Loading...
HomeMy WebLinkAboutProduct Approval; Single Hung WindowsFlorida Building Code Online Page 1 of 3 BCIS Home ? Log In User Registration Hot Topics Submit Surcharge Stats &Facts Publications Contact Us gip Varch Product Approval USER: Public User wr -s Product Approval Meru > Product or Aoalication Sear[h > Application list > Application Detail REVIE®��yrry1 F on i FL # FL14095-RII CODE COMPLIANCE Application Type Code Version Affirmation 2020 Y ����� COUNTY ST. Application. Status Approved `BOCC%! C� 14 Comments Archived Product Manufacturer JELD-WEN Address/Phone/Email 3737 Lakeport Blvd Klamath Falls, OR 97601 (800) 535-3936 fbcl@jeld-wen.com Authorized Signature Rylee Sumner Fricks fbcl@jeld-wen.com Technical Representative JELD-WEN Corporate Customer Service Address/Phone/Email 3737 Lakeport Blvd. Klamath Falls, OR 97601 (800) 535-3936 customerserviceagents@jeld-wen.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity 0 Yes w No O N/A Product Approval Method Method 1 Option A https://www.floridabuilding. org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtGLR%2byCB... 9/ 14/2021 Florida Building Code Online Page 2 of 3 Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products 07/29/2020 07/29/2020 07/31/2020 FL # Model, Number or Name Description 14095.1 Premium Atlantic Vinyl Single Hung (8100) 36" x 72" Insulated Glass (5/16 in PVB or SGP Lam - 1/8 out Annealed ) Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14095 R11 C CAC NI011567.04-R3.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 04/30/2025 Design Pressure: +65/-70 Installation Instructions Other: Laminated glazing interlayer material requirements FL14095R11II FL14095 R5 II DP65- meet the current edition of the FBC in accordance with Miami- 70 3602 Impact Installation Instructions.adf Dade NOA for DuPont SentryGlas and DuPont PVB interlayers. FL14095 Rll II NI011567.04-R3 Dwgs 07252017.odf Verified By: Hermes Norero, PE 73778 White PVC exterior extrusion meet the current edition of the FBC in accordance with Miami -Dade NOA for Quanex. IG back Created by Independent Third Party: Yes bedded with Dow 995. Safety glazing required to the exterior Evaluation Reports at heights above 30 feet. FL14095 R11 AE PER3094.pdf Created by Independent Third Party: Yes 14095.2 Premium Atlantic Vinyl Single Hung (8100) 36" x 72" Insulated Glass (1/8 in - 1/8 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14095 R11. C CAC NI01.1567.08-R.l.pdf Approved for use outside HVHZ: Yes FL14095 R11 C CAC NI011567.09-R2.odf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +65/-70 04/30/2025 Other: White PVC exterior extrusion meet the current Installation Instructions edition of the FBC in accordance with Miami -Dade NOA for FL14095 Rll II N1011567.09-R2 Dwgs 07252017.pdf HL1 E:095.,_R11,,._II,__P1V..::%SH,._FC. 36x2,_S5,_201_/,-06, 26,;,pdf Quanex. IG back bedded with Dow 995. Safety glazing required to the exterior at heights above 30 feet. Verified By: Hermes Norero, PE 73778 Created by Independent Third Party: Yes Evaluation Reports FL14095 R11 AE PER4869 SS 2017-06-26.odf Created by Independent Third Party: Yes 14095.3 Premium Atlantic Vinyl Single Hung (8100) 52 1/8" x 75" Insulated Glass (3/16 in - 3/16 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14095 Rli C. CAC NI011567.06-Rl.odf Approved for use outside HVHZ: Yes FL14095 Rii C CAC NI011567.07-R2.pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +65/-70 04/30/2025 Other: White PVC exterior extrusion meet the current Installation Instructions edition of the FBC in accordance with Miami -Dade NOA for FL14095 R11 H NI011567.07-R2 Dwgs 07252017.odf F17:09,__R],1__II._PAV..TSH FI3C 52x75 SS 201:7-06.2G,pcif Quanex. IG back bedded with