Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
STOREFRONT ENTRANCE DOOR DETAILS
TABLE 1:INSTRUCTIONS:1.DETERMINE THE BUILDING'S REQUIRED DESIGN PRESSURE USING THE ASCE 7 STANDARD. THE DOOR'SDESIGN PRESSURE MUST MEET OR EXCEED THIS VALUE.2.DETERMINE THE ANCHOR GROUP FROM TABLE 1, THIS SHEET.3.VERIFY THAT THE CHOSEN THRESHOLD MEETS THE REQUIRED POSITIVE (+) DESIGN PRESSURE FROMTABLE 14, SHEET 13.4.DETERMINE THE MAXIMUM DESIGN PRESSURE DUE TO GLAZING, FROM SHEET 2 (SINGLE DOOR) ORSHEET 3 (DOUBLE DOOR).5.IF YOUR ASSEMBLY INCLUDES A VERTICAL MULLION AND STOREFRONT WINDOW: A) DETERMINE THE VERTICAL MULLION TYPE & DESIGN PRESSURE FROM SHEETS 4-7. B) DETERMINE THE VERTICAL MULLION DESIGN PRESSURE DUE TO ANCHORAGE FROM SHEET 9 (1/4" SHIM) OR SHEET 10 (1/2" SHIM). C) DETERMINE THE DESIGN PRESSURE OF THE STOREFRONT WINDOW FROM IT'S OWN APPROVAL.6.IF YOUR ASSEMBLY IS OR CONTAINS A DOUBLE DOOR, DETERMINE THE QUANTITY OF ANCHORSREQUIRED ABOVE THE MEETING STILES (HEAD) OR BELOW THE MEETING STILES (SILL) FROM SHEET 8.7.DETERMINE THE MAXIMUM JAMB ANCHOR SPACING FROM SHEET 11. VALUES HAVE BEEN CALCULATEDUSING THE DOOR'S MAXIMUM DESIGN PRESSURE.8.DETERMINE THE MAXIMUM DESIGN PRESSURE DUE TO HARDWARE FROM SHEETS 18 & 19.9.THE LOWEST DESIGN PRESSURE FROM 3, 4, 5 & 8 ABOVE, SHALL BE USED FOR THE ENTIRE ASSEMBLY.RATED FOR LARGE & SMALLMISSILE IMPACT RESISTANCEIMPACT RATINGA. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER GENERAL NOTES:1.THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FBC, INCLUDING THE HIGHVELOCITY HURRICANE ZONE (HVHZ).2.SHUTTERS ARE NOT REQUIRED PER FBC REQUIREMENTS, WHEN USED IN WIND-BORNE DEBRIS REGIONS.3.GLAZING TYPE: SEE GLAZING DETAILS ON SHEET 15.4.DESIGN PRESSURES: A) NEGATIVE DESIGN LOADS BASED ON STRUCTURAL & CYCLE TESTING AND GLASS PER ASTM E1300 B) POSITIVE DESIGN LOADS BASED ON WATER INFILTRATION, STRUCTURAL & CYCLE TESTING AND GLASS PER ASTM E1300 C) DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN, ASD.5.THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS CORRESPONDING TO THE REQUIREDDESIGN PRESSURE. THE 33-1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOADDURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD.6.INSTALLATION SCREWS & FRAME CORNERS TO BE SEALED WITH NARROW JOINT SEALANT.7.DOOR SIZES MUST BE VERIFIED FOR COMPLIANCE WITH EGRESS REQUIREMENTS OF THE FBC, AS APPLICABLE.8.DISSIMILAR MATERIALS THAT COME INTO CONTACT, INCLUDING PRODUCT FRAMING, ANCHORAGE AND OPENINGSUBSTRATES, SHALL BE COATED OR PROTECTED TO PREVENT CORROSIVE REACTIONS AS REQUIRED BY THE FLORIDABUILDING CODE.9.REFERENCES: ELCO ULTRACON & CRETEFLEX NOA'S, ITW TAPCON NOA; TEST REPORTS FTL-7137, 8717, 8842, 17-7538 &17-7007.10.THIS DOOR SYSTEM MAY BE USED WITH ANY COMPATIBLE CGI-COMMERCIAL STOREFRONT WINDOW SYSTEM. WINDOWSYSTEM MUST HAVE ITS OWN APPROVAL.* MIN. OF 3 THREADS BEYONDTHE METAL SUBSTRATE.METAL SUBSTRATE TO MEETMIN. STRENGTH ANDTHICKNESS REQUIREMENTSPER CURRENT FLORIDABUILDING CODE AND TO BEREVIEWED BY THE AUTHORITYHAVING JURISDICTION.FOR STEEL STUDS,MIN. FU=45 KSI &MIN. FY=33 KSI."UNGROUTED CMU" VALUESMAY BE USED FOR GROUTEDCMU APPLICATIONS.ALL ANCHOR HEAD TYPES AREALLOWED.ANCHOR NOTES:1.FOR CONCRETE/CMU SUBSTRATE APPLICATIONS IN MIAMI-DADE COUNTY, USE ONLY MIAMI-DADE COUNTY APPROVEDELCO ANCHORS. SEE TABLE 1 ON THIS SHEET FOR EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS.2.FOR SUBSTRATE APPLICATIONS SEE TABLE 1 ON THIS SHEET.3.WOOD BUCKS DEPICTED AS 1X ARE LESS THAN 1-1/2" THICK. PROPERLY SECURED, 1X WOOD BUCKS ARE OPTIONAL IFUNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE OR CMU. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK ORGREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE.BUCK DESIGN AND INSTAL- LATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD & TO BEREVIEWED BY THE BUILDING OFFICIAL.4.SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMSCAPABLE OF TRANSFERRING APPLIED LOADS. WOOD BUCKS, BY OTHERS, MUST BE SUFFICIENTLY ANCHORED TO RESISTLOADS IMPOSED ON THEM BY THE WINDOW.5.METAL SUBSTRATE TO MEET MIN. STRENGTH AND THICKNESS REQUIREMENTS PER THE FBC AND TO BE REVIEWED BYTHE AUTHORITY HAVING JURISDICTION.6.IF SILL IS TIGHT TO SUBSTRATE, GROUT OR OTHER MATERIAL IS NOT REQUIRED. IF USED, NON-SHRINK, NON-METALLICGROUT, MAX. 1/4" THICK & 3400 PSI MIN., (DONE BY OTHERS) MUST FULLY SUPPORT THE ENTIRE LENGTH OF THE SILLTHAT IS NOT TIGHT TO THE SUBSTRATE, AND TRANSFER SHEAR LOAD TO SUBSTRATE. IF SUBSTRATE IS WOOD, 30# FELTPAPER OR MASTIC IS REQUIRED BETWEEN THE GROUT AND WOOD SUBSTRATE, OR AS APPROVED BY THE AUTHORITYHAVING JURISDICTION.GENERAL NOTES: SE-3550 IMPACT-RESISTANT, OUTSWING STOREFRONT ENTRANCE DOORNTS1 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKIGENERAL NOTESJAMB ANCHOR SPACING, TABLES 12 & 13.........................HORIZ. SECTIONS..................................................................VERT. SECTIONS....................................................................TRANSOM SECTIONS.............................................................GLAZING & IG SPACER DETAILS..........................................EXTRUSION PROFILES..........................................................PARTS LIST, TABLE 10...........................................................CORNER DETAILS..................................................................HARDWARE.............................................................................111213141516161718-19CONTENTS:FLORIDA PRODUCT APPROVAL # 25573GENERAL NOTES, INSTRUCTIONS......................................ANCHOR TYPES, TABLE 1.....................................................GLASS DP, TABLES 2 & 3......................................................ELEVATIONS, SINGLE DOOR................................................ELEVATIONS, DOUBLE DOOR...............................................ELEVATIONS, DOOR WITH STOREFRONT WINDOW..........VERTICAL MULLION DP, TABLES 4-7...................................HEAD/SILL CLUSTER QUANTITY, TABLES 8 & 9.................MULLION ANCHOR CLUSTER DP - 1/4" SHIM, TABLE 10...MULLION ANCHOR CLUSTER DP - 1/2" SHIM, TABLE 11... 10112-3234-74-789JR09/15/20ADDED PARTS #48 & #49, ULTRACON+ 51-1/2" MAX.DOOR FRAME WIDTH1 INSTALLATION ANCHOR@ 3-7/8" MAX. THRU ANGLE BRACKETSEE MAX. JAMBANCHOR O.C. SPACINGON TABLES 12 & 13120" MAX.DOORFRAME/OVERALLHEIGHT6" MAX. O.C.ANCHOR REQUIRED@ 3-7/8" MAX.ANCHOR REQUIRED@ 9-7/8" MAX.17-7/8"MAX .O.C.6" MAX.ANCHOR REQUIRED@ 3-7/8" MAX.ANCHOR REQUIRED@ 9-7/8" MAX.17-7/8"MAX .O.C.6" MAX.51-1/2" MAX.DOOR FRAME WIDTHSEE MAX. JAMBANCHOR O.C. SPACINGON TABLES 12 & 13DOOR FRAME HEIGHTSOVER 97-3/4" OR DOORFRAME WIDTHS OVER39-1/2" REQUIRE SPECIALHARDWARE, SEESHEETS 18, 19, & 20.TYP. ELEVATION OF SINGLEDOOR WITHOUT TRANSOMTYP. ELEVATION OF SINGLEDOOR WITH TRANSOMSEE SHEET 17 FORANGLE BRACKET TOJAMB ATTACHMENT105-3/16"MAX. DLO39-13/16"MAX. DLODETAIL LETTERA12A12C12C12D13F14E13E13G14TABLE 2:120" MAX.OVERALLHEIGHTH14DOORFRAMEHEIGHTREINFORCEMENT #11REQUIRED IF USINGGLASS TYPES C OR FSEE SHEET 17 FORANGLE BRACKET TOJAMB ATTACHMENT42" MAX.TRANSOMHEIGHTX#SHEET NUMBER1 INSTALLATION ANCHOR@ 3-7/8" MAX. THRU ANGLE BRACKETNTS2 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKIELEVATIONS FOR GLAZING DP, AEGRESS FORMULAS:SINGLE DOOR FRAME WIDTH - 6-3/8" = EGRESS WIDTHFRAME HEIGHT - 2-3/8" - THRESHOLD HEIGHT = EGRESS HEIGHTDLO (DAYLIGHT OPENING) FORMULAS:SINGLE DOOR FRAME WIDTH - 9-15/16" = DLO WIDTHDOOR FRAME HEIGHT - 14-13/16" = DLO HEIGHTTRANSOM WIDTH - 6" = DLO WIDTHTRANSOM HEIGHT - 3-3/4" = DLO HEIGHTENTRY DOOR NOTES:1. SEE SHEET 15 FOR GLAZING TYPES AND DESCRIPTIONS.FOR SIZES NOT SHOWN, ROUND UP TO THENEXT AVAILABLE WIDTH OR HEIGHTDIMENSION SHOWN ON THE TABLE.ADDED PAGE 20 TO SPECIAL HARDWARE NOTEHC04/13/21A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER ANCHOR REQUIRED@ 3-7/8" MAX.ANCHOR REQUIRED@ 9-7/8" MAX.6" MAX.TYP. ELEVATION OF DOUBLEDOOR WITHOUT TRANSOMTYP. ELEVATION OF DOUBLEDOOR WITH TRANSOM99-1/2" MAX. DOOR FRAME WIDTH17-7/8"MAX .O.C.SEE MAX. JAMBANCHOR O.C. SPACINGON TABLES 12 & 13105-3/16"MAX. DLO36-13/16"MAX. DLOA12B12C12D13E13120" MAX.DOORFRAME/OVERALLHEIGHTTABLE 3:6" MAX.17-7/8"MAX .O.C.6" MAX. O.C.ANCHOR REQUIRED@ 3-7/8" MAX.ANCHOR REQUIRED@ 9-7/8" MAX.75-1/2" MAX. DOOR FRAME WIDTHSEE MAX. JAMBANCHOR O.C. SPACINGON TABLES 12 & 13H14A12C12B12F14E13G14120" MAX.OVERALLHEIGHT97-3/4"MAX.DOORFRAMEHEIGHTSEE SHEET 8 FOR ANCHORQUANTITY & O.C. SPACINGREINFORCEMENT #11REQUIRED IF USINGGLASS TYPES C OR FSEE SHEET 17 FORANGLE BRACKET TOJAMB ATTACHMENTSEE SHEET 17 FORANGLE BRACKET TOJAMB ATTACHMENTDOOR FRAME HEIGHTSOVER 97-3/4" OR DOORFRAME WIDTHS OVER75-1/2" REQUIRESPECIAL HARDWARE,SEE SHEETS 18, 19, & 20.42" MAX.TRANSOMHEIGHTDETAIL LETTERX#SHEET NUMBER1 INSTALLATION ANCHOR@ 3-7/8" MAX.THRU ANGLE BRACKET1 INSTALLATION ANCHOR@ 