Loading...
HomeMy WebLinkAboutWATER HEATERPRINTED IN U.S.A. 12/20 WP FORM NO. PROG RH N COMBO Rev. 3 INTEGRAT ED HOME COMFORTINTEGRATED HOME COMFORT Professional Classic® Atmospheric gas water heaters are engineered for more hot water at a low operating cost Professional Classic Atmospheric 29, 30, 40 and 50-Gallon Capacities Up to 40,000 BTU/h Natural and LP Gas Water INTEGRATED HOME COMFORT Residential Gas Professional Classic Atmospheric Water Heaters See specifications chart on back. Efficiency • .58 - .66 UEF • More hot water at a low operating cost Performance • FHR: 51 - 87 gallons • Recovery: 30.3 to 40.4 GPH at a 90° F rise, depending on model Guardian System™ & Sensor • Exclusive air/fuel shut-off device • Maintenance free – no filter to clean • Protective control system that disables the heater in the presence of flammable vapor accumulation Low Emissions • Eco-friendly burner, low NOx design • Meets 40 ng/J NOx requirements Longer Life • Premium grade anode rod provides long-lasting tank protection Altitude Certification • All models certified up to 5,999 feet above sea level, some certified up to 10,000 feet. Consult factory for specifications Plus… • Easy to light – no matches required • EverKleen® patented system fights sediment build-up • Exclusive Rheemglas® tank lining resists corrosion and prolongs tank life • Enhanced flow brass drain valve • Temperature and pressure relief valve included • Factory installed temperature and pressure relief valve on select models • Low lead compliant • Standard replacement parts Warranty • 6-Year limited tank and parts warranty* • With ProtectionPlus® the 6-year limited tank warranty becomes 10-year * See Residential Warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. † LEED Point = 1 Maintenance Free Flame Arrestor PlateCombustion Shut-off System NEW! Installed Top T&P Valve on Select Models PRINTED IN U.S.A. 12/20 WP FORM NO. PROG RH N COMBO Rev. 3 INTEGRAT ED HOME COMFORTINTEGRATED HOME COMFORT In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.rheem.com Water INTEGRATED HOME COMFORT Residential Gas Professional Classic Atmospheric Water Heaters 2 Professional Classic® Atmospheric Specifications †LEED Point = 1 E G BA C F HHOTWATERCONNECTION HCOLDWATERCONNECTION D 1/2" 3/4" N.P.T.RELIEF VALVEOPENING FLUE ANODE ROD Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements. DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES)ENERGY INFO. T Y P E NOMINAL GALLON CAPACITY RATED GALLON CAPACITY MODEL NUMBER GAS INPUT IN THOUS. BTU/H RECOVERY IN G.P.H. 90° F RISE FIRST HOUR RATING (GALLONS) HEIGHT TO VENT A TANK