Dow 995. Windows with insulated glass wider than 36" require setting blocks. Safety Verified By: Hermes Norero, PE 73778 glazing required to the exterior at heights above 30 feet. Created by Independent Third Party: Yes Evaluation Reports FLIA095 Ril_AE .PER4.8/0 55,_2017,-06-26,pdf Created by Independent Third Party: Yes 14095.4 J 1 Premium Atlantic Vinyl im' f Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-60 Other: Laminated glazing interlayer material requirements meet the current edition of the FBC in accordance with Miami - Dade NOA for DuPont SentryGlas and DuPont PVB interlayers. White PVC exterior extrusion meet the current edition of the FBC in accordance with Miami -Dade NOA for Quanex. IG back bedded with Dow 995. Windows with insulated glass wider than 36" require setting blocks. Safety glazing required to the exterior at heights above 30 feet. Single Hung (8100) 52 1/8" x 75" Insulated Glass (5/16 in PVB or SGP Lam - 1/8 out Annealed) Certification Agency Certificate FL14095 R11 C CAC NI011567.02-112.odf Quality Assurance Contract Expiration Date 04/30/2025 Installation Instructions FL14095 Rll II FL1.4095 R5 lI DP50- 60 52125x75 Impact Installation Instructions.pdf FL14095 R11 1I NI011567.02-R2 Dwos 07252017.odf Verified By: Hermes Norero, PE 73778 Created by Independent Third Party: Yes Evaluation Reports FL14095 R11 AE PER3091.ndf Created by Independent Third Party: Yes 14095.5 I Premium Atlantic Vinyl Single Hung (8100) 52 1/8" x 75" Insulated Glass (5/16 in SGP Lam - 3/16 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14095 Rii C CAC NI011567.01-Rl.odf Approved for use outside HVHZ: Yes EUA.,095_,_Ili_i..._C,,,_C8C„_Ni0115C _11I_pdf Impact Resistant: Yes Quality Assurance Contract Expiration Date https: //www.floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQ WtDgtGLR%2byCB ... 9/ 14/2021 Florida Building Code Online Page 3 of 3 Design Pressure: +65/-75 Other: Laminated glazing interlayer material requirements . meet the current edition of the FBC in accordance with Miami - Dade NOA for DuPont SentryGlas and DuPont PVB interlayers. White PVC exterior extrusion meet the current edition of the FBC in accordance with Miami -Dade NOA for Quanex. IG back bedded with Dow 995. Windows with insulated glass wider than 36" require setting blocks. Safety glazing required to the exterior at heights above 30 feet. 04/30/2025 Installation Instructions FL14095 R11 11 FL14095 R5 11 DP65- 75 52.125x75 Impact installation Instructions,ndf FL14095 R11 II NI011567.01-R1 Dwgs 07252017.pdf Verified By: Hermes Norero, PE 73778 Created by Independent Third Party: Yes Evaluation Reports FL14095 R11 AE PER3095.odf Created by Independent Third Party: Yes Baci - Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: MW9MEIM Credit• Safe .�Cltrit�rr�t>e'r�1.eN�, https://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtGLR%2byCB... 9/ 14/2021 I NIDSPAN A 157V 0.0. W1L n= NAL FlN p� LS NAIL co;M �woom %Wffl Qu 1/E• TYPICAL ELEVATION WITH FASTENER 5PACIN6 Installation Notes: 1. Seal flange/frame to substrate. 2. Use #10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 1/2" into the wood framing. For 2X wood frame substrate (min. S.G. = 0.42). 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date: 2014.09.1916:25:32-04'00' This schedule addresses only the fasteners required to anchor the I I I window to achieve the rated design pressure up to the size limitations ����� noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall ��� �� •.