HomeMy WebLinkAboutSewagerue- �opy.A STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION PERMIT FOR: OSTDS New APPLICANT: (Standard Pacific of Florida GP, Inc) PROPERTY ADDRESS: 3010 NW Radcliffe Palm City, FL 34990 LOT: 4 BLOCK: SUBDIVISION: Riverbend PERMIT #: 66-SF-I 764096 APPLICATION #:AP1291313 DATE PAID: FEE PAID: RECEIPT #: DOCUMENT #: PR1062864 PROPERTY ID #: 4425-703-0009-000-8 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 3.81.0065, F.S., AND CHAPTER 64E-6,. F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORYPERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT- IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM, COMPLIANCE WITH OTHER FEDERAL, STATE., OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ _ 800 ] GALLONS / GPD AauaAire AA800 Aerobic Unit CAPACITY A [ 450 ] GALLONS / GPD Pre treatment tank CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ 450 ] GALLONS DOSING TANK CAPACITY [77.00 ]GALLONS @[ 6 ]DOSES PER 24 HRS #Pumps [ 1 ] D [ 576 ] SQUARE FEET Netafim drioline SYSTEM R [ ] SQUARE FEET N/A SYSTEM A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [X1 MOUND [ ] I CONFIGURATION: [XI TRENCH' [ ] BED [ ] N F LOCATION OF BENCHMARK: pop nail in curb N of N PL elev 8.56 I ELEVATION OF PROPOSED SYSTEM SITE [ 0.00 ][INCHES FT ][ABOVE BELOW] BENCHMARK/REFERENCE POINT E BOTTOM OF DRAINFIELD TO BE [ 6.00 ][INCHES FT ][ABOVE BELOW] BENCHMARK/REFERENCE POINT L D 0 T H E R FILL REQUIRED: [ 24.003 INCHES EXCAVATION REQUIRED: [ bb.UU ] INCHES The system is sized fo with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 460 gpd. The licensed contractor installing the system is responsible for installing the minimum category of tank in accordance with s. 64E-6.013(3)(f),' FAC. Performing Lift Dosing. Pumps must be certified as suitable for distributing sewage effluent. NEEDS BIANNUAL OPERATING PERMIT/ME CONTRACT FOR 2 YEARS PE DESIGN REQUIRED SIGN OFF AT CONSTRUCTION FINAL (Designed by Todd N Smith) SPECIFICATIONS BY: Brian Davis TITLE: Master Septic Tank Contractor APPROVED BY: TITLE Environmental Specialist II St. Lucie CHD Brian J Ingram. - DATE ISSUED: 05/24/2017 EXPIRATION DATE: 11/23/2018 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.00.3, PAC Page 1 of 3 v 1.1.4 AP1291313 SE1035232 NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way,. BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile number'is 850-413-8743. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a'final order. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, .Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. St. Lucie County Health Department HEALTH 5150 NW Milner Dr Port Saint Lucie, FL 34983 ALTH PAYING ON: PERMIT#:56-SF-1764096 BILL DOC #:56-BID-3433378 CONSTRUCTION APPLICATION #:AP1291313 RECEIVED FROM: The Milcor Group, Inc. AMOUNT PAID: $ 400.00 PAYMENT FORM: CREDIT CARD PAYMENT DATE: 05/18/2017 MAIL TO: (Standard Pacific of Florida GP, Inc) FACILITY NAME: PROPERTY LOCATION: 3010' NW Radcliffe Palm City, FL 34990 Lot: 4 Block: Property ID: 4425-703-0009-000-8 EXPLANATION or DESCRIPTION: QUANTITY FEE -1 - OSTDS Construction Application and.Plan Review,New 1 $ 100.00 126 = OSTDS Construction Permit (New or Mod, Amendment) 1 $ 55.00 127 - OSTDS Construction System Inspection 1 $ 75.00 128 - OSTDS Construction System Inspection Research Fee 1 $ 5.00 133 - OSTDS Construction Reinspection 1 $ 50.00 -1 - Surcharge (All) 1 $ 15.00 -1 - OSTDS New Permit Surcharge 1 $ 100.00 RECEIVED BY: VanceMH AUDIT CONTROL NO. 56-PID-3242910 E oSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: PERMIT 140.5(q �5!<'• 1710 y�9 DATE PAID.: FEE PAID: RECEIPT #: [X ] New System [ ] Existing System [ '] Holding Tank [ ] Innovative [ ] Repair [ ] Abandonment [ ] Temporary [ ] APPLICANT: Standard Pacific of Florida GP, Inc. AGENT: The Mi1Cor Group, Inc. TELEPHONE: 772-223-8850 MAILING ADDRESS: 6526 S Kanner Highway, Stuart, FL 34997 TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LfCENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES.. