ITEM TESTED: Metal Building Pad
TEST LOCATION PEN DRY MAX. DRY PERCENT
OF SAMPLE DEPTH READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION
1. N.E. 0" -12"
2. S.E. "
3. Centerr "
4. N.W. "
5. S.W.
Soil Description:
Light.Brown sand with
Crushed Concrete
In Place Moisture:
10.8%
Proctor Optimum Moisture:
11.0%
Proctor Max. Dry Density: P.C.F.
115.4
@ Test Locations the Density &
Penetrometer readings indicate the
Degree of Compaction Meets
Minimum Requirement
for Unstaked Foundation
Respectfully Submitted:
�
.`�Q' . •`BEN
F
v
=A�.
N° .81
W
.
SIX
,
Z
.�#.
V.P. of Engineering
PE # 81439 4/24/2020
Email to: nickmacias7l@gmail.com
55+ 113.5 115.4
98.4%
It
114.0 "
98.8%
" 114.7
99.4%
" 113.9
98.7%
" 114.5
99.2%
Moisture - % of Dry Weight
Disclaimer: Contractor is responsible to maintain
the tested area in the condition that KSM
completed the indicated passed compaction test.
KSM is not responsible if the tested area has been
altered from the approved inspected condition.
RECEIVED
SEP 21 2021
�1? Ndeie.County
Proudly Serving Florida since 2990