3-7/8" MAX. THRU ANGLE BRACKETNTS3 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKIEGRESS FORMULAS:DOUBLE DOOR FRAME WIDTH / 2 - 4" = EGRESS WIDTHFRAME HEIGHT - 2-3/8" - THRESHOLD HEIGHT = EGRESS HEIGHTDLO (DAYLIGHT OPENING) FORMULAS:DOUBLE DOOR FRAME WIDTH / 2 - 8-3/16" = DLO WIDTHDOOR FRAME HEIGHT - 14-13/16" = DLO HEIGHTTRANSOM WIDTH - 6" = DLO WIDTHTRANSOM HEIGHT - 3-3/4" = DLO HEIGHTNO TRANSOMS ALLOWED FOR DOORFRAME HEIGHTS OVER 97-3/4".SEE SHEET 8 FORANCHOR QUANTITY& O.C. SPACINGSEE SHEET 8 FOR ANCHORQUANTITY & O.C. SPACINGENTRY DOOR NOTES:1. SEE SHEET 15 FOR GLAZING TYPES AND DESCRIPTIONS.ELEVATIONS FOR GLAZING DP, BFOR SIZES NOT SHOWN, ROUND UP TO THENEXT AVAILABLE WIDTH OR HEIGHTDIMENSION SHOWN ON THE TABLE.ADDED PAGE 20 TO SPECIAL HARDWARE NOTEHC04/13/21A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER 51-1/2" MAX.DOOR FRAME WIDTH1 INSTALLATIONANCHOR@ 3-7/8" MAX.THRU ANGLEBRACKETSEE MAX. JAMBANCHOR O.C. SPACINGON TABLES 12 & 13ANCHORREQUIRED@ 3-7/8" MAX.ANCHOR REQUIRED@ 9-7/8" MAX.17-7/8"MAX. O.C.TYP. ELEVATION OF SINGLEDOOR WITHOUT TRANSOMA12D13E13ATTACHEDSTOREFRONTWINDOW,SEE SEPARATEAPPROVAL FORSPECIFICATIONSJ14120" MAX.DOORFRAME/OVERALLHEIGHTSEE TABLE 4,THIS SHEET FORREINFORCEMENTTYPE1/4" NUT & BOLT,24" FROM EACH ENDAND 24" MAX O.C.DOOR + WINDOW FRAME WIDTHTABLE 4:SEE SHEETS 9 & 10 FOR ANCHORPATTERN, QUANTITY & SPACINGSEE SHEET 17 FORANGLE BRACKET TOJAMB ATTACHMENT6" MAX.STOREFRONT WINDOW NOTES:1. SEE SEPARATE APPROVAL FOR STOREFRONT WINDOW SPECIFICATIONS.2. IF A SERIES OF STOREFRONT WINDOWS ARE USED, USE ONLY 1 WINDOW DIRECTLY ADJACENT TO THE DOOR IN DETERMINING THE DOOR + WINDOW FRAME WIDTH.3. IF STOREFRONT WINDOWS ARE USED ON BOTH SIDES OF A DOOR (EX. OXO), DETERMINE THE DOOR + WINDOW FRAME WIDTH USING THE WIDER WINDOW.4. THE LESSER DESIGN PRESSURE OF THE DOOR OR STOREFRONT WINDOW SHALL GOVERN THE DESIGN PRESSURE FOR THE ENTIRE ASSEMBLY.DETAIL LETTERX#SHEET NUMBERSEE SHEETS 9 & 10 FORANCHOR PATTERN,QUANTITY & SPACINGNTS4 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKIELEVATIONS FOR MULLION DP, ATYP. ELEVATION OFKNEEWALL INSTALLATIONJ141/4" NUT & BOLT,24" FROM EACH ENDAND 24" MAX O.C.SEE SHEETS 9 & 10 FOR ANCHORPATTERN, QUANTITY & SPACINGSEE MAX. JAMBANCHOR O.C. SPACING ONTABLES 12 & 13, USEKNEEWALL HEIGHTSEE SHEETS 9 & 10 FORANCHOR PATTERN,QUANTITY & SPACINGEXISTINGKNEEWALL BYOTHERSC12DOOR FRAME HEIGHTSOVER 97-3/4" OR DOORFRAME WIDTHS OVER39-1/2" REQUIRE SPECIALHARDWARE, SEESHEETS 18, 19, & 20.ENTRY DOOR NOTES:1. SEE SHEET 2 FOR EGRESS & DLO FORMULAS.2. SEE SHEETS 2 FOR ADDITIONAL DESIGN PRESSURE LIMITS BASED ON GLASS TYPE.6" MAX.24" MAXATTACHEDSTOREFRONTWINDOW,SEE SEPARATEAPPROVAL FORSPECIFICATIONSDOORDOOR + WINDOW FRAME WIDTH120" MAX.DOORFRAMEHEIGHT(OTHER DOOR TYPES SIMILAR)FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLEWIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE.KNEEWALLHEIGHTOVERALLHEIGHTADDED PAGE 20 TO SPECIAL HARDWARE NOTEHC04/13/21A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER 6" MAX. O.C.ANCHOR REQUIRED@ 3-7/8" MAX.ANCHOR REQUIRED@ 9-7/8" MAX.51-1/2" MAX.DOOR FRAME WIDTH1 INSTALLATIONANCHOR@ 3-7/8" MAX.THRU ANGLEBRACKETSEE MAX. JAMBANCHOR O.C. SPACINGON TABLES 12 & 13TYP. ELEVATION OF SINGLEDOOR WITH TRANSOMA12E13G14H14REINFORCEMENT #11REQUIRED IF USINGGLASS TYPES C OR FATTACHEDSTOREFRONTWINDOW,SEE SEPARATEAPPROVAL FORSPECIFICATIONSJ14120" MAX.OVERALLHEIGHT1/4" NUT & BOLT,24" FROM EACH ENDAND 24" MAX O.C.DOOR + WINDOW FRAME WIDTH97-3/4"MAX.DOORFRAMEHEIGHTSEE TABLE 5,THIS SHEET FORREINFORCEMENTTYPE17-7/8"MAX. O.C.D13I14SEE SHEET 17 FORANGLE BRACKET TOJAMB ATTACHMENT6" MAX. DOOR FRAME WIDTHSOVER 39-1/2" REQUIRESPECIAL HARDWARE, SEESHEETS 18, 19, & 20.42" MAX.TRANSOMHEIGHTSEE SHEETS 9 & 10 FOR ANCHORPATTERN, QUANTITY & SPACINGSEE SHEETS 9 & 10 FORANCHOR PATTERN,QUANTITY & SPACINGTABLE 5:STOREFRONT WINDOW NOTES:1. SEE SEPARATE APPROVAL FOR STOREFRONT WINDOW SPECIFICATIONS.2. IF A SERIES OF STOREFRONT WINDOWS ARE USED, USE ONLY 1 WINDOW DIRECTLY ADJACENT TO THE DOOR IN DETERMINING THE DOOR + WINDOW FRAME WIDTH.3. IF STOREFRONT WINDOWS ARE USED ON BOTH SIDES OF A DOOR (EX. OXO), DETERMINE THE DOOR + WINDOW FRAME WIDTH USING THE WIDER WINDOW.4. THE LESSER DESIGN PRESSURE OF THE DOOR OR STOREFRONT WINDOW SHALL GOVERN THE DESIGN PRESSURE FOR THE ENTIRE ASSEMBLY.5. SEE SHEET 4 FOR INSTALLATION TO KNEEWALL.ENTRY DOOR NOTES:1. SEE SHEET 2 FOR EGRESS & DLO FORMULAS.2. SEE SHEET 2 FOR ADDITIONAL DESIGN PRESSURE LIMITS BASED ON GLASS TYPE.DETAIL LETTERX#SHEET NUMBERNTS5 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKIFOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLEWIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE.ELEVATIONS FOR MULLION DP, BADDED PAGE 20 TO SPECIAL HARDWARE NOTEHC04/13/21A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER TYP. ELEVATION OF DOUBLE DOORWITHOUT TRANSOM, ATTACHED TOSTOREFRONT WINDOWANCHOR REQUIRED@ 3-7/8" MAX.ANCHOR REQUIRED@ 9-7/8" MAX.99-1/2" MAX. DOOR FRAME WIDTH17-7/8"MAX.O.C.SEE MAX. JAMBANCHOR O.C. SPACINGON TABLES 12 & 13INSTALL 1 ANCHOR @ 3-7/8"MAX. THRU ANGLE BRACKETATTACHEDSTOREFRONTWINDOW,SEE SEPARATEAPPROVAL FORSPECIFICATIONS6"MAX.A12J14B12D13E13120" MAX.DOORFRAME/OVERALLHEIGHT1/4" NUT & BOLT,24" FROM EACH ENDAND 24" MAX O.C.DOOR + WINDOW FRAME WIDTHTABLE 6:SEE TABLE 6,THIS SHEET FORREINFORCEMENTTYPESEE SHEET 17 FORANGLE BRACKET TOJAMB ATTACHMENTDOOR FRAME HEIGHTSOVER 97-3/4" OR DOORFRAME WIDTHS OVER75-1/2" REQUIRE SPECIALHARDWARE, SEE SHEETS18, 19, & 20.DETAIL LETTERX#SHEET NUMBERSEE SHEETS 9 & 10 FOR ANCHORPATTERN, QUANTITY & SPACINGSEE SHEETS 9 & 10 FORANCHOR PATTERN,QUANTITY & SPACINGNTS6 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKISEE SHEET 8 FORANCHOR QUANTITY& O.C. SPACINGSEE SHEET 8 FOR ANCHORQUANTITY & O.C. SPACINGSTOREFRONT WINDOW NOTES:1. SEE SEPARATE APPROVAL FOR STOREFRONT WINDOW SPECIFICATIONS.2. IF A SERIES OF STOREFRONT WINDOWS ARE USED, USE ONLY 1 WINDOW DIRECTLY ADJACENT TO THE DOOR IN DETERMINING THE DOOR + WINDOW FRAME WIDTH.3. IF STOREFRONT WINDOWS ARE USED ON BOTH SIDES OF A DOOR (EX. OXO), DETERMINE THE DOOR + WINDOW FRAME WIDTH USING THE WIDER WINDOW.4. THE LESSER DESIGN PRESSURE OF THE DOOR OR STOREFRONT WINDOW SHALL GOVERN THE DESIGN PRESSURE FOR THE ENTIRE ASSEMBLY.5. SEE SHEET 4 FOR INSTALLATION TO KNEEWALL.ENTRY DOOR NOTES:1. SEE SHEET 3 FOR EGRESS & DLO FORMULAS.2. SEE SHEET 3 FOR ADDITIONAL DESIGN PRESSURE LIMITS BASED ON GLASS TYPE.FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLEWIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE.ELEVATIONS FOR MULLION DP, CADDED PAGE 20 TO SPECIAL HARDWARE NOTEHC04/13/21A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER TYP. ELEVATION OF DOUBLE DOORWITH TRANSOM, ATTACHED TOSTOREFRONT WINDOW17-7/8"MAX .O.C.6" MAX. O.C.ANCHOR REQUIRED@ 3-7/8" MAX.ANCHOR REQUIRED@ 9-7/8" MAX.75-1/2" MAX. DOOR FRAME WIDTHSEE MAX. JAMBANCHOR O.C. SPACINGON TABLES 12 & 13H14A12B12F14E13G14INSTALL 1 ANCHOR@ 3-7/8" MAX.THRU ANGLEBRACKETJ14I14ATTACHEDSTOREFRONTWINDOW,SEE SEPARATEAPPROVAL FORSPECIFICATIONS120" MAX.OVERALLHEIGHT1/4" NUT & BOLT,24" FROM EACH ENDAND 24" MAX O.C.97-3/4"MAX.DOORFRAMEHEIGHTDOOR + WINDOW FRAME WIDTHTABLE 7:REINFORCEMENT #11REQUIRED IF USINGGLASS TYPES C OR FSEE TABLE 7,THIS SHEET FORREINFORCEMENTTYPESEE SHEET 17 FORANGLE BRACKET TOJAMB ATTACHMENT42" MAX.TRANSOMHEIGHTDETAIL LETTERX#SHEET NUMBERSEE SHEETS 9 & 10 FOR ANCHORPATTERN, QUANTITY & SPACINGSEE SHEETS 9 & 10 FORANCHOR PATTERN,QUANTITY & SPACINGNTS7 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKISEE SHEET 8 FORANCHOR QUANTITY& O.C. SPACING DOOR FRAME WIDTHSOVER 39-1/2" REQUIRESPECIAL HARDWARE,SEE SHEETS 18,19, & 20.STOREFRONT WINDOW NOTES:1. SEE SEPARATE APPROVAL FOR STOREFRONT WINDOW SPECIFICATIONS.2. IF A SERIES OF STOREFRONT WINDOWS ARE USED, USE ONLY 1 WINDOW DIRECTLY ADJACENT TO THE DOOR IN DETERMINING THE DOOR + WINDOW FRAME WIDTH.3. IF STOREFRONT WINDOWS ARE USED ON BOTH SIDES OF A DOOR (EX. OXO), DETERMINE THE DOOR + WINDOW FRAME WIDTH USING THE WIDER WINDOW.4. THE LESSER DESIGN PRESSURE OF THE DOOR OR STOREFRONT WINDOW SHALL GOVERN THE DESIGN PRESSURE FOR THE ENTIRE ASSEMBLY.5. SEE SHEET 4 FOR INSTALLATION TO KNEEWALL.ENTRY DOOR NOTES:1. SEE SHEET 3 FOR EGRESS & DLO FORMULAS.2. SEE SHEET 3 FOR ADDITIONAL DESIGN PRESSURE LIMITS BASED ON GLASS TYPE.FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLEWIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE.ELEVATIONS FOR MULLION DP, DADDED PAGE 20 TO SPECIAL HARDWARE NOTEHC04/13/21A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER TABLE 8:TABLE 9:A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296 PREPARED BY: A. LYNN MILLER 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275; (941) 480-1600 CGI WINDOWS AND DOORS, INC. 10100 NW 25TH STREET MIAMI, FL 33172 (305) 