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION LOT: 4 BLOCK: SUBDIVISION: Riverbend PLATTED: Yes PROPERTY ID #: 4425-703-0009-000-8 ZONING: PUD I/M OR EQUIVALENT. [ Y / N ] PROPERTY SIZE; ACRES WATER SUPPLY: [ ] PRIVATE PUBLIC [ ]<=2000GPD [. ]>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ Y / N ] DISTANCE TO SEWER: FT PROPERTY ADDRESS: 3010 NW Radcliffe Way, St. Lucie County, FL DIRECTIONS TO PROPERTY:East on Becker Rd. for approximately 2.5 miles to Gilson Rd. Then north on Gilson Rd. for approximately a mile. Then East on NW Radcilttay. BUILDING INFORMATION Unit Type of No Establishment 1 Single Family 2 [ X] RESIDENTIAL [ ] COMMERCIAL No. of Building Commercial/Institutional System Design Bedrooms Area Sqft Table 1, Chapter 64E-6, PAC 4 3688 4 ,�, �. .... ....••.•; 0 [ ] Floor/ qu . D ains [ Other ( Specify) SIGNATURE: . e to DH 4015, 08/09 (Obsoletes previous editions which may not be uset���'•, Incorporated 64E-6.001, FAC �i �iQ•'' • • ' Q 1 of 4 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATIONS PERMIT i APPLICANT: AGENT: f iOT:f BLOCK: SUBDIVISION: PROPERTY ID t: 4 y �'� 707 �UG?Y ' C� t� [Section/Township/Parcel No. or Tax ID Number] TO BE COLLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR. OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND:SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN. [A' YES [ ] NO NET USA78'�S ��:i � / ACRES TOTAL ESTIMATED SEWAGE FLOW: �/vu GALLONS PER DAY [s�r•.F _1/O„THTHER-TABLE2] AUTHORIZED SEWAGE FLOW: f �rCa7 GALLONS PER DAY [1500 GPD/ACRE O 2F00 GPD7XtZM] UNOBSTRUCTED AREA AVAILABLE,: SQFT UNOBSTRUCTED AREA REQUIRED: Ora SQFT BENCHMARK/REFERENCE POINT LOCATION: PC i�../�/}' .? + 'U [_ �.� ' �/ ;r �41' /1 �% { (R. �� 1— C.�P_ C,;• fsjj L I ELEVATION OF PROPOSED SYSTEM SITE IS [ZNCHWAMZ ' [ABOVE/BELOW] BENCMdARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM T PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: a-w FT DITCHES/SWALES: IN, FT NORMALLY WET? [. YES [ ] NO WELLS: PUBLIC:��FT LIMITED USE:�N.�FT PRIVATE: N.' FT NON -POTABLE: N'� FT BUILDING FOUNDATIONS': s FT PROPERTY LINES.: FT POTABLE WATER LINES:.�FT SITE SUBJECT TO FREQUENT FLOODING: [ ] S j11 NO 10 YEAR FLOODING? [ ] YES ],-No 10 YEAR FLOOD ELEVATION FOR SITE: „�l/�—FT MSL/NGVD SITE ELEVATION: i7 FT MSI;/NGVD 3yiL rAy9'.LLAz imi MUNSELL #/COLOR t 2 L t ` C JliMwxlUN SITE 1 TEXTURE r,( f, 5 TO TO. TO TO TO USDA SOIL SERIES: 5 r •L v > ,,t�— SOIL PROFILE INFORMATION SITE 2 MUNSELL #/COLOR TEXTURE DEPTH d ii y( ;',7 TO / y 75 TO TO TO TO USDA SOIL SERIES: OBSERVED WATER TABLE: INCHES [ABOVE /:BELOTr]%EXISTING GRADE. TYPE: [PERCHED �'1A§fil NT] ESTIMATED WET SEASON WATER TABLE ELEVATION: INCHES [ABOVE /e, Wj) EXI9 �G-GRADE HIGH WATER TABLE VEGETATION: [ ] YES [A. NO MOTTLING: [. YES [ ] NO DEPTH: /, INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: � . �!5 DEPTH OF EXCAVATION: t='� INCHES DRAINFIELD.CONFIGURATION: (W TRENgH j ] BED, [ ] OTHER (SPECIFY) i -11.i - -vim,-f F= f e-, " ,..i 7 r ice. `1 • V .� SITE EVALUATED BY: �_ f [ t1F�t- ,�V �i 'z' A4 C%J2 t I*�J ATE: ,Ei ` DR A015, OB/09 (Obsoletes previous editions which may not be used) incorporated: 63_ G1; FAC.:�qg 3 of 4 ��fl1f111111��� Property Card Page 1of1 5 =5 -174 'Of, & Michelle Franklin, CFA — Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: 3010 NW Parcel ID: 4425-703-0009- Account #: 176824 Sec/Town/Range: Radcliffe WAY 000-8 25/34S/40E Map ID: 44/25S Zoning: PUD Use Type: 0000 Jurisdiction: Saint Lucie County Ownership Standard Pacific Of Florida 15360 Barranca PKWY Irvine, CA 92618 Legal Description RIVERBEND (PB 67-36)- LOT 4 Current Values Historical Values 3-year Just/Market: $73,300 Assessed: $59,950 Year Just/Market Assessed Exemptions Taxable Exemptions: $0 Taxable: $59,950 2016 $73,300 $59,950 $0 $59,950 2015 $54,500 $54,500 $0 $54,500 - 2014. $54,500 $54,500 $0 $54,500 Sale History Date Book/Page Sale Code Deed Grantor Price 11-26-2012 3460 / 0152 0205 SP Stuart Property Holdings Ltd, $7,000,000 Primary Building Information Finished Area of this building: 0 SF Gross Area of this building: 0 SF Exterior Data View: Year Built: N/A Primary Wall: Bedrooms: 0 Full Baths: 0 Half Baths: 0 Type Roof Cover: Roof Structure: Building Type: Frame: Grade: Effective Year: 2014 Story Height: No. Units, 0 Secondary Wall: Interior Data A/C %: 0% Electric: Primary Int Wall: Heated %: N/A% Heat Type: Avg Hgt/Floor: 0 Sprinkled %: 0% Heat Fuel: Primary Floors: Total Areas Finished/Under Air 0 (SF): Gross Area (SF): 0 Land Size (acres): 0.44 Land Size (SF): 19,166 Total Building. Count: I Special .Features and Yard Items Qty Units Year Blt This information is believed to be correct at this'time but it is subject to change and is not warranted. 