:Knee wall,R-30 KW Ins, 1/2"Gyp Bd Fnsh 41 0.042 30.0 1.21 49 1.78 73 Fnn Wall, 1/2"Gyp Bd Ext,R-11 Cav Ins, 1/2"Gyp Bd Int Fnsh,2"A", 16" 304 0.101 11.0 2.94 893 1.46 443 OC Stud Windows Impact: Impact;NFRC rated(SHGC=0.22);50%blinds 45°,medium; n 16 0.320 0 9.28 148 7.59 121 50%outdoor insect screen;foreground=green grass(0.23); 1 ft overhang (5.3 ft window ht, 1 ft sep.);6.8 ft head ht Impact: Impact;NFRC rated(SHGC=0.21);50%blinds 45°,medium; e 3 0.280 0 8.12 21 11.5 30 50%outdoor insect screen;foreground=green grass(0.23);3.7 ft overhang(2.6 ft window ht, 1 ft sep.);6.8 ft head ht Impact: Impact;NFRC rated(SHGC=0.22);50%blinds 45°,medium; e 46 0.320 0 9.28 430 23.0 1068 50%outdoor insect screen;foreground=green grass(0.23); 1 ft overhang w 23 0.320 0 9.28 215 23.0 534 (5.25 ft window ht, 1 ft sep.);6.8 ft head ht all 70 0.320 0 9.28 646 23.0 1601 Impact: Impact;NFRC rated(SHGC=0.22);50%blinds 45°,medium; s 13 0.320 0 9.28 118 9.59 122 50%outdoor insect screen;foreground=green grass(0.23); 1 ft overhang (4.25 ft window ht, 1 ft sep.);6.8 ft head ht Impact: Impact;NFRC rated(SHGC=0.22);50%blinds 45°,medium; w 16 0.320 0 9.28 150 23.0 373 50%outdoor insect screen;foreground=green grass(0.23); 1 ft overhang (5.4 ft window ht, 1 ft sep.);6.8 ft head ht Impact: Impact;NFRC rated(SHGC=0.26);50%blinds 45°,medium; w 40 0.330 0 9.57 385 26.2 1052 50%outdoor insect screen;foreground=green grass(0.23); 1 ft overhang (6.7 ft window ht, 1 ft sep.);6.8 ft head ht -Pk wrightsoft- 2021-Mar-1 9 11:28:59 --k=de-•,.e a«a-a.-'P ' Right-Sute®Universal 202121.0.03 RSU27054 Page l ACCA unerts\WrightsoftHVAC\5705 Emerson Ave GBl.rup Calc=MJ8 Front Door faces:SW Doors Fbrgls Door a 20 0.127 7.0 3.69 74 3.73 75 Ceilings Attic,Shngl Roof,R-30 Ceil Ins,5/8"Gyp Bd 1882 0.034 30.0 0.99 1858 1.46 2742 Floors On Grade Depth,Tile Flr Fnsh 198 0.989 0 28.7 5679 0 0 Q: 41- Wrlghtsoft® 2021-Mar-1911:28:59 11 Right-SLite@Uriversal 202l 2l.O.O3 RSU27054 Page 2 '01 unents\WrightsoftHVACW705 Emerson Ave GBl.np Calc=MJ8 Front Door faces:SW Air Caics, LLC Project Summary Date: 1433 432021 Entire House By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com Project • • For: Clark Residence,Groza Builders,Inc 5705 Emerson Ave.,Ft.Pierce,FL 34951 Notes: Design Information Weather: St Lucie Co Intl,FL,US Winter Design Conditions Summer Design Conditions Outside db 41 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 29 °F Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 57 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 16156 Btuh Structure 15178 Btuh Ducts 6207 Btuh Ducts 6943 Btuh Central vent(56 cfm) 1795 Btuh Central vent(56 cfm) 953 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24158 Btuh Use manufacturer's data n Rate/swin multiplier 0.95 Infiltration Equipmen�sensible load 22013 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3069 Btuh Ducts 2100 Btuh Central vent(56 cfm) 2176 Btuh Heating Cooling Outside air Area(ft�) 1882 1882 Equipment latent load 7345 Btuh Volume(ft3) 16059 16059 Air changes/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 29358 Btuh Equiv.AVF(cfm) 102 54 Req.total capacity at 0.70 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1S036-230C** AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.0 