HomeMy WebLinkAboutKSM SOIL COMPACTION REPORTHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL 32771 9�:�t�iIY�EA CONTRACTOR: JOB LOCATION IV Ci 1 Ar ENGINEERING Z% L-J AVL AND TESTING SOIL COMPACTION REPORT ASTM-D-1557- and -ASTM-D-6938 September 27, 2021 QNI31I1Y.11 Wynne Development 3 Quintana Roo Lane Port St. Lucie, Florida Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone:772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB #: 217403-1d/MH/jam NUC # 630 Nuc Model: MC-IDR-P Nuc Serial #: 30630 ITEM TESTED: Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE-(P.C.F) COMPACTION 1 N.W. 0" - 12" 50 107.9 108.7 99.3% 2 N.E. 108.3 99.6% 3 Center 108.1 99.4% 4 S.W. 108.0 99.4% 5 S.E. 108.1 99.4% Soil Description: 110.0 1 I T I 1 I I 1 Brawn -Sand W I E109.0—.._.._..._.._.._..._.._.._.._.._.. I I I I I I I In Place Moisture: I I I I I I i I 10.3% H 108-0 �.. �.._.I._.. .._I. _.(_.. .._�.._.. Proctor Optimum Moisture: T I I I I I �.._.I_..�.. I I 0 12.0% 107.0 4—..-4.._.I._..4-.. 1._.. P I I I I I I I Proctor Max. Dry Density: P.C.F. 106.0 t ..�.._.r_.. ..�.._.I_..t.._r._.. 108.7 C @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets \\\t\nnlrr/I/ Minimum Requirement ,,\\\ %F_ KEG \\ vv.......... • �� for Staked Foundation �,•'\\cENSF'-,�Q Respectfully Submitted_, Dlglla�ly.' No.68366 _ * *— signe_c6b-y : Ar Ju1ieA1eP STATE OF ` Date: � .......• aG\ 2021.09NI10NnlAY. fo\\\\ rrrn\ I I I I I I F 105.0 .. i _..�.._I.._.i_..T 104.0 .. �.._.�_..� .. �.._.�_.. D R 103.0—.-�.._.�_..�.. I.._.�_..�.._�._.., Y 7 8 9 10 11 12 13 14 15 Moisture - % of Dry Weight Disclaimer: Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. 11:54:29 -04'00' Julie E. Keller, P.E. President PE # 68366 9/28/2021 Email to: dotty@wynnebc.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing GeotechnicaI Engineering -Construction Materials Testing - Specla I Inspections - Clvll and Structural Consulting Proudly serving Florida since 1990 Certified Women Owned Business - WBE