0 Copyright 2017 Saint Lucie County Property Appraiser. All rights reserved. ittp://www.paslc.org/RtCard/ 5/18/2017 _ FA �5re c�q�9� 5 System Design Criteria for Standard Pacific of Florida 3010 NW Radcliffe Way, Port St. Lucie, FL 34983 (Lot 4, Riverbend 'PUD) Aerobic Treatment Unit With Drip Irrigation Prepared By: Todd N. Smith, PE, Inc. 914 20" Place Vero Beach, F132960 772-559-3699 I certify that the engineering features of this aerobic treatment system have been designed or specified by me and conform to engineering principles applicable to such projects. In my professional judgment, this system, when properly constructed, operated and maintained, will achieve the established performance standard and comply with all applicabl ``s�tM of &State of Florida and the rules of the Department. N. Sm-&, PE '"i1.0ftiowx 82 Drip Design Calculator Job Name/Homeowner: Standard Pacific of Florida Address: 3010 NW Radcliffe Way, Port St. Lucie; FL_34983 Permit Agency _St. Lucie County Health Department Installer Name Brian Davis Sgptic Designed By: _Todd N. Smith, PE, Inc. Date: Mav 15 2017 Gallons Per Day: 460 gpd Soil Loading Rate (GPD, Per Sq. Ft.) 0.8 Recirculation Rate: 14.68 gpm Minutes Per Dose 15 Emitter Spacing (ft.) 1 Sq. Ft. of Application Area 576 Drainfield Reduction: 0% Linear Feet of Tubing 288 Number of Emitters 288 Linear'Feet of Tubing Per Zone 288 Number of Zones 1 Emitters Per Zone 288 Drip Rate (GPH) .90 Gallons Per Minute Per Zone 4.32 Minutes Per Day Per Zone 107 Doses Per Zone 6 Total Doses Pei,Day 6 Time Between Doses in Hours 3.70 Total Run Time in Minutes . 107 Maximum Connections to Manifold 8 Gallons Per Dose 76.7 Total Dynamic Head Calculation (TDH = Static Head + System Operating Head + Dirty Filter + Total Friction Head) Static Head— 5:42 ft. System Operating Head (29 psi) = 67 ft. Dirty Filter = 11.5 ft. Friction Operating Head Header Diameter = 1.00 in.. Type of Fitting Eq. Length Quantity 1" Std. Tee 1.7 ft. 6 1" 90 Degree STD Elbow 5.3 ft. 2 1" 45 Degree 1.4 A. 2 Total Fitting Equivalent Length = 27.0 ft. Actual Length of Discharge Pipe = 122.0 ft. Total Pipe Length = 149.0 ft. Total Friction Losses in 1" diameter discharge line Total Eq. Length 13.6 ft. 10.6 ft. 2.8 ft. GPM HI in ft/100ft HI of 149' of 1" Dia. Static + Operating Head + Dirty Filter Total Discharge Head (ft.) 0 0 0 83.92' 83.92' 15 11.70' 1 17.43' 1 8192' 1 101.35' 20 18.90' 1 28.16' 1 83.92' 1 112:08' Use Sta-Right S.T.E.P. Plus D-Series 4" Submersible Pump (20 gpm — % HP) Pump Curve shows 18.0 gpm @ 108 ft. of head System needs 4.32 GPM Recirculation 18.0 GPM - 4.32 GPM =13.68 GPM Residential: 460 GPD Maximum Lot Flow 1,325 GPD (On Public Water - Lot Area=19,332 SF All. Lot Flow=19,332 SF) / 43,560 sf/acre x 2,500 gpd/acre =1,109 GPD Drip Area Required: 575 sq. ft. Drip Area Provided: 576 sq. ft. Obstructed Green Area Required: 864 sq. ft. Unobstructed Green Area Provided: 1,000 sq. ft. System Design Criteria Residence is Bedroom (4,050 sf > Habitable Area > 3,300 sf) = 460 GPD Drip System to be placed in Trench System 460 GPD / .8 GPD per sq. ft. = 575 sq. ft. of drainfield 0% drainfield reduction for aerobic treatment standard 64E6.012(2)h Drainfield Requirement = 575 sq. ft. of drip irrigation 6 Lines at 48 feet long with emitters every foot and lines greater than 24" apart 288 emitters in 4 loops x 2 sq. ft. per emitter = 576 sf Conti2ency Plan 1. At high water level,: the system will start,alarm. The owner must contact the maintenance entity within 24 hours. 2. Maintenance entity personnel will inspect the system and make necessary repairs within 36 hours as per 64E-6.012(4)(b). 