kW Sensible cooling 24220 Btuh Heating output 23827 Btuh Latent cooling 10380 Btuh Temperature rise 19 °F Total cooling 34600 Btuh Actual airflow 1153 dim Actual airflow 1153 cfm Air flow factor 0.052 cfm/Btuh Air flow factor 0.052 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 0.76 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2021-Mar-1 9 11:28:59 M,e• Right-Site®Universal 2021 21.0.03 RSU27054 Page 1 ACCA unerrts\WrightsoftHVAC\5705 Emerson Ave GBl.rup Calc=MJ8 Front Door faces:SW Air Calcs, LLC Right-J®Worksheet Job: 1433 Entire House Date: 3/4/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Entire House Dining Room 2 E)posed wal I 198.0 It 31.5 It 3 Room height 8.5 It 9.0 It heat/000l 4 Room dimensions 1.0 x 179.0 It 5 Room area 1881.5 fF 179.0 fF Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VfJ Block R-9 Wall 0.089 n 2.58 1.65 224 208 536 343 0 0 0 0 C Impact 0.320 n 9.28 7.59 16 0 148 121 0 0 0 0 W Block R-9 Wall 0.042 a 1.21 1.78 11 11 13 20 11 11 13 20 Block R-9 Wall 0.089 a 2.58 1.65 254 185 476 305 142 96 248 158 11 G Impact 0.280 a 8.12 11.50 3 2 21 30 3 2 21 30 Impact 0.320 a 9.28 23.02 46 0 430 1068 23 0 215 534 D Fbrgls Door 0.127 e 3.69 3.73 20 20 74 75 20 20 74 75 W Block R-9 Wall 0.042 s 1.21 1.78 6 6 7 11 6 6 7 11 Block R-9 Wall 0.089 s 2.58 1.65 385 372 959 613 21 21 54 35 Impact 0.320 s 9.28 9.59 13 13 118 122 0 0 0 0 Block R-9 Wall 0.089 w 2.58 1.65 430 350 902 577 0 0 0 0 Impact 0.320 w 9.28 23.02 23 0 215 534 0 0 0 0 Impact 0.320 w 9.28 23.02 16 0 150 373 0 0 0 0 Impact 0.330 w 9.57 26.18 40 0 385 1052 0 0 0 0 P Block R-9 Wall 0.042 1.21 1.78 41 41 49 73 23 23 28 41 P Frm Wall,1/2"Gvp B 0.101 2.94 1.46 304 304 893 443 81 81 236 117 C Attic,Shngl Roof,R 0.034 0.99 1.46 1882 1882 1858 2742 179 179 177 261 F On Grade Depth,Tile 0,989 28,68 0,00 11182 198 5679 0 179 32 903 0 6 c)AED excursion 272 52 Envelope loss/gain 12915 8772 1977 1333 12 a) Infiltration 3241 906 446 125 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 5 1150 0 0 Appliances/other 4350 0 Subtotal(lines 6 to 13) 16156 15178 2423 1458 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 5 7 14 Subtotal 16156 15178 2428 1464 15 Dud loads 38% 46% 62071 6943 38% 46%1 933 670 FFTotal room load 22363 22122 3360 2134 Air required(ctm) 1153 1153 173 111 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-1911:28:59 Right-SuteOUnversal2021 21.0.03 RSU27054 Page 1 .ents WrightsoftHVAQ.5705EmersonAveGBl.rp Calc=MJ8 Front Door faces:SW Air Calcs, LLC Right-J®Worksheet Job: 1433 Entire House Date: 3/4/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Bed Wtrclst 2 E)posed wal I 30.5 ft 0 It 3 Room height 8.0 It heat/cool 8.0 It heaV000l 4 Room dimensions 14.0 x 13.5 It 4.0 x 6.5 It 5 Room area 189.0 fF 26.0 ft Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VfJ Block R-9 Wall 0.089 n 2.58 1.65 24 24 62 40 0 0 0 0 C Impact 0.320 n 9.28 7.59 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 a 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 a 2.58 1.65 112 89 229 146 0 0 0 0 11 G Impact 0.280 a 8.12 11.50 0 0 0 0 0 0 0 0 Impact 0.320 a 9.28 23.02 23 0 215 534 0 0 0 0 D Fbrgls Door 0.127 e 3.69 3.73 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 s 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 s 2.58 1.65 108 108 278 178 0 0 0 0 Impact 0.320 s 9.28 9.