Loading...
HomeMy WebLinkAboutCertification for Design Load ComplianceFife Copy Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: CALATLANTIC - RIVERBEND LOT 4 Project Address: 3010 NW Radcliffe Way Permit #: RIVERBEND LOT 4 Occupancy Type: R3 Construction Type: VB INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida RESIDENTIAL Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 170 mph X ASD LRFD End Zone Width: 7 ft 5. Mean Roof Height 15 ft Roof Pitch: 4 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 43 Zone 2: 68 Zone 3: 99 Zone 4: 45 Zone 5: 45 Garage: 38 7. Design Loads: Floor: NSA PSF Roof/Dead: 25 PSF Roof/Live: 20 Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: MINSHENG XIE 25873 Print Name Cert # & Co. Cert Auth. ASE ENGINEERING SERVICES re, Date, and Seal Revised 07/25/2014 10244 E COLONIAL DR. STE 202, ORLANDO, FL 32817 Company Name & Address