3. Owner shall pump the tank as required to keep trash out of the aeration chamber. Operation and Maintenance The operation and maintenance manuals are provided to the installer and maintenance entity at ihe.time of installation. Installation Installation instructions will be provided by Brian Davis Septic on site to insure proper construction and installation. DRIP EFFLUENT DISPOSAL SYSTEMS DESIGN :CRITERIA - Dated May 15, 2017 Drip effluent disposal systems shall be permitted as an alternative drainfield option for use in Performance -Based Treatment Systems in the State of Florida. The following criteria apply. Florida registered professional engineer shall design all drip effluent disposal systems and the design shall include and consider the following: 1. Drip effluent disposal systems shall be considered performance -based treatment systems. 2. Effluent for drip effluent disposal systems shall be pre-treated to reduce both the 5- day Carbonaceous Biochemical Oxygen Demand (CBODs) and the Total Suspended Solids (TSS) to each be less than 20 mg/1(Secondary Treatment Standards). 3. The infiltrative area required shall be the sameas the area required for a mineral aggregate drainfield with reductions all for the reduction of CBODs and TSS as noted in the Florida Administrative Code, Chapter 64E-6 Part IV, Performance - Based Treatment Systems. 4. In a bed configuration, the drainfield area shall be calculated as extending one foot beyond the sides of the outermost emitter lines. 5. In a trench containing a single distribution line, the drainfield area shall be calculated as 2 feet x the emitter spacing in feet x the number of emitters. 6. Drip effluent disposal systems shall be considered pressure distribution systems. 7. Head loss calculations shall be provided to insure proper hydraulic pressure at the emitter. 8. Pump selection shall be indicated in the design specifications. Pump ,performance curves shall be provided. 9. Re-circulationrates shall be indicated on the drawings. 10. Check valves, petcocks, inline filters, and vacuum breaking device locations shall be indicated on the drawings. 11. Drip effluent disposal systems shall be time -dosed over the 24 hour period. Demand control dosing shall override timed -dosing in periods of flow where timed dosing cannot handle the excessive flow. 12. All drip emitter systems shall be designed as continuous loop circuits with no dead- end emitter lines. All systems need .to incorporate a mechanism for backwashing or flushing. 13. Drip effluent disposal systems shall meet the following operating parameters: Minimum operating pressure at the emitter head shall be 10 psi. * Maximum operating pressure at the emitter head shall be 45 psi. * Maximum system operating pressure shall be .60 psi. * . Maximum discharge rate per emitter shall be 1.5 gallons per hour. 14. Drip emitter lines shall be drawn to scale and drip emitter spacing shall be indicated on the drawings. 15. 'The maximum emitter longitudinal spacing on a distribution line shall be 2 feet. The maximum distribution line spacing in a bed configuration shall be 2 feet. 16. The 24 inch separation from the seasonal high water table shall be measured from the emitter orifice. 17. Setbacks shall be measured from. the drip emitter lines. 18. There is no drainfield sidewall in a drip -effluent disposal system. The'definition of a filled system in a 64E6.002(24), Florida Administrative'Code, is not applicable to drip effluent disposal systems. A drip effluent disposal system is considered to be a mound system when any part of the bottom surface of any drip emitter line is located at or above the elevation of undisturbed native soil in the drainfield area. A drip effluent disposal system us considered a standard sub -surface drainfield system when the entire bottom surface of every drip emitter line is installed below the elevation of undisturbed native soil in the drainfield area. 19. For mound systems there shall be a minimum separation of 18 inches between the shoulder of the fill and the nearest drip emitter line. Mound system slopes shall be in accordance with s. 64E-6.009(3)(f), Florida Administrative Code. Mound systems shall be stabilized in accordance with s. 64E-6.009(3)(f), Florida Administrative Code. 20. For standard sub -surface systems, the elevation of any fill covering the drainfield shall extend no less than 18 inches away from all emitter lines before tapering down to natural grade.. 