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 w 2.58 1.65 0 0 0 0 0 0 0 0 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.330 w 9.57 26.18 0 0 0 0 0 0 0 0 P Block R-9 Wall 0.042 1.21 1.78 0 0 0 0 0 0 0 0 P Frm Wall,1/2"Gvp B 0.101 2.94 1.46 0 0 0 0 0 0 0 0 C Attic,Shngl Roof,R 0.034 0.99 1.46 189 189 187 275 26 26 26 38 F On Grade Depth,Tile 0,989 28,68 0,00 11191 31 1175 0 26 0 0 0 6 c)AED excursion 52 -2 Envelope loss/gain 1845 1225 26 35 12 a) Infiltration 604 169 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 250 0 Subtotal(lines 6 to 13) 2449 1644 26 35 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 2 3 6 8 14 Subtotal 2452 1647 31 43 15 Dud loads 38% 46% 9421 754 38% 46%1 12 20 FFTotal room load 3394 2401 43 63 Airrequired(ctm) 175 125 2 3 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-1 9 11:28:59 Right-Suite®Unversal2021 21.0.03 RSU27054 Page 2 .ents WrightsoftHVAQ.5705EmersonAveGBl.rp Calc=MJ8 Front Door faces:SW Air Calcs, LLC Right-J®Worksheet Job: 1433 Entire House Date: 3/4/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Master Bath WIC 2 E)posed wal I 10.5 It 0 It 3 Room height 8.0 It heaV000l 8.0 It heaV000l 4 Room dimensions 1.0 x 107.4 It 1.0 x 41.1 It 5 Room area 107.4 fF 41.1 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VfJ Block R-9 Wall 0.089 n 2.58 1.65 0 0 0 0 0 0 0 0 C Impact 0.320 n 9.28 7.59 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 a 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 a 2.58 1.65 0 0 0 0 0 0 0 0 11 G Impact 0.280 a 8.12 11.50 0 0 0 0 0 0 0 0 Impact 0.320 a 9.28 23.02 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 e 3.69 3.73 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 s 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 s 2.58 1.65 84 71 184 117 0 0 0 0 Impact 0.320 s 9.28 9.59 13 13 118 122 0 0 0 0 Block R-9 Wall 0.089 w 2.58 1.65 0 0 0 0 0 0 0 0 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.330 w 9.57 26.18 0 0 0 0 0 0 0 0 P Block R-9 Wall 0.042 1.21 1.78 0 0 0 0 0 0 0 0 P Frm Wall,U2"Gvp B 0.101 2.94 1.46 0 0 0 0 0 0 0 0 C Attic,Shngl Roof,R 0.034 0.99 1.46 107 107 106 156 41 41 41 60 F On Grade Depth,Tile 0,989 28,68 0,00 1071 11 301 0 41 0 0 0 6 c)AED excursion -30 -4 Envelope loss/gain 709 367 41 56 12 a) Infiltration 208 58 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 917 425 41 56 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 117 35 0 0 14 Subtotal 1034 460 41 56 15 Dud loads 38% 46% 3971 210 38% 46%1 16 26 FFTotal room load 1431 670 56 82 Airrequired(ctm) 74 35 3 4 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-1 9 11:28:59 Right-Suite®Unversal2021 21.0.03 RSU27054 Page 3 .ents WrightsoftHVAQ.5705EmersonAveGBl.rp Calc=MJ8 Front Door faces:SW Air Calcs, LLC Right-J®Worksheet Job: 1433 Entire House Date: 3/4/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Lin2 Master Bed 2 E)posed wal I 2.5 It 33.0 ft 3 Room height 8.0 It heaV000l 8.0 ft heat/cool 4 Room dimensions 3.0 x 2.5 It 14.0 x 19.0 It 5 Room area 7.5 ft' 266.0 fF Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VfJ Block R-9 Wall 0.089 n 2.58 1.65 0 0 0 0 0 0 0 0 C Impact 0.320 n 9.28 7.59 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 a 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 a 2.58 1.65 0 0 0 0 0 0 0 0 11 G Impact 0.280 a 8.12 11.50 0 0 0 0 0 0 0 0 Impact 0.320 a 9.28 23.02 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 e 3.69 3.73 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 s 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 s 2.58 1.65 20 20 52 33 152 152 392 250 Impact 0.320 s 9.28 9.