Loading...
HomeMy WebLinkAboutSoil Compaction ReportHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 DATE TESTED: PERMIT #: CONTRACTOR: JOB LOCATION: t ENGINEERING A% AVL AND TESTING SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 April 23, 2020 Nick Macias 1840 Copenhaver Road Fort Pierce, Florida Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB #: 201891-1d/CH/jo NUC # 417 Nuc Model: 3500 Nuc Serial # 3417 ITEM TESTED: Metal Building Pad TEST LOCATION PEN DRY MAX. DRY PERCENT OF SAMPLE DEPTH READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1. N.E. 0" -12" 2. S.E. " 3. Centerr " 4. N.W. " 5. S.W. Soil Description: Light.Brown sand with Crushed Concrete In Place Moisture: 10.8% Proctor Optimum Moisture: 11.0% Proctor Max. Dry Density: P.C.F. 115.4 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: � .`�Q' . •`BEN F v =A�. N° .81 W . SIX , Z .�#. V.P. of Engineering PE # 81439 4/24/2020 Email to: nickmacias7l@gmail.com 55+ 113.5 115.4 98.4% It 114.0 " 98.8% " 114.7 99.4% " 113.9 98.7% " 114.5 99.2% Moisture - % of Dry Weight Disclaimer: Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. RECEIVED SEP 21 2021 �1? Ndeie.County Proudly Serving Florida since 2990