21. Minimum cover on the distributions lines shall be 6 inches for standard sub -surface systems and 9 inches for mound systems. The maximum cover for all systems shall be no greater than 12 inches. 22. The system shall include a petcock on the dosing pump discharge line for effluent sampling in lieu of the installation of monitoring ports required in s. 64E-6.029(2), Florida Administrative Code. 23. All on -site sewage treatment: and disposal systems that include a drip effluent disposal system shall have an annual operating permit, maintenance contract with an approved performance -based system maintenance entity and shall be inspected in accordance with a 64E-6.027(5), Florida Administrative Code. 24. Manufacturers of drip effluent disposal system distribution lines, emitters, and components shall apply for and. obtain approval for specific model numbers or part numbers prior to inclusion of the components on any site specific permit application. 25. Manufacturer's of.drip effluent disposal system components shall provide design and installation manuals for engineering and construction guidance. Design manuals shall include tables that detail flow rates vs: pressure and pressure loss per length(s) of distribution pipe. Answers for Drip Effluent Disposal Systems Design Criteria for the State of Florida Dated May 15, 2017 1. Compliance 2. 2.9 mg/1'CBOD5 - 4.43 mg/l TSS (30 day effluent average - ANSINSF Standard 40) 3. Compliance 4. Compliance 5. Compliance 6. Compliance 7. Head Loss Calculations Provided Pressure Loss in 149.0 feet of V tubing-& dirty filter is 15.31 psi. Pressure Loss in return line = 5.16 psi Flow Rate while the system is running is ' 18.0 GPM. Pump is capable of producing 18 GPM at 108 ft. of head Pressure to field will be adjusted to achieve a maximum of 30 PSI on the supple manifold byopening the by-pass petcock located in the pump tank. 8. Pump Curve attached 9. 18.0 GPM, filter flush return line, 4.32 GPM during field flush, 13.68 GPM in pump tank. 10. Located in Headworks. 11 Compliance 12. Compliance 13. Minimum operating pressure at emitter head is greater than 10 psi Maximum operating pressure at emitter head is less than 45 PSI Maximum system operating pressure is less than 60 PSI Maximum will be .90 GPH per emitter. 14. Compliance 15. Compliance 16. Compliance 17. Compliance 18. Compliance 19. Compliance 20. Compliance 21. Compliance 22. Compliance 23: Compliance 24. Completed with FDOH 25. Drip Manual given to Installer and Engineer i Pentair Model S.T.E.P. Plus-D Series 4" Multi -Stage Submersible Effluent Pump Stainless Steel Uj w U_ Z J O R CAPACITY LITERS PER MINUTE 'Inn 0 25 50 75 100 200 0 4 5 I'l 30 45 CAPACITY GALLONS PER MINUTE Specifications so V) W W 60 w Z Z 40 ° W 20 0 60 Body Construction: Stainless Steel (3.00 Grade,). Horsepower: Y HP Maximum Head: 225' Maximum Capacity: 40 gpm (model dependent) Flow At 10' Lift: model dependent Switch: None ,Motor: Drywirournd; doublet4ll,"bearing, double sea,l:and thermal overioad`protectlon, UL and CSA zpproved. Impellers: Precision. molded Acetal for perfect balance ... ultra -smooth for the highest performance and efficiency. Allows for .080" solids Diffusers: Polycarbonate 2'/2 AgUaAlre Sewage Treatment System Models AA500,60017505 800,1000, 1200, 1500 In One piece Tank with Lid Alternate Aerator Locations Aerator �!— —i, -�► 314" Schedule 40 PVC not more than 100 LF from Plant 7f 21/z" Schedule n Clarifier Volurne A r•r+ovu t)UUUIfU 1.50. 857 642 21r AA750 750GPD. 1.85 1076 801 27° AA1000 1000GPD 2.50 1420 1063 557 AA1500 1500GP0 3.75 2216 ' 1699 51? AA800 OOGPD 2.0 1155 858 Zg7 AA1200 1200GPD 3.0 1751 1300 1 451 Inlet Tee sembl Mile' Into ,,,ra -- Aerati"U!ine 2'/z" CompClarifier D. F--t� Ctr.Ctr. Dim. it Drop 3" .."ir Deflection 3t, Disc "Extend 10" into liquid depth on AA1500 B C D E F G H 71 64 60 63 .18'/.45.55 80%Z 64 60 63 21'/ 52% 55 100' 64 60 63 29% 643 55 114 64 71 74 35'/'71% 55 134 74 71 74 37'/e 89'/ 65 87 66 71'/Z 74'/. RYT 55'/ 57 89. 77 86 89 24'/ 57'/ 68 3" 9". Eoslogical Tarns, Inc. Maus i DRIP FZELl CROSS SECTION FT* OF DRIP TUBE � UNEB . 