•''' •• •' • < conditions. For the complete installation procedure, see the instructions packaged with the window or go to 7 www.jeld-wen.com/resources/installation. DISCLAIMER: T T ••'•. This drawing and its contents are confidential and are not to be reproduced or copied in whole or in part or used or disclosed to others .0 O ���pXN except as authorized by JELD-WEN Inc. age g°9e eea 11/2' MIN. EMBEDMENT 2 2X WOOD FRAME i DISTANCE -1MIN. 7 FOR EDGE: 3/4' 1/4' MAX 3 J SHIM SPACE 2mm 2mm 3mm r4 3mm GLASS 13it m f GLAZING DETAIL 1 FRAME SECTION (TYP) 1 VERTICAL SECTION w11e —IWIu Fkdr&W dOpwy 1/4" MAX SHIM SPACE 3 MIN. DISTANCE FOR EDGE: 3/4' 2 2X WOOD FRAME 11/2' MIX EMBEDMENT 338 NAIL FIN INSTALLATION JAMS SECTION (TYP) HORIZONTAL SECTION NOTE: Caulk between Nailing flange 6 Wood Openi,g. PREMIUM ATLANTIC VINYL SH WINDOW Max Frame I DP RATING IMPACT 52 1/8 x 75 1 +50/-60 1 YES LARGE MISSILE IMPACT General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida Building Code (FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM E1300. 3. At minimum, glazing is 3mm annealed -11mm airspace - 3mm annealed - 2mm PVB Intedayer by DuPont - 3mm annealed. 4. Use structural or composite shims where required. PROJECT ENGINEER: DATE: -- 08/13/2014 JELDAWEN 3737 Lakeport Blvd DRAWN BY: SCALE: Klamath Falls, OR. 97601 D. Vezo NTS Phone: (541) 882-3451 CHECKED BY: J. Kantola APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window No. IREV: 00 ISHEET 1 OF3 14111O JAMS 5X YA% ----- FROY COR = lox YAtTI= Jlmll AYD MAIL r eoRlFs:s Pcomma �W= W WIDIN (52 IN I %)_ I TYPICAL ELEVATION WITH FASTENER SPACING Installation Notes: 1. Seal flange/frame to substrate. 2. Use 3/16" ITW Tapcon or equivalent fasteners through frame with sufficient length to penetrate a minimum of 1 1/4" into concrete or masonry at each location with a 21/2" min from edge distance. For concrete (min. fc = 3000psi) or masonry substrate (CMU shall adhere to ASTM C90). 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall conditions. For the complete installation procedure, see the instructions .; packaged with the window or go to www.jeld-wen.com/resourcesfinstallaton. DISCLAIMER: This drawing and its contents are confidential and are not to be reproduced or copied in whole or in part or used or disclosed to others except as authorized by JELD-WEN Inc. BOB a( 44%%J%J1IC'RI,, MIN. DISTANCE FOR EDGE: 21/2• FMASONRY e oaI z e 3 1 w• Mat EMBEDMENT 1/4° MAX SHIM SPACE 2mm xmm 3mm 3mm alb GLAZING DETAIL FRAME SECTION (TYP) VERTICAL SECTION wrE: mn � wiu. w.w a "c.e a,.aq vA• MAX SHIM SPACE a d • ,® .. 1 vA• Mat EMBEDMENT q •. 2 MASONRY BLOCK MIN. DISTANCE FOR EDGE: 21/2• MASONRY INSTALLATION i 11/4• MIN. EMBEDMENT 1/4• MAX Q 3 SHIM SPACE MIN. DISTANCE . 0 a FOR EDGE: 21/2° d Q V a• . •v • 1v MASONRY BLOCK JAMB SECTION (TYP) HORIZONTAL SECTION I PREMIUM ATLANTIC VINYL SH WINDOW Max Frame I DP RATING IMPACT 52 1/8 x 75 1 +50/-60 1 YES LARGE MISSILE IMPACT General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida Building Code (FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM E1300. 3. At minimum, glazing is 3mm annealed -11 mm airspace - 3mm annealed - 2mm PVB Interlayer by DuPont - 3mm annealed. 4. Use structural or composite shims where required. 7j PRWECTENGINEER: DRAWN BY: D. Vezo fo.. J Kantola APPROVED BY: `` 410FF�1li), PLJT�PVO�/ L9 PEAd6h .%%Ate 938 IDENTIFIER No. -- DATE: 3737 Lakeport Blvd 08/13/2014 JELDNENKlamathSCALE: Falls, OR. 97601 NTS Phone: (541) 882-3451 TITLE: Premium Atlantic Vinyl Impact Single Hung Window DWG. No.: I REV. 00 I SHEET 20F3 THOU Jim FROM CORl1ER5 j Afv leA• HRU Aux. t►Qu J" ie S CORNM LWn11EB j�WINWW WM (R 1/a• W7L)---� TYPICAL ELEVATION WITH FASTENER SPACING Installation Notes: 1. Seal flangetframe to substrate. 2. For anchoring into metal framing use #8 TEK Self Tapping screws with sufficient length to achieve a minimum embedment of three threads past the frame thickness. Steel substrate min.18ga., fy = 33 ksi. 