Loading...
HomeMy WebLinkAboutCompaction testUES Project No: Workorder No: Report Date: 3360.1900069.0000 246730-1 09/29/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:RJM CUSTOM HOMES, INC.UES Technician:Mark Rogers 6917 Vista Parkway North, Suite 1 West Palm Beach, FL 33411 Date Tested:09/28/2021 Project:RJM CUSTOM HOMES Various Locations, , County, FL Type of Test: Area Tested:9640 Fairwood Ct, PSL Field:ASTM D-6938 Nuclear Gauge Method Material:Backfill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Fill The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 Northeast corner of lot 0-1 ft 112.5 11.1 108.7 10.7 97 Pass 2 Southwestcorner of lot 0-1 ft 112.5 11.1 107.9 10.6 96 Pass 3 Center of lot 0-1 ft 112.5 11.1 109.0 10.6 97 Pass Remarks: Permit # 2102-0600 Reviewed By GFA International, Inc FBPE Registry No.4930 Thomas Dominic Montano Branch Manager STATE OF FLORIDA Professional Engineer No. 84146 This item has been digitally signed and sealed by Thomas Dominic Montano on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1