593-6590 B COPYRIGHT ©2021 CGI WINDOWS & DOORS, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER 6" MAX. O.C.,SEE TABLE 1 FOR MIN. O.C. SPACINGSEE TABLES 8 & 9, THIS SHEETFOR ANCHOR QUANTITY6" MAX. O.C.,SEE TABLE 1 FOR MIN. O.C. SPACINGSEE TABLES 8 & 9, THIS SHEETFOR ANCHOR QUANTITY (NOTREQUIRED IF TRANSOM IS USED)DOORDOORTYP. ANCHORPATTERN FOR HEADSAND SILLS OFDOUBLE DOORS ATTHE MEETING STILESNTS 8 OF 20 STOREFRONT ENTRANCE DOOR DETAILS - LM SE-3550 MD-3550.2-LM 03/05/16 J ROSOWSKICLUSTER ANCHORS (DOUBLE DOOR)FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWNON THE TABLE.FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWNON THE TABLE. A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296 PREPARED BY: A. LYNN MILLER 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275; (941) 480-1600 CGI WINDOWS AND DOORS, INC. 10100 NW 25TH STREET MIAMI, FL 33172 (305) 593-6590 B COPYRIGHT ©2021 CGI WINDOWS & DOORS, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER TABLE 10:NTS 9 OF 20 STOREFRONT ENTRANCE DOOR DETAILS - LM SE-3550 MD-3550.2-LM 03/05/16 J ROSOWSKICLUSTER ANCHORS, MULL, 1/4" SHIM WINDOWDOORANCHOR PATTERN IF(4) ANCHORS AREREQUIRED PER TABLE10 (THIS SHEET)4" MAX. O.C., SEE TABLE1 FOR MIN. O.C. SPACING4" MAX. O.C., SEE TABLE1 FOR MIN. O.C. SPACING4-1/2" MAX. O.C. @ CENTERLINECLCL4-1/2" MAX. O.C.@ CENTERLINEWINDOWDOOR4" MAX. O.C., SEE TABLE1 FOR MIN. O.C. SPACING4" MAX. O.C., SEE TABLE1 FOR MIN. O.C. SPACING4-1/2" MAX. O.C. @ CENTERLINECLCL4-1/2" MAX. O.C. @ CENTERLINEWINDOWDOOR4" MAX. O.C., SEE TABLE1 FOR MIN. O.C. SPACING4" MAX. O.C., SEE TABLE1 FOR MIN. O.C. SPACING4-1/2" MAX. O.C. @ CENTERLINECLCL4-1/2" MAX. O.C. @ CENTERLINEANCHOR PATTERN IF(6) ANCHORS AREREQUIRED PER TABLE10 (THIS SHEET)ANCHOR PATTERN IF(8) ANCHORS AREREQUIRED PER TABLE10 (THIS SHEET)FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296 PREPARED BY: A. LYNN MILLER 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275; (941) 480-1600 CGI WINDOWS AND DOORS, INC. 10100 NW 25TH STREET MIAMI, FL 33172 (305) 593-6590 B COPYRIGHT ©2021 CGI WINDOWS & DOORS, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER WINDOWDOORANCHOR PATTERN IF(4) ANCHORS AREREQUIRED PER TABLE11 (THIS SHEET)4" MAX. O.C., SEE TABLE1 FOR MIN. O.C. SPACING4" MAX. O.C., SEE TABLE1 FOR MIN. O.C. SPACING4-1/2" MAX. O.C. @ CENTERLINECLCL4-1/2" MAX. O.C.@ CENTERLINEWINDOWDOOR4" MAX. O.C., SEE TABLE1 FOR MIN. O.C. SPACING4" MAX. O.C., SEE TABLE1 FOR MIN. O.C. SPACING4-1/2" MAX. O.C. @ CENTERLINECLCL4-1/2" MAX. O.C. @ CENTERLINEWINDOWDOOR4" MAX. O.C., SEE TABLE1 FOR MIN. O.C. SPACING4" MAX. O.C., SEE TABLE1 FOR MIN. O.C. SPACING4-1/2" MAX. O.C. @ CENTERLINECLCL4-1/2" MAX. O.C. @ CENTERLINEANCHOR PATTERN IF(6) ANCHORS AREREQUIRED PER TABLE11 (THIS SHEET)ANCHOR PATTERN IF(8) ANCHORS AREREQUIRED PER TABLE11 (THIS SHEET)NTS 10 OF 20 STOREFRONT ENTRANCE DOOR DETAILS - LM SE-3550 MD-3550.2-LM 03/05/16 J ROSOWSKICLUSTER ANCHORS, MULL, 1/2" SHIM TABLE 11:FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296 PREPARED BY: A. LYNN MILLER 1070 TECHNOLOGY DRIVE N. VENICE, FL 34275; (941) 480-1600 CGI WINDOWS AND DOORS, INC. 10100 NW 25TH STREET MIAMI, FL 33172 (305) 593-6590 B COPYRIGHT ©2021 CGI WINDOWS & DOORS, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER 6" MAX.SEE TABLES12 & 13,THIS SHEETTABLE 12:TABLE 13:6" MAX. O.C.6" MAX.SEE TABLES12 & 13,THIS SHEETJAMB ANCHORPATTERN FOR SINGLEAND DOUBLE DOORS(SHOWN WITHTRANSOM, WITHOUTTRANSOM SIMILAR)NTS 11 OF 20 STOREFRONT ENTRANCE DOOR DETAILS - LM SE-3550 MD-3550.2-LM 03/05/16 J ROSOWSKIJAMB ANCHORS DOORFOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHTDIMENSION SHOWN ON THE TABLE.FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHTDIMENSION SHOWN ON THE TABLE. NOTES:1. USE ONLY SUBSTRATE APPROPRIATE ANCHORS, FOLLOW EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS PER TABLE 1, SHEET 1. ANY INSTALLATION OPTION SHOWN MAY BE USED. ALL ANCHOR HEAD TYPES ARE ALLOWED.2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY BE INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD.HORIZONTAL X-SECTIONA. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER DAYLIGHTOPENING WIDTH451259575063OPTIONALLAMI IG GLASS218434369OPTIONALPANIC BAR685231/2" MAX.EDGEDISTANCEEMBEDMENT1X OR 2XWOOD BUCKSTRIP,SEE NOTE 4, SHEET 1DETAIL C21/2" MAX.CONCRETE/CMU PERANCHOR REQUIREMENTTYP. ANCHOR TYPE,EMBEDMENT AND EDGEDISTANCE PER SUBSTRATE,SEE TABLE 1, SHEET 1EMBEDMENTEDGEDISTANCEDETAIL A1THRU 1X WOODDETAIL BMEETING STILESDETAIL C1INTO METALINTO MASONRY1/2" MAX.EDGEDISTANCEEMBEDMENTTYP. ANCHOR TYPE,EMBEDMENT AND EDGEDISTANCE PER SUBSTRATE,SEE TABLE 1, SHEET 1CONCRETE/CMU PERANCHORREQUIREMENTEXTERIORDOOR FRAME WIDTHDAYLIGHTOPENING WIDTH451255431364595721634OPTIONALLAMI IG GLASS21843432265OPTIONAL3-POINT LOCK69OPTIONALPANIC BAR6862MIN. 7" LONG56477522560DETAIL A2INTO 2X WOODHORIZONTAL SECTION (DOUBLE DOOR)TYP. ANCHOR TYPE,EMBEDMENT ANDEDGE DISTANCE PERSUBSTRATE, SEETABLE 1, SHEET 1DADE APPROVEDMULLION, FBCCOMPLIANTALUMINUM/STEELFRAMING ORSTEEL STUD. MAYBE VERTICAL ORHORIZONTAL. SEESUBSTRATEPROPERTIES,TABLE 1, SHEET 11/2" MAX.EDGE DISTANCEEMBEDMENTCONCRETE/CMU PERANCHOR REQUIREMENTTYP. ANCHOR TYPE,EMBEDMENT AND EDGEDISTANCE PER SUBSTRATE,SEE TABLE 1, SHEET 1DOOR FRAME WIDTHHORIZONTAL SECTION(SINGLE DOOR)EXTERIORINTO MASONRYNTS12 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKI31OPTIONAL#8 X 3/4"SMS DETAIL D3INTO MASONRYEDGEDISTANCEEMBEDMENTDADE APPROVED MULLION, FBCCOMPLIANT ALUMINUM/STEEL FRAMINGOR STEEL STUD. MAY BE VERTICAL ORHORIZONTAL. SEE SUBSTRATEPROPERTIES, TABLE 1, SHEET 1DETAIL D4INTO METALDETAIL D2INTO WOOD1/2"MAX.2X WOOD BUCKSTRIP OR FRAMING,SEE ANCHOR NOTE 3, SHEET 11/2" MAX. SHIM OR 5 KSINON- SHRINK,NON-METALLIC GROUT,FULL LENGTHDOORFRAME/OVERALLHEIGHTSADDLETHRESHOLD1/4" HEIGHT84312431315*NOTES:1. USE ONLY SUBSTRATE APPROPRIATE ANCHORS, FOLLOW EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS PER TABLE 1, SHEET 1. ANY INSTALLATION OPTION SHOWN MAY BE USED. ALL ANCHOR HEAD TYPES ARE ALLOWED.2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY BE INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD.621OPTIONALBUG FLAP46TABLE 14:1252*SEE SHEET 17 FOR REQUIRED ATTACHMENT OF THRESHOLD ANGLEFOR DESIGN PRESSURECONSTRAINTS ON PARTS 15-18,SEE TABLE 14, THIS SHEET.REFER TOSHEETS 18 & 19FOR MIN. THROWREQUIREMENTS525252A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER 14*5452X WOOD BUCKSTRIPOR FRAMING, SEEANCHOR NOTE 3,SHEET 1EMBEDMENT1/2"MAX.CONCRETE/CMU PERANCHOR REQUIREMENTEMBEDMENTEMBEDMENT1/2"MAX.EDGEDISTANCEEDGEDISTANCEEDGEDISTANCE1/2"MAX.DETAIL D11X WOOD BUCKSTRIP, SEENOTE 2, THIS SHEET.3" = TOTALSILL HEIGHT18#18 SHOWN#16-17 ALSO APPLYCOVER(1/2" TOTAL SILL HEIGHT)ADA THRESHOLDCOVER(1-1/2" TOTAL SILL HEIGHT)1-1/2" THRESHOLDCOVER(3" TOTAL SILL HEIGHT)3" THRESHOLD181716CONCRETE/CMU PERANCHOR REQUIREMENTEMBED-MENTEMBED-MENTEDGEDISTANCEEDGEDISTANCETYP. ANCHOR TYPE, EMBEDMENTAND EDGE DISTANCE PERSUBSTRATE, SEE TABLE 1, SHEET 1DETAIL E2INTO WOODTYP. ANCHOR TYPE,EMBEDMENT ANDEDGE DISTANCE PERSUBSTRATE, SEETABLE 1, SHEET 1DETAIL E1INTO MASONRYCONCRETE/CMUPER ANCHORREQUIREMENTTYP. ANCHOR TYPE,EMBEDMENT ANDEDGE DISTANCE PERSUBSTRATE, SEETABLE 1, SHEET 1TYP. ANCHOR TYPE,EMBEDMENT ANDEDGE DISTANCE PERSUBSTRATE, SEETABLE 1, SHEET 1TYP. ANCHOR TYPE,EMBEDMENT ANDEDGE DISTANCE PERSUBSTRATE, SEETABLE 1, SHEET 1TYP. ANCHOR TYPE,EMBEDMENT ANDEDGE DISTANCE PERSUBSTRATE, SEETABLE 1, SHEET 1EXTERIOREXTERIOREXTERIOREXTERIOR61B, 63B, 66B,.050".063".063"2.239"2.239"2.032"2.921"1.421".293"VERTICAL SECTION(DOOR)THRU 1X WOODINTO MASONRYOH LENGTHOH HEIGHT FIG 1:DOOR ASSEMBLIESINSTALLED WHERE THEOVERHANG (OH) LENGTHIS EQUAL TO ORGREATER THAN THEOVERHANG HEIGHT ISEXEMPTED FROM WATERINFILTRATIONRESISTANCE.1) IF WATER INFILTRATIONRESISTANCE ISREQUIRED, TABLE 14MUST BE USED TODETERMINE THE WATERLIMITED (+) DP.2) IF WATER INFILTRATIONRESISTANCE IS NOTREQUIRED OR ANOVERHANG IS AS PER FIG1, ANY THRESHOLD MAYBE USED.NTS13 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKIVERTICAL X-SECTION10DAYLIGHTOPENINGHEIGHT70B, 0R 72BOPT. 10" ADABOTTOMRAIL, #19.(STANDARDBOTTOM RAILSHOWN) ALUMINUMREINFORCEMENT4.541"1.223".125"EXTERIOREXTERIOR9242023111-3/8"1-3/4"HD ALUMINUMREINFORCEMENT4.690".189"A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER 4312146EXTERIOR2143DETAIL FDETAIL GDETAIL JATTACHEDSTOREFRONTWINDOW,SEE SEPARATEAPPROVAL FORSPECIFICATIONS1/4" NUT & BOLT, 24"MAX. FROM EACHEND AND 24" MAX O.C.ATTACHEDSTOREFRONTWINDOW,SEE SEPARATEAPPROVAL FORSPECIFICATIONSVERTICALSECTION(TRANSOM)VERTICAL SECTION(DOOR HEAD)HORIZONTAL SECTION(TRANSOM TO STOREFRONT WINDOW)HORIZONTAL SECTION(TRANSOM JAMB)HORIZONTAL SECTION(DOOR TO STOREFRONT WINDOW)REINFORCEMENT #11 OR #23REQUIRED FOR ALL DOORSUSING GLASS TYPES C OR FREINFORCEMENT #11 OR #23REQUIRED FOR ALL