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 w 2.58 1.65 0 0 0 0 112 89 229 146 Impact 0.320 w 9.28 23.02 0 0 0 0 23 0 215 534 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.330 w 9.57 26.18 0 0 0 0 0 0 0 0 P Block R-9 Wall 0.042 1.21 1.78 0 0 0 0 0 0 0 0 P Frm Wall,1/2"Gvp B 0.101 2.94 1.46 0 0 0 0 0 0 0 0 C Attic,Shngl Roof,R 0.034 0.99 1.46 8 8 7 11 266 266 263 388 F On Grade Depth,Tile 0.989 28.68 0.00 8 3 72 0 266 33 946 0 6 c)AED excursion -4 119 Envelope loss/gain 131 40 2045 1438 12 a) Infiltration 50 14 653 183 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 500 Subtotal(lines 6 to 13) 180 54 2698 2120 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution -180 -54 64 19 14 Subtotal 0 0 2762 2139 15 Dud loads 38% 46% 01 0 38% 46%1 1061 979 FFTotal room load 0 0 3823 3118 Airrequired(ctm) 0 0 197 163 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-1 9 11:28:59 Right-SuiteOUnversal202121.0.03RSU27054 Page .ents WrightsoftHVAQ.5705EmersonAveGBl.rp Calc=MJ8 Front Door faces:SW Air Calcs, LLC Right-J®Worksheet Job: 1433 Entire House Date: 3/4/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Bed 3 Laundry 2 E)q)osed wal I 23.5 ft 6.5 It 3 Room height 8.0 It heaV000l 8.0 It heaV000l 4 Room dimensions 1.0 x 147.0 It 1.0 x 52.3 It 5 Room area 147.0 fF 52.3 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VfJ Block R-9 Wall 0.089 n 2.58 1.65 100 84 217 139 0 0 0 0 C Impact 0.320 n 9.28 7.59 16 0 148 121 0 0 0 0 W Block R-9 Wall 0.042 a 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 a 2.58 1.65 0 0 0 0 0 0 0 0 11 G Impact 0.280 a 8.12 11.50 0 0 0 0 0 0 0 0 Impact 0.320 a 9.28 23.02 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 e 3.69 3.73 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 s 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 s 2.58 1.65 0 0 0 0 0 0 0 0 Impact 0.320 s 9.28 9.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 w 2.58 1.65 0 0 0 0 0 0 0 0 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.330 w 9.57 26.18 0 0 0 0 0 0 0 0 P Block R-9 Wall 0.042 1.21 1.78 0 0 0 0 0 0 0 0 P Frm Wall,U2"Gvp B 0.101 2.94 1.46 88 88 259 128 52 E321 153 76 C Attic,Shngl Roof,R 0.034 0.99 1.46 147 147 145 214 52 52 52 76 F On Grade Depth,Tile 0,989 28,68 0,00 1471 24 674 0 52 7 186 0 6 c)AED excursion -60 -42 Envelope loss/gain 1442 542 391 110 12 a) Infiltration 248 69 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 250 500 Subtotal(lines 6 to 13) 1689 861 391 610 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 80 32 49 24 14 Subtotal 1770 893 440 634 15 Dud loads 38% 46% 6801 409 38% 46%1 169 290 FFTotal room load 2449 1302 609 924 Airrequired(ctm) 126 68 31 48 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-1 9 11:28:59 Right-Suite®Unversal2021 21.0.03 RSU27054 