Loading...
HomeMy WebLinkAbout217735-1d Compaction signedHeadquarters 1W C IL � ENGINEERING Mailing 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958 1 %% AND TESTING Sebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.# 5693 Sanford, FL. 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net DATE TESTED: PERMIT #: CONTRACTOR: JOB LOCATION: September 27, 2021 Adams Homes 5323 Lugo Street Lot 46, Section 1 Waterstone Fort Pierce, Florida KSM JOB #: 217735-1d/BS/jam NUC # 528 Nuc Model: MC-IDR-P Nuc Serial #: MD049528 ITEM TESTED: Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1 S.W. 0" - 12" 45 107.5 108.5 99.1% 2 N.W. 106.9 98.5% 3 Center 108.3 99.8% 4 N.E. 108.0 99.5% 5 S.E. 107.7 99.3% Soil Description: Brown Sand In Place Moisture: 10.2 % Proctor Optimum Moisture: 12.0 % Proctor Max. Dry Density: P.C.F. 108.5 110.0 W I I I I I I I E I 109.0J_..�.._..I _..T.._,._..�..�.._.._.._ � � I I I I I H 108.0 T I I I I I 107.0 t— J.._.1_..-L I._..L..J.. I_.._ P I I I I I I I C 106.0 �..�.._.I_.. _1._..l..-4.._. _.._ i I I I I I I @ Test Locations the Density & F 1050:— 1_"t"—I'—"r"—i (—"- Penetrometer readings indicate the I I I I I I I I Degree of Compaction Meets 104.0 ,— — — - Minimum Requirement D 1 I—' T' —I —"r I—' for Staked Foundation R I I I I I I I 103.0..�.._.i_..t.._�._..r..�.._.�_..� Respectfully Submitted: Y 7 8 9 10 11 12 13 14 15 Digitally Moisture - % of Dry Weight signed by Thk Rem M1azbeenelem°nicallys.g dand Julie Keller Disclaimer: Contractor is responsible to maintain the tested area sealed dY lWle Keller, P.E. FL 11 the date stared ,r—ly—h—ghl.-g, in the condition that KSM completed the indicated passed dlgltzj"_'.re. Date: PIM"d compaction test. KSM is not responsible if the tested area has o�A—d signed and sealed and the =lgnat",—tb,—fied°nznVeectr°^.a 2021.09.28 °P1P5 been altered from the approved inspected condition. 11:57:30 -04'00' Julie E. Keller, P.E. President PE# 68366 9/28/2021 Email to: grant.thurston@adamshomes.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE