Loading...
HomeMy WebLinkAboutProduct Approval; Swinging Exterior Door Assemblies398 E. Dania Beach Blvd. BUILDING DROPS Suite338 Dania Beach, FL 33004 lnIA\\ A Perfect Solution in Every Drop 954.399.8478 PH Certificate of Authorization: 29578 954.744.4738 FX contact@buildingdrops.com April 27, 2015 TO: Whom It May Concern FROM: Hermes F. Norero, P.E. Registered Florida Professional Engineer #73778 MANUFACTURER: JELD-WEN, inc. 3737 Lakeport Blvd. Klamath Falls, OR. 97601 Dear Sir (Madam), To the best of my knowledge, the above -mentioned product conforms to the current edition of the Florida Building Code. Please note that I do not have, nor will I acquire, a financial interest in any company manufacturing or distributing the product(s) for which the reports are being issued. I also do not have, nor will I acquire, any financial interest with the Laboratory that performed the test(s), or with the Engineer witnessing the test(s) and sealing the test report(s). Respectfully submitted, ```tillIIII�r7��'' Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date: 2015.04.27 20:14:19-04'00' Hermes F. Norero, P.E. Florida Registered Professional Engineer #73778 Page 1 of 1 Florida Building,Code Online BCIS Home Log In User Registration ( Hot Topics I Submit Surcharge I Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval r USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived RECEIVED SEP 1;® 2021 St. Lucie County Permitting Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL16708-R13 Revision 2020 Approved JELD-WEN 3737 Lakeport Blvd Klamath Falls, OR 97601 (800)535-3936 fbcl@jeld-wen.com Rylee Sumner Fricks fbcl@jeld-wen.com File Copy 9iEer);�vU CODE COMPLIAPICY ST. L CIE C UN."t 0 0, c Iz/ JELD-WEN Corporate Customer Service 3737 Lakeport Blvd. Klamath Falls, OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Exterior Doors Swinging Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Hermes F. Norero, P.E. Evaluation Report Florida License PE-73778 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2022 Validated By Locke Bowden P.E. I] Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards FL16708 R13 COI COIJW SS 2015-04-27.odf Standard TAS 201 TAS 202 TAS 203 Year 1994 1994 1994 }rttp://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu8obl%2flZm6TudWOg6cFUIGz%2bYuNViQ9olAo7zp34bbWg%3d%3d[l2/16/20203:25:39 PM] Florida Building Code Online Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Florida Licensed Professional Engineer or Architect FL16708 R13 Eq iv 23549 1 Equivalency of ASTM E84 13a and A,,r-TM E84-16.pddf Method 1 Option D 08/03/2020 10/08/2020 10/16/2020 12/15/2020 bummary,or�,rroauccs ...... -- — �FL # y : _ _ .. — .Mlotlel, "Number or Name ., Descriptions,. 16708.1 A Design Pro / Smooth Pro / Studio Single (X) Impact Opaque Door 3-0 x 6-8 and 3-0 x 8-0 Fiberglass -..... ... .... ...... _........ ..... ...—__ _.