Page 5 .ents WrightsoftHVAQ.5705EmersonAveGBl.rp Calc=MJ8 Front Door faces:SW Air Calcs, LLC Right-J®Worksheet Job: 1433 Entire House Date: 3/4/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Lin3 Lin 2 E)q)osed wal I O ft 2.0 It 3 Room height 8.0 It heaV000l 8.0 It heat/cool 4 Room dimensions 2.5 x 2.5 It 2.0 x 2.5 It 5 Room area 6.3 ft' 5.0 fr Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/fr--°F) (Btuh/fr) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VfJ Block R-9 Wall 0.089 n 2.58 1.65 0 0 0 0 0 0 0 0 C Impact 0.320 n 9.28 7.59 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 a 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 a 2.58 1.65 0 0 0 0 0 0 0 0 11 G Impact 0.280 a 8.12 11.50 0 0 0 0 0 0 0 0 Impact 0.320 a 9.28 23.02 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 e 3.69 3.73 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 s 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 s 2.58 1.65 0 0 0 0 0 0 0 0 Impact 0.320 s 9.28 9.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 w 2.58 1.65 0 0 0 0 0 0 0 0 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.330 w 9.57 26.18 0 0 0 0 0 0 0 0 P Block R-9 Wall 0.042 1.21 1.78 0 0 0 0 0 0 0 0 P Frm Wall,1/2"Gvp B 0.101 2.94 1.46 0 0 0 0 16 16 47 23 C Attic,Shngl Roof,R 0.034 0.99 1.46 6 6 6 9 5 5 5 7 F On Grade Depth,Tile 0.989 28.68 0.00 6 0 0 0 5 2 57 0 6 c)AED excursion -1 -2 Envelope loss/gain 6 9 109 29 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 6 9 109 29 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution -6 -9 -109 -29 14 Subtotal 0 0 0 0 15 Dud loads 38% 46% 01 0 38% 46%1 0 0 Total room load 0 0 0 0 Airrequired(dm) 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-1 9 11:28:59 Right-Suite®Unversal2021 21.0.03 RSU27054 Page 6 .ents WrightsoftHVAQ.5705EmersonAveGBl.rp Calc=MJ8 Front Door faces:SW Air Calcs, LLC Right-J®Worksheet Job: 1433 Entire House Date: 3/4/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Bed 2 Bath 2 2 E)posed wal I 26.5 It 5.5 It 3 Room height 8.0 It heat/000l 8.0 It heat/000l 4 Room dimensions 14.0 x 12.5 It 1.0 x 63.8 It 5 Room area 175.0 fF 63.8 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VfJ Block R-9 Wall 0.089 n 2.58 1.65 100 100 258 165 0 0 0 0 C Impact 0.320 n 9.28 7.59 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 a 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 a 2.58 1.65 0 0 0 0 0 0 0 0 11 G Impact 0.280 a 8.12 11.50 0 0 0 0 0 0 0 0 Impact 0.320 a 9.28 23.02 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 e 3.69 3.73 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 s 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 s 2.58 1.65 0 0 0 0 0 0 0 0 Impact 0.320 s 9.28 9.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 w 2.58 1.65 112 96 247 158 44 44 113 73 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.320 w 9.28 23.02 16 0 150 373 0 0 0 0 Impact 0.330 w 9.57 26.18 0 0 0 0 0 0 0 0 P Block R-9 Wall 0.042 1.21 1.78 0 0 0 0 0 0 0 0 P Frm Wall,1/2"Gvp B 0.101 2.94 1.46 0 0 0 0 0 0 0 0 C Attic,Shngl Roof,R 0.034 0.99 1.46 175 175 173 255 64 64 63 93 F On Grade Depth,Tile 0,989 28,68 0,00 175 27 760 0 64 6 158 0 6 c)AED excursion 87 -13 Envelope loss/gain 1588 1037 334 153 12 a) Infiltration 525 147 109 30 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 250 0 Subtotal(lines 6 to 13) 2112 1434 443 183 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 8 11 9 12 14 Subtotal 2120 1445 451 195 15 Dud loads 38% 46%1 815 661 38% 46%1 173 89 FFTotal room load 2935 2106 625 284 Air required(ctm) 151 110 32 15 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-1 9 11:28:59 Right-Suite®Unversal2021 21.0.03 RSU27054 Page 7 .ents WrightsoftHVAQ.5705EmersonAveGBl.rp Calc=MJ8 Front Door faces:SW Air Calcs, LLC Right-J®Worksheet Job: 1433 Entire House Date: 3/4/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Hall Family Room 2 E)posed wal I O ft 17.0 It 3 Room height 8.0 It heaV000l 9.5 It heaV000l 4 Room dimensions 9.5 x 3.5 It 17.0 x 18.5 It 5 Room area 33.3 ft' 314.5 fF Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VfJ Block R-9 Wall 0.089 n 2.58 1.65 0 0 0 0 0 0 0 0 C Impact 0.320 n 9.28 7.59 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 a 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 a 2.58 1.65 0 0 0 0 0 0 0 0 11 G Impact 0.280 a 8.12 11.50 0 0 0 0 0 0 0 0 Impact 0.320 a 9.28 23.02 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 e 3.69 3.73 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 s 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 s 2.58 1.65 0 0 0 0 0 0 0 0 Impact 0.320 s 9.28 9.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 w 2.58 1.65 0 0 0 0 162 121 313 200 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.330 w 9.57 26.18 0 0 0 0 40 0 385 1052 P Block R-9 Wall 0.042 1.21 1.78 0 0 0 0 0 0 0 0 P Frm Wall,1/2"Gvp B 0.101 2.94 1.46 0 0 0 0 0 0 0 0 C Attic,Shngl Roof,R 0.034 0.99 1.46 33 33 33 48 315 315 311 458 F On Grade Depth,Tile 0,989 28,68 0,00 331 0 0 0 315 17 4118 0 6 c)AED excursion -3 296 Envelope loss/gain 33 45 1495 2007 12 a) Infiltration 0 0 400 112 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 3 690 Appliances/other 0 900 Subtotal(lines 6 to 13) 33 45 1895 3709 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution -33 -45 7 10 14 Subtotal 0 0 1903 3719 15 Dud loads 38% 46% 01 0 38% 46%1 731 1701 FFTotal room load 0 0 2633 5420 Airrequired(ctm) 0 0 136 283 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-1 9 11:28:59 Right-Suite®Unversal2021 21.0.03 RSU27054 Page 8 .ents WrightsoftHVAQ.5705EmersonAveGBl.rp Calc=MJ8 Front Door faces:SW Air Calcs, LLC Right-J®Worksheet Job: 1433 Entire House Date: 3/4/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Hall Kitchen 2 E)posed wal I O ft 9.0 It 3 Room height 8.0 It heat/000l 9.5 It heat/000l 4 Room dimensions 4.0 x 6.5 It 1.0 x 237.5 It 5 Room area 26.0 ft2 237.5 fF Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/R2--°F) (Btuh/fl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VfJ Block R-9 Wall 0.089 n 2.58 1.65 0 0 0 0 0 0 0 0 C Impact 0.320 n 9.28 7.59 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 a 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 a 2.58 1.65 0 0 0 0 0 0 0 0 11 G Impact 0.280 a 8.12 11.50 0 0 0 0 0 0 0 0 Impad 0.320 a 9.28 23.02 0 0 0 0 0 0 0 0 D Fbrgls Door 0.127 e 3.69 3.73 0 0 0 0 0 0 0 0 W Block R-9 Wall 0.042 s 1.21 1.78 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 s 2.58 1.65 0 0 0 0 0 0 0 0 Impact 