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall Q` .•'``�• " conditions. For the complete installation procedure, see the instructions packaged with the window or go to 7 www.jeld-wen.com/resourcesAnstallation. DISCLAIMER: :• T T This drawing and its contents are confidential and are not to be '•.• Cp OQ'.� �I'le� reproduced or copied in whole or in part or used or disclosed to others except as authorized by JELD-WEN Inc. p x b sea MIN. DISTANCE FOR ED6E:1/2° Mia embedment of three threads past frame FRAME SECTION (TYP) VERTICAL SECTION NOTE. CWRbels Nam Fav a Woos opuse Min. embedment of three threads post frame MIN. DISTANCE FOR EDGE:1/2" STEEL INSTALLATION 18 gauge min Steel Stud 1/4" MAX SHIM SPACE MIN. DISTANCE 2 FOR EDGE: 1/2" Min. embedment of three threads 3 past frame 1 JAMB SECTION (TYP) HORIZONTAL SECTION PREMIUM ATLANTIC VINYL SH WINDOW Max Frame I DP RATING IMPACT 52 1/8 x 75 1 +50/-60 1 YES LARGE MISSILE IMPACT General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC),, the International Residential Code(IRC), the Florida Building Code (FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM E1300. 3. At minimum, glazing is 3mm annealed -11 mm airspace - 3mm annealed - 2mm PVB Interlayer by DuPont - 3mm annealed. 4. Use structural or composite shims where required. PROJECT ENGINEER: j DRAWN BY: D. Vezo .y, CHECKED BY: )C _ ]. Kantola X APPROVED BY: �` P�Tbpbm��i9 Ito SSa IDENTIFIER No. NCTL210-3874- 3737 keport Blvd i/2014 1 JEL ��N Klamath Falls,(5OR. 97601 ) 82-3451 NTS Premium Atlantic Vinyl Impact Single Hung Window AND LOCATION: I CAD DWG. No.: I REV. 001 SHEET 3 OF 3 ntom CORIERS 1B3' O.C. YA � J B p� C MAX FROM i10co mm �--ram WOM (521/r MAXI TYPICAL ELEVATION WITH FASTENER SPACING Installation Notes: 1. Seal flange/frame to substrate. 2. Use #10 PH or greater fastener though the jamb with sufficient length to penetrate a minimum of 1 1 /2" into the wood framing. For 2X wood frame substrate (min. S.G. = 0.42). 3. Host structure (woad buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. Addendum to NAMI Certification No: NIO11567.02-R2 Reviewed By: This schedule addresses only the fasteners required to anchor the Date Reviewed: 07/25/2017 window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall conditions. For the complete installation procedure, see the instructions packaged with the window or go to www.jeld-wen.com/resourcesfiinstallaton. DISCLAIMER: This drawing and its contents are confidential and are not to be reproduced or copied in whole or in part or used or disclosed to others except as authorized by JELD-WEN Inc. MIN. DISTANCE FOR EDGE: 3/4" 3 11/2' MIN. EMBEDMENT MAX SK SHIM SPACE 2mm 2mm 3mm 3mm GLASS BITE 13. mm r GLAZING DETAIL FRAME SECTION (TYP) VERTICAL SECTION NOTS( kE"Aroi Wv ,Fkm &Wood Op.&4 v4" MAX SHIM SPACE 3 11/2" MIN. EMBEDMENT MIN.DISTANCE FOR EDGE: 3/4' THROUGH FRAME INSTALLATION 11/2" MIN. EMBEDMENT 1/4" MAX SHIM SPACE 3 MIN. DISTANCE FOR EDGE: 3/4" ,Z 1 JAMB SECTION (TYP) HORIZONTAL SECTION PREMIUM ATLANTIC VINYL SH WINDOW Max Frame I DP RATINGI IMPACT 52 1/8 x 75 +50/-60 YES LARGE MISSILE IMPACT General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida Building Code (FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM E1300. 3. At minimum, glazing is 3mm annealed -11mm airspace - 3mm annealed - 2mm PVB Intedayer by DuPont - 3mm annealed. 4. Use structural or composite shims where required. PROJECT ENGINEER: DATE: 08/13]3] Lakeport Blvd 3/2014 DRAWN BY: SCALE: Klamath Falls, OR. 97601 D. Vezo NTS Phone: (800) 535-3936 CHKKED BY: J. Kantola APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window N IDENTIFIER TL2IO-38%4-J! FBC�E AND LOCATION: I CAD DWG. No.: I REV. oo I SHEET 1OF1