—_............. _... -........ -- .... Inswing and Outswing _._.._ Limits of Use —----..._—.__..... _........ __ ............. .................. --._._... .... --- ........... ........ .......— ---+ Installation Instructions Approved for use in HVHZ: Yes FL16708 R1.3 II 16708.1 SS 201.9-10-Q1,odf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. 73778 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: FL16708 R13 AE PER4663.2 SS 2019-10-01.[�df Created by Independent Third Party: Yes 16708.2 B Design Pro Smoot Pro Fi rerg I crass Singe X Impact Glazed Door 3-0 x 6-8 an 3-0 x 8-0 Inswing and Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16708 R13 II 16708.2 SS 01-10-01.pddf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. 73778 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: FL16708 R13 AE PER4438,3 SS 2019-12-13.1df Created by Independent Third Party: Yes 16708.3 C Design Pro / Smooth Pro / Studio Double (XX) Impact Opaque Door 6-0 x 6-8 and 6-0 x 8-0 Fiberglass ._ —---...---..._._..._......._.._..-_.. ._......._. __..._.____...._... Inswing and Outswing j ---- Limits of Use _ -- _---- .....................................—......_..__._._—.....---.._........... ......._..__ Installation Instructions Approved for use in HVHZ: Yes FL16708 R13 II D015727-DP SP OPQ LMI HHVZ XO FBC SS 201.9-12-12.12df Approved for use outside HVHZ: Yes Impact Resistant: Yes Verified By: Hermes F. Norero, P.E. 73778 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL16708 R13 AE PER4664.2 SS 2019-10-01.pdf Created by Independent Third Party: Yes 16708.4 — D Design Pro / Smooth Pro Fiberglass Double (XX) Impact Glazed Door 6-0 x 6-8 and 6-0 x 8-0 Inswing and Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16708 R13 II D015705 - DP SP GLZ LMI HVHZ XO FBC SS 2019-12-12.odf Approved. for use outside HVHZ: Yes Impact Resistant: Yes Verified By: Hermes F. Norero, P.E. 73778 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL16708 R13 AE PER4440.2 SS 2019-12-13.12df ............._- --------- _............__........_........... .._.... _ . Created by Independent Third Party: Yes ....... ...... ..._..__. 16708.5 E Design Pro /Smooth Pro /Studio Single with sidelite(s) (X,O/ O,X/ O,X,O) Impact Opaque Door Fiberglass 9-0 x 6-8 and 9-0 x 8-0 Inswing and Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16708 R13 II 16708.5 SS 2019-10-01.odf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. 73778 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports http://www.floridabuilding.org/pr/pr_app_dtl.aspx?parwn=wGEVXQwtDqu8obl%2flZm6TudWOg6cFUIGz%2bYuNViQ9olAo7zp34bbWg%3d%3d[12/16/20203:25:39 PM] Florida Buildinb Code Online Other: FL16708_R13_AE_PER4665.2 SS 2019-10-01.pdf Created by Independent Third Party: Yes 16708.6 F Design Pro / Smooth Pro Fiberglass Single with sidelite(s) (X,O/ O,X/ O,X,O) Impact Glazed Door 9- 0 x 6-8 and 9-0 x 8-0 Inswing and Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16708 R13 II 16708.6 SS 019-10-01.pdf Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Verified By: Hermes F. Norero, P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports Other: FL16708 R13 AEPERR4g4_ S 01 -1 - pdf Created by Independent Third Party: Yes 16708.7 G Design Pro / Smooth Pro / Studio Double with sidelite(s) (XX,O/ O,XX/ O,XX,O) Impact Opaque Fiberglass ---- ---. _ _... _ - -. Door 12-0 x 6-8 and 12-0 x 8-0 Inswing and Outswing ........... .__...... Limits of Use .... - - .. ..... ___. .....----- Installation Instructions Approved for use in HVHZ: Yes FL16708 R13 II D015708 - DP SP OPO LMI HVHZ OXXO XXO FBC SS 2019-12-12.12df Approved for use outside HVHZ: Yes Impact Resistant: Yes Verified By: Hermes F. Norero, P.E. 73778 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL16708 R13 AE PER4666 2 SS 2019-10-01 odf Created by Independent Third Party: Yes 16708.8 H Design Pro / Smooth Pro Fiberglass Double with sidelite(s) (XX,O/ O,XX/ O,XX,O) Impact Glazed Door 12-0 x 6-8 and 12-0 x 8-0 Inswing and Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16708 R13 II D015709 - DP SP GLZ LMI HVHZ OXXO XXO FBC SS 2019-12-12.pd Approved for use outside HVHZ: Yes Impact Resistant: Yes Verified By: Hermes F. Norero, P.E. 73778 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL16708 R13 AE P R4444. SS 2019-12-13,12df Created by Independent Third Party: Yes j The State of Florida Is an AA/EEO employer. Copyright 2007-201 Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address ifthey have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M ® eC;R Credit Card Safe http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV XQwtDqu8obl %2flZm6TudWOg6cFU 1 Gz%2bYuNViQ9ol Ao7zp34bbWg%3d%3d[l2/16/2020 3:25:39 PM] JE I-nrw.. EN WINDOWS & DOORS DESIGN PRO/SMOOTH PRO IMPACT APPROVED FOR USE IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ) GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT FLORIDA BUILDING CODE (FBC), INCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: • TAS 201-94 A TAS 202-94 • TAS 203.94 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY OR 2X FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION 15 THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. 4. APPROVED IMPACT PROTECTIVE SYSTEM-15 NOT REQUIRED ON THIS PRODUCT IN AREAS'REQUIRING IMPACT RESISTANCE. 5. 6-PANEL DOOR SHOWN FOR ILLUSTRATION PURPOSES. ADDITIONAL PANEL CONFIGURATIONS AND FLUSH DOORS ARE QUALIFIED. 