0.320 s 9.28 9.59 0 0 0 0 0 0 0 0 Block R-9 Wall 0.089 w 2.58 1.65 0 0 0 0 0 0 0 0 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.320 w 9.28 23.02 0 0 0 0 0 0 0 0 Impact 0.330 w 9.57 26.18 0 0 0 0 0 0 0 0 P Block R-9 Wall 0.042 1.21 1.78 0 0 0 0 18 18 22 32 P Frm Wall,1/2"Gvp B 0.101 2.94 1.46 0 0 0 0 68 68 198 98 C Attic,Shngl Roof,R 0.034 0.99 1.46 26 26 26 38 238 238 235 346 F On Grade Depth,Tile 0,989 28,68 0,00 26 0 0 0 238 9 258 0 6 c)AED excursion -2 -172 Envelope loss/gain 26 35 713 305 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 2 460 Appliances/other 0 1700 Subtotal(lines 6 to 13) 26 35 713 2465 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution -26 -35 13 18 14 Subtotal 0 0 725 2483 15 Dud loads 38% 46% 0 0 38% 46% 279 1136 FFTotal room load 0 0 1004 3618 Airrequired(ctm) 0 0 52 189 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-1 9 11:28:59 Right-Suite®Unversal2021 21.0.03 RSU27054 Page 9 .ents WrightsoftHVAQ.5705EmersonAveGBl.rp Calc=MJ8 Front Door faces:SW Air Calcs, LLC Right-J®Worksheet Job: 1433 Entire House Date: 3/4/2021 By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com 1 Room name Lin4 2 E)posed wal I 0 It 3 Room height 8.0 It heat/000l 4 Room dimensions 2.0 x 2.5 It 5 Room area 5.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Load number (BtuhV-°F) (Btuh/fF) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Block R-9 Wall 0.089 n 2.58 1.65 0 0 0 0 G Impact 0.320 n 9.28 7.59 0 0 0 0 W Block R-9 Wall 0.042 e 1.21 1.78 0 0 0 0 Block R-9 Wall 0.089 a 2.58 1.65 0 0 0 0 11 G Impact 0.280 a 8.12 11.50 0 0 0 0 Impact 0.320 e 9.28 23.02 0 0 0 0 D Fbrgls Door 0.127 e 3.69 3.73 0 0 0 0 W Block R-9 Wall 0.042 s 1.21 1.78 0 0 0 0 Block R-9 Wall 0.089 s 2.58 1.65 0 0 0 0 Impact 0.320 s 9.28 9.59 0 0 0 0 VL: Block R-9 Wall 0.089 w 2.58 1.65 0 0 0 0 Impact 0.320 w 9.28 23.02 0 0 0 0 G Impact 0.320 w 9.28 23.02 0 0 0 0 Impact 0.330 w 9.57 26.18 0 0 0 0 P Block R-9 Wall 0.042 1.21 1.78 0 0 0 0 P Frm Wall,1/2"Gvp B 0.101 2.94 1.46 0 0 0 0 C Attic,Shngl Roof,R 0.034 0.99 1.46 5 5 5 7 F On Grade Depth,Tile 0.989 28.68 0.00 51 0 0 0 6 c)AED excursion 0 Envelope loss/gain 5 7 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants@ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 5 7 Less e)demal load 0 0 Less transfer 0 0 Redistribution -5 -7 14 Subtotal 0 0 15 Duct loads 38% 46%1 0 0 FFTotal room load 0 0 Air required(dim) 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� rigF�tsoft° 2021-Mar-1 9 11:28:59 Right-SuteOUnversal2021 21.0.03 RSU27054 Page 10 .ents WrightsoftHVAQ.5705EmersonAveGBl.rp Calc=MJ8 Front Door faces:SW Air Calcs LLC Duct System Summary Job: 1433 Date: 3/4/2021 Entire House By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.mm Project Information For: Clark Residence,Groza Builders,Inc 5705 Emerson Ave.,Ft.Pierce,FL 34951 Heating Cooling External static pressure 0.70 in H2O 0.70 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.70 in H2O 0.70 in H2O Supply/return available pressure 0.541 /0.159 in H2O 0.541 /0.159 in H2O Lowest friction rate 0.311 in/100ft 0.311 in/100ft Actual airflow 1153 cfm 1153 cfm Total effective length(TEL) 225 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bath2 h 625 39 18 0.364 4.0 Ox0 