HEIGHT B DIAM. C HT. TO GAS CONN. D VENT SIZE E WATER CONN. CENTER F HT. TO SIDE T&P VALVE G WATER CONN. SIZE H SHIP WT. (LBS) UNIFORM ENERGY FACTOR (UEF)NAT.LP NAT.LP NAT.LP Tall 29 28 PROG29-32N RH63 32 –32.3 –63 –59-3/4 56-7/8 16-1/2 14-1/4 3 or 4 8 50-3/4 3/4 110 0.60 Tall 29 28 PROG29-30P RH63 –30 –30.3 –63 59-3/4 56-7/8 16-1/2 14-1/4 3 or 4 8 50-3/4 3/4 110 0.60 Tall 40 38 PROG40-36N RH62†36 –36.4 –64 –61-1/2 58-1/2 19 14-1/4 3 or 4 8 52-1/4 3/4 127 0.58 Tall 40 38 PROG40-38N RH62†38 –38.4 –64 –61-1/2 58-1/2 19 14-1/4 3 or 4 8 52-1/4 3/4 127 0.58 Tall 40 38 PROG40-40N RH62†40 –40.4 –84 –63-1/4 60 19-1/2 14 3 or 4 8 53-1/2 3/4 135 0.66 Tall 40 38 PROG40-36P RH62†–36 –36.3 –84 63-1/4 60 19-1/2 14 3 or 4 8 53-1/2 3/4 135 0.66 Tall 40 38 PROG40-32P RH62†–32 –32.3 –67 61-1/2 58-1/2 18-1/2 14-1/4 3 or 4 8 52-1/4 3/4 125 0.59 Tall 50 48 PROG50-40N RH62†40 –40.4 –76 –62-1/2 59-1/4 21-1/2 14-1/2 3 or 4 8 52-1/2 3/4 165 0.65 Tall 50 48 PROG50-36P RH62†–36 –36.4 –76 62-1/2 59-1/4 21-1/2 14-1/2 3 or 4 8 52-1/2 3/4 165 0.65 Tall 50 48 PROG50-38N RH60†38 –38.4 –85 –61-1/4 58-3/8 20-1/2 14-1/4 3 or 4 8 51-3/8 3/4 150 0.64 Tall 50 48 PROG50-36P RH60†–36 –36.4 –85 61-1/4 58-3/8 20-1/2 14-1/4 3 or 4 8 51-3/8 3/4 150 0.64 Short 30 29 PROG30S-30N RH63 30 –30.3 –51 –49-7/8 47 19-3/4 14-1/4 3 or 4 8 40-3/8 3/4 112 0.60 Short 40 38 PROG40S-40N RH62†40 –40.4 –66 –53-7/8 50-1/2 23 14-1/2 3 8 44 3/4 135 0.58 Short 40 38 PROG40S-36P RH62†–36 –36.4 –66 53-7/8 50-1/2 23 14-1/2 3 8 44 3/4 135 0.58 Short 40 39 PROG40S-38N RH62†38 –38.4 –65 –53-1/4 50-1/4 21-3/8 14-1/4 3 or 4 8 44 3/4 125 0.58 Short 40 39 PROG40S-35P RH62†–35 –35.4 –65 53-1/4 50-1/4 21-3/8 14-1/4 3 or 4 8 44 3/4 125 0.58 Short 40 38 PROG40S-34N RH62 34 –34.3 –64 –52-3/8 49-1/8 21 14 3 or 4 8 42-3/4 3/4 120 0.59 Short 40 38 PROG40S-31P RH62 –31 –31.3 –65 52-3/8 49-1/8 21 14 3 or 4 8 42-3/4 3/4 120 0.59 Short 50 48 PROG50S-40N RH61†40 –40.4 –87 –54-1/4 51-1/8 23-3/4 14-1/4 3 or 4 8 44 3/4 186 0.63 Short 50 48 PROG50S-36P RH61†–36 –36.4 –87 54-1/4 51-1/8 23-3/4 14-1/4 3 or 4 8 44 3/4 186 0.63 Models with Installed Top T&P Valve Tall 40 38 PROG40-38N RH62TT 38 –38.4 –64 –61-1/2 58-1/2 19 14-1/4 3 or 4 8 –3/4 127 0.58 Tall 40 38 PROG40-40N RH62TT 40 –40.4 –64 –63-1/4 60 19-1/2 14 3 or 4 8 –3/4 135 0.66 Tall 50 48 PROG50-40N RH62TT 40 –40.4 –85 –62-1/2 59-1/4 21-1/2 14-1/2 3 or 4 8 –3/4 165 0.65 Tall 50 48 PROG50-38N RH60TT 38 –38.4 –84 –61-1/4 58-3/8 20-1/2 14-1/4 3 or 4 8 –3/4 150 0.64 E BA C F HHOTWATERCONNECTION HCOLDWATERCONNECTION D 1/2" FLUE ANODE ROD TOP T&P1-1/2" ABOVETOP PAN TO CENTER OF OPENING INSTALLED T&P VALVE Top T&P models