6. NOTE: AFCO H-497 SILL MEETS WATER INFILTRATION AT WATER TEST PRESSURE (WTP) OF 9.75 PSF. REMAINING SILLS NOT RATED FOR WATER INFILTRATION. IF AUTHORITY HAVING JURISDICTION REQUIRES THAT PRODUCT MEETS THIS REQUIREMENT, PRODUCT SHALL BE USED WHEN INSTALLED AT LOCATION PROTECTED BY OVERHANG SUCH THAT OVERHANG (OH) RATIO = OH LENGTH :OH HEIGHT 15>: 1.0 TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION 1 A TYPICAL ELEVATIONS, DESIGN PRESSURES, AND GENERAL NOTES 2 A TYPICALANCHOR LAYOUTS AND NOTES 3 - OPTIONAL 2X BUCK ANCHORING DETAILS 4 A VERTICAL ASSEMBLIES 5 A HORIZONTAL ASSEMBLIES 6 A WOOD SUBSTRATES 7 A CONCRETE SUBSTRATES 8 A COMPONENTS& BILL OF MATERIALS 371/2" MAX. — 6 5 O.A. WIDTH 1 a 60 = 3 O n .z-, I lu 5 F 0 n (j 01 l7 °D Q d 3 z 4 s• B ACTIVE O w Z (7 3 Z O 0?1 2 [-� TYP. 3 a 5 6 i e 9 d a a a a a a ELEVATION 1 NOTE: DOORS SHOWN ABOVE MAY BE LEFT OR RIGHT HAND OPERATING DOORS. MAX. OVERALL NOMINAL SIZE DESIGN PRESSURE (PSF) MISSILE CONFIGURATION WIDTH HEIGHT INSWING OUTSWING IMPACT RATING POS. NEG. POS. I NEG. X 65• 65 65• 65 LMI&SMI X 50• 50 50• 50 LMI&SMI 'SEE GENERAL NOTE 6, SHEET 1, FOR WATER INFILTRATION APPROVED SILLS. PREPARED BY: ll� BUILDING DROPS, INC. 399 E. DANIA PEACH GYD., ML339 EMNIABEACH,Fl33 PN:195.p99dd70 —I..) ai39 WEB:—b.ftm dmpAmm � z a 'So a� 2q w Z r,LL�� EI) W m� n h ¢ 0 Z. Y L) w aLLJ LT1S� W OC a V) EA.3 c F d Atltl ADA 9111, MuIHAdntLxk GL O6/23/14 NeferenteppD10973A AM WA1119 off 'R STATE OF )Ig)tal)y signed 15; F%flnes F Norero leas-: I am approving this dooume )ate: 2019.10.01 21:21:16-D4'00' DATE: (}7_()5_JA SCALE: N 15 DWG. R: D015726 I INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 2. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 1/41NCH. SHIM WHERE SPACE OF 1/16INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. 3. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 4. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING, AND SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS. S. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 6. FOR 2X STUD CONSTRUCTION, ANCHORING OF THESE PRODUCTS SHALL BE THE SAME AS FOR 2X BUCK CONCRETE/MASONRY CONSTRUCTION. 7. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: A. WOOD- MINIMUM SPECIFIC GRAVITY OF 0.55. B. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. C. GROUT -FILLED CMU- UNIT STRENGTH CONFORMS TO ASTM C-90 WITH MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AND GROUT CONFORMS TO ASTM C 476, MINIMUM GROUT COMPRESSIVE STRENGTH OF 2000 PSI. 0. HOLLOW BLOCK CMU - UNIT STRENGTH CONFORMS TO ASTM C-90 WITH MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI. . .. B- ..SEEESHEETSfiAND7.FOR.MQREDETALLSQETHE_INSTALLAILQt REQU1REM.ENTS, lN..NCHOR_ .. _. .... _ .. _._ ... ... LOCATIONS, EDGE DISTANCES, EMBED MENTS, AND SHIM SPACING. 9. OPTIONALLY, ANCHORS CAN BE PLACED IN NARROW SECTION OF HEAD OR JAMS AS LONG AS MINIMUM EMBEDMENT AND EDGE DISTANCE ARE ACHIEVED. ANCHORTABLE 6'8" DOORS 8'0" DOORS ANCHOR TYPE ANCHOR 812E SUBSTRATE MIN. EMBEDMENT MIN.EDGE DISTANCE MAX.O.0 MAX. O.C. SPACING AT SPACING AT JAMBS JAMBS WOOD SCREW If10 2X WOOD BUCK 1.1/2' 3/4" 17.1/2' 17-1/4" OR FRAMING ITW TAPCON 3/16" CONCRETE/CMU 1.1/4' 2-1/2" 17.1/2' 17-1/4" ELCO ULTRACON 1/4" CONCRETE/CMU 1-3/8"-CONC. 1' 17-1/2" 1-1/4" - CMU ITWTAPCON 3/16' CONCRETE/CMU 1-114" 1' 10" 14-3/8" B2 2. 