Loading...
HomeMy WebLinkAboutGENERATOR GENERAC° GUARDIAN° SERIES 2��22�24 kW Residential Standby Generators Air-Cooled Gas Engine r INCLUDES: Standby Power Rating 0007038-1,0007039-1,G007038-3,G007039-3(Alumnum-Bisque)-20 kW 60 Hz • True Power" Electrical Technology G007.042-2F(3M7043=2,G007042-3`,`GO07043-3(Aluminum-Bisque)-22 M 6o:QZ 0007209-0,G007210-0(Aluminum-Bisque)-24 kW 60 Hz • Two-line multilingual digital LCD Evolution'" controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor • Standard Wtt-Fte connectivity • System status&maintenance interval LED indicators • Sound attenuated enclosure • FTe)able fuel line connector • Natural gas or LP gas operation GENERAC' 1 �r • 5 Year limited warranty 1 • listed and labeled by the Southwest Research Institute allowing installation as close as 18 in(457 mm)to a structure.` 'Must be located away from doors,windows,and fresh air intakes and in accordance with local codes. T I■ U hUps:llamts.wi.org/�t`tbrary/DirectoiyOfL/�stedProduc/s/ E 1 r us�r CLISTERUS ("` Vill /��J U' L°*� ConsUu wdndustryl973_DoC 204_13204-01-01_Rev9.pol ° Note:CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This erac's success in providing the most reliable generators possible. Generac's G- state-of-the-art power maximizing regulation system is standard on all Generac mod- Face engine lineup offers added peace of mind and reliability lot when it's needed els.it provides optimized FAST RESPONSE to changing load conditions and MA)Q- the most The G-Force series engines are purpose built and designed to handle the MUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge rigors of edended run Umes in high temperatures and extreme operating conditions. loads to the engine.Digital voltage regulation at±1%. O TRUE POWER"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit,from the engine to the small- allows confident operation of sensitive electronic equipment and micro-chip based est electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS.One reason for this confidence is that the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls tot total system compatibility. O MOBILE LINK' CONNECTIVITY:FREE with select Guardian Series Home standby O PWRVIEW'" TRANSFER SWITCH: The Generac PWRview Automatic Transfer generators,Mobile Link WI-Fl allows users to monitor generator status from any- Switch Integrates the PWRview energy monitor to provide real-time energy con- where in the world using a smadphone,tablet,or PC,Easily access Information such sumpt(on data that can help lower a home's electricity bill. Using a convenient as the current operating status and maintenance alerts. Users can connect an mobile app,homeowners can access energy usage and alert information while under account to an authorized service dealer lot last,friendly,and proactive service,With utility power or generator power.The PWRview energy monitor is a simple to use and Mobile Link,users are taken care of before the next power outage, low coal toot which helps save money over the life of the generator.included with model G007210-0. " GENERAC ,y�•+y t""�`. GENERAC' `PROMISE ® '®� . `"` PW R 'J �02CPIERAC® 20/22/24 kW Features and Benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency,Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance,and longer engine ' life.Now featuring up to a 2 year/200 hour oil change Interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch(if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Integrated load management technology Capability to manage additional loads for efficient power management. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. PWRview Transfer Switch (if applicable) • PWRview energy monitor Energy usage at-a-glance. • Ability to view real-time energy consumption data Better understand the home's energy profile. • PWRview mobile app Access daily energy intelligence and insights. Evolution— Controls • AUfO/MANUAUOFF illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency, GENERAC® 20/22/24 kW Features and Benefits Unit _ • SAE Nt allla proleCM enclosure Sound allonualed onclosuros ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h),Hinged key locking root panel for security.Lilt-oul front for easy access to all routine maintenance Items.Electrostatically applied textured epoxy paint for added durability. • BOoed tx+VA grade mutflet Quiet,critical grade mulller Is mounted Inside the unit to prevent Injuries, • snW1,comam amacinIO Makes loran easy,eye appealing Installation,as close as 18 In(457 mm)away from a structure. lnstaltation System • 14 in(SS.6 n)IlMVe Arel line connector Listed ANSI Z21.15/CSA 6,27 