2E" CENTERS M9TH ECdBMERS EVERY ; S FOOT i \ O INSTALL DRIP TUBE 6" - 9" BELOW MWAL GRADE WSWT IS >24" Below Emitters SnpplyLines Effective Sell Depth -42" Below `Emmitters Supply Line Length Varies / Return MPanifold I" dia. LFT Return Line I"dia to Pump Tank Supply Line I" die. I" din from Pump Tank XW-CAL 2R-ZE TRENCH YSTF1�l (efts), jo aced i i � aos 4r1 py .. P fi�4l9��97was�d p� sq�gta W16,P Q eo�1lY'l D9Y� itJ wtb � ro� �_ ��, � c� _ '�{ � , APPLICANT'S NAME: standard Pacific of Florida GP, Inc. LEGAL DESCRIPTION• Riverbend (PB 67-36) - Lot 4 I certify that there are no potable private wells within 75 feet of the available area for the proposed septic system; that there are no non -potable wells within 50 feet of the available area for the proposed: septic system, that there are no wells within 25 feet of a pesticide -treated building foundation, that there are no public wells that serve less than 25 people or less than 15 homes or businesses within 100 feet of the proposed septic system, that there are no public wells that serve more than 25 people or more than 15 homes or businesses within 200 feet of the proposed septicsystem,.that the water line from the water meter or well to the structure is at least 10 feet from the available area for the proposed septic system unless the plans show the line to be double sleeved, that there is not a gravity sewer line, low pressure sewer line or vacuum sewage line in a public easement or right-of-way that abuts the property, that there are no lakes, streams, wetlands, or surface water within 75 feet of the available area for the proposed. septic system unless the property was created prior to 1972, that the septic system is proposed on the side of the lot farthest. from surface water, that all private wells, septic systems and surface water on adjacent or contiguous land within 75 feet of the applicant's lot are shown on the site plan, that all .public wells within 200 feet of the applicant's lot are shown on the :site plan, and that the location of building or residences, swimming pools, recorded easements, paved areas or driveways, sidewalks, the general slope of the property, filled areas, drainage features, and surface waters such as lakes, ponds, streams, canals, or wetlands are shown on the applicants lot. The natural grade elevation in the area of the proposed septic system and the benchmark must be shown on the site plan. Please locate the benchmark within 200' feet of the proposed septic system. ° *•••MF�;'�. r%ova w C,) `I •�j i. �.• m: fn• NOTE: MUST BE CERTIFIED BY A FLORIDA REGISTERED SURVEYOR OR ENGINEER. docs/forms/scptics/ScpticAppoPagc207 REPRESENTATIVE AUTHORIzATION Riverbend Subdivision .Please be advised that the undersigned has authorized the following persons) to act on their behalf in seeking approval for the above referenced application: Witness: Melissa G. Corbett, P.E. The Milcor Group, Inc. 6526 South Kanner Highway 4236 Stuart, Florida 34997 (772)223-8850 B t Name Print Name ACKNOWLEDGEMENT STATE OF l � (V C` COUNTY OF The foregoing was acknowledged before me this day of 20 (< by _ �^T�s� N C0c) , and Kj is-personaIly known to me or [ ] has produced as identification. (LZI / Notary Stamp Notary Public [1407) SIVAN SHACHAR MY COMMISSION #FF00702G EXPIRES April 10. 2017 308,0159 FlorldallolarySoM00.00m May 16, 2017 Via: Hand Delivery Melanie Vance St. Lucie County Health Department 3855 South US Highway #1 Fort Pierce; Florida 34982 Re: Riverbend - Lot 4 Septic System Permit Application Dear Ms. Vance, Attached please find an application, for single family residential septic system permit,. including the following documents: gned and sealed Applicat>on for onstruction�'emut`(DH-4Uf5-Page 1 of 4); 2. Signed and sealed Site Evaluation and System Specifications (DH 4015 Page-3 of 4); 3. Signed and sealed System Design Criteria; 4. Signed and sealed Septic Site Criteria; 5. Representative Authorization document; 6. Three (3) 11 x 17.signed and sealed lot.Site Plan;. 7. Three (3)11 x 17 Floor Plan; and 8. Application fee of $400.00. If you have any questions, please do not hesitate to call me at (772) 223-8850. Sincerely, The Mil Qor r up, Inc. <: , If06 3� 0 ,`���o�gg Melissa G. Corbett, + Z �y President = D o '.:.. 