HomeMy WebLinkAboutProduct Evaluation Report; Horizontal Slider WindowsBUILDING DROPS
A Perfect Solution in Every Drop
-- -- Certificate of Authorization: 29578
Of
JELD-WEN, inc.
398 E. Dania Beach Blvd.
Suite 338
Dania Beach, FL 33004
954.399.8478 PH
954.744.4738 FX
contact@buildingdrops.com
Premium Atlantic Vinyl 8200 Horizontal Sliding Window
for
Florida Product- Approval
Current Florida Building Code
Method:
Category:
Sub — Category:
Product:
Material:
Product Dimensions:
1— A (Certificate)
Windows
Horizontal Slider
Premium Atlantic Vinyl 8200 Horizontal
Sliding
PVC
74" x 54" (XO)
Prepared For:
. E .. - EN', inc.
3737 Lakeport Blvd.
•d.
Klamath Falls, OR 97601.
Prepared by:
Hermes F. Norero,.P.E.
Florida Professional Engineer # 73778
Date: 05/12/2015
Contents:
Evaluation Report Pages 1 — 4
Digitally signed by Hermes F. Norero, P.E.
Reason: I am approving this document
Date: 2015.05.13 11:44:32-04'00'
Hermes F. Norero, P.E.
Florida No. 73778
BUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29579
Manufacturer:
Product Category:
Product Sub -Category:
Compliance Method:
JELD-WEN, inc.
Windows
Horizontal Slider
State Product Approval Method (1)(a)
Product Name: Premium Atlantic Vinyl 8200 Horizontal Sliding Window
(Impact)
74" x 54" (XO)
Date: 05/12/2015
Report No: 3101
Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD-WEN, inc.
based on Method 1a of the State of Florida Product Approval, Florida Department of Business and
Professional Regulation - Florida Building Commission.
Limits of Use:
Hermes F. Norero, P.E. does not have nor will acquire financial. interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
This product has been evaluated for use in locations adhering to the current Florida Building Code.
See Installation Instructions NCTL210-3896-1-FBC, signed and sealed by Hermes F. Norero, P.E. (FL#
73778) for specific use parameters.
1. This product has been evaluated and is in compliance with the current Florida Building Code,
including the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Section 1609.1.2 of the current Florida Building Code and does not require an impact
resistant covering.
4. Site conditions that deviate from the details of drawing NCTL210-3896-1-FBC require further
engineering analysis by a licensed engineer or registered architect.
5. See Installation Instructions NCTL210-3896-1-FBC for size and design pressure limitations.
Hermes F. Norero, P.E.
Florida No. 73778
Page 2 of 4
BUILDING DROPS Rate: 0015
Report Noo:: 3101
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Quality Assurance: .The manufacturer has demonstrated compliance of products in accordance with the
Florida Building Code for manufacturing under a quality assurance program audited
by an approved quality assurance entity through National Accreditation &
Management Institute (FBC Organization #: QUA1789). -
Performance Standards: The product described herein has been tested per:
• TAS 201-94
• TAS 202-94
• TAS 203-94
Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories, Inc.
(FBC Organization # TST1589)
Report #: NCTL 210-3896-1, Report Date: 11/22/13
2. Certification Agency
National Accreditation & Management Institute
(FBC Organization #: CER1773) -
3. Material Certification
Miami Dade RER — Product Control Section NOA
E.I. DuPont De Nemours & Co., Inc.: PVB Interlayer
4. Material Certification
Miami Dade RER — Product Control Section NOA
Quanex Building Products: PVC Extrusions
Hermes F. Norero, P.E.
Florida No. 73778
Page 3 of 4
BUILDING DROPS Date: °31015
Report Noo:: 3101
- /J/26A\\ A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Installation: 1. Approved anchor types and substrates areas follows:
Through Frame Installation:
A. For wood substrates use (1) #10 Wood Screw type anchor per location of sufficient
length to achieve a minimum embedment of 1.50" into the wood substrate.
Nail Fin Installation:
B. For concrete or masonry substrate where one by (1X), non-structural, wood bucking is
employed, use (1) 3/16" diameter ITW Tapcon type concrete screw anchors per loation
of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry.
C. For concrete or masonry substrate where wood bucking is NOT employed, use (1) 3/16"
diameter ITW Tapcon type concrete screw anchors per location of sufficient length to
achieve minimum embedment of 1.25" into concrete or masonry.
D. For steel substrate, use (1) #10 Tek Screw type steel frame anchors per location of
sufficient length to achieve minimum three threads of penetration beyond steel
structure.
A. For wood substrates use (1) #10 Wood Screw type anchor per location of sufficient
length to achieve a minimum embedment of 1.50" into the wood substrate.
Refer to Installation Instructions (NCTL210-3896-1-FBC) fo.r anchor spacing and more details of the
installation requirements.
Design Pressure:
Design Pressure
Positive 50 PSF
Negative 55 PSF
Hermes F. Norero, P.E.
Florida No. 73778
Page 4 of 4