49 X 212' PFH PFH SCREWS DETAIL B2 TYP. HOPPE 1-BOTTOM SH007 MULTI -POINT SHOOT BOLT BUT PLATE PLATE LOCATION HOPPE 42D98911 q SILLSECTIONVIEW �NiWL i_lC.DUISWINGSIMIAX 2- #9 X 21/2' PFH SCREWS DETAIL D2 22 23 TYP. HOPPE MULTI -POINT SHOOT BOLT PLATE LOCATION (RH PLATE SHOWN) 02 HEAD SECTION VIEW 112" MAX. �TYP.ANCHOR LAYOUT i'-9' 8 f-0' f100R NDGM NOTE: NO ANCHORS REQUIRED AT THE SILL FOR SINGLE DOORS (X) ONLY. PREPARED BY: BUILDING DROPS, INC. J98 E. DANU A. BLVD., SfF. A9 P.: ORF fl)390f PR: (%99<)30a99ddta fAR: I9u1>wn»e wee: w. b."dmsd'.f . VI O Z >$ O mono a 0 0 F=-4'' �p Z Q W LL�u4 s � O y � iL mY O� a a 0 g ZY O V � Z Q p't J a_ a EL w; EL REMARKS IMF tdd ADA sIU. MultiPoint Lock GL 6123 Reference DWG. NA010871A AM /lE ,``IIII11 II11 f/JJJ % 0 J'Ji o E S Pp �* N .77 S A -OF C ra�i.f t �Dxtio".cDne fn DATE: 02.05.14 GL/TJM S5,' MsS SCALE: NTS DWG.#: D015726 SHEET: OF S 2 11 INTERIOR DMOR �1 OPERABLE HEAD 4 OUTSWING SHOWN _ INSWING SIMILAR INTERIOR EXTERIOR 10 OPERABLE ADA SILL_ 4 INSWING/OUTSWING ENDURA HC15000 11 8 INTERIOR EXTERIOR o g OPERABLE SILL OUTSWING 0 ' r h II r. •TT � I 3� OPERABLE SILL 4 INSWING OPERABLE SILL (I, INSWING (]) OPERABLE SILL 4 OUTSWING 11 S INTERIOR ./ EXTERIOR n OPERABLE SILL 4 OUTSWING 11 7 INTERIOR E MIOR :J o Twvf. M OPERABLE SILL 4 OUTSWING OPTIONAL AFCO H-497 PREPARED RY: BUILDING DROPS, INC. 398 E OANIA pUCN BWD. pTF.IIB oaHu peas, itBYOa PM: 19p11394M)p eIJf: I95417KA138 W FB: wYrr. W IldyyEm 0� mm O mod a � ohmm O'o Do g a s W Ln mY Oti aQ Ln Q U K W > + S C a r 'Add ADANI,MuIti*p"" C' IAM D9/GLrlil7JB46J19' Reference DWG..A010R7. S o 5 A OF Q :'D4. O�c�` r iCuy➢:" +nlaAi DATE: 02.05.14 GLtTJM SS�MSS SCALE: NTS DwG.N: D015726 SHEET: OF S 4 INTERIOR —8 - 89 X 21/2" PFH EXTERIOR W/ STRIKE HARDWARE 4- MPL STRIKE PLATES n LOCK JAMB Si OUTSWING SHOWN - INSWING SIMILAR 9 -R9 X 13/4° PFH 8-#9X 21/2"PFH W/HARDWARE W/STRIKEHARDWARE (6'-8"&8'-0"UNITS) 4- MPL STRIKE PLATES EXTERIOR INTERIOR 4 MULTI -POINT LOCK JAMB 5 OUTSWING SHOWN -INSWING SIMILAR HINGE SCHEDULE DOOR HEIGHT QUANTITY 6'-8" 3 8'-0.. 4 HINGE DETAIL ATJAMB: PLACE N9 X 2-112" PFH SCREW NEXT TO WEATHERSTRIP INTERIOR\�• / �O I- H9 X 2-1/2" PHILLIPS FLATHEAD WOOD SCREW \' 3- R9 X 3/4" PHILLIPS EXTERIO FLATHEAD WOOD SCREWS 4 q9 PHILLIPS FLATHEAD WOOD SCREWS 17 USE 3/4" LENGTH FOR 6'-8" DOORS USE 1" LENGTH FOR 8'-0" DOORS 3 HINGE JAMB 5 OUTSWING SHOWN - INSWING SIMILAR 13. #8 X 13/8° PFH (G'-8" UNITS) 3-$18X 2°PFH r15-88X13/8"PFH(8'-0"UNITS) W/STRIKEHARDWARE COMES W/HARDWARE 1- MPL STRIKE PLATE EXTERIOR c "'�INTERIOR MULTI -POINT LOCK JAMB 5 OUTSWING SHOWN -INSWING SIMILAR 4 - N8 X 13/8' PFH 1- REINFORCEMENT PLATE HOPPE H2512296 J6---� MULTI -POINT LOCK 5 TOP REINFORCEMENT PLATE- ACTIVE PANEL ONLY PREPARED BY: BUILDING DROPS, INC. 399E. PANW BEACH BEw-Sa[ M DANIABEACH.FL3ROD3 FN:195aIJ54Bl]8 FAY: (9511>YAJ38 WEB: ww•r.E"ad'n9sft- a ai O w m O °md C O Z W EDLu u�LL.x a Otr to m� i �Q O ti Q mY 0 W� N O 0 � �z 1.4 Wa REMARKS JBYJ DA1 Ldd ADA sill, Multi -Point LDd GL 6/1: Reference DING.0A010871A AM VIF eneooi��mii�D�zev�"mnoEo unitai �us ?