DOORSUSING GLASS TYPES C OR F11231.110"DOORFRAMEHEIGHT920EXTERIOREMBEDMENT1/2"MAX.CONCRETE/CMU PERANCHOR REQUIREMENTEDGEDISTANCE1/2" MAX.EDGEDISTANCEEMBEDMENT1X OR 2X WOOD BUCKSTRIP,SEE NOTE 4, SHEET 1CONCRETE/CMU PERANCHOR REQUIREMENTTYP. ANCHOR TYPE,EMBEDMENT AND EDGEDISTANCE PER SUBSTRATE,SEE TABLE 1, SHEET 1DETAIL HTHRU 1X WOODINTO MASONRYINTO MASONRYTYP. ANCHOR TYPE, EMBEDMENTAND EDGE DISTANCE PERSUBSTRATE, SEE TABLE 1, SHEET 1NTS14 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKITRANSOM X-SECTIONTRANSOMHEIGHTOVERALLHEIGHTTRANSOM WIDTHNO REINFORCEMENTREQUIRED IN JAMBSATTACHED TOSUBSTRATE298810#10 X 3/4" PH SMS, 3"FROM EACH ENDAND 8-1/8" MAX O.C.1/4" NUT & BOLT, 24" MAX.FROM TOP OF FRAME,REQUIRED FOR TRANSOMHEIGHTS OVER 22-1/4"DETAIL ITRANSOM TOSTOREFRONT WINDOWNOTES:1. USE ONLY SUBSTRATE APPROPRIATE ANCHORS, FOLLOW EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS PER TABLE 1, SHEET 1. ANY INSTALLATION OPTION SHOWN MAY BE USED. ALL ANCHOR HEAD TYPES ARE ALLOWED.2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY BE INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD.REINFORCEMENT #11REQUIRED FOR ALLDOORS USING GLASSTYPES C OR F113534324881049THIS DOOR SYSTEMMAY BE USED WITHANY COMPATIBLECGI-COMMERCIALSTOREFRONTWINDOW SYSTEM(SS-3520 TRANSOMSHOWN AS EXAMPLE)33COMPATIBLECGI-COMMERCIALSTOREFRONT WINDOWSYSTEMJR09/15/20ADDED PARTS #24, #48 & #49 GLAZING DETAILSNOTES:1. GLAZING FOR ALL GLASS TYPES MEETS ASTM E1300 FOR ALL APPROVED DOOR PANEL AND TRANSOM SIZES."PVB" = .090" TROSIFOL® PVB INTERLAYER BY KURARAY AMERICA, INC."SG" = .090" SENTRYGLAS® INTERLAYER BY KURARAY AMERICA, INC.GLASS TYPE A9/16" LAMINATEDGLASS STACK1/4" ANNEALEDGLASS1/4" ANNEALEDGLASS.090" SGGLASS TYPE D1-3/16" I.G.GLASS STACK1/4" ANNEALEDGLASS1/4" TEMPEREDGLASS.090" SG7/16" AIRSPACE9/16" LAMINATEDGLASS STACKGLASS TYPE C9/16" LAMINATEDGLASS STACK1/4" HEAT-STRENGTHENEDGLASS1/4" HEAT-STRENGTHENEDGLASS.090" SGGLASS TYPE E1-3/16" I.G.GLASS STACK1/4" HEAT-STRENGTHENEDGLASS1/4" TEMPEREDGLASS.090" PVB7/16" AIRSPACE9/16" LAMINATEDGLASS STACKGLASS TYPE B9/16" LAMINATEDGLASS STACK1/4" HEAT-STRENGTHENEDGLASS1/4" HEAT-STRENGTHENEDGLASS.090" PVBGLASS TYPE F1-3/16" I.G.GLASS STACK1/4" HEAT-STRENGTHENEDGLASS1/4" TEMPEREDGLASS.090" SG7/16" AIRSPACE9/16" LAMINATEDGLASS STACK11/16" GLASSBITE40444311/16" GLASSBITE40444311/16" GLASSBITE41444311/16" GLASSBITE40444311/16" GLASSBITE41444311/16" GLASSBITE414443393939XL EDGE SPACERDURASEAL SPACERSUPER SPACER NXTINT. GLASSBUTYL &DESICCANTFOAMSTRUCTURALSILICONEFOAMWITHDESICCANTROLL-FORMEDSTAINLESS STEELEXT. GLASSALUMINUMREINFORCEMENTPOLYISO-BUTYLENESEALSILICONE SEALINT. GLASSEXT. GLASSINT. GLASSEXT. GLASSDESICCANT FILL AREAHOT-MELT BUTYLR5/16" NOM.3/16" NOM.5/16" NOM.KODISPACE 4SG TPSSTRUCTURALPOLYISOBUTYLENEWITH DESICCANTINT. GLASSEXT. GLASSSILICONE1/4" NOM.A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER 38363739EXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIORNTS15 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKIRTMTMR STOREFRONT ENTRANCE DOOR DETAILS - LMTABLE 15:A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER 3.309"4.968"1.750".125".188".125".094"89TRANSOMBASEDOOR JAMB/FRAME HEAD12137LOCKSTILEBACKERPLATE.618"1.470".250".360"15SADDLETHRESHOLD4.740".063".229"4.192"6FLATSNAP COVER.342".094"4PANEL STILE,HINGE/INACTIVE4.626"4.625"6.874"5.744"1.686"1.686"1.750"1.750".125".125".120".145".100".125"1.555".100"1.425".050"5RAILU-CHANNEL3PANEL STILE,HINGE2PANELBOTTOM RAIL1PANELTOP RAIL4.968"1.750".125".188"10DOORHEAD14BUMPERTHRESHOLD4.160".500".063"2.185"1.121".062"20TRANSOMBEAD, 9/16"21GLAZING LEG,IG BEAD.630"1.070".075"25PANEL STILE,LOCKING/ACTIVE26DOORSHEAR BLOCKDOORSTOP COVERDOORSTOP BASE4.615".125"1.750"3.592"1.398".188".610"2.058".050"1.391".575".050"29WINDOWFRAME28TRANSOMGLAZING ADAPTER1.750".094"5.000"4.193".125".094"1.453".610"1.485".050"27DOOR NARROWSTOP COVER30DOOR NARROWSTOP BASE.890".575".050"1. PARTS 30, 42 & 50 ARE NOT USED AND ARE NOT PART OF THIS APPROVAL.2. FOR PARTS 60-73, SEE HARDWARE BOM ON SHEETS 18, 19, & 20.3. ADDITIONAL EXTRUSIONS ON SHEETS 13, 14 & 17.NTS16 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKIBOM & EXTRUSIONS1.095".867".159"31ASTRAGAL32HORIZONTAL33TRANSOM ADAPTER4.597".094"1.453"ADAPTER5.001".094"1.250"1910" BOTTOMRAIL10.000"1.688".108"HEAD/SILL/HORIZONTAL4.192"49FLAT FILLER PLATE.454".094"485.000".094"2.000"(USED WITH NON-REINF. MULLION)HC04/13/21REVISED NOTE 2 TO INCLUDE PAGES 18 & 20JR09/15/20ADDED PARTS #48 & #49 4-1/2"8-1/2"4"1-1/2"CORNER DETAILSEXTERIORFRAME DETAILS,DOOR SLAB2" X 5" X 1/8"THRESHOLDANGLE(1-3/4" WIDE)FOR CLARITY, GLASS,BEADING & THE ANCHORPLATE ARE NOT SHOWN.