VIFx 28.8 120.0 st2 Bed 2 h 2935 182 132 0.330 7.0 Ox 0 VI Fx 38.7 125.0 st2 Bed 3 h 2449 152 81 0.326 7.0 Ox 0 VI Fx 36.1 130.0 st2 Bed 4 h 3394 210 150 0.317 7.0 Ox 0 VI Fx 45.4 125.0 st3 Dining Room h 1680 104 67 0.328 6.0 Ox 0 VI Fx 39.8 125.0 st4 Dining Room-A h 1680 104 67 0.328 6.0 Ox 0 VI Fx 39.9 125.0 st4 Family Room c 2710 81 169 0.431 7.0 Ox 0 VI Fx 25.4 100.0 st1 Family Room-A c 2710 81 169 0.431 7.0 Ox 0 VI Fx 25.4 100.0 st1 Kitchen c 1809 31 113 0.445 6.0 Ox0 VI Fx 21.5 100.0 st1 Kitchen-A c 1809 31 113 0.445 6.0 Ox0 VI Fx 21.6 100.0 st1 Laundry c 924 38 58 0.364 5.0 Ox0 VI Fx 28.5 120.0 st2 Master Bath h 1431 89 42 0.336 5.0 Ox 0 VI Fx 35.9 125.0 st3 Master Bed h 1911 118 98 0.333 6.0 Ox 0 VI Fx 37.4 125.0 st3 Master Bed-A h 1911 118 98 0.311 6.0 Ox 0 VI Fx 49.1 125.0 st3 WIC c 82 3 5 0.341 4.0 Ox 0 VI Fx 33.7 125.0 st3 Wtr Clst c 63 3 4 0.332 4.0 Ox 0 VI Fx 38.2 125.0 st3 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 PeakAVF 409 289 0.326 751 10.0 0 x 0 VinlFlx st1 st3 PeakAVF 541 396 0.311 689 12.0 0 x 0 VinIFIX st1 st4 PeakAVF 208 133 0.328 778 7.0 0 x 0 VinIFIX st1 st1 PeakAVF 1384 1384 0.311 783 18.0 0 x 0 VinIFIX wrightsoft® 2021-Mar-1 9 11:29:00 A II,-=Iae,-"e--.,I—— Right-Suite(g)Universal 202121.0.03 RSU27054 Page 1 ACCP. ...unents\WrightsoftHVAC\5705 Emerson Ave GBl.rup Calc=MJ8 Front Door faces:SW TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb4 Ox0 152 81 51.2 0.311 343 9.0 Ox 0 VIFx rt1 rb5 Ox0 182 132 51.0 0.312 411 9.0 Ox 0 VIFx rt1 rb6 Ox0 600 820 32.8 0.484 587 16.0 Ox 0 VIFx rt1 rb1 Ox0 240 200 0 0 0 0 Ox 0 VIFx rb2 Ox0 210 150 0 0 0 0 Ox 0 VIFx TableReturn Trunk Detail Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rt1 PeakAVF 934 1033 0.311 585 18.0 0 x 0 VInIFIX Bolditalic values have been manually overridden wrightsoft® 2021-Mar-1 9 11:29:00 A —=ek=Iae,•.--1aw,C—p—, Right-Sute®Uriversal202121.0.03RSU27054 Page ACCP. ...unerts\WrightsoftHVAC\5705 Emerson Ave GBI.rup Calc=MJ8 Front Door faces:SW Manual S Compliance Report Job: 1433 Air Calcs, LLC p p Date: 3/4/2021 Entire House By: Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vickilyme@aircalcs.com Project Information For: Clark Residence,Groza Builders,Inc 5705 Emerson Ave.,Ft.Pierce,FL 34951 Cooling Equipment Design Conditions Outdoor design DB: 90.4°F Sensible gain: 23075 Btuh Entering coil DB: 76.9°F Outdoor design WB: 77.4°F Latent gain: 7345 Btuh Entering coil WB: 64.0°F Indoor design DB: 75.0°F Total gain: 30420 Btuh Indoor RH: 50% Estimated airflow: 1153 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer: Lennox Model: ML14XC1S036-230C**+CBA27UHE-036-230*++TDR Actual airflow: 1153 cfm Sensible capacity: 24220 Btuh 105%of load Latent capacity: 10380 Btuh 141%of load Total capacity: 34600 Btuh 114%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 41.0°F Heat loss: 24158 Btuh Entering coil DB: 68.1°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: Elecstrip Manufacturer: Model: Actual airflow: 1153 cfm Output capacity: 7.0 kW 99%of load Temp.rise: 50 °F Meets all requirements ofACCA Manual S. wrightsoft, 2021-Mar-19 11:29:00 A II,-=Iae,-"e--.,I—— Right-Sute®Universal 2021 21.0.03 RSU27054 Page l ACCk unerrts\WrightsoftHVAC\5705 Emerson Ave GBl.rup Calc=MJ8 Front Door faces:SW