outdoor appliance connector for the required connection 10 the gas supply piping. • "wal s&Wit trap Meets IFGC and NFPA 54 Installation requirements. Connecl3vilty(Wi-Fi equipped models only) • A Or to view gm*raor status Monitor generator with a smartphone,tablet,or computer at any time via the Mobile Link application for complete peace of mind. • Ai Oy to view geneiralor Exemse/Run and Total Hours Review the generators complete protection profile for exercise hours and total hours. • ,4R*to vier generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Hor4 report vauh previous month's activity Detailed monthly reports provide historical generator information. • r ID vim generator battery information Built in battery diagnostics displaying current state of the battery. • Weate Nornabon Provides detailed local ambient weather conditions for generator location. ''�F GENERAC' 20/22/24 kW Specifications Generator Model G007038-1 0007042-2 G007038-3 G007042-3 G007209-0 G007039-1 G007043-2 GDO7039-3 G007043-3 G007210-0 (20 kW) (22 kW) (20 kW) (22 kW) (24 kW) Rated maximum continuous power capacity(LP) 20,000 Watts' 42;000 Walls' 20,000 Watts` 22,000 Watts' 24,000 Watts' Rated maximum continuous power capacity(NG) 18,000 Watts' 19,500 Watts' 18,000 Watts' 19,500 Watts' 21.000 Watts' Rated voltage 240 Rated maximum continuous load current—240 volts(LP/NG) 83.3/75.0 917/81.3 83.3/75.0 91.7/81.3 100/87.5 ' Total Harmonic Distortion Less than 5% Main line circuit breaker 90 amp 100 amp 90 amp 100 amp 100 amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included] 12 Volts,Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum Unit weight(lb/kg) 448/203 466/211 436/198 445/202 455/206 Dimensions(L x.W x H)in%cm 46 x 25 x 29/121.9 x 63.5 x 73.7 Sound output in dB(A)at 23 it(7 m)with generator operating at normal load'" 67 67 67 67 67 Sound output in dB(A)at 23 R(7 m)with generator in Quiet-Test"low-speed exercise mode" 55 57 55 57 57 Exercise duration 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/magneto Governor system Electronic Compression ratio 9,51 Starter 12 VDC Oil capacity including filter Approx.1.9 qt/1.8 L Operating rpm 3.600 Fuel consumption Natural gas ft3/hr(0/hr) 1/2 Load 204(5.78) 228(6.46) 164(4.64) 203(5.75) Full Load 301(8.52) 327(9.26) 287(8.13) 306(8.66) Liquid propane 113/hr(gal/hr)[Uhr] 1/2 Load 87(2.37)[8.99] 92(2.53)[9.57] 86(2.36)[8.95] 92(2,53)[9.57] Full Load 130(3.56)[13.481 142(3.90)[14.771 136(3.74)114.151 142(3.90)[14.77] Note:Fuel pipe must be shed for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas.For BTU content,multiply ft3/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG). Controls . Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons AUTO Automatic start on utility failure.Weekly,BI-weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.II utility fails,transfer to load takes place. OFF Stops unit.Power is removed.Control and charger s811 operate. Ready to Run/Mainlenance messages Standard Engine run hours indication standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable(brownout setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard RuWAlarm/Mainferlance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter lock-out Starter cannot re-engage until 5 sec after engine has slopped. Smart Battery Charger Standard Charger Faulf/Missing AC waming Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation witfi3Over=and Under Voltage Protection. Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard 'Overcrank/Overspeed(@'72 Hz)/rpm Sense Loss Shutdown, Standard High Engine Temperature Shutdown Standard ,Intemal FauitAncorredWidng protiolon - Standard Common external fault capability Standard 'Field upgradable firrrnvare _ Standard "Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on Installation parameters.Rating definitions-Standby.Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings In accordance with BS5514,IS03046 and DIN6271).'Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megaloule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 0(304.8 m)above sea level;and also will decrease approximately 1%for each 10°F(6°C)above 60°F(16°C). GENERAC" 20/22/24 kW Switch Options Service Rated Automatic Transfer Switch Features Model G007039-1,0007039-3(20 kW) • Intelligently manages up to four air conditioner loads with no additional hardware. 