@ DOOR2910537554265151537456551416154A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER TRANSOMBEAD, 1-1/4"1.121"1.462".062"22DOORBEAD, 9/16".814"1.070".062"24DETAILSBOTTOMOF DOORTOP OFDOORFRAME DETAILS,@ TRANSOMNTS17 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKIEXTERIORDOOR SILLDOORHEADERTRANSOMHEADER6063-T5 ALUMINUM HINGEBACKER PLATE AT EACHHINGE LEAF, 0.250" THICK5957REGENT SERIES 4001 BUTTHINGE, 8" FROM EACH END ANDMAX. 26" O.C.; 0.134" THICK35LAMI IG BEAD3.154".062"1.121"34LAMI BEAD3.853".062"1.121" LOCK OPTION #3 (RESIDENTIAL)3-POINT LOCK SYSTEMREGENT SERIES 206.2-3PLEVER WITH KEY ON EXT.LEVER WITH THUMB-TURN ON INT.2-POINT LOCK SYSTEMREGENT SERIES ML207-TT-2PTINT./EXT. LEVERLOCK OPTION #12-POINT PANIC BAR, ALL SLABSREGENT SERIES 5770OPT. KEY OPERATED ON EXT.OPT. KEY/THUMB-TURN ON INT.LOCK OPTION #22-POINT PANIC BAR, ALL SLABSVON DUPRIN SERIES 3347OPT. KEY OPERATED ON EXT.OPT. KEY/THUMB-TURN ON INT.ALLSLABSACTIVE646562ALLSLABSACTIVEFOR ALL SLABS:LOCK FOR ALL SLABS:LOCK FOR ACTIVE SLAB:NTS18 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKIHARDWARE A66ALOCK FOR NON-ACTIVE SLAB:605/8" PULLMAN LATCH61ATOP LATCH FOR ALL SLABS:5/8" PIVOT LATCH63ATOP LATCH FOR ALL SLABS:11/16" THROW BOLT LATCH61BBOTTOM LATCH FOR ALL SLABS:5/8" PIVOT LATCH63BBOTTOM LATCH FOR ALL SLABS:5/8" THROW BOLT LATCHTOP LATCH FOR ALL SLABS:11/16" THROW BOLT LATCH66BBOTTOM LATCH FOR ALL SLABS:(MAX. DP OF +90.0/-120.0)(MAX. DP OF +90.0/-120.0)(MAX. DP OF +90.0/-120.0)TABLE 16A:STYLE MAYDIFFER FROMSHOWNADDED MISSING DETAILS TO CURRENT LOCKSHC04/13/21A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER 3-POINT LOCK SYSTEMREGENT SERIES 2222KEY OPERATED ON EXT.THUMB-TURN ON INT.2-POINT LOCK SYSTEMREGENT SERIES 2-PT-LKEY OPERATED ON EXT.THUMB-TURN ON INT.6768LOCK FOR ACTIVE SLABS:LOCK FOR NON-ACTIVE SLABS:NTS19 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKIHARDWARE B69ALOCK OPTION #4 (COMMERCIAL)1/2" THROW BOLT LATCHTOP LATCH FOR ALL SLABS:69B1/2" THROW BOLT LATCHBOTTOM LATCH FOR ALL SLABS:(MAX. DP OF +90.0/-120.0)3-POINT LOCK SYSTEMREGENT SERIES 2222KEY OPERATED ON EXT.THUMB-TURN ON INT.2-POINT LOCK SYSTEMREGENT SERIES 2-PT-LKEY OPERATED ON EXT.THUMB-TURN ON INT.6768LOCK FOR ACTIVE SLABS:LOCK OPTION #5 (HD COMMERCIAL)REQUIRED FOR DOOR FRAME HEIGHTSOVER 97-3/4" OR DOOR FRAME WIDTHSOVER 39-1/2" (SINGLE) OR 75-1/2" (DOUBLE).70ABOLT GUIDE BLOCK5/8" THROW BOLT LATCHTOP LATCH FOR ALL SLABS:70BBOLT GUIDE BLOCK11/16" THROW BOLT LATCHBOTTOM LATCH FOR ALL SLABS:(MAX. DP OF +90.0/-100.0)TABLE 16B:LOCK FOR NON-ACTIVE SLABS:STYLE MAYDIFFER FROMSHOWNSTYLE MAYDIFFER FROMSHOWNMOVED LOCK OPTION 6 TO PAGE 20; ADDED MISSING DETAILSTO CURRENT LOCKSHC04/13/21A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER LOCK OPTION #6REQUIRED FOR DOOR FRAME HEIGHTSOVER 97-3/4" OR DOOR FRAME WIDTHSOVER 39-1/2" (SINGLE) OR 75-1/2" (DOUBLE).2-POINT PANIC BAR, ALL SLABSJACKSON SERIES XXXXOPT. KEY OPERATED ON EXT.OPT. KEY/THUMB-TURN ON INT.71ALLSLABSACTIVELOCK FOR ALL SLABS:72AJACKSON BOLT GUIDE BLOCK1/2" THROW BOLT LATCHTOP LATCH FOR ALL SLABS:72BJACKSON BOLT GUIDE BLOCK1/2" THROW BOLT LATCHBOTTOM LATCH FOR ALL SLABS:73(MAX. DP OF +90.0/-100.0)NTS20 OF 20STOREFRONT ENTRANCE DOOR DETAILS - LMSE-3550MD-3550.2-LM03/05/16J ROSOWSKIHARDWARE CLOCK OPTION #7REQUIRED FOR DOOR FRAME HEIGHTSOVER 97-3/4" OR DOOR FRAME WIDTHSOVER 39-1/2" (SINGLE) OR 75-1/2" (DOUBLE).60ALLSLABSACTIVELOCK FOR ALL SLABS:61CCUSTOM HD BOLT GUIDE BLOCK1/2" THROW BOLT LATCHTOP LATCH FOR ALL SLABS:61DCUSTOM HD BOLT GUIDE BLOCK1/2" THROW BOLT LATCHBOTTOM LATCH FOR ALL SLABS:73(MAX. DP OF +90.0/-100.0)TABLE 16C:2-POINT PANIC BAR, ALL SLABSREGENT SERIES 5770OPT. KEY OPERATED ON EXT.OPT. KEY/THUMB-TURN ON INT.ADDED LOCK OPTION 7; ADDED MISSING DETAILS TO LOCKOPTION 6HC04/13/21A. LYNN MILLER, P.E.P.E.# 58705CERT. OF AUTH. #29296PREPARED BY: A. LYNN MILLER1070 TECHNOLOGY DRIVEN. VENICE, FL 34275; (941) 480-1600CGI WINDOWS AND DOORS, INC.10100 NW 25TH STREETMIAMI, FL 33172; (305) 593-6590BCOPYRIGHT ©2021CGI WINDOWS & DOORS, INC.LIMITED LICENSE TO MAKECOPIES FOR PERMITTING.No. 58705STATEOFRIDOLFA4/14/21LCENSEIA N T HONYLYNNMILLERPROFESSIONALENGI N EER