'X4 Enclosures ��`,p•., v �o .-L Cc: Philip Darling 1 ��;r 33Q— PAProjects\S 12 - Standard Pacific\S1204 - Riverbend\pennitting\Septic\Lot 4\SLC Health Dept Lot 4 septic app submittal cover lettec.docx 21/2 L ��® with 350 (Mallon FPe4eeatment Tank (Mm1L Pocks With Lod 102" —63" Alternate Aerator Locations Aerator- o� 3/4" Sch Jule 40 PVC not more_th 100 LF Ecological Tanks, Inc. Assemb"9 � � �� �21" T ICeI I � Li Into 0 u+. Y yp Liquid 350 GAL. Pretreatment Tank 29 Y4" 560 GAL. AerationlMixing Compartment -7Y21' 188 -GAL. Clarifier / Center Dim. 2 it Drop Line 3:' 2%2" it Deflection 5"�' ' A 3" 5�� Disc a 03/2002 n Outlet CORKS II R E THE 6811 MODEL FOR: STANDARD PACIFIC HOMES O Making You Right At Home 325 CORAL RIDGE DR. CORAL SPRINGS, FL 33701 Ta (954) 61 73 . srnre aP naww cemNren BBunaB cBNnucros sp.Pr. cAu.•s INDEX OF DRAWINGS SHEET q DESCRIPTION BTANCRPMCITIC.N 025 CORAL M.,E DA, CORM. CORSPPINC9 FL 9T01 rek (B91) 6>e->300 AjjW BMWp; M—Ur® n✓.�. Co u� m a�u ortw PROFG^BIONAL MORTCCli P CMB2LL AR Na. 20>0 AR N1 — C.. CROUP. INC. IAM0N000.RORIOA OZleO BLVB. Trt NW) »�-eOiB � w 's C U l0 n Am«ncu won uV U c�i � fn = U x m otS •V ,O N RtAI vvmow` m em. mrm�ir"" rn (rertL _ •A. _ rt wmevrut row ro �AnLLL, mB J O) 0) y �° fi e°�iae AM mimB_C o a Q 0ON A __­771 L OCK �j RIVERBEND LOT 14 D330�ODA VORKSHIRE 'PLAN E' OBII ELEV. A' ftICNT«� COVER PACE a xm ¢ ag a m a; Q ��0 o _. °�....................._.....,.,wig ...............o.� ►J °III _ ��%��• ���01 � - II� �a a� �8g8g J0 Ui gg A JJC a 33ff U I I rvu®\ 1 LOT 5 1 � � ommTmJ � uonynrl. Ar 'aw:o:a•+�wir1p°' II mrxm' �x...,DDOen ,,..r.P,omrde,.• / a caxsr. Tme N87'55'30 W ( R. 6566' wvam I wRe U, L __ seD7exr e o0 1 �,P,,,a, Vxl >, � ----- -g 1. ° �' 'gy.�^gLTa�t• •n PA_ �� 1P \\ m FO � � 6�� \\ Jy94 • ?-4 4 R \ »xIX �opaca x WP. - EE�{{{a DAAA4 RARIT Elm \ PRBPo9m�tl�To os \\ \ — __—__—__—�NEP�OOA �s• QO . �es3gsoT N86'17'58•E45.91'1b�310• W.M.T.-1 L (eATot VANMEWNT ISAn 1. ALL ELEVATION SHONN ARC IN NAVO nB DATUM. 2 'TELA rL00D-ZONE M. m AquaAlro.Saw• a TFoatmant In Modals AA600,800,750. 600 1000, 12D0, 150016001n Ono PI¢ca Ton vNN Ytl >r Sd-V. M. LAN➢S'SHOVN NEREm KRE NOT ABSTRACTOR FOR RICM-OF-VAT AND/OR EASEMENTS OF RECORD, S. SEPTIC —S AN➢ VELLS S SIOVIx ARE APPRO%IMAIE LOCATIONS AIR) TIELLD BE FIELD VWFIED nr cmR.— rm CORRECT POSTE= AND SEPARATOIN WCRRRDWD UTILITIES m FWTERS NAVE NOT BEEN LOCATED, I, REARING S AND DISTANCES SNDVN MREM SUBSTANTIALLY ACRES VTIH THE PLAT UN-DIS OTHERVISE NOTED 7. THE BFARJAO SYSTEM SNDVN NEREDV JS EASED ON OE LIVE DDNCA7EDDASED ON RECORD DPOPJmTJAN V.W D FROM.P r OR mm & ALL DISTANCES SIOVN NEREOI ARE IORIDINTAL m010 DISTANCES AND ARE REFERENCED TD u3.OPAxmRn IEASURE SURVEY FEET A THE PRO'OSEO INPROVEMEMws.S SMOVN HER[@! ➢11 NOT REPRESENT TIE FINAL IESIGN UNLESS APPROVED DY INC COVERNIIO 10TNICSALITIET. ID ACCSIRMO TO TIE IRTIDNAL FLm➢ INSIIRNICE RATC NAP NUMBER 1P1IWO .L DATED FC➢RWRY 76 EDS' Tt6 ADEIVC DCSCRIDED PRLPERFY L7E5 IN ZOE X. 11 7HE PROR& EYVATIONS M.N DRAINAGE FLOW PRRDVS'S SHO.' IERCDI VCRE FDOH in St. Lucie County CERTIFICATION: DRAINFIELD: SPECIFICATIONS �j Environmental Health IxEReBvcERmrTxxrTxe PN°wffxxDPeATunESDF TxeAErs°aeTnPATlmrtsysTPalNA.s DRAvaELDs� IFUD • snsa Gr, \/ Site Plan Approved for Construction UIN DE—EDORSP-0 BYMAwcoNEaw7oEsn:xwETRwDPRwcDrFSApPIrwmDM UNDesTRUCTEDARE.AREaD. msso. GE °NDDITRUCTEDARPAPRDVnED-LmDsaF. �/ \ yp;NpRD1ECTS.WN/PROiESSLNAL.DGE4EM.TMSSr3TERVMENPROPERLVOONSITUSTED, AMENS N6E6 A6LSNEDPFA DRWNCES ANMRDAID Supersedes All Previous Site Plans for P e mlv LDlE9 PIAV0FD®mFr. NEB roHIAVEDREATERTH.W SIO RATFIN r LAPP" comarvmmuLAP�P19rNVITEaoETxe sureop aaROAArmTIreRDIU DPTxE D v YJ ON6 FMDRERMSO.CKx6FA]MITTER•67'J DGdmWFEL➢PRUVICE9 \� OSTnIYS'#%M Sr' O & &Well# \\\ \ � Rate:5 a 17- 52'arS-dS-t7 Reviewer. ODUN.QB N,PB FE NC�IEiens ;16 �45¢e,ENiL�Rxddgo82 - NUT Va*,PUTTNE SKI*iUREANONN5FA4_OFAFLIXiDAIK£NSEDENGPFER • LOT 4 RIVERBEND L➢Gexo AAe n➢xs EV. • EIOE OF vATER P.R. • PLAT D GTATE .: m nA1R • WAOWAm DOIDItONERPAD F • FIELD OBSERVATION Pa' FONT I TyR {OE- V,. ECDN VAULT SCALE 1• • so' 3010 NW' RADCLIFFE WAY TODD N. SMITH, PE, INC. E S6 PeeARNcs FJt • FIRE MnRgNT PEL .:1IM a ICINP g untD«tpB .'