* .• N .7 7 :v SA OF 5 7� XL i pT i�i oP •' w ' A.sxf�wip�',B�yAgq�riff\ ��; e�/RJ r IADKxo, nlieN DATE: 02.05.14 DWG. Y: CHK. Y: GL%TJM SS/MSS SCALE: NTS DWG. R: D01S726 SHEET: OF 8 5 PREPARED BY: 2X WOOD BUCK Q BUILDING DROPS, INC. 398E MIN. MMBEACN,R3lOPR 336 EDGE DIST. z `9 % WOOD ANCHOR N I96Q—.1. SEE TABLE SHEET �Wa / SEE TABLE ON SHEET E"R:19saP�a.m3s N WFB: w.I—)744.V Ptcom SILICONE W w 2X WOOD BUCK .o cc 0 m m $ �w a °Jma o N MAX. WOOD BUCK O cr Q m aVT.- 2XANCHOR SHIM N a F n x SEE TABLE ON SHEET 2 MIN. EMBED. �¢ N SEE TABLE SHEET ¢ ¢ DO zx Ln HEAD (TYPICAL) [� JAMB (TYPICAL) WI� OPERABLE SILL o W 6 OUTSWING SHOWN - INSWING SIMILAR OUTSWING SHOWN - INSWING SIMILAR INSWING - NO ANCHOR REQUIRED O O SILICONE ^ SILICONE SILICONE �7 H 2X WOOD BUCK 2X WOOD BUCK REMARKS BYJ DATE Add ADA n31,MWtFPoint Lock Gl 6R3/14 Reference DWG. NADIO871A AM 9/16 19 2X WOOD BUCK . D D vql nor Ru armEaroRASPEDe OPERABLE SILL n OPERABLE SILL rTOPERABLE SILL DfN9m D" rONBCAUSEIMP 4EL NY �OIDBVMIE iROMTIi 4pnR[MfRR D'AIfED NFREDt q rKENSFO fNGIMEROR RgW�rFCTBN LLfIIEeARF Sf[SeE[6K 6 OUTSWING- NO ANCHOR REQUIRED J INSWING- NO ANCHOR REQUIRED 6 OUTSWING- NO ANCHOR REQUIRED �E``�111�LIfi/J2jMrM �v AFCO H-497 �� .� .. O -1i1110 N 7 7 O b S A OF !r o SILICONE SILICONE SILICONE :BOEC�. q Mn Or}➢Tm 2X WOOD BUCK 2X WOOD BUCK 2X W00D BUCK DATE: 02.05.14 DWG.BY:CHK. Y: OPERABLE SILL � OPERABLE SILL � OPERABLE ADA SILL GLT.lM SS/MSS 6 OUTSWING- NO ANCHOR REQUIRED 6 OUTSWING- NO ANCHOR REQUIRED 6 INSWING/OUTSWING- NO ANCHOR REQUIRED SCALE: NT5 DWG.0: D015726 SHEET: OF8 OPTIONALLY, ANCHOR CAN BE PLACED IN NARROW /` SECTION OF HEAD OR JAMB AS LONG AS MINIMUM Vh EMBEDMENT AND EDGE DISTANCE ARE ACHIEVED. MIN. EDGE DIST. SEE TABLE SHEET 2 wN CONCRETEi L MASONRY :j_- BY OTHERS WOOD BUCK (OPTIONAL) \—CONCRETE ANCHOR SEE TABLE ON SHEET 2 HEAD (TYPICAL) OUTSWING SHOWN - INSWING SIMILAR A 4 C 77.!ONCRETE/ Y MASONRY BY OTHERS (4) OPERABLE SILL \J OU­fSWING - NO ANCHOR REQUIRED SILICONE . :7: o 'd CONCRETE/ MASONRY BY OTHERS OPERABLE SILL 7-J OUTSWING - NO ANCHOR REQUIRED OPTIONALLY, ANCHOR CAN BE PLACED IN NARROW SECTION OF HEAD OR JAMB AS LONG AS MINIMUM EMBEDMENT AND EDGE DISTANCE ARE ACHIEVED. PREPARED BY: 1XWOOD BUCK IQ� (OPTIONAL) BUILDING DROPS, INC. DAMA MBEACR EJJB mow ACK Ft I —A CONCRETE ANCHOR SILICONE J�- SEETABLE ON SHEET2 FAX:j­)744AM CONCRETE/ MASONRY E> BY OTHERS 0.25" MAX. SHIM CONCRETE/MASONRY BY OTHERS MIN. EMBED. a 0 SEE TABLE SHEET 2 'n R, ' 4 JAMB (TYPICAL) OPERABLE SILL F_ OUTSWING SHOWN - INSWING SIMILAR INSWING -NO ANCHOR REQUIRED p u z SILICONE SILICONE REMARKS BY DATE i,t Lack 06123 tI. Multl�­t O AddADAsi GL Re CONCRETE/ CONCRETE/ Refer— DWG. PA010871A AM 09116A MASONRY MASONRY BY OTHERS BY OTHERS (-6-OPERABLE SILL \IV INSWING - NO ANCHOR REQUIRED SILICONE a. CONCRETE/ MASONRY BY OTHERS OPERABLE SILL 7-J OUTSWING- NO ANCHOR REQUIRED OPERABLE SILL OUTSWING - NO ANCHOR REQUIRED AFCO H-497 SILICONE 4 a. '--CONCRETE/ MASONRY BY OTHERS /M OPERABLE SILL Z'/bUTSWING/INSWING - NO ANCHOR REQUIRED I I fill,, 7 OF Flir :.Jj DATE: 02.05.14 DWG HK. BY: G Llb F M I SS MSS SCALE: NTS DWG.#: D015726 SHEET: OF 7 BILL OF MATERIALS ITEM# DESCRIPTION MATERIAL 1 FRAME HEAD/JAMBS FINGER -JOINTED PINE SOLID PINE LAMINATED VENEER LUMBER COMPOSITE 2 (NOT USED) 3 (NOT USED) 4 THRESHOLD •- 5 THRESHOLD - 6 THRESHOLD - 7 AFCO H-497 THRESHOLD - 8 THRESHOLD - 9 THRESHOLD - 10 ADA THRESHOLD - 11 WEATHERSTRIP URETHANE FOAM & POLYETHYLENE 12 NON -COMPRESSION SHIM (0.25"MAX THY) COMPOSITE 13 (NOT USED) - 14 (NOT USED) - 15 #10 WOOD INSTALLATION SCREW W/ 11/2- MIN. EMBEDMENT STEEL 16 CONC./CMU ANCHOR (SEE ANCHOR TABLE SHEETS 2 & 3) STEEL 17 BUTT HINGE (SEE SCHEDULE SHEET 5) STEEL 18 LOCK SERIES 400 STEEL 19 DEADBOLT SERIES 780 STEEL 20 ROCKWELL MULTI -POINT TONGUE LATCH It73228768 6-8 UNIT ROCKWELL MULTI -POINT TONGUE LATCH #732287808-O UNIT STEEL 21 HOPPE MULI-POINT HARDWARE HLS9DD0 STEEL 22 HOPPE MULI-POINT HEAD SHOOT BOLT PLATE LH#8784091 STEEL 23 HOPPE MULI-POINT HEAD SHOOT BOLT PLATE RH#8783923 STEEL OFRAME HEAD/JAMBS VARIES, SEE BOM AT LEFT ///"i/ .. 1 (— 4563" --{ 20 ROCKWELL MULT—POINT LOCK O O a O c? q CZD 13 Y o p 21 HOPPE MULT—POINT LOCK W/ SILL SHOOT BOLT PLATE 42098911 PREPARED BY: BUILDING DROP5, INC. 393 E. DANIA BE— BLV ,SM 338 DANIADEADI, R33ro1 eN:lsul3ssaas8 FAE:Is611)u nse WEB: ruw.OWWNE�Pamm En J < Oy ~ O C 14J Q Fo^g, a o�Pm 12 T 1- LL Yds—� 0 p U- Oq O M!Fc` 2 ¢ Z ^c W N O E• ZLLI ° y� cZ 0 I- V REMARKS BY DXAdtl ADA 1111, Multl-Poi"[ luck GL 6/2: Reference OWG. NA010871A AM 09fl, IEC -4 1.6o5" I--1 S A O THRESHOLD O THRESHOLD O THRESHOLD 22 HEAD SHOOT BOLT PLATE (LH) �:�C)'��+ Fg i) F rBrl� B � C� I i II 4.56' --{ f 6.62° -I 4.57' 1 1.75° DATE: 02,05, 7 AFCO H-497 THRESHOLD O OF DWG. Y: CHK. Y: THRESHOLD O THRESHOLD O THRESHOLD ADA O HEAD SHOOT BOLT PLATE (RH) G L TJM SS/MSS 9 10 23 SCALE: NTS I o , DING. #: D015726 SHEET: OF8 5.00° LJ S 4.56" 0 1.75" BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Prof -duct E7 ahuation Re -port of JELD-WEN, inc. Design Pro / Smooth Pro Opaque (Impact) (HVHZ) for Florida Product Approval e,nort No. 465-3, 398 E. Dania Beach Blvd. Suite 338 Dania Beach, Fl- 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Current Florida Building Code Method: 1- D (Engineering Method) Category: Exterior Door Assemblies Sub - Category: Swinging Exterior Door Assemblies Product: Design Pro/ Smooth Pro Material: Fiberglass Product Dimensions: 3'-0" W x 6'-8" H (Nominal) 3'-0" W x 8'-0" H (Nominal) Prepared for: 3ELD-WEN, ins. (( 3737' Lr, ��epeo+�Blvd. '1R Prepared by: .Hermes F. Norera, P.E. Florida Professional Engineer # 73778 Date:09/13/2019 Contents: Evaluation Report Pages 1— 4 Digitally signed by Hermes F Norero Reason: I am approving this document Date: 2019.10.01 21:18:24-04'00' : N 7 7 0 w OF O HerF NotAA6, P.E. Florida No. 73778 BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Manufacturer: Product Category: Product Sub -Category: Compliance Method: Product Name: JELD-WEN, inc. Exterior Door Swinging Exterior Door Assemblies State Product Approval Method (1)(d) Design Pro / Smooth Pro Opaque (Impact) (HVHZ). 3'-0" X 6'-8" (Nominal) 3'-0" X 8'-0" (Nominal) Date: 09/13/2019 Report No: 4663.2 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD-WEN, inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions provided by manufacturer for specific use parameters. 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering for Wind Zone 3. 4. Site conditions that deviate from the details of manufacturer require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions for size and design pressure limitations Hermes F Norero, P.E. Florida No.73778 Page 2 of 4 BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Date: 09/13/2019 Report No: 4663.2 Certification Agency: The manufacturer has demonstrated compliance of door products in accordance with the current Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization #: CER1773) Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization # TST1589) Report # Report Date: NCTL-210-3916-01 08/30/13 NCTL-210-3925-03 02/07/14 NCTL-210-3916-02 w/ addendum 06/10/14 NCTL-210-3930-01 02/24/14 NCTL-210-3930-02 03/10/14 TAS Report Engineer of Record: Gerard J. Ferrara, P.E. Report # Report Date: SJW2013-194 w/ addendum 06/10/14 TAS Report Engineer of Record: Kevin P. Tyra, P.E. Report # Report Date: SJW2013-196-TAS 09/13/13 SJW2013-246 12/17/13 SJW2013-251 12/23/13 SJW2013-252 12/23/13 SJ W 2013-253 12/23/13 SJ W 2014-032 04/22/14 SJW2014-073 06/26/14 SJ W 2014-077 06/27/14 SJ W 2014-072 06/27/ 14 SJW2014-080 07/03/14 TAS Report Engineer of Record: Robert H. Zeiders, P.E. 2. Quality Assurance Entity National Accreditation & Management Institute (FBC Organization #QUA1789) Hermes F Norero, P.E. Florida No.73778 Page 3 of 4 BUILDING DROPS A Perfect Solution in Every Dropl Certificate of Authorization: 29578 Date: 09/13/2019 Report No: 4663.2 Component Material Testing of Dylite Expandable Polystyrene by Intertek Testing Services NA, Inc. ASTM E84 Report#: 3113726SAT-001 R1 Report Date: 03/13/09 4. Component Material Testing of Fiberglass SMC Skin Element Materials Technology ASTM D635, ASTM D638, ASTM D1929, ASTM D2843, ASTM G155 Report#: ESP010982P Report Date: 02/26/13 Installation: Refer to Installation Instructions (D015726) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to drawing (D015726) for pressure information. Hermes F Norero, P.E. Florida No.73778 Page 4 of 4