HomeMy WebLinkAboutDoor Replacement PlanRECEIVED SEP1®ZU, St. Lucia County ermitting REPLACE DOOR IN 1 OPENING ONLY NEW DOOR TO BE IMPACT RESISTANT - HURRICANE SHUTTERS NOT REQUIRED. File C®vv A4240�l RFVIEWED FOR CODE COMPLIANCE ST. L CIE COUNTY OCC �/14l2( OPENING PRODUCT DESIGN OPENING SQ. I WIND I PRESSURES APPROVAL PRESSURES I COMMENTS NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A. #) POS. NEG. 1 36 T 80 20.00 4 57.7 1 -59.0 FL16708.1 1 65.0 1 -65.0 1 FRONT ENTRY - LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH MINIMUM 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2020 ENERGY CONSERVATION CODE. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT = 105 FT 9 IN LASHLEY CONDO UNIT 10044 S. OCEAN DRIVE, UNIT 1005 JENSEN BEACH, FLORIDA DOOR REPLACEMENT PLAN i4tz)14( ENGINEERING EXPRESS ° Date: August 31 st, 2021 94180 1 44439-5454861111 1 Page 1/1 ASCE 7 Components & Cladding Wall Pressure Calculator``��,,,,,I�,��, Prepared For: J&G CARPENTRY, INC 7030 SW 16TH COURT RECEIVED PEMBROKE PINES FL Project: LASHLEY CONDO DOOR REPL)�CAIR402' St. Lucie County Project Address: Permitting 10044 S. OCEAN DRIVE UNIT 1005 JENSEN BEACH Florida \�. .,i No 4654- STATE O ..4011110 Box for Engineer Seal Only -Original Rqd for Permit & Use Frank Bennardo, PE FL46549 or Richard Neet, PE FL86488 The following has been considered in determining allowable stress design (ASD) wall opening pressures for the above - referenced location. ASCE: ASCE 7-16 (7TH EDN FLORIDA BUILDING CODE, 2020 FBC, 2018 IBC) Wind Velocity: 170 MPH Exposure Category: D Kd: 0.85 Kzt: 1 Minimum Building Dimension: 134FT Mean Roof Height: 106FT Unit Elevation: 90FT ROOF SLOPE: FLAT (<100) Number Of Openings: 1 Shutter: NO Mark: 1 Height Of Opening: 80 IN Width Of Opening: 36 IN Zone: 4 Based on the above, the following ASD design pressures apply for the opening marks which shall correspond with contractor -supplied building layout: a: 13.4 FT Mark: 1 Wall Positive Pressure: 57.7PSF Wall Negative Pressure: -59PSF MEm RO HUGHTEMRHI IWI[IIH S a� s �'a;k ELEVATION 1"a, LEAST HORIZONTAL DIMENSION J s 5 WIND_, FLOW PLAN VIEW \O COMPLEX 5 5 CORNERS BUILDINGS> 60' ROOF HEIGHT R'=10960F LEAST HORIZONTAL DIMENSION OR 40%OF MEAN ROOF HEIGHT (MRH), WHICHEVER 15 LESS BUT NOT<4XOF LEAST HORIZONTAL DIMENSION ORSFT. "USE CORNER IONES IF AT ALL IN QUESTION. SHUTTER OPTION FORCES OUTPUT TO HEIGHT • HEIGHT/ S. File Copy REVIEWED FOR CODE COMPLIANCE ST. lLUCIE COUNTY R®CC Design pressure results are in accordance with the Building & ASCE 7 codes listed above for an ENCLOSED structure only (Gcpi=+-0.18). Results are based on contractor -supplied data and are not field verified by this office. Input shall be verified by others prior to permit & use. Selection of all components & their respective approvals shall be by others and are to be within the ASD design pressure limitations stated herein. Results only valid with original or verifiable digital seal by a licensed PE of this firm. For more information on any of the terms listed herein, or to use a design tool to evaluate your openings, visit Engineering Express.com/Wind.