� .pTEITr EMEHENT e FIR. PRoD DEvcNm Dr. tns ST. LUCIE .COUNTY, FL ca"` "uiai'6°LBw�O"P¢ FOUNDND Om P1 miff o<IIi(3 " \\�IUTTILITY RISER ONAt. REVISIONS BY DATE 974 20TH PLACE VERO-BEACH, FL. 32960 DAL •CONCRETEw UEM FNL • FOND PL. • PROPERTY Et II \ VAIER WIER Cim -CK—U n7EDR I'm RL •CONE ELECTRICN. PAD Pao MINT OF D6GINde 1111(Vyt�D. Tp �PDVvpLERvPOLE 4V. - WTI VALK' P8C Mi. o' COMIENCE DRAWN SY:'.MS Ph. (772) 559-3699 CWC • E 1 IRG, - IRm ROD'VITN CAPPRL • PONT OF REVERSE CIIRVATLIE RADIUS IRf° - MEASURED P.T.ATION • IESCT ` CENTRAL ANGLE ;AEI ENC. PROJECT 117731 PMINT IIBLICmUTILITµ c°OPP' .mRRUUR _TCCPM • FROM DEMMSCRiPT N/D MAIL VITN DISK R FROM THE RECORD •CFMEPWO DATE: MAY 2017 tnspe@bellsouth.net DE •IXm11NGE EA ENEM Dx.V. • DVERIEAO MIRE RCP. • REINFORCED CmCRETE PIPE •WRNFA MO.— DRD. Im— CORNER • EIEVATKw �. _U apTRECORD • S[i. ,RI. ROD WINCAP LD7TB00 •CDLI�MITm PACE 1 OF 1 RECEIVED -�G6D , VY 7 G MAY 1. 8 2Q18 STATE OF FLORIDA DEPARTMENT OF HEALTH Permittin De art t ONSITE SEWAGE TREATMENT AND DISR,Q. e CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Standard Pacific of Florida GP, Inc AGENT: The Milcor Group, Inc. PROPERTY ADDRESS: 3010 NW Radcliffe Palm City, FL 34990 LOT: 4 BLOCK: APPLICATION #:APj291313 PERMIT # : 56-S F-1764096 DOCUMENT # : FI 1186142 DATE PAID:05/18/2017 FEE PAID:400.00 RECEIPT #:56-PID-3242910 SUBDIVISION: Riverbend ID# : 4425-703-0009-000-8 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION 101] TANK SIZE [11 800.00 [02] TANK MATERIAL [03] OUTLET DEVICE [041 MULTI -CHAMBERED [ Y N ] [051 OUTLET FILTER [061 LEGEND 1. 28-015-AA2C3 [071 WATERTIGHT (081 LEVEL [091 DEPTH TO LID DRAINFIELD INSTALLATION [101 AREA [1] 576 [21 [11) DISTRIBUTION BOX [12] NUMBER OF DRAINLINES 1131 DRAINLINE SEPARATION [141 DRAINLINE SLOPE [151 DEPTH OF COVER _ [21 483.00 Concrete 2. 70-143-54SC4 SQFT [ ] HEADER X [ ] 1. 3.00 2. [ ] [ l [16] ELEVATION [ ABOVE / BELOW ]BM 6.00 117] SYSTEM LOCATION [181 DOSING PUMPS [19] AGGREGATE SIZE [201 AGGREGATE EXCESSIVE FINES [21] AGGREGATE DEPTH 1.00 SETBACKS [271 SURFACE WATER 80 FT [281 DITCHES FT [29] PRIVATE WELLS FT [30] PUBLIC WELLS FT [311 IRRIGATION WELLS FT [321 POTABLE WATER 5 FT [331 BUILDING FOUNDATIONS 5 FT [341 PROPERTY LINES 6 FT [35] OTHER FT FILLED / MOUND SYSTEM [361 DRAINFIELD COVER [371 SHOULDERS [381 SLOPES [391 STABILIZATION 05/17/2018 ADDITIONAL INFORMATION [401 UNOBSTRUCTED AREA [41] STORMWATER RUNOFF [421 ALARMS [431 MAINTENANCE AGREEMENT [441 BUILDING AREA [45] LOCATION CONFORMS WITH SITE PLAN [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [47] CONTRACTOR (Brian Davis Septic) [ ] [221 FILL AMOUNT [ ] [48] OTHER Drip Irrigation - Netafim [ ] [231 FILL TEXTURE [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [49] TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED 6 FILLED Comments: Comments are on page 2. / / Lucie CHD DATE: 03/09/2018 CONSTRUCTION I APPROVED DISAPPROVED ] ' Envir3pmental Specialist I DI May (Florida Department of Health FINAL SYSTEM [ APPROVED / DISAPPROVED ]: cam, St. Lucie CHD DATE: 05/17/2018 Environmental Specialist II � J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Page 2 of 3 Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1291313 EID1764096 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment -a.. APPLICATION #:AP1291313 PERMIT #:56-SF-1764096 DOCUMENT # : F11186142 DATE PAID:05/18/2017 FEE PAID:400•00 RECEIPT #:56-PID-3242910 The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 460 gpd. New ST, DT and Pretreatment tank installed. The same model tank 70-143-54S-C4 (483 gal) was used for the Pretreatment tank and DT. Drainfield installed with 3 supply lines and 3 return lines each 48' with emitters every foot for a total of 288 emitters. 2 sq ft. per emitter--576 sq ft of DF. Sta-Right 1/2 HP pump installed in DT. System ok to cover, contractor notified onsite. Final required for mound system, alarm check and final site grading. ME contract needed prior to final approval. Final system approved. Contractor, builder, and building department emailed final approval. DR 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1291313 EID1764096