13007043.2,G007043-3(22 kW) No,of poles 2 • Up to eight additional large(240 VAC)loads can be managed when used In conjunction Current rating(amps) 200 with Smart Management Modules(SMMs). Voltage rating(VAC) 1201240,10 • Electrically operated,mechanically-held contacts for fast,clean conneclions. Utility voltage monitor(fixed)' -Pick-up 80% • Rated for all classes of load,100%equipment rated,both inductive and resistive. -Dropout 65% • 2-pole,250 VAC contactors. Return to Utility' Approx.13 sec • Service equipment rated,dual coil design, Exercises hl-weekly for 5 minutes' Standard E o UL listed Standard • Rated for both aluminum and copper conductors. Enclosure slosure type NEMANL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000 • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Lug range 250 MCM-#6 *Function of Evolution controller Dimensions Exercise can be set to weekly,bi-weekly,or monthly w, 200 Amps 120/240,1 o Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 26.8 30.1 10.5 13.5 6.9 cm 67.95 1 76,43 26.67 34.18 17.5 ez "' fte Ranges CorAudnr Lug Neutral Lug Ground Lug 250 MCM-T6 350MCM-#6 210-#14 oFrn, 1--w2--i PWRview Automatic Transfer Switch Features Model 0007210-0(24 kW) • krtegrded PWRview monitor provides real-time energy usage data through PWRview app. No.of poles 2 Current rating(amps). �M • kailigelady manages up to four air conditioner loads with no additional hardware. Voltage rating(VAC) 120/240.10 • Up to eight additional large(240 VAC)loads can be managed when used in conjunction Utility voltage monitor(fixed)* with Smart Management Modules(SMMs). -Pick-up 80% -Dropout _ 65% • 6edrically operated,mechanically-held contacts for fast,clean connections. -Drum to Utility' Approx.13 sec • Rated for all classes of load,100%equipment rated,both inductive and resistive. Exercises bi-weekly for 5 minutes" Standard • 2-pole,250 VAC contactors. ETL or UL listed Standard • Service equipment rated,dual coil design. Eddliis r e NEMA 3R- ZirouiWreakenprotWed 22,000 • Rated for both aluminum and copper conductors. Lug range 250 MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. 'Function of Evolution controller • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Exercise can be set to weekly,bl-weekly,or monthly • Heavy duty Generac Contactor is an ETL recognized device. w, Dimensions 200 Arw 12W2A ,to Open Tra-altion Service Rated Hero Widtb ,n n, H1 H2 W1 W2 in 26-8 30.1 10.5 13,5 6,9 an 67.95 76A3 26.67 34.18 17,5 Wire Ranges Conductor Lug NerArai Luq Ground Lug 250 MCM-#6 350 MCM-#6 GENERAC® 20/22/24 M Available Accessories Model# Product Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact°). G007101-0 Battery Pad Warmer Pad warmer rests under the battery.Recommended for use if temperature regularly falls below 0°F(-18°C).(Not nec- essary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if temperature regularly falls below 0°F(-18°C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be Contact Kit needed.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air-cooled generators.This offers a sleek,contoured (Standard on 22/24 kW) appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006485-0 Scheduled Maintenance Kit 'Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator(oil not included). G007005-0 Wi-F LP Tank Fuel Level The Wi-F enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the Monitor LP tankls fuel level is an important step in verifying the generator is ready to run during an unexpected power failure.Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amp) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded.In many cases,using SMM's can reduce (100 amp) :the overall size and cost of the system. G00716M-413 LTE Mobile Link'Cellular The Mobile Linkfamily of Cellular Accessories allow users to monitor generator status from anywhere in the world,using G007170-0-Wi-FU Accessories a smart phone,tablet,or PC.Easily access information such as the current operating status and maintenance alerts.Us- Ethernet ers can connect an account with an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,contoured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.lot contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs Model UPC .o ice,637.6 mm f.f 12,g8 mm 125,m, > G007038-1 696471074185 G007038-3 696471074185 G007039-1 696471074192 G007039-3 696471074192 G007042-2 696471074208 727,2mm G007042-3 696471074208 G007043-2 696471074215 G007043-3 696471074215 p 0 0 G007209-0 696471071511 G007210-0 696471078220 „ 1232 mm. ie.61n, LEFT BIDE VIEW FRONT VIEW Dimension shown are approximate.Sao Installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES, G E N E R AC* Generac Power Systems,Inc. • S45 W29290 I-IWY.59,Waukesha,WI 53189 • generac.com 02020 Generac Power Systems,Inc.All rights reserved.All spoclllcallons are subject to